MAINTENANCE ENGINEERING ORDER

(AMCOM Reg. 750-2)

MEO NO.

DATE 15-JAN-2014 PAGE 1 of

TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:

Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°

APPLICABILITY CSI Critical Characteristic Affected?

Impact Statement Attached?

REFERENCES FOR RDECOM USE ONLY

DOCUMENT(S) AFFECTED

PURPOSE OR PROBLEM

PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE

MED FORM 15-DEC-09 1401-R-E

P 6649 Rev A

IUID Data Plate Marking For Anti-Icing Bleed and Start Valve P/Ns 4046T28G03, -05, -06, -14, -15, -16

Administrative

INTERIM USE OF THIS MEO IS AUTHORIZED

UNTIL AFFECTED DOCUMENT IS UPDATED.

MEO CHANGE TYPE

4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY

T700 DAN

DMWR 55-2995-231 dtd 15 May 1983 TN 111503A 10/18/2013

MEC E173434 10/10/2013

DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None

Add "USNAVY" to "Record as SET 1" Requirements (MEC E173434), relocate IUID data plate (MEC 174011) and update DMWR with new IUID Boilerplate UII Query Language

BENNETT.JENNI

FER.HILLER.129

5929045

Digitally signed by

BENNETT.JENNIFER.HILLER.1295929045

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=BENNETT.JENNIFER.HILLER.1295929 Date: 2014.01.13 14:59:11 -06'00'

Jennifer Bennett

NOLL.GERALD.S

TEVEN.12311769

Digitally signed by

NOLL.GERALD.STEVEN.1231176922

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=NOLL.GERALD.STEVEN.1231176922 Date: 2014.01.14 09:59:21 -06'00'

Steve Noll PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT

CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

ADD the following to the List of Illustrations:

"Figure 1-2: ..........Anti-Icing Bleed and Start Valve Data Plates Figure 1-3: ...........Item Unique Identification (IUID) Data Plate"

REVISE the paragraph to read as follows:

"1-5. Data Plates. The Anti-Icing Bleed and Start Valve has an identification plate (para 3-26) which contains the following information:"

ADD paragraphs 1-5.1, 1-5.2 and 1-5.3 and sub-paragraphs as follows:

"1-5.1. Item Unique Identification (IUID) Data Plate (Figure 1-2). The IUID Data Plate provides Machine Readable Information (MRI) in a compliant ECC 200 2-D data matrix that is encoded with a Construct 1 or 2 Unique Item Identifier (UII) using applicable Data Identifiers (DI) or Text Element Identifiers (TEIs) as data qualifiers in accordance with MIL-STD-130. In addition to the UII, other pertinent component information can be encoded in the 2-D data matrix preceded by the applicable data qualifier.

iii

1-3

1-5

1-5.1 1-5.2 1-5.3

Formatted Cont. Sheet

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

a. There are two possible formats for information marked on an IUID data plate and encoded in the 2-D data matrix:

(1) Manufacturer IUID Data Plate. Currently not available. Pending Original Equipment Manufacturer (OEM) Non-Recurring Engineering (NRE) completion.

(2) Legacy IUID Data Plate (Figure 1-2). The IUID data plate contains two 2-D data matrices. One data matrix is encoded with a Construct 1 UII that uses TEIs, SPL (supplier's CAGE code) and UCN (supplier's unique component number) as data qualifiers. The second data matrix is encoded with the item's PNR (current part number). The PNR being GE's part number upon completion of the Maintenance and Overhaul (M&O) event.

1-5.2. IUID Data Plate Fabrication (Figure 1-3). Prior to fabrication of the IUID data plate, the Department of Defense (DoD) IUID Registry shall be queried per paragraph 3-4.1.1.

a. The Anti Bleed Start Valve IUID data plate is fabricated out of adhesive backed black matte anodized aluminum material that meet the physical requirements per MIL-DTL-15024, Type L.

