VGLZ162323 B154 Addendum 01.pdf
PDF 4 MB Posted
- Solicitation number
- W50S8523B0004
About this file
This solicitation provides the project details for VGLZ 162323: ADAL Fuel Cell & Corrosion Control, Bldg. 154. The project includes renovating and adding onto an existing 17,650 square foot facility to enhance support areas and offices, replace finishes and fixtures, upgrade utilities, and renovate two hangar bays in phases. Proposed site improvements involve parking lot and utility modifications. The solicitation is for a firm fixed-price construction contract to be awarded by the Department of the Army Michigan Army National Guard. The work includes renovating and reconfiguring the administration and support areas of the existing building, replacing doors, windows and finishes, upgrading electrical and mechanical systems, and renovating the hangar bays in phases to allow continued operations. The exterior work involves demolishing existing structures and pavements and improving utilities, including a new water storage tank, pumping station and distribution mains to supply fire suppression to multiple buildings.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VGLZ162323 B154 Addendum 01 Page 1 of 2
Project name:
ADAL Fuel Cell/Corrosion Control
Hangar, Building 154 Client: Selfridge ANGB
Project location: Harrison Township, MI Client representative: Derek Probstfeld
Project number: VGLZ162323 Date: June 2, 2023
TO ALL BIDDERS: You are requested to make all changes and/or additions contained in this Addendum to the Bidding Documents. Failure to acknowledge this Addendum in Proposal shall result in rejection of bid.
I. DRAWINGS
A. Drawing -A-101:
1. Updated Keyed Note 4.122 to read “RELOCATED EXTERNAL JET FUEL TANK…”
B. Drawing A-102:
1. Updated Keyed Note 4.705 to read “ALL INTERIOR WALLS AND EXPOSED STRUCTURE
TO RECEIVE PAINT FINISH (PT-1), FLOOR TO BE SEALED CONCRETE (SC-1), SEE A-
601 FOR ARCHITECRUAL FINISHES SCHEDULE.”
C. Drawing A-121:
1. Add in Keyed Note “4.181 FALL PROTECITON EQUIPMENT, REFERENCE STRUCTURAL
DRAWINGS”
D. Drawing A-401:
1. Updated Toilet Accessory Key to indicate items not used. Clarified LSD on plans/details 3, 4, 5, 8, 17, 18, 20, 23, and 24.
E. Drawing A-602:
1. Updated Door and Hardware Schedule General Notes to identify which were not used.
F. Drawing F-001:
1. Removed TEXT SIGN from FIRE ALARM/MNS SYMBOLS.
G. Drawing F-102:
1. Added General Note I regarding foam removal and disposal.
H. Drawing F-103:
1. Removed Text Sign symbol from 6 locations.
I. Drawing F-602:
1. Remove column for Initiate Text Signs.
Addendum No. 1
VGLZ162323 B154 Addendum 01 Page 2 of 2
J. Drawing F-603:
1. Remove Text Signs (6 total) from Fire Alarm/MNS Riser Diagram.
2. Modified notification appliance circuits in Fire Alarm System Riser Diagram.
K. Drawing F-605:
1. Modified circuits in from Fire Alarm Riser Diagram.
II. SPECIFICATIONS
A. Table of Contents
a. Add Section 33 52 43.13 to the TOC.
B. Section 01 33 00
a. Replace existing Submittal Register with updated Submittal Register attached. Added submittal requirements for Section 33 52 43.13 to the list.
C. Section 22 00 00
a. Section 3.12 TABLES: Table II: Add “SERVICE E” column to table.
D. Section 28 31 76
a. In 1.1 References: Add in ASTM F402, UFC 3-600-01, UFC 4-211-01, ANGETL 15-01-03, UL 497A, UL 2024, and UL 2075 and their titles in the correct alphanumeric locations.
b. Delete “textual visual, “ from paragraph 1.4.3, third line.
c. Delete “Textual Display Signs; G” from SD-03 Product Data in paragraph 1.5
SUBMITTALS.
d. Delete “textual display sign “ from paragraph 1.6 SYSTEM OPERATION, first line.
e. Replace Class “A” with Class “B” in paragraph 1.6.1.a and 1.6.1.b.
f. Delete subparagraph “g. One textual visual notification appliance.” from paragraph 1.11.1.
g. Section 2.3.c: replace “Provide adequate discrete outputs to temporarily deactivate fire alarm audible notification, initiate/synchronize strobes and initiate textual visual notification appliances.” with “Provide adequate discrete outputs to temporarily deactivate fire alarm audible notification and initiate/synchronize strobes.”
h. Delete “ or LED text displays.” from end of third to last sentence of paragraph 2.3.4.a.
i. Delete “ or LED text displays.” from last sentence of paragraph 2.4.1.
j. Replace Class “A” with Class “B” in paragraph 2.9 and 2.10.
k. Delete last sentence of paragraph 2.12.2.1.d.
l. Delete last sentence of paragraph 2.14.1.1.
E. Section 33 52 43.13
a. Add attached new section to the specifications.
F. Section 33 56 10
a. Replace existing section 33 56 10 with updated version attached.
END OF ADDENDUM
F.E.F.E.
F .E
. F .E
F .E
F.E.
F .E
F.E.
FLOOR PLAN GENERAL NOTES:
1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON SITE PLAN = 100'-0" ON
ARCHITECTURAL DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE CONTRACTING OFFICER FOR FINAL DECISION.
3. ALL INTERIOR DIMENSIONS ARE FROM FINISH FACE OF WALLS (I.E. GYPSUM
WALLBOARD OR CMU), UNLESS NOTED OTHERWISE.
4. FINISH FLOOR ELEVATIONS ARE TO THE TOP OF CONCRETE, UNLESS NOTED
OTHERWISE.
5. REFERENCE SHEET G-011 AND G-021 FOR ALL CODE, FIRE RATING, AND
SEPARATION REQUIREMENTS.
6. GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING CONSTRUCTION
(WALLS, DOORS, CEILINGS, FLOORS, ETC.) AS REQUIRED FROM DEMOLITION
OR CONSTRUCTION TO ALLOW FOR THE PREP WORK AND NEW OR
COMPLETION OF EXISTING FINISHES. PROVIDE CONCRETE/PLASTER PARGE AT
ALL CMU JAMBS AND PERPENDICULAR WALL REMOVAL. REPAIRS OR
REPLACEMENTS MUST BE DURABLE, SEAMLESS, AND MATCH THE EXISTING
MATERIAL.
7. GENERAL CONTRACTOR SHALL PATCH ALL FLOOR AND WALL PENETRATIONS
CAUSED BY DEMOLITION OF MECHANICAL, ELECTRICAL, TECHNOLOGY, AND
PLUMBING, INCLUDING BUT NOT LIMITED TO PIPING AND CONDUIT RUNS, IN A
MANNER THAT IS CONSISTENT WITH THE EXISTING FLOOR AND WALL
CONSTRUCTION AND FINISH. ALL PENETRATIONS SHALL MEET REQUIRED FIRE
RATINGS.
8. COORDINATE THE INSTALLATION OF ALL OWNER-SUPPLIED EQUIPMENT.
REFERENCE PLANS, SPECS, AND INTERIOR ELEVATIONS FOR SPECIFIC
EQUIPMENT AND ITS INSTALLATION REQUIREMENTS.
9. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING, STIFFENERS, BRACINGS,
BACKING PLATES, SUPPORTING BRACKETS, AND NECESSARY SELECTIVE
DEMOLITION REQUIRED FOR THE PROPER INSTALLATION OF ALL CASEWORK,
TOILET ROOM ACCESSORIES, TOILET PARTITIONS AND MISCELLANEOUS
EQUIPMENT.
10. EXISTING AND INFILL CONCRETE SUB-FLOOR SHALL BE MADE LEVEL, PLUMB
AND IN SOUND CONDITION AS REQUIRED FOR THE INSTALLATION OF FINAL
FLOOR FINISHES, TYPICAL. PROVIDE ARDEX OR EQUAL LEVELING CONCRETE
TO PROVIDE A SMOOTH WALKABLE AREA.
11. ALL RECESSED CABINETS, PANELS, BOXES, ETC. LOCATED IN FIRE-RATED
PARTITIONS SHALL BE INSTALLED IN A MANNER WHICH MAINTAINS THE FIRE
RATED CONSTRUCTION.
12. SEE ENLARGED PLANS FOR NOTES, DIMENSIONS, AND WALL TYPES WITHIN
THE DETAIL CALLOUT BOUNDARIES.
13. REFERENCE SHEET A-002 FOR INTERIOR PARTITION TYPES. INTERIOR
PARTITION TAGS NOTED ENCOMPASS THE ENTIRE LENGTH OF WALL SHOWN
TO CORNERS OF ROOM, OVER AND AROUND DOORWAYS SHOWN.
14. REFERENCE SHEET A-800'S FOR SIGNAGE LAYOUTS AND COORDINATION
REQUIREMENTS.
15. REFERENCE SHEET A-900'S FOR FURNITURE AND EQUIPMENT LAYOUTS AND
COORDINATION REQUIREMENTS.
16. REFERENCE V-001 FOR ALL CONSTRUCTION HAUL ROUTE AND STAGING
REQUIREMENTS.
L K J H G F E D.3 D C B A
1.3
7.3
A-301
A-301
7.5
CLASSROOM/
BREAK
OFFICE
OFFICE
OPEN OFFICE
EXTERNAL
FUEL TANK
OFFICE/ TOOL
STORAGE
EXTERNAL
FUEL TANK
UTILITY
FIRE
PROTECTION
ROOM
ELECTRICAL
MAINTENANCE/
CORROSION
DOCK
MAINTENANCE/
CORROSION
DOCK
WASH ROOM
SHOWER
GEAR
LOCKER/
LAUNDRY
CORRIDOR
CORRIDOR
VESTIBULE
WOMEN'S
MEN'S
JANITOR
CORRIDOR
STORAGE
STORAGE
89'-8"
A-2014
A-201
A-201
A-201 2
A-301
A-501
SIM.
A-501
SIM.
A-301
A-401
A-401
7'-8" 3'-4" 6'-8" 14'-8" 13'-5"
A-301
W1
A
B
B
119B
119A
129A 129B
130B 130A
E104B
E104C
E104AE103A
E103C
E103B
C
VEST
SHOWER
VEST
E104DE103D
MA8
MA8
MA8
MA8
MA8
MA8
MA8
MA8
MA8
MA8
MA8
1H
MA8
1H
W2W1
W2
A-4213
/4
/2
10'-9 1/2"
17'-10 1/2"
A-501
SIM.
