MAINTENANCE ENGINEERING ORDER
(AMCOM Reg 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances
Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional………..…….+/- 1/32 Decimal……….………..+/- .010 Angular…………+/- ½ degrees
APPLICABILITY
INTERIM USE OF THIS MEO IS AUTHORIZED UNTIL
AFFECTED DOCUMENT IS UPDATED.
CSI Critical Characteristic Affected?
Impact Statement Attached:
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
DOCUMENT CHANGE IS REQUIRED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT CHANGE OR
REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP
NO.
PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGE MUST BE GIVEN)
MED FORM 15-DEC-09 1401-R-E
P6575 Sep 1, 2011 1
Addition of MIL-PRF-680 as Alternative Cleaner for Vacco AI Valve
NO
✔ YES
DMWR 55-2995-231 DATED 15 May 1983
T700I DAX
TTS 101478
To allow the use of MIL-PRF-680 as shown in this MEO
Gabriel Alaniz Mike Vourcos Steve Noll
3-33
3-33
3-33
C-4
3-18.a.1
3-18.b.
3-18.c.
Add the following paragraph:
"a.1 Alternate method for cleaning disassembled metallic parts. Place disassembled parts in a basket and wash in a cleaning tank using cleaning solvent ( Item 35, Appendix C)
After washing off any debris or dirt on parts, immerse basket in cleaning solvent(Item 35, Appendix C) for one to two minutes. Remove basket from cleaner and allow parts to air dry. Using low pressure compressed air, blow any accumulated liquid from holes and orifices. "
Change "same solvent" to "Isopropyl Alcohol, Item 27.1, Appendix C)"
Change "solvent" to "Isopropyl Alcohol, Item 27.1, Appendix C)"
Add new Item "35", NSN "6850-00-274-5421", Description "Solvent, Dry Cleaning, MIL-PRF-680", UM "GL"
RDMR-AEM
MEMORANDUM FOR RECORD:
SUBJECT: Impact of AED Maintenance Engineering Order (MEO) on maintenance using , dated , affecting system:
1. Enclosed MEO will be issued by this office and is provided as part of our Technical Data user support mission. This MEO may impact maintenance contracts or repair parts acquisition decisions.
2. OVERALL IMPACT:
3. CLASSIFICATION:
New / Revised Procedure / Process Illustrated Parts Breakdown (IPB) Change
Technical Requirement Clarification Repairable Bill of Materials (RBOM) Impact
Suggestion Study / Test Results Critical Safety Item (CSI) Review
Parts Marking Implementation / Update Environmental Review
MEO Review (Chg. / Rev. Driven) Other
4. CRITICAL CHARACTERISTIC(S) AFFECTED:
Dimension / Tolerance Finish / Material Process / Procedure None
5. READINESS IMPACT:
Testing Required Special Tooling Special Process
Part / Material Logistics Impact Inspection(s) Required None
6. MATERIAL IMPACT:
More Less None Unknown Cost / Usage
Labor / Processing Parts / Materials Affected:
7. COMMENTS:
8. Point of contact for this action is
DMWR 55-2995-231
P6575
P6575
15MAY 1983 T700I
No Significant Airworthiness Impact-Implement per standard procedures
1349 requested approval to use MIL-PRF-680. Idea should be included in DMWR so MEO was created rather than simply approving 1379.
Gabriel Alaniz, gerbo.alaniz@us.army.mil, 361-961-4255
ALANIZ.GABRIEL.AL
BERTO.1279200248
Digitally signed by
ALANIZ.GABRIEL.ALBERTO.1279200248
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=ALANIZ.GABRIEL.ALBERTO.1279200248 Date: 2011.08.30 15:18:07 -05'00'