This document contains specifications for trash and linen chutes to be installed at a VA hospital in Mississippi, as well as information on a related federal contract opportunity. The specifications indicate that one trash chute and one linen chute will be provided according to NFPA82 Edition 2014 standards. Each chute will be 24 inches in diameter with 16 gauge aluminized steel construction. Intake doors will be made of stainless steel and located on the second through fourth floors. Additional included features are lever handles, sound insulation coating, isolation pads, accordion discharge doors, sanitizing units, vent caps and flashing. Floor supports, a wash-down spray head and sprinkler system are also specified. The related federal contract opportunity is a re-solicitation under number 36C25623R0012 for project 520-22-178 to correct deficiencies at the facility. This is a 100% set-aside for Veteran Owned Small Businesses.

View the file

Other files

File Type Posted
36C25623R0012 RFI Responses R1.docx DOCX document
Wall Guard Specs.pdf PDF
BL T-102 flooring common areas.pdf PDF
T-105.pdf PDF
Starc Catalog.pdf PDF
Canopy 3.pdf PDF
Access Drive for Rollup Door.pdf PDF
REVISED SOW 520-22-178 Correct FCA Deficiencies Multiple Bldgs 11.23.22.docx DOCX document
36C25623R0012 0001.pdf PDF
Canopy 1.pdf PDF
T-104 Rm 101-103-104-104A-104B-104C-C113-C111.pdf PDF
Canopy 2.pdf PDF
T-102 Renovations Floor Covering 4-12-22.pdf PDF
SOW 520-22-178 Correct FCA Deficiencies Multiple Bldgs R1.docx DOCX document
bldg 3 various room elevations and details- Laundry_Garbage Chutes.pdf PDF
36C25623R0012 EXHIBIT B.docx DOCX document
42 - 3-4 - Ground Floor Plan Area 2.pdf PDF
Exhibit 15 Walkways For Dock Access.pdf PDF
Brand Name JA-FCA-22-178_Signed 1_Redacted.pdf PDF
36C25623R0012 EXHIBIT C.docx DOCX document
Specs_05_16.pdf PDF
31 ACCESS DRIVE.pdf PDF
B30 - Dock LVT 8-22-22.pdf PDF
51 - 3-13 - Third Floor Plan Area 2.pdf PDF
T-105 ArchDiagram.pdf PDF
T102 Floor Framing Layout.pdf PDF
ICRA Contracting Only.pdf PDF
36C25623R0012 EXHIBIT A.docx DOCX document
48 - 3-10 - Second Floor Plan Area 2.pdf PDF
VHA Supplemental Contract Requirements for Ensuring Adequate COVID-19 Safety Protocols for Federal Contractors.pdf PDF
T-102 Fire Spklr Shop Drawing.pdf PDF
36C25623R0012 EXHIBIT D.docx DOCX document
T-102 STARC Systems.pdf PDF
VA Medical Ctr Bldg 3 2204284 IH Survey Report_PDF FINAL 04 19 2022 0934.pdf PDF
Handrails Details.pdf PDF
36C25623R0012 EXHIBIT E.docx DOCX document
T-102-FLOORING Issues_Updated.pdf PDF
96 - 3-58 - Toilet Room and Shower Elevations Soiled Linen and Trash Rooms.pdf PDF
WD MS20220050 Mod 3 dtd 10-7-2022.pdf PDF
36C25623R0012 Solicitation.pdf PDF
T-104 ArchDiagram.pdf PDF
30a - Wall Paint Details.pdf PDF
T-102 Blocking and TieDown Details.pdf PDF
Exhibit 30 - Automatic Scan Door Opener.pdf PDF
36C25623R0012 EXHIBIT F.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

600 Twin Rail Drive Phone: (815)723-7632 Minooka, IL 60447 Fax: (815)723-7652

VA Gulf Coast Veterans Health Care System 400 Veterans Avenue Biloxi, Mississippi 39531

RE: VA Hospital - Mississippi

ONE (1) TRASH CHUTE per NFPA82 Edition 2014, EACH to be equipped as follows:

24” diameter 16 gauge aluminized steel Three (3) U.L. ‘B’ label 15” x 18” bottom hinged, hand operated, stainless steel intake doors

250° maximum door temperature rise over 30 minutes, 1-1/2 hour assembly – doors located at 2nd-4th floors

Lever handles Factory applied Daubert V-Damp ‘3680’ soundcoat Korfund type isolator pads Accordion style discharge door Sanitizing unit with 15”x15” access door Full diameter vent cap, body, and flashing

ONE (1) LINEN CHUTE per NFPA82 Edition 2014, EACH to be equipped as follows:

24” diameter 16 gauge aluminized steel Three (3) U.L. ‘B’ label 21” x 21” side hinged, hand operated, stainless steel intake doors

250° maximum door temperature rise over 30 minutes, 1-1/2 hour assembly – doors located at 2nd-4th floors

Lever handles Factory applied Daubert V-Damp ‘3680’ soundcoat Korfund type isolator pads Accordion style discharge door Sanitizing unit with 15”x15” access door Full diameter vent cap, body, and flashing

In addition to the above material, American Chute LLC has included all necessary 1-1/2” X 1-1/2” X 1/8 floor supports, a wash-down spray head, and a sprinkler head above the top intake, with additional sprinkler heads at alternate floors. Throat dimensions of the chute radius plus 10” assumed unless otherwise stated. Sprinkler heads are ‘snug fit’ installed in the coupling above the appropriate intake doors. Final connection (tightening, pressure testing, leak detection, etc) is the responsibility of others,