NOTE

The PNR to be marked on the data plate and encoded in the 2-D data matrix, is the final GE part number upon completion of M&O event.

b. The MRI and Human Readable Information (HRI) shall be marked on the IUID Data Plate using an Epilog Laser Marking System (table 2-2), Metal Photographic or other acceptable marking technique in accordance with

MIL-STD-130.

c. If the component does not have a IUID data plate or it has an UII that is not registered or not registered correctly in DoD IUID Registry per paragraph 3-4.1.1, then an IUID data plate shall be fabricated per steps b, c and the following:

(1) A Construct 1 UII shall be encoded into a 2-D data matrix IAW the DoD Guide to Uniquely Identifying Items and/or MIL-STD-130. The UII can be constructed by the overhaul/repair facility using one of the following methods:

(a) Use the overhaul facility's SPL (CAGE) and UCN or

(b) Generate using AMCOM's The Army Maintenance Management System - Aviation/Maintenance Consolidated Database System (Appendix A, Websites).

(2) The item shall be registered in the DoD IUID Registry (Appendix A, Websites) in accordance with the data submission procedures at the Defense Procurement and Acquisition Policy website (Appendix A, Websites).

P 6649 Rev A

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

1-3 (cont) 1-5.2 (cont)

(3) The following shall be recorded in the "Mark Section" of the DoD IUID Registry (Appendix A, Websites) in accordance with the Guidelines for Registering Government Serialization, Type Designation and Ownership of Major End Items, Assemblies and Subassemblies and Capital Equipment, in the DoD IUID Registry:

Record as SET 1:

1. Manufacturer Serial Number (minus any spaces).

2. National Stock Number (with dashes).

3. Type Designation - "UH-60" (with dash and caps)

4. Service/Agency/Command “USARMY" or "USNAVY" (no space, all capital letters)

5. UII

Record as SET 2:

Item GE P/N (As marked on item and/or original identification data plate) Item GE CAGE Code (As marked on item and/or original identification data plate)

Record as SET 3 (If applicable):

Item Vendor P/N (As marked on item and/or identification data plate) Item Vendor CAGE Code (As marked on item and/or identification data plate)

d. If the item has an MRI UII via an IUID data plate and meets the query requirements per para 3-4.1.1 and meets the readability criteria in paragraph 1-5.3 step (5), it does not need to be replaced. However, if it is damaged or the information is illegible or needs to be updated, then a data plate shall be fabricated per steps b and c, using the data found in the DoD IUID Registry record.

e. After the IUID data plate is fabricated and marked, use a Trucheck 401-R Kit Verifier (table 2-2) or an equivalent to verify that the 2-D data matrix has a minimum print quality grade per MIL-STD-130. Validate that data encoded in the 2-D data matrix matches HRI. Repeat the applicable marking process until the minimum print quality grade has been achieved.

P 6649 Rev A

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

1-3 (cont) 1-5.3 1-5.3. IUID Data Plate application:

WARNING

Isopropyl Alcohol TT-I-735

• Flammable - do not use near open flames, near welding areas or on hot surfaces.

• Do not smoke when using it and do not use it where others are smoking.

• Inhalation of vapors can cause drowsiness, dizziness and headache.

Contact of liquid with skin may cause dermatitis and irritation.

• If any liquid contacts skin or eyes, immediately flush affected area thoroughly with water. Remove solvent-saturated clothing. If vapors cause drowsiness, go to fresh air.

• When handling large quantities (greater than one gallon), work at air-exhausted workbench or covered tank.

• Store solvent and dispose of liquid-soaked Isopropyl alcohol is flammable and poisonous. Do not breathe the fumes. Put on a respirator. Use it only with sufficient external airflow. Keep it away from heat, sparks or an open flame. If it touches your skin or eyes, immediately flush them with water for a minimum of 15 minutes.

NOTE

Quality control shall inspect the IUID data plate to ensure proper application and that the HRI and MRI match the previously recorded data for that component.

(1) Clean the IUID data plate application area on the component using cloth (item 38, Appendix C) moistened with isopropyl alcohol (item 1.3, Appendix C).

Ensure all oils and solids are removed from application area.

(2) Prior to application, ensure that the IUID data plate data is correct for the component to which it will be applied.

(3) Peel liner from IUID data plate. Avoid adhesive contact with fingers. Place data plate on the application area and firmly press from the middle out using a roller or a cloth (item 38, Appendix C) to ensure 100% contact to remove any air bubbles.

