This report summarizes the results of an industrial hygiene survey conducted at the VA Medical Center in Biloxi, Mississippi. The survey inspected painted components in several rooms in Building 3 for the presence of lead-based paint using an X-ray fluorescence analyzer. No lead-based paint was detected on any of the interior surfaces tested, which were reported to be in good condition. The second document is a solicitation seeking offers for a project to correct deficiencies related to lead-based paint remediation work at the same VA Medical Center. This 100% set-aside opportunity for Veteran Owned Small Businesses is issued by the Department of Veterans Affairs Veterans Health Administration VISN 16 and has an opportunity number of 36C25622R0012.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6500 Sunplex Drive
Ocean Springs, MS 39564
228.875.6420 Phone
228.875.6423 Fax
Mailing Address:
PO Box 1410
Ocean Springs, MS
39566-1410
LELAP Certification # 01960Lab ID# MS00021 TNI ID # TNI01397
VA Medical Center
RE: Building 3 Trash & Laundry Chute Rooms
Biloxi, MS 39531
400 Veterans Blvd.
Misty Madison
Enclosed are the results of survey performed by the industrial hygiene department on 4/13/2022. If you have any questions concerning this report, please feel free to contact me.
Sincerely, April 19, 2022
Mitch Spicer
Lab Director
Work Order # : 2204284
Purchase Order # Q22346
DISCLAIMER
This report shall not be reproduced except in full, without the approval of Micro-Methods Laboratory, Inc.
Project:
Project Number:
Project Manager:
Reported:
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
Field Report
Summary Comments:
On 04/13/2022 Charles D. Bingham, Representative of Micro-Methods Laboratory, Inc. performed a limited lead-based paint (LBP) inspection of painted components in rooms 2D 102, 2D 106, 2D 105, 3D 106, 3D 107, 4D 106, and 4D 107 of building 3 at the VA Medical Center, Biloxi, Mississippi at the request of Misty Madison with the
Safety Department. The lead-based paint inspection was conducted using a Niton
X-Ray Fluorescence machine (XRF) to determine the presence of lead-based paint on surfaces. The XRF allowed the inspectors to thoroughly test painted surfaces without damage to the surface or substrate throughout the structure in accordance with HUD
Guidelines for the Evaluation and Control of Lead Based Paint Hazards in Housing, Chapter 7, Lead Base Paint Inspections and the State of Mississippi Regulations for
Lead-Based Paint Activities, Miss. Code Annotated Sections 49-17-501 through
49-17-531.
The following is a summary of the findings.
Items sampled included interior components (see spreadsheet).
All building components sampled had XRF readings less than the HUD action level of
1.0 mg/cm² at the time of this inspection (see attached XRF results).
Lead-based paint was not identified during this inspection. All interior surfaces tested were in good condition.
Inspector: Charles D. Bingham
MSDEQ Cert. #PBI-3690
Exp. 01/29/2023
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.
Project:
Project Number:
Project Manager:
Reported:
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
Laboratory Accreditations/Certifications
Code Description Number Expires
01960LA Environmental Lab Accreditation Program 06/30/2022C01
TNI01397The NELAC Institute (NELAP) 06/30/2022C02
MS00021Ms Dept of Health (Drinking Water Microbiology) 12/31/2022C03
MS00021Ms Dept of Health (Drinking Water Chemistry) 12/31/2022C04
PBF-00000028Ms DEQ Lead Firm Certification 03/24/2023C05
ABI-00001348MsDEQ Asbestos Inspector : C.D. Bingham 02/12/2023C06
AM-011572MsDEQ Air Monitor : C.D. Bingham 02/13/2023C07
ABI-00001821MsDEQ Asbestos Inspector: C. W. Meins 09/09/2022C08
AM-011189MsDEQ Air Monitor : C.W. Meins 02/13/2023C09
PBI-00003690MsDEQ Lead Paint Inspector : C.D. Bingham 01/29/2023C14
PBI-00001740MsDEQ Lead Paint Inspector : C.W. Meins 01/29/2023C15
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.
Site Address:
VA Medical Center Building #3
Trash Laundry Chute Rooms
Biloxi, MS
X-Ray Fluorescence
Lead-Based Paint Inspection
Date: 04/13/2022
VA Medical Center
WO#2204284
Instrument: Niton XLp 300A
Ser.# 12601
Inspection Firm: Micro-Methods Laboratory, Inc.
