Overview-2
| Category | Sub Category | Product | V1 | V1+ | V2 | V3 |
| Cables | ||||||
| Cables and Accessories | ||||||
| Cables | X | X | X | X | ||
| Other Accessories | X | |||||
| Communication Equipment | ||||||
| Communication Devices | ||||||
| Radios | X | X | X | X | ||
| Antennas | X | X | X | X | ||
| Phones | X | X | ||||
| Other Communication | X | X | X | X | ||
| Teleconferencing | X | X | X | X | ||
| Peripherals | ||||||
| Peripherals | ||||||
| Displays | X | X | ||||
| Other Peripherals | X | X | ||||
| Keyboard | X | |||||
| Docking Station | X | X | ||||
| Media Interface | X | |||||
| DVD Writer/Recorder | X | X | ||||
| Mice | X | |||||
| Printers | X | X | ||||
| Optical Drive | X | X | X | |||
| Installation Kits | ||||||
| Transit/Carrying Cases | ||||||
| Installation Kits | X | X | X | |||
| Computer | ||||||
| Laptop | X | X | X | |||
| Handheld | X | X | X | |||
| Workstation | X | X | X | |||
| Simulator | X | |||||
| Desktops | X | X | X | |||
| Software | ||||||
| Licenses | X | |||||
| Operational Transit Case (OTC) | ||||||
| OTC | ||||||
| Low Complexity | X | X | X | |||
| Medium Complexity | X | X | X | |||
| High Complexity | X | X | X | |||
| Power Supplies | ||||||
| Network Appliances, Servers, Storage Appliances, Workstations (A/C or D/C) | ||||||
| Test Equipment/First Article Test (FAT) | X | X | X | |||
| Other Network Equipment | X | X | X | |||
| Server | X | X | X | |||
| Other Computers | X | X | X | |||
| Power Inverter | X | X | X | |||
| Workstations | X | X | X | |||
| Modem | X | X | X | |||
| Storage Devices | X | X | X | |||
| Storage | ||||||
| RAID | X | X | X | |||
| Solid State Drive (SSD) | X | X | X | |||
| Internal Hard Drive | X | X | X | |||
| External Hard Drive | X | X | X | |||
| Routers/ Switches/ Firewall/ Media Converter | ||||||
| Network Devices | ||||||
| Routers | X | X | X | |||
| Security Appliances | X | X | X | |||
| Network Appliance | X | X | X | |||
| Network Adapter | X | |||||
| Switches | X | X | X | |||
| Firewall Appliances | X | X | X | |||
| Servers | X | X | X | |||
| Server Chassis | X | X | X | |||
| Media Converters | X | X | X | |||
| Special Purpose Boards | ||||||
| Video Card | X | X | ||||
| Sound Card | X | X | ||||
| Network Interface Card | X | X | ||||
| Transit/Storage Cases | ||||||
| Unpopulated | ||||||
| Populated | Other Cases | X | X | X | ||
| Transit Cases | X | X | X | |||
| Carry Cases | X | X | X | |||
| Uninterruptible Power Supplies (UPS)/ Power Converter and Conditioner (PCC) | ||||||
| Peripherals | ||||||
| UPS | X | X | ||||
| PCC | X | X | ||||
| Modules | ||||||
| Memory/RAM | X | |||||
| Power | X | |||||
| Networking | X | |||||
| Computer | X | |||||
| Batteries | ||||||
| Laptop Battery | X | |||||
| UPS Battery | X | |||||
| Handheld Device Battery | X | |||||
| Enclosures/Cabinet for IT & Rackmount | ||||||
| Enclosures | X |
Overview
| V-2 and OTC Equipment Production List | |
| Category | Comments |
| Cables | See Attachment A |
| Communication Equipment | See Attachment A |
| Displays | See Attachment A |
| Handheld | See Attachment A |
| Hard Drives | See Attachment A |
| Installation Kits | See Attachment A |
| Consumables | See Attachment A |
| Laptop | |
| Licenses | See Attachment A |
| Operational Transit Cases | |
| Phones | See Attachment A |
| Power Supplies | See Attachment A |
| Printers | See Attachment A |
| Routers/Switches/Firewall/Media Converter | See Attachment D |
| Servers | See Attachment A |
| Special Purpose Boards | See Attachment A |
| Appliances | See Attachment A |
| Transit/Storage Cases Unpopulated | See Attachment A |
| Transit/Storage Cases Populated | See Attachment A |
| Uninterruptible Power Supplies (UPS)/ Power Conversion/Converter (PCC) | See Attachment A |
| Workstations | See Attachment A |
V2 Laptop
| Miltope Rugged Notebook | |
| OEM Part # | 860103 |
| FormFactor | Laptop/Workstation ( fully rugged) |
| BIOS/Chipset | secure BIOS and ability to password protect BIOS |
| EFI/UEFI | ver 2.3.1 or later |
| Processor | Intel® Core i7-4610M 3.0GHz or better (Quad Core) |
| Memory | 8GB DDR3 to 16 GB DDR3 |
| Hard Drive | 500GB to 1TB SED Hard Drive and SPARE Hard Drive with TRAY |
| Optical Drive | Double Layer Internal DVD+-RW Drive (8.5 GB DVD+R DL compatable) |
| Video | NVIDIA 745M or Higher (dedicated graphics with 2GB onboard memory) |
| Display | 15+ TFT LCD FHD 1920x1080 sunlight readable display |
| Keyboard | Backlit Waterproof Full size Keyboard w/ touchpad |
| Interfaces | I/O |
| 1x HDMI 1.3 | |
| 1x Audio Out (mini-jack) | |
| 1x Microphone (mini-jack) | |
| 2x USB 3.0 | |
| 2x USB 2.0 | |
| 1x ExpressCard | |
| 1x SmartCard w/ token reader | |
| 2x 10/100/1000 Ethernet | |
| Power Supply | AC adapter |
| Battery | 1 hour max usage |
| Size | 16" x 12" x 4" |
| Weight | <18 labs with power adatper |
| OS | AGM7 or No OS |
| TPM | TPM 2.0 (TPM 1.2 upgrade to TPM 2.0 must be supported) |
| Transit Case | Add Transit Case with foam insert to fit computer and accessories |
| Spare Items | accessories: HDD with HD Tray, Batteries, AC adapters |
| Cables | DC power cable for vehicle integration (28VDC) |
| Grounding | Ground lug (external chassis) |
| Environmental | |
| Temperature, Operating: The System and optional accessories shall be fully operational in temperatures ranging from -18°C to +49°C (0°F to +120°F). | |
| Temperature, Non-Operating: The System shall be fully operational after being exposed (while in a fully loaded hard transit case) to temperatures ranging from –32°C to +71°C (-25°F to +160°F). | |
| Shock, Operating: The System shall conform to the specified performance requirements while being operated during exposure to nine half-sine shock pulses of 30Gs, 11-millisecond (ms) duration, in each of 3 mutually perpendicular axes. | |
| Shock, Non-Operating: The performance of the System with primary battery and HDD shall not be degraded after being dropped 36 inches. | |
| The HDD performance shall not be degraded after being dropped 36 inches as a stand-alone unit outside the System. | |
| Altitude: The System shall conform to the specified performance requirements while being operated during exposure to altitude conditions of 12,500 feet. The System shall conform to the specified performance requirements prior to and after non-operating exposure to an altitude of 30,000 feet. | |
| The System with all accessories installed shall conform to the specified performance requirements while being operated during exposure to blowing rain at a rate of 1.8 inches per hour with 20 mph wind and a droplet size of 3 mm. | |
| Humidity, Operating: The System with all accessories installed shall conform to the specified performance requirements while being operated during exposure to conditions ranging from 10% to 95% relative humidity. | |
| The System shall show no signs of corrosion after being exposed to a 5 ± 1% aqueous salt atmosphere. | |
| The System & external power adapter (if required) shall conform to the specified performance requirements while being operated during exposure to the sand and dust environment specified below: Sand: 20 mph ± 3mph for 30 minutes per surface, concentration –2.2 ± -0.5g/m3 | |
| Dust: 20 mph ± 3mph for 30 minutes per surface, concentration – 10.6 ± -.7g/m3. |
| Electromagnetic Effects |
| Radiated Emissions: The System with the primary battery, HDD, external power converter (as necessary) shall meet the radiated emissions as defined in MIL-STD-461E, paragraphs 5.15 (RE101) using the Army curve, Figure RE101-1 and 5.16 (RE102) using the helicopter curves, Figure RE102-3 |
| Radiated Susceptibility: The System with primary battery, HDD, external power converter (as necessary) shall conform to the specified performance requirements while being operated during exposure to radiated electric fields as defined in MIL-STD-461E, paragraphs 5.19 (RS103). The Ground System limit level and frequency range of 2 MHz to 18 GHz are applicable for the System in the RS103 environment |
| Conducted Emissions: The System with primary battery, HDD, external power converter(as necessary) shall conform to the specified performance requirements while being operated during exposure to the conducted emissions environment as defined in MIL-STD-461E, paragraphs 5.4 (CE101), Figure CE101-4 and 5.5 (CE102). |
| Conducted Susceptibility: The System with primary battery, HDD, external power converter(as necessary) shall conform to the specified performance requirements while being operated during exposure to the conducted susceptibility environments as defined in MIL-STD-461E, paragraphs 5.7 (CS101), 5.12 (CS114) using limit curve #3, 5.13 (CS115), and 5.14 (CS116), Figure CS116-2, Note 1, Army Procurements. |
| Electrostatic Discharge: The System with the primary battery, , HDD, external power converter(as necessary) shall conform to the specified performance requirements while being operated during exposure to the personnel-borne electrostatic discharge environment as defined in MIL-STD-464A, paragraph 5.7.3. |
| Safety |
| The System and external power adapter (if required) shall meet the safety requirements of IEC 61010. |
| The hottest point (which is exposed to an operator) on the System and any optional items shall not exceed 120 degrees Fahrenheit (or the ambient air temperature if greater than 120 degrees Fahrenheit) per MIL-STD-1472F. |
| For safety ground, all accessible surfaces of the equipment shall be at ground potential. |
| The power cable shall include a safety ground conductor. |
| Quality & Reliability |
| The System will be manufactured in an environment having a Quality Control System meeting or exceeding the applicable requirements of MIL-I-45208 and ISO 9001:2008. This includes supplier control, receiving inspection, process control, in-process and final inspection, test, and shipping. |
| Reliability Mean Time Between Failure (MTBF): The System shall have a minimum MTBF of 2500 hours. |
| Verification: The vendor will make certification (test results, etc.) of the above minimum performance parameters available prior to initial procurement. |
V1 OTC High Comp
| Product Description | MFG Part Number | QTY | |||
| NetOps VSS (Virtual Server Switch) OTC | TBD | 1 | |||
| Dell R420xr Component | |||||
| 2 | Data Interfaces | ||||
| PowerEdge R420xr, Intel Xeon E-24XX v2 Processors | 210-ACET | 1 | The Operational Transit Case Assembly, Colorless NetOps Virtual Server Stack has the following Signal Entry Panel Interfaces: | ||
| Components | · (3) Ethernet/RJ45 ports (plugged into ports 2-4 on SEP and ports 1-3 on switch) | ||||
| PowerEdge R420 Motherboard, TPM | 329-BBXI | 1 | · (1) Serial/RJ45 Console port (plugged into port 1 on SEP and Console Port on switch) | ||
| Dell Hardware Limited Warranty Plus On Site Service 39 Months OEM | 966-6306 | 1 | · (1) 100base-FX/TFOCA II interface (plugged into 100base-FX/TFOCA II interface on switch) | ||
| Basic Hardware Services OEM: Business Hours (5X10) Next Business Day On Site | |||||
| Hardware Warranty Repair 39 Months | 966-6309 | 1 | · (1) 1000base-LX/TFOCA II interface (plugged into 1000base-FX/TFOCA II interface on switch) | ||
| Declined recommended ProSupport service - Call your Dell Sales Rep if Upgrade | |||||
| Needed | 996-8029 | 1 | Power Interfaces | ||
| On-Site Installation Declined | 900-9997 | 1 | The Operational Transit Case Assembly, Colorless NetOps Virtual Server Stack is capable of nominal 120/240 VAC, 50/60 Hz operation, and shall have an internal and external ground point with wing nut. | ||
| US Order | 332-1286 | 1 | Cables | ||
| OEM PowerEdge R420xr Shipping | 340-AGSU | 1 | The OTC Assembly, Colorless NetOps Virtual Server Stack includes the following external cables: | ||
| Dell Branded, Shipping Material/Package, PowerEdge R420xr | 340-AINO | 1 | · One (1) DB9 to RJ45 Serial Cable (Brocade) (plugged into RJ45 port 1 on SEP) | ||
| PCIE Riser for Chassis with 2 Proc | 331-7125 | 1 | · One (1) 6ft Power Cord with NEMA 5-15P plug (part of UPS) | ||
| On-Board LOM 1GBE (Dual Port for Racks and Towers, Quad Port for Blades) | 430-4715 | 1 | · One (1) External Ground Strap | ||
| Intel Ethernet I350 QP 1Gb Server Adapter, Low Profile | 430-4442 | 1 | · Eight (8) Ethernet/RJ45 cables from ports 4-11 on switch to link ports 1-8 on Dell R420xr server) | ||
| Intel X520 DP 10Gb DA/SFP+ Server Adapter | 430-4445 | 1 | · One (1) Ethernet/RJ45 cable from port 14 on switch to iDrac port on Dell R420xr server | ||
| iDRAC Port Card | 421-5340 | 1 | · Two (2) Ethernet/RJ45 cable from port 12 and 13 on switch to LAN ports 1 and 2 on Dell R420xr server | ||
| iDRAC7 Enterprise | 421-6085 | 1 | |||
| Chassis with up to 4, 2.5" Hot Plug Hard Drives, OEM R420xr | 321-BBGO | 1 | |||
| Brand/Bezel, Standard OS, Dell Branded, PowerEdge R420xr | 325-BBFE | 1 | |||
| Performance BIOS Setting | 330-3492 | 1 | |||
| RAID 1 for H710P/H710/H310 (2 HDDs) | 331-7175 | 1 | |||
| PERC H310 Integrated RAID Controller | 342-3528 | 1 | |||
| Heat Sink,PowerEdge | 317-9826 | 1 | |||
| Intel Xeon E5-2470 v2 2.40GHz, 25M Cache, 8.0GT/s QPI, Turbo, 10C, 95W, Max Mem | |||||
| 1600MHz | 338-BDWI | 1 | |||
| Heat Sink,PowerEdge | 317-9826 | 1 | |||
| Intel Xeon E5-2470 v2 2.40GHz, 25M Cache, 8.0GT/s QPI, Turbo, 10C, 95W | 374-BBFM | 1 | |||
| 16GB RDIMM, 1600MT/s, Low Volt, Dual Rank, x4 Data Width | 319-1812 | 12 | |||
| 1600MT/s RDIMMS | 331-4424 | 1 | |||
| Performance Optimized | 331-4428 | 1 | |||
| 200GB Solid State Drive SATA Value MLC 3Gbps 2.5in Cabled Drive-Limited Warranty | 342-5796 | 2 | |||
| Enterprise Value SATA SSD drives assume system warranty up to 3 years - not | |||||
| extendable beyond 3 years | 469-1615 | 2 | |||
| Electronic System Documentation and OpenManage DVD Kit for R420 | 331-7129 | 1 | |||
| No Internal Optical Drive | 313-8574 | 1 | |||
| 2/4-Post Static Rails | 331-4764 | 1 | |||
| Dual Hot Plug Power Supplies 550W | 331-7131 | 1 | |||
| Power Cord, NEMA 5-15P to C13, 15 amp, wall plug, 10 feet / 3 meter | 310-8509 | 2 | |||
| Internal Dual SD Module | 331-4441 | 1 | |||
| 1GB SD Card for RIPS | 342-3595 | 2 | |||
| Enable Redundant SD Cards | 468-4612 | 1 | |||
| No Operating System | 420-6320 | 1 | |||
| No Media Required | 421-5736 | 1 | |||
| OEM Solutions Program Support | 927-3179 | 1 | |||
| ProSupport - Federal On-Site IT Support | 937-5149 | 13 | |||
| 4 GB Micro SDHC Class 10 Flash Card | A4864008 | 2 | |||
| Brocade ICX 6610 Component | CHS P/N: 02-2855767-1 | 1 | |||
| V1+ Brocade ICX 6610 Switch with 48 port 1G RJ45 PoE+, plus 8 x 1G SFPP uplinks ports(upgradeable to 10G). 4 x 40G stacking ports. Exhaust air flow. premium S/W | ICX6610-48P-PE | 1 | |||
| Components | |||||
| License to upgrade 4 ports of 1G SFPP uplink to 10G speeds | ICX6610-10G-LIC-POD | 2 | |||
| 1000Base-LX SFP optic, SMF, LC connector, Optical Monitoring Capable | E1MG-LX-OM | 2 | |||
| DIRECT ATTACHED SFPP ACTIVE COPPER, 1 M, 1-Pack | 10G-SFPP-TWX-0101 | 1 | |||
| DIRECT ATTACHED SFPP ACTIVE COPPER, 3 M, 1-Pack | 10G-SFPP-TWX-0301 | 1 | |||
| 10GBASE-SR, SFP+ optic (LC), target range 300m over MMF | 10G-SFPP-SR | 1 | |||
| OTC Components | |||||
| Signal Entry Panel (SEP) | 1 | ||||
| SEP I/O | 1 | ||||
| TFOCA II Interfaces | 2 | ||||
| RJ45 Interfaces | 31 | ||||
| Power Entry Panel (PEP): 15A Circuit Breaker, 2 NEMA 5-15R Front, 8 NEMA 5-15R Rear, 6 Foot Power Cord with a NEMA 5-15P. The PEP is rated to protect against surges up to 330V. Front and Rear ground studs. Used on other existing OTC’s. 2 NEMA 5-15R’s are accessible at the front of the Transit Case. | 1 | ||||
| Dimensions: (5U)13.1”H x 22.5”W x 36.7”D | 1 | ||||
| NetOps RAID OTC | TBD | 1 | Data Interfaces | ||
| NetApp FAS2552 Component | The Operational Transit Case Assembly, Virtual RAID has the following Signal Entry Panel Interfaces: | ||||
| FAS2552,HA,24x900GB,10G,CTL, Message: PTO Bundles include two 10Gb SFP ( X6589-R6 ) within the first CNA port pair per controller. | FAS2552-R6 | 1 | · One (1) RJ45 Console Port supporting controller 1 of the NetApp FAS2552. | ||
| Hardware | · One (1) RJ45 Console Port supporting controller 2 of the NetApp FAS2552. | ||||
| FAS2552 High Availability | |||||
| System | FAS2552A-001-R6 | 2 | Power Interfaces | ||
| FAS2552,24x900GB,10K,-C | FAS2552-213-R6-C | 1 | The Operational Transit Case Assembly, Virtual RAID is capable of 120/240 VAC (88-264 VAC), 50/60 Hz operation, and shall have an internal and external ground point with wing nut. | ||
| Documents,2552,-C | DOC-2552-C | 1 | Cables | ||
| Power Cable North America,-C,R6 | X800E-R6-C | 2 | The OTC Assembly, Virtual RAID includes the following external cables: | ||
| Cable,Direct Attach CU SFP+ 10G,0.5M | X6566B-05-R6 | 2 | · Four (4) Ethernet/RJ45 Cables | ||
| Rackmount Kit,4-Post,Universal,R6 | X5526A-R6 | 1 | · One (1) External Ground Strap | ||
| OS | · Four (4) SFP+ Direct Attach Cables | ||||
| OS Enable,Per-0.1TB,ONTAP,Perf-Stor,1P,-P | OS-ONTAP-CAP2-1P-P | 216 | |||
| Software | |||||
| SW-2,SnapRestore,2552A,-C | SW-2-2552ASRESTOREC | 2 | |||
| SW-2,CIFS,2552A,-C | SW-2-2552ACIFS-C | 2 | |||
| SW-2,FCP,2552A,-C | SW-2-2552AFCP-C | 2 | |||
| SW-2,iSCSI,2552A,-C | SW-2-2552A-ISCSI-C | 2 | |||
| SW-2,NFS,2552A,-C | SW-2-2552ANFS-C | 2 | |||
| SW-2,SnapMirror-SnapVault | |||||
| Bundle,2552A,-C | SW-2-2552ASM- |
SVLT-BD
| L-C | 2 | ||
| SW-2,Base,CL,Node | SW-2-CL-BASE | 1 | |
| Services | |||
| NetApp SW Subscription Plan | CS-N-SSP | 1 | |
| NetApp SW Subscription Plan Linked Quote: 12096682 | CS-N-SSP | 1 | |
| OTC Components | |||
| Signal Entry Panel (2) RJ45 Console Interfaces) | |||
| Power Entry Panel (PEP): 15A Circuit Breaker, 2 NEMA 5-15R Front, 8 NEMA 5-15R Rear, 6 Foot Power Cord with a NEMA 5-15P. The PEP rated to protect against surges up to 330V. | |||
| Front and Rear ground studs | |||
| External Ground strap | |||
| Dimensions: (3U)9.6”H x 22.5”W x 36.7”D | |||
| 3" front and 5" rear lids with storage pouches | |||
| UPS | |||
| Rugged 1U 1500VA, 1000W Double Conversion Uninterruptible Power Supply(UPS); Auto-Select for Inputs 120 or 240VAC with Output of 120VAC, 50/60Hz; with Power Factor Correction | IHT1500RM-M-1.0kw-DiAC-Isol-120v-4BLiFeHS-1U24 |
File details come from the government source that posted it. Updated .