(4) Apply a coating of clear polyurethane (item 37, Appendix C) or overcoat 683-3-20 (item 39, Appendix C) or an equivalent with a foam brush (item 36, Appendix C). The coating shall completely cover the IUID data plate and extend a minimum of 1/4 inch uniformly around the edges of the label. Let Dry.

(5) Using a hand held data matrix reader (table 2-2) or an equivalent, check the readability of the 2-D data matrices on the IUID Data Plate by scanning 2 times.

The time to decode any two scans shall be 15 seconds or less. Replace the data plate if one of the two data matrices does not meet the readability criteria.

Validate that all pertinent information required in the 2-D data matrix matches the information for that component.

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

1-3 (cont)

2-2

3-1

3-4.1.1

1-2

1-3

2-2

ADD new figure found on page 10 of this MEO.

ADD new figure found on page 11 of this MEO after figure 1-2.

ADD the following items:

"Nomenclature: Epilog, HELIX - 45 watt, CO2 Mini Laser Marking System NSN or Part NO: L24EX-45 (1RJS7) or equivalent Reference Paragraph for use: 1-5.2

Nomenclature: Reader, MS-Q Handheld NSN or Part NO: FIS-6100-0011 (0F5R7) Reference Paragraph of Use: 1-5.3.(5), 3.4.1.1

Nomenclature: Verifier, TruCheck 401-R Kit NSN or Part NO: 2537 (1SNG2) Reference Paragraph of Use: 1-5.2.e"

INSERT a new paragraph, notes, headings and sub-paragraphs, to read as follows:

"NOTE

Do not remove IUID data plate(s) unless necessitated by damage, maintenance requirements or determination that the item does not meet the criteria below.

NOTE

Protect the IUID data plate(s) that remains on the item during cleaning, maintenance processes and painting.

3-4.1.1 DoD IUID Registry Query. The DoD IUID Registry and/or AMCOM's TAMMS-A/UID database, shall be queried to determine if the component has been assigned a UII.

a. Inspect the Anti-Icing Bleed and Start Valve for the presence of a 2-D data matrix via an IUID data plate (Figure 1-3), or other IUID label media. If present, use a handheld data matrix reader (see Table 2-2) or an equivalent to scan the 2-D data matrices. If the scan is successful, proceed to paragraph 3-4.1.1.d and/or 3-4.1.1.e. If the scan is not successful after two attempts, proceed to paragraph 3-4.1.1.b.

WARNING

Isopropyl alcohol is flammable and toxic to eyes, skin, and respiratory tract.

Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well ventilated areas (or use approved respirator as determined by local safety/industrial hygiene personnel). Keep away from open flames, sparks, or other sources of ignition.

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

b. Clean the 2-D data matrices with a clean, lint-free towel (item 38, Appendix C) moistened with isopropyl alcohol (item 1.3, Appendix C) and scan again. If the third scan is successful, proceed to paragraph 3-4.1.1.d or 3-4.1.1.e. If the third scan is not successful, use the HRI to query the DoD IUID Registry (see paragraph 3-4.1.1.d.(2)) and/or TAMMS-A/UID database (see paragraph 3-4.1.1.e.(2)).

c. If neither OPM IUID Label(s) nor IUID data plate(s) are present (only an original nameplate), query the DoD IUID Registry (see paragraph 3-4.1.1.d) and/or TAMMS-A/UID database (see paragraph 3-4.1.1.e).

d. Query the DoD IUID Registry (see Appendix A, Websites) as follows:

(1) DoD IUID Registry home page, select “Queries”, then “Single Item Query” and place the scanned/recorded UII data into the “UII*” field. If the query returns a record, proceed to paragraph 3-4.1.1.f. If the query does not return a record proceed to 3-4.1.1.d.(2) below.

(2) Using the human readable manufacturer serial number on the component (may be indicated by SER, Serial No., Ser No., S/N, SN, SER, SEQ, etc.), query the DoD IUID Registry. Select “Queries,” then “Mark Query”. Place “SERIAL NUMBER” in the “Mark Content” field and place the human readable manufacturer serial number (as visible on the component, minus any spaces) in the “Mark Value” field. If the registry record data matches the component data exactly, proceed to paragraph 3-4.1.1.f. If the query does not return a record (i.e., did not have a registered UII), an IUID data plate(s) shall be fabricated IAW paragraph 1-5.2.

e. Query the TAMMS-A/UID database (see Appendix A, Websites) as follows:

(1) TAMMS-A home page, select `''Apps”, then “UID” from the drop down menu, and place the scanned/recorded UII data into the “UII” field. If the query returns a record, proceed to paragraph 3-4.1.1.f. If the query does not return a record proceed to 3-4.1.1.e.(2) below.

