This solicitation package describes requirements for a firm fixed-price construction contract to repair water mains and roads at the 151st Air Refueling Wing, Utah Air National Guard base in Salt Lake City, Utah. The project scope includes construction of roads, curbs, gutters, sidewalks, replacing water mains and laterals, fire hydrants, and storm drains. Water meters and detector check valves will also be replaced. The base bid is for work on Mustang Lane and North Loop, with optional additional work on Patriot Way and Sabre Street. A brand name requirement is specified for a Hersey Model DC detector check valve. The projected value is between $5-10 million. The pre-bid conference is August 11th and bids are due August 31st. The contract period of performance is 365 days after notice to proceed. The set-aside is for small businesses under NAICS code 237110 with a $39.5 million size standard. The solicitation is available on betaSAM.gov and interested parties must monitor the site for amendments and information.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8/27/2020 UTANG Repair Water Mains & Roads
Environmental Concerns
CONTAMINATED SOIL
• Contaminated soil cannot be used as fill elsewhere. It must be sampled and disposed at approved landfill (regulation allows for return to site, but the project specs do not allow this)
• Contaminated soil would be disposed as non‐hazardous waste due to LUST site exemption found in 40 CFR 261.4(b)10 [Lab and Landfill Options] o For the Wasatch Regional Landfill, a sample must be taken and waste profiled (expect 3 day turnaround for lab and profiling before disposal); landfill can provide rolloff container at cost;
estimate disposal at $40/ton o Landfill Profile: Richard McMullin 801‐253‐1111 RMcMullin@republicservices.com o Lab: American West Analytical Services 801‐263‐8686 TCLP Metals, TCLP Volatile, TCLP
Semivolatile (confirm these with McMullin)
WATER
• Contaminated Zones: Contaminated water must be sampled and disposed off-site of according to federal, state, and local regulations for the type and quantity of contaminant.
• Non-Contaminated Zones: Rising groundwater can be pumped out and either returned to the site (no permit required) when finished or discharged to the storm drain with a Utah Groundwater Discharge permit (see permit section of Specs: 01 41 26).
o Contamination Disposal option: ET Technologies o Permit: Contact DEQ, Hillary Mason 801‐536‐4162 for initial assistance https://deq.utah.gov/legacy/programs/water‐quality/ground‐water/permits/index.htm#cuicp [Option]
KNOWN CONTAMINATION ZONE
• Workers must be notified of contaminated soil and groundwater:
o Ground water only: (Vinyl Chloride) (TCE) (Cis‐1,2‐DCE) (1,1‐DCE) o Soil & GW: (Benzene) (TPH‐G) (TPH‐D)
• See maps of IRP zones
• See map of IRP wells; well integrity must be preserved for seven known wells. Nine wells are expected in the zone. Two wells have not been located (ANGMW16‐B & ANGMW16‐C). If located, notify government. Government will evaluate and determine how to proceed.
PIPE MATERIAL IN CONTAMINATION ZONE
• Drinking Water standards apply; Utah Administrative Code R309‐550‐5(10); SLC public utilities does not use PVC in contaminated soil. Ductile Iron piping is required in contaminated areas. For details on locations and requirements, see Drawings and Specifications (particularly Mustang Dwgs G-04 Notes 46-48 and C-04) mailto:RMcMullin@republicservices.com https://deq.utah.gov/legacy/programs/water-quality/ground-water/permits/index.htm#cuicp https://deq.utah.gov/legacy/programs/water-quality/utah-underground-injection-control/resources.htm https://deq.utah.gov/legacy/programs/water-quality/utah-underground-injection-control/resources.htm https://rules.utah.gov/publicat/code/r309/r309-550.htm
Site ST008
UST-016MW
CLINTON AVE
N
W
2nd ST
W
3rd ST
Site SS002
MW-8
MW-7
MW-6
MW-12
MW-11
S2MW-2
S1MW-1
ANGMW-22 ANGMW-21
ANGMW-20
ANGMW-19
UST-012MW
S1/2MW-24
ANGMW-17C
ANGMW-17B
ANGMW-15C
ANGMW-15B
ANGMW-13C
ANGMW-13B
ANGMW-13A
MW-9
MW-5
MW-4
MW-2
MW-10
FPW-1
UST-011MW
S1/2MW-23
ANGMW-18C
ANGMW-18B
ANGMW-17A
ANGMW-16C
ANGMW-16B
ANGMW-16A
ANGMW-15A
\\Brookside\gis_share\ENBG\00_Proj\A\AirNationalGuard\UANG\MapFiles\GWR_2017_0815\Fig02-01_Wells.mxd JN025436 4/4/2018 16:13:06
Figure 2-1 Groundwater Monitoring Well Locations 151st Air Refueling Wing, Utah Air National Guard Salt Lake City, Utah
LEGEND
Monitoring Wells Gauged
Monitoring Wells Gauged and Sampled
Monitoring Wells Not Used
Area of Detected Impacts, September 2015
151st Air Refueling Wing Property
Site SS002 and ST008 Location
Building Number50
Service Layer Credits: Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GIS User Community
Note: ANGMW-14A/-14B/-14C destroyed by 2016 parking lot grading activities.
