This document provides details on a federal contract opportunity for construction services. The solicitation number is 36c10f21r0018 for the Y1PC--Miramar National Cemetery Phase 2 Construction project. The opportunity type is a solicitation issued by the Department of Veterans Affairs Office of Construction and Facilities Management. The description provided indicates this opportunity is for phase two construction services at the Miramar National Cemetery. No further details on required construction products or services, response dates, or other salient information are included in this document.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B1 B2
REF.
CANOPY ABOVE
CANOPY ABOVE
ELECTRICAL PANEL
MECH
B106
RESTROOM
B105
RESTROOM
B104
JANITOR
B103
LOCKERS
B102
BREAK
ROOM
B101
BA
BB
STORAGE
B107
SOLID SURFACE
WINDOW SILL, TYP.
STORAGE
B108
CR
CR
FEC, SEE
WALK-OFF MAT
(MAT-1)
ELECTRICAL DIMMER
FOR SOLATUBE
PROVIDE 3/4-IN
PLYWOOD
BACKBOARD, PAINT
SB
1 1/2"
DOM. CW UP
1 1/2"
3"
4"
3"
4"
3"
2"
4"
3"
4" UP TO
WCO
P
P
(TYP.)
3"
2" 2"
3"
B1 B2
REF.
CANOPY ABOVE
CANOPY ABOVE
ELECTRICAL PANEL
MECH
B106
RESTROOM
B105
RESTROOM
B104
JANITOR
B103
LOCKERS
B102
BREAK
ROOM
B101
BA
BB
STORAGE
B107
SOLID SURFACE
WINDOW SILL, TYP.
STORAGE
B108
CR
CR
FEC, SEE
WALK-OFF MAT
(MAT-1)
ELECTRICAL DIMMER
FOR SOLATUBE
PROVIDE 3/4-IN
PLYWOOD
BACKBOARD, PAINT
SB
1 1/2"
DOM. CW
DN.
4" VENT
THRU ROOF
2"2" 3"3"
1 1/2"
4"
1"
1 1/2"
3/4"
2"
1/2"
1 1/2"
3/4"
3/4" 3/4"
1/2"
1/2"
3/4"
1/2" 1/2"
1 1/2"
1 1/2" 2"
1/2" 1/2"
P
P
1. PROVIDE 1/2" DOMESTIC COLD WATER LINE AND SHUTOFF VALVE TO COFFEE MAKER.
2. ROUTE T & P LINE FROM WATER HEATER TO FLOOR DRAIN AND TERMINATE AT AN
APPROVED DISTANCE ABOVE THE DRAIN.
3. PROVIDE 1/2" DOMESTIC COLD WATER LINE AND SHUTOFF VALVE TO REFRIGERATOR
ICE MAKER.
4. ROUTE 3/4" CONDENSATE LINE DOWN IN WALL AND TERMINATE AT MOP SINK AT AN
APPROVED DISTANCE PER THE GOVERNING PLUMBING CODE. SIZE AS NOTED ON
DRAWINGS.
5. PROVIDE TRAP GUARDS TO ALL FLOOR DRAINS.
6. PROVIDE DOUBLE CHECK BACKFLOW PREVENTER (WATTS MODEL 007-QT OF
APPROVED EQUAL.
7. SEE CIVIL PLANS FOR CONTINUATION OF DOMESTIC WATER LINE TO WATER MAIN.
8. SEE CIVIL PLANS FOR CONTINUATION OF SANITARY SEWER LINE TO SEWER MAIN.
AB-P-101
HONOR GUARD BUILDING
PLUMBING FLOOR PLAN
JKH KHK
1/8" = 1'-0"1 HONOR GUARD BLDG. - FLOOR PLAN - PLUMBING UNDERFLOOR 1/8" = 1'-0"1 HONOR GUARD BLDG. - FLOOR PLAN - PLUMBING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
A/E OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
February 22, 2021Revisions: Date:
N/A
BID DOCUMENT
ofDwg.
John Gallup & Associates, LLC 3225 Shallowford Rd NE Suite 830 Marietta, GA 30062 770-321-4040
CONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANT
Miramar National Cemetery 5795 Nobel Drive, San Diego, CA 92122
892PC2037.23
PHASE 2 DEVELOPMENT
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1
DI S AB LE D V E T E R AN + E M P LOY E E OW N E D
www.davyarchitecture.com 209 243
AutoCAD SHX Text
AutoCAD SHX Text
DCO
AutoCAD SHX Text
AutoCAD SHX Text
SS
AutoCAD SHX Text
GCO
AutoCAD SHX Text
SS
AutoCAD SHX Text P-413
AutoCAD SHX Text P-413
AutoCAD SHX Text P-101
AutoCAD SHX Text P-101
AutoCAD SHX Text P-502
AutoCAD SHX Text P-528
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
3"FD-1FD-1
AutoCAD SHX Text
3"FD-1FD-1
AutoCAD SHX Text
WH-2
AutoCAD SHX Text
3"FD-1FD-1
AutoCAD SHX Text P-811
AutoCAD SHX Text
WB-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ET-1
AutoCAD SHX Text
AutoCAD SHX Text
DCBFP-1
AutoCAD SHX Text
AutoCAD SHX Text P-202
AutoCAD SHX Text P-202
AutoCAD SHX Text
%%UNOTES BY SYMBOL:
SLOPE
1/4":12"
SLOPE
1/4":12"
SLOPE
1/4":12" (TYP.)
C1 C2 C3 C4
BAY 1
BAY 2
BAY 3
PARTS &
TOOLS
692 SF
AIR
COMPRESSOR
ROOM
61 SF
ELECT
78 SF
CA
CB
CC
A
1 EXISTING COMPRESSED AIR LINE. COORDINATE WITH NEW WALL FOR PENETRATION.
2 EXISTING AIR COMPRESSOR.
AC-P-101
WAREHOUSE BUILDING
PLUMBING FLOOR PLAN
JKH KHK
1/8" = 1'-0"1 WAREHOUSE BLDG. - FLOOR PLAN - PLUMBING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
A/E OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
February 22, 2021Revisions: Date:
N/A
BID DOCUMENT
ofDwg.
John Gallup & Associates, LLC 3225 Shallowford Rd NE Suite 830 Marietta, GA 30062 770-321-4040
CONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANT
Miramar National Cemetery 5795 Nobel Drive, San Diego, CA 92122
892PC2037.23
PHASE 2 DEVELOPMENT
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1
DI S AB LE D V E T E R AN + E M P LOY E E OW N E D
www.davyarchitecture.com 210 243
AutoCAD SHX Text
AutoCAD SHX Text
MAINTENANCE
COMPLEX
STAFF BUILDING
MAINTENANCE COMPLEX
COM
E
MAINTENANCE
COMPLEX
STAFF BUILDINNG
13,112 GSF
(E) MAINTENANCE YARD
(E) FUEL STATION
NEW ASPHALT PAVING
1"
1"
1 LP GAS LINE UP IN MAINTENANCE BLDG. MECH. RM. AND CONNECT TO NEW FURNACES. SEE
MECHANICAL SHT. A-M-103A2. FOR CONTINUATION.
2 CONTRACTOR TO REPLACE EXISTING PROPANE TANK WITH NEW 2000 GAL. TANK FOR (2) 120MBH
FURNACES.
A-P-103A2
MAINTENANCE COMPLEX
PLUMBING SITE PLAN - ALT 2
JKH KHK
1/8" = 1'-0"1 MAINTENANCE COMPLEX PLUMBING SITE PLAN - ALTERNATE 2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
A/E OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
February 22, 2021Revisions: Date:
N/A
BID DOCUMENT
ofDwg.
John Gallup & Associates, LLC 3225 Shallowford Rd NE Suite 830 Marietta, GA 30062 770-321-4040
CONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANT
Miramar National Cemetery 5795 Nobel Drive, San Diego, CA 92122
892PC2037.23
PHASE 2 DEVELOPMENT
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1
DI S AB LE D V E T E R AN + E M P LOY E E OW N E D
www.davyarchitecture.com 211 243
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text
200 / 164 SF
AutoCAD SHX Text
AutoCAD SHX Text
GUARD
AutoCAD SHX Text
HONOR
AutoCAD SHX Text
- / 20 SF
AutoCAD SHX Text
AutoCAD SHX Text
STOR.
AutoCAD SHX Text
- / 80 SF
AutoCAD SHX Text
AutoCAD SHX Text
COTR
AutoCAD SHX Text
AutoCAD SHX Text
CORR.
AutoCAD SHX Text
- / 50 SF
AutoCAD SHX Text
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
UNISEX
AutoCAD SHX Text
- / 30 SF
AutoCAD SHX Text
AutoCAD SHX Text H.A.C.
AutoCAD SHX Text
- / 90 SF
AutoCAD SHX Text
AutoCAD SHX Text
ALCOVE
AutoCAD SHX Text
COMPUTER
AutoCAD SHX Text
- / 17 SF
AutoCAD SHX Text
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
395 / 536 SF
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
LUNCH
AutoCAD SHX Text
241 / 476 SF
AutoCAD SHX Text
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
MENS
AutoCAD SHX Text
109 / 204 SF
AutoCAD SHX Text
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
WOMENS
AutoCAD SHX Text
35 / 143 SF
AutoCAD SHX Text
AutoCAD SHX Text
VEST.
AutoCAD SHX Text
BOOT
AutoCAD SHX Text
190 / 198 SF
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
FOREMANS
AutoCAD SHX Text
- / 192 SF
AutoCAD SHX Text 109A
AutoCAD SHX Text
AREA
AutoCAD SHX Text
COVERED
AutoCAD SHX Text
- / 116 SF
AutoCAD SHX Text
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
- / 32 SF
AutoCAD SHX Text
AutoCAD SHX Text
CTRL.
AutoCAD SHX Text
IRR.
AutoCAD SHX Text 8T
AutoCAD SHX Text 8T
AutoCAD SHX Text 8T
AutoCAD SHX Text 8T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SB
AutoCAD SHX Text
SB
AutoCAD SHX Text
600 / 805 SF
AutoCAD SHX Text
AutoCAD SHX Text
BAY
AutoCAD SHX Text
WASH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LP
AutoCAD SHX Text
AutoCAD SHX Text
LP
AutoCAD SHX Text
05.) NO PIPING SHALL RUN EXPOSED IN FINISHED AREAS.
