VA Medical Ctr Bldg 3 2204284 IH Survey Report_PDF FINAL 04 19 2022 0934.pdf

PDF 628 KB Posted

Attached to
36C25623R0012 - 520-22-178-Z1DZ--CON Correct FCA Deficiencies related to Project No. 520-22-178
Solicitation number
36C25622R0012
Issued by

About this file

This report summarizes the results of an industrial hygiene survey conducted at the VA Medical Center in Biloxi, Mississippi. The survey inspected painted components in several rooms in Building 3 for the presence of lead-based paint using an X-ray fluorescence analyzer. No lead-based paint was detected on any of the interior surfaces tested, which were reported to be in good condition. The second document is a solicitation seeking offers for a project to correct deficiencies related to lead-based paint remediation work at the same VA Medical Center. This 100% set-aside opportunity for Veteran Owned Small Businesses is issued by the Department of Veterans Affairs Veterans Health Administration VISN 16 and has an opportunity number of 36C25622R0012.

View the file

Other files

File Type Posted
36C25623R0012 RFI Responses R1.docx DOCX document
Wall Guard Specs.pdf PDF
BL T-102 flooring common areas.pdf PDF
T-105.pdf PDF
Starc Catalog.pdf PDF
Canopy 3.pdf PDF
Access Drive for Rollup Door.pdf PDF
REVISED SOW 520-22-178 Correct FCA Deficiencies Multiple Bldgs 11.23.22.docx DOCX document
36C25623R0012 0001.pdf PDF
Canopy 1.pdf PDF
T-104 Rm 101-103-104-104A-104B-104C-C113-C111.pdf PDF
Canopy 2.pdf PDF
T-102 Renovations Floor Covering 4-12-22.pdf PDF
SOW 520-22-178 Correct FCA Deficiencies Multiple Bldgs R1.docx DOCX document
bldg 3 various room elevations and details- Laundry_Garbage Chutes.pdf PDF
36C25623R0012 EXHIBIT B.docx DOCX document
42 - 3-4 - Ground Floor Plan Area 2.pdf PDF
Exhibit 15 Walkways For Dock Access.pdf PDF
Brand Name JA-FCA-22-178_Signed 1_Redacted.pdf PDF
36C25623R0012 EXHIBIT C.docx DOCX document
Specs_05_16.pdf PDF
31 ACCESS DRIVE.pdf PDF
B30 - Dock LVT 8-22-22.pdf PDF
51 - 3-13 - Third Floor Plan Area 2.pdf PDF
T-105 ArchDiagram.pdf PDF
Exhibit 3 Chutes-VA HOSPITAL_Redacted.pdf PDF
T102 Floor Framing Layout.pdf PDF
ICRA Contracting Only.pdf PDF
36C25623R0012 EXHIBIT A.docx DOCX document
48 - 3-10 - Second Floor Plan Area 2.pdf PDF
VHA Supplemental Contract Requirements for Ensuring Adequate COVID-19 Safety Protocols for Federal Contractors.pdf PDF
T-102 Fire Spklr Shop Drawing.pdf PDF
36C25623R0012 EXHIBIT D.docx DOCX document
T-102 STARC Systems.pdf PDF
Handrails Details.pdf PDF
36C25623R0012 EXHIBIT E.docx DOCX document
T-102-FLOORING Issues_Updated.pdf PDF
96 - 3-58 - Toilet Room and Shower Elevations Soiled Linen and Trash Rooms.pdf PDF
WD MS20220050 Mod 3 dtd 10-7-2022.pdf PDF
36C25623R0012 Solicitation.pdf PDF
T-104 ArchDiagram.pdf PDF
30a - Wall Paint Details.pdf PDF
T-102 Blocking and TieDown Details.pdf PDF
Exhibit 30 - Automatic Scan Door Opener.pdf PDF
36C25623R0012 EXHIBIT F.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6500 Sunplex Drive

Ocean Springs, MS 39564

228.875.6420 Phone

228.875.6423 Fax

Mailing Address:

PO Box 1410

Ocean Springs, MS

39566-1410

LELAP Certification # 01960Lab ID# MS00021 TNI ID # TNI01397

VA Medical Center

RE: Building 3 Trash & Laundry Chute Rooms

Biloxi, MS 39531

400 Veterans Blvd.

Misty Madison

Enclosed are the results of survey performed by the industrial hygiene department on 4/13/2022. If you have any questions concerning this report, please feel free to contact me.

