This document contains an exhibit detailing scope of work improvements for an automatic scan door opener project at a Veterans Affairs facility, along with a related federal contract opportunity solicitation. The scope of work involves adding a card reader and automatic door opener actuator, push button door opener, wall bumpers, replacing doors and hardware to include auto openers connected to the card reader and push button. Additional work includes adding wall protection, repairing and painting walls, replacing damaged light fixtures, ceiling tiles, flooring, and thresholds. The related solicitation is for corrective action to address deficiencies on Project 520-22-178, which is 100% set aside for Veteran Owned Small Businesses. The solicitation does not include pricing terms but provides the project number, a description of deficiencies to be addressed, and identifies the contracting agency as the Department of Veterans Affairs Veterans Health Administration VISN 16.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OI&T
ENG
1H-147
1H-151
1H-149
C1-41
OFFICE
DATA / TELE
ELEC CLOSET
RECEIVING
1H100
Room 1A172
Scope of Work
1. ADD CARD READER w/ AUTO DOOR OPEN
ACTUATOR.
2. ADD PUSH BUTTON DOOR OPENER
3. ADD WALL BUMPERS TO MATCH EXISTING ON
ON WALLS WHERE NOT PRESENT - MATCH HEIGHT
OF EXISTING.
4. REMOVE AND REPLACE EXISTING DOORS,
FRAMES, HARDWARE AND ACCESSORIES WITH
LIKE IN TYPE AND SIZE. ADD AUTO OPENER
CONNECTED TO CARD READER AND PUSH
BUTTON.
5. ADD WALL PROTECTION ALL WALLS. 4x8 SHEETS
PLACED HORIZONTAL W/ PAINT ABOVE.
INPRO: ANTIQUE WHITE 0104. CUT TO FIT WHERE
REQUIRED.
6. REPAIR PREP AND PAINT ALL WALLS. MATCH
EXISTING. NAVAJO WHITE SW6126.
7. REPLACE ANY DAMAGED LIGHT FIXTURES AND
CEILING TILES/TRACK WITH NEW.
8. REPLACE DAMAGED LVT SQUARE WITH
MATCHING. COLORMATCH T.B.D.
9. INCREASE DOOR UNDERCUT AS NEEDED TO
PREVENT FUTURE FLOOR DAMAGE. (EXISTING
FLOOR IS UNLEVEL THIS AREA).
10. NEW THRESHOLD SHALL BE LOW-PROFILE
THRESHOLD. ADD HEAVY DUTY (HIGH-USE) DOOR
SWEEPS AS NEEDED TO ENSURE SECURE
EXTERIOR BUILDING ENVELOPE.
NOTE:
CHECK ALL EXISTING ELECTRICAL. TO BE CLEANED AND
REUSED AS ABLE. REPLACE ANY DAMAGED OR
DEFECTIVE WITH NEW TO MATCH EXISTING.
Offic e of Fac ilit ies
A
Drawing Prepared By:
SPACE COMMITTEE
CAPITAL ASSET MANAGEMENT COMMITTEE
Building / Location Information: Drawing Title:
Building Number:
Campus:
Address:
Floor # (If Applicable):
Room # / Suite Description:
Sheet Number
Additional Drawing Information:
SHEET OF
B
C
D
E
F
A
B
C
D
E
F
2 3 4 5 6 7 8 9 10
Approved By:
ENGINEERING - ACTIVATIONS OFFICE
Drawing Date:
1H100 Biloxi 400 Veterans Ave, Building 3, Biloxi, MS 39531
IMPROVEMENTS TO LOGISTICS RECEIVING ROOM
BUILDING 30 - LOADING DOCK
3/28/2022
1 1
1/4" = 1'-0"1 BUILDING 30 RECEIVING IMPROVEMENTS