09.) INSTALL ALL REQUIRED CLEANOUTS TO CLEAR EQUIPMENT AND FIXTURES.
01.) THE PLUMBING WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE APPLICABLE PLUMBING AND BUILDING CODES AS WELL AS ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING
CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY.
02.) ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES BEFORE PROCEEDING WITH THE
INSTALLATION.
03.) INVERT ELEVATIONS AND EXACT LOCATIONS OF ALL EXISTING UTILITIES SHALL BE CHECKED BEFORE PROCEEDING WITH NEW
WORK.
04.) NO CHANGES ARE TO BE MADE IN PLUMBING LAYOUT WITHOUT WRITTEN PERMISSION BY THE ARCHITECT OR ENGINEER.
06.) CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FOR PAYING RELATED FEES.
07.) ROUGHING DIMENSIONS OF TOILET FIXTURES MUST BE COORDINATED WITH THE GENERAL CONTRACTOR.
08.) PROVIDE SHUTOFF VALVES FOR WATER ENTRANCE TO THE BUILDING. PROVIDE DIELECTRIC FITTINGS OR COUPLINGS WHEREVER DISSIMILAR METALS ARE
JOINED.
10.) ALL WORK SHALL BE PROPERLY TESTED, BALANCED, AND CLEANED AND DISINFECTED. PROVIDE A ONE YEAR WARRANTY
FROM DATE OF FINAL INSPECTION ON ALL PARTS AND LABOR.
11.) PITCH ALL WASTE AND SOIL PIPING AT MAXIMUM SLOPE POSSIBLE, BUT NOT LESS THAN 1/8" PER FOOT, EXCEPT WHERE
NOTED.
12.) PROVIDE ALL PIPE OPENINGS THROUGH PARTITIONS WITH PIPE SLEEVES. PENETRATING FIRE RATED PARTITIONS, THE SPACE
BETWEEN THE PIPE AND THE SLEEVE SHALL BE SEALED WITH FIRE STOPPING MATERIAL.
15.) PURGE ALL WATER LINES BEFORE FINAL CONNECTION.
14.) CONTRACTORS ARE TO EXAMINE ALL FIXTURE SCHEDULES, LEGENDS AND RELATED MISCELLANEOUS DETAILS BEFORE PROCEEDING WITH ANY ROUGH-IN
WORK.
16.) NO PVC ABOVE GRADE UNLESS APPROVED BY THE OWNER.
13.) ALL FLOOR DRAINS IN DRY AREAS SHALL HAVE TRAP PRIMERS.
MECHANICAL CONTRACTOR
ELECTRICAL CONTRACTOR
POINT OF CONNECTION
B/G
POC
MC
EC
BELOW GRADE
PLUMBING VENT (V)
CONDENSATE DRAIN
PLUMBING CONTRACTOR
ABOVE FINISHED FLOOR/GRADE
FIXTURE IDENTIFICATION
SANITARY WASTE (SS) - BELOW SLAB/GRADE
FIRE PROTECTION CONTRACTOR
GCO
SD
FPC
OD
FD
AS
B/F
GRADE CLEANOUT
STORM OVERFLOW DRAIN
STORM ROOF DRAIN
BELOW FLOOR
FLOOR DRAIN
ANGLESTOP
WCO
DCO
A/C
FCO
CO
PC
VTR
WALL CLEANOUT
DOUBLE CLEANOUT
ABOVE CEILING
FLOOR CLEANOUT
CLEANOUT
VENT THRU ROOF
AFF/AFG
IW INDIRECT WASTE
PLAN NOTE
BALL VALVE
CD
PIPE UP/DOWN
HOT WATER (HW)
COLD WATER (CW)
EQP
CONNECTION TO EXISTING
DIRECTION OF FLOW
AFF ABOVE FINISH FLOOR
SOFT COPPER PIPING UNDERFLOOR (CW SHOWN)
SS
NATURAL GAS LINEG
AIR INTAKE LINEA
17.) CONTRACTOR SHALL VISIT AND FIELD VERIFY SITE CONDITION PRIOR TO START OF NEW WORK.
OVERFLOW DRAIN (OD-1)
SA
SA
SA
APPROVED MANUFACTURERS:
DESIGNATION
JOSAM, J.R. SMITH, PPP INC, ZURN, WADE
P.D.I. SYMBOLS
C
B
A
33-60
12-32
1-11
FIXTURE UNITS
1"
3/4"
CONNECTION SIZE
1/2"
ADULTP-201 URINAL: WALL MOUNTED, FLUSH VALVE TYPE
AGE
GROUPDESIG
FIXTURE
AMERICAN STANDARD 6541.132 KOHLER, ELJER
MANUFACTURERINGFIXTURE
DESCRIPTION COMPANY NUMBER
MODEL APPROVED
FIXTURE EQUAL & APPROVED EQUALS
MANUFACTURER, DESCRIPTION OF VALVES, FAUCETS, ACCESSORIES
SINK: ONE COMPARTMENT, STAINLESS STEEL, H & CW HAND FAUCET W/ WRIST BLADE HANDLES, 7 1/2" DEEP SKADULTSP-528 JUST SL-2131-A-GR ELKAY JUST FAUCET JTR-50, JB-99 DRAIN
WATER CLOSET: FLOOR MOUNTED, FLUSH VALVE TYPE
ADULTP-101
ADULTP-101
AMERICAN STANDARD
AMERICAN STANDARD
3451.660
3043.660
KOHLER, ELJER
KOHLER, ELJER
WATER CLOSET: FLOOR MOUNTED, FLUSH VALVE TYPE
SLOAN OPTIMA 186 ES-S FLUSH VALVE, ZURN CARRIER
SLOAN OPTIMA 180 ES-S FLUSH VALVE, CHURCH 9500C WHITE OPEN FRONT SEAT, ZURN CARRIER
SLOAN OPTIMA 180 ES-S FLUSH VALVE, CHURCH 9500C WHITE OPEN FRONT SEAT, ZURN CARRIER
MOP SINK: TERRAZZO, 24 X24X12 NEO-CORNER, FAUCET W/ VACUUM BREAKER
TRAP PRIMER VALVE: UNDER LAV EXPOSED TRAP PRIMER VALVE FOR ONE FLOOR DRAIN
DISTRIBUTION UNIT FOR TRAP PRIMER VALVE W/ ONE THRU FOUR 1/2" OUTLET AS REQUIRED
TRAP PRIMER VALVE: BACKFLOW PREVENTER SEAL, VACUUM BREAKER, FOR ONE OUTLET OR CONNECT TO DU(S) TP-1 -
-WCO
FCO
LTPV
DU
-FD-1
P-502
WALL CLEANOUT
FLOOR CLEANOUT
FLOOR DRAIN: TOILET ROOMS FINISHED AREAS
PPP, INC PRIMERITE
J.R. SMITH
JOSAM
J.R. SMITH
PPP, INC
4020S
DU-2, DU-3, DU-4
SERIES 88250-10-90
J.R.SMITH
FIAT
TSBC-1611
PPP, INC
PPP, INC
ZURN, WADE
JOSAM, WADE, ZURN
JOSAM, WADE, ZURN
STERN WILLIAMS
JOSAM, WADE, ZURN 6" DIAMETER VANDAL PROOF NICKEL BRONZE STRAINER, PROVIDE TRAP PRIMER
T-10-VB FAUCET, T-40 M0P HANGER, T-35 HOSE & BRACKET, C-10 SILAPRENE SEALANT
JOSAM, WADE, ZURNGCO - GROUND CLEANOUT J.R. SMITH 4250
THERMOSTATIC MIXING VALVE SYMMONS 5-120 SPEAKMAN, WATTS-TMV-1
MARK
SERVICE
GPM
TYPE
HEAD (FT)
RPM
HP
VOLTAGE/PHASE
MODEL NO.
MANUFACTURER
REMARKS
SUMP SIZE
EWH-1
HOT WATER
STORAGE TANK TYPE
BTH-150
A.O. SMITH
ASME RATED T&P VALVE
MARK
SERVICE
GALLAON CAP.
TYPE
RECOVERY @ 90°
GAS (MBH)
MODEL NO.
MANUFACTURER
REMARKS
RISE (GPH)
120/1VOLTAGE/PHASE
HWRP-1
HOT WATER RETURN LINE
IN-LINE
115/1
0.33
2400 SERIES
TACO
STAINLESS STEEL, FLANGED
ELECTRIC WATER COOLER: ALL STAINLESS STEEL FINISH, 1/5 HP COMPRESSOR, HI-LO CONFIGURATIONADULTSP-604 ELKAY EZSTLG8 HALSEY TAYLOR, SUNROC 7.5 GPH @ 90°F AMBIENT IN & 50°F @ SPOUT
P-401 AMERICAN STANDARD SLOAN OPTIMA ETF-600 FAUCET, TRUBRO LAVGUARD, OR MOEN 8301 OR KOHLER K-13662LAVATORY: WALL-HUNG, ENAMELED CAST IRON, 4" CENTER FAUCET HOLES LUCERNE 0355.012 KOHLER, ELJERADULT
P-413 AMERICAN STANDARD KOHLER, ELJERADULT SLOAN OPTIMA ETF-600 FAUCET, TRUBRO LAVGUARD, OR MOEN 8301 OR KOHLER K-13662LAVATORY: DROP-IN, MANUAL HAND WASHING FAUCET AQUALYN 0475.020
-FS-1 FLOOR SINK: FIRE RISER ROOM ZURN Z1900 JOSAM, WADE, ZURN SANI-FLOOR RECEPTOR, DEEP CAST IRON BODY, LIGHT DUTY GRATE WITH 1/2" SLOTTED OPENINGS
ET-1 AMTROL WATTS, PROFLO- THERMAL EXPANSION TANK ST-5-C
WB-1 OATEY
ICE BOX (METAL) 38529 EASTMAN, PLUMBEST
P-801 WOODFORD JOSAM, J.R. SMITH- NON-FREEZE WALL HYDRANT B65
EWH-2
HOT WATER
STORAGE TANK TYPE
DEL-20
A.O. SMITH
ASME RATED T&P VALVE
208/1
ADULTP-202 URINAL: WALL MOUNTED, FLUSH VALVE TYPE AMERICAN STANDARD 6541.132 KOHLER, ELJER SLOAN OPTIMA 186 ES-S FLUSH VALVE, ZURN CARRIER
A-P-301
PLUMBING SCHEDULES
JKH KHK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
A/E OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
February 22, 2021Revisions: Date:
N/A
BID DOCUMENT
ofDwg.