4.108 4.108
4.110 4.110
4.1054.105 4.105
4.105
4.104
4.122
4.133 4.133
4.134
4.134
4.136
105A
F
IE
L D
V E
R
IF
Y
24'-6" 18'-3" 7'-3" 7'-8" 33'-6" 18'-6" 18'-6" 10'-6" 1'-0" 18'-8" 18'-3" 18'-3" 24'-6"
A-301
4.1384.138
4.151
4.153
4.1544.154 4.154
4.154
MA6
2'-0" 5
+/- 14' - 4"
4.106 4.106
G F E
A-301
A-301
A-301
/8
2'-0 3/8"
4.152
4.152
4.151
4.151
MA2
2H
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
/1
/2
:2
:1
A
M C
R e v it L o c a l\
-1
.0
-A
-C e n tr a l-
P a t.
C a s e y
L L
F U
.r v t
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
W
IL
B
U R
W R
IG
H
T B
L V
D
H A
R R
IS
O
N T
W P
M
IC
H
IG
A
N
A D
A L F
U E
L C
E L L
C O
R R
O S
IO
N
C O
N T
R O
L
B L D
G
A-101
FIRST FLOOR PLAN
VGLZ162323ANG NO.:
3141700-181848.01
PJC
REK, KM
December 16, 2022
PJC
KEYED NOTES
4.104 PROVIDE OVERHEAD SECTIONAL DOOR AND FRAME - SEE SCHEDULE.
PATCH, REPAIR AND INFILL ADJACENT OPENINGS WITH MASONRY AND
EXTERIOR METAL PANEL CLADDING TO MATCH EXISTING WALL FINISH.
PROVIDE PROPER METAL PANEL J-CHANNEL OR SHEET METAL FLASHING
CLOSURE ELEMENT AT CUT LOCATIONS.
4.105 PROVIDE ALUMINUM FRAME INSULATED GLAZED WINDOWS. REFERENCE
WINDOW TYPES.
4.106 PROVIDE NEW SEALANT ALL AROUND PERIMETER, PAINT DOOR AND
FRAME.
4.108 INFILL OPENING WITH CMU WALL TO MATCH EXISTING THICKNESS AND
FINISH
4.110 HANGAR DOOR, UPGRADE ELECTRICAL TO PROVIDE EMERGENCY POWER
AND OPERATION BY THE FIRE DEPARTMENT, SEE ELECTRICAL DRAWINGS
FOR ADDITIONAL REQUIREMENTS.
4.122 RELOCATED EXTERNAL JET FUEL TANK, SEE CIVIL AND PLUMBING PLANS
FOR ADDITIONAL REQUIREMENTS.
4.133 RESURFACE FLOOR, GRIND EXISTING FLOOR, PROVIDE ESD-1
(ELECTROSTATIC DISSIPATIVE) RESINOUS EPOXY FLOOR WITH
POLYURETHANE TOP COAT.
4.134 INSTALL BOLLARDS, REFERENCE STRUCTURAL FOR DETAILS
4.135 METAL TRANSITION STRIP
4.136 INSTALL MASONRY WALL CLEAR OF EXISTING BRIDGE CRANE RAILS
4.138 (ABI #1) REPLACE FABRIC ON HANGAR DOORS - BOTH SIDES.
4.151 ROOF ACCESS LADDER
4.152 GUARD RAIL, EXTEND TO NEAREST WALL OR 6 FEET MINIMUM FROM
SURFACE EDGE
4.153 GENERATOR ACCESS PLATFORM, REFERENCE STRUCTURAL AND
ELECTRICAL DRAWINGS.
4.154 PROVIDE WINDOW BLINDS,
1/8" = 1'-0"1
FIRST FLOOR PLAN 12/16/22 TYPE B3 FINAL
HEF MOD
A 06/02/23 ADDENDUM #1
1/8" = 1'-0"2
MEZZANINE PLAN
A
FLOOR PLAN GENERAL NOTES:
1. SITE DATUM OF FINISHED FIRST FLOOR INDICATED ON SITE PLAN = 100'-0" ON
ARCHITECTURAL DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE CONTRACTING OFFICER FOR FINAL DECISION.
3. ALL INTERIOR DIMENSIONS ARE FROM FINISH FACE OF WALLS (I.E. GYPSUM
WALLBOARD OR CMU), UNLESS NOTED OTHERWISE.
4. FINISH FLOOR ELEVATIONS ARE TO THE TOP OF CONCRETE, UNLESS NOTED
OTHERWISE.
5. REFERENCE SHEET G-011 AND G-021 FOR ALL CODE, FIRE RATING, AND
SEPARATION REQUIREMENTS.
6. GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING CONSTRUCTION
(WALLS, DOORS, CEILINGS, FLOORS, ETC.) AS REQUIRED FROM DEMOLITION
OR CONSTRUCTION TO ALLOW FOR THE PREP WORK AND NEW OR
COMPLETION OF EXISTING FINISHES. REPAIRS OR REPLACEMENTS MUST BE
DURABLE, SEAMLESS, AND MATCH THE EXISTING MATERIAL.
7. GENERAL CONTRACTOR SHALL PATCH ALL FLOOR AND WALL PENETRATIONS
CAUSED BY DEMOLITION OF MECHANICAL, ELECTRICAL, TECHNOLOGY, AND
PLUMBING, INCLUDING BUT NOT LIMITED TO PIPING AND CONDUIT RUNS, IN A
MANNER THAT IS CONSISTENT WITH THE EXISTING FLOOR AND WALL
CONSTRUCTION AND FINISH. ALL PENETRATIONS SHALL MEET REQUIRED FIRE
RATINGS.
8. COORDINATE THE INSTALLATION OF ALL OWNER-SUPPLIED EQUIPMENT.
REFERENCE PLANS, SPECS, AND INTERIOR ELEVATIONS FOR SPECIFIC
EQUIPMENT AND ITS INSTALLATION REQUIREMENTS.
9. GENERAL CONTRACTOR SHALL PROVIDE BLOCKING, STIFFENERS, BRACINGS,
BACKING PLATES, SUPPORTING BRACKETS, AND NECESSARY SELECTIVE
DEMOLITION REQUIRED FOR THE PROPER INSTALLATION OF ALL CASEWORK,
TOILET ROOM ACCESSORIES, TOILET PARTITIONS AND MISCELLANEOUS
EQUIPMENT.
10. EXISTING AND INFILL CONCRETE SUB-FLOOR SHALL BE MADE LEVEL, PLUMB
AND IN SOUND CONDITION AS REQUIRED FOR THE INSTALLATION OF FINAL
FLOOR FINISHES, TYPICAL. PROVIDE ARDEX OR EQUAL LEVELING CONCRETE
TO PROVIDE A SMOOTH WALKABLE AREA.
11. ALL RECESSED CABINETS, PANELS, BOXES, ETC. LOCATED IN FIRE-RATED
PARTITIONS SHALL BE INSTALLED IN A MANNER WHICH MAINTAINS THE FIRE
RATED CONSTRUCTION.
12. SEE ENLARGED PLANS FOR NOTES, DIMENSIONS, AND WALL TYPES WITHIN
THE DETAIL CALLOUT BOUNDARIES.
13. REFERENCE SHEET A-002 FOR INTERIOR PARTITION TYPES. INTERIOR
PARTITION TAGS NOTED ENCOMPASS THE ENTIRE LENGTH OF WALL SHOWN
TO CORNERS OF ROOM, OVER AND AROUND DOORWAYS SHOWN.
4.004
4.004
4.004
4.004
4.004
4.004
4.001
4.001
4.001
4.005
A-2021 A-202 4
A-202
A-202
1'-2 1/2" 24'-11"
1'-2 1/2"
11'-4"
A-302
A-302
4.102
4.108
4.108
4.108
FIRE PUMP
ROOM
E10
TRANSFORMER SEE ELECTRICAL GENERATOR SEE ELECTRICAL
EQUIPMENT PAD
SEE STRUCTURAL
4.705
4.705
/4
13'-9"
/4
A-202 4
A-202
A-302
A-302
4.170
4.169
4.170
4.171
4.203
2'-4"
2'-4"
Roof Zone 2
ASCE-7
Roof Zone 3
ASCE-7
DEMOLITION PLAN GENERAL NOTES:
1. THE GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING AND SITE
CONDITIONS AND REPORT ANY DISCREPANCIES TO THE CONTRACTING
OFFICER BEFORE PROCEEDING WITH ANY SCHEDULED DEMOLITION WORK.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL,
STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, TECHNOLOGY, AND
PLUMBING WORK AND ALL SUBCONTRACTORS FOR DEMOLITION AND REPAIR
WORK.
3. IT IS THE INTENT OF THESE DRAWINGS TO INDICATE THE REMOVAL OF ALL
ITEMS WHICH INTERFERE WITH THE FINAL CONSTRUCTION AS SHOWN ON
THE FLOOR PLANS, ELEVATIONS, DETAILS, AND SCHEDULES. ALL FLOOR
FINISHES, BASE, CEILINGS, ABANDONED FURNITURE, WINDOW TREATMENTS,
SHELVING, SIGNAGE, AND ROOFING MATERIALS SHALL BE DEMOLISHED IN
THEIR ENTIRETY.
4. REMOVE ALL ITEMS OF DEMOLITION WORK FROM THE PROJECT DAILY AND
DISPOSE OF PROPERLY.
5. EXISTING CONCRETE AND STEEL STRUCTURE TO REMAIN, TYP. PROTECT
COLUMNS, PILASTERS, BEAMS, AND SLABS.
6. THE EXISTING MECHANICAL, ELECTRICAL,TECHNOLOGY, AND PLUMBING
ITEMS AND/OR SYSTEMS, AND GAS, WATER AND ELECTRICAL METERS ARE
GENERALLY INTENDED TO REMAIN. WHERE WORK CONFLICTS WITH NEW
WORK, DEMOLITION OR REROUTING OF EXISTING INFRASTRUCTURE SHALL
BE REQUIRED. REF: MEP FOR ALL ITEMS TO BE REUSED TYP. ALL ITEMS TO BE
DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY, BACK TO THE ORIGINAL
SOURCE. SURROUNDING MATERIALS WHICH ARE DISTURBED OR
DEMOLISHED THAT ARE SCHEDULED TO REMAIN SHALL BE PATCHED WITH
LIKE SURROUNDING MATERIALS, TYPICAL.
7. DEMOLISH CONCRETE FLOOR SLABS AS REQUIRED TO INSTALL NEW
EQUIPMENT, UNDERGROUND CONDUIT, PLUMBING SYSTEMS, AND FLOOR
DRAINS, REF: STRUCTURAL, EQUIPMENT, ELECTRICAL, PLUMBING
DEMOLITION, AND PLUMBING DRAWINGS.
8. PROTECT EXISTING SURFACES TO REMAIN DURING DEMOLITION AND
CONSTRUCTION.