Sincerely, April 19, 2022

Mitch Spicer

Lab Director

Work Order # : 2204284

Purchase Order # Q22346

DISCLAIMER

This report shall not be reproduced except in full, without the approval of Micro-Methods Laboratory, Inc.

Project:

Project Number:

Project Manager:

Reported:

6500 Sunplex Drive

Ocean Springs, MS 39564

228-875-6420 Phone

228-875-6423 Fax

Field Report

Summary Comments:

On 04/13/2022 Charles D. Bingham, Representative of Micro-Methods Laboratory, Inc. performed a limited lead-based paint (LBP) inspection of painted components in rooms 2D 102, 2D 106, 2D 105, 3D 106, 3D 107, 4D 106, and 4D 107 of building 3 at the VA Medical Center, Biloxi, Mississippi at the request of Misty Madison with the

Safety Department. The lead-based paint inspection was conducted using a Niton

X-Ray Fluorescence machine (XRF) to determine the presence of lead-based paint on surfaces. The XRF allowed the inspectors to thoroughly test painted surfaces without damage to the surface or substrate throughout the structure in accordance with HUD

Guidelines for the Evaluation and Control of Lead Based Paint Hazards in Housing, Chapter 7, Lead Base Paint Inspections and the State of Mississippi Regulations for

Lead-Based Paint Activities, Miss. Code Annotated Sections 49-17-501 through

49-17-531.

The following is a summary of the findings.

Items sampled included interior components (see spreadsheet).

All building components sampled had XRF readings less than the HUD action level of

1.0 mg/cm² at the time of this inspection (see attached XRF results).

Lead-based paint was not identified during this inspection. All interior surfaces tested were in good condition.

Inspector: Charles D. Bingham

MSDEQ Cert. #PBI-3690

Exp. 01/29/2023

The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.

Project:

Project Number:

Project Manager:

Reported:

6500 Sunplex Drive

Ocean Springs, MS 39564

228-875-6420 Phone

228-875-6423 Fax

Laboratory Accreditations/Certifications

Code Description Number Expires

01960LA Environmental Lab Accreditation Program 06/30/2022C01

TNI01397The NELAC Institute (NELAP) 06/30/2022C02

MS00021Ms Dept of Health (Drinking Water Microbiology) 12/31/2022C03

MS00021Ms Dept of Health (Drinking Water Chemistry) 12/31/2022C04

PBF-00000028Ms DEQ Lead Firm Certification 03/24/2023C05

ABI-00001348MsDEQ Asbestos Inspector : C.D. Bingham 02/12/2023C06

AM-011572MsDEQ Air Monitor : C.D. Bingham 02/13/2023C07

ABI-00001821MsDEQ Asbestos Inspector: C. W. Meins 09/09/2022C08

AM-011189MsDEQ Air Monitor : C.W. Meins 02/13/2023C09

PBI-00003690MsDEQ Lead Paint Inspector : C.D. Bingham 01/29/2023C14

PBI-00001740MsDEQ Lead Paint Inspector : C.W. Meins 01/29/2023C15

The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.

Site Address:

VA Medical Center Building #3

Trash Laundry Chute Rooms

Biloxi, MS

X-Ray Fluorescence

Lead-Based Paint Inspection

Date: 04/13/2022

VA Medical Center

WO#2204284

Instrument: Niton XLp 300A

Ser.# 12601

Inspection Firm: Micro-Methods Laboratory, Inc.