John Gallup & Associates, LLC 3225 Shallowford Rd NE Suite 830 Marietta, GA 30062 770-321-4040
CONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANT
Miramar National Cemetery 5795 Nobel Drive, San Diego, CA 92122
892PC2037.23
PHASE 2 DEVELOPMENT
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1
DI S AB LE D V E T E R AN + E M P LOY E E OW N E D
www.davyarchitecture.com 212 243
AutoCAD SHX Text
%%UPLUMBING GENERAL NOTES:
AutoCAD SHX Text
%%UPLUMBING SYMBOLS AND LEGEND
AutoCAD SHX Text
AutoCAD SHX Text
FLUSH VALVE WATER CLOSET (ADA)
AutoCAD SHX Text
ROUGH-IN SCHEDULE
AutoCAD SHX Text
CONNECTION SIZE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text W
AutoCAD SHX Text V
AutoCAD SHX Text
CW
AutoCAD SHX Text
HW
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 3"
AutoCAD SHX Text
WC
AutoCAD SHX Text
MS
AutoCAD SHX Text
LV
AutoCAD SHX Text
SK
AutoCAD SHX Text
FD
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
WH
AutoCAD SHX Text
MOP SINK
AutoCAD SHX Text
WALL HUNG LAVATORY (ADA)
AutoCAD SHX Text
COUNTERTOP SINGLE COMP. SINK
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
AutoCAD SHX Text 1"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 2"
AutoCAD SHX Text
EWC
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
SHOCK ABSORBER SCHEDULE
AutoCAD SHX Text
PLUMBING FIXTURE SPECIFICATION SCHEDULE
AutoCAD SHX Text
PUMP SCHEDULE
WATER HEATER SCHEDULE
1/2"
FIN. FLOOR
FLOOR DRAIN
1/2"
1/2"
FLOOR DRAIN TRAP
PRIMER DISTRIBUTION
FLOOR DRAIN
CEILING
WALL
UNIT
TRAP PRIMER VALVE
DOMESTIC WATER LINE
PRECISION PLUMBING PRODUCTS
MODEL #P-2 (1 OR 2 DRAINS)
TRAP PRIMER DETAIL09 SCALE: NONE
ACCESS COVER
FINISHED WALL
CLEANOUT PIPE
CLEANOUT TEE
SPRINKLER RISER DETAIL01 SCALE: NONE
CLEANOUT TO WALL DETAIL03 SCALE: NONE
2-WAY CLEANOUT TO GRADE DETAIL06 SCALE: NONE
CLEANOUT TO GRADE (GCO) DETAIL02 SCALE: NONE
TYPICAL GAS SERVICE METER DETAIL04 SCALE: NONE
FLOOR DRAIN DETAIL07 SCALE: NONE
WATER PIPE ENTRY DETAIL10 SCALE: NONE
CONDENSATE
P-TRAP
TO SINK
DRAIN
NOTES TO DESIGNER:
1. THIS DETAIL IS TO BE USED FOR OTHER THAN POURED-IN-PLACE CONCRETE WALLS.
SEE DETAILS FOR OTHER TYPES OF CONSTRUCTION..
TO PIPE SLEEVE.
UL LISTED SEALANT &
NON-INSULATED PIPE
EQUAL IN RATING TO
THE WALL STRUCTURE.
FIRE SAFING INSULATION
PLATE. CONTINUOUS WELD
PIPE SLEEVE
PIPE
PIPELC
METAL JACKET
INSULATED
PIPE INSULATION
PIPE
PLATE. CONTINUOUS
WELD TO PIPE
SLEEVE.
WALL STRUCTURE.
PROVIDE INSULATION
SHIELD WHERE REQ'D.
BAR JOIST OR BEAM
(SECURE TO ROOF MEMBERS)
BRIDGING AS REQ'D.
PIPE CLEVIS
(SIZE AS REQ'D.)
PIPE HANGER, 6'-0" O.C.
DOUBLE-NUTTED EA. END,
2 WASHERS @ TOP ONLY
THREADED ROD
TO STRUCTURE
SLEEVE
VENT THRU ROOF
STRIP.
1 5/8" x 1'- 0"
FIBER EDGE
FLASHING SLEEVE
M
IN
IM
U M
12" MIN.
ROOF CONSTRUCTION
ROOF
PIPE FULL SIZE TO
P-TRAP TAILPIECE
DRAIN VALVE
CEILING
D
T&P RELIEF VALVE
THERMOMETER
(TYPICAL)
BALL VALVE (TYPICAL)
COLD WATER SUPPLY
CHECK VALVE (TYPICAL)
NOTE:
1. PIPE SIZES AND ROUTING SHOWN ON PLANS.
THERMAL EXPANSION TANK
DETA-12 CW&HW
DRAIN PAN
H.W. SUPPLY
HEAT TRAP
INSULATE INLET PIPE
THROUGH THIS ELBOW
INSULATE FIRST 8'-0"
OF OUTLET PIPING
PIPE HANGER DETAIL11 SCALE: NONE
PIPE PENETRATION DETAIL12 SCALE: NONE
WATER HEATER DETAIL13 SCALE: NONE
CONDENSATE DRAIN DETAIL05 SCALE: NONE
VENT THRU ROOF DETAIL08 SCALE: NONE
A-P-401
PLUMBING DETAILS
JKH KHK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
A/E OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
February 22, 2021Revisions: Date:
N/A
BID DOCUMENT
ofDwg.
John Gallup & Associates, LLC 3225 Shallowford Rd NE Suite 830 Marietta, GA 30062 770-321-4040
CONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANT
Miramar National Cemetery 5795 Nobel Drive, San Diego, CA 92122
892PC2037.23
PHASE 2 DEVELOPMENT
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1
DI S AB LE D V E T E R AN + E M P LOY E E OW N E D
www.davyarchitecture.com 213 243
AutoCAD SHX Text
GROOVED OUTLET
AutoCAD SHX Text
FIREMATIC SIAMESE F.D.C.
AutoCAD SHX Text
TO SYSTEM
AutoCAD SHX Text
FIREMATIC MODEL CVB-1 MAINTENANCE CHECK VALVE
AutoCAD SHX Text
PIPING TO FDC LOCATION
AutoCAD SHX Text (see plan)
AutoCAD SHX Text
FIREMATIC MODEL L FL. X GR ALARM VA. W/BASIC TRIM AND (OPT) RETARD CHAMBER.
AutoCAD SHX Text
GROUND LEVEL
AutoCAD SHX Text M.J. x FL. ADAPTOR
AutoCAD SHX Text
AMES 2000 SS DOUBLE CHECK VALVE
AutoCAD SHX Text
MAIN DRAIN VA.
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
FIREMATIC ALARM BELL
AutoCAD SHX Text
FLEXIBLE COUPLING
AutoCAD SHX Text
GROOVED 90° ELBOW
AutoCAD SHX Text
34" ALL THR. ROD
AutoCAD SHX Text
"J" BOLT OR TIE BOLT
AutoCAD SHX Text
HEX NUT & WASHER
AutoCAD SHX Text
D.I.P. RISER
AutoCAD SHX Text
U.G. PIPING
AutoCAD SHX Text
THRUST BLOCK (PER NFPA 24)
AutoCAD SHX Text
REFER TO SPECIFICATIONS FOR PLASTIC TYPE SEWER & VENT PIPING OPTIONS.
AutoCAD SHX Text
"TYLER" #5462
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
SEWER
AutoCAD SHX Text
TO SUIT
AutoCAD SHX Text 6"
AutoCAD SHX Text
TYPE HEAD
AutoCAD SHX Text
COUNTERSUNK
AutoCAD SHX Text
BRASS CLEANOUT
AutoCAD SHX Text
CLEANOUT
AutoCAD SHX Text
TWO-WAY
AutoCAD SHX Text
CAST IRON
AutoCAD SHX Text
CONC. PAD
AutoCAD SHX Text
REFER TO SPECIFICATIONS FOR PLASTIC TYPE SEWER & VENT PIPING OPTIONS.
AutoCAD SHX Text
TYPE HEAD
AutoCAD SHX Text
COUNTERSUNK
AutoCAD SHX Text
BRASS CLEANOUT
AutoCAD SHX Text
SEWER
AutoCAD SHX Text
TO SUIT
AutoCAD SHX Text 6"
AutoCAD SHX Text
18" SQUARE
AutoCAD SHX Text
CONC. PAD
AutoCAD SHX Text
OCCURS AT END OF LINE.
AutoCAD SHX Text
1/8 BEND IF CLEANOUT
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
FOR CONTINUATION
AutoCAD SHX Text
INSULATING UNION
AutoCAD SHX Text
AND 3/8" PLUG
AutoCAD SHX Text
GAS COCK(TYP.)