9. REPAIR OR REPLACE ANY EXISTING CONSTRUCTION (WINDOWS, WALLS,
DOORS, CEILINGS, FLOORS, ETC.) TO REMAIN WHICH ARE DAMAGED DURING
CONSTRUCTION. REPLACEMENT MATERIAL SHALL MATCH IN KIND.
10. REFERENCE SHEET G-101 PHASING PLAN FOR CONSTRUCTION PHASING /
SEQUENCING AND SITE ACCESS.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
/1
/2
:3
:2
A
M C
R e v it L o c a l\
-1
.0
-A
-F P
-C e n tr a l-
P a t.
C a s e y
L L
F U
.r v t
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
W
IL
B
U R
W R
IG
H
T B
L V
D
H A
R R
IS
O
N T
W P
M
IC
H
IG
A
N
A D
A L F
U E
L C
E L L
C O
R R
O S
IO
N
C O
N T
R O
L
B L D
G
A-102
B158 FIRE PUMP
BUILDINGS PLANS
VGLZ162323ANG NO.:
3141700-181848.01
PJC
REK
December 16, 2022
PJC
KEYED NOTES
4.001 REMOVE WALL IN ITS ENTIRETY. PATCH, REPAIR AND PREP ADJACENT
SURFACES TO ACCEPT NEW CONSTRUCTION
4.004 REMOVE EXISTING DOOR, FRAME AND ASSOCIATED HARDWARE. PATCH
REPAIR AND PREP FOR NEW CONSTRUCTION
4.005 REMOVE EXISTING ALUMINUM WINDOW, FRAME AND ASSOCIATED
HARDWARE, PATCH, REPAIR AND PREP FOR NEW CONSTRUCTION
4.102 PROVIDE HM DOORS WITH HM FRAMES, AND HARDWARE - REFERENCE
SCHEDULE.
4.108 INFILL OPENING WITH CMU WALL TO MATCH EXISTING THICKNESS AND
FINISH
4.169 PATCH AND REPAIR ROOF WHERE MECHANICAL EQUIPMENT WAS
REMOVED, SEE MECHANICAL PLANS, SPLICE NEW MEMBRANE TO EXISTING
WITH MANUFACTURER'S RECOMMENDED CONNECTIONS TO MAINTAIN
ROOF WARRANTY. MATCH SLOPE WITH ADJACENT ROOF SURFACES.
4.170 PROVIDE SINGLE PLY ROOF.
4.171 PROVIDE SCUPPER BOX AND DOWNSPOUT
4.203 PREFINISHED METAL COPING TO MATCH EXISTING PROFILE
4.705 ALL INTERIOR WALLS AND EXPOSED STRUCTURE TO RECEIVE PAINT FINISH
(PT-1), FLOOR TO BE SEALED CONCRETE (SC-1), SEE A-601 FOR
ARCHITECTURAL FINISHES SCHEDULE
1/4" = 1'-0"1
DEMOLITION PLAN
1/4" = 1'-0"2
FIRST FLOOR PLAN
1/4" = 1'-0"3
ROOF PLAN
12/16/22 TYPE B3 FINAL
HEF MOD
A 06/02/23 ADDENDUM #1
L K J H G F E D.3 D C B A
1.3
7.3
A-301
A-301
7.5
A-301
A-301
ACP-1
9'-0"
ACP-1
9'-0"
ACP-1
9'-0"
ACP-1
9'-0"
ACP-2
9'-0"
ACP-2
9'-0"
ACP-1
9'-0"
ACP-1
9'-0"
ACP-1
9'-0"
GYP-1
9'-0"
GYP-1
9'-0"
ACP-2
9'-0"
ACP-1
9'-0"
ACP-1
9'-0"
ACP-1
9'-0"
ACP-2
9'-0"
EXP EXP
EXP
EXP
EXP
EXP
EXP
EXP EXP
GYP-1
9'-0"
GYP-1
9'-0"
A-301
A-501
A-501
TYP.
A-501
A-501
A-501
4.1814.181 4.1814.181
AA
4.1814.181
A A
4.1814.181
CEILING PLAN GENERAL NOTES:
1. SEE ROOM FINISH SCHEDULE FOR FLOOR, WALL AND CEILING FINISHES AND
ROOM HEIGHTS.
2. FIELD VERIFY ALL DIMENSIONS, BRING ANY DISCREPANCIES TO THE
ATTENTION OF THE CONTRACTING OFFICER FOR FINAL DECISION.
3. ALL RECESSED LIGHTS, SPRINKLERS, FIRE DETECTION EQUIPMENT,
OCCUPANCY SENSORS, ETC. SHALL BE CENTERED IN THE TILES UNLESS
NOTED OTHERWISE.
4. CENTER ALL CEILING GRIDS IN SPACE UNLESS NOTED OTHERWISE.
5. ALL METAL LINEAR DIFFUSERS SHALL BE PAINTED TO MATCH SURROUNDING
WALL OR CEILING SURFACE.
2' x 2' SUSPENDED CEILING GRID
LIGHT FIXTURE (RECESSED MOUNTED)
GYPSUM BOARD CEILING/
PORTLAND CEMENT PLASTER (PAINTED)
LIGHT FIXTURE (SURFACE MOUNTED)
SUPPLY AIR DIFFUSER
RETURN AIR DIFFUSER / EXHAUST GRILL
LIGHT FIXTURE (RECESSED CAN)
LIGHT FIXTURE (SURFACE MOUNTED)
EXHAUST FAN
LIGHT FIXTURE (SUSPENDED)
LIGHT FIXTURE (SUSPENDED)OR
CEILING PLAN LEGEND: SEE ELECTRICAL FOR
EXACT FIXTURE MODEL
LIGHT FIXTURE (RECESSED MOUNTED 4" WIDE OR LESS)
8"6"
CEILING RECEPTACLES
CEILING OCCUPANCY SENSOR
CEILING FIRE ALARM DEVICES
CEILING MASS NOTIFICATION DEVICE
CEILING SPEAKER
SPRINKLER HEADS
CEILING SECURITY STRODE
CEILING CAMERA
LIGHT FIXTURE (RECESSED MOUNTED)OR
XX-X
X'-X" ELEVATION ABOVE FINISHED FLOOR
CEILING TYPE
CEILING TYPE TAG
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
/3
/2
:0
:2
A
M C
R e v it L o c a l\
-1
.0
-A -C e n tr a l-
N a te
D e
M a s te r.
rv t
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
W
IL
B
U R
W R
IG
H
T B
L V
D
H A
R R
IS
O
N T
W P
M
IC
H
IG
A
N
A D
A L F
U E
L C
E L L
C O
R R
O S
IO
N
C O
N T R
O L
B L D
G
A-121
FIRST FLOOR
CEILING PLAN
VGLZ162323ANG NO.:
3141700-181848.01
PJC
REK.KM
December 16, 2022
PJC
1/8" = 1'-0"1
REFELECTED CEILING PLAN
KEYED NOTES
4.181 FALL PROTECTION EQUIPMENT, REFERENCE STRUCTURAL DRAWINGS
12/16/22 TYPE B3 FINAL
HEF MOD
ID-03
ID-01
ID
-0
E D.3
1.3
A-301
A-301
MA6
MA8
MA8
MA8
MA8
MA8
MA8
MA8
MA6
MA6MA6
MA6
4.126
4.1264.1264.126
4.126
WOMEN'S
MEN'S
JANITOR
CORRIDOR
A-501
SIM.
A-501
SIM.
A-501
SIM.
OPP.
A-401
A-401 11
A-40113 12
TPD
GB-1
GB-3
GB-2
CR/VSC
CR/VSC
CR/VSC
MIR
LSD
LSD
PTD
EWC
URSURS
GB-1
GB-3
GB2
SND TPD
6'-8" 1'-0" 11'-3 3/8"
A-401
A-401 910
1'-9 5/8" 11'-8 1/2" 7'-1 3/4" 5'-5 3/4"
/8
/2
/2
3'-0"
A-401
MIR
PTD
LSD
GB-1
GB-4
GB-1
GB-4
HSD
HSD
CR/VSC
CR/VSC
4.125
4.125
4.1214.121
MA6
/8
MA6
1'-0"
1'-0"
3'-4"
4.157
4.157
4.157
5'-0"
/4
G F E
A-301
A-301
MA8
1H, 194"
MA8
1H, 194"
MA8
1H, 194"
MA8
1H, 194"
MA8
194"
MA8
MA8
194"
MA8
194"
4.139
4.1264.126
4.126
4.131
4.131
129A 129B 130B 130A
VEST
SHOWER
SHOWER
WASH ROOM
GEAR
LOCKER/
LAUNDRY
CORRIDOR129
VEST
MAINTENANCE/
CORROSION
DOCK
MAINTENANCE/
CORROSION
DOCK
8 3/16"
19'-4" 19'-4"
+/- 9'-6" 10'-1 7/8" 11'-4"
2'-2 3/8"
5'-2"
/8
+/-7'-11" 23'-8" 8'-0"
A-401
20 19
A-40121 15 MIR
MIR
LSD
LSD
PTD
MA8
194"
A-301
GB-4
GB-1
CR/VSC
GB-4
GB-1
CR/VSC
RH
RH
4.125
4.1414.141
4.142
4.142
TYP
1'-6"
T Y
P
4.1574.157
CONTINUOUS WOOD
BENCH WITH 1/2"
RADIUS EDGES. SEE
PLAN FOR LENGTH
STEEL BENCH
SUPPORT SEE PLAN
FOR LOCATIONS1
1'-8"
SEE STRUCTURAL FOR
SUPPORT TYPE AND
ANCHORAGE TO FLOOR
AND BENCH
FD = FLOOR DRAIN (PITCH FLOOR TO DRAIN)
CR = CURTAIN ROD (36" OPENING)
DCS = DIAPER CHANGING STATION (NOT USED)
EWC = ELECTRIC WATER COOLER
FSS = FOLDING SHOWER SEAT
GB1 = GRAB BAR (36"w. x 54"d. x 33 A.F.F.)
GB2 = GRAB BAR (36" L. x 33" A.F.F.)
GB3 = GRAB BAR (42" L. x 33" A.F.F.)
GB4 = GRAB BAR (28" L. x 33" A.F.F.)
HSD = HAND SANITIZER DISPENSER
LSD = LIQUID SOAP DISPENSER
(OWNER FURNISHED, CONTRACTOR INSTALLED)
MS = MOP STRIP
MIR = MIRROR - FRAMELESS
PTD = PAPER TOWEL DISPENSER/DISPOSAL
RH = ROBE HOOK
SCD = SEAT COVER DISPENSER (RECESSED)(NOT USED)
SD = SOAP DISH (NOT USED)
SND = SANITARY NAPKIN DISPOSAL
TPD = (2) TOILET PAPER DISPENSERS - (2 ROLL)
WR = WASTE RECEPTACLE
VSC = VINYL SHOWER CURTAIN
TOILET ROOM
ACCESSORY GENERAL NOTES:
1. LAVATORIES IN TOILET ROOM ARE SOLID SURFACE COUNTERTOPS WITH
UNDERCOUNTER MOUNTED BOWLS, BACKSPLASH SHALL BE INTEGRAL WITH
COUNTERTOP.