6500 Sunplex Dr. Ocean Springs, MS 39564

Inspector: Charles D. Bingham

MSDEQ Cert. #PBI3690

Exp. 01-29-2023

Sample Location Component Substrate Color Side Action Pb Results

Level mg/cm²

1 1 Good

1 0.9 Good

1 0.9 Good

2D 102 Wall Tile Tan A 1 <1 Negative

2D 102 Wall Tile Tan B 1 <1 Negative

2D 102 Wall Tile Tan C 1 <1 Negative

2D 102 Wall Tile Tan D 1 <1 Negative

2D 102 Ceiling Composite White 1 <1 Negative

2D 102 Door Metal White A 1 <1 Negative

2D 102 Door Casing Metal White A 1 <1 Negative

2D 106 Wall Tile Tan A 1 <1 Negative

2D 106 Wall Tile Tan B 1 <1 Negative

2D 106 Wall Tile Tan C 1 <1 Negative

2D 106 Wall Tile Tan D 1 <1 Negative

2D 106 Ceiling Composite White 1 <1 Negative

2D 106 Door Wood Varnish A 1 <1 Negative

2D 106 Door Casing Metal White A 1 <1 Negative

2D 105 Wall Tile Tan A 1 <1 Negative

2D 105 Wall Tile Tan B 1 <1 Negative

2D 105 Wall Tile Tan C 1 <1 Negative

2D 105 Wall Tile Tan D 1 <1 Negative

2D 105 Ceiling Composite White 1 <1 Negative

2D 105 Door Wood Varnish A 1 <1 Negative

2D 105 Door Casing Metal White A 1 <1 Negative

3D 106 Wall Tile Tan A 1 <1 Negative

3D 106 Wall Tile Tan B 1 <1 Negative

3D 106 Wall Tile Tan C 1 <1 Negative

3D 106 Wall Tile Tan D 1 <1 Negative

3D 106 Ceiling Composite White 1 <1 Negative

3D 106 Door Metal White A 1 <1 Negative

3D 106 Door Casing Metal White A 1 <1 Negative

3D 107 Wall Tile Tan A 1 <1 Negative

3D 107 Wall Tile Tan B 1 <1 Negative

3D 107 Wall Tile Tan C 1 <1 Negative

3D 107 Wall Tile Tan D 1 <1 Negative

3D 107 Ceiling Composite White 1 <1 Negative

3D 107 Door Metal White A 1 <1 Negative

3D 107 Door Casing Metal White A 1 <1 Negative

1.0 mg/cm² Calibration Standard

Site Address:

VA Medical Center Building #3

Trash Laundry Chute Rooms

Biloxi, MS

X-Ray Fluorescence

Lead-Based Paint Inspection

Date: 04/13/2022

VA Medical Center

WO#2204284

Instrument: Niton XLp 300A

Ser.# 12601

Inspection Firm: Micro-Methods Laboratory, Inc.

6500 Sunplex Dr. Ocean Springs, MS 39564

Inspector: Charles D. Bingham

MSDEQ Cert. #PBI3690

Exp. 01-29-2023

Sample Location Component Substrate Color Side Action Pb Results

Level mg/cm²

4D 106 Wall Plaster Gray A 1 <1 Negative

4D 106 Wall Plaster Gray B 1 <1 Negative

4D 106 Wall Plaster Gray C 1 <1 Negative

4D 106 Wall Plaster Gray D 1 <1 Negative

4D 106 Ceiling Composite White 1 <1 Negative

4D 106 Door Wood Varnish A 1 <1 Negative

4D 106 Door Casing Metal White A 1 <1 Negative

4D 107 Wall Tile Gray A 1 <1 Negative

4D 107 Wall Tile Gray B 1 <1 Negative

4D 107 Wall Tile Gray C 1 <1 Negative

4D 107 Wall Tile Gray D 1 <1 Negative

4D 107 Ceiling Composite White 1 <1 Negative

4D 107 Door Metal White A 1 <1 Negative

4D 107 Door Casing Metal White A 1 <1 Negative

1 1.1 Good

1 1 Good

1 1 Good

1.0 mg/cm² Calibration Standard

File details come from the government source that posted it. Updated .