Text version

PROJECT:

CUSTOMER:

ARCHITECT:

REPRESENTATIVE:

DATE: SHT: OF

FILENAME:

© 2019 Viking Product Group

HEAT STACK (DRAWBAND/CLAMP TERMINATION)

LSR_2Ply_MB_M_HeatStackClamp_GREENWELD.dwg 2 PLY MOD BIT

AutoCAD SHX Text

GREENWELD CAP PLY 2" MIN. LAP HEAT WELD TO PATCH PLY

AutoCAD SHX Text

GREENWELD PATCH PLY 8" MIN. ON FIELD, SET IN APPROVED ADHESIVE/SEALANT

AutoCAD SHX Text

ROOF SURFACE MATERIAL

AutoCAD SHX Text

SUBSTRATE

AutoCAD SHX Text

DRAWBAND/CLAMP

AutoCAD SHX Text

HEAT STACK

AutoCAD SHX Text

SEALANT, REFERENCE SPECIFICATION

AutoCAD SHX Text

SEAL GAP AROUND PIPES W/APPROVED ADHESIVE/SEALANT WHEN INSTALLING PATCH PLY

AutoCAD SHX Text

METAL DECK

AutoCAD SHX Text

ADHERE GREENWELD TO STACK W/APPROVED ADHESIVE/SEALANT DIMPLE SIDE DOWN

AutoCAD SHX Text

SEAL GAP AROUND STACK W/APPROVED ADHESIVE OR MASTIC

AutoCAD SHX Text NOTE: 1. APPLY APPROVED SEALANT TO ALL SEAMS/EXPOSED EDGES APPLY APPROVED SEALANT TO ALL SEAMS/EXPOSED EDGES 2. WHEN ROOF SURFACE MATERIAL IS EXPOSED BITUMEN/COLD WHEN ROOF SURFACE MATERIAL IS EXPOSED BITUMEN/COLD ADHESIVE (I,E.., FLOOD COAT), SUBSTITUTE A MODIFIED BITUMEN CAP SHEET FOR THE PATCH PLY IN LIEU GREENWELD MATERIAL 3. INSTALL GREENWELD DIMPLE SIDE DOWNINSTALL GREENWELD DIMPLE SIDE DOWN