2. PROVIDE BLOCKING IN WALLS FOR ALL WALL MOUNTED ACCESSORIES.
3. ALL EXPOSED SURFACES OF MILLWORK TO BE P. LAMINATE ON 3/4" PART.
BD., TYPICAL, UNLESS NOTED OTHERWISE.
4. PROVIDE WATER RESISTANT GYPSUM WALLBOARD AT ALL WET AREAS
AND/OR AREAS TO RECEIVE WALL TILE.
5. SEE "ARCHITECTURAL FINISH SCHEDULE" FOR MATERIAL INFORMATION.
6. SEE SHEET A-121 FOR "CEILING FINISH" ABBREVIATIONS.
7. SEE DETAIL 7/ A-411 FOR ALL TOILET ACCESSORY MOUNTING HEIGHTS.
TOILET ACCESSORY KEY
A
A
M A
X
"M A
X
MIN
1'-3"
(URS)
URINAL
URINAL
@ NON-ADA
ACCESSIBLE
@ ADA
ACCESSIBLE
'-1
URINAL
SCREEN
(URS)
TOILET
PARTITION
(PART)
FLOOR LINE
M A
X
LIQUID SOAP
DISPENSER
(LSD)
(GFCI)
LAVATORY
MIRROR
(MIR)
C L R
M A
X
M A
X
ELECTRIC
WATER
COOLER
HI-LO
(EWC)
M
IN
SHOWER
CURTAIN
ROD
(SCR)
ROBE
HOOK
(RH)
PAPER
TOWEL
DISP.
(PTD)
(GFCI)
SANITARY
NAPKIN
DISPOSAL
(SND)
FAUCET ON
OPPOSITE WALL
FROM MOP
STRIP
(IF APPLICABLE)
SHELF W/
MOP STRIP
(MS)
MOP BASIN
FIRE
EXTINGUISHER
CABINET
(FEC)
M
A X
FOLDING
SHOWER
SEAT
(FSS)
MAX
2'-3"
1'-4" SHOWER HEIGHT
ACCESSORIES
" 2
M A
X
T.O. HOSE MOUNTING
BRACKET
DESIGN OPTION,
STD HEAD
FLEXIBLE SHOWER
SPRAY HOSE - 60" L
SINGLE LEVEL MIXING
VALVE CONTROL
GRAB BAR (GB4)
FLOOR LINE
MAX
6"
MAX
1'-0"
T
O
GRAB BAR,
REQD (GB3)
GRAB BAR,
REQD (GB1)
GRAB
BAR,
REQD
(GB2)
(2) TOILET PAPER
HOLDER DBL
ROLL (TPH)
SANITARY NAPKIN
DISPOSAL (SND)
WALL
MOUNT
TOILET
41"
39" TO
MIN
3'-6"
1'-6" 7" 8"
MIN
3'-0"
A D
A R
E Q
M A
X
HAND
SANITIZER
DISPENSER
(HSD)
PART
MIR
LSD
CR
3'-0"
1'-0"
A-421
A-401
4.158
MIR
LSD PTD
4.158
GB2
SND
TPD GB1
GB34.158
1'-0"
4.126
4.158
RH
4.158
CR/VSC
4.158
C T
B -1
C T
-2
C T
-3
C
T -2
URS
PART
CR
4.158
CR/VSC
MIR
LSD LSD
1'-0"
5'-10"
" 4
1'-0"1'-0"
A-421
4.1264.126
1'-8" 2'-8" 1'-8"
4.158
PARTPART
1'-0" 1'-0"
4.126
4.158
URS URS
T Y
P
2'-8" 2'-7" 1'-5"
2'-7" 2'-7" 2'-8 3/4"
4.126
TYP
1'-0"
4.158
PART PART
CR/VSC
CR/VSC
RH
RH
4.207
4.158
CR/VSC CR/VSC
4.158
LSD
MIR
FIRE ALARM CONTROL PANEL
4.158
CR/VSC
LSD
MIR
PTD
4.158
4.158
MIR
LSD LSD
CR/VSC
5'-10"
A-421
EQ 3'-0" EQ
4.1584.158
GFGI WASHERGFGI DRYER
1'-6"
A-401
1'-6"
FIRE ALARM CONTROL PANEL
1'-6"
4.126
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
/1
/2
:2
:2
A
M C
R e v it L o c a l\
-1
.0
-A
-C e n tr a l-
P a t.
C a s e y
L L
F U
.r v t
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
W
IL
B
U R
W R
IG
H
T B
L V
D
H A
R R
IS
O
N T
W P
M
IC
H
IG
A
N
A D
A L F
U E
L C
E L L
C O
R R
O S
IO
N
C O
N T
R O
L
B L D
G
A-401
ENLARGED PLANS,
ELEVATIONS AND
DETAILS
VGLZ162323ANG NO.:
3141700-181848.01
PJC
REK.KM
December 16, 2022
PJC
1/4" = 1'-0"4
RESTROOMS
1/4" = 1'-0"18
CONTAMINATION CONTROL AREA
KEYED NOTES
4.121 ALIGN WALL WITH EXISTING WALL
4.125 ADA BENCH, REFERENCE SPECIFICATIONS
4.126 PROVIDE HDPE LOCKERS WITH SLOPE TOP, ON 4" BASE BY MFR.
4.131 PROVIDE EMERGENCY EYE WASH AND SHOWER, COORDINATE WITH
PLUMBING.
4.139 ROOF ACCESS LADDER
4.141 FRONT LOAD DRYERS, GOVERNMENT FURNISHED, GENERAL CONTRACTOR
TO INSTALL. (GFCI)
4.142 FRONT LOAD WASHERS, GOVERNMENT FURNISHED, GENERAL
CONTRACTOR TO INSTALL. (GFCI)
4.157 SHOWER INSERT, REFERENCE PLUMBING DRAWINGS
4.158 SEE DETAIL 22/ A-401 FOR TYP. CT PATTERNING
4.207 MECHANICAL EQUIPMENT, REFERENCE MECHANICAL DRAWINGS
1 1/2" = 1'-0"1
ADA LOCKER ROOM BENCH
1/4" = 1'-0"17
ACCESSORY MOUNTING HEIGHTS
1/4" = 1'-0"8
WOMENS NORTH
12/16/22 TYPE B3 FINAL
HEF MOD
A 06/02/23 ADDENDUM #1
1/4" = 1'-0"5
WOMENS EAST
1/4" = 1'-0"14
WOMENS WEST
1/4" = 1'-0"11
WOMENS LOCKER EAST
1/4" = 1'-0"12
WOMENS SHOWER EAST
1/4" = 1'-0"13
WOMENS SHOWER WEST
1/4" = 1'-0"22
TYPICAL TILE WALL ELEVATION
1/4" = 1'-0"2
MENS NORTH
1/4" = 1'-0"3
MENS SOUTH
1/4" = 1'-0"6
MENS EAST
1/4" = 1'-0"7
MENS WEST
1/4" = 1'-0"9
MENS SHOWER EAST
1/4" = 1'-0"10
MENS SHOWER WEST
1/4" = 1'-0"23
WASHROOM NORTH
1/4" = 1'-0"24
WASHROOM SOUTH
1/4" = 1'-0"19
WASHROOM EAST
1/4" = 1'-0"20
WASHROOM WEST
1/4" = 1'-0"15
GEAR LOCKER/ LAUNDRY EAST
1/4" = 1'-0"21
GEAR LOCKER/ LAUNDRY WEST
1/4" = 1'-0"16
GEAR LOCKER/ LAUNDRY NORTH
1/4" = 1'-0"25
GEAR LOCKER/ LAUNDRY SOUTH
A
AA
A A A
A
A
A
A
F
FLUSH DOOR
SCHED.
SEE
S E
E S
C H
E D
F2
S E
E S
C H
E D
2"
SCHED.
SEE 2"
SEALANT AND BACKER
ROD, TYP. BOTH SIDES
PRE-FINISHED METAL HEAD
FLASHING WITH HEMMED
EDGE SET IN SEALANT
2" RIGID INSULATION
AIR/MOISTURE/VAPOR BARRIER
(SHOWN DASHED) ON 12" CMU
BACKUP (8" CMU BACKUP AT
SIMILAR LOCATIONS)
WEEP VENTS AT 16" O.C., TYP.
BRICK SOLDIER COURSE TO
MATCH EXISTING
MEMBRANE FLASHING
WITH TERMINATION BAR
PAINT EXPOSED STEEL
DOOR, SEE SCHEDULE
1'-1 1/4"
7 5/8" 2" 3 5/8"
5 1/4"
SEALANT AND BACKER
ROD, TYP. BOTH SIDES
2" RIGID INSULATION
AIR/MOISTURE/VAPOR BARRIER
(SHOWN DASHED) ON 12" CMU
BACKUP (8" CMU BACKUP AT
SIMILAR LOCATIONS)
BRICK
DOOR, SEE SCHEDULE
5 1/4"
DOOR
(SEE SCHEDULE)
EXTERIOR FACE OF
WALL BEYOND
THRESHOLD SET IN
SEALANT
1/2" RIGID INSULATION
BETWEEN CONCRETE
STOOP AND
CONCRETE SLAB
2" RIGID INSULATION
WALL BEYOND
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
/1
/2
:3
:2
A
M C
R e v it L o c a l\
-1
.0
-A
-F P
-C e n tr a l-
P a t.