(2) Using the human readable manufacturer serial number on the component (indicated by Serial No., Ser No., S/N, SN, SER, (S), SEQ, etc.) query the TAMMS-A/UID database by placing the serial number in the “SER” field. The query may return multiple records. Use the additional data from the component (component description, part number, etc.) to determine if one of the database records can be matched to the component. If a database record matches the component data exactly, proceed to paragraph 3-4.1.1.f. If no database record can be matched exactly to the component data, (i.e., did not have a registered UII), an IUID data plate(s) shall be fabricated IAW paragraph 1-5.2.

f. Record Data.

(1) Ensure the data in the DoD IUID Registry and/or TAMMS-A/UID database record matches the component data (resident on the Anti-Icing Bleed and Start Valve or within its accompanying historical records). If all data matches, record all pertinent component data required to fabricate the IUID data plate (UII Data Elements, GE PN and all other data requirements resident on the component and/or in the registry record). It is necessary that all recorded data be matched to the same end item, assembly, or component on which they were found during

PSA.

(2) If the data in the DoD IUID Registry and/or TAMMS-A/UID database record does not match the component data, refer to paragraph 1-5.2 for IUID data plate fabrication."

P 6649 Rev A

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

3-9

3-10

3-13

3-14

3-39

3-61

4-19

4-25

3-30

3-56

4-21.nn

4-33.1

REPLACE Figure with new figure found on page 12 of this MEO.

ADD the following before item 3-1 under DESCRIPTION:

"a - U/O 73414-2 b - U/O 79047-1 c - U/O 89102-1"

ADD for item 58 and for part number 79047-1 under units per assy, "N".

ADD an additional item 58 as follows:

"58"..."89102-1"..."1PVC5"..." . DEFLECTOR ASSY"..."1"..."blank".

ADD "a" for item 61, part number 73414-1 under usable on code.

ADD "b" for item 61, part number 79047-2 under usable on code.

ADD an additional item 61 as follows:

"61"..."89102-2"..."1PVC5"..."DEFLECTOR"..."c"..."1".

ADD item 61A as follows:

"61A"..."MS16555-604"..."96906"..."PIN"..."c"..."1".

ADD item 94 as follows:

"FIGURE & INDEX NUMBER: 94

PART NUMBER:

DESCRIPTION: Item Unique Identification (IUID) Data Plate (local fabrication)

UNITS PER ASS'Y: 1"

CHANGE dimension at bottom of drawing from "0.037" to "0.0037".

CHANGE to read as follows:

"3-56. Deflector Assembly and Setscrew Adhesion Instructions for p/n 73414-2 & 79047-1."

CHANGE paragraph to read as follows:

"nn. Upon completion of test, secure setscrews (59) in deflector (61) (para 3-56 for p/n 73414-2 & 79041-1. For p/n 89102-1 proceed as follows.

(1) Force Isopropyl Alcohol between the set screws (59) and deflector (61) with a squeeze bottle to remove contaminates. Set screws are not removable.

(2) Blow dry the part with clean, dry compressed air. Verify the deflector and set screw are dry and free of contaminates.

(3) Apply 1 drop of retaining compound (item 12.1.1, Appendix C) to the threads.

This retaining compound should wick around the threads. Remove any excess.

Insure that the port is free of retaining compound.

(4) Retaining compound will cure in 24 hours. To expedite curing, apply localized hot air to setscrew,or place the unit in an oven for 1 hour at 250 degrees F.

INSERT new paragraphs as follows:

"4-33.1. Item Unique Identification (IUID) Data Plate.

a. If the IUID data plate was removed, refer to paragraph 1-5.2 IUID data plate Fabrication".

