This document contains questions and answers regarding a solicitation for a media blasting booth system. The solicitation requests a two-operator media blasting booth to be installed inside at a Department of the Army Materiel Command facility. Reclaim equipment can be placed next to the indoor booth. Sand was specified as the required abrasive by the customer. Clarification was provided that ventilation collection and air makeup units would be located outside if the booth is indoor, and that an equipment room would be required beside an outdoor booth.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q1. They (SOW) say 2 nozzles. How Many operators 1 or 2?

A1. Two (2) operators

Q2. We need to clarify if booth will be installed inside or outside confusing statement on this.

A2. Booth will be installed inside

Q3. (Vendor believes they) Cannot use sand with this booth (but) can use other type of abrasive that are recyclable like steel grit, aluminum oxide, garnet. Please clarify.

A3. Sand was requested by our customer

Q4. "If booth is located inside we will not require an AMU as we will be returning air inside booth."

Please clarify.

A4. Please give details on returning the air into the booth.

Q5. "If located outside then we will need AMU to keep temperature comfortable for operator but will also require an equipment room beside the booth for all blast equipment and bucket elevator." Please clarify.

A5. Reclaim equipment can be placed next the booth inside the bay and the ventilation collection and AMU will be located outside.