C a s e y
L L
F U
.r v t
M
IC
H
IG
A N
A
IR
N A
T
IO
N A
L G
U A
R D
W
IL
B
U R
W R
IG
H
T B
L V
D
H A
R R
IS
O
N T
W P
M
IC
H
IG
A
N
A D
A L F
U E
L C
E L L
C O
R R
O S
IO
N
C O
N T
R O
L
B L D
G
A-602
B158 SCHEDULES
VGLZ162323ANG NO.:
3141700-181848.01
PJC
REK
December 16, 2022
PJC
2021DOOR AND HARDWARE SCHEDULE
DOOR
NUMBER
DOOR FRAME MISCELLANEOUS
REMARKS
LEAF SIZE
TYPE MAT'L
GLAZING
TYPE FINISH TYPE MAT'L
DETAILS
FINISH LABEL
HDWR
SET LINTELQTY. WIDTH HEIGHT HEAD JAMB OTHER
102 (1) 3'-0" 7'-0" F HM - PT F HM 3/A-602 2/A-602 PT -
E101 (2) 3'-0" 8'-4" N EX - PT EX EX - - - PT -
DOOR AND HARDWARE SCHEDULE ABBREVIATIONS
EX = EXISTING
FG = FIRE GLASS
IN = INSULATED
L = LEXAN MARGARD
P = 1/4" PLATE
S = SAFETY
T = TEMPERED
DOOR AND HARDWARE SCHEDULE ABBREVIATIONS
DOOR/FRAME MATERIALS
AL = ALUMINUM
EX = EXISTING
FR = FABRIC ROLL-UP
FRP = FIBERGLASS REINFORCED PLASTIC
G = GALVANIZED
HM = HOLLOW METAL
PL = PLASTIC ROLL-UP
R = RUBBER ROLL-UP
SS = STAINLESS STEEL
ST = STEEL
WD = WOOD
GLAZING TYPES
DOOR AND HARDWARE SCHEDULE GENERAL NOTES
1. PROVIDE STAINLESS STEEL GUARD CHAIN WITH CAUTION SIGN ACROSS INTERIOR SIDE OF DOOR. (NOT USED)
2. LINTEL L1 SHALL BE (2) #5 BARS, 1 COURSE HIGH.(NOT USED - SEE STRUCUTRAL FOR LINTEL SCHEDULE)
3. OPERABLE LEAF SHALL BE DOOR TYPE B AND FIXED LEAF SHAL BE DOOR TYPE A.(NOT USED)
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
1 1/2" = 1'-0"3
EXTERIOR DOOR HEAD AT BRICK
1 1/2" = 1'-0"2
EXTERIOR DOOR JAMB AT BRICK
1 1/2" = 1'-0"1
EXTERIOR DOOR SILL
12/16/22 TYPE B3 FINAL
HEF MOD
HYDRAULIC REFERENCE NODE
OS&Y VALVE WITH TAMPER
SWITCH
ISOLATION VALVE
CHECK VALVE
WATERFLOW SWITCH
PRESSURE REDUCING VALVE
POST INDICATOR VALVE
WET PIPE SYSTEM
PIPE ELEVATION AFF
FIRE DEPARTMENT
CONNECTION
PIPE CONTINUATION
DIRECTION OF FLOW
SP
[ X'-X"]
FIRE PROTECTION SYMBOLS FIRE ALARM/ MNS SYMBOLS FIRE PROTECTION GENERAL NOTES FIRE ALARM/MNS GENERAL NOTES FIRE PROTECTION ABBREVIATIONS
RSFACU
s
F
C
M
RA
FIRE ALARM/ MASS NOTIFICATION CONTROL
PANEL
REMOTE ANNUNCIATOR PANEL
FIRE ALARM/ MNS STROBE - WALL MOUNT
-XX DENOTES CANDELA RATING
FIRE ALARM/ MNS STROBE - CEILING MOUNT
-XX DENOTES CANDELA RATING
-WP DENOTES WEATHERPROOF
SPEAKER - WALL MOUNT
-WP DENOTES WEATHERPROOF
HORN - WALL MOUNT
FIRE ALARM/COMBINATION SPEAKER
/STROBE - CEILING MOUNT
-XX DENOTES CANDELA RATING
FIRE ALARM/ MNS SPEAKER - CEILING MOUNT
-WP DENOTES WEATHERPROOF
SMOKE DETECTOR - PHOTOELECTRIC
CARBON MONOXIDE DETECTOR
DUCT SMOKE DETECTOR
FIRE ALARM MANUAL PULL STATION
ADDRESSABLE INITIATING DEVICE MODULE
ADDRESSABLE CONTROL (RELAY) MODULE
PRESSURE SWITCH
WATERFLOW SWITCH
TAMPER SWITCH
EXTERIOR FIRE ALARM BELL
TRANSIENT VOLTAGE SURGE SUPPRESSOR
REMOTE TEST STATION
LOCAL OPERATING CONSOLE
RADIO TRANSMITTER
ANTENNA
REMOTE POWER SUPPLY
TEMPERATURE SENSOR
KNOX BOX
DET-TRONICS X3301 MULTISPECTRUM IR
OPTICAL FLAME DETECTOR
RELEASING SERVICE FIRE ALARM CONTROL
UNIT
TVSS
RTS
FMCP
D
LOC
XX
C
C
RT
RPS
T
K
CO
1. FIRE PROTECTION SYSTEMS SHALL COMPLY WITH PROJECT
SPECIFICATIONS, UFC 3-600-01, UFC 4-211-01, ETL 15-01-03, NFPA 13,
NFPA 20, NFPA 24, AND ALL APPLICABLE CODES AND STANDARDS.
2. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE A GENERAL
ARRANGEMENT OF WORK. GENERAL DESIGN CONCEPTS INDICATED
MUST BE FOLLOWED OR BETTERED. THE BID SHALL INCLUDE
OFFSETS, ADDITIONAL PIPING, VALVES, AND FIRE PROTECTION
EQUIPMENT AS REQUIRED TO MEET CONSTRUCTION CONDITIONS
FOR PROPER OPERATION. DEVELOP AND SUBMIT COORDINATION
DRAWINGS.
3. PIPING WILL NOT BE SHOWN FOR THE SPRINKLER SYSTEM. THE
CONTRACTOR SHALL PROVIDE FINAL ROUTING FOR ALL PIPING AND
SHALL PROVIDE SHOP DRAWINGS THAT INCLUDE: EXACT
DIMENSIONED ROUTING OF ALL PIPE, PIPE SIZES, DIMENSIONED TIE-
IN LOCATIONS AT EXISTING PIPING, AND FIRE RATED
CONSTRUCTION PENETRATIONS DETAILS. THE CONTRACTOR SHALL
AVOID INTERFERENCES WITH OTHER PIPING, EQUIPMENT, CODE
REQUIRED CLEARANCES, AND THE WORK OF OTHER DISCIPLINES.
FIELD ROUTED LIQUID-FILLED PIPING SHALL NOT BE ROUTED ABOVE
ELECTRICAL OR ELECTRONIC EQUIPMENT.
4. INSTALLING CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS
AND LICENSES.
5. DESIGN AND INSTALLATION SUBJECT TO FINAL INSPECTION AND
APPROVAL BY CONTRACTING OFFICER.
6. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS
SHALL BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
7. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, RATED
WALLS, CEILINGS, FLOOR, ROOFS, ETC. FLASH AND COUNTERFLASH
ANY ROOF PENETRATIONS.
8. METHOD OF HANGING PIPES, HEADERS, AND BRANCHLINES SHALL
BE IN ACCORDANCE WITH NFPA 13.
9. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE
UNDERWRITER'S LABORATORIES, INC. AND/OR THE FACTORY
MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED "UL"
AND/OR "FM" OR EQUIVALENT.
10. ALL NORMALLY OPEN VALVES ON THE FIRE PROTECTION SYSTEM
SHALL BE ELECTRICALLY SUPERVISED AND SHALL BE THE
RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR.
11. PROVIDE A PERMANENTLY ATTACHED HYDRAULIC NAME PLATE
STATING THE REQUIRED DESIGN CRITERIA FOR EACH
HYDRAULICALLY DESIGNED SYSTEM IN ACCORDANCE WITH NFPA 13.
12. ONLY NEW MATERIALS SHALL BE USED IN THE INSTALLATION OF
THESE SYSTEMS.
13. ALL SUPPORTS SHALL BE ATTACHED TO THE BUILDING'S
STRUCTURAL FRAME IN ACCORDANCE WITH NFPA 13.
14. INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS.
15. ROD STIFFERNER REQUIRED FOR ALL-THREAD ROD HANGERS OVER
6' IN LENGTH.
16. INSTALL UNIONS IN PIPES 2" AND SMALLER, ADJACENT TO EACH
VALVE. UNIONS ARE NOT REQUIRED ON FLANGED DEVICES OR IN
PIPING INSTALLATIONS USING GROOVED MECHANICAL COUPLINGS.
17. SAFEGUARDING DURING CONSTRUCTION SHALL BE IN ACCORDANCE
WITH ARMY CORPS OF ENGINEERING MANUAL (EM), EM-385-1-1,
SAFETY AND HEALTH REQUIREMENTS MANUAL AND NFPA 241.
CONTRACTOR SHALL COORDINATE SPECIFIC PLAN FOR FIRE
PROTECTION DURING CONSTRUCTION WITH THE CONTRACTING
OFFICER.
18. SPRINKLERS INSTALLED IN HIGH HEAT AREAS, INCLUDING BUT NOT
LIMITED TO, ATTIC SPACES, OR IN CLOSE PROXIMITY TO UNIT
HEATERS, SHALL HAVE A TEMPERATURE CLASSIFICATION IN
ACCORDANCE WITH NFPA 13.
19. EQUIPMENT SHALL BE INSTALLED WITH A MINIMUM CLEARANCE OF
36" ACCESS TO AND IN FRONT OF ALL EQUIPMENT AND 6" BEHIND
THE EQUIPMENT.
20. PROVIDE SPRINKLER PROTECTION IN COMBUSTIBLE CONCEALED
LOCATIONS IN ACCORDANCE WITH NFPA 13.
21. ALL SPRINKLER PIPING SHALL BE SCHEDULE 40 BLACK STEEL.
22. SEE SHEAR WALLS PLANS IN STRUCTURAL DRAWINGS FOR SHEAR
WALL LOCATIONS AND RESTRICTIONS ON PENETRATIONS.
1. FIRE ALARM/MASS NOTIFICATION SYSTEMS SHALL COMPLY
WITH UFC 3-600-01, UFC 4-021-01, UFC 4-211-01, ETL 15-01-03,
NFPA 70, NFPA 72, AND PROJECT SPECIFICATIONS. NOTE THAT
THE FIRE PUMP HOUSE WILL NOT BE PROVIDED WITH MASS
NOTIFICATION.
2. PENETRATIONS IN FIRE RATED ASSEMBLIES SHALL BE FIRE-
STOPPED WITH LISTED MATERIALS/ ASSEMBLIES IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
3. FIRE SUPPRESSION SYSTEM WATERFLOW AND CONTROL VALVE
SUPERVISORY SWITCHES SHALL BE MONITORED BY THE
BUILDING FIRE ALARM/ MASS NOTIFICATION SYSTEM.
4. THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF SYSTEM REQUIREMENTS WITH ALL
CONDITIONS OF THE BUILDING AND SITE INCLUDING, BUT NOT
LIMITED TO, BLIND SPACES, SHELVING, LIGHTS, HVAC GRILLES
AND DIFFUSERS, PIPING, DUCT WORK, DOORS, WINDOWS,
EQUIPMENT PLATFORMS, WALLS (FIRE RATED AND NON FIRE
RATED), BEAMS, JOISTS, COLUMNS, HVAC EQUIPMENT,
ELECTRICAL PANELS AND EQUIPMENT, CEILINGS, AREAS
WITHOUT CEILINGS, WALL CONSTRUCTION, FLOORS AND ALL
CONSTRUCTION, EQUIPMENT AND BUILDING APPURTENANCES.
5. THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR
PERFORMING, DOCUMENTING, AND CERTIFYING REQUISITE
INSPECTION AND TESTS IN ACCORDANCE WITH APPLICABLE
CODES AND STANDARDS FOR ALL FIRE ALARM EQUIPMENT
FURNISHED UNDER THIS PROJECT. AFTER COMPLETING THE
TESTING, THE CONTRACTOR SHALL DEMONSTRATE FULL
OPERATIONAL CAPABILITY OF THE FIRE ALARM/ MASS
NOTIFICATION SYSTEM, AS WELL AS FULL COMPLIANCE WITH
ALL DESIGN DOCUMENTS, CODES AND STANDARDS.
6. CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS MATERIAL
FOR A COMPLETE INSTALLATION.
7. EACH CONVENTIONAL FIRE ALARM DEVICE MUST HAVE ITS OWN
MONITOR MODULE.
8. ALL CONDUCTORS SHALL BE INSTALLED IN METALLIC
CONDUITS.
9. ALL FIRE ALARM MODULES LOCATED WITHIN 15' OF A
SPRINKLER/STANDPIPE SYSTEM RISER SHALL BE
WEATHERPROOF WITH LIQUID TIGHT CONDUIT.
10. ALL CONDUIT FROM ANY FIRE ALARM DEVICE CONNECTED TO A
DEVICE THAT MAY BE IN CONTACT WITH WATER SHALL BE
LIQUID TIGHT. THIS INCLUDES, BUT IS NOT LIMITED TO,
WATERFLOW SWITCHES, PRESSURE SWITCHES & TAMPER
SWITCHES.
11. TELECOMMUNICATIONS CONDUIT SHALL BE INSTALLED IN
ACCORDANCE WITH DIVISION 27 OF THE PROJECT
SPECIFICATIONS.
12. PROVIDE A LABEL ON THE EXTERIOR OF EACH FIRE ALARM
DEVICE THAT MATCHES THE DEVICE NUMBER (ADDRESS) AT
THE FMCP. DEVICE ID NUMBERS SHALL BE VISIBLE FROM THE
FLOOR TO THE MAXIMUM EXTENT PRACTICAL. MONITOR
MODULES & CONTROL/RELAY MODULES SHALL ALSO BE
LABELED AS TO WHAT THEY CONTROL.
13. ALL WIRING, CONDUIT, AND DEVICES LOCATED IN HAZARDOUS
ATMOSPHERES, AS DEFINED BY NFPA 70, SHALL BE EXPLOSION
PROOF. REFER TO THE ELECTRICAL PLANS FOR LOCATIONS.
ABOVE FINISHED FLOOR
AUTOMATIC TRANSFER SWITCH
CANDELA
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CHECK VALVE
CHEMICAL
CEMENT LINED DUCTILE IRON PIPE
CONTROL PANEL
DECIBEL
FIRE ALARM
FIRE ALARM BELL
FIRE ALARM CONTROL PANEL
FIRE DEPARTMENT CONNECTION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FACTORY MUTUAL
FIBER OPTIC
FIBER OPTIC TRANSCEIVER MODULE
FIRE PUMP CONTROLLER
FLOW SWITCH
FIRE SEPARATION DISTANCE
GOVERNMENT FURNISHED GOVERNMENT INSTALLED
IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODE
MANUFACTURER
MASS NOTIFICATION SYSTEM
NOTIFICATION APPLIANCE CIRCUIT
NORMALLY CLOSED
NATIONAL FIRE PROTECTION ASSOCIATION
OUTSIDE STEM AND YOKE
PUMP
POST INDICATOR VALVE
PRESSURE REDUCING VALVE
RISER CHECK VALVE
RELEASING SERVICE FIRE ALARM CONTROL UNIT
SOUNDER BASE
SCHEDULE
PHOTOELECTRIC SMOKE DETECTOR
SIGNALING LINE CIRCUIT
TANK
TO BE DETERMINED
TAMPER SWITCH
TRANSIENT VOLTAGE SURGE SUPPRESSOR
UNIFIED FACILITIES CRITERIA
UNDERWRITER'S LABORATORIES
UNLESS OTHERWISE NOTED
UNITED STATES AIR FORCE
VALVE
VARIABLE FREQUENCY DRIVE
WEATHERPROOF
ZONE CONTROL ASSEMBLY
AFF
ATS
CD
CFCI
CHKV
CHEM
CLDIP
CP
DB
FA
FAB
FACP
FDC
FE
FEC
FM
FO
FOTM
FPC
FS
FSD
GFGI
IAW
IBC
MFG
MNS
NAC
NC
NFPA
OS&Y
P
PIV
PRV
RCV
RSFAC
SB
SCH
SD
SLC
T
TBD
TS
TVSS
UFC
UL
UON
USAF
V
VFD
WP
ZCA
H
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
6/ 2/
:1
5:
P M
C :\U se rs
\B
EN
.S H
AF
FE
R \D oc um en ts
\3
-1
8.
-F
-C en tra l-2
0_
BE
N
.S H
AF
FE
R .rv t
M
IC
H
IG
AN
A
IR
N
AT
IO
N
AL
G U
AR
D
W
IL
BU
R W
R
IG
H T
BL
VD
H
AR
R
IS
O
N T
W P, M
IC
H
IG
AN
AD
AL
F U
EL
C
EL
L
C
O R
R O
SI
O
N C
O N
TR
O
L -B
LD
G
F-001
FIRE PROTECTION
LEGEND AND
SYMBOLS
VGLZ162323ANG NO.:
3141700-184848.01
RAB
RDV
December 16, 2022
RAB
12/16/22 TYPE B3 FINAL
HEF MOD
MAINTENANCE/
CORROSION
DOCK
MAINTENANCE/
CORROSION
DOCK
CLASSROOM/
BREAK
OPEN OFFICE
OFFICE
CORRIDOR
CORRIDOR
JANITOR
MEN'S
WOMEN'S
OFFICE
CORRIDOR
EXTERNAL FUEL
TANK OFFICE/
TOOL STORAGE
ELECTRICAL
FIRE
PROTECTION
ROOM
UTILITY
EXTERNAL FUEL
TANK
VESTIBULE
STORAGE
STORAGE
F-301
F-301
L K J H G F E D.3
D C B
A
1.3
7.3
7.5
F-401
WASH ROOM
123 SHOWER
GEAR LOCKER/
LAUNDRY
SHOWER
VEST
129 VEST
4" ø
(S P-
3)
4"ø (SP-3)
4"ø (FDC)
4" ø
(S P-
3)
4" ø
(S P-
2)
4"ø (SP-1)
4"ø (SP-2)
4"ø (SP-1)
4" ø
(S P-
3) 4" ø (S
P- 3)
4" ø
(S P-
1)
4" ø
(S P-
1)
4" ø
(S P-
2)
4" ø
(S P-
2)
142136
134128
79 80
69 70
45 4644
4"ø (SP-2)
2"ø (SP-2)
2"ø (SP-2)
2"ø (SP-2)
2"ø (SP-2)
2"ø (SP-2)
5.103
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
6/ 2/
:1
6:
P M
C :\U se rs
\B
EN
.S H
AF
FE
R \D oc um en ts
\3
-1
8.
-F
-C en tra l-2
0_
BE
N
.S H
AF
FE
R .rv t
M
IC
H
IG
AN
A
IR
N
AT
IO
N
AL
G U
AR
D
W
IL
BU
R W
R
IG
H T
BL
VD
H
AR
R
IS
O
N T
W P, M
IC
H
IG
AN
AD
AL
F U
EL
C
EL
L
C
O R
R O
SI
O
N C
O N
TR
O
L -B
LD
G
F-102
FIRE PROTECTION
PLAN
VGLZ162323ANG NO.:
3141700-184848.01
RAB
RDV
December 16, 2022
RAB
A. FOR FIRE PROTECTION GENERAL NOTES, LEGEND, &
ABBREVIATIONS, SEE SHEET F-001.
B. THE BUILDING SHALL BE PROVIDED WITH AN
AUTOMATIC SPRINKLER SYSTEM THROUGHOUT IN
ACCORDANCE WITH NFPA 13, UFC 3-600-01, & UFC
4-211-01.
C. DESIGN THE SPRINKLER PIPING SUCH THAT THE
MAJORITY OR ALL OF THE SYSTEM DRAINS BACK TO
THE RISER. MINIMIZE OR ELIMINATE THE
REQUIREMENT FOR REMOTE DRAINAGE
CONNECTIONS IN THE HANGAR BAY.
D. EQUIPMENT IN THE HANGAR BAY AND ROOMS WITH
DOORS TO THE HANGAR BAY SHALL BE RATED FOR
CLASS I DIV II OR LOCATED 18" ABOVE FINISHED
FLOOR.
E. DEMOLISH ALL EXISTING FIRE PROTECTION
EQUIPMENT.
F. PROVIDE SPRINLKER PROTECTION BENEATH
OBSTRUCTIONS GREATER THAN 4FT INCLUDING
DUCTWORK AND PIPING GROUPINGS.
G. INSTALL AUTOMATIC AIR VENT(S) AT AN ACCESSIBLE
HIGH POINT OF EACH SPRINKLER SYSTEM IN A LEVEL
POSITION WHERE PRESSURE GAUGE CAN BE VIEWED
FROM BELOW.
H. PARTIAL SPRINKLER SYSTEM LAYOUT IS PROVIDED
ONLY TO VERIFY HYDRAULIC DEMAND. CONTRACTOR
IS RESPONSIBLE FOR COMPLETE SYSTEM DESIGN
THROUGHOUT BUILDING.
I. DEMOLISH ALL EXISTING FOAM EQUIPMENT. PERFORM
LABORATORY ANALYTICAL TESTING OF FOAM
CONCENTRATE TO DETERMINE POTENTIAL PFOS/PFOA
CONSTITUENTS PRESENT FOR PROPER DISPOSAL
REQUIREMENTS, AS NEEDED, IAW WITH DOD
GUIDELINES. RINSE SYSTEM PIPING AND EQUIPMENT
TO REMOVE ANY FOAM CONCENTRATE (IF POTENTIAL
PFOS/PFOA CONSTITUENTS PRESENT) PRIOR TO
SYSTEM DISPOSAL. UTILIZE A CREDITED COMPANY
FOR TRANSPORT AND DISPOSAL OF THE FOAM.
