The file's text, extracted by GovTribe without its formatting.
MILITARY SEALIFT COMMAND
MSC
S P E C I F I C A T I O N S
FOR
USNS Salvor (T-ARS -52)
ABS ID No.: 85172848
SSU SN26-005
(APRIL 20 THRU JUNE 18, 2026)
MID TERM AVAILABILITY (ANNUAL INSPECTION)
PRINCIPAL DIMENSIONS
LENGTH.......................................255 ft 00 in
BREADTH....................................51 ft 00 in.
FULL LOAD WL.........................18 ft 00in ABL
GROSS TONNAGE…………….3300 TONS
MAXIMUM DISPLACEMENT...3180.33 TONS
THIS SPECIFICATION CONSISTS OF THE FOLLOWING PAGES
INDEX..............................................PAGES 2 THRU 5
LIST OF RFERENCES...................PAGES 5 THRU 20
LIST OF GFM.................................PAGES 21THRU 35
WORK ITEMS..…………………...PAGES XX THRU XXX
MSC Corrective Maintenance
Engineering Report
USNS SALVOR
(TARS 52)
SN26-005
2026-04-20 - ROH/DD
WORK ITEM INDEX REPORT
| Item Number |
| Title |
| Category |
| SECTION 0000 |
| GENERAL SERVICES AND REQUIREMENTS |
| 0001 |
| TARS-SWI-SCOPE GENERAL REQUIREMENTS AND |
| NSP |
| 0002 |
| TARS-SWI-TECHNICAL AND MANUFACTURERS |
| NSP |
| 0003 |
| TARS-SWI-APPROACH BERTHING AND MOORING |
| NSP |
| 0004 |
| TARS-SWI-TESTING AND QUALITY ASSURANCE |
| NSP |
| 0005 |
| TARS-SWI-ELECTRICAL SAFETY PROCEDURE |
| NSP |
| 0006 |
| TARS-SWI-HEAVY WEATHER PLAN |
| NSP |
| 0010 |
| TARS-SWI-FURNISH OFFICE FOR OVERHAUL |
| A |
| 0011 |
| TARS-SWI-GENERAL SERVICES FOR SHIP |
| A |
| 0012 |
| TARS-SWI-INFORMATION TECHNOLOGY SERVICES |
| A |
| 0013 |
| TARS-SWI-INTEGRATED PROJECT PLANNING AND |
| A |
| 0014 |
| TARS-SWI-WEIGHT AND MOMENT REPORT |
| A |
| 0016 |
| TARS-SWI-FIRE PROTECTION AND SHIPS SAFETY |
| A |
| 0017 |
| TARS-SWI-HANDLING SHIPS STORES |
| A |
| 0018 |
| TARS-SWI-DELIVERY AND REDELIVERY OF THE VESSEL |
| A |
| 0019 |
| TARS-SWI-SHIPBOARD ACCESS AND SECURITY |
| A |
| 0020 |
| TARS-SWI-GAS FREE CERTIFICATES |
| A |
| 0021 |
| TARS-SWI-CLEAN AND GAS FREE TANKS VOIDS |
| A |
| 0022 |
| TARS-SWI-MACHINERY SPACE TURN-OVER DOCK TRIALS |
| A |
| 0023 |
| TARS-SWI-HAZARDOUS WASTE DISPOSAL AT A |
| A |
| 0030 |
| TARS-SWI-CONTINUATION OF SERVICES |
| B |
| 0040 |
| TARS-SWI-OCONUS FORCE PROTECTION |
| A |
| SECTION 0100 |
| HULL AND STRUCTURAL |
| 0101 |
| TOWING ROPE TEMP STOWAGE |
| A |
| 0102 |
| REPLACE BRIDGE WINDOWS |
| A |
| 0103 |
| SEWAGE HEADER PIPE RENEWAL (VR24-009) |
| A |
| 0104 |
| MISCELLANEOUS STEEL REPAIR |
| A |
| 0105 |
| TANK VENTS PRESERVAITON AND INSPECTION |
| A |
| 0106 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| A |
| 0107 |
| FUEL SERVICE TANK 3-38-2 FILL LINE PIPE RENEW |
| A |
| 0108 |
| JOINER DOORS RENEWAL |
| A |
| 0109 |
| EXTERIOR VENTILATION FLANGE RENEWAL VR24-0036 |
| A |
| 0110 |
| TANKS SOUNDING PIPE RENEWAL |
| A |
| 0111 |
| TRASH ROOM BULKHEAD STEEL RENEWAL VR25-0024 |
| A |
| 0112 |
| FAN ROOM (01-69-1) BULKHEAD STEEL RENEWAL |
| A |
| 0113 |
| AFT SALVAGE STEEL RENEWAL |
| A |
| 0114 |
| WATERTIGHT DOORS OVERHAUL (55" X 81") |
| A |
| 0115 |
| STBD BRIDGE WING BEAMS REPAIR (VR25-0026) |
| A |
| 0116 |
| 01-68-1 FAN ROOM DECK DRAIN REPAIR (VR25-0023) |
| A |
| 0117 |
| PORT & STBD PIPE ROPE RAILS RENEWAL (VR25-0032) |
| A |
| 0118 |
| MAIN MAST PRESERVATION (VR25-0035) |
| A |
| 0119 |
| STRAINERS FOUNDATION RENEWAL |
| A |
| 0120 |
| LIGHTNING ARRESTER VR25-0021 |
| A |
| 0121 |
| #4 FIREPUMP FOUNDATION REPAIR VR25-0054 |
| A |
| 0122 |
| ASW CUNI PIPE RENEWAL VR25-0056 |
| A |
| 0123 |
| CLEANING GEAR LOCKER BULKHEAD REPAIR VR25-0048 |
| A |
| 0124 |
| FGR TRUNK HOLE REPAIR VR25-0029 |
| A |
| 0125 |
| NATURAL DUCT REPAIR AND PRESERVAITON |
| A |
| 0126 |
| AMR UPPER PORT STIFFNERS RENEW VR25-0057 |
| A |
| 0131 |
| TARS-CSI-CABLE PENETRATION INSPECTION (5 YR) |
| A |
| 0153 |
| TARS-CCSI-ABS INTERMEDIATE SURVEY - TANK |
| A |
| 0165 |
| TARS-CCSI-BILGE PRESERVATION (10 YR) |
| A |
| 0180 |
| TARS-CCSI-MOORING STRUCTURE PRESERVATION (10 YR) |
| A |
| 0181 |
| TARS-CCSI-TOPSIDE CRADLES AND FOUNDATIONS |
| A |
| 0183 |
| TARS-CCSI-VOID, COFFERDAM, PIPING TUNNELS |
| A |
| 0187 |
| TARS-CCSI-FAN ROOM PRESERVATION (10 YR) |
| A |
| SECTION 0200 |
| PROPULSION MACHINERY |
| 0251 |
| TARS-CCSI-WOODWARD GOVERNORS (20K HRS) (SCSI) |
| A |
| 0254 |
| TARS-CSI-BEARING INSPECTION (5 YR) (SCSI) |
| A |
| 0287 |
| TARS-CSI-AUTOMATION AND PROPULSION CONTROL |
| A |
| 0301 |
| REFURBISH FGR VENT CONTROLLER |
| A |
| 0302 |
| FAN DUCTING REPAIR (1-52-1-Q) VR25-0020 |
| A |
| 0303 |
| VANE AXIAL FANS OVERHAUL |
| A |
| 0304 |
| 1SG FIELD FLASH CONTROL |
| A |
| 0305 |
| 2SGA GENERATOR HEATER REPLACEMENT VR25-0036 |
| A |
| 0351 |
| TARS-CCSI-SWITCHBOARD CLEANING (2.5 YR) |
| A |
| 0352 |
| TARS-CCSI-LOAD CENTER CLEANING (2.5 YR) |
| A |
| 0353 |
| TARS-CCSI-THERMOGRAPHIC SURVEY (1 YR) |
| A |
| 0354 |
| TARS-CCSI-GENERATOR CLEANING AND INSPECTION (5 |
| A |
| SECTION 0400 |
| COMMUNICATION AND NAVIGATION |
| 0451 |
| TARS-CCSI-ANNUAL RADAR SERVICE |
| A |
| 0452 |
| TARS-CCSI-ANNUAL ECDIS SERVICE (SCSI) |
| A |
| 0453 |
| TARS-CCSI-ANNUAL GYRO SYSTEM PM |
| A |
| 0454 |
| TARS-CCSI-ANNUAL VDR RECERTIFICATION |
| A |
| 0455 |
| TARS-CCSI-ANNUAL RADIO COMMUNICATION EQUIPMENT |
| A |
| 0456 |
| TARS-CCSI-MAGNETIC COMPASS SERVICE (2 YR) |
| A |
| 0458 |
| TARS-CCSI-ANTENNA MAINTENANCE (2.5 YR) |
| A |
| 0459 |
| TARS-CCSI-ECHO SOUNDER SERVICE (2.5 YR) |
| A |
| 0460 |
| TARS-CCSI-ANNUAL INSPECTION OF MANUALLY |
| A |
| 0490 |
| TARS-CSI-SPEED LOG SERVICING (5 YR) |
| A |
| 0492 |
| TARS-CSI- ELECTRONIC TEST EQUIPMENT (GPETE) |
| A |
| SECTION 0500 |
| AUXILIARY MACHINERY |
| 0502 |
| OVERHAUL FIRE MONITORS VR25-0054 |
| A |
| 0503 |
| AUX FIRE PUMPS OVERHAUL (ABS 5 YRS) |
| A |
| 0504 |
| ENGINE JACKET FLUSH VR25-0038 |
| A |
| 0546 |
| TARS-CSI-AIR REGULATING VALVE REFURBISHMENT (2.5 |
| A |
| 0556 |
| TARS_CCSI_INSPECT DECK CRANES (1 YR) |
| A |
| 0561C |
| TARS-CCSI-GAUGE CALIBRATION (5 YR) |
| A |
| 0562 |
| TARS-CCSI-SCBA ANNUAL INSPECTION |
| A |
| 0563B |
| TARS-CCSI-SCBA COMPRESSOR AND FILLING STATION |
| A |
| 0565A |
| TARS-CCSI-FIXED GAS FIREFIGHTING SYSTEM INSPECTION |
| A |
| 0567A |
| TARS-CCSI-FIXED FOAM FIREFIGHTING SYSTEM |
| A |
| 0569 |
| TARS-CCSI-FIRE AND SMOKE DETECTION AND ALARM |
| A |
| 0570 |
| TARS-CCSI-PORTABLE FIRE EXTINGUISHER SERVICE (1 YR) |
| A |
| 0571 |
| TARS-CCSI-FIRE AND SMOKE DAMPER SERVICE (1 YR) |
| A |
| 0572 |
| TARS-CCSI-DEEP FAT FRYER AND RANGE HOOD FIRE |
| A |
| 0573 |
| TARS-CCSI-FIRE STATIONS AND HOSES (1 YR) |
| A |
| 0574A |