0 100 200 Feet
1 inch = 100 feet
1257626098N Rectangle
1257626098N Text Box Highlighted well was abandoned July 2020, no longer required to be preserved.
A
A
A A
A
A
FIRE STATION
UST-010MW
UST-008MW
UST-016MW
ANGMW-16A
UST-007MWa
UST-015MW
SLC \\slcdbp01\GIS\PROJECTS\UANG\MapFiles\GWR_2018_04\GW_mon_analys_result_Apr18.mxd JN025436 8/3/2018 11:10:48
FIGURE 3-3
Groundwater Monitoring Analysis Results - October 2018 151st Air Refueling Wing, Utah Air National Guard Salt Lake City, Utah
A Monitoring Well Site TU011 Location
Former Building 1608
³ 0 25 5012.5
Feet 1 inch = 35 feet
Notes Groundwater monitoring results stated in mg/L COC = Chemical of Concern J = Estimated result ISL = Initial Screening Level mg/L = Milligrams per liter TPH-D = Total Petroleum Hydrocarbon - Diesel Range Organics TPH-G = Total Petroleum Hydrocarbon - Gasoline Range Organics Parent Sample / Duplicate Sample
COC
Benzene
TPH-G
TPH-D
Oct 2018 / FD
0.0016 / 0.0024
0.39 J / 0.42
0.13 J / <0.11 J
ISL
0.005
COC
Benzene
TPH-G
TPH-D
Oct 2018 0.0081
2.6 J+
1.4
ISL
0.005
COC
Benzene
TPH-G
TPH-D
Oct 2018
0.00057 J
0.046
0.16 J
ISL
0.005
COC
Benzene
TPH-G
TPH-D
Oct 2018 <0.0004
0.01 J
0.053 J
ISL
0.005
COC
Benzene
TPH-G
TPH-D
Oct 2018 <0.0004 0.016
0.05 J
ISL
0.005
COC
Benzene
TPH-G
TPH-D
Oct 2018 <0.0004 <0.025 <0.05
ISL
0.005
@A @A
@A
@A
@A
@A
@A @A
@A
@A
@A
@A@A@A
@A@A@A
@A@A@A
@A
@A@A@A
@A@A
@A
@A
@A@A
@A
@A
@A
@A
@A
@A
@A
FPW‐1
MW‐2
MW‐5
MW‐6
MW‐7
MW‐8
MW‐9
MW‐10
MW‐11
MW‐12
ANGMW‐13A
ANGMW‐13B
ANGMW‐13C
ANGMW‐14A
ANGMW‐14B ANGMW‐14C
ANGMW‐15A
ANGMW‐15B
ANGMW‐15C
ANGMW‐17AANGMW‐17B
ANGMW‐17C
ANGMW‐18B
ANGMW‐18C
ANGMW‐19
ANGMW‐20
ANGMW‐21
ANGMW‐22
S1/2MW‐23 S1/2MW‐24
S1MW‐1
S2MW‐2
UST‐012MW
UST‐016MW
Site ST008
CLINTON AVE
N
W
2nd ST
W
3rd ST
Site SS002
SLC \\Brookside\gis_share\ENBG\00_Proj\A\AirNationalGuard\UANG\MapFiles\GWR_2017_Sep_Dec\Fig03‐03_Groundwater Monitoring Analysis Results ‐ Sept2017.mxd JN025436 4/4/2018 16:04:21
LEGEND
@A Monitoring Wells
Building Number50
FIGURE 3-4
Groundwater Monitoring Analysis Results - October 2018 151st Air Refueling Wing, Utah Air National Guard Salt Lake City, Utah
³ 0 50 10025
Feet 1 inch = 100 feet
Notes:
1. All concentrations reported in micrograms per liter (µg/L).
2. All wells sampled between October 2 - October 9.
3. 1,1-DCE = 1,1-Dichloroethene, cis-1,2-DCE = cis-1,2-Dichloroethene, trans-1,2-DCE = trans-1,2-Dichloroethene, TCE = Trichloroethene, VC = Vinyl Chloride.
4. J = The analyte was positively identified: the associated numerical value is the approximate concentration of the analyte in the sample.