AutoCAD SHX Text
ANNODELESS RISER
AutoCAD SHX Text
REFER TO CIVIL
AutoCAD SHX Text
PLUGGED TEE W/BUSHING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GAS PRESSURE
AutoCAD SHX Text
REGULATOR
AutoCAD SHX Text
AND 3/8" PLUG
AutoCAD SHX Text
TEE W/BUSHING
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
2" CONCRETE PAD
AutoCAD SHX Text
DETAIL FOR CONTINUATION
AutoCAD SHX Text
REFER TO ENTRANCE
AutoCAD SHX Text
ADJUSTABLE STRAINER
AutoCAD SHX Text
FLOOR FINISH
AutoCAD SHX Text
CLAMPING RING
AutoCAD SHX Text
DRAIN PIPE
AutoCAD SHX Text
NON-SHRINK GROUT
AutoCAD SHX Text
FLASHING MEMBRANE
AutoCAD SHX Text
CONCRETE SLAB
AutoCAD SHX Text
NON-SHRINK CONCRETE FILL
AutoCAD SHX Text
PRIMER TAP
AutoCAD SHX Text
SLEEVE END OPEN
AutoCAD SHX Text
WATER TIGHT
AutoCAD SHX Text
SLEEVE
AutoCAD SHX Text
SEAL WATER
AutoCAD SHX Text
CONTINUATION
AutoCAD SHX Text
SEE PLAN FOR
AutoCAD SHX Text
FIN. FLOOR
AutoCAD SHX Text
TIGHT
AutoCAD SHX Text
FLANGES
AutoCAD SHX Text
SIZE AND
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
GATE OR BALL VALVE
AutoCAD SHX Text
FLUSH TO GRADE
AutoCAD SHX Text
WITH CAST IRON COVER
AutoCAD SHX Text
CONCRETE VALVE BOX
AutoCAD SHX Text
3/4"%%UWH-1
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
EXTERIOR WALL
GATE VALVE
ARCHITECT RESERVES THE RIGHT TO RELOCATE ACCESS PANELS WITHOUT ADDITIONAL
COST. CONTRACTOR MAY RELOCATE TRAP PRIMERS TO ABOVE CEILINGS IF ALLOWED BY
ARCHITECT, IF RELOCATED THE CONTRACTOR SHALL PROVIDE ACCESS PANEL IN GYPBOARD
CEILINGS.
COORDINATE INSTALLATION OF ALL ACCESS PANELS WITH ARCHITECT PRIOR TO INSTALLATION.
INSTALL AIR CHAMBERS ON ALL EACH HOT & COLD WATER ROUGH-IN, ALSO
PROVIDE SCHOCK ABSORBERS ON ALL QUICK CLOSING VALVES.
VERIFY ALL LOCATIONS OF HANDICAPPED PLUMBING FIXTURES WITH ARCHITECTURAL DRAWINGS.
REFER TO FLOOR PLANS FOR PLUMBING FIXTURE DESIGNATIONS. CONTRACTOR WILL BE
RESPONSIBLE FOR PROVIDE PLUMBING FIXTURES AS SHOWN ON THE PLUMBING AND
ARCHITECTURAL DRAWINGS.
PLUMBING RISER GENERAL NOTES:
5.
2.
3.
4.
1.
CEILING
1st FLOOR
ROOF
3"
SS
3"FS-1
2"
WCO
P
4"
1"
WC-1
1 1/2"
2"
3"FD-1
3"
SS
2"
L-1
4"
2"
3/4"
4"
1 1/2"
WCO
CEILING
1st FLOOR
ROOF
4"
1"
WC-1
2"
3"FD-1
3"
SS
2"
4"
L-1
2"
4"4"
3"
WCO
3"
2"2"
1/2" 1/2" 1"
1/2"
1 1/4"
CEILING
1st FLOOR
ROOF
1 1/2"
SK-2
2"
SS
WCO
1/2"
P
CEILING
1st FLOOR
ROOF
1 1/2"
SK-1
2"
SS
WCO
1/2"
P
P
4"
1"
WC-1
1 1/2"
2"
3"FD-1
3"
SS
2"
L-1
2"
3/4"
4"
1 1/2"
WCO
2"
2"
1/2"
1 1/4"
SA-ASA-A
SA-B SA-B
SA-A
SA-A
SA-A
SA-A
3"FD-1
WCO
2"
3"
MS-1
1/2"
P
P
1 1/2"
EWC-1
2"
SS
WCO
1/2"
A-P-501
PLUMBING RISERS
JKH KHK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
A/E OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
February 22, 2021Revisions: Date:
N/A
BID DOCUMENT
ofDwg.
John Gallup & Associates, LLC 3225 Shallowford Rd NE Suite 830 Marietta, GA 30062 770-321-4040
CONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANTCONSULTANT
Miramar National Cemetery 5795 Nobel Drive, San Diego, CA 92122
892PC2037.23
PHASE 2 DEVELOPMENT
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1
DI S AB LE D V E T E R AN + E M P LOY E E OW N E D
www.davyarchitecture.com 214 243
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
PLUMBING RISER DIAGRAM
fl
C:
D
E
F o,_ u: Revision Date
VA FORM 08 - 6231 11
4 CJ
ELECTRICAL GENERAL NOTES AND SPECIFICATIONS
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF
THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE NATIONAL,
STATE, AND LOCAL CODES.
2. THE DRAWINGS ARE INTENDED TO COMPLY WITH LISTED CODES,
ORDINANCES, REGULATIONS AND STANDARDS. WHERE DISCREPANCIES
OCCUR, IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE IN
WRITING AND ASK FOR AN INTERPRETATION. SHOULD INSTALLED
MATERIALS OR WORKMANSHIP FAIL TO COMPLY, THE CONTRACTOR IS
RESPONSIBLE FOR CORRECTING THE IMPROPER INSTALLATION. WHERE
SIZES, CAPACITIES, OR OTHER SUCH FEATURES ARE REQUIRED IN
EXCESS OF MINIMUM CODE OR STANDARDS REQUIREMENTS, PROVIDE
THOSE SPECIFIED OR SHOWN.
16. SEAL ALL PENETRATIONS OF FIRE RATED PARTITIONS DUE TO THE
INSTALLATION OF ELECTRICAL SYSTEMS. EACH PENETRATION SHALL BE
SEALED IN SUCH A MANNER THAT THE FIRE RATING OF THE PARTITION IS
MAINTAINED.
17. CONCEAL ELECTRICAL WORK IN WALLS, FLOORS, CHASES, UNDER
FLOORS, UNDERGROUND AND ABOVE CEILINGS EXCEPT WHERE SHOWN
OR SPECIFIED TO BE EXPOSED. EXPOSED IS UNDERSTOOD TO MEAN
OPEN TO VIEW. WHERE CONDUIT IS SHOWN CONCEALED BELOW THE
SURFACE OF THE FLOOR, CONDUIT MUST BE INSTALLED BELOW THE
FLOOR SLAB UNLESS WRITTEN APPROVAL HAS BEEN OBTAINED FROM
THE STRUCTURAL ENGINEER OF RECORD TO ALLOW INSTALLATION
WITHIN THE CONCRETE SLAB.
18. UNLESS OTHERWISE NOTED, REMOVE ELECTRICAL MATERIALS AND
EQUIPMENT FROM AREAS INDICATED FOR DEMOLITION. REMOVE
UNUSED CONDUIT TO THE EXTENT NECESSARY TO ACCOMMODATE NEW
WORK AND WHERE CONDUIT IS VISIBLE ABOVE THE FLOOR LINE. SEAL
ABANDONED CONDUITS THAT REMAIN IN PLACE BEHIND WALLS OR IN
FLOOR SLABS. REMOVE WIRING FROM ABANDONED CONDUIT.
37. CONCRETE PIERS AND POLE BASES FOR LIGHT POLES AND THEIR
ASSOCIATED FIXTURES SHALL BE DESIGNED BY A STRUCTURAL
ENGINEER LICENSED TO PRACTICE IN THE STATE OF TEXAS.
38. PROVIDE LAMPS FOR ALL LIGHT FIXTURES SHOWN ON THE DRAWINGS.
39. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT
LOCATION OF LIGHT FIXTURES AND CEILING TYPES. VERIFY CEILING
TYPES WITH OWNER'S REPRESENTATIVE. COORDINATE LIGHT FIXTURE
MOUNTING HARDWARE AND TRIM TYPES WITH ACTUAL CEILING TYPES
TO ENSURE PROPER INSTALLATION OF LIGHT FIXTURES.
40. FOR ALL EXISTING LIGHT FIXTURES SHOWN TO REMAIN OR TO BE
RELOCATED: CLEAN, RELAMP, REPLACE ALL CRACKED OR YELLOWED
LENSES, REPLACE BALLASTS AS REQUIRED FOR ALL LAMPS TO BE
FULLY OPERATIONAL. NEW FIXTURES, MAY BE SUBSITUTED FOR
EXISTING FIXTURES IN LIEU OF CLEANING AND REPAIR. ANY FIXTURE
SUBSTITUTIONS MUST BE APPROVED IN WRITING BY OWNER'S
REPRESENTATIVE PRIOR TO INSTALLATION.
3. THE INTENT OF THE DRAWINGS IS TO ESTABLISH THE TYPES OF
SYSTEMS AND FUNCTIONS, BUT NOT TO SET FORTH EACH ITEM
ESSENTIAL TO THE FUNCTIONING OF THE SYSTEM. ELECTRICAL
DRAWINGS ARE GENERALLY SCHEMATIC AND SHOW APPROXIMATE
LOCATION AND EXTENT OF WORK. ELECTRICAL DRAWINGS MAY NOT BE
DRAWN EXACTLY TO SCALE. THE DRAWINGS DO NOT SHOW EVERY ITEM
OF EQUIPMENT, BOX, DEVICE, CONDUCTOR, ETC. REQUIRED FOR THE
ELECTRICAL SYSTEM. HOWEVER, THE SCOPE OF WORK INCLUDES
PROVIDING ALL LABOR, MATERIAL, AND EQUIPMENT REQUIRED FOR A
COMPLETE AND FULLY FUNCTIONAL ELECTRICAL SYSTEM AS SHOWN IN
SCHEMATIC FORM ON THE DRAWINGS. THE CONTRACTOR IS
RESPONSIBLE FOR COORDINATING EXACT INSTALLATION AND ROUTING
OF ALL ELECTRICAL EQUIPMENT WITH OTHER TRADES. IN CASE OF
DOUBT AS TO WORK INTENDED, OR IF AMPLIFICATION OR CLARIFICATION
IS NEEDED, REQUEST INSTRUCTIONS FROM THE OWNER'S
REPRESENTATIVE.
MATERIALS AND EQUIPMENT TO BE REMOVED, EXCEPT ITEMS 41. ALL PANELS SHALL BE PANELBOARD CONSTRUCTION WITH COPPER SPECIFICALLY LISTED TO BE RELOCATED OR DELIVERED TO THE OWNER, BLISSES AND BOLT-IN CIRCUIT BREAKERS.