GENERAL NOTES
KEYED NOTES
1/8" = 1'-0"1 FIRE PROTECTION PLAN
5.103 PROVIDE BRANCHLINE AT ROOF PEAK TO CONNECT
BRANCHES TO REDUCE THE NUMBER OF AIR VENTS
REQUIRED IN THE SYSTEM (TYPICAL FOR BOTH
HANGAR BAYS).
12/16/22 TYPE B3 FINAL
HEF MOD
F
FF
F
F
FF
F
F
F
15 15
CO
D
D D
D
D
D
MAINTENANCE/
CORROSION
DOCK
MAINTENANCE/
CORROSION
DOCK
CLASSROOM/
BREAK
OPEN OFFICE
OFFICE
CORRIDOR
JANITOR
MEN'S
OFFICE
CORRIDOR
EXTERNAL FUEL
TANK OFFICE/
TOOL STORAGE
ELECTRICAL
FIRE
PROTECTION
ROOM
UTILITY
EXTERNAL FUEL
TANK
VESTIBULE
STORAGE
STORAGE
WP
WP WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
177177177
F-301
F-301
L K J H G F E D.3
D C B
A
1.3
7.3
7.5
177 177
FM
C
P
M
K
R
PS
R T
M
RA
WASH ROOM
GEAR LOCKER/
LAUNDRY
VEST
VEST
SHOWER
124SHOWER
WP
C C
M M
WOMEN'S
C RTS
CR
TS
R
TS
C
LCOATE DUCT SMOKE DETECTOR
ON THE SUPPLY SIDE OF MAU-1
LCOATE DUCT SMOKE DETECTOR
ON THE SUPPLY SIDE OF RTU-1
CO RTS
R
TS
R
TS
CO
CO
15 WP
WP15
W
P
5.117
5.119
5.120
5.125
5.126
5.127
5.130 5.109
5.110
5.1175.1175.117
5.119
M MM M
T
5.114
M M M M
RSFACU RPS
T
T
5.160
5.159
5.161
5.161
A
AA
A
A A
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
6/ 2/
:1
6:
P M
C :\U se rs
\B
EN
.S H
AF
FE
R \D oc um en ts
\3
-1
8.
-F
-C en tra l-2
0_
BE
N
.S H
AF
FE
R .rv t
M
IC
H
IG
AN
A
IR
N
AT
IO
N
AL
G U
AR
D
W
IL
BU
R W
R
IG
H T
BL
VD
H
AR
R
IS
O
N T
W P, M
IC
H
IG
AN
AD
AL
F U
EL
C
EL
L
C
O R
R O
SI
O
N C
O N
TR
O
L -B
LD
G
F-103
FIRE ALARM/ MNS
PLAN
VGLZ162323ANG NO.:
3141700-184848.01
RAB
RDV
December 16, 2022
RAB
1/8" = 1'-0"1 FIRE ALARM/ MNS PLAN
A. FOR FIRE PROTECTION GENERAL NOTES, LEGEND, &
ABBREVIATIONS, SEE SHEET F-001.
B. DEMOLISH ALL EXISTING FIRE ALARM EQUIPMENT, WIRING,
PATHWAYS, AND ASSOCIATED EQUIPMENT.
C. MAINTAIN EXISTING FIRE ALARM EQUIPMENT FULLY
OPERATIONAL UNTIL THE NEW EQUIPMENT HAS BEEN
TESTED AND ACCEPTED BY THE CONTRACTING OFFICER.
D. LOCATE CONTROL MODULES WITHIN 36" OF CONTROL
EQUIPMENT IN ACCORDANCE WITH NFPA 72.
E. DO NOT LOCATE MONITOR AND CONTROL MODULES IN
HANGAR BAY.
F. REFER TO MECHANICAL PLANS FOR EXACT LOCATION OF
DUCT SMOKE DETECTORS AND HVAC RETURN AIR UNITS
OVER 2000 CFM.
G. EQUIPMENT INCLUDING FIRE ALARM DEVICES IN THE
HANGAR BAY AND ROOMS WITH DOORS TO THE HANGAR
BAY SHALL BE RATED FOR CLASS I DIV II UNLESS LOCATED
MORE THAN 18" ABOVE FINISHED FLOOR.
H. THE HANGAR BAY SHALL BE EQUIPPED WITH NEMA 250
TYPE 4 WALL-MOUNTED DEVICES. CONDUIT AND
JUNCTION BOXES SHALL BE WATERTIGHT.
I. PROVIDE FIRE ALARM MASS NOTIFICATION CONTROL
PANEL COMPATIBLE WITH BASE WIDE SIMPLEX SYSTEM.
J. CONTRACTOR IS RESPONSIBLE FOR OBTAINING FINAL
FLAME DETECTOR LAYOUT FROM DET-TRONICS.
GENERAL NOTES KEYED NOTES
5.109 INSTALL FIRE ALARM BELL ABOVE FDC.
5.110 WET-PIPE RISER TAMPER AND FLOW SWITCH.
5.114 SPRINKLER RISER ROOM TEMPERATURE
MONITORING.
5.117 DIRECTIONAL LOUDSPEAKERS WITH A MINIMUM
SOUNDPOWER OF 90 dBA DIRECTED TOWARDS
HANGAR BAY DOOR ONLY.
5.119 PROVIDE DISABLE SWITCH FOR FIRE ALARM
NOTIFICATION APPLIANCE TO PREVENT MICROPHONE
FEEDBACK DURING TESTING.
5.120 MAIN SYSTEM OS&Y ISOLATION VALVE.
5.125 PROVIDE KNOX BOX WITH TAMPER SWITCH
CONNECTED TO THE FIRE ALARM SYSTEM.
5.126 SHUT DOWN HVLS FANS UPON BUILDING ALARM.
5.127 AUTOMATIC GAS SHUT OFF.
5.130 RATE ALL FIRE ALARM DEVICES AND CONDUIT
LOCATED IN EXTERNAL FUEL TANK 119 AND
EXTERNAL FUEL TANK OFFICE/ TOOL STORAGE 115
FOR CLASS I DIV II IN ACCORDANCE WITH NFPA 70.
5.159 RELEASING SERVICE FIRE ALARM CONTROL UNIT.
5.160 RSFACU MONITORING MODULES.
5.161 HANGAR BAY TEMPERATURE MONITORING.
12/16/22 TYPE B3 FINAL
HEF MOD
ALARM SIGNALS
MANUAL FIRE ALARM PULL STATION
SMOKE DETECTOR
WATERFLOW SWITCH
RSFACU ALARM SIGNAL
SUPERVISORY SIGNALS
AU
D
IO
-V
IS
U
AL
F
IR
E
AL
AR
M
IN
D
IC
AT
IO
N
AU
D
IO
-V
IS
U
AL
C
O M
M O
N S
U
PE
R
VI
SO
R
Y
IN
D
IC
AT
AU
IO
-V
IS
U
AL
C
O M
M O
N T
R O
U
BL
E
IN
D
IC
AT
IO
N
FI
R
E
AL
AR
M
S
IG
N
AL
B Y
D
EV
IC
E
TY
PE
C O
M M
O N
F
IR
E
AL
AR
M
S U
PE
R
VI
SO
R Y
SI
G
N
AL
C O
M M
O N
F
IR
E
AL
AR
M
T R
O U
BL
E
SI
G
N
AL
COMMON SUPERVISORY SIGNAL BY DEVICE
DUCT SMOKE/CARBON MONOXIDE
DETECTOR
RSFACU COMMON SUPERVISORY SIGNAL
ANNUNCIATION AT FMCP TRANSMIT SIGNALS TO
RECEIVING STATION
SH
U
T D
O W
N A
SS
O
C
IA
TE
D
F
AN
(S
AUXILIARY FUNCTIONS NOTIFICATION/
EVACUATION SIGNALS
AC
TI
VA
TE
E
XT
ER
IO
R W
AT
ER
FL
O
W
AL
AR
M B
EL
L
IN
IT
IA
TE
G
EN
ER
AL
F
IR
E
AL
AR
M
/M N
S
AU
D
IB
LE
/V
IS
IB
LE
N
O
TI
FI
C
AT
IO
N A
PP
LI
AN
C
ES
OPTICAL FLAME DETECTION INHIBITED
SUPERVISORY FROM RSFACU
SH
U
T D
O W
N H
VL
S
FA
N
S
IN
H
AN
G
AR
B
AY
KNOX BOX
AU
D
IO
-V
IS
U
AL
S
U
PE
R
VI
SO
R
Y
IN
D
IC
AT
FO
R
F A
O
VE
R R
ID
E
BY
M
N S
SU
PE
R
VI
SO
R
Y
SI
G N
AL
F
O R
F A
O
VE
R R
ID
E
BY
M
N S
SH
U
T O
FF
G
AS
IN
H
AN
G
AR
TE
M
PO
R
AR
IL
Y O
VE
R
R
ID
E
TH
E
FI
R E
AL
AR
M A
U D
IB
LE
M
ES
SA
G
E
C
AR
BO
N
M O
N O
XI
D
E D
ET
EC
ET
AC
TI
VA
TI
O N
CARBON MONOXIDE DETECTOR
C
AR
BO
N
M O
N O
XI
D
E
AL
AR
M
S
IG
N
AL
IN
IT
IA
TE
F
IR
E C
AR
BO
N M
O N
O
XI
D E
PR
E-
R
EC
O R
D
ED
M
ES
SA
G
E
AN
D S
TR
O
BE
S
IN
IT
IA
TE
F
IR
E
AL
AR
M
S
PE
AK
ER
S O
N
LY
C
LO
SE
A
SS
O
C
IA
TE
D
F
IR
E/
SM
KE
AM
PE
R
TR
AN
SM
IT
A
LA
R M
S
IG
N
AL
T O
B M
S
AC
TI
VA
TE
H
AN
G
AR
B
AY
F
IR
E
AL
AR
M
M
ES
SA
G E
AC
TI
VA
TE
A C
TI
VE
S H
O O
TE
R
M
ES
SA
G
E
TEMPERATURE MONITOR
FUEL CONTAINMENT TANK 5% OF
VOLUME EXCEEDED
A
TROUBLE SIGNALS
SIGNALING LINE CIRCUIT OPEN
SIGNALING LINE CIRCUIT SHORT
SIGNALING LINE CIRCUIT GROUND
FACP CIRCUIT FAULT
FACP SUPERVISED COMPONENT FAILURE
FACP AC POWER FAILURE
FACP LOW BATTERY VOLTAGE
NOTIFICATION APPLIANCE CIRCUIT SHORT
MNS MESSAGE VIA TELEPHONE
MNS PRE-RECORDED MESSAGE
CONCURRENT FA AND MNS ALARM
GENERAL PAGING
ACTIVE SHOOTER BUTTON ON FMCP OR LOC
MASS NOTIFICATION SYSTEM (MNS) SIGNALS
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
6/ 2/
:1
6:
P M
C :\U se rs
\B
EN
.S H
AF
FE
R \D oc um en ts
\3
-1
8.
