Update Isolation Rooms 100CD Submittal Package.pdf

PDF 29 MB Posted

Attached to
Z2DA--(CON) 442-20-004 Update Isolation Rooms (VA-21-00049451)
Solicitation number
36C25921R0070
Issued by

About this file

This solicitation is for construction services to update three isolation rooms at the Cheyenne VA Medical Center located in Cheyenne, Wyoming. The scope of work includes updating two existing isolation rooms and constructing a third isolation room to meet current standards. The project is estimated to cost between $500,000 and $1,000,000. It has been set aside for Service Disabled Veteran Owned Small Businesses. Responses are due by January 15, 2022. The selected contractor will be responsible for adhering to all applicable codes and regulations, coordinating any necessary outages, and completing construction by the specified deadline while minimizing impacts to medical center operations. The contractor must also meet safety, quality, and scheduling requirements.

View the file

Other files

File Type Posted
36C25921R0070 0003.docx DOCX document
Additional Phasing Considerations.pdf PDF
Update Isolation Room Bid RFI 1.docx DOCX document
36C25921R0070 0002.docx DOCX document
Site Visit Attendance.pdf PDF
36C25921R0070 Corrected Pg 18.pdf PDF
36C25921R0070 0001.docx DOCX document
36C25921R0070 Full Solicitation.docx DOCX document
S02 Past Performance Questionnaire.docx DOCX document
J and A 36C259-21-AP-2342 Brand Name Lifts 442 Signed.pdf PDF
36C25921R0070_2.docx DOCX document
SELF-PERFORMED CALCULATIONS.docx DOCX document
Update Isolation Rooms 100CD Specifications.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N o rt h

VICINITY MAP

SITE MAP

N o rt h

C o n v e rs e A v e

E Pershing Blvd E Pershing Blvd

C o n v e rs e A v e

Dell Range Blvd

Dell Range Blvd

I-

I-

I-

E Pershing Blvd

I-80

I-80

I-80

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

GI001

COVER SHEET CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

VETERANS ADMINISTRATION

2360 E. PERSHING AVE, CHEYENNE, WY 82001

VAMC PROJECT #: 442-20-004

CHEYENNE VAMC UPDATE ISOLATION ROOMS

SHEET # SHEET NAME

GENERAL

GI001 COVER SHEET

GI002 GENERAL INFORMATION AND ABBREVIATIONS

GI003 ACCESSIBILITY STANDARDS

GI004 STATEMENT OF CONDITIONS

GI005 PHASING PLAN

ARCHITECTURAL

AD112 SECOND FLOOR - OVERALL FLOOR PLAN & RCP - DEMOLITION

AD113 PENTHOUSE - FLOOR PLAN - DEMOLITION

AD130 ROOF PLAN - DEMOLITION

A112 SECOND FLOOR - OVERALL FLOOR PLAN & RCP

A113 PENTHOUSE - FLOOR PLAN

A130 ROOF PLAN

A410 ENLARGED PLANS & ELEVATIONS

A411 ENLARGED PLANS & ELEVATIONS

A412 ENLARGED PLANS & ELEVATIONS

A420 ENLARGED PLANS - FINISHES

A530 ROOF AND ENVELOPE DETAILS

A610 WALL TYPE SCHEDULE - WALL & CEILING DETAILS

A620 DOOR SCHEDULE & DOOR TYPES

PLUMBING

P-001 PLUMBING ABBREVIATIONS, SYMBOLS, AND LEGENDS

PP112 SECOND FLOOR PLUMBING PIPING PLANS

MECHANICAL

M-001 MECHANICAL ABBREVIATIONS AND GENERAL NOTES

M-002 MECHANICAL SYMBOLS AND LEGENDS

MH112 SECOND FLOOR MECHANICAL DUCTWORK PLANS

MH113 PENTHOUSE MECHANICAL DUCTWORK PLANS

MH114 PENTHOUSE ROOF MECHANICAL DUCTWORK PLAN

MP112 SECOND FLOOR MECHANICAL PIPING PLANS

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-601 MECHANICAL EQUIPMENT SCHEDULES

M-701 MECHANICAL CONTROLS

M-702 SECOND FLOOR POSITIVE MODE AIRFLOWS DIAGRAM

ELECTRICAL

E-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES

E-002 ELECTRICAL SYMBOLS

ED111 SECOND FLOOR ELECTRICAL DEMO PLAN

EL111 SECOND FLOOR ELECTRICAL LIGHTING PLAN

EP111 SECOND FLOOR AND ROOF ELECTRICAL POWER PLANS

EP112 PENTHOUSE ELECTRICAL POWER PLAN

E-501 ELECTRICAL DETAILS

E-601 ELECTRICAL ONE-LINE AND PANEL SCHEDULES

E-602 LIGHTING SCHEDULES AND TYPICAL WIRING DIAGRAMS

SHEET INDEXAREA OF WORK PROJECT AXONOMETRIC

A. ALL CONTRACTORS AND THEIR SUPERVISORY PERSONNEL MUST REVIEW THE GENERAL AND SUPPLEMENTARY

CONDITIONS TO THE CONTRACT.

B. ALL WORK MUST CONFORM WITH PLANS AND SPECIFICATIONS.

C. CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK.

D. CONTRACTOR MUST BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND THE

SAFETY OF ALL CONSTRUCTION PERSONNEL AND VISITORS.

E. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS

SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR.

F. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THAT INSTALLER'S WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH

INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.

G. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT VHA COR FOR CLARIFICATIONS, IF

REQUIRED.

H. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE FACE OF GYPSUM WALL BOARD (FOG), FACE OF MASONRY (FOM), FACE OF CONCRETE WALLS (FOC) AND COLUMN GRID LINES, UNLESS OTHERWISE NOTED OR INDICATED.

I. WALL THICKNESSES ARE NOMINAL DIMENSIONS, NOT ACTUAL DIMENSIONS. ALL STUD WALL THICKNESSES ARE 5", UNLESS

DIMENSIONED OTHERWISE.

J. ALL MASONRY WALLS ARE 8" THICK (NOMINAL), UNLESS DIMENSIONED OR NOTED OTHERWISE.

K. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR DIMENSION IS REPRESENTATIVE OF, OR THE

SAME, FOR SIMILAR CONDITIONS THROUGHOUT.

L. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN, SECTION, & DETAIL DRAWINGS, ETC), CONTACT VHA COR FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION, THE MOST EXPENSIVE AND/OR

STRICTEST REQUIREMENTS, AS INDICATED BY THE VHA COR, MUST GOVERN.

M. IF THERE ARE ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT VHA COR FOR

CLARIFICATION.

N. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS MUST BE REPORTED TO THE VHA COR IN

WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK.

O. ANY AND ALL DISCREPANCIES MUST BE REPORTED TO THE VHA COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. IN THESE INSTANCES, NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE VHA COR'S WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR MUST REPAIR AND/OR REPLACE ANY UNAUTHORIZED WORK, AS INDICATED BY THE VHA COR, AT NO

ADDITIONAL COST TO THE VHA.

P. ALL DISSIMILAR METAL MATERIALS MUST BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION MATERIAL; REFER TO

SPECIFICATIONS.

Q. ALL EXTERIOR EXPOSED STEEL MUST BE PAINTED; REFER TO APPLICABLE SPECIFICATIONS.

R. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALL PANELS AND AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE, ETC, MUST BE SEALED, CAULKED, FLASHED OR WEATHER-STRIPPED AS REQUIRED FOR COMPATIBILITY WITH ADJACENT MATERIALS AND TO ELIMINATE AIR

LEAKAGE AND WATER ENTRY; REFER TO SPECIFICATIONS.

S. PROVIDE SEALANT AND/OR CAULKING BETWEEN DISSIMILAR ADJOINING INTERIOR MATERIALS. (I.E. WINDOW SILLS TO

GWB, ACT CEILINGS TO MASONRY WALLS, ETC.); REFER TO APPLICABLE SPECIFICATIONS.

T. DOOR OPENINGS NOT LOCATED BY DIMENSION MUST BE CENTERED IN WALL SHOWN OR LOCATED 2" FROM FINISH WALL TO FINISH JAMB, ALWAYS ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE OF THE DOOR TO THE INTERSECTING WALL.

U. CONTRACTOR MUST VERIFY THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES AND THEIR SERVICE

CONNECTIONS WITH LOCAL UTILITY PROVIDERS, INCLUDING BUT NOT LIMITED TO:

CITY OF CHEYENNE BOARD OF PUBLIC UTILITIES

CITY OD CHEYENNE SANITATION

WYOMING COMMUNITY GAS

BLACK HILLS ENERGY

CTW ELECTRIC

XCEL ENERGY

CHEYENNE LIGHT FUEL & POWER

V. CONTRACTOR MUST COORDINATE SIZE, LOCATIONS AND NUMBER OF ALL ROOF OPENINGS AND ROOF ACCESSORIES WITH ALL OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL

DRAWINGS.

W. LOCATIONS AND SIZES OF ALL CONCRETE MECHANICAL AND ELECTRICAL PADS MUST BE COORDINATED BY THE MECHANICAL AND ELECTRICAL CONTRACTORS WITH THE SELECTED EQUIPMENT MANUFACTURER AND/OR SUPPLIER.

LOCATIONS AND ARE TO BE APPROVED BY THE VHA COR PRIOR TO PROCEEDING WITH THE WORK.

X. EXCEPT AT FIRE-RATED PARTITIONS, ALL WALL AND COLUMN GYPSUM BOARD FACING MUST BE HELD AT 5/8" BELOW

STRUCTURE, UNLESS DETAILED OR NOTED OTHERWISE.

Y. AT ALL TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING, BOTTOM TO BE LOCATED AT 4" AFF VERIFY LENGTHS AND

LOCATIONS WITH ELECTRICAL DRAWINGS; REFER TO APPLICABLE SPECIFICATIONS.

Z. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 1'-6" OF THE FLOOR, AND WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF A DOOR, ETC, MUST BE SAFETY GLAZING AS APPROVED FOR IMPACT BY APPLICABLE BUILDING

CODES, AND MUST BE LABELED AS SUCH.

AA. ALL CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM SLAB OR TILE FLOOR (FINISHED FLOOR) TO FINISH

CEILING.

BB. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING

SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.

CC. ALL CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER MUST HAVE THE SAME FINISHES AS ADJOINING