4. WHERE DISCREPANCIES OCCUR BETWEEN DRAWINGS AND/OR
SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT SHALL PREVAIL.
5. REVIEW PERTINENT DRAWINGS AND ADJUST THE WORK TO CONDITIONS
SHOWN. WHERE DISCREPANCIES OCCUR BETWEEN DRAWINGS,
SPECIFICATIONS, AND ACTUAL FIELD CONDITIONS, IMMEDIATELY NOTIFY
THE OWNER'S REPRESENTATIVE FOR HIS INTERPRETATION.
6. VISIT THE SITE AND ASCERTAIN THE CONDITIONS TO BE MET AND THE
WORK TO BE ACCOMPLISHED IN REMOVING AND MODIFYING THE
EXISTING WORK, AND INSTALLING THE NEW WORK. FAILURE TO COMPLY
WITH THIS PROVISION SHALL NOT CONSTITUTE GROUNDS FOR
ADDITIONAL PAYMENT IN CONNECTION WITH REMOVING OR MODIFYING
PART OF THE EXISTING INSTALLATIONS AND INSTALLING NEW OR
TEMPORARY WORK.
7. OBTAIN CERTIFICATES OF INSPECTION AND OTHER PERMITS REQUIRED
AS A PART OF THE WORK. THE CONTRACTOR SHALL OBTAIN TIMELY
INSPECTIONS BY JURISDICTIONAL AUTHORITIES AT SUCH TIMES AS ARE
REQUIRED BY THOSE AUTHORITIES. COSTS ASSOCIATED WITH
EXPOSING WORK NOT INSPECTED IN A TIMELY MANNER, OR TESTING
REQUIRED BY AUTHORITIES TO DEMONSTRATE COMPLIANCE WITH
CODES OR STANDARDS SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR. PAY ALL FEES REQUIRED FOR INSPECTION AND
PERMITTING.
8. WARRANTY ALL WORKMANSHIP INCLUDING LABOR, MATERIAL, AND
EQUIPMENT FOR A PERIOD OF ONE YEAR AFTER SUBSTANTIAL
COMPLETION OF THE WORK.
9. AN ACCEPTABLE CONTRACTOR FOR THE ELECTRICAL WORK SHALL
HAVE PERSONNEL WITH EXPERIENCE, TRAINING AND SKILL TO PROVIDE
A PRACTICAL WORKING SYSTEM. THE CONTRACTOR MAY BE REQUIRED
TO FURNISH ACCEPTABLE EVIDENCE OF HAVING INSTALLED NOT LESS
THAN THREE SYSTEMS OF SIZE AND TYPE COMPARABLE TO THIS
PROJECT. THE SYSTEMS MUST HAVE SERVED SATISFACTORILY FOR
NOT LESS THAN THREE YEARS. THE CONTRACTOR SHALL EMPLOY AND
UTILIZE LICENSED AND CERTIFIED PROFESSIONALS AND TRADESMEN
AS REQUIRED BY LOCAL JURISDICTIONS.
10. VERIFY THE REQUIREMENTS OF THE ELECTRIC UTILITY PROVIDING
SERVICE TO THE PROJECT. PROVIDE ALL LABOR, MATERIAL, AND
EQUIPMENT REQUIRED BY THE ELECTRIC UTILITY FOR SERVICE TO THE
PROJECT. ALL FEES REQUIRED BY THE ELECTRIC UTILITY FOR
PROVIDING SERVICE TO THE PROJECT SHALL BE PAID BY THE OWNER.
11. VERIFY THE REQUIREMENTS OF THE TELEPHONE UTILITY PROVIDING
SERVICE TO THE PROJECT. PROVIDE ALL LABOR, MATERIAL, AND
EQUIPMENT REQUIRED BY THE TELEPHONE UTILITY FOR SERVICE TO
THE PROJECT. ALL FEES REQUIRED BY THE TELEPHONE UTILITY FOR
PROVIDING SERVICE TO THE PROJECT SHALL BE PAID BY THE OWNER.
12. PROVIDE NEW PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED
IN PRODUCTION OF SUCH EQUIPMENT. PROVIDE THE MANUFACTURER'S
LATEST STANDARD DESIGN FOR THE TYPE OF PRODUCT SPECIFIED.
PRODUCTS MUST CONFORM TO REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODE. WHERE UNDERWRITERS' LABORATORIES HAVE SET
STANDARDS, LISTED PRODUCTS AND ISSUED LABELS, PRODUCTS USED
MUST BE LISTED AND LABELED BY UL. EQUIPMENT MUST BE DELIVERED
WITH A HARD SURFACE, FACTORY-APPLIED FINISH SO THAT NO
ADDITIONAL FIELD PAINTING IS REQUIRED EXCEPT FOR TOUCH-UP
AS REQUIRED.
13. SUBSTITUTE MATERIALS OR EQUIPMENT SUBMITTED UNDER AN
"OR EQUAL" BASIS MUST BE SUBMITTED IN WRITING FIVE (5) DAYS PRIOR
TO BID OPENING TO THE OWNER'S REPRESENTATIVE. TH� PROPOSED
SUBSTITUTE SUBMISSION SHALL INCLUDE MANUFACTURER'S PUBLISHED
DATA COVERING ALL FEATURES OF THE MATERIAL OR EQUIPMENT.
BECOME THE PROPERTY OF THE CONTRACTOR AND MUST BE
IMMEDIATELY REMOVED FROM THE PROJECT SITE. ELECTRICAL
SERVICES AND CONTROLS TO ITEMS BEING REMOVED MUST BE
DISCONNECTED AND REMOVED COMPLETELY TO THEIR SOURCE OF
SERVICE. WHERE SERVICES ARE REMOVED TO A DISCONNECTING
MEANS, LABEL THEDISCONNECTING MEANS "SPARE". REMOVAL OF
EQUIPMENT MUST NOT INTERFERE WITH EXISTING OPERATIONS.
19. IF CONDUIT, CONDUCTORS, OR OTHER ELECTRICAL EQUIPMENT TO
REMAIN PASSES THROUGH THE AREA OF DEMOLITION, REROUTE THESE
SYSTEMS OUTSIDE THE AREA OF DEMOLITION AS REQUIRED AND
PROVIDE WHATEVER NEW EQUIPMENT IS NECESSARY FOR EXISTING
SERVICES TO REMAIN IN OPERATION.
20. COORDINATE THE ACTUAL LOCATIONS OF ELECTRICAL SWITCHES,
OUTLETS, AND EQUIPMENT WITH BUILDING FEATURES AND EQUIPMENT
AS INDICATED ON ARCHITECTURAL, STRUCTURAL, MECHANICAL AND
PLUMBING DRAWINGS. REVIEW WITH THE OWNER'S REPRESENTATIVE
ANY PROPOSED CHANGES IN SWITCH, OUTLET, OR EQUIPMENT
LOCATION. RELOCATION OF SWITCHES, OUTLETS, OR EQUIPMENT
BEFORE INSTALLATION, OF UP TO 5 FEET FROM THE POSITION
INDICATED, MAY BE DIRECTED BY THE OWNER'S REPRESENTATIVE
WITHOUT ADDITIONAL COST.
21. PROVIDE FINAL CONNECTION TO ALL EQUIPMENT REQUIRING
ELECTRICAL SERVICE.
22. PROVIDE A LOCAL DISCONNECTING MEANS FOR ALL EQUIPMENT
REQUIRING ELECTRICAL SERVICE. SIZE ALL DISCONNECTING MEANS,
UNLESS NOTED OTHERWISE ON DRAWINGS, IN ACCORDANCE WITH THE
OVERCURRENT PROTECTIVE DEVICE FOR EACH CIRCUIT.
23. VERIFY THE LOCATION AND CONNECTED LOAD OF ALL EQUIPMENT
REQUIRING ELECTRICAL SERVICE. ADJUST CIRCUITS SERVING
EQUIPMENT AS NEEDED TO COORDINATE WITH THE EQUIPMENT'S
CONNECTED LOAD.
24. ALL RACEWAYS SHALL BE RUN PARALLEL OR PERPENDICULAR TO
STRUCTURAL MEMBERS, WALLS, CEILINGS OR FLOORS.
25. ALL CONDUIT INSTALLED ABOVE SLAB OR GRADE LEVEL SHALL BE
GALVANIZED RIGID STEEL (GRS), INTERMEDIATE METAL CONDUIT (IMC)
OR ELECTRICAL METAL TUBING (EMT).
26. CONDUIT FITTINGS SHALL BE MADE OF STEEL OR DIE-CAST MATERIAL
AND SHALL BE SET-SCREW OR COMPRESSION TYPE ONLY.
27. ALL EXPOSED HORIZONTAL CONDUIT SHALL BE RUN ABOVE THE BOTTOM
CORD OF THE ROOF JOIST. CONDUIT MAY REST ON THE BOTTOM CHORD
OF JOISTS, BUT MAY NOT BE SUSPENDED BELOW THE JOISTS.
28. ALL EXPOSED OUTLET AND JUNCTION BOXES SUBJECT TO DAMAGE
SHALL BE CAST STEEL. ALL EXPOSED CONDUIT SUBJECT TO DAMAGE
SHALL BE GALVANIZED RIGID STEEL.
29. PREMANUFACTURED WIRING SYSTEMS SUCH AS "BX" OR "MC" CABLE
ARE NOT ALLOWED. ALL CONDUCTORS SHALL BE INSTALLED INSIDE
RACEWAYS.
30. UTILIZE CONDUCTORS WITH INSULATION RATED AT 600V AND INSULATED
WITH "THHN" INSULATION IN DRY LOCATIONS AND "THWN" INSULATION IN
WET LOCATIONS. CONDUCTORS IN FIXTURE CHANNELS AND OTHER
SPECIAL LOCATIONS SHALL BE SPECIFICALLY RATED FOR TEMPERATURE
AS REQUIRED BY THE NATIONAL ELECTRICAL CODE.
31. SIZE ALL CONDUCTORS, UNLESS NOTED OTHERWISE ON DRAWINGS, IN
ACCORDANCE WITH THE OVERCURRENT PROTECTIVE DEVICE FOR EACH
CIRCUIT.
