WALL TYPES-BI ADD_072922.pdf
PDF 50 KB Posted
- Attached to
- VTANG Replace B-120 Chiller Federal contract opportunity
- Solicitation number
- W50S9C-22-B-0004
About this file
This solicitation is for replacement of an 81-ton roof-mounted chiller on Building 120 at the Vermont Army National Guard. The project includes installing a new ground-mounted chiller and all associated electrical, mechanical and plumbing work to create a fully functioning system. Additional work involves modifying the flightline fence for construction access and providing redline drawings and operation/maintenance manuals. The solicitation was issued by the Department of the Army with responses due by the date listed on the Federal Business Opportunities website. The anticipated award date is included in the solicitation.
View the file
Other files for this federal contract opportunity
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
• PREFINISHED CORRUGATED METAL SIDING
• AIR INFILTRATION BARRIER
• NAILBASE INSULATION PANELS:
2" POLYISO INSULATION BOARD
BONDED TO 1/2" PWD SHEATHING
• 10" METAL STUDS @ 12" O.C.
• 1/2" RESILIENT CHANNELS HORIZONTAL @ 16" OC.
• 10" DENSE PACK CELLULOSE
• (2) LAYERS 5/8" FC GWB
EXG. EXT. WALL AT NE CORNER OF
SIMULATOR BAY ABOVE ROOF- STC-50 (SECURE)
(SPECIAL ACCESS PROGRAM FACILITY-SAPF)
1 1/2"=1'-0"2
STRUCT.
GRID
EXG. EXT. WALL AT NW CORNER
OF STORAGE BAY (NOT SECURE)
1 1/2"=1'-0"
• PREFINISHED CORRUGATED METAL SIDING
• AIR INFILTRATION BARRIER
• 5/8" PWD SHEATHING
• 1" RIGID INSULATION
• 8" METAL STUDS @ 16" O.C.
• 8" FG BATT INSULATION
• VAPOR RETARDER
• 5/8" GWB
| SK-1 [Sheet Title] |
| Viewport-1 |
File details come from the government source that posted it. Updated .