| TARS-CCSI-FIRE DOORS AND SHUTTERS (1 YR) |
| A |
| 0580 |
| TARS-CSI-REFRIGERATION PLANTS SERVICING AND |
| A |
| 0587 |
| TARS-CSI-OILY WATER SEPARATOR SYSTEM SERVICING (5 |
| A |
| 0588 |
| TARS-CSI-OIL CONTENT MONITOR CALIBRATION (2 YR) |
| A |
| 0592 |
| TARS-CSI-SS DIESEL ENGINE - MINOR OVERHAUL (10K |
| A |
| 0599 |
| TARS-CSI-LP AIR COMPRESSOR MINOR OVERHAUL (4K |
| A |
| SECTION 0600 |
| HABITABILITY OUTFITTING AND FURNISHINGS |
| 0602 |
| MEDICAL REEFER RENEWAL VR25-0011 |
| A |
| 0604 |
| WORKBOAT DAVIT SERVICE |
| A |
| 0606 |
| SEWAGE TANK PRESERVATION |
| A |
| 0607 |
| FREEZER DOOR RENEWAL VR23-0004 |
| A |
| 0608 |
| PRC DECK RECOAT AND RESEAL |
| A |
| 0609 |
| ALLIED DAVIT WINCH RENEWAL |
| A |
| 0653A |
| TARS-CCSI-ANNUAL RESCUE BOAT INSPECTION |
| A |
| 0653B |
| TARS-CCSI-ANNUAL RESCUE BOAT DAVIT INSPECTION |
| A |
| 0656 |
| TARS-CCSI-ANNUAL LIFE RAFT CERTIFICATION |
| A |
| 0673 |
| TARS-CCSI-READY SERVICE LOCKER OVERHAUL (5 YR) |
| A |
| 0801 |
| #1 AC CHILLER CONDENSER TUBE SHEET VR25-0034 |
| A |
| 0802 |
| AC CHILLER ECONIMIZER RENEWAL VR25-0057 |
| A |
| 0853 |
| TARS-CCSI-ACCOMMODATION VENT SYSTEM CLEANING (5 |
| A |
| 0881 |
| TARS-CSI-AC CHILLER SERVICING (1 YR) |
| A |
| 0901 |
| TARS-CCSI-DRYDOCKING AND UNDOCKING THE VESSEL |
| A |
| 0902 |
| FAIRWATER AND BEARINGS INSPECTION |
| A |
| 0903 |
| OVERHAUL CPP OD-BOX |
| A |
| 0904 |
| SEACHEST VENTS FLUSHING |
| A |
| 0905 |
| FIRE PUMP VALVES RENEWAL |
| A |
| 0906 |
| SERVICE BOW THRUSTER |
| A |
| 0907 |
| RUDDER INSPECTION, SEALS AND BEARINGS RENEWAL |
| A |
| 0909 |
| SEA VALVES OVERHAUL |
| A |
| 0910 |
| STERN TUBE BARRELS EXTERNAL SURFACE |
| A |
| 0951 |
| TARS-CCSI-DRYDOCKING AND UNDOCKING THE VESSEL |
| B |
| 0953 |
| TARS-CCSI-ANCHORS, CHAINS AND LOCKERS-FULL BLAST |
| A |
| 0957 |
| TARS-CCSI-PROPELLER CLEAN AND POLISH - ON DOCK (2.5 |
| A |
| 0959 |
| TARS-CCSI-UNDERWATER HULL CLEANING AND PAINTING |
| A |
| 0962 |
| TARS-CCSI-CATHODIC PROTECTION SYSTEM (5 YR) |
| A |
| 0963 |
| TARS-CCSI-SEA CHEST MARINE GROWTH PREVENTION |
| A |
| 0966 |
| TARS-CCSI-SHAFT ALIGNMENT AND BEARING REACTION |
| A |
| 0970 |
| TARS-CCSI-FREEBOARD PRESERVATION - FULL BLAST (10 |
| A |
| 0984 |
| TARS-CSI-HULL ZINC REPLACEMENT (5 YR) |
| A |
| 0986 |
| TARS_CSI_STERN TUBE SEAL MINOR OVERHAUL |
| A |
| 0992 |
| TARS-CSI-CPP SYSTEM SERVICE - INTERMEDIATE |
| A |
DRAWING AND REFERENCE INDEX
USNS SALVOR (T-ARS-52)
WORK ITEM# Nomenclature
0001_N_INTENT SCOPE GEN REQUIREMENTS DEFINITIONS REV MAY 16
2.1.1 MSC Drawing 803-7081122, Military Sealift Command General Technical Requirements (GTRs)
0002_N_TARS-SWI-TECHNICAL AND MANUFACTURERS REPRESENTATIVE
REFERENCES: None 0003_A_APPROACH, BERTH, AND MOORING REQUIREMENTS REV 08Nov17.
2.1.1 MIL. STD. MIL-C-28628D, of July 1991; Camels.
2.1.2 MIL. STD. MIL-F-29248, of 21 November 1986; Fenders, Marine, Foam Filled, Nettles
2.1.3 MSC Drawing No. 802-5763565, General Arrangement Plan
2.1.4 MSC Drawing No. 5764389, Mooring Arrangement.
2.1.5 DOD Uniform Facilities Criteria, UFC 4-159-03; Moorings
0004_A_ TARS-SWI-TESTING AND QUALITY ASSURANCE
2.0 REFERENCES: None
0005_NSP_ELECTRICAL SAFETY PROCEDURE REQUIREMENTS, REV FEB 14
| 2.1 | MSC Safety Management System Procedure 2.1-004-ALL, Lock-out/Tag-out |
| 2.2 | 29CFR 1910.335 Electrical Safety Related Work Practices; Safeguards for Personnel Protection |
| 2.3 | NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces |
006_NSP_HEAVY WEATHER PLAN, REV FEB 14
2.1.1 MSC Drawing No. 835-8387903, USNS SALVOR Trim and Stability Booklet.
0010_A_TARS-SWI-FURNISH OFFICE FOR OVERHAUL MANAGEMENT TEAM (OMT)
2.1.1. FAR 37.104(d), Personal Services Contracts. This reference is publicly available on the internet using a search engine.
2.1.2. FAR 37.112, Government Use of Private Sector Temporaries. This reference is publicly available on the internet using a search engine.
0011_A_GENERAL SERVICES FOR SHIP, T ARS, REV A OCONUS FEB 15
2.1.1 NAVSEA DWG 801-5763541 Shore Services
2.1.2 NAVSEA DWG 302-5762719 List of Motors and Controllers
2.1.3 MSC Chemical Treatment Handbook
0012_A_TARS-SWI-INFORMATION TECHNOLOGY SERVICES (OCONUS)
2.0 Reference: None
0013_A_TARS-SWI-INTEGRATED PROJECT PLANNING AND PRODUCTION STATUS MONITORING REPORTS
2.0 Reference: None
0015_A_ILS, GFM, REV FEB 14
2.1Department of Defense Security Manual for safeguarding. Classified Information DOD Manual 5220.22-
0016_A_TARS-SWI-FIRE PROTECTION AND SHIPS SAFETY PROGRAM
| 2.1 | National Fire Protection Association 312, Standard for Fire Protection of Vessels During Construction, Repair and Lay-up |
| 2.2 | National Fire Protection Association 51B, Standard for Fire Prevention in Use of Cutting and Welding Processes |
| 2.3 | OSHA Fire Protection while in a shipyard, 29 Code of Federal Regulations (CFR) Part 1915.506, titled “Hazards of fixed extinguishing systems on board vessels and vessel sections” |
| 2.4 | OSHA Confined Space Entry Program, 29 Code of Federal Regulations (CFR) Part 1910.146, titled “Permit-required confined spaces” |
| 2.5 | MSC Drawing No. 085-8195813, Fire Control Plan |
| 2.6 | NAVSEA Drawing No. 521-5763100, Diagram Firemain and Tunneling System |
0017_A_TARS-SWI-HANDLING SHIPS STORES
2.0 Reference: None
0018_A_TARS-SWI-DELIVERY AND REDELIVERY OF THE VESSEL
| 2.1 | NAVMED P-5010-6, Manual of Naval Preventive Medicine, Chapter 6, Water Supply Afloat. |
| 2.2 | MSC Drawing No. 582-5763341, Mooring and Towing Arrangement. |
0019_A_TARS-SWI-SHIPBOARD ACCESS AND SECURITY
| 2.1 | COMSCINST 5530.3 Series, Military Sealift Command (MSC) Shipboard Force Protection (FP) Program |
| 2.2 | NAVSEA Standard Item 009-72 (current revision) |
| 2.3 | MSC Drawing No. 801-5763565, Booklet of General |
0020_A_TARS-SWI-GAS FREE CERTIFICATES
2.0 Reference: None
0021_A_ CLEAN AND GAS FREE TANKS, VOIDS AND COFFERDAMS
2.1.1 Drawing No. 801-5763565, BOOKLET OF GENERAL DRAWINGS, USNS SALVOR (T- ARS)
2.1.2 Drawing No. 085-8387903, USNS SALVOR, Trim & Stability Booklet
0022_A_TARS-SWI-MACHINERY SPACE TURN-OVER DOCK TRIALS AND SEA TRIALS
2.0 Reference: None
0023_A_TARS SWI HAZARDOUS WASTE DISPOSAL AT A CONTRACTOR FACILITY
2.1.1 Resource Conservation and Recovery Act (RCRA) as amended
2.1.2 10 U.S.C. §7311
2.1.3 Applicable Uniform Hazardous Waste Manifest Form
2.1.4 Test Methods for Evaluating Solid Waste, Physical/Chemical Methods; EPA Document, SW-846; the official compendium of analytical and sampling methods that have been evaluated and approved for use in complying with the RCRA regulations.
2.1.5 OPNAVINST 5090.1C
0030_B_TARS-SWI-CONTINUATION OF SERVICES
2.0 Reference: None
0040_A_TARS-SWI-OCONUS FORCE PROTECTION
2.0 Reference: None
0101_A_TOWING ROPE TEMP STOWAGE
2.0 Reference: None
0102_A_REPLACE BRIDGE WINDOWS VR210064
2.1.1 NAVSEA Drawing 5763436 Fixed Lights Window Schedule
2.1.2 NAVSEA Technical Manual S9625-AL-MMM-010 Window, Electrically Heated Deicing.
0103_A_SEWAGE HEADER PIPE RENEWAL (VR24-009)
2.0 Reference: None
0104_A_MISCELLANEOUS STEEL REPAIR
2.0 Reference: None
0105_A_TANK VENTS PRESERVAITON AND INSPECTION
2.1.1 MSC Drawing 506-5763019, Diagram – Overflows, Air Escapes and Sounding Tubes
0106_A_STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027
| 2.1.1 | Drawing 5762669: Structural ASSY 602 |
| 2.1.2 | Drawing 5762670: Structural ASSY 603 |
| 2.1.3 | MSFSC SWIRR 006: Insulation Repairs |
0107_A_FUEL SERVICE TANK 3-38-2 FILL LINE PIPE RENEW
2.1.1 DRAWING 5763242- DIAGRAM FUEL OIL FILL TRANSFER & PURIFICAITON SYSTEM.
0108_A_JOINER DOORS RENEWAL
| 2.1.1 | DRAWING 5763434: NON-STRUCTURE ACCESS CLOSURES SCHEEDULE. |
| 2.1.2 | DRRAWING 4629248: DOOR JOINER METAL HONECOMB CORE |
0109_A_EXTERIOR VENTILATION FLANGE RENEWAL VR24-0036
2.1.1 NAVSEA DWG 5763065: HVAC-01 Level FR 40-FWD
0110_A_TANKS SOUNDING PIPE RENEWAL
2.1.1 DWG 5763019: DIAGRAM- OVERFLOWS, AIR ESCAPES AND SOUNDING TUBES
0111_A_TRASH ROOM BULKHEAD STEEL RENEWAL VR25-0024
2.0 Reference: None
0112_A_FAN ROOM (01-69-1) BULKHEAD STEEL RENEWAL
2.0 Reference None
0113_A_AFT SALVAGE STEEL RENEWAL
| 2.1.1 | NAVSEA DWG 5762695- HATCH RAMPS | |
| 2.1.2 | NAVSEA DWG 5763476- SALVAGE STRM ARR (INSIDE STOWAGE) | |
| 2.1.3 | NAVSEA DWG 5763401- PORTABLE DAVITS | |
| | 0114_A_WATERTIGHT DOORS OVERHAUL (55_ X 81_) |
2.1.1 NAVSEA Drawing No. 071-5762645, Access and Compartment Main Deck
0115_A_STBD BRIDGE WING BEAMS REPAIR (VR25-0026)
2.1.1 DWG 5762670- Structural ASSY 603
0116_A_01-68-1 FAN ROOM DECK DRAIN REPAIR (VR25-0023)
2.2.1 NAVSEA DWG# 5763139, “PP ARR 02 & 03 LVL DIAGRAM
WEA. DECK DRAINS”.
0117_A_PORT & STBD PIPE ROPE RAILS RENEWAL (VR25-0032)
2.0: Reference: None
0118_A_MAIN MAST PRESERVATION (VR25-0035)
2.1 NAVSEA DWG 100-5762696: Structural Assembly 703 Radar Mast
0119_A_STRAINERS FOUNDATION RENEWAL
2.0 Reference: None
0120_A_LIGHTNING ARRESTER VR25-0021
2.1.1 NAVSEA DWG 5762668 Rev F. Structural Assembly
0121_A_#4 FIREPUMP FOUNDATION REPAIR VR25-0054
2.0 Reference: None
0122_A_ASW CUNI PIPE RENEWAL VR25-0056
2.0 Reference: None
0123_A_CLEANING GEAR LOCKER BULKHEAD REPAIR VR25-0048
2.0 Reference: None
0124_A_FGR TRUNK HOLE REPAIR VR25-0029
2.1.1 DWG 5762661- STRUCTURAL ASSY 402
0125_A_NATRUAL DUCT REPAIR AND PRESERVAITON
2.1.1 NAVSEA DWG# 5763052 HVAC-MAIN DECK FR 40-60
0126_A_AMR UPPER PORT STIFFNERS RENEW VR25-0057
2.20 Reference: None
0131_A_TARS-CSI-CABLE PENETRATION INSPECTION (5 YR)
2.1 MSC Drawing 085-8195813, Fire Control Plan
0153_A_TARS-CCSI-ABS INTERMEDIATE SURVEY - TANK INSPECTION (2.5 YR)
| 2.1.1 | MSC Drawing 801-5763565, Booklet of General Drawings |
| 2.1.2 | NAVSEA Drawing 631-5763437, Painting Schedule |
| 2.1.3 | MSC Drawing 801-5763567, Tank Sounding, Gauging, and Ullage Tables |
| 2.1.4 | ABS Rules for Building and Classing Steel Vessels, Part 7 Survey After Construction |
0165_A_TARS-CCSI-BILGE PRESERVATION (10 YR)
| 2.1 | MSC Drawing No. 801-8387772, Booklet of General Plans |
| 2.2 | Surface Preparation Standard, SSPC-SP-3, Power Tool Cleaning (Available Commercially) |
| 2.3 | Surface Preparation Standard, SSPC-SP-11, Power Tool Cleaning to Bare Metal (Available Commercially) |
| 2.4 | PPG Product Data Sheets, Amercoat 240 |
0180_A_TARS-CCSI-MOORING STRUCTURE PRESERVATION (10 YR)
| 2.1 | MSC Drawing No. 801-5763565, Booklet of General Plans |
| 2.2 | NAVSEA Drawing 582-5763341, Ships Mooring Arrangement and Details |
| 2.3 | Technical Manual S9582-AQ-MMM-010, Two Speed Electric Capstan |
| 2.4 | Surface Preparation Standard, SSPC-SP WJ-2/NACE WJ-2 Waterjet Cleaning of Metals – Very Thorough Cleaning (Available Commercially) |
| 2.5 | Surface Preparation Standard, SSPC-SP10/NACE 2, Near White Metal Blast Cleaning (Available Commercially) |
| 2.6 | Surface Preparation Standard, SSPC-SP11, Power Tool Cleaning to Bare Metal (Available Commercially) |
| 2.7 | Surface Preparation Standard, SSPC-SP1, Solvent Cleaning (Available Commercially) |
| 2.8 | ASTM D4417, Method C, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel |
| 2.9 | Surface Preparation Standard, SSPC-PA2, Measurement of Dry Coating Thickness with Magnetic Gages (Available Commercially) |
| 2.10 | PPG-MSC Paint Handbook |
| 2.11 | PPG Product Data Sheets, Amercoat 240 and Amershield |
0181_A_TARS-CCSI-TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION (10 YR)
| 2.1.1 | MSC Drawing No. 801-5763565, Booklet of General Plans |
| 2.1.2 | Surface Preparation Standard, SSPC-SP WJ-2/NACE WJ-2 Waterjet Cleaning of Metals – Very Thorough Cleaning (Available Commercially) |
| 2.1.3 | Surface Preparation Standard, SSPC-SP10/NACE 2, Near White Metal Blast Cleaning (Available Commercially) |
| 2.1.4 | Surface Preparation Standard, SSPC-SP11, Power Tool Cleaning to Bare Metal (Available Commercially) |
| 2.1.5 | Surface Preparation Standard, SSPC-SP1, Solvent Cleaning (Available Commercially) |
| 2.1.6 | ASTM D4417, Method C, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel |
| 2.1.7 | Surface Preparation Standard, SSPC-PA2, Measurement of Dry Coating Thickness with Magnetic Gages (Available Commercially) |
| 2.1.8 | PPG-MSC Paint Handbook |
| 2.1.9 | PPG Product Data Sheets, Amercoat 240 and Amershield |
0183_A_TARS-CCSI-VOID, COFFERDAM, PIPING TUNNELS PRESERVATION (20 YR)
| 2.1.1 | MSC Drawing No. 801-8387672, General Arrangement Drawing |
| 2.1.2 | NAVSEA Drawing No. 801-5763545, Tank Capacity Curves |
| 2.1.3 | Surface Preparation Standard, SSPC-SP1, Solvent Cleaning (Available Commercially) |
| 2.1.4 | Surface Preparation Standard, SSPC-SP10/NACE No. 2, Near White Blast Cleaning (Available Commercially) |
| 2.1.5 | Surface Preparation Standard, SSPC-SP WJ-2/NACE WJ-2 Waterjet Cleaning of Metals – Very Thorough Cleaning (Available Commercially) |
| 2.1.6 | Surface Preparation Standard, SSPC-SP3, Power Tool Cleaning (Available Commercially) |
| 2.1.7 | ASTM D4417, Method C, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel |
| 2.1.8 | Surface Preparation Standard, SSPC-PA2, Measurement of Dry Coating Thickness with Magnetic Gages (Available Commercially) |
| 2.1.9 | PPG-MSC Handbook |
| 2.1.10 | PPG Product Data Sheets, Amercoat 240 |
0187_A_TARS-CCSI-FAN ROOM PRESERVATION (10 YR)
| 2.1 | MSC Drawing No. 801-8387672, General Arrangement |
| 2.2 | Surface Preparation Standard, SSPC-SP1, Solvent Cleaning (Available Commercially) |
| 2.3 | Surface Preparation Standard, SSPC-SP3, Power Tool Cleaning (Available Commercially) |
| 2.4 | Surface Preparation Standard, SSPC-SP11, Power Tool Cleaning to Bare Metal (Available Commercially) |
| 2.5 | ASTM D4417, Method C, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel |
| 2.6 | Surface Preparation Standard, SSPC-PA2, Measurement of Dry Coating Thickness with Magnetic Gages (Available Commercially) |
0251_A_TARS-CCSI-WOODWARD GOVERNORS (20K HRS) (SCSI)
| 2.1 | NAVSEA Tech Manual No. S9233-BN-MMM-010, Main Propulsion Engines, Caterpillar M/D399B-TA |
| 2.2 | 82340A EGB-Proportional Governor/Actuator with Hydraulic Amplifier Systems |
| 2.3 | S9233-CC-MMC-010 Electronic Control, Woodward Governor, 400 Series |
0254_A_TARS-CSI-BEARING INSPECTION (5 YR) (SCSI)
| 2.1 | NAVSEA Technical Manual S9244-AM-MMC-010, Line shaft Bearing |
| 2.2 | NAVSEA Drawing No. 243-5762716, Arrangement Main Propulsion Shafting |
0287_A_TARS-CSI-AUTOMATION AND PROPULSION CONTROL INSPECTION AND TEST (1 YR)
| 2.1 | T-ARS Periodic Safety Test Procedures |
| 2.2 | MSC Technical Manual TE070-AA-OMA-010, Machinery Control System (MCS) Automation Central Control Station (CCS) |
| 2.3 | MSC Technical Manual T9202-BD-SCM-010, Machinery Control System (MCS) Automation Software |
| 2.4 | 1756-TD001C-EN-E, Control Logix Controller Specifications |
| 2.5 | ABS Rules for Survey after Construction, Part 7 to 7-8-1 |
0301_A_REFURBISH FGR VENT CONTROLLER
2.0 Reference: None
0302_A_FAN DUCTING REPAIR (1-52-1-Q) VR25-0020
| 2.1.1 | NAVSEA DWG 5763052 -HVAC- MAIN DECK FR 40-60 |
| 2.1.2 | SWI# 049 Repair of Vent Fans & Motor. |
0303_A_VANE AXIAL FANS OVERHAUL
| 2.1.1 | DWG 5763065- HVAC 01 LEVEL FR-40 FWD (ASSY 601) |
| 2.1.2 | DWG 5763066- HVAC ARR- 01 LEVEL FR 40-AFT (ASSY 602) |
| 2.1.3 | SWI# 049- Repair of Vent Fans & Motors |
0304_A_1SG FIELD FLASH CONTROL
| 2.1 | S9311-A1-MMM-010: SHIP SERVICE GENERATOR |
| 2.2 | DWG 5762764: SS GENERATOR CONT & IND CABLING DIAGRAM |
0305_A_2SGA GENERATOR HEATER REPLACEMENT VR25-0036
| 2.1.1 | DWG 5762764- SS GENERATOR CONT & IND CABLING DIAGRAM |
| 2.1.2 | DWG 5762765- SS GENERATOR CONT & IND WIRING DIAGRAM |
0306_A_TLI REPLACEMENT
2.0 Reference: None
0351_A_TARS-CCSI-SWITCHBOARD CLEANING (2.5 YR)
| 2.1.1 | NAVSEA Technical Manual, SE681-AR-MMM-010, Vol I, 1S and 2S Switchboards - Chapter 1-5 1S and 2S Switchboards |
| 2.1.2 | NAVSEA Technical Manual, SE681-AR-MMM-020, Vol II, 1S and 2S Switchboards - Chapter 6, 7 and 8 |
| 2.1.3 | NAVSEA Technical Manual, 0362-LP-240-4000, Air Circuit Breakers, Type ACB-1600R/1600 Amp, Navy Type |
| 2.1.4 | NAVSEA Drawing No. 324-6587242, Alongside Power Switchboard Connection Diagram |
| 2.1.5 | NAVSEA Drawing No. 324-6178739, Alongside Power Switchboard Construction and Assembly Details |
| 2.1.6 | NAVSEA Drawing No. 302-5762719, List of Motors and Controllers |
| 2.1.7 | NAVSEA Drawing No. 320-8386968, Ship Service Power and Lighting System One-Line Diagram |
| 2.1.8 | MSFSC SWIRRR 020, Switchboard and Electrical Control Cabinet Survey, Cleaning and Repair |
0352_A_TARS-CCSI-LOAD CENTER CLEANING (2.5 YR)
| 2.1.1 | MSC Drawing No. 320-8386968, Ship Service Power and Lighting System One-Line Diagram |
| 2.1.2 | NAVSEA Drawing No. 302-5762719, List of Motors and Controllers |
| 2.1.3 | MSFSC SWIRRR 020, Switchboard and Electrical Control Cabinet Survey, Cleaning and Repair |
0353_A_TARS-CCSI-THERMOGRAPHIC SURVEY (1 YR)
| 2.1.1 | NAVSEA Drawing No. 320-8386968, Ship Service Power and Lighting System One-Line Diagram |
| 2.1.2 | MSFSC SWIRRR 020, Switchboard and Electrical Control Cabinet Survey, Cleaning and Repair |
| 2.1.3 | ASTM E1934–99a Examining Electrical and Mechanical Equipment with Infrared Thermography. The contractor must obtain and procure this reference as it is copyrighted material. (Available commercially) |
0354_A_TARS-CCSI-GENERATOR CLEANING AND INSPECTION (5 YR) (SCSI)
| 2.1.1 | Tech Manual S9311-A1-MMM-010, Ships Service Diesel Generator |
| 2.1.2 | Tech Manual S9311-A1-MMM-020, Ships Service Diesel Generator |
| 2.1.3 | Tech Manual S9086-KC-STM-010, NSTM Chapter 300 |
| 2.1.4 | IEEE Standard 43-2013 – IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery (Available commercially) |
| 2.1.5 | MSFSC Standard Item 34, Heat Exchanger Cleaning |
0451_A_TARS-CCSI-ANNUAL RADAR SERVICE
| 2.1.1 | Northrop Grumman Tech Manual 659000V1-18, Sperry Marine VisionMaster FT Ship’s Manual Volume 1 (Installation, Servicing and Maintenance |
| 2.1.2 | Northrop Grumman Tech Manual 659000V2-18, Sperry Marine VisionMaster FT Ship’s Manual Volume 2 (Configuraton & Commissioning) |
| 2.1.3 | MSC Dwg. No. 8615219, X-Band & S-Band Installation Block Cabling Diagram |
| 2.1.4 | IMO MSC.192 (79), Adoption of the Revised Performance Standards for RADAR Equipment (Available commercially) |
0452_A_TARS-CCSI-ANNUAL ECDIS SERVICE (SCSI)
| 2.1 | Northrop Grumman Tech Manual 65900012-10, Sperry Marine VisionMaster FT ECDIS User Guide |
| 2.2 | MCC Dwg. No. 426-8615216-ECDIS Installation Block Cabling Diagram |
| 2.3 | MSC Dwg. No. 402-8193787, IMO Approved Radars and ECDIS Installation, EWD and BWD |
0453_A_TARS-CCSI-ANNUAL GYRO SYSTEM PM
| 2.2 | Tech Manual, Sperry Marine NAVIGAT X Mk I Digital Gyrocompass System (T-ARS 52) |
| 2.3 | MSC Drawing No. 406-8391852, Gyrocompass Replacement Electrical Installation (T-ARS 52) |
0454_A_TARS-CCSI-ANNUAL VDR RECERTIFICATION
| 2.1.1 | Tech Manual NW6000-10_2, Installation, Operation, and Maintenance Voyage Data Recorder, Netwave Systems, B.V, Model NW6000 |
| 2.2 | Enclosure: |
| 2.2.1 | ABS Checksheet on SOLAS Surveys – “VDR” and “S-VDR” Radio Technician’s Survey, Rev. 5. |
| 2.2.2 | Mandatory Bridge Alarms |
0455_A_TARS-CCSI-ANNUAL RADIO COMMUNICATION EQUIPMENT RECERTIFICATION
| 2.2.1 | ABS CHECK SHEET FOR SOLAS SURVEY FOR SLR/GMDSS; Latest Revision Available at https://ww2.eagle.org/en/rules-and-resources/forms.html |
| 2.2.2 | ABS CHECK SHEET FOR SOLAS SURVEY FOR “AIS” RADIO TECHNICIANS SURVEY; Latest Revision Available at https://ww2.eagle.org/en/rules-and-resources/forms.html |
| 2.2.3 | ABS CHECK SHEET FOR SOLAS SURVEY FOR SSAS; Latest Revision Available at https://ww2.eagle.org/en/rules-and-resources/forms.html |
| 2.2.4 | FCC GMDSS Inspection Check Sheet; Latest Revision Available at https://www.fcc.gov/sites/default/files/gmdss-checklist.pdf |
0456_A_TARS-CCSI-MAGNETIC COMPASS SERVICE (2 YR)
| 2.1 | Ritchie Navigation Globemaster Magnetic Compass Service Manual |
| 2.2 | SOLAS V, Regulation 12, Shipborne Navigational Equipment |
| 2.3 | SOLAS V, Regulation 19, Carriage Requirements for Shipborne Navigational Systems and Equipment |
| 2.4 | ISO 25862:2019 (E), Ships and Marine Technology - Marine Magnetic Compasses, Binnacles and Azimuth Reading Devices (Available Commercially)ITEM LOCATION/DESCRIPTION/QUANTITY |
0458_A_TARS-CCSI-ANTENNA MAINTENANCE (2.5 YR)
| 2.1.1 | NAVSEA Tech Manual 0967-LP-177-3020, Installation Details, Communications Antenna Systems |
| 2.1.2 | NAVSEA Drawing 5762871, Antenna Arr Aft Kingpost |
| 2.1.3 | NAVSEA Drawing 5762872, Antenna Arr Main Mast & House Top |
0459_A_TARS-CCSI-ECHO SOUNDER SERVICE (2.5 YR)
| 2.1 | Technical Manual TE360-AV-MMC-010, Echo Depth Sounding System, Model ES-5000/LAZ-5000 |
| 2.2 | MSC Drawing No. 403-8390063, USNS SALVOR (T-ARS 52) Fathometer Replacement Electrical Installation |
| 2.3 | ABS Rules for Survey After Construction |
0460_A_TARS-CCSI-ANNUAL INSPECTION OF MANUALLY OPERATED ALARMS
| 2.1 | S9ARS-BT-SIB-070 Ship Information Book, Interior Communications Systems General Description of Interior Communications - Alarm and Indicating Systems |
| 2.2 | SE677-AR-MMM-010 Interior Communications Switchboards, Main, Local and Test |
| 2.3 | S9086-PA-STM-010 NSTM Chapter 430, Interior Communication Installations |
0490_A_TARS-CSI-SPEED LOG SERVICING (5 YR)
| 2.1 | Tech Manual 5003665, SRD-500A Dual Axis Doppler Speed Log Operation, Service, and Installation Manual |
| 2.2 | MSC Drawing No. 0910-401-1, Doppler Speed Log, SRD-500 Interconnection Wiring Diagram |
0492_A_TARS-CSI- ELECTRONIC TEST EQUIPMENT (GPETE) CALIBRATION (1 YR)
| 2.1.1 | NAVSEA Letter 4734, Policy For Use Of Certified/Accredited OEM Calibrations |
| 2.1.2 | OPNAVINST 3960.16A Navy Test Measurement And Diagnostic Equipment (TMDE); Automatic Test Equipment (ATS); And Metrology And Calibration (METCAL) |
0502_A_OVERHAUL FIRE MONITORS VR25-0054
2.1.1 DWG: DP100- MODEL DP100 FIRE MONITOR
0503_A_AUX FIRE PUMPS OVERHAUL (ABS 5 YRS)
| 2.1.1 | DWG 998-1111-B-11: (4 X 2 X 11 Auxiliary Fire Pump Carver Company) |
| 2.1.2 | M-SERIES PUMPS BUILT THRU JUNE 2022: AVAILABLE AT CARVERPUMP.COM (https://www.carverpump.com/resources/) |
| 2.1.3 | MSC Standard Item No. 87: Shop Overhaul of Centrifugal Pump. |
| 2.1.4 | MSC Standard Item No. 54: Recondition Squirrel Cage Motors, AC Service. |
0504_A_ENGINE JACKET FLUSH VR25-0038
2.0 Reference: None
0546_A_TARS-CSI-AIR REGULATING VALVE REFURBISHMENT (2.5 YR)
| 2.1 | NAVSEA DWG No. 551-5763268, LP and HP Air System Auxiliary Machinery Room |
| 2.2 | NAVSEA DWG No. 551-5763267, LP and HP Air System Main Machinery Room |
| 2.3 | NAVSEA DWG No. 551-5763273, LP and HP Air System FWD Machinery Room |
| 2.4 | NAVSEA DWG No. 551-5763263, High Pressure Air System |
| 2.5 | NAVSEA Tech Manual No. S6434-BD-MMM-010, Marotta Pressure Regulating Manifolds |
0556_TARS_CCSI_INSPECT DECK CRANES (1 YR)
2.1.1 ABS Guide for Certification of Lifting Appliances, Jan 2018 (Latest Edition)
2.1.2 International Standard (ISO) 4309, Cranes - Wire Rope - Care and maintenance, inspection and discard (Latest Edition)
2.1.3 Technical Manual TG811-BP-MMA-010, Electro-Hydraulic Extended Boom Crane, Model Number EB50-65-36
2.1.4 Appleton Marine Drawing BMD-0626, Crane Outline, Crane Model: EB 90-65-36
0561C_A_TARS-CCSI-GAUGE CALIBRATION (5 YR)
| 2.1 | ISO/IEC 17025:2017, General Requirements for the Competence of Testing and Calibration Laboratories (Available Commercially) |
| 2.2 | MSC QMS N7.71.4734.101-Q Shipboard Instrumentation Calibration Requirements |
| 2.3 | USNS SALVOR (T-ARS 52) 5 Year SMS Calibration List |
0562_A_TARS-CCSI-SCBA ANNUAL INSPECTION
| 2.1.1 | Tech Manual, 595160-01-E, Scott Air Pak |
| 2.1.2 | 49 CFR §180, Subpart C - Qualification, Maintenance and Use of Cylinders |
| 2.1.3 | NFPA 1852 Standard on Selection, Care, and Maintenance of Open-Circuit Self-Contained Breathing Apparatus (SCBA) - (Available Commercially) |
| 2.1.4 | NFPA 1989 Standard on Breathing Air Quality for Emergency Services Respiratory Protection - (Available Commercially) |
| 2.1.5 | MSC Drawing No. 085-8195813, Fire Control Plan |
| 2.1.6 | USNS Salvor (T-ARS 52) 2025 SCBA Service Report |
0563B_A_TARS-CCSI-SCBA COMPRESSOR AND FILLING STATION INSPECTION AND MAINTENANCE (2 YR)
| 2.1 | NAVSEA Tech Manual S6226-PD-MMO-010, Self-Contained Breathing Apparatus, Breathing Air Charging System. |
| 2.2 | NAVSEA Drawing No. 551-7578604, SCBA HP Air Mods |
| 2.3 | NFPA 1989, Standard on Breathing Air Quality for Emergency Services Respiratory Protection (Available Commercially) |
0565A_A_TARS-CCSI-FIXED GAS FIREFIGHTING SYSTEM INSPECTION AND TEST (1 YR) (SCSI)
| 2.1.1 | MSC Drawing 085-8195813, Fire Control Plan |
| 2.1.2 | NAVSEA Tech Manual S9555-A6-MMA-010, Fire Extinguishing System, Halon 1301 |
| 2.1.3 | NAVSEA S9555-BC-MMM-010, Halon Fire Extinguishing System |
| 2.1.4 | MSC.1/Circ.1432, 31 May 2012, Revised Guidelines for the Maintenance and Inspection of Fire Protection Systems and Appliances |
| 2.1.5 | MSC.1/Circ.1318, Rev 1, 25 May 2021, Guidelines for the Maintenance and Inspection of Fixed Carbon Dioxide Fire-Extinguishing Systems |
| 2.1.6 | 46 CFR § 91.25-20(a)(1) Fire Extinguishing Equipment (Portable and semi-portable extinguishers) |
0567A_A_TARS-CCSI-FIXED FOAM FIREFIGHTING SYSTEM INSPECTION AND TEST (1 YR) (SCSI)
| 2.1.1 | MSC Drawing No. 085-8195813, Fire Control Plan |
| 2.1.2 | MSC Drawing No. 555-5763292, Diagram AFFF |
| 2.1.3 | NAVSEA Tech Manual S9555-AG-MMM-A10, Fire Extinguishing System (AFFF) |
| 2.1.4 | MSC.1/Circ.1432, 31 May 2012, Revised Guidelines for the Maintenance and Inspection of Fire Protection Systems and Appliances (Available Commercially) |
| 2.1.5 | Foam Concentrate Safety Data Sheet, National Foam, Universal CGC6 |
0569_A_TARS-CCSI-FIRE AND SMOKE DETECTION AND ALARM SYSTEM (1 YR) (SCSI)
| 2.1.1 | 46 CFR §76.27 — Fire Detection and Alarm System, Details, §76.33 — Smoke Detection System, Details, § 76.35 — Manual Alarm System, Details |
| 2.1.2 | SOLAS II-2, Part C, Regulation 7; Detection and Alarm (Available commercially) |
| 2.1.3 | NFPA Code 72 National Fire Alarm and Signaling Code (Available Commercially) |
| 2.1.4 | MSC Drawing 8391349, MCS Fire Control Cable Run Diagram |
| 2.1.5 | Tech Manual S-4-010.965-E_0_0, Fire Alarm System, CS 4000 User Guide |
| 2.1.6 | Tech Manual S-4-010.968-E_5_0, Fire Alarm System CS4000 Service and Maintenance Manual |
| 2.1.7 | MSC Drawing 085-8195813, Fire Control Plan |
0570_A_TARS-CCSI-PORTABLE FIRE EXTINGUISHER SERVICE (1 YR)
| 2.1.1 | MSC Drawing 085-8195813, Fire Control Plan |
| 2.1.2 | USNS Salvor (T-ARS 52) Portable Fire Extinguisher Service Record |
| 2.1.3 | Resolution A.951(23), Adopted on 5 December 2003, Improved Guidelines for Marine Portable Extinguishers (Available Commercially) |
| 2.1.4 | National Fire Protection Association, NFPA 10, Standard for Portable Fire Extinguishers (Available commercially) |
0571_A_TARS-CCSI-FIRE AND SMOKE DAMPER SERVICE (1 YR)
2.1.1 MSC Drawing 085-8195813, Fire Control Plan
0572_A_TARS-CCSI-DEEP FAT FRYER AND RANGE HOOD FIRE EXTINGUISHING SYSTEM (1 YR) (SCSI)
| 2.1.1 | NFPA 17 Standard for Dry Chemical Extinguishing Systems (Available Commercially) |
| 2.1.2 | NFPA 17A Standard for Wet Chemical Extinguishing Systems (Available Commercially) |
| 2.1.3 | ISO 15371, Ships and Marine Technology — Fire-Extinguishing Systems for Protection of Galley Cooking Equipment |
| 2.1.4 | SOLAS Chapter II-2 Construction - Fire Protection, Fire Detection and Fire Extinction, Part C Suppression of Fire, Regulation 10 Firefighting, Para 6 (Available Commercially) |
| 2.1.5 | Tech Manual S6161-HA-FSE-010, Galley Cooking Equipment Exhaust Ventilation |
| 2.1.6 | NAVSEA Drawing No. 651-5763452, Galley and Scullery Arr and Detail |
0573_A_TARS-CCSI-FIRE STATIONS AND HOSES (1 YR)
| 2.1 | MSC Drawing No. 085-8195813, Fire Control Plan |
| 2.2 | 46 CFR §95.10-10, Fire Hydrants and Hose |
0574A_A_TARS-CCSI-FIRE DOORS AND SHUTTERS (1 YR)
| 2.1.1 | MSC Drawing No. 085-8195813, Fire Control Plan (TARS-52 SALVOR) Rev C |
| 2.1.2 | Tech Manual L-T4525-COT-010_0_0, 26” Wide x 54” High, Electro-Hydraulic Sliding Watertight Door |
| 2.1.3 | Subpart 46 CFR 111.99, Fire Door Holding and Release Systems |
| 2.1.4 | SOLAS II-2, Construction, Fire Protection, Fire Detection and Fire Extinction, Part C Suppression of Fire, Regulation 9 Containment of Fire (Available commercially) |
0580_A_TARS-CSI-REFRIGERATION PLANTS SERVICING AND REPAIRS (1 YR)
| 2.1.1. | Tech manual S9516-A1-MM0-010: Ship's Stores Refrigeration Plant, 0.7 Tons Capacity |
| 2.1.2. | NAVSEA DWG 5763547: Piping Arr – Ship Stores Refrigeration |
| 2.1.3. | MSC SWIRRR 019: Motor and Ventilation Fan Repairs |
| 2.1.4. | Carrier Transicold 90YF-020D6: R-134A Condensing Unit, 0.92 tons |
0587_A_TARS-CSI-OILY WATER SEPARATOR SYSTEM SERVICING (5 YR)
| 2.1 | MSC Technical Manual L-T4401-MMA-010, Operating and Maintenance Instructions Oily Water Separator SKI T /S-DEB |
| 2.2 | SSPC-SP 1, Solvent Cleaning Standard (Commercially Available) |
0588_A_TARS-CSI-OIL CONTENT MONITOR CALIBRATION (2 YR) (SCSI)
2.1 MSC Technical Manual NAG2531, TD-107 Oil Content Monitor
0592_A_TARS-CSI-SS DIESEL ENGINE - MINOR OVERHAUL (10K HRS)
| 2.1.1 | Caterpillar Maintenance Management Schedule for Marine Engines (SEBU6102). |
| 2.1.2 | Caterpillar Operation and Maintenance Manual (SEBU5698). |
| 2.1.3 | Caterpillar Service Manual (SEBR0511). |
| 2.1.4 | Technical Manual S9211-A1-MMM-010, Ship’s Service Generator, Chapters 1 through 6, Operation, Maintenance and Repair. |
| 2.1.5 | Technical Manual S9211-A1-MMM-020, Ship’s Service Generator, Chapter 7, Parts List, Chapter 8 Installation. |
0599_A_TARS-CSI-LP AIR COMPRESSOR MINOR OVERHAUL (4K HRS)
2.1 References: Quincy Air Compressor Tech. Manual.65097-1A, QSi-Series.
0602_A_MEDICAL REEFER RENEWAL VR25-0011
2.1.1 MSC Drawing 320-8615057, T-ALT 50-1812, T-ARS Class Biomedical Refrigerator Power System Modification
0604_A_WORKBOAT DAVIT SERVICE
2.1.1 MSCLANT Standard Item No. 87, “Shop Overhaul of Centrifugal Pumps” Revised 2APR93 (SI087)
2.1.2 MSCLANT Standard Items No. 92 September 2003; Sewage Tanks, Initial Coating
2.1.3 NAVSEA TECH MANUAL 0947-LP-229-2010 Sewage Transfer Pumping System. Available onboard.
2.1.4 NAVSEA RECH MANUAL S6225-M8-MMO-010 Aspirator Pump.
Available on board.
2.1.5 MSCLANT Standard Item No. 54, “Recondition Squirrel Cage Motors, AC Service”
2.1.6 NAVSEA DWG. 593-5763364 Rev.(E), “ Diagram Sewage, Collecting, Holding & Transfer.
0607_A_FREEZER DOOR RENEWAL VR23-0004
2.1.1 DWG 5763445: CHILL AND FREEZER STOREROOM A/D
0608_A_PRC DECK RECOAT AND RESEAL
| 2.1.1. | NAVSEA TECHNICAL MANUAL CHAPTER 634 “Deck Coverings” |
| 2.1.2. | Steel Structures Painting Council, Systems and Specifications, Volume 2 |
0609_A_ALLIED DAVIT WINCH RENEWAL
2.1.1 Technical Manual 80-640; Boat Davit, Allied Systems Company, Model D6000FCT, S/N 1984-1986. 15 May 2000 (SALVOR)
0653A_A_TARS-CCSI-ANNUAL RESCUE BOAT INSPECTION
| 2.1.1 | IMO Resolution MSC.402(96) + Corr.1 (adopted on 19 May 2016) Requirements for maintenance, thorough examination, operational testing, overhaul and repair of Lifeboats, Rescue Boats, Launching Appliances and Release Gear. |
| 2.1.2 | USCG NVIC 03-19, Maintenance, thorough examination, operational testing, overhaul and repair of Lifeboats and Rescue Boats, Launching Appliances and Release Gear |
| 2.1.3 | NAVSEA Technical Manual S9008-HM-BIB-010, Boat Information Book for Rigid Inflatable Boat 7-Meter |
0653B_A_TARS-CCSI-ANNUAL RESCUE BOAT DAVIT INSPECTION
| 2.1.1 | IMO Resolution MSC.402(96) + Corr.1 (adopted on 19 May 2016) Requirements for maintenance, thorough examination, operational testing, overhaul and repair of Lifeboats, Rescue Boats, Launching Appliances and Release Gear.-Available commercially |
| 2.1.2 | USCG NVIC 03-19, Maintenance, thorough examination, operational testing, overhaul and repair of Lifeboats and Rescue Boats, Launching Appliances and Release Gear- Available commercially |
| 2.1.3 | NAVSEA Technical Manual S9583-BS-MMC-010, Slewing Arm Davit Model D60000FCT |
0656_A_TARS-CCSI-ANNUAL LIFE RAFT CERTIFICATION
| 2.1.1 | 46 CFR §160.151-57 - Servicing Procedure |
| 2.1.2 | 46 CFR §160.151-37 – Servicing Manual |
| 2.1.3 | 46 CFR §160.151-21 Equipment required for SOLAS A and SOLAS B inflatable liferafts |
| 2.1.4 | USCG NVIC 4-86, 28 MAR 1986, Hydraulic Release Units for Liferafts, Life Floats and Buoyant Apparatus, and Alternate Float-Free Arrangements |
0673_A_TARS-CCSI-READY SERVICE LOCKER OVERHAUL (5 YR)
| 2.1.1 | NAVSEA OP 4, 0640-LP-111-4501, AMMUNITION AND EXPLOSIVES SAFETY AFLOAT |
| 2.1.2 | NAVSEA OP 3347, UNITED STATES NAVY ORDNANCE SAFETY PRECAUTIONS |
| 2.1.3 | NSTM Chapter 700, S9086-XG-STM-010, SHIPBOARD AMMUNITION HANDLING AND STOWAGE |
| 2.1.4 | Surface Preparation Standard, SSPC-SP-1, Solvent Cleaning (Available commercially) |
| 2.1.5 | Surface Preparation Standard, SSPC-SP-10/NACE NO. 2, Near-White Blast Cleaning (Available commercially) |
| 2.1.6 | Surface Preparation Standard, SSPC-SP-11, Power Tool Cleaning (Available commercially) |
| 2.1.7 | MSC PPG Paint Handbook |
| 2.1.8 | PPG Product Data Sheets; Dimetcote 302H, Amercoat 240, Amercoat T10, Amercoat T65, Amershield, and Prep 88 |
0801_A_#1 AC CHILLER CONDENSER TUBE SHEET VR25-0034
2.1 REFERENCE: None
0802_A_AC CHILLER ECONIMIZER RENEWAL VR25-0057
2.1.1 Tech Manual S6230-BP-MMM-010: 35 TON Capacity Air Conditioning Plant.
0853_A_TARS-CCSI-ACCOMMODATION VENT SYSTEM CLEANING (5 YR)
| 2.1 | MSC Drawing No. 512-5763044, HVAC Diagram |
| 2.2 | NAVSEA Drawing No. 512-5364401, HVAC Diagram |
| 2.3 | NAVSEA Drawing No. 512-5763048, HVAC List of Equipment |
| 2.4 | NSTM, Chapter 510, HVAC Systems for Surface Ships |
| 2.5 | ANSI/ASHRAE/ACCA Standard 180-2018, Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems |
0881_A_TARS-CSI-AC CHILLER SERVICING (1 YR)
| 2.1.1. | Tech Manual S6230-BP-MMM-010: 35 TON Capacity Air Conditioning Plant |
| 2.1.2. | Carrier Transicold 90YH-060DP6: R-134A Condensing Unit, 34.9 tons |
0901_A_TARS-CCSI-DRYDOCKING AND UNDOCKING THE VESSEL (2.5 YR)
| 2.1.1 | MSC Drawing No. 085-8387903, Trim and Stability Booklet |
| 2.1.2 | NAVSEA Drawing No. 997-5763503, Class Guidance Docking Drawing |
| 2.1.3 | NAVSEA Drawing No. 801-5763549, Docking Drawing |
| 2.1.4 | NAVSEA Drawing No. 801-5763566, Tank Capacity Curves |
| 2.1.5 | NAVSEA Drawing No. 801-5763567, Tank Sounding, Gauging, and Ullage Tables |
| 2.1.6 | Safety Certification Program for Dry-docking Facilities and Shipbuilding Ways for U.S. Navy Ships, MIL-STD 1625 (latest revision) |
| 2.1.7 | MSC QMS N7.721.9997.8-Q, Dry Dock Standards for MSC Ship Availabilities |
0902_A_FAIRWATER AND BEARINGS INSPECTION
2.1.1 DWG 5762716- ARR MN PRPL SHAFTING
2.1.2 DWG 5762717- ROPE GUARDS, COUPLING COVERS AND FAIRWATER
0903_A_OVERHAUL CPP OD-BOX
2.1.1 Naval Ships Technical Manual, S9245-AJ-MMM-010, CPP System Model No.79
0904_A_SEACHEST VENTS FLUSHING
| 2.1.1 | DWG 5763019- DIAGRAM OVERFLOWS, AIR ESCAPES AND SOUNDING TUBES |
| 2.1.2 | DWG 5763508- SEA CHEST CONNECTIONS |
0905_A_FIRE PUMP VALVES RENEWAL
2.1.1 NAVSEA DWG-5763100 Fire Main Diagram.
0906_A_SERVICE BOW THRUSTER
2.1 NAVSEA Tech Manual 0944-LP-007-9010 (Available onboard during bidder’s survey)
0907_A_RUDDER INSPECTION, SEALS AND BEARINGS RENEWAL
| 2.1.1 | MSC Standard Item No. 64, Rudder and Stern Frame Exam |
| 2.1.2 | NAVSEA DWG 562-5763333, Rev G, Rudder Stock & Details |
| 2.1.3 | NAVSEA DWG 562-5763332, Rev C, Rudder |
| 2.1.4 | NAVSEA DWG 562-6584210, Rudder Post Seal Modification |
| 2.1.5 | NAVSEA DWG 562-6584211, Rudder Bearing Lubrication Modification |
| 2.1.6 | NAVSEA TECH MANUAL S9561-BB-MMM, STEERING GEAR- Located on-board. |
0908_A_RUDDER REPAIR
| 2.1.1 | MSC Standard Item No. 64, Rudder and Stern Frame Exam |
| 2.1.2 | NAVSEA DWG 562-5763333, Rev G, Rudder Stock & Details |
| 2.1.3 | NAVSEA DWG 562-5763332, Rev C, Rudder. |
| 2.1.4 | STRUCTIRAL DETAILS 567-5762672 |
0909_A_SEA VALVES OVERHAUL
| 2.1.1 | MSC Drawing No. 256-5762727, Diagram Sea Water Cooling |
| 2.1.2 | NAVSEA Drawing No. 163-5763508, Sea chests Connections |
| 2.1.3 | NAVSEA Drawing No. 801-5763549, Docking Plan |
| 2.1.4 | L-T4113-SHP-010: Technical Manual Electric Valve Actuator Tri-Tech Company |
0910_A_STERN TUBE BARRELS EXTERNAL SURFACE PRESERVATION
| 2.1.1 | DWG 5762691- STERN TUBE |
| 2.1.2 | DWG 5763438- CATHODICT PROTECTION ARR AND DET |
0953_A_TARS-CCSI-ANCHORS, CHAINS AND LOCKERS-FULL BLAST (5 YR)
| 2.1 | NAVSEA Drawing No. 581-5763340, Anchor Handling Arrangement and Details |
| 2.2 | NAVSEA Drawing No. R-14162, Assembly Capstan Windlass |
| 2.3 | NAVSEA Tech Manual S9581-AY-MMO-010 Electro-Hydraulic Capstan-Windlass, Model X-1812 |
| 2.4 | Surface Preparation Standard, SSPC-SP-6/NACE No. 3, Commercial Blast Cleaning (Available Commercially) |
| 2.5 | PPG PMC-MSC Paint Handbook |
| 2.6 | PPG Product Data Sheets, Amercoat 240 and Amershield |
0957_A_TARS-CCSI-PROPELLER CLEAN AND POLISH - ON DOCK (2.5 YR)
| 2.1.1 | NAVSEA Drawing No. 801-5763549, Docking Plan |
| 2.1.2 | NAVSEA Drawing No. 107951003, Propeller Blade |
| 2.1.3 | NAVSEA Tech Pub No. S9086-HP-STM-010, NSTM Chapter 245, Propellers and Propulsors |
| 2.1.4 | NAVSEA Technical Manual S9245-BK-TRS-010, Propeller Hub Assembly and Blades |
0959_A_TARS-CCSI-UNDERWATER HULL CLEANING AND PAINTING - NEAR WHITE BLAST (10 YR)
| 2.1.1 | NAVSEA Drawing No. 801-5763549, Docking Plan |
| 2.1.2 | NAVSEA Drawing No. 602-5763404, Hull Markings |
| 2.1.3 | Surface Preparation Standard, SSPC-SP WJ-1/NACE WJ-1, Waterjet Cleaning of Metals – Clean to Bare Substrate (WJ-1) (Available commercially) |
| 2.1.4 | Surface Preparation Standard, SSPC-SP10/NACE 2, Near White Metal Blast Cleaning (Available commercially) |
| 2.1.5 | PPG PMC - MSC Paint Handbook |
| 2.1.6 | PPG Product Data Sheets; Amercoat 240 and Amershield |
| 2.1.7 | NAVSEA Tech Pub No. S9086-VF-STM-010, NSTM Chapter 633 – Cathodic Protection |
0962_A_TARS-CCSI-CATHODIC PROTECTION SYSTEM (5 YR)
| 2.1 | NAVSEA Tech Manual S9633-AA-MMM-010, Cathodic Protection System |
| 2.2 | NAVSEA Drawing No. 633-5763438, Cathodic Protection System, Arrangement and Details |
| 2.3 | NAVSEA Drawing No. 320-8498133, Cathodic Protection EWD |
| 2.4 | NAVSEA Drawing No. 320-8498134, Cathodic Protection IWD |
| 2.5 | NAVSEA Drawing No. 801-5763549, Docking Drawing (T-ARS 52) |
| 2.6 | NSTM 633, S9086-VF-STM-010, Cathodic Protection |
0963_A_TARS-CCSI-SEA CHEST MARINE GROWTH PREVENTION SYSTEM (5 YR)
2.1 Tech Manual OM-SWT-1, SWT Dosing Unit Model 2 Operation Manual
0966_A_TARS-CCSI-SHAFT ALIGNMENT AND BEARING REACTION CHECKS (2.5 YR) (SCSI)
| 2.1.1 | NAVSEA Drawing No. 243-5762716, Arrangement Main Propulsion Shafting |
| 2.1.2 | NAVSEA Drawing No. 244-5762718, Installation Details for Shaft Bearings and Seals |
| 2.1.3 | Bird-Johnson Company Drawing No. 107953004, Stern Tube Shaft |
| 2.1.4 | NAVSEA Drawing No. 803-1385664, Bearings, Stern Tube and Strut (Arrangement Details) |
| 2.1.5 | NAVSEA Tech Manual, S9086-HM-STM-010, NSTM Chapter 243 Propulsion Shafting |
| 2.1.6 | NAVSEA Tech Manual S6420-AC-HBK-010, Handbook, Bearings, Measurement of Load |
| 2.1.7 | ABS Guidance Notes on Propulsion Shafting Alignment, Feb 2014 |
0970_A_TARS-CCSI-FREEBOARD PRESERVATION - FULL BLAST (10 YR)
| 2.1 | MSC Drawing No. 801-5763565, Booklet of General Drawings |
| 2.2 | Surface Preparation Standard, SSPC-SP WJ-1/NACE WJ-1, Waterjet Cleaning of Metals – Clean to Bare Substrate (WJ-1) (Available commercially) |
| 2.3 | Surface Preparation Standard, SSPC-SP10/NACE 2, Near White Metal Blast Cleaning (Available commercially) |
| 2.4 | PPG PMC - MSC Paint Handbook |
| 2.5 | PPG Product Data Sheets; Amercoat 240 and Amershield |
0984_A_TARS-CSI-HULL ZINC REPLACEMENT (5 YR)
| 2.1 | NAVSEA Drawing No. 803-921865, Cathodic Protection Hull Zinc Anodes |
| 2.2 | NAVSEA Drawing No. 803-1385664, Bearings, Stern Tube and Strut Arrg. Det. |
| 2.3 | NAVSEA Drawing No. 633-5763438, Cathodic Protection Arrg and Det |
0986_A_TARS CSI STERN TUBE SEAL MINOR OVERHAUL
| 2.1 | John Crane Marine Drawing No. WG #US72738-01, Type MX9 Stern Tube Seals |
| 2.2 | MX-9 Stern Tube Seal Inspection and Repair |
| 2.3 | Naval Ships Technical Manual, S9086-HM-STM-010/CH 244, Propulsion Bearings and Seals |
| 2.4 | NAVSEA Drawing No. 243-5762716, Main Propulsion Shafting |
| 2.5 | NAVSEA Drawing No. 244-5762718, Installation Details for Shaft Bearings and Seals |
0992_A_TARS-CSI-CPP SYSTEM SERVICE - INTERMEDIATE DOCKING (5 YR)
2.1.1. Naval Ships Technical Manual, S9245-AJ-MMM-010, CPP System Model No.79
GOVERNMENT FURNISHED MATERIAL (GFM) LISTING
USNS SALVOR (T-ARS- 52)
| Line Number |
| Work Item Name |
| Material Descriptions |
| Part Number |
| Quantity |
| Unit |
| 1 |
| REPLACE BRIDGE WINDOWS |
| WINDOW,ROTARY |
| KS-18000-D |
| 2.00000 |
| Each |
| 2 |
| REPLACE BRIDGE WINDOWS |
| HEATED GLASS 25” X 33” |
| KS-24484 |
| 4.00000 |
| Each |
| 3 |
| REPLACE BRIDGE WINDOWS |
| HEATED GLASS 25” X 29” |
| KS-23324 |
| 4.00000 |
| Each |
| 4 |
| SEWAGE HEADER PIPE RENEWAL |
| FLANGE,PIPE |
| MILF20042 |
| 12.00000 |
| Each |
| 5 |
| SEWAGE HEADER PIPE RENEWAL |
| COUPLING,TUBE |
| MIL-F-1183 |
| 2.00000 |
| Each |
| 6 |
| SEWAGE HEADER PIPE RENEWAL |
| COUPLING,PIPE |
| MIL-F-1183-1 |
| 4.00000 |
| Each |
| 7 |
| SEWAGE HEADER PIPE RENEWAL |
| ELBOW,PIPE |
| MIL-F-1183/5 |
| 2.00000 |
| Each |
| 8 |
| SEWAGE HEADER PIPE RENEWAL |
| TUBE,METALLIC |
| MIL-T-16420 |
| 30.00000 |
| Foot |
| 9 |
| SEWAGE HEADER PIPE RENEWAL |
| TUBE,METALLIC |
| MIL-T-16420-1 |
| 15.00000 |
| Foot |
| 10 |
| SEWAGE HEADER PIPE RENEWAL |
| SCREW,CAP,HEXAGON HEAD |
| MIL-DTL-1222J |
| 1.00000 |
| Each |
| 11 |
| SEWAGE HEADER PIPE RENEWAL |
| NUT,PLAIN,HEXAGON |
| 0.62511UNC2BT1G400SNSA/BEA |
| 60.00000 |
| Each |
| 12 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| AMERCOAT 240 EPOXY RED |
| AMERCOAT 240 |
| 1.00000 |
| Gallon |
| 13 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| AMERCOAT 240 EPOXY BUFF |
| AMERCOAT 240-1 |
| 1.00000 |
| Gallon |
| 14 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| AMERCOAT 240 EPOXY WHITE |
| AMERCOAT 240-2 |
| 1.00000 |
| Gallon |
| 15 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| AMERSHIELD POLUYRETHANE |
| AMERSHIELD |
| 1.00000 |
| Gallon |
| 16 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| AMERCOAT T-10 SOLVENT |
| AMERCOAT T-10 |
| 1.00000 |
| Gallon |
| 17 |
| STARBOARD VENT PLENUM STEEL RENEWAL VR25-0027 |
| AMERCOAT 65 SOLVENT |
| AMERCOAT 65 |
| 1.00000 |
| Gallon |
| 18 |
| JOINER DOORS RENEWAL |
| DOOR METAL MARINE,TYPE1 26” X 70”. |
| 805-4629248 |
| 2.00000 |
| Each |
| 19 |
| TRASH ROOM BULKHEAD STEEL RENEWAL VR25-0024 |
| AMERCOAT 240 EPOXY PASTEL GREEN |
| AMERCOAT 240-3 |
| 1.00000 |
| Gallon |
| 20 |
| TRASH ROOM BULKHEAD STEEL RENEWAL VR25-0024 |
| AMERCOAT 240 EPOXY BUFF |
| AMERCOAT 240-4 |
| 1.00000 |
| Gallon |
| 21 |
| TRASH ROOM BULKHEAD STEEL RENEWAL VR25-0024 |
| AMERCOAT 240 EPOXY WHITE |
| AMERCOAT 240-5 |
| 1.00000 |
| Gallon |
| 22 |
| WATERTIGHT DOORS OVERHAUL (55" X 81") |
| AMERCOAT 65 SOLVENT |
| AMERCOAT 65-1 |
| 1.00000 |
| Gallon |
| 23 |
| WATERTIGHT DOORS OVERHAUL (55" X 81") |
| DIMETCOTE 240 RED OXIDE |
| DIMETCOTE 240 |
| 10.00000 |
| Gallon |
| 24 |
| WATERTIGHT DOORS OVERHAUL (55" X 81") |
| AMERCOAT 240 BUFF |
| AMERCOAT 240-6 |
| 15.00000 |
| Gallon |
| 25 |
| WATERTIGHT DOORS OVERHAUL (55" X 81") |
| AMERSHIELD HAZE GRAY |
| AMERSHIELD-1 |
| 10.00000 |
| Gallon |
| 26 |
| WATERTIGHT DOORS OVERHAUL (55" X 81") |
| AMERCOAT 5450 SOFeet WHITE (FIRE RETARDANT) |
| AMERCOAT 5450-6 |
| 10.00000 |
| Gallon |
| 27 |
| FAN ROOM DECK DRAIN REPAIR |
| 1-1/2” TYPE “C” SCUPPER DRAINS, BRONZE |
| UNKNOWN |
| 1.00000 |
| Each |
| 28 |
| FAN ROOM DECK DRAIN REPAIR |
| CUNI PIPE 1-1/2” DIAMETER |
| UNKNOWN-1 |
| 4.00000 |
| Foot |
| 29 |
| MAIN MAST PRESERVATION (VR25-0035) |
| AMERCOAT 240 HAZE GRAY |
| AMERCOAT 240-7 |
| 1.00000 |
| Gallon |
| 30 |
| MAIN MAST PRESERVATION (VR25-0035) |
| AMERCOAT 240 OFF-WHITE |
| AMERCOAT 240-8 |
| 1.00000 |
| Gallon |
| 31 |
| MAIN MAST PRESERVATION (VR25-0035) |
| AMERCOAT 240 RED OXIDE |
| AMERCOAT 240-9 |
| 1.00000 |
| Gallon |
| 32 |
| MAIN MAST PRESERVATION (VR25-0035) |
| AMERSHEILD HAZE GRAY |
| AMERSHIELD-2 |
| 1.00000 |
| Gallon |
| 33 |
| LIGHTNING ARRESTER VR25-0021 |
| AMERCOAT 240 RED |
| AMERCOAT 240-10 |
| 1.00000 |
| Gallon |
| 34 |
| LIGHTNING ARRESTER VR25-0021 |
| AMERCOAT 240 BUFF |
| AMERCOAT 240-11 |
| 1.00000 |
| Gallon |
| 35 |
| LIGHTNING ARRESTER VR25-0021 |
| AMERSHIELD HAZE GRAY |
| AMERSHIELD-3 |
| 1.00000 |
| Gallon |
| 36 |
| ASW CUNI PIPE RENEWAL |
| 4” CUNI 90/10 PIPE |
| UNKNOWN-2 |
| 10.00000 |
| Foot |
| 37 |
| ASW CUNI PIPE RENEWAL |
| 4” SHORT ELBOW 45-DEGREE BRONZE SILVER BRACE |
| UNKNOWN-3 |
| 2.00000 |
| Each |
| 38 |
| ASW CUNI PIPE RENEWAL |
| STRAIGHT BRONZE FITTINGS |
| UNKNOWN-4 |
| 2.00000 |
| Each |
| 39 |
| BILGE PRESERVATION |
| AMERCOAT 240 EPOXY PASTEL GREEN |
| AMERCOAT 240-12 |
| 1.00000 |
| Gallon |
| 40 |
| BILGE PRESERVATION |
| AMERCOAT 240 EPOXY BUFF |
| AMERCOAT 240-13 |
| 1.00000 |
| Gallon |
| 41 |
| BILGE PRESERVATION |
| AMERCOAT 240 EPOXY RED OXIDE |
| AMERCOAT 240-14 |
| 1.00000 |
| Gallon |
| 42 |
| BILGE PRESERVATION |
| AMERCOAT T-10 SOLVENT |
| AMERCOAT T-10-1 |
| 1.00000 |
| Gallon |
| 43 |
| MOORING STRUCTURE PRESERVATION |
| AMERCOAT 240 EPOXY RED OXIDE |
| AMERCOAT 240-15 |
| 10.00000 |
| Gallon |
| 44 |
| MOORING STRUCTURE PRESERVATION |
| AMERCOAT 240 EPOXY OFF-WHITE |
| AMERCOAT 240-16 |
| 10.00000 |
| Gallon |
| 45 |
| MOORING STRUCTURE PRESERVATION |
| AMERSHIELD POLUYRETHANE HAZE GRAY |
| AMERSHIELD-4 |
| 10.00000 |
| Gallon |
| 46 |
| MOORING STRUCTURE PRESERVATION |
| AMERCOAT T-10 SOLVENT |
| AMERCOAT T-10-2 |
| 5.00000 |
| Gallon |
| 47 |
| MOORING STRUCTURE PRESERVATION |
| AMERCOAT 65 SOLVENT |
| AMERCOAT 65-2 |
| 5.00000 |
| Gallon |
| 48 |
| MOORING STRUCTURE PRESERVATION |
| PREP 88 CLEANER |
| PREP 88 |
| 5.00000 |
| Gallon |
| 49 |
| TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION |
| AMERCOAT 240 EPOXY RED OXIDE |
| AMERCOAT 240-17 |
| 20.00000 |
| Gallon |
| 50 |
| TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION |
| AMERCOAT 240 EPOXY OFF-WHITE |
| AMERCOAT 240-18 |
| 25.00000 |
| Gallon |
| 51 |
| TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION |
| AMERSHIELD POLUYRETHANE HAZE GRAY |
| AMERSHIELD-5 |
| 20.00000 |
| Gallon |
| 52 |
| TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION |
| AMERCOAT T-10 SOLVENT |
| AMERCOAT T-10-3 |
| 10.00000 |
| Gallon |
| 53 |
| TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION |
| AMERCOAT 65 SOLVENT |
| AMERCOAT 65-3 |
| 10.00000 |
| Gallon |
| 54 |
| TOPSIDE CRADLES AND FOUNDATIONS PRESERVATION |
| PREP 88 CLEANER |
| PREP 88-1 |
| 10.00000 |
| Gallon |
| 55 |
| VOID, COFFERDAM, PIPING TUNNELS PRESERVATION |
| AMERCOAT 240 EPOXY BUFF |
| AMERCOAT 240-19 |
| 30.00000 |
| Gallon |
| 56 |
| VOID, COFFERDAM, PIPING TUNNELS PRESERVATION |
| AMERCOAT 240 EPOXY RED OXIDE |
| AMERCOAT 240-20 |
| 10.00000 |
| Gallon |
| 57 |
| VOID, COFFERDAM, PIPING TUNNELS PRESERVATION |
| AMERCOAT 240 EPOXY OFF-WHITE |
| AMERCOAT 240-21 |
| 30.00000 |
| Gallon |
| 58 |
| VOID, COFFERDAM, PIPING TUNNELS PRESERVATION |
| AMERCOAT T-10 SOLVENT |
| AMERCOAT T-10-4 |
| 5.00000 |
| Gallon |
| 59 |
| FAN ROOM PRESERVATION |
| AMERCOAT 240 EPOXY RED OXIDE |
| AMERCOAT 240-22 |
| 30.00000 |
| Gallon |
| 60 |
| FAN ROOM PRESERVATION |
| AMERCOAT 240 EPOXY OFF-WHITE |
| AMERCOAT 240-23 |
| 10.00000 |
| Gallon |
| 61 |
| FAN ROOM PRESERVATION |
| AMERCOAT 240 EPOXY OFF-WHITE |
| AMERCOAT 240-24 |
| 30.00000 |
| Gallon |
| 62 |
| FAN ROOM PRESERVATION |
| AMERSHIELD POLUYRETHANE HAZE GRAY |
| AMERSHIELD-6 |
| 15.00000 |
| Gallon |
| 63 |
| FAN ROOM PRESERVATION |
| AMERCOAT T-10 SOLVENT |
| AMERCOAT T-10-5 |
| 5.00000 |
| Gallon |
| 64 |
| FAN ROOM PRESERVATION |
| AMERCOAT 15 SOLVENT |
| AMERCOAT 15 |
| 5.00000 |
| Gallon |
| 65 |
| BEARING INSPECTION |
| BEARING CARTRIDGE |
| 01-BCP-902-EXIG |
| 2.00000 |
| Each |
| 66 |
| BEARING INSPECTION |
| BEARING UNIT HOUSING |
| 01-P-900 |
| 2.00000 |
| Each |
| 67 |
| BEARING INSPECTION |
| LINESHAFeet BEARING SEAL RING |
| ATLS-902 |
| 4.00000 |
| Each |
| 68 |
| 1SG FIELD FLASH CONTROL |
| CIRCUIT BOARD, FIRING |
| 9-1079-03-100 |
| 1.00000 |
| Each |
| 69 |
| 1SG FIELD FLASH CONTROL |
| MODULE, VOLTAGE REGULATOR AND UNDER FREQUENCY |
| 9-1079-04-100 |
| 1.00000 |
| Each |
| 70 |
| CLEANING AND INSPECTION |
| AEROSHELL 22 GREASE |
| AEROSHELL 22 |
| 1.00000 |
| Gallon |
| 71 |
| ANNUAL INSPECTION OF MANUALLY OPERATED ALARMS |
| LOUDSPEAKER |
| UNKNOWN-5 |
| 2.00000 |
| Each |
| 72 |
| ANNUAL INSPECTION OF MANUALLY OPERATED ALARMS |
| GENERAL ALARM BELL |
| UNKNOWN-6 |
| 5.00000 |
| Each |
| 73 |
| AUX FIRE PUMPS OVERHAUL |
| GASKET |
| 073-1420002-376 |
| 2.00000 |
| Each |
| 74 |
| AUX FIRE PUMPS OVERHAUL |
| GASKET |
| 073-1420005-424 |
| 2.00000 |
| Each |
| 75 |
| AUX FIRE PUMPS OVERHAUL |
| GASKET |
| 073-1420006-424 |
| 2.00000 |
| Each |
| 76 |
| AUX FIRE PUMPS OVERHAUL |
| SEAL ASSEMBLY,SHAFeet,SPRING LOADED |
| 091-175-99-0008 |
| 2.00000 |
| Each |
| 77 |
| AUX FIRE PUMPS OVERHAUL |
| PACKING,PREFORMED |
| 700-014-433C |
| 4.00000 |
| Each |
| 78 |
| AUX FIRE PUMPS OVERHAUL |
| O-RING |
| 700-276-433C |
| 4.00000 |
| Each |
| 79 |
| AUX FIRE PUMPS OVERHAUL |
| O-RING |
| 700-904-433C |
| 20.00000 |
| Each |
| 80 |
| AUX FIRE PUMPS OVERHAUL |
| O-RING |
| 700-028-433C |
| 4.00000 |
| Each |
| 81 |
| AUX FIRE PUMPS OVERHAUL |
| BOLT,CLOSE TOLERANCE |
| 804-0500-08C202 |
| 2.00000 |
| Each |
| 82 |
| AUX FIRE PUMPS OVERHAUL |
| SETSCREW |
| 864-10-02C202 |
| 8.00000 |
| Each |
| 83 |
| AIR REGULATING VALVE REFURBISHMENT |
| VALVE ASSEMBLY, MANIFOLD |
| 283996-001 |
| 1.00000 |
| Each |
| 84 |
| REFRIGERATION PLANTS SERVICING AND REPAIRS |
| AMERCOAT 240 BUFF |
| AMERCOAT 240-25 |
| 1.00000 |
| Gallon |
| 85 |
| REFRIGERATION PLANTS SERVICING AND REPAIRS |
| AMERCOAT 240 RED OXIDE |
| AMERCOAT 240-26 |
| 1.00000 |
| Gallon |
| 86 |
| REFRIGERATION PLANTS SERVICING AND REPAIRS |
| AMERCOAT 240 DARK GRAY |
| AMERCOAT 240-27 |
| 1.00000 |
| Gallon |
| 87 |
| REFRIGERATION PLANTS SERVICING AND REPAIRS |
| REFRIGERANT |
| UNKNOWN-7 |
| 1.00000 |
| Gallon |
| 88 |
| REFRIGERATION PLANTS SERVICING AND REPAIRS |
| OIL |
| UNKNOWN-8 |
| 1.00000 |
| Gallon |
| 89 |
| DIESEL ENGINE - MINOR OVERHAUL |
| LUBE OIL |
| UNKNOWN-9 |
| 1.00000 |
| Gallon |
| 90 |
| DIESEL ENGINE - MINOR OVERHAUL |
| ENGINE COOLANT |
| UNKNOWN-10 |
| 1.00000 |
| Gallon |
| 91 |
| LP AIR COMPRESSOR MINOR OVERHAUL |
This is the start of the file's text. The full file is on GovTribe.