37_ITEM 01.3-27_ADD 03_02700FA601.pdf
PDF 437 KB Posted
- Attached to
- F-35 THREE BAY SPECIALIZED HANGAR Federal contract opportunity
- Solicitation number
- W50S9F-22-B-0001
- Issued by
- Department of the Army National Guard
About this file
This solicitation is for an unrestricted invitation for bid to construct a new three-bay specialized hangar at Dane County Regional Airport-Truax Field in Madison, Wisconsin. The project scope includes demolishing an existing 19,875 square foot building and constructing a new 31,000 square foot hangar with three bays and associated administrative and shop spaces. The hangar bays must accommodate pre-conditioned aircraft air, 270VDC aircraft power, fire suppression, and HVAC. The facility will also require a lightning protection system, fall protection, and an Advantor security system. The base contract line item is for construction of the three-bay hangar. There are also two options that can be awarded: option one is for a paint/mix addition and option two is for aircraft-rated pavement. Interested contractors must register in the System for Award Management and can access solicitation documents on SAM.gov. A pre-bid conference and site visit will be held on a specified date at Truax Field. The bid opening will follow FAR procedures. The completion period is 550 calendar days. The estimated value is between $25-100 million. The soliciting agency is the Department of the Army National Guard.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACU
MONACO MAAP-X
ROOM 125
120VSPD
LOC
LOC
120B
MM MM
VS WF
125 125
WP-1
MM
VS
MM
PS
PA-1
MM
VS
MM
PS
PA-2
MM
VS
MM
PS
PA-3
RTU-01 DOAS-01
MMRSFACU - ALARM (FLAME DETECTOR)
MMRSFACU - PREACTION SYSTEM DISCHARGE
MMRSFACU - SUPERVISORY
MMRSFACU - PREACTION SYSTEM DISABLED
MMRSFACU - PREACTION SYSTEM TROUBLE
C WP
TYPICAL NAC CIRCUIT
ANTENNA
LED TEXT
SIGN
CONTROLLER101101101101
EOL
106 106 119 119
119120B128 128 128
MM
MM
MM
PS
L
PS
L
PS
L
MM
PS
H
MM
PS
H
MM
PS
H
SPDWATERFLOW
SPEAKER/ STROBE
W / WATERFLOW SIGN
SPD
(PROVIDE SURGE SUPPRESSION
FOR DEVICES ON BUILDING
EXTERIOR)
1. PROVIDE SURGE SUPPRESSION ON ALL 120 V POWER
SUPPLIES, ANTENNAS, AND CIRCUITS SERVING DEVICES
EXTERIOR TO THE BUILDING, INCLUDING PIV SUPERVISION
AND NOTIFICATION.
2. PROVIDE SMOKE DETECTION AND 120 V POWER FROM FA
CIRCUIT FOR ALL POWER EXTENDER PANELS.
3. PROVIDE ADDITIONAL DEVICES AND APPLIANCES WHERE
NECESSARY TO MEET THE REQUIREMENTS OF THE DESIGN
CRITERIA.
4. PROVIDE REMOTE KEYED TEST SWITCH WITH LED INDICATORS
MAX. 7' AFF AT EACH DUCT SMOKE DETECTOR.
5. ALL FA AND RELEASING SYSTEM DEVICES, APPLIANCES, TERMINAL
BOXES AND THEIR INSTALLATION IN THE HANGAR BAYS SHALL
BE NEMA 4, SUITABLE FOR WET LOCATIONS.
6. RISER DIAGRAM IS DIAGRAMATIC IN NATURE AND ALL CIRCUITS, DEVICES,
APPLIANCES AND EQUIPMENT REQUIRED FOR THIS DELEGATED DESIGN
ARE NOT SHOWN. PROVIDE ADDITIONAL DEVICES, APPLIANCES AND
EQUIPMENT WHERE REQUIRED BY REFERENCED CRITERIA, FOR
COMPLETE AND INTELLIGIBLE SYSTEM.
LOCATE IN 142 IF
OPTION #1 IS NOT
TAKEN
MAU-04
MM
EYEWASH
BID OPTION #1
LOCATE IN 142 IF
OPTION #1 IS NOT
TAKEN
NOTES:
CO
CO
CO
MM
VS
MM
VS
CO
CO
(OPTION
#1)
FFFF
101101101101 F
106126 F
F
119 119 F
120B146 128145 F
F F F F F
CM
CM
CM
CM
FIRE SHUTTERS
P113 P107
CM
HVLS SHUTDOWN
CM
CM
PA
MUTE
CM
CM
GAS SHUTOFF
CM
CM
CCU-02
CM
EF-07
CM
CM
EF-06 EF-03
CM
EHRU-01
CM
MAU-01
CM
CCU-01
CM
EF-04
CM
PCA-03
120B
CM
PCA-02
120B
CM
PCA-01
MM
VS
MM
VS
MM
MM
MM
MM
MM
MM
MM
AED
MM
EYEWASH
MM
VS
KNOX
BOX
KB
CM
HVU-01
CM
EF-09
CM
EF-10
CM
EF-11
WP
CO
(OPTION
#1)
126 144
ROOF ROOF
CM
EHRU-02
F
F
124125 F
128 128 F F
EXP
BFP#1 BFP#2
MM
VS
MMCONTAINMENT LEVEL-NOT EMPTY
MMCONTAINMENT LEVEL-HIGH LEVEL
MMMANUAL TRENCH DRAIN OUTFALL VALVE OPEN
MMMANUAL TRENCH DRAIN OUTFALL VALVE CLOSED
TRENCH DRAIN
OUTFALL
CONTAINMENT
AND MANUAL
VALVE MONITORING
PANEL
SPD
SPD
PIV
FAA
120B
MM
VS
MM
PIV
VS
SPD
FP ROOM
LOW TEMP
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\jtm \D o cum ents\M y R evit\02700_FP_jm o bbsXYN
BH
.rvt
6/15/2022 11:12 :54 AM
FIRE ALARM & MASS
NOTIFICATION SYSTEM RISER
DIAGRAM
FA601
LFO
JME
JME
SCALE:NTS
B3 FIRE ALARM & MASS NOTIFICATION SYSTEM RISER DIAGRAM
1 ADDENDUM 1 04/22/2022
2 ADDENDUM 2 06/08/2022
3 ADDENDUM 3 06/14/2022
W
IS C O NS IN
P R
O F
E
S S I O N A L
E N G
I N E
E R
LIANE F
OZMUN
E-48073
OKLAHOMA CITY
OK
File details come from the government source that posted it. Updated .