5. # / # = Parent Sample Concentration / Field Duplicate Concentration.
6. Bold indicates the analyte was detected.
7. Red indicates the analyte exceeded cleanup level.
Analyte Cleanup Level (µg/L)
1,1‐DCE 7
cis‐1,2‐DCE 70 trans‐1,2‐DCE 100
TCE 5
VC 2
Analyte ANGMW‐13C
1,1‐DCE < 0.8
cis‐1,2‐DCE < 0.4 trans‐1,2‐DCE < 0.4
TCE < 0.4
VC < 0.2
Analyte ANGMW‐15A
1,1‐DCE < 0.8
cis‐1,2‐DCE 0.98 J trans‐1,2‐DCE 0.69 J
TCE 0.16 J
VC 1.2 J
Analyte ANGMW‐15B
1,1‐DCE < 0.8
cis‐1,2‐DCE 2.0 trans‐1,2‐DCE 1.0
TCE 0.3 J
VC 2.2
Analyte ANGMW‐15C
1,1‐DCE < 0.8
cis‐1,2‐DCE 0.46 J trans‐1,2‐DCE < 0.4
TCE < 0.4
VC 0.12
Analyte ANGMW‐16A
1,1‐DCE < 0.8
cis‐1,2‐DCE 1.1 trans‐1,2‐DCE < 0.4
TCE < 0.4
VC 6.9
Analyte ANGMW‐18B
1,1‐DCE < 0.8
cis‐1,2‐DCE < 0.4 trans‐1,2‐DCE < 0.4
TCE < 0.4
VC < 0.2
Analyte ANGMW‐18C
1,1‐DCE < 0.8
cis‐1,2‐DCE < 0.4 trans‐1,2‐DCE < 0.4
TCE < 0.4
VC < 0.2
Analyte ANGMW‐19
1,1‐DCE 1.3
cis‐1,2‐DCE 100 trans‐1,2‐DCE 31
TCE < 0.4
VC 210
Analyte MW‐2
1,1‐DCE < 0.8
cis‐1,2‐DCE 0.37 J trans‐1,2‐DCE < 0.4
TCE 0.73 J
VC < 0.2
Analyte MW‐4
1,1‐DCE < 0.8 /< 0.8
cis‐1,2‐DCE 1.8 / 2 trans‐1,2‐DCE 7.8 / 6.7
TCE < 0.4 / 0.18 J
VC 19 / 23
Analyte MW‐5
1,1‐DCE < 0.8
cis‐1,2‐DCE < 0.4 trans‐1,2‐DCE < 0.4
TCE 0.23 J
VC < 0.2
Analyte S1/2MW‐23
1,1‐DCE < 0.8
cis‐1,2‐DCE 2.3 trans‐1,2‐DCE 4.4
TCE < 0.4
VC 9.3
Analyte S1/2MW‐24
1,1‐DCE < 0.8
cis‐1,2‐DCE < 0.4 trans‐1,2‐DCE < 0.4
TCE 0.48 J
VC 0.17 J
Analyte S2MW‐2
1,1‐DCE 28/24
cis‐1,2‐DCE 2,900/2,800 trans‐1,2‐DCE 61/53
TCE 1,400/1,500
VC 650/590
Analyte UST‐011MW
1,1‐DCE < 0.8
cis‐1,2‐DCE 0.64 J trans‐1,2‐DCE 2.4
TCE < 0.4
VC < 0.2
Analyte UST‐016MW
1,1‐DCE < 0.8
cis‐1,2‐DCE 0.33 J trans‐1,2‐DCE < 0.4
TCE < 0.4
VC
Analyte ANGMW‐22
1,1‐DCE < 0.8
cis‐1,2‐DCE 0.66 J trans‐1,2‐DCE 50
TCE 0.21 J
VC 11
Analyte ANGMW‐20
1,1‐DCE < 0.8
cis‐1,2‐DCE < 0.4 trans‐1,2‐DCE < 0.4
TCE 0.29 J
VC < 0.2
< 0.2
| USEB132001 - 5d. Env Summary |
| USEB132001 - 5d-1. [IRP Wells] Sites 2 and 8 GW Long-Term Monitoring Report (Aug 2018) |
| USEB132001 - 5d-2. [IRP Wells] Unmarked SE Corner - temp |
| USEB132001 - 5d-3. [IRP Zones] Pages from SLC_Annual_Site2and8_GWRpt_2018_Final |
| USEB132001 - 5d-4. [IRP Zones] Pages from SLC_SiteTU011_Oct2018SemiAnnual_GWRpt_Final |
File details come from the government source that posted it. Updated .