32. CONDUCTORS SHALL BE SIZED BASED UPON USE WITH 75C
TERMINATIONS. FURNISH TERMINATIONS RATED AT 75C FOR ALL
CONDUCTORS OR DERATE CONDUCTORS FOR USE AT 60C. 90C RATED
TERMINATIONS ARE ACCEPTABLE BUT ALL CONDUCTORS USED WITH 90C
TERMINATIONS SHALL BE SIZED BASED UPON THE 75C RATING.
33. PROVIDE A GROUNDING CONDUCTOR IN ALL RACEWAYS.
34. INSTALL A SEPARATE NEUTRAL CONDUCTOR FOR EACH PHASE
14. EQUIPMENT SELECTED MUST CONFORM TO THE BUILDING FEATURES CONDUCTOR ON CIRCUITS SERVING RECEPTACLES.
AND MUST BE COORDINATED WITH THEM. DO NOT PROVIDE EQUIPMENT
WHICH WILL NOT SUIT ARRANGEMENT AND SPACE LIMITATIONS. WHERE 35. THE MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG.
EQUIPMENT IS DESCRIBED BY MANUFACTURER'S DESIGNATIONS, YET
ALTERNATE MANUFACTURERS ARE DESIGNATED IN THE CONTRACT 36. INSTALL #10 AWG CONDUCTORS FOR ALL 20A HOMERUN CIRCUITS DRAWINGS AS ACCEPTABLE SUPPLIERS, SPATIAL CONSIDERATIONS WILL LONGER THAN FIFTY (50) FEET.
BEAR EQUALLY WITH PERFORMANCE CRITERIA IN DETERMINING THE
ACCEPTABILITY OF ALTERNATE EQUIPMENT.
42. SERVE ALL HVAC EQUIPMENT WITH HACR RATED CIRCUIT BREAKERS.
SERVE ALL HID LIGHT FIXTURES WITH HID RATED CIRCUIT BREAKERS.
43. PROVIDE PANELS WITH AIC RATINGS AS INDICATED ON DRAWINGS.
VERIFY AVAILABLE FAULT CURRENT WITH ELECTRICAL UTILITY
PROVIDING SERVICE TO THE SITE. INCREASE AIC RA TINGS OF PANELS IF
REQUIRED TO EXCEED THE AVAILBLE FAULT CURRENT FROM THE
ELECTRIC UTILITY.
44. APPROVED MANUFACTURERERS FOR SWITCHGEAR ARE
CUTLER-HAMMER, GENERAL ELECTRIC, SIEMENS, AND SQUARE D.
45. THE OWNER SHALL SELECT THE COLOR OF WIRING DEVICES AND THEIR
ASSOCIATED PLATES. VERIFY THE COLOR OF WIRING DEVICES AND
PLATES PRIOR TO INSTALLATION. RECEPTACLES SHALL BE HARD USE
SPECIFICATION GRADE RATED FOR 125V/20A, EQUAL TO PASS &
SEYMOUR #5352 SERIES. SWITCHES SHALL BE HEAVY DUTY
SPECIFICATION GRADE RATED FOR 277V/20A, EQUAL TO PASS &
SEYMOUR #20AC1 SERIES. APPROVED MANUFACTURERERS FOR WIRING
DEVICES, SHALL BE HUBBELL, LEVITON, AND PASS & SEYMOUR.
46. THE OWNER SHALL SELECT THE COLOR OF OCCUPANCY SENSORS.
VERIFY THE COLOR OF OCCUPANCY SENSORS PRIOR TO INSTALLATION.
WALL MOUNTED OCCUPANCY SENSORS SHALL BE NOVITAS #01-400.
IN ROOMS, THE SENSING UNIT FOR CEILING MOUNTED OCCUPANCY
SENSORS SHALL BE NOVITAS #01-190. IN CORRIDORS, THE SENSING
UNIT FOR CEILING MOUNTED OCCUPANCY SENSORS SHALL BE
NOVITAS #01-100. THE POWERPACK MODULE FOR CEILING MOUNTED
OCCUPANCY SENSORS SHALL BE NOVITAS #13-051.
47. BE RESPONSIBLE FOR THE COST OF CUTTING AND PATCHING REQUIRED
IN CONNECTION WITH THE WORK. COORDINATE THE WORK TO
ELIMINATE UNNECESSARY CUTTING OF CONSTRUCTION. WHERE IT
BECOMES NECESSARY TO CUT THROUGH WALLS, FLOORS, CEILINGS
AND OTHER CONSTRUCTION TO PERMIT INSTALLATION OF THE WORK,
OR TO REPAIR DEFECTIVE WORK, THE COSTS FOR SUCH CUTTING AND
PATCHING SHALL BE INCLUDED AS PART OF THE WORK. CUTTING OF
STRUCTURAL MEMBERS IS NOT PERMITTED UNLESS SPECIFIC WRITTEN
PERMISSION IS GRANTED BY THE OWNER'S REPRESENTATIVE.
48. EXCAVATE AND BACKFILL AS NECESSARY FOR THE INSTALLATION OF
THE WORK. EXCAVATE TO THE PROPER DEPTH, WITH ALLOWANCES
MADE FOR FLOOR SLABS, FORMS, BEAMS, ETC. COMPACT THE GROUND
UNDER CONDUITS BEFORE CONDUITS ARE INSTALLED. INSTALL
EXTERIOR CONDUITS WITH A MINIMUM OF 30 INCHES OF COVER BELOW
THE FINISHED GRADE, UNLESS OTHERWISE INDICATED. USE SELECTED
SOIL FOR BACKFILLING, FREE FROM ROCKS AND DEBRIS,
PNEUMATICALLY TAMPED WITH 6 INCH LAYERS TO SECURE A FIELD
DENSITY RATIO OF 90 PERCENT. REMOVE FROM THE SITE EXCAVATED
MATERIALS NOT SUITABLE FOR BACKFILL AND NOT USED IN THE
BACKFILL. FIELD CHECK AND VERIFY THE LOCATIONS OF ALL
UNDERGROUND UTILITIES. IN THE EVENT EXISTING UTILITIES ARE
DAMAGED, THEY SHALL BE REPAIRED TO MAKE THEIR OPERATION EQUAL
TO BEFORE ANY TRENCHING WAS STARTED. REPLACE CONCRETE,
CURBS, PAVING AND OTHER SURFACE IMPROVEMENTS CUT DURING
EXCAVATION TO THEIR ORIGINAL CONDITION. IN A LIME STABILIZED
AREA, THE LIME STABILIZATION SHALL BE FULLY RESTORED AFTER THE
EXCAVATION IS COMPLETE.
w,<1
IT]
DA
!ZIA
DA
IZIA
I :c �
I?�
A I I
A 1-----1
A
A
.A
QA
Qi(
I-QA
X A
-$-A
$A
181A
�A
0:A oJ
IZiJ
I tl 9
SYMBOL LEGEND A
DISTRIBUTION PANELBOARD, SURFACE MOUNTED @ CEILING MOUNTED OCCUPANCY SENSOR
BRANCH PANELBOARD, SURFACE MOUNTED $ SINGLE POLE SWITCH, MOUNTED 46" ABOVE FINISHED FLOOR
BRANCH PANELBOARD, FLUSH MOUNTED
TO THE CENTER OF DEVICE, SUBSCRIPTS INDICATE
THE FOLLOWING:
DRY-TYPE TRANSFORMER 3 - 3-WAY SWITCH
4 - 4-WAY SWITCH
2x4 FIXTURE, LETTER INDICATES TYPE K - KEYED SWITCH
2x4 FIXTURE ON AN UNSWITCHED CIRCUIT, 3K - 3-WAY KEYED SWITCH
LETTER INDICATES TYPE 4K - 4-WAY KEYED SWITCH
D1 - 1000W DIMMER
2x2 FIXTURE, LETTER INDICATES TYPE D2 - 2000W DIMMER 2x2 FIXTURE ON AN UNSWITCHED CIRCUIT, M - OCCUPANCY SENSOR
LETTER INDICATES TYPE R - MOTOR RATED SWITCH
WALL MOUNTED FIXTURE, y - MOMENTARY SWITCH []
LETTER INDICATES TYPE � DUPLEX RECEPTACLE, MOUNTED 18" ABOVE FINISHED FLOOR
WALL MOUNTED FIXTURE ON AN TO THE CENTER OF DEVICE, SUBSCRIPTS INDICATE
UNSWITCHED CIRCUIT, LETTER INDICATES TYPE THE FOLLOWING:
• MOUNTED 6" ABOVE COUNTER TO THE CENTER-
4' FIXTURE, LETTER INDICATES TYPE OF DEVICE
G - GROUND FAULT INTERRUPTER TYPE
4' FIXTURE ON AN UNSWITCHED IG - ISOLATED GROUND
CIRCUIT, LETTER INDICATES TYPE WP - WEATHER-PROOF GROUND FAULT
INTERRUPTER TYPE
• 8' FIXTURE, LETTER INDICATES TYPE
� QUADPLEX RECEPTACLE, MOUNTED 18" ABOVE FINISHED FLOOR
TO THE CENTER OF DEVICE, SUBSCRIPTS INDICATE
• 8' FIXTURE ON AN UNSWITCHED THE FOLLOWING:
CIRCUIT, LETTER INDICATES TYPE • MOUNTED 6" ABOVE COUNTER TO THE CENTER-
LOW-BAY OR HIGH-BAY LIGHT FIXTURE, OF DEVICE
LETTER INDICATES TYPE G - GROUND FAULT
RECESSED DOWNLIGHT, LETTER INDICATES TYPE
INTERRUPTER TYPE
IG - ISOLATED GROUND C
RECESSED WALLWASH FIXTURE, LETTER INDICATES TYPE WP - WEATHER-PROOF GROUND FAULT
INTERRUPTER TYPE
WALL MOUNTED LIGHT FIXTURE, LETTER INDICATES TYPE
<l TELEPHONE/DATA OUTLET, MOUNTED 18" ABOVE FINISHED
CEILING FAN, LETTER INDICATES TYPE FLOOR TO THE CENTER OF DEVICE WITH 314" CONDUIT STUBBED
OUT TO ABOVE ACCESSIBLE CEILING
PENDANT LIGHT FIXTURE, LETTER INDICATES TYPE
<:J TELEPHONE/DATA OUTLET, MOUNTED 6" ABOVE TOP OF COUNTER
CHANDALIER LIGHT FIXTURE, LETTER INDICATES TYPE TO THE CENTER OF DEVICE WITH 3/4" CONDUIT STUBBED OUT
TO ABOVE ACCESSIBLE CEILING
EXIT LIGHT FIXTURE WITH INTEGRAL BATTERY PACK,
� CABLE TV OUTLET, MOUNTED 18" ABOVE FINISHED FLOOR TO ARROWS INDICATE DIRECTION, LETTER INDICATES TYPE
THE CENTER OF DEVICE WITH 314" CONDUIT STUBBED OUT
COMBINATINON EXIT/EMERGENCY LIGHT FIXTURE WITH TO ABOVE ACCESSIBLE CEILING
BATTERY PACK, LETTER INDICATES TYPE
� CABLE TV OUTLET, MOUNTED 6" ABOVE TOP OF COUNTER TO
EMERGENCY LIGHT FIXTURE WITH BATTERY PACK, THE CENTER OF DEVICE WITH 3/4" CONDUIT STUBBED OUT
LETTER INDICATES TYPE TO ABOVE ACCESSIBLE CEILING
EQUIPMENT CONNECTION !DI FLOOR MOUNTED RECEPTACLE WITH BRASS COVER PLATE
C
NON-FUSED DISCONNECT, SIZE AMPERAGE AND NUMBER IZSI FLOOR MOUNTED TELEPHONE OUTLET WITH BRASS COVER PLATE OF POLES IN ACCORDANCE WITH THE CIRCUIT & 3/4" CONDUIT STUBBED OUT TO ABOVE ACCESSIBLE CEILING OVERCURRENT PROTECTIVE DEVICE Iii FLOOR MOUNTED DATA OUTLET WITH BRASS COVER PLATE & 314" FUSED DISCONNECT, SIZE AMPERAGE AND NUMBER OF CONDUIT STUBBED OUT TO ABOVE ACCESSIBLE CEILING
POLES IN ACCORDANCE WITH THE CIRCUIT OVERCURRENT
0il FLOOR MOUNTED CABLE TV OUTLET WITH BRASS COVER PLATE PROTECTIVE DEVICE & 3/4" CONDUIT STUBBED OUT TO ABOVE ACCESSIBLE CEILING
COMBINATION STARTER/DISCONNECT, SIZE AMPERAGE
0) THERMOSTAT OUTLET BOX, MOUNTED 46" ABOVE FINISHEDAND NUMBER OF POLES IN ACCORDANCE WITH THE CIRCUIT OVERCURRENT PROTECTIVE DEVICE FLOOR TO THE CENTER OF DEVICE WITH 112" CONDUIT STUBBED
OUT TO ABOVE ACCESSIBLE CEILING
HOMERUN TO PANELBOARD - ARROW(S) INDICATE
NUMBER OF CIRCUITS. SUBSCRIPT DENOTES
PANELBOARD AND CIRCUIT NUMBER(S)
l
15. SCHEDULE POWER OUTAGES TO AVOID INTERFERENCE WITH THE
OWNER'S ACTIVITIES. OBTAIN APPROVAL FROM OWNER AT LEAST
THIRTY (301 DAYS PRIOR TO THE REQUESTED OUTAGE. IF REQUIRED BY
OWNER, P�OVIDE A SCHEDULE SHOWING SEQUENCE AND DURATION OF
ALL ACTIVITIES DURING THE REQUESTED OUTAGE.
CONSULTANT CONSULTANT CONSULTANT CONSULTANT CONSULTANT CONSULTANT A/E OF RECORD
�VY R&R rJ Jl&A • erra Kimley>>>Horn V m p
ARCHITE:CTURE:
John Gallup & Associates, U.C C, zc,,� KIMl.[T-H:)AK �so �s.s«:"' TI:S. .. �.
Construction 322.5 Shallowford Rd NE 1053 TENTH AVENUE "'31 6 '>ll'U"T, s..,;r 600. S0.'1 DIEOO. LANDSCAPE
CJ. �.llOI � �19➔2l4�!1"11
ARCHITECTS
Suite830 SAN DIEGO, CA 92101 """"·'IJl,llrl'~Hll'lH.COII Marietta, GA 3oo62
PHONE 619.23il.3611 Services, Inc.
462 Stevens Avenue. Suite 107 770-321-4040
Solana Be<1ch, CA 92075-2042 www.davyarchitecture.com Phone: 619.294.8484 website: www.vdla.us
12 lj L I I"
STAMP
!'.,,,,,,,, ._.,,. 'c- OF 1': 11
.. -..._,..: ........... �-t: •, ,:,:,,,/ * ·-.:1�',- *:' \* � r"*: ".*if. ,,. ............................. �
"' LEE K. PHILLIPS ;,�--·····························"" fl:�� : "'
�,t ..... ��i ll
;t:.
€ ••�GIST
'iS',s, •·•·• . • l11{0N
3./11/: {
Drawing Title
Office of ELECTRICAL GENERAL NOTES Construction AND SYMBOL LEGEND and Facilities Management Approved Project Director
VA
U.S. Department of Veterans Affairs
'6 11
BID DOCUMENT
Phase: Project Title Project Number
892PC2037.23
PHASE 2 DEVELOPMENT
I Building Number
I Approved Project Director Location Miramar National Cemetery Drawing Number
5795 Nobel Drive, San Diego, CA 92122 E.101Date Checked
February 22, 2021 LKP Dwg. 215 of 243 le 19
14129 Cross-Out
C:
D
E
F
Revision Date
VA FORM 08 - 6231 11
CONSULTANT
erra p
CONSULTANT CONSULTANT
�VY•
V
ARCHITE:CTURE:
() 1053 TENTH AVENUE
SAN DIEGO, CA 92101
PHONE 619.23il.3611 www.davyarchitecture.com
CONSULTANT CONSULTANT CONSULTANT A/E OF RECORD
R&R rJ Jl&A Kimley>>>Horn m John Gallup & Associates, U.C C, zc,,� KIMl.[T-H:)AK �so �s.s«:"' TI:S. .. �.
Construction 322.5 Shallowford Rd NE "'31 6 '>ll'U"T, s..,;r 600. S0.'1 DIEOO. LANDSCAPE
CJ. �.llOI � �19➔2l4�!1"11
ARCHITECTS
Suite830 """"·'IJl,llrl'~Hll'lH.COII Marietta, GA 3oo6:i.
Services, Inc.
462 Stevens Avenue. Suite 107 770-321-4040
Solana Be<1ch, CA 92075-2042
Phone: 619.294.8484 website: www.vdla.us
L I
CJ I
LIGHTING FIXTURE SCHEDULE
TYPE DESCRIPTION MOUNTING VOLTAGE OUTPUT
A1 2' x 4' LED TROFFER, EDGE LIT FLAT PANEL, MATTE WHITE RECESSED 120/2771/ 3500K
LENS, 0-10V DIMMING 6,400 LUMEN
A2 2' x 4' LED TROFFER, EDGE LIT FLAT PANEL, MATTE WHITE RECESSED 120/2771/ 3500K
LENS, 0-10V DIMMING 3,300 LUMEN$
4FT LED SUSPENDED - MATCH APPEARANCE OF EXISTING 3500K B1 SUSPENDED FLUORESCENT LIGHT FIXTURE LOCATED IN SUSPENDED 120/2771/
OPERATION CENTER 5,000 LUMEN
C2 2FT LED STRIP, ROUND FULL FROST LENS, WIDE SURFACE 120/2771/ 5000K
DISTRIBUTION, 0-10V DIMMING 2,100 LUMENS
C4 4FT LED STRIP, ROUND FULL FROST LENS, WIDE SURFACE 120/2771/ 5000K
DISTRIBUTION, 0-10V DIMMING 2,900 LUMENS
cs SFT LED STRIP, FULL FROST LENS, WIDE DISTRIBUTION, 0-1 0V SURFACE 120/2771/ 5000K
DIMMING, INTERGRAL OCCUPANCY SENSOR 4,200 LUMEN$
6" ROUND LED DOWN LIGHT WITH BAR HANGERS, SPECULAR 3500K D1 CLEAR ALZAK REFLECTOR, 45 DEGREE BEAM ANGLE, SELF RECESSED 120/2771/ 3,000 LUMENS FLANGED, 0-10V DIMMING TO 1%
6" ROUND LED DOWNLIGHT WITH BAR HANGERS,SPECULAR 4000K D2 CLEAR ALZAK REFLECTOR, 45 DEGREE BEAM ANGLE, SELF RECESSED 120/2771/ 5,000 LUMEN$ FLANGED, 0-10V DIMMING TO 1%
H1 EXISTING HIGH BAY FIXTURE TO BE RELOCATED PENDANT 120/2771/
U1 1FT LED UNDERCOUNTER LIGHT, 0-10V DIMMING SURFACE 120/2771/ 3500K
S00 LUMENS
U3 3FT LED UNDERCOUNTER LIGHT, 0-10V DIMMING SURFACE 120/2771/ 3500K
2,500 LUMENS
U4 4FT LED UNDERCOUNTER LIGHT, 0-10V DIMMING SURFACE 120/2771/ 3500K
4,000 LUMEN$
W1 WALLPACK, LED, CUTOFF, TYPE IV OPTICS, COLOR TO BE SURFACE 120/2771/ 4000K
SELECTED BY OWNER'S REPRESENTATIVE 7,500 LUMEN$
EXIT LIGHT, LED, DIECAST ALUMINUM HOUSING, BLACK WITH
X1 BRUSHED ALUMINUM FACE, RED LETTERING, NICKEL-CADMIUM SURFACE 120/2771/ LED
BATTERY, SINGLE FACE
GENERAL NOTES:
1. NO LIGHT FIXTURE SUBSTITUTIONS WILL BE ACCEPTED WITHOUT PRIOR APPROVAL.
2. TYPES SHOWN WITH AN "E" SUFFIX CONTAIN AN INTEGRAL OR REMOTE BATTERY BACK FOR EMERGENCY LIGHTING.
3. TYPES SHOWN WITH AN "N" SUFFIX SHALL BE NIGHT LIGHTING ON AN UNSWITCHED CIRCUIT.
STAMP
!'.,,,,,,,, ._.,,. 'c- OF 1': 11
.. -..._,..: ........... �-t: •, ,:,:,,,/ * ·-.:1�',- *:' \* � r"*: ".*if.,,. ............................. �
"' LEE K. PHILLIPS ;,�--·····························""
fl:�� : "'
�,t ..... ��i ll
;t:.