6500 Sunplex Dr. Ocean Springs, MS 39564
Inspector: Charles D. Bingham
MSDEQ Cert. #PBI3690
Exp. 01-29-2023
Sample Location Component Substrate Color Side Action Pb Results
Level mg/cm²
1 1 Good
1 0.9 Good
1 0.9 Good
2D 102 Wall Tile Tan A 1 <1 Negative
2D 102 Wall Tile Tan B 1 <1 Negative
2D 102 Wall Tile Tan C 1 <1 Negative
2D 102 Wall Tile Tan D 1 <1 Negative
2D 102 Ceiling Composite White 1 <1 Negative
2D 102 Door Metal White A 1 <1 Negative
2D 102 Door Casing Metal White A 1 <1 Negative
2D 106 Wall Tile Tan A 1 <1 Negative
2D 106 Wall Tile Tan B 1 <1 Negative
2D 106 Wall Tile Tan C 1 <1 Negative
2D 106 Wall Tile Tan D 1 <1 Negative
2D 106 Ceiling Composite White 1 <1 Negative
2D 106 Door Wood Varnish A 1 <1 Negative
2D 106 Door Casing Metal White A 1 <1 Negative
2D 105 Wall Tile Tan A 1 <1 Negative
2D 105 Wall Tile Tan B 1 <1 Negative
2D 105 Wall Tile Tan C 1 <1 Negative
2D 105 Wall Tile Tan D 1 <1 Negative
2D 105 Ceiling Composite White 1 <1 Negative
2D 105 Door Wood Varnish A 1 <1 Negative
2D 105 Door Casing Metal White A 1 <1 Negative
3D 106 Wall Tile Tan A 1 <1 Negative
3D 106 Wall Tile Tan B 1 <1 Negative
3D 106 Wall Tile Tan C 1 <1 Negative
3D 106 Wall Tile Tan D 1 <1 Negative
3D 106 Ceiling Composite White 1 <1 Negative
3D 106 Door Metal White A 1 <1 Negative
3D 106 Door Casing Metal White A 1 <1 Negative
3D 107 Wall Tile Tan A 1 <1 Negative
3D 107 Wall Tile Tan B 1 <1 Negative
3D 107 Wall Tile Tan C 1 <1 Negative
3D 107 Wall Tile Tan D 1 <1 Negative
3D 107 Ceiling Composite White 1 <1 Negative
3D 107 Door Metal White A 1 <1 Negative
3D 107 Door Casing Metal White A 1 <1 Negative
1.0 mg/cm² Calibration Standard
Site Address:
VA Medical Center Building #3
Trash Laundry Chute Rooms
Biloxi, MS
X-Ray Fluorescence
Lead-Based Paint Inspection
Date: 04/13/2022
VA Medical Center
WO#2204284
Instrument: Niton XLp 300A
Ser.# 12601
Inspection Firm: Micro-Methods Laboratory, Inc.
6500 Sunplex Dr. Ocean Springs, MS 39564
Inspector: Charles D. Bingham
MSDEQ Cert. #PBI3690
Exp. 01-29-2023
Sample Location Component Substrate Color Side Action Pb Results
Level mg/cm²
4D 106 Wall Plaster Gray A 1 <1 Negative
4D 106 Wall Plaster Gray B 1 <1 Negative
4D 106 Wall Plaster Gray C 1 <1 Negative
4D 106 Wall Plaster Gray D 1 <1 Negative
4D 106 Ceiling Composite White 1 <1 Negative
4D 106 Door Wood Varnish A 1 <1 Negative
4D 106 Door Casing Metal White A 1 <1 Negative
4D 107 Wall Tile Gray A 1 <1 Negative
4D 107 Wall Tile Gray B 1 <1 Negative
4D 107 Wall Tile Gray C 1 <1 Negative
4D 107 Wall Tile Gray D 1 <1 Negative
4D 107 Ceiling Composite White 1 <1 Negative
4D 107 Door Metal White A 1 <1 Negative
4D 107 Door Casing Metal White A 1 <1 Negative
1 1.1 Good
1 1 Good
1 1 Good
1.0 mg/cm² Calibration Standard