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

5-1

A-1

A-1

5-5

Appx A

ADD a new paragraph c, to read as follows:

"c. The Quality Inspectors (QI) shall inspect the IUID data plate to ensure proper installation and that the HRI and MRI matches the previously recorded information for that component."

ADD the following references to Appendix A:

Specifications:

"MIL-DTL-15024: Detail Specification, Plates, Tags and Bands for Identification of Equipment, General Specification for

MIL-PRF-22750: Military Specification, Coating, Epoxy, High Solids

MIL-PRF-85285: Performance Specification, Coating, Polyurethane, Aircraft and Support Equipment

Military Standards:

MIL-STD-130: Department of Defense Standard Practice Identification Marking of U.S. Military Property

ASTM B 209: Standard Specs for Aluminum and Aluminum-Alloy Sheet and Plate"

Other Media:

GG-P-455: Plate and Foil, Photographic (Photosensitive Anodized Aluminum)

ISO/IEC 15415: Information Technology - Automatic Identification and Data Capture Techniques - Bar Code Print Quality Test Specification

DoD Guide: Department of Defense Guide to Uniquely Identifying Items

DoD Guide: Guidelines for Registering Government Serialization, Type Designation and Ownership of Major End Items, Assemblies and Subassemblies and Capital Equipment

AS9132: (R) Data Matrix Quality Requirements for Parts Marking

ISO 15434: Information Technology - Transfer Syntax for High Capacity ADC Media"

ADD a new reference section to Appendix A named "Websites" and list the following:

TAMMS-A/MCDS: The Army Maintenance Management System - Aviation/Maintenance Consolidated Database System https://tamms-a.redstone.army.mil

DPAP UID: Defense Procurement and Acquisition Policy http://www.acq.osd.mil/dpap/pdi/uid/data_submission_information.html

DoD IUID Registry: Department of Defense IUID Registry https://iuid.logisticsinformationservice.dla.mil

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

B-8

B-10

C-2

C-4

B-1

REPLACE Figure with new figure found on page 13 of this MEO."

ADD a new item in the "NOT USED" item slot (37) as follows:

"SMR CODE: MDDDZ

NSN: (blank); PART NUMBER: (blank); CAGE: (blank) DESCRIPTION: Data Plate, Item Unique Identification (IUID) (Local fabrication) USABLE ON CODE: (blank); QTY: 1"

CHANGE item 58 as follows:

"58"..."PADZZ"..."2995-01-144-0003"..."89102-1"..."1PVC5"...". DEFLECTOR

ASSY"..."blank"..."1".

CHANGE item 61 as follows:

"61"..."XADZZ"..."NSL"..."89102-2"..."1PVC5"..."DEFLECTOR"..."blank"..."1".

ADD item 61A as follows:

"61A"..."XADZZ"..."NSL"..."MS16555-604"..."96906"..."PIN"..."blank"..."1".

ADD the following items to Expendable Supplies and Materials:

"ITEM NO.: 12.1.1

NSN: 8030-00-111-2763

DESCRIPTION: Loctite, 290, Retaining Compound (05972)

U/M: BX

ITEM NO.: 36

NSN:

DESCRIPTION: Foam, Brush (1HEN9), A52081 or equivalent

U/M: EA

ITEM NO.: 37

NSN:

DESCRIPTION: Coating Polyurethane, MIL-STD-85285, Type 1, Class H

U/M: KT

ITEM NO.: 38

NSN: 7920-00-401-8034

DESCRIPTION: Cloth, Cleaning, CCC-C-46 (81348)

U/M: BX

ITEM NO.: 39

NSN:

DESCRIPTION: Overcoat, 683-3-20, (0KXA5, AKZO Nobel Aerospace Coatings, Waukegan, IL)

U/M: KT"

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

ITEM UNIQUE IDENTIFICATION

(IUID) DATA PLATE

IDENTIFICATION DATA PLATE

V A

L V

E , A

I S

B

P A

R T

N O

. 8

-4

T

G

V

C

C O

P A

R T

N O

-1

E R

IA

L

N O

H

V

C

C O

IN

D

U S

T R

IE

O U

T H

E L

M O

N T

E , C

A L

IF

O

R N

IA

M F

G C

A G

E C

O D

E N

O . 1

P V

C

O N

T R

A C

T N

O . S

P R

R A

-1

-D

-0

N

TI

-IC

IN

G

B

LE

ED

A

N D

S

TA

R T

VA

LV

E

PN

R

6T

XX

X

SP

L

X

XX

U

N X

XX

XX

Figure 1-2. Anti-Icing and Bleed Start Valve Data Plates.