€ ••�GIST
'iS',s, •·•·• . • l11{0N
3./11/: {
Drawing Title
Office of LIGHTING FIXTURE SCHEDULE Construction and Facilities Management Approved Project Director
VA
U.S. Department of Veterans Affairs
MANUFACTURER& "SERIES"
METALUX "24FP"
METALUX "22FP"
METALUX "SNLED"
METALUX "SNLED"
METALUX "SNLED"
PORTFOLIO "LD4B"
PORTFOLIO "LD4B"
FAIL-SAFE "UCL"
FAIL-SAFE "UCL"
FAIL-SAFE "UCL"
LUMARK "AXCL"
SURE-LITES "CX"
Phase:
Approved Project Director tl 9
NOTES
A
INSTALL NEW LAMPS WITH 5000K COLOR
TEMPERATURE
C
C l f
BID DOCUMENT
Project Title Project Number
892PC2037.23
PHASE 2 DEVELOPMENT
I Building Number
I Location Miramar National Cemetery Drawing Number
5795 Nobel Drive, San Diego, CA92122 E.102Date Checked
February 22, 2021 LKP Dwg. 216 of 243 p
C:
D
E
F
Revision Date
VA FORM 08 - 6231 11
MENS
RESTROOM
I A2021
COMPANIOJII
RESTROOM
I A2031
WOMENS
RESTROOM
I A2041
CONSULTANT
erra
STORAGE
1 A207 ----, _J
H.A.C.
A201i
� I
I f---l
1\
STORAGE
A205
BREEZE
WAY
I A2001
D
I I
D
COVERED
ENTRY
I A1001
-========:i I I
RECEPTION
I A101 I
L
CONFERENCE
I A1021
I
I
AD2-4
DI tECTOR
A105 j
D]
D
I
CJ
B1
ASST.
DIRECTO
I A1141 - B1
1=1 D
- B1
BUDGET
OFFICE
A113
- B1
AD2-2 I
n
OPERATION
CENTER
A1061
I ,.JJ
STORAG:
I A1071
BREAK
ROOM
I A108
I I
I
RESTROOM
I A1091
RESTROOM
A110 tl
ELEC
A1121
GENERAL NOTES
1. REFER TO ARCHITECTURAL PLANS TO DETERMINE AREAS OF
DEMOLITION. REMOVE ALL EXISTING ELECTRICAL EQUIPMENT
IN AREAS OF DEMOLITION. REMOVE ALL EXISTING BRANCH
CIRCUIT CONDUIT AND CONDUCTORS THAT PREVIOUSLY
SERVED LIGHT FIXTURES, RECEPTACLES AND EQUIPMENT
REMOVED DURING DEMOLITION. ALL CONDUIT AND
CONDUCTORS SHALL BE REMOVED BACK TO THE PANELBOARD
THAT THEY ARE SERVED FROM.
2. REFER TO REFLECTED CEILING PLAN ON ARCHITECTURAL
DRAWINGS FOR EXACT LOCATIONS OF CEILING MOUNTED
INTERIOR LIGHT FIXTURES. REFER TO ELEVATIONS ON
ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF
INTERIOR AND EXTERIOR WALL MOUNTED LIGHT FIXTURES.
3. CONNECT LIGHT FIXTURE TYPES "X1" AND THOSE WITH AN "E"
SUFFIX TO CIRCUIT AD2-42 UNLESS SHOWN OTHERWISE.
PLAN NOTES
PRIOR TO INSTALLATION VERIFY THE EXACT LOCATION AND
CONNECTION REQUIREMENTS FOR ALL EQUIPMENT DESIGNATED BY
PLAN NOTES.
1. NEW PANEL "AD2".
2. CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT.
3. EXISTING LIGHT FIXTURE TO BE RELOCATED.
4. EXISTING LIGHT FIXTURE TO REMAIN.
-� �i------ - -;:===-==-=;.3
CORRIDOR (D I
( ---------- =�------- :;=.--------..,1 "" A
--c' _ .. 11
1,..I ______ �- ---------- :.=..-----------,_,..,_:.l::-,.,,.-----cJi, x1' - --------
L �--\\
4 © © © © © 7J1E 'L 7)18
, 1_1 - r2\
2E
\ JL AD2-6) '' '_' '' 'L ' L- '' L '' '-[_ I
" D --
1_1 ��====2c. �-
;�:��:��� o � _/ -@ -@ - B1 i:�£ � B1 - B1 // C FFIC E
A103 - I .., I A2 •• I D
B1 B1 B1 B1
'-----I A2
=:J ======;;;;;i11 IJ J IJ I
'l l
�J
II
'I' I' ))_
II I
======;;;;i111
CONSULTANT
•�VY
ARCHITE:CTURE:
1053 TENTH AVENUE
SAN DIEGO, CA 92101
PHONE 619.23il.3611 www.davyarchitecture.com
CD ADMINISTRATION BLDG. - FLOOR PLAN - LIGHTING
1/4" = 1'-0"
CONSULTANT CONSULTANT CONSULTANT
V
Kimley>>>Horn
C, zc,,� KIMl.[T-H:)AK �so �s.s«:"' TI:S. .. �.
"'31 6 '>ll'U"T, s..,;r 600. S0.'1 DIEOO.
CJ. �.llOI � �19➔2l4-!1"11 """"-'IJl,llrl'-ltll'lH.COII
R&R Construction
Services, Inc.
L I
CONSULTANT
LANDSCAPE
ARCHITECTS
462 Stevens Avenue. Suite 107 Solana Be<1ch, CA 92075-2042 Phone: 619.294.8484 website: www.vdla.us
A/E OF RECORD
Jl&A John Gallup & Associates, U.C
322.5 Shallowford Rd NE
Suite830 Marietta, GA 3oo62 770-321-4040
STAMP
_··;c,,c-. C. 'CC,-.
Office of Construction and Facilities Management
, IA U.S. Department Vft ofVeteransAffairs
I
Drawing Title Phase:
ADMINISTRATION BUILDING
LIGHTING FLOOR PLAN
Approved Project Director Approved Project Director
11 le
,_ - : ._7 -_-. -.-.-0
I
Project Title
PHASE 2 DEVELOPMENT
Location Miramar National Cemetery 5795 Nobel Drive, San Diego, CA92122
I
Date Checked
February 22, 2021 LKP
1/4"•1'-CI"
BID DOCUMENT
Project Number
892PC2037.23
I Building Number
I Drawing Number
AA.E201
Dwg. 217 of 243
A
C
C l f
C:
D
E
F
Revision Date
VA FORM 08 - 6231 11
MENS
RESTROOM
I A202
COMPANIOJII
RESTROOM
I A203
WOMENS
RESTROOM
I A204
CONSULTANT
ra p
STORAGE
1 A207 ----
�-A>·]
H.A.C.
A201i
� I l
1\
STORAG
A205
BREEZE
WAY
I A200
D
I I l,-
D
COVERED
ENTRY
I A100
RECEPTION
I A101 I
L
I�
CONFERENCE
I A102
CD ADMINISTRATION BLDG. - FLOOR PLAN - POWER
1/4" = 1'-0"
CONSULTANT CONSULTANT CONSULTANT CONSULTANT
VY
ARCHITE:CTURE:
1053 TENTH AVENUE
SAN DIEGO, CA 92101
PHONE 619.23il.3611 www.davyarchitecture.com
Kimley>>>Horn C, zc,,� KIMl.[T-H:)AK �so �s.s«: ... TI:S. .. �.
"'31 6 '>ll'U"T, s..,;r 600. S0.'1 DIEOO.
CJ. �.llOI � �19➔2l4�!1"11
""""·'IJl,llrl'~Hll'lH.COII
R&R Construction
Services, Inc.
L I
PANELAD2
208/120 VOLT, 3 PHASE, 4 WIRE
10 KAIC SYMMETRICAL
LOAD SERVED
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
SPARE
RECEPTACLES
RECEPTACLES
RECEPTACLES
SPARE
MODULAR FURNITURE
MODULAR FURNITURE
MODULAR FURNITURE
MODULAR FURNITURE
MODULAR FURNITURE
MODULAR FURNITURE
RECEPTACLES
FAN COIL UNIT
FAN COIL UNIT
PHASE A CONNECTED KVA
PHASE B CONNECTED KVA
PHASE C CONNECTED KVA
TOTAL CONNECTED KVA
ESTIMATED DEMAND KVA
ESTIMATED DEMAND AMPS
AD2-1
<I
100 AMPMLO
PHASE CKTBKR
LOAD # AMP P
800 1 20 1
800 3 20 1 800 5 20 1
1,000 7 20 1 400 9 20 1
11 20 1
400 13 20 1 400 15 20 1
200 17 20 1 1,000 19 20 1 1,000 21 20 1 1,000 23 20 1 1,000 25 20 1 1,000 27 20 1 1,000 29 20 1
31 20 1 1,000 33 20 1
800 35 20 .
800 37 . 2 1,100 39 20 .
1,100 41 . 2
7.0
7.9
8.1
23.0
21.8
60.6
ASST.
CJ
CKTBKR
AMP p #
A 20 1 2 B 20 1 4
C 20 1 6 A 20 1 8 B 20 1 10 C 20 1 12 A 20 1 14 B 20 1 16 C 20 1 18 A 20 1 20 B 20 1 22 C 20 1 24 A 20 1 26 B 20 1 28
C 20 1 30 A 20 1 32 B 20 1 34 C 20 1 36 A 20 1 38 B 20 . 40 C - 2 42
I>
DIRECTOR
A105
DIRECTOR
<I
I
L
I A114 j @ l=1
BUDGET
I>…