W15QKN-15-R-0240 Question Set # 3 Response:
1) Multiple Questions on the MLRS TDP:
a. Attachment 0015 IAC Integration Spares lists part number 12555540 Personal Access Doors Installation as one of the spares. This part number does not match the part number (12620750 Personal Access Doors Installation) listed in the M270A1 Improved Armor Cab data package. Please clarify the requirement for the IAC Integration Spares.
Response: Attachment 0015, IAC Integration Spares, and the spares CLINs currently list the part number for the Personnel Access Doors Installation as 12555570. The correct part number for the Personnel Access Doors Installation is 12620750. Attachment 0015 and the spares CLINs will be corrected in an amendment to the RFP.
b. Attachment 0015 IAC Integration Spares and Attachment 0020 IAC Fielding Spares lists part number 57K6333 600HP Power Unit Replacement Hardware Kit as one of the spares. This drawing was not included in the download and the part number does not match the part number (57K6653 600HP Power Unit Replacement Hardware Kit) listed in the M270A1 Improved Armor Cab data package. Please clarify the requirement for the IAC Integration Spares and IAC Fielding Spares.
Response: The correct part number for the 600HP Power Unit Replacement Hardware Kit is 57K6653. Drawing 57K6653 is included in the TDP download. Attachment 0015, IAC Integration Spares, and Attachment 0020, IAC Fielding Spares, both incorrectly list the part number for the 600HP Power Unit Replacement Hardware Kit as 57K6333. Attachment 0015 and Attachment 0020 will be corrected in an Amendment 0001 to the RFP.
c. Missing Drawing List for MLRS Part Number/Description/Notes:
3233672/SPLICE/MISSING DRAWING; 8724495/SHELL/MISSING DRAWING;
12555560/INSTALLATION INSTRUCTIONS, RADIO AND INTERCOM, MODIFICATION KIT 57K7912/MISSING DRAWING;
13215701/CABLE ASSY, W70I/MISSING PARTS LIST; 13215702/CABLE ASSY, W702/MISSING PARTS LIST; 13215703/CABLE ASSY, W703/MISSING PARTS LIST; 13215704/CABLE ASSY, W704/MISSING PARTS LIST.
Response:
Part Number 3233672 (Splice) does not reference a Government drawing. This splice is a Tyco commercial part (CAGE Code 00779).
Part number 8724495 is defined on drawing 8338566, which is included in the TDP download.
Drawing 12555560 is not a valid IAC drawing. The Radio and Intercom Mod Kit drawing 57K7912 incorrectly references 12555560 in Note 3. The correct Radio and Intercom Mod Kit Installation Instructions drawing is 12555600, which is included in the TDP download.
13215701 Parts List, 13027502 Parts List, 13215703 Parts List and 13215704 Parts List are missing and will be provided to offerors that have compiled with the solicitation’s limited distribution documents requirements.
Attachment 0023 Drawing Addendum will be incorporated thru Amendment 0002.
2) Can the Government provide technical data for the list of GFP being made available in Section H-4? Without drawings of what these items are, bidders will not know for sure whether these items will be usable for their specific manufacturing approach.
Response: Yes, a Section J Attachment will be incorporated in solicitation Amendment 0001.
3) Multiple Questions:
a. CDRL A032, Integrated Program Management Report, references SOW 3.5.6. There is no section 3.5.6 in the SOW. Please indicate whether or not that CDRL is required. If it is, what section of the SOW should it reference.
Response: CDRL A032 is required and should reference SOW paragraph 3.5.5. Update Exhibit A provided in Amendment 0001
b. Can you please provide the following missing drawings from the TDP: 12577549, 12299356, and 12555416.
Response: Drawing 12577549 is not a valid drawing number for IAC, and will be removed in Revision C of the IAC Mod Kit drawing tree in an amendment to the RFP. The reference to 12577549 in Section F-F on sheet 5 of drawing 12556235 is incorrect, and should reference the legacy reused bracket 12299096.
Drawing 12299356 is included in the TDP download.
Drawing 12555416 is not a valid drawing number for IAC, and has been deleted in drawing 57K6763_B_NOR 5 OF 48, which is included in the TDP download.
c. Can you please provide either a print or an NSN number for the following COTS items: PSA- 8, RC864UP, RD167UF, RD737U, SFR10-32x13/16-2615, and X64750.
Response:
The supplier for each COTS item is identified by CAGE Code on the parts list.
The COTS circuit breaker PSA-8 does have an NSN: 5925-01-467- 2117. The other 5 COTS parts referenced in the question do not currently have an NSN.
RC864UP is a typo. The part number listed in the parts list on drawing 12555732 is RC864UF.