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

NOTES:

1. All Dimensions in inches. Drawing not to scale.

2. Font lettering and size per MIL-STD-130. Font locations are approximate.

3. Physical characteristics and test requirements per MIL-DTL-15024, Type L.

4. Material: Black matte anodizes aluminum .003 to .005 thickness, with 9485PC adhesive tape

(3M) or equivalent. Black anodizes plates shall be completely coated with a clear matte poly-urethane material per MIL-PRF-85285 or an equivalent and extend a minimum of 1/4- inch around the edges.

5. The 2-D data matrix symbol shall be compliant to ECC 200 in accordance with ISO/IEC 16022.

6. Quiet Zone (Free Space) around the 2-D data matrix code shall be .050 MIN. in all directions.

7. Marking edge distance to be a minimum of .060.

8. The recommended part mark size for the 2-D data matrix symbol is 0.20 to 0.50 inch square.

The 2-D data matrix symbol shall not be larger that 1.00 inch square.

2-D data matrix encoded with a Construct 1 UII using TEIs SPL (supplier’s CAGE Code) and UCN (supplier’s item unique component number).

The 2-D data matrix to contain General Electric’s (GE’s) component PNR (part number upon completion of the M&O event).

ANTI-ICING BLEED START VALVE

SPL XXXXX

UCN XXXXXXXXXXXX

PNR 4046T28XXX

.750

1.25

.09 R TYP

4 PLS

ANTI-ICING BLEED START VALVE

SPL XXXXX

UCN XXXXXXXXXXXX

PNR 4046T28XXX

Figure 1-3. Item Unique Identification (IUID) Data Plate

P 6649 Rev A

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

Figure 3-1. Anti-Icing Bleed Start Valve, Exploded View (Sheet 3).

P 6649 Rev A

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

Figure B-1. Anti-Icing Bleed and Start Valve (Sheet 3).

P 6649 Rev A

RDMR-AEM

MEMORANDUM FOR RECORD:

SUBJECT: Impact of AED Maintenance Engineering Order (MEO) on maintenance using ,affecting system:

Enclosed MEO is issued by this office and is provided as part of our Technical Data user support mission.

4. THIS MEO CHANGES THE FOLLOWING (Check all that apply):

1.

Consumables

Materials

Expendables

Repairable Bill of Materials (RBOM)Impact

3. PRIORITY IMPLEMENTATION CATEGORY :

6. Comments:

7. Point of contact for this action is

2. FOR AMCOM ACQUISITION CENTER USE ONLY:

This MEO was written as a request from a contractor/KO on an active M&O contract.

Request that MEO be transmitted to the contractor as soon as possible.

b.Items checked in this area are considered Normal Priority Implementation Category.

Illustrated Parts Breakdown Change Mandatory Replacement Part

TSO/TSN Change Configuration Change

Publication New Change

Hardware Tooling Equipment

New/Revised Procedure/Process

Process Improvement Project Inspection

Special Process Testing Cost Savings a.Items checked in this area are considered High Priority Implementation Category.

5. Reason(s) MEO Written:

Other

Other

P 6649 Rev A

DMWR 55-2995-231 dtd 15 May 1983 T700

P 6649 Rev A

4) Normal - Can be implemented with normal priority

Parts Marking Implementation/Update

Add "USNAVY" to "Record as SET 1" Requirements (MEC E173434), relocate IUID data plate (MEC 174011) and update DMWR with new IUID Boilerplate UII Query Language

Jennifer Bennett (RDMR-AEM Engineering, 361-961-3543) or Dave Stark (Camber Corporation) 361-961-1359

BENNETT.JENNIFER.HILLER.1295929045

Digitally signed by BENNETT.JENNIFER.HILLER.1295929045 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=BENNETT.JENNIFER.HILLER.1295929045 Date: 2014.01.13 14:57:57 -06'00'

Jennifer Bennett

File details come from the government source that posted it. Updated .