-F
-C en tra l-2
0_
BE
N
.S H
AF
FE
R .rv t
M
IC
H
IG
AN
A
IR
N
AT
IO
N
AL
G U
AR
D
W
IL
BU
R W
R
IG
H T
BL
VD
H
AR
R
IS
O
N T
W P, M
IC
H
IG
AN
AD
AL
F U
EL
C
EL
L
C
O R
R O
SI
O
N C
O N
TR
O
L -B
LD
G
F-602
FIRE ALARM
FUNCTIONAL MATRIX
VGLZ162323ANG NO.:
3141700-184848.01
RAB
RDV
December 16, 2022
RAB
NTS1 FIRE ALARM FUNCTIONAL MATRIX
FIRE ALARM/MNS GENERAL NOTES
A. FOR FIRE PROTECTION GENERAL NOTES, LEGEND, &
ABBREVIATIONS, SEE SHEET F-001.
12/16/22 TYPE B3 FINAL
FIRE ALARM / MASS
NOTIFICATION SYSTEM
CONTROL PANEL (FMCP)
BATTERIES
G
EN
EE
R L
AL
AR
M S
IG
N
AL
M M M
RSFACU
M
SIGNALING
LINE CIRCUIT
DEDICATED
120V CIRCUIT TVSS
M M
TELEPHONE
CONNECTION
EXTERIOR FIRE ALARM
BELL CIRCUIT
C O
M M
O N
S U
PE
R
VI
SO
R Y
SI
G
N
AL
C O
M M
O N
T R
O U
BL
E
SI
G
N
AL
M
NOTIFICATION
APPLIANCE CIRCUIT
x1 x17 x14 x6
O
PT
IC
AL
F
LA
M E
D
ET
EC
TO
IN
H
IB
IT
ED
S
U
PE
R
VI
SO
R
Y
REMOTE POWER SUPPLY
DEDICATED
120V CIRCUIT TVSS
x10 F x2
NOTIFICATION APPLIANCE
CIRCUIT
x9
WP
REMOTE
ANNUNCIATOR
RADIO
TRANSMITTER
DEDICATED
120V CIRCUIT TVSS
C
H
VL
S
FA
N S
H U
T D
O W
N
M
FU
EL
C O
N
TA
IN
M
EN
T
TA
N
K
LE
VE
L
M
TE
M
PE
R
AT
U
R E
M O
N
IT
O R
IN
G
S
EN
SO
R
RTS
D x3 C
H
VA
C U
N
IT
S H
U
TD
O W
N x3x2
NOTIFICATION APPLIANCE
CIRCUIT
x9
TO BUILDING MANAGEMENT
SYSTEM (BMS/EMSC). REFER
TO MECH. PLANS FOR
LOCATION
NOTIFICATION APPLIANCE
CIRCUIT
x4
DIRECTIONAL LOUD SPEAKERS
CO
x3
RTS
FMCP RADIO TRANSMITTER SCHEDULE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALARM - MANUAL FIRE ALARM STATION
ALARM - WATERFLOW
ALARM - RSFACU ALARM SIGNAL
ALARM - SMOKE DETECTOR
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
ALARM - CARBON MONOXIDE
SUPERVISORY - COMMON SUPERVISORY
TROUBLE - COMMON TROUBLE
TROUBLE - MNS OVERRIDE OF FA SYSTEM
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SUPERVISORY - OPTICAL FLAME DETECTION INHIBITED
SPARE
TO FIRE
STATION 859
x1
D
CO
x3
WP
x2 x3
WP
x1
WP
SPARE
SPARE
SPARE
x3
SPARE
EOL
EOL
EOL
EOL
EOL
A
A
A
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
6/ 2/
:1
6:
P M
C :\U se rs
\B
EN
.S H
AF
FE
R \D oc um en ts
\3
-1
8.
-F
-C en tra l-2
0_
BE
N
.S H
AF
FE
R .rv t
M
IC
H
IG
AN
A
IR
N
AT
IO
N
AL
G U
AR
D
W
IL
BU
R W
R
IG
H T
BL
VD
H
AR
R
IS
O
N T
W P, M
IC
H
IG
AN
AD
AL
F U
EL
C
EL
L
C
O R
R O
SI
O
N C
O N
TR
O
L -B
LD
G
F-603
FIRE ALARM SYSTEM
RISER DIAGRAM
VGLZ162323ANG NO.:
3141700-184848.01
RAB
RDV
December 16, 2022
RAB
NTS1 FIRE ALARM/ MNS RISER DIAGRAM
GENERAL NOTES
A. FOR FIRE PROTECTION GENERAL NOTES, LEGEND, &
ABBREVIATIONS, SEE SHEET F-001.
B. THE CONTRACTOR SHALL PROVIDE DETAILED POINT TO
POINT WIRING DIAGRAMS WITH UNIQUE DEVICE NAMES
FOR EACH FIRE ALARM DEVICE.
C. EACH NOTIFICATION APPLIANCE CIRCUIT SHALL INCLUDE
A MINIMUM 25% SPARE CAPACITY.
D. ALL TVSS SHALL BE UL 1449 AND UL 1263 LISTED.
12/16/22 TYPE B3 FINAL
FIRE ALARM CONTROL
PANEL (FACP)
BATTERIES
SIGNALING
LINE CIRCUIT
DEDICATED
120V CIRCUIT TVSS
M M
EXTERIOR FIRE ALARM
BELL CIRCUIT
M x1 x14x2 F
RADIO
TRANSMITTER
DEDICATED
120V CIRCUIT TVSS
NOTIFICATION APPLIANCE
CIRCUIT
x2
M
K
TO FIRE
STATION 859
SIGNALING
LINE CIRCUITM
x3
TVSSTVSS
TANK MONITOR
MODULES
CO
x2
M x3
HEAT TRACE MONITOR
MODULES
H
M M M M M
FI
R
E
PU
M P
R U
N N
IN
G
LO
SS
O F
PH
AS
E
PH
AS
E R
EV
ER
SA
L
C O
N
TR
O
LL
ER
C
O N
N
EC
TE
D
T O
A
LT
ER
N
AT
E
SO
U
R C
E
AL
TE
R N
AT
E
SO
U
R C
E C
IR
C
U
IT
B R
EA
KE
R O
PE
N
C O
M M
O N
T R
O U
BL
E
FIRE PUMP
CONTROLLER
M M M M M M
FI
R
E
PU
M P
R U
N N
IN
G
LO
SS
O F
PH
AS
E
PH
AS
E R
EV
ER
SA
L
C O
N
TR
O
LL
ER
C
O N
N
EC
TE
D
T O
A
LT
ER
N
AT
E
SO
U
R C
E
AL
TE
R N
AT
E
SO
U
R C
E C
IR
C
U
IT
B R
EA
KE
R O
PE
N
C O
M M
O N
T R
O U
BL
E
FIRE PUMP
CONTROLLER
A
EOL
EOL
A
A
A
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, Suite 100, Ann Arbor, MI 48108 phone: 810-956-9300
6/ 2/
:1
8:
P M
C :\U se rs
\B
EN
.S H
AF
FE
R \D oc um en ts
\3
-1
8.
-F
-F P-
C en tra l-2
0_
BE
N
.S H
AF
FE
R .rv t
M
IC
H
IG
AN
A
IR
N
AT
IO
N
AL
G U
AR
D
W
IL
BU
R W
R
IG
H T
BL
VD
H
AR
R
IS
O
N T
W P, M
IC
H
IG
AN
AD
AL
F U
EL
C
EL
L
C
O R
R O
SI
O
N C
O N
TR
O
L -B
LD
G
F-605
B158 FIRE ALARM
SYSTEM RISER
DIAGRAM
VGLZ162323ANG NO.:
3141700-181848.01
RAB
RDV
December 16, 2022
RAB
NTS1 FIRE ALARM RISER DIAGRAM
A. FOR FIRE PROTECTION GENERAL NOTES, LEGEND, &
ABBREVIATIONS, SEE SHEET F-001.
B. ACTUAL NUMBER OF DEVICES PER NOTIFICATION
APPLIANCE CIRCUT SHALL BE DETERMINED BY THE
FIRE ALARM CONTRACTOR'S DETAILED VOLTAGE AND
BATTERY DROP CALCULATIONS.
C. THE CONTRACTOR SHALL PROVIDE DETAILED POINT
TO POINT WIRING DIAGRAMS WITH UNIQUE DEVICE
NAMES FOR EACH FIRE ALARM DEVICE.
D. EACH NOTIFICATION APPLIANCE CIRCUIT SHALL
INCLUDE A MINIMUM 25% SPARE CAPACITY.
E. ALL TVSS SHALL BE UL 1449 AND UL 1263 LISTED.
F. PROVIDE FIRE ALARM CONTROL PANEL COMPATIBLE
WITH BASE WIDE SIMPLEX SYSTEM.
GENERAL NOTES
12/16/22 TYPE B3 FINAL
ADAL Fuel Cell & Corrosion Control, Bldg. 154
VGLZ162323
ADDENDUM 01
02 JUN 2023
PROJECT TABLE OF CONTENTS Page 1
PROJECT TABLE OF CONTENTS
VOLUME 1
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
00 31 32 GEOTECHNICAL DATA
00 31 32A GEOTECHNICAL REPORT
00 31 33 LAND USE AND SOIL CONTROL DOCUMENTATION
00 31 33A SOIL RELOCATION GUIDANCE FOR SELFRIDGE ANGB
00 31 33B CROCK WELLS AND GROUNDWATER WELLS GUIDANCE FOR
SELFRIDGE ANGB
00 31 33C FINAL DD – SITE 7
00 31 33D 2003JUNE20 – IRP SITES 3, 6, 7, 9, 12, 13, 15, 19,
31, AND 36
DIVISION 01 - GENERAL REQUIREMENTS
01 00 00 GENERAL REQUIREMENTS
SUPPLEMENT 1 – VETTING FORM
SUPPLEMENT 2 – SUBMITTAL REGISTER
SUPPLEMENT 3 – AF FORM 3000 – MATERIAL APPROVAL SUBMITTAL
SUPPLEMENT 4 – REQUEST FOR INFORMATION
SUPPLEMENT 5 – AF FORM 3064 – CONTRACT PROGRESS SCHEDULE
SUPPLEMENT 6 – AF FORM 3065 – CONTRACT PROGRESS REPORT
SUPPLEMENT 7 – NOT USED
SUPPLEMENT 8 – SAMPLE – SPARE MATERIAL/PARTS LISTING
SUPPLE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .