VCME_NovecSupressionSystem_As-Builts.pdf
PDF 6 MB Posted
- Solicitation number
- 26-B-18LL
- Issued by
- Volusia County, Florida
About this file
This is an as-built drawing document for a Novec-1230 clean agent fire suppression system installed at the Volusia County Medical Examiner's Office in Daytona Beach, Florida, prepared by Fire and Life Safety America under the direction of Curtis Engineering Service, LLC. The document details the complete installation specifications for two protected rooms: Case Files Room 124 (3,240 cubic feet) and Property/Evidence Room 318 (2,390 cubic feet). Room 124 utilizes a 140-pound Novec-1230 cylinder filled with 134 pounds of agent and is designed to achieve a 4.57% predicted concentration with a 9.9-second discharge time, while Room 318 utilizes a 140-pound cylinder filled with 101 pounds of agent to achieve a 4.66% predicted concentration with a 9.4-second discharge time. The system incorporates conventional fire alarm detection with photoelectric smoke detectors, clean agent release control panels (Z-10 model), manual release and abort stations, discharge pressure switches, low-pressure switches, and notification devices including horns, strobes, and alarm bells. All piping utilizes ASTM A-53A Schedule 40 black steel pipe with Class-300 fittings, and the system complies with NFPA standards 101, 72, 70, and 2001, as well as the Florida Building Code and Florida Fire Prevention Code.
The as-built drawing, dated December 19, 2023, and approved June 27, 2022, establishes the baseline design for the Volusia County Medical Examiner's Office clean agent suppression systems that will require ongoing inspection, testing, and maintenance services under the Life Safety Systems contract (Solicitation No. 26-B-18LL). The document provides essential technical reference material for contractors bidding on the comprehensive maintenance and inspection services, including annual fire alarm system testing per NFPA 72 and semi-annual clean agent system inspections per NFPA 2001 requirements. The wiring diagram indicates a conventional system with four relays controlling activation sequences, a 24VDC power supply with battery backup, and integration points for building fire alarm control panels, AHU shutdown, and motorized damper controls. Installation details specify pipe support spacing requirements based on pipe diameter (ranging from 5 feet for 3/8-inch pipe to 17 feet for 6-inch pipe), notification device placement at 80-96 inches from finished floor, and release panel mounting at 70 inches from finished floor. The document confirms all hazards are classified as Class-C in non-normally occupied spaces, with purge equipment not provided and liquid level indicators specified for all cylinders.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOVEC-1230 SYSTEM CONTROLS - D E V I C E S U M M A R Y
SYM DESCRIPTION MODEL
MANUFACT. QTY.
TOTAL
PRE-DISCHARGE HORN/STROBE 433357 1
NOVEC-1230 SUPPRESSION EQUIPMENT - D E V I C E S U M M A R Y
SYM DESCRIPTION MODELMANUFACT. QTY.
TOTAL
ELECTRIC DISCHARGE SOLENOID W/ PLACEMENT INDICATOR 304205030 1ANSUL
LOW PRESSURE SWITCH 570585 1ANSUL
180° NOVEC-1230 NOZZLE - 1ANSULSEE CHART FOR DETAILS
1ANSUL
DISCHARGE PRESSURE SWITCH 437900 1ANSUL
CLEAN AGENT RELEASE CONTROL PANEL (Z-10)
DISCHARGE STROBE 433352 1
ANSUL
ANSUL
430559
433941
428655
CLEAN AGENT ABORT STATION
CLEAN AGENT RELEASE PULL STATION
PHOTOELECTRIC SMOKE DETECTOR W/BASE 430567 ANSUL
ANSUL
ANSUL
CONVENTIONAL 24V RELAY - 20A RESISTIVE @ 277VAC RIB2401B
433937
FUNCTIONAL
ANSUL
430525ANSUL
1st ALARM BELL 417805 1ANSUL
KEYED MAINTENANCE SWITCH
16" TANK MOUNTING BRACKET ASSEMBLY 570092 1ANSUL
CA
CA
CR
MS
Xcd
Xcd
DEVICES
CARP
140 LB NOVEC-1230 CYLINDER W/ 2" VALVE (ROOM 138) 570638ANSULFILLED WITH 101 lbs NOVEC-1230
P
140 LB NOVEC-1230 CYLINDER W/ 2" VALVE (ROOM 124) 570638FILLED WITH 134 lbs NOVEC-1230 134#
101#
QTY.
TOTAL
QTY.
TOTAL
RM 124 RM 318
CLEAN AGENT NOTES:
1. CLEAN AGENT WARNING SIGNS SHALL BE PROVIDED AT
NOTIFICATION DEVICES AND DOORS.
2. USE ASTM A-53A GRADE-A OR B ERW SCHEDULE 40 BLACK PIPE FOR
CLEAN AGENT SYSTEM PIPING.
3. USE CLASS-300 DUCTILE OR MALLIABLE IRON FITTINGS FOR PIPING
SYSTEM.
4. PIPE SIZE REDUCTION MAY BE MADE BY USING REDUCING
TEES/ELBOWS OR CONCENTRIC BELL REDUCERS.
5. APPLY TEFLON TAPE TO ALL MALE THREADS ON SYSTEM PIPING.
6. PROVIDE PIPE SUPPORT WITHIN 12" OF DISCHARGE NOZZLES.
PROVIDE PIPE SUPPORT PER SUPPORT SPACING CHART.
7. INSTALLER TO FIELD VERIFY ALL DIMENSIONS.
8. PURGE EQUIPMENT NOT PROVIDED.
9. ALL HAZARDS ARE CLASS-C.
10. THIS HAZARD IS NOT NORMALLY OCCUPIED.
11. LIQUID LEVEL INDICATORS WILL BE PROVIDED FOR ALL NOVEC-1230
CYLINDERS.
R E V I S I O N S
VO
LU
SI
A
C O
U N
TY
O
FF
IC
E O
F
TH
E D
IS
TR
IC
T
M
ED
IC
A
L
EX
A M
IN
ER
T
IG
ER
B
AY
R
D
D
AY
TO
N
A
BE
AC
H
, F L
DRAWING NO.:
JOB # 22-F-K0012
DATE 5/9/22
DESIGNER C. REVIS
APPROVED C. REVIS
DRAWING TITLE:
E N G I N E E R S E A L
1 6/27/22 C.R.DATE BY
K N
O X
V
IL
LE
, T
N
JA
C K
SO
N
V
IL
LE
, F
L
TA
M
PA
, F L
O R
LA
N
D O
, F L
B A
LT
IM
O R
E, M
D R
IC
H
M O
N D
, V A
R O
A N
O K
E, V
A C
H
ES
A
PE
A K
E, V
A
C H
A R
LO
TT
E, N
C R
A
LE
IG
H
, N C
C H
A R
LE
ST
O N
, S C
TU
LS
A , O
K
SA
N A
N
TO
N
IO
, T X
D A
LL
A
S, T
X H
O U
ST
O
N , T
X
N A
SH
V
IL
LE
, T N
W A
SH
IN
G
TO
N , D
C
A
TL
A N
TA
, G
A B
IR
M
IN
G
H A
M , A
L
Th is d ra w in g is p ro pe rt y of
F ire a nd
L ife
S af et y
A m er ic a an d is n ot to b e du pl ic at ed a nd
/o r di st rib ut ed w ith ou t w rit te n au th or iz at io n fr om F ire a nd L ife S af et y A m er ic a.
f l s a f ir e a n d l if e s a f e t y a m e r ic a p r o t e c t in g a m e r ic a
Fi le
L oc at io n- C
:\A
SH
P R
O
JE
C
TS
\O R
LA
N
D O
\V ol us ia
C ou nt y
M ed ic al
E xa m in er 's
O ff ic e\
FL
SA
D
ES
IG
N
\V O
LU
SI
A C
O U
N
TY
M
ED
IC
A
L
EX
A M
IN
ER
S O
FF
IC
E
- N
O V
EC
S
U
PP
R
ES
SI
O
N fo r R O
O M
S
R
EV
1.
dw g
Pl ot te d-
/1
9/
:2
PM
B y- C hr is
R ev is [F
L- O
R L]
O ld
L ak e M ar y
R d.
S an fo rd
, F L
7)
-1
FA
X
(4
) 6
-4 w w w
.fl sa m er ic a.
co m
NFPA STANDARDS:
#101 (2018 EDITION) - Chapter 19
#72 (2016 EDITION)
#70 (2017 EDITION)
#2001 (2018 EDITION)
C R I T E R I A
TYPE SYSTEM:
CLEAN AGENT FIRE SUPPRESSION
CONVENTIONAL or ADDRESSABLE
S Y S T E M D E S I G N
CIRCUITS CLASS A or CLASS B
Florida Building Code (7th Edition 2020)
MANUFACTURERS REQUIREMENTS
Florida Fire Prevention Code (7th Edition)
SYSTEM
CURTIS ENGINEERING SERVICE, LLC
CA#31561
JAMES M. CURTIS, P.E.
PE#37912
27341 SUNNYSIDE DR.
LEESBURG, FL 34748
RELOCATED CYLINDERS PER EOR COMMENT.
LEGEND & NOTES
FS1 of 6
DESCRIPTION OF WORK:
1. ALL TESTING DONE PER NFPA 72 & NFPA 2001.
2. INSTALL NEW CLEAN AGENT NOVEC-1230 SYSTEM IN CASE FILES RM
124 & PROPERTY EVIDENCE RM 318.
3. WET SPRINKLER HEADS WILL NOT BE INSTALLED IN CLEAN AGENT
PROTECTED ROOMS.
4. CONNECTION FROM RELEASE PANEL TO BUILDING FACP PERFORMED
BY FIRE ALARM CONTRACTOR.
5. EACH CLEAN AGENT SYSTEM IS INDEPENDANT OF EACH OTHER.
SEPARATE CONTROL PANELS.
61GI5-32.008 DESIGN OF FIRE ALARM SYSTEM
(1) Fire alarms and detection systems include fire protection supervision, emergency alarm circuits, activation of life safety system controls and remote signaling of emergency conditions.
Items to be considered in the design or analysis of fire alarm and detection systems are, as applicable to the particular project: occupancy and classification, monitoring, control and communication, cabling and supervision requirements, installation requirements, interoperability and performance requirements.
(2) The design specifications shall be based on the Florida Building Code, the Florida Fire Prevention Code, or as required by the local authority having jurisdiction. The Florida Building Code and the Florida Fire Prevention Code are incorporated by reference in rule 61G15-18.011, F.A.C.
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
INCLUDED
N/A
N/A
N/A N/A N/A N/A N/A N/A
N/A N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A
(3) For systems below the threshold requirements for mandatory use of professional engineering services, the Engineer of Record may specify the minimum system requirements only.
(4) To ensure minimum design quality of Fire Alarm and Detection Systems Engineering Documents, said documents shall include as a minimum the following information when applicable:
(a) The documents shall be clear, with a symbols legend, system riser diagram showing all initiation and notification components, and cabling requirements. The documents shall indicate locations where fire ratings are required as determined by the system's survivability requirements, and shall identify the general occupancy of the protected property and each room and area unless it is clear from features shown.
(b) Locate initiation and notification devices and connections to related systems on the floor plans and sections when needed for clarity. Related systems include elevator controls, smoke control systems, dampers, door release, any other systems or elements directly or indirectly controlled or monitored.
(c) Strobe intensity and speaker output ratings for all notification devices.
(d) Identify the Class of circuits as listed in NFPA 72, which is contained within and incorporated into the Florida Fire Prevention Code.
(e) Identify the functions required by the alarm and control systems including the transmission of emergency signals being monitored or annunciated.
(f) Indicate whether the fire alarm is conventional or addressable, and indicate all zoning.
(g) Locate surge protective devices and required protective features.
(h) Identify and locate system devices that are subject to environmental factors, and indicate requirements for the protection of equipment from temperature, humidity or corrosive atmospheres, including coastal salt air.
(i) The documents shall include a site plan of the immediate area around the protected building, structure or equipment when alarm devices are required outside the structure.
(j) In buildings where smoke detection will be obstructed by walls, beams or ceiling features, the Engineer of Record shall provide applicable design and details to direct the installer to mitigate the obstructions. In buildings with smoke detection under a pitched roof, the plans shall indicate the roof pitch and a building section shall be provided as part of the Engineering Design Documents.
(k) For fire detection systems utilizing smoke detection in situations where smoke stratification is anticipated, the design shall provide the necessary criteria to mitigate the detection problems.
(l) Systems designed using Performance Based criteria shall be identified and referenced to design guides or standards approved by the local authority having jurisdiction consistent with standards adopted by the Florida Fire Prevention Code and the Florida Building Code.
(m) The system design must indicate if the system is to provide a general evacuation signal or a zoned evacuation for all high-rise buildings or multi-tenanted properties as defined in section 2 of the Florida Building Code, Building.
(n) Wiring requirements for underground, wet locations, campus style wiring, protection against damage and burial depth shall be specified or indicated on the engineering design documents.
(o) Requirements for operations and maintenance procedures, manuals, system documentation, and instruction of Owner's operating personnel, as needed to operate the systems as intended over time.
(5) In the event that the Engineer of Record elects to specify specific equipment and to show the required wiring, battery and voltage drop (circuit analysis) calculations shall be completed.
The calculations shall be completed using the equipment manufacture's data and applicable NFPA 72 procedures.
(6) System test requirements shall be noted on the Engineering Design Documents.
(7) When the Engineer of Record determines that special requirements are required by the owner, insurance underwriter or local fire code amendments these requirements shall be documented or referenced on the Engineering Design Documents.
AS-BUILT 12/19/23
AutoCAD SHX Text N
CASE FILES
CARP
IDC1-1
P
CA
SP
M
1-
N 2-
1 75cd
75cd N1-1
N 3-
CA
SP
M
2-
1MS
NOZZLE
IDC2-1
P
IDC2
AA
CR
IDC1
IDC2
SPM1
SPM2
NAC1
IDC3
IDC4
SOL NAC1
24V2
FIELD LOCATE
NEAR MOTORIZED DAMPER
IDC1
IDC2
24V2
FIELD LOCATE
AHU SHUTDOWN
CR
HSKP
4#
2" CORE DRILLED HOLE (X2)
IDC3
IDC4
SOL
12'-23 8"
9'-33 8"
4'
10'-111
2" TO CENTER AFF
RELEASE
PANEL
MAINT. SW.
LEAVE AREA
WHEN ALARM
SOUNDS
BELL:
FIRE SUPPRESSION SYSTEM
FIRST ALARM
HORN/STROBE:
FIRE SUPPRESSION SYSTEM
COUNTDOWN STARTED
SMOKE DET.
140Lb
CLEAN AGENT
PUSH
PULL
NOVEC-1230
SYSTEM
ABORT
W/134#
1'-111 2"
OUTLET
1'-13 4"
STRAP
NOZZLE
9'-51 2"
CASE FILES
CEILING
10'
HSKP
NOZZLE
10'-111 2"
WIRE/CABLE LEGEND
CIRCUIT TAG ID: CABLE TYPE:
NAC1
IDC1 & 2 16AWG 2/C FPLP
NAC2
NAC3
DESCRIPTION:
INITIATING CIRCUIT TO SMOKE DETECTORS (CLASS-B)
RELEASE PANEL NAC1, DISCHARGE STROBE OUTSIDE ROOM
RELEASE PANEL NAC2, HORN/STROBE
RELEASE PANEL RAC2, BELL
RELEASE PANEL:
SOL RELEASE PANEL RAC1, NOVEC-1230 SOLENOID CKT VIA MAINTENANCE SW.
14AWG 2/C FPLP
14AWG 2/C FPLP
14AWG 2/C FPLP
14AWG 2/C FPLP
CONDUIT LINE TYPE:
MULTIPLE CIRCUITS
24V1 AUX 24V TO MAINTENANCE SWITCH LIGHT14AWG 2/C FPLP
24V2 AUX 24V SWITCHED BY PANEL RELAY-3 TO CONV. DAMPER & SHTDN RELAYS14AWG 2/C FPLP
SPM1 ABORT STATION CIRCUIT16AWG 2/C FPLP
SPM2 MANUAL RELEASE STATION CIRCUIT16AWG 2/C FPLP
IDC3 16AWG 2/C FPLP INITIATING CIRCUIT TO DISCHARGE PRESSURE SWITCH
IDC4 16AWG 2/C FPLP SUPERVISORY INITIATING CIRCUIT TO ACTUATOR PLACEMENT & LOW PRES. SW.
CLEAN AGENT NOTES:
1. CLEAN AGENT WARNING SIGNS SHALL BE PROVIDED AT
NOTIFICATION DEVICES AND DOORS.
2. USE ASTM A-53A GRADE-A OR B ERW SCHEDULE 40 BLACK PIPE FOR
CLEAN AGENT SYSTEM PIPING.
3. USE CLASS-300 DUCTILE OR MALLIABLE IRON FITTINGS FOR PIPING
SYSTEM.
4. PIPE SIZE REDUCTION MAY BE MADE BY USING REDUCING
TEES/ELBOWS OR CONCENTRIC BELL REDUCERS.
5. APPLY TEFLON TAPE TO ALL MALE THREADS ON SYSTEM PIPING.
6. PROVIDE PIPE SUPPORT WITHIN 12" OF DISCHARGE NOZZLES.
PROVIDE PIPE SUPPORT PER SUPPORT SPACING CHART.
7. INSTALLER TO FIELD VERIFY ALL DIMENSIONS.
8. PURGE EQUIPMENT NOT PROVIDED.
9. ALL HAZARDS ARE CLASS-C.
10. THIS HAZARD IS NOT NORMALLY OCCUPIED.
11. LIQUID LEVEL INDICATORS WILL BE PROVIDED FOR ALL NOVEC-1230
CYLINDERS.
CASE FILES ROOM 124 - NOVEC-1230 QUANTITY CALCULATIONS
LENGTHS SHOWN ARE FROM
CENTER OF FITTING TO CENTER OF FITTING
NOT CUT LENGTHS
LP SWITCH
ELECTRIC ACTUATOR
PRESSURE SWITCH
DISCHARGE
FELXIBLE PILOT HOSE
ACTUATOR PLACEMENT SW. 441871
140 lbs.
134lbs. FILL
E1-N1
X 0'-9.5"
FABRICATED PIPE CUT LENGTH
3" 1'-2"
C TO C LENGTH
FABRICATED PIPE ID
PIPE DIAMETER
8 8'-10.5"
9 1'-9"
10 1'-4"
R E V I S I O N S
VO
LU
SI
A
C O
U N
TY
O
FF
IC
E O
F
TH
E D
IS
TR
IC
T
M
ED
IC
A
L
EX
A M
IN
ER
T
IG
ER
B
AY
R
D
D
AY
TO
N
A
BE
AC
H
, F L
DRAWING NO.:
JOB # 22-F-K0012
DATE 5/9/22
DESIGNER C. REVIS
APPROVED C. REVIS
DRAWING TITLE:
E N G I N E E R S E A L
1 6/27/22 C.R.DATE BY
K N
O X
V
IL
LE
, T
N
JA
C K
SO
N
V
IL
LE
, F
L
TA
M
PA
, F L
O R
LA
N
D O
, F L
B A
LT
IM
O R
E, M
D R
IC
H
M O
N D
, V A
R O
A N
O K
E, V
A C
H
ES
A
PE
A K
E, V
A
C H
A R
LO
TT
E, N
C R
A
LE
IG
H
, N C
C H
A R
LE
ST
O N
, S C
TU
LS
A , O
K
SA
N A
N
TO
N
IO
, T X
D A
LL
A
S, T
X H
O U
ST
O
N , T
X
N A
SH
V
IL
LE
, T N
W A
SH
IN
G
TO
N , D
C
A
TL
A N
TA
, G
A B
IR
M
IN
G
H A
M , A
L
Th is d ra w in g is p ro pe rt y of
F ire a nd
L ife
S af et y
A m er ic a an d is n ot to b e du pl ic at ed a nd
/o r di st rib ut ed w ith ou t w rit te n au th or iz at io n fr om F ire a nd L ife S af et y A m er ic a.
f l s a f ir e a n d l if e s a f e t y a m e r ic a p r o t e c t in g a m e r ic a
Fi le
L oc at io n- C
:\A
SH
P R
O
JE
C
TS
\O R
LA
N
D O
\V ol us ia
C ou nt y
M ed ic al
E xa m in er 's
O ff ic e\
FL
SA
D
ES
IG
N
\V O
LU
SI
A C
O U
N
TY
M
ED
IC
A
L
EX
A M
IN
ER
S O
FF
IC
E
- N
O V
EC
S
U
PP
R
ES
SI
O
N fo r R O
O M
S
R
EV
1.
dw g
Pl ot te d-
/1
9/
:2
PM
B y- C hr is
R ev is [F
L- O
R L]
O ld
L ak e M ar y
R d.
S an fo rd
, F L
7)
-1
(4
) 6
-4 w w w
.fl sa m er ic a.
co m
NFPA STANDARDS:
#101 (2018 EDITION) - Chapter 19
#72 (2016 EDITION)
#70 (2017 EDITION)
#2001 (2018 EDITION)
C R I T E R I A
TYPE SYSTEM:
CLEAN AGENT FIRE SUPPRESSION
CONVENTIONAL or ADDRESSABLE
S Y S T E M D E S I G N
CIRCUITS CLASS A or CLASS B
Florida Building Code (7th Edition 2020)
MANUFACTURERS REQUIREMENTS
Florida Fire Prevention Code (7th Edition)
SYSTEM
CURTIS ENGINEERING SERVICE, LLC
CA#31561
JAMES M. CURTIS, P.E.
PE#37912
27341 SUNNYSIDE DR.
LEESBURG, FL 34748
RELOCATED CYLINDERS PER EOR COMMENT.
CASE FILES RM 124
PLAN VIEW, NOTES,
ISOMETRIC VIEW
FS2 of 6
CASE FILES ROOM 124 PLAN VIEW
SCALE: 1/2" = 1'-0"
SECTION "AA"
SCALE: 1/2" = 1'-0"
CASE FILES ROOM 124 ISOMETRIC VIEW
AS-BUILT 12/19/23
AutoCAD SHX Text
AutoCAD SHX Text
CYLINDER
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
FILL
AutoCAD SHX Text
NOVEC-1230
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROOM DIMENSIONS
AutoCAD SHX Text
HEIGHT (FT)
AutoCAD SHX Text
ROOM NAME
AutoCAD SHX Text
AREA (FT)
AutoCAD SHX Text (70%%D F)
AutoCAD SHX Text
NOVEC-1230
AutoCAD SHX Text
SUPPLIED
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
AutoCAD SHX Text
140 LB
AutoCAD SHX Text
CYLINDER
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
CONCENTRATION
AutoCAD SHX Text 4.5%%%
AutoCAD SHX Text 10.0
AutoCAD SHX Text 0.04077
AutoCAD SHX Text
FACTOR
AutoCAD SHX Text 3,240
AutoCAD SHX Text
AutoCAD SHX Text
VOLUME (FT)
AutoCAD SHX Text
CASE FILES RM. 124
AutoCAD SHX Text
PREDICTED
AutoCAD SHX Text
CONCENTRATION
AutoCAD SHX Text 4.57%%%
AutoCAD SHX Text
DISCHARGE
AutoCAD SHX Text
(SECONDS)
AutoCAD SHX Text
TIME
AutoCAD SHX Text 9.9
AutoCAD SHX Text
2" SWIVEL ADAPTOR
AutoCAD SHX Text
2" X 1" CONC. BELL REDUCER
AutoCAD SHX Text
ASSMEBLY
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text
1'-0" CNTR TO CNTR
AutoCAD SHX Text
1" 90%%D ELBOW
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
3" DIRT
AutoCAD SHX Text
AutoCAD SHX Text 1"
AutoCAD SHX Text 1'-9"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1'-6"
R E V I S I O N S
VO
LU
SI
A
C O
U N
TY
O
FF
IC
E O
F
TH
E D
IS
TR
IC
T
M
ED
IC
A
L
EX
A M
IN
ER
T
IG
ER
B
AY
R
D
D
AY
TO
N
A
BE
AC
H
, F L
DRAWING NO.:
JOB # 22-F-K0012
DATE 5/9/22
DESIGNER C. REVIS
APPROVED C. REVIS
DRAWING TITLE:
E N G I N E E R S E A L
1 6/27/22 C.R.DATE BY
K N
O X
V
IL
LE
, T
N
JA
C K
SO
N
V
IL
LE
, F
L
TA
M
PA
, F L
O R
LA
N
D O
, F L
B A
LT
IM
O R
E, M
D R
IC
H
M O
N D
, V A
R O
A N
O K
E, V
A C
H
ES
A
PE
A K
E, V
A
C H
A R
LO
TT
E, N
C R
A
LE
IG
H
, N C
C H
A R
LE
ST
O N
, S C
TU
LS
A , O
K
SA
N A
N
TO
N
IO
, T X
D A
LL
A
S, T
X H
O U
ST
O
N , T
X
N A
SH
V
IL
LE
, T N
W A
SH
IN
G
TO
N , D
C
A
TL
A N
TA
, G
A B
IR
M
IN
G
H A
M , A
L
Th is d ra w in g is p ro pe rt y of
F ire a nd
L ife
S af et y
A m er ic a an d is n ot to b e du pl ic at ed a nd
/o r di st rib ut ed w ith ou t w rit te n au th or iz at io n fr om F ire a nd L ife S af et y A m er ic a.
f l s a f ir e a n d l if e s a f e t y a m e r ic a p r o t e c t in g a m e r ic a
Fi le
L oc at io n- C
:\A
SH
P R
O
JE
C
TS
\O R
LA
N
D O
\V ol us ia
C ou nt y
M ed ic al
E xa m in er 's
O ff ic e\
FL
SA
D
ES
IG
N
\V O
LU
SI
A C
O U
N
TY
M
ED
IC
A
L
EX
A M
IN
ER
S O
FF
IC
E
- N
O V
EC
S
U
PP
R
ES
SI
O
N fo r R O
O M
S
R
EV
1.
dw g
Pl ot te d-
/1
9/
:2
PM
B y- C hr is
R ev is [F
L- O
R L]
O ld
L ak e M ar y
R d.
S an fo rd
, F L
7)
-1
(4
) 6
-4 w w w
.fl sa m er ic a.
co m
NFPA STANDARDS:
#101 (2018 EDITION) - Chapter 19
#72 (2016 EDITION)
#70 (2017 EDITION)
#2001 (2018 EDITION)
C R I T E R I A
TYPE SYSTEM:
CLEAN AGENT FIRE SUPPRESSION
CONVENTIONAL or ADDRESSABLE
S Y S T E M D E S I G N
CIRCUITS CLASS A or CLASS B
Florida Building Code (7th Edition 2020)
MANUFACTURERS REQUIREMENTS
Florida Fire Prevention Code (7th Edition)
SYSTEM
CURTIS ENGINEERING SERVICE, LLC
CA#31561
JAMES M. CURTIS, P.E.
PE#37912
27341 SUNNYSIDE DR.
LEESBURG, FL 34748
RELOCATED CYLINDERS PER EOR COMMENT.
CASE FILES RM 124
NOVEC-1230
FLOW CALCULATION
FS3 of 6CASE FILES ROOM 124 - NOVEC-1230 FLOW CALCULATIONS
AS-BUILT 12/19/23
WIRE/CABLE LEGEND
CIRCUIT TAG ID: CABLE TYPE:
NAC1
IDC1 & 2 16AWG 2/C FPLP
NAC2
NAC3
DESCRIPTION:
INITIATING CIRCUIT TO SMOKE DETECTORS (CLASS-B)
RELEASE PANEL NAC1, DISCHARGE STROBE OUTSIDE ROOM
RELEASE PANEL NAC2, HORN/STROBE
RELEASE PANEL RAC2, BELL
RELEASE PANEL:
SOL RELEASE PANEL RAC1, NOVEC-1230 SOLENOID CKT VIA MAINTENANCE SW.
14AWG 2/C FPLP
14AWG 2/C FPLP
14AWG 2/C FPLP
14AWG 2/C FPLP
CONDUIT LINE TYPE:
MULTIPLE CIRCUITS
24V1 AUX 24V TO MAINTENANCE SWITCH LIGHT14AWG 2/C FPLP
24V2 AUX 24V SWITCHED BY PANEL RELAY-3 TO CONV. DAMPER & SHTDN RELAYS14AWG 2/C FPLP
SPM1 ABORT STATION CIRCUIT16AWG 2/C FPLP
SPM2 MANUAL RELEASE STATION CIRCUIT16AWG 2/C FPLP
IDC3 16AWG 2/C FPLP INITIATING CIRCUIT TO DISCHARGE PRESSURE SWITCH
IDC4 16AWG 2/C FPLP SUPERVISORY INITIATING CIRCUIT TO ACTUATOR PLACEMENT & LOW PRES. SW.
CLEAN AGENT NOTES:
1. CLEAN AGENT WARNING SIGNS SHALL BE PROVIDED AT
NOTIFICATION DEVICES AND DOORS.
2. USE ASTM A-53A GRADE-A OR B ERW SCHEDULE 40 BLACK PIPE FOR
CLEAN AGENT SYSTEM PIPING.
3. USE CLASS-300 DUCTILE OR MALLIABLE IRON FITTINGS FOR PIPING
SYSTEM.
4. PIPE SIZE REDUCTION MAY BE MADE BY USING REDUCING
TEES/ELBOWS OR CONCENTRIC BELL REDUCERS.
5. APPLY TEFLON TAPE TO ALL MALE THREADS ON SYSTEM PIPING.
6. PROVIDE PIPE SUPPORT WITHIN 12" OF DISCHARGE NOZZLES.
PROVIDE PIPE SUPPORT PER SUPPORT SPACING CHART.
7. INSTALLER TO FIELD VERIFY ALL DIMENSIONS.
8. PURGE EQUIPMENT NOT PROVIDED.
9. ALL HAZARDS ARE CLASS-C.
10. THIS HAZARD IS NOT NORMALLY OCCUPIED.
11. LIQUID LEVEL INDICATORS WILL BE PROVIDED FOR ALL NOVEC-1230
PROPERTY/
EVIDENCE
IDC1-1
P
IDC2-1
P
C A
R P
CASPM1-1
N2-1 75cd
75cd
N1-1 N3-1
CA
SPM2-1
MS
IDC1
IDC2
24V2
IDC3
IDC4
SOL
NAC1
SPM1
SPM2
NAC1
IDC2
24V2
B B
FIELD LOCATE
NEAR MOTORIZED DAMPER
CR
24V2
IDC2
FIELD LOCATE
AHU SHUTDOWN
CR
HSKP
101#
4"
SHOWER
9'-81 4"
NOZZLE
WALL PENATRATION
MAINTAIN WALL FIRE RATING
140Lb W/101#
1'-111 2"
OUTLET
1'-13 4"
STRAP
CEILING
PROPERTY/
EVIDENCE
NOZZLE
HSKP
SHOWER
30510'
10'-111 2"
SMOKE DET.
PROPERTY/ EVIDENCE ROOM 318 - NOVEC-1230 QUANTITY CALCULATIONS
LENGTHS SHOWN ARE FROM
CENTER OF FITTING TO CENTER OF FITTING
NOT CUT LENGTHS
LP SWITCH
ELECTRIC ACTUATOR
PRESSURE SWITCH
DISCHARGE
FELXIBLE PILOT HOSE
ACTUATOR PLACEMENT SW. 441871
140 lbs.
101lbs. FILL
E1-N1
X 0'-9.5"
FABRICATED PIPE CUT LENGTH
3" 1'-2"
C TO C LENGTH
FABRICATED PIPE ID
PIPE DIAMETER
1 8'-10.5"
2 2'-0"
2 2'-0"
3 6'-3"
4 1'-4"
R E V I S I O N S
VO
LU
SI
A
C O
U N
TY
O
FF
IC
E O
F
TH
E D
IS
TR
IC
T
M
ED
IC
A
L
EX
A M
IN
ER
T
IG
ER
B
AY
R
D
D
AY
TO
N
A
BE
AC
H
, F L
DRAWING NO.:
JOB # 22-F-K0012
DATE 5/9/22
DESIGNER C. REVIS
APPROVED C. REVIS
DRAWING TITLE:
E N G I N E E R S E A L
1 6/27/22 C.R.DATE BY
K N
O X
V
IL
LE
, T
N
JA
C K
SO
N
V
IL
LE
, F
L
TA
M
PA
, F L
O R
LA
N
D O
, F L
B A
LT
IM
O R
E, M
D R
IC
H
M O
N D
, V A
R O
A N
O K
E, V
A C
H
ES
A
PE
A K
E, V
A
C H
A R
LO
TT
E, N
C R
A
LE
IG
H
, N C
C H
A R
LE
ST
O N
, S C
TU
LS
A , O
K
SA
N A
N
TO
N
IO
, T X
D A
LL
A
S, T
X H
O U
ST
O
N , T
X
N A
SH
V
IL
LE
, T N
W A
SH
IN
G
TO
N , D
C
A
TL
A N
TA
, G
A B
IR
M
IN
G
H A
M , A
L
Th is d ra w in g is p ro pe rt y of
F ire a nd
L ife
S af et y
A m er ic a an d is n ot to b e du pl ic at ed a nd
/o r di st rib ut ed w ith ou t w rit te n au th or iz at io n fr om F ire a nd L ife S af et y A m er ic a.
f l s a f ir e a n d l if e s a f e t y a m e r ic a p r o t e c t in g a m e r ic a
Fi le
L oc at io n- C
:\A
SH
P R
O
JE
C
TS
\O R
LA
N
D O
\V ol us ia
C ou nt y
M ed ic al
E xa m in er 's
O ff ic e\
FL
SA
D
ES
IG
N
\V O
LU
SI
A C
O U
N
TY
M
ED
IC
A
L
EX
A M
IN
ER
S O
FF
IC
E
- N
O V
EC
S
U
PP
R
ES
SI
O
N fo r R O
O M
S
R
EV
1.
dw g
Pl ot te d-
/1
9/
:2
PM
B y- C hr is
R ev is [F
L- O
R L]
O ld
L ak e M ar y
R d.
S an fo rd
, F L
7)
-1
(4
) 6
-4 w w w
.fl sa m er ic a.
co m
NFPA STANDARDS:
#101 (2018 EDITION) - Chapter 19
#72 (2016 EDITION)
#70 (2017 EDITION)
#2001 (2018 EDITION)
C R I T E R I A
TYPE SYSTEM:
CLEAN AGENT FIRE SUPPRESSION
CONVENTIONAL or ADDRESSABLE
S Y S T E M D E S I G N
CIRCUITS CLASS A or CLASS B
Florida Building Code (7th Edition 2020)
MANUFACTURERS REQUIREMENTS
Florida Fire Prevention Code (7th Edition)
SYSTEM
CURTIS ENGINEERING SERVICE, LLC
CA#31561
JAMES M. CURTIS, P.E.
PE#37912
27341 SUNNYSIDE DR.
LEESBURG, FL 34748
RELOCATED CYLINDERS PER EOR COMMENT.
PROP/EVIDENCE 318
PLAN VIEW, NOTES,
ISOMETRIC VIEW
FS4 of 6
PROPERTY / EVIDENCE ROOM 318 PLAN VIEW
SCALE: 1/2" = 1'-0"
PROPERTY / EVIDENCE ROOM 318 ISOMETRIC VIEW
SECTION "BB"
SCALE: 1/2" = 1'-0"
AS-BUILT 12/19/23
AutoCAD SHX Text
AutoCAD SHX Text
CYLINDER
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
FILL
AutoCAD SHX Text
NOVEC-1230
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROOM DIMENSIONS
AutoCAD SHX Text
HEIGHT (FT)
AutoCAD SHX Text
ROOM NAME
AutoCAD SHX Text
AREA (FT)
AutoCAD SHX Text (70%%D F)
AutoCAD SHX Text
NOVEC-1230
AutoCAD SHX Text
SUPPLIED
AutoCAD SHX Text
(POUNDS)
AutoCAD SHX Text
AutoCAD SHX Text
140 LB
AutoCAD SHX Text
CYLINDER
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
CONCENTRATION
AutoCAD SHX Text 4.5%%%
AutoCAD SHX Text 10.0
AutoCAD SHX Text 0.04077
AutoCAD SHX Text
FACTOR
AutoCAD SHX Text 2,390
AutoCAD SHX Text
AutoCAD SHX Text
VOLUME (FT)
AutoCAD SHX Text
PROPERTY/EVIDENCE
AutoCAD SHX Text
PREDICTED
AutoCAD SHX Text
CONCENTRATION
AutoCAD SHX Text 4.66%%%
AutoCAD SHX Text
DISCHARGE
AutoCAD SHX Text
(SECONDS)
AutoCAD SHX Text
TIME
AutoCAD SHX Text 9.4
AutoCAD SHX Text
ROOM 318
AutoCAD SHX Text
2" SWIVEL ADAPTOR
AutoCAD SHX Text
2" X 1" CONC. BELL REDUCER
AutoCAD SHX Text
ASSMEBLY
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text
1'-0" CNTR TO CNTR
AutoCAD SHX Text
1" 90%%D ELBOW
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text 1"
AutoCAD SHX Text 10'-7"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text
3" DIRT
AutoCAD SHX Text
R E V I S I O N S
VO
LU
SI
A
C O
U N
TY
O
FF
IC
E O
F
TH
E D
IS
TR
IC
T
M
ED
IC
A
L
EX
A M
IN
ER
T
IG
ER
B
AY
R
D
D
AY
TO
N
A
BE
AC
H
, F L
DRAWING NO.:
JOB # 22-F-K0012
DATE 5/9/22
DESIGNER C. REVIS
APPROVED C. REVIS
DRAWING TITLE:
E N G I N E E R S E A L
1 6/27/22 C.R.DATE BY
K N
O X
V
IL
LE
, T
N
JA
C K
SO
N
V
IL
LE
, F
L
TA
M
PA
, F L
O R
LA
N
D O
, F L
B A
LT
IM
O R
E, M
D R
IC
H
M O
N D
, V A
R O
A N
O K
E, V
A C
H
ES
A
PE
A K
E, V
A
C H
A R
LO
TT
E, N
C R
A
LE
IG
H
, N C
C H
A R
LE
ST
O N
, S C
TU
LS
A , O
K
SA
N A
N
TO
N
IO
, T X
D A
LL
A
S, T
X H
O U
ST
O
N , T
X
N A
SH
V
IL
LE
, T N
W A
SH
IN
G
TO
N , D
C
A
TL
A N
TA
, G
A B
IR
M
IN
G
H A
M , A
L
Th is d ra w in g is p ro pe rt y of
F ire a nd
L ife
S af et y
A m er ic a an d is n ot to b e du pl ic at ed a nd
/o r di st rib ut ed w ith ou t w rit te n au th or iz at io n fr om F ire a nd L ife S af et y A m er ic a.
f l s a f ir e a n d l if e s a f e t y a m e r ic a p r o t e c t in g a m e r ic a
Fi le
L oc at io n- C
:\A
SH
P R
O
JE
C
TS
\O R
LA
N
D O
\V ol us ia
C ou nt y
M ed ic al
E xa m in er 's
O ff ic e\
FL
SA
D
ES
IG
N
\V O
LU
SI
A C
O U
N
TY
M
ED
IC
A
L
EX
A M
IN
ER
S O
FF
IC
E
- N
O V
EC
S
U
PP
R
ES
SI
O
N fo r R O
O M
S
R
EV
1.
dw g
Pl ot te d-
/1
9/
:2
PM
B y- C hr is
R ev is [F
L- O
R L]
O ld
L ak e M ar y
R d.
S an fo rd
, F L
7)
-1
(4
) 6
-4 w w w
.fl sa m er ic a.
co m
NFPA STANDARDS:
#101 (2018 EDITION) - Chapter 19
#72 (2016 EDITION)
#70 (2017 EDITION)
#2001 (2018 EDITION)
C R I T E R I A
TYPE SYSTEM:
CLEAN AGENT FIRE SUPPRESSION
CONVENTIONAL or ADDRESSABLE
S Y S T E M D E S I G N
CIRCUITS CLASS A or CLASS B
Florida Building Code (7th Edition 2020)
MANUFACTURERS REQUIREMENTS
Florida Fire Prevention Code (7th Edition)
SYSTEM
CURTIS ENGINEERING SERVICE, LLC
CA#31561
JAMES M. CURTIS, P.E.
PE#37912
27341 SUNNYSIDE DR.
LEESBURG, FL 34748
RELOCATED CYLINDERS PER EOR COMMENT.
PROP/EVIDENCE 318
NOVEC-1230
FLOW CALCULATION
FS5 of 6PROPERTY / EVIDENCE ROOM 318 - NOVEC-1230 FLOW CALCULATIONS
AS-BUILT 12/19/23
RELAY # 1. ACTIVATES ON ANY TROUBLE
(INCLUDES GENERAL PANEL TROUBLES)
RELAY # 2. ACTIVATES ON ANY ALARM
RELAY # 3. ACTIVATES ON CROSS ZONED
ALARM (PRE-DISCHARGE)
RELAY # 4. ACTIVATES FROM DISCHARGE
PRESSURE SWITCH
FIRE ALARM
CONNECTIONALARM
AUTOPULSE Z10
PROGRAMMED FOR
APP MODE #12
CONTROL PANEL
12V, 12AH BATTERY 12V, 12AH BATTERY
120VAC POWER WIRING
12AWG SOLID
DEDICATED BREAKER
(WIRING & BREAKER BY OTHERS)
TB
L
R
EL
AY
R
EL
AY
R
EL
AY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ID
C
R
AC
R
AC
N
AC
N
AC
ID
C
ID
C
ID
C
ID
C
SP
M
SP
M
+ - RESETABLE
BUILDING
0.
5A
0.
9A
TROUBLE
SUPRVISORY (BY OTHERS)
DAMPER SHTDN
0.14A
0.
5A
R
EDBL
K
YE
L
BL
K
24V ELECTRIC
DISCHARGE
0.2A
MAINTENANCE SWITCH
0.
3A
SOLENOID
X2
LIGHT
X1
R
ED +
16.2K
WHT +
R
ED
BL
K
BL
K
W H
T
BL
K
EPO INTERFACE
COIL
SUPERVISION
MODULE
IDC1-1 P
IDC2-1
P
NAC2-1
75cd75cd
NAC1-1NAC3-1
CASPM1-1 CA SPM2-1
NOVEC-1230 CYLINDER
LOW PRESSURE
SWITCH
SWITCH SHOWN
ATTACHED TO
CYLINDER &
UNDER NORMAL
PRESSURE
DISCH. PRESSURE
SWITCH
ACTUATOR PLACEMENT
INDICATOR SWITCH
N.O.
N.C.
C
ORG
YEL
CR
ORG
YEL
V2
24V1
IDC3
IDC4
AHU SHTDNCR
A Single Photoelectric Smoke Detector Activated More Than One Photoelectric Smoke Detector Activated Manual Release Station
Discharge Abort Station Held
Maintenance Switch NOVEC-1230 Low Pressure Switch or Actuator Placement Indicator Switch AC Power Loss Battery Loss Circuit Fault
Input Signals Alar m Signal t o Building FACP
Trouble S ignal t o Building FACP
Agent R ele ase to
BLDG FACP
Piez o at
Rele ase
Contro l P anel
Clea n Agent D isc harg e
Disc harg e C ountdown Contin ues to
Signals to
CLEAN AGENT
FIRE SUPPRESSION SYSTEM
X
SEQUENCE OF OPERATION
MATRIX
Activ ate s S tro be O utsid e H aza rd
Seco nds & Holds
Countdown Contin ues
From 10 Sec.
X X X
X X XX
*After 30 Second Countdown Has Elapsed.
XX X
XX
Prev ents C lea n Agent D isc harg e
X
X Discharge Abort Station Released X
X X X X X X X X
*X *X *X
Activ ate s B ell
Activ ate s H orn/Stro be S tea dy
X
BLDG FACP Notification Fire Suppres sio n
Abort/Disable Discharge
Discharge Pressure Switch (Activated by NOVEC-1230 Discharge)
X
X X X X Laser Smoke Detector Activated X X X
Superv iso ry Signal t o Building FACP
X
Aux F unctio ns
Dam per
Closure
AHU Shutdown
X X
Activ ate s H orn/Stro be 1 20p pm
X
DISCHARGE PRESSURE SWITCH PNEUMATIC CONNECTION DETAIL
FINISHED FLOOR
FINISHED FLOOR MI
NI
MU
M
DI
ME
NS
IO
N
TO
O
PE
RA
BL
E
PA
RT
HORN/STROBE NOTIFICATION DEVICE NOVEC-1230 RELEASE & ABORT STATION
LENS IN
THIS AREA
80"
96"
42"
TY
PI
CA
L D
IM
EN
SI
ON
TO
O
PE
RA
BL
E
PA
RT
48"
MA
XI
MU
M
DI
ME
NS
IO
N
TO
O
PE
RA
BL
E
PA
RT
54"
INSTALLATION DETAILS
CLEAN AGENT
PUSH
PULL
PIPE SUPPORT DETAIL
3/8"
PIPE SIZE: MAXIMUM SPACING:
5'-0"
1/2" 5'-0"
3/4" 6'-0"
1" 7'-0"
1-1/4" 8'-0"
1-1/2" 9'-0"
2" 11'-0"
2-1/2" 11'-0"
3" 12'-0"
4" 14'-0"
6" 17'-0"
PIPE SUPPORT SPACING CHART
FINISHED FLOOR
STROBE NOTIFICATION DEVICE
LENS IN
THIS AREA
80"
96"
MOUNTING DETAIL (ON CEILING)
SMOKE DETECTOR
DO NOT ENTER
WHEN FLASHING
LEAVE AREA
WHEN ALARM
SOUNDS
CLEAN AGENT FIRE
SUPPRESSION SYSTEM
BEING RELEASED
NOVEC-1230
SYSTEM
ABORT
SIGN SIGN SIGN
BELL:
FIRE SUPPRESSION SYSTEM
FIRST ALARM
HORN/STROBE:
FIRE SUPPRESSION SYSTEM
COUNTDOWN STARTED
BELL
MOUNTING DETAIL (ON WALL)
RELEASE PANEL
70"
FINISHED FLOOR
MODULES
RELEASE PANEL
MOUNTING DETAIL (ON CEILING)
NOZZLE SUPPORT
R E V I S I O N S
VO
LU
SI
A
C O
U N
TY
O
FF
IC
E O
F
TH
E D
IS
TR
IC
T
M
ED
IC
A
L
EX
A M
IN
ER
T
IG
ER
B
AY
R
D
D
AY
TO
N
A
BE
AC
H
, F L
DRAWING NO.:
JOB # 22-F-K0012
DATE 5/9/22
DESIGNER C. REVIS
APPROVED C. REVIS
DRAWING TITLE:
E N G I N E E R S E A L
1 6/27/22 C.R.DATE BY
K N
O X
V
IL
LE
, T
N
JA
C K
SO
N
V
IL
LE
, F
L
TA
M
PA
, F L
O R
LA
N
D O
, F L
B A
LT
IM
O R
E, M
D R
IC
H
M O
N D
, V A
R O
A N
O K
E, V
A C
H
ES
A
PE
A K
E, V
A
C H
A R
LO
TT
E, N
C R
A
LE
IG
H
, N C
C H
A R
LE
ST
O N
, S C
TU
LS
A , O
K
SA
N A
N
TO
N
IO
, T X
D A
LL
A
S, T
X H
O U
ST
O
N , T
X
N A
SH
V
IL
LE
, T N
W A
SH
IN
G
TO
N , D
C
A
TL
A N
TA
, G
A B
IR
M
IN
G
H A
M , A
L
Th is d ra w in g is p ro pe rt y of
F ire a nd
L ife
S af et y
A m er ic a an d is n ot to b e du pl ic at ed a nd
/o r di st rib ut ed w ith ou t w rit te n au th or iz at io n fr om F ire a nd L ife S af et y A m er ic a.
f l s a f ir e a n d l if e s a f e t y a m e r ic a p r o t e c t in g a m e r ic a
Fi le
L oc at io n- C
:\A
SH
P R
O
JE
C
TS
\O R
LA
N
D O
\V ol us ia
C ou nt y
M ed ic al
E xa m in er 's
O ff ic e\
FL
SA
D
ES
IG
N
\V O
LU
SI
A C
O U
N
TY
M
ED
IC
A
L
EX
A M
IN
ER
S O
FF
IC
E
- N
O V
EC
S
U
PP
R
ES
SI
O
N fo r R O
O M
S
R
EV
1.
dw g
Pl ot te d-
/1
9/
:2
PM
B y- C hr is
R ev is [F
L- O
R L]
O ld
L ak e M ar y
R d.
S an fo rd
, F L
7)
-1
(4
) 6
-4 w w w
.fl sa m er ic a.
co m
NFPA STANDARDS:
#101 (2018 EDITION) - Chapter 19
#72 (2016 EDITION)
#70 (2017 EDITION)
#2001 (2018 EDITION)
C R I T E R I A
TYPE SYSTEM:
CLEAN AGENT FIRE SUPPRESSION
CONVENTIONAL or ADDRESSABLE
S Y S T E M D E S I G N
CIRCUITS CLASS A or CLASS B
Florida Building Code (7th Edition 2020)
MANUFACTURERS REQUIREMENTS
Florida Fire Prevention Code (7th Edition)
SYSTEM
CURTIS ENGINEERING SERVICE, LLC
CA#31561
JAMES M. CURTIS, P.E.
PE#37912
27341 SUNNYSIDE DR.
LEESBURG, FL 34748
RELOCATED CYLINDERS PER EOR COMMENT.
WIRING DIAGRAM,
CALCULATIONS &
LOGIC MATRIX
FS6 of 6WIRING RISER DIAGRAM CASE - FILES ROOM 124 or PROPERTY / EVIDENCE ROOM 318
AS-BUILT 12/19/23
AutoCAD SHX Text
TB3
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
LINE
AutoCAD SHX Text 3A
AutoCAD SHX Text 250V
AutoCAD SHX Text
- BLK
AutoCAD SHX Text
LINE
AutoCAD SHX Text
NEUT
AutoCAD SHX Text
RED +
AutoCAD SHX Text
24 VDC
AutoCAD SHX Text
TB1
AutoCAD SHX Text
RAC 1
AutoCAD SHX Text
RAC 2
AutoCAD SHX Text
NAC 2
AutoCAD SHX Text
NAC 1
AutoCAD SHX Text
IDC 1
AutoCAD SHX Text
TB2
AutoCAD SHX Text
IDC 3
AutoCAD SHX Text
IDC 2
AutoCAD SHX Text
IDC 4
AutoCAD SHX Text
SPM 3
AutoCAD SHX Text
SPM 1
AutoCAD SHX Text
24V AUX
AutoCAD SHX Text
ON
AutoCAD SHX Text
RELAY 1
AutoCAD SHX Text
RELAY 3
AutoCAD SHX Text
RELAY 2
AutoCAD SHX Text
RELAY 4
AutoCAD SHX Text
JUMPERS SET TO
AutoCAD SHX Text
NORMALLY OPENED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1/4 BSPP
AutoCAD SHX Text
PNEUMATIC OUTLET
AutoCAD SHX Text
CYL VALVE
AutoCAD SHX Text 570342
AutoCAD SHX Text
1/4 BSPP X 1/4" NPT ADAPTER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1/4" THREADED COUPLING CLASS-300 MI
AutoCAD SHX Text
AutoCAD SHX Text
PART NO
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text 31810
AutoCAD SHX Text
1/4" NPT X 7/16-20 MALE ACTUATION ELBOW
AutoCAD SHX Text
AutoCAD SHX Text 32336
AutoCAD SHX Text
1/4" ACTUATION HOSE 7/16-20 SWIVELS
AutoCAD SHX Text
AutoCAD SHX Text 32338
AutoCAD SHX Text
7/16-20 X 1/4" NPT MALE STRAIGHT ADAPTOR
AutoCAD SHX Text
AutoCAD SHX Text
DISCHARGE PRESSURE SWITCH
AutoCAD SHX Text
W/ 1/4" FNPT INLET
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
MOUNTED TO
AutoCAD SHX Text
SURFACE MOUNT
AutoCAD SHX Text
BACK BOX
AutoCAD SHX Text
UNISTRUT
AutoCAD SHX Text
PIPE CLAMP
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
ANCHORED TO
AutoCAD SHX Text
WALL
AutoCAD SHX Text Steel
AutoCAD SHX Text (Length)
AutoCAD SHX Text A.T.Rod
AutoCAD SHX Text Hanger Ring
AutoCAD SHX Text Beam Clamp
AutoCAD SHX Text
UL <> FM
AutoCAD SHX Text
DROP-IN
AutoCAD SHX Text
UL <> FM
AutoCAD SHX Text Hanger Ring
AutoCAD SHX Text A.T.Rod
AutoCAD SHX Text (Length)
AutoCAD SHX Text
NTS
AutoCAD SHX Text
ABORT
AutoCAD SHX Text
RELEASE
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
6" BASE
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
OR OCT BOX
AutoCAD SHX Text
4" SQUARE BOX
AutoCAD SHX Text
DECK
AutoCAD SHX Text
3/8 X 1/4 BUSHING
AutoCAD SHX Text
PROVIDED WITH PRESSURE SWITCH
AutoCAD SHX Text
NTS
AutoCAD SHX Text
UNISTRUT
AutoCAD SHX Text
PIPE CLAMP
AutoCAD SHX Text
ANCHORED TO
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NOZZLE
| Sheets and Views |
| VOLUSIA COUNTY MEDICAL EXAMINERS OFFICE - NOVEC SUPPRESSION for ROOMS 124 & 318 - REV1-FS1 |
| VOLUSIA COUNTY MEDICAL EXAMINERS OFFICE - NOVEC SUPPRESSION for ROOMS 124 & 318 - REV1-FS2 |
| VOLUSIA COUNTY MEDICAL EXAMINERS OFFICE - NOVEC SUPPRESSION for ROOMS 124 & 318 - REV1-FS3 |
| VOLUSIA COUNTY MEDICAL EXAMINERS OFFICE - NOVEC SUPPRESSION for ROOMS 124 & 318 - REV1-FS4 |
| VOLUSIA COUNTY MEDICAL EXAMINERS OFFICE - NOVEC SUPPRESSION for ROOMS 124 & 318 - REV1-FS5 |
| VOLUSIA COUNTY MEDICAL EXAMINERS OFFICE - NOVEC SUPPRESSION for ROOMS 124 & 318 - REV1-FS6 |
File details come from the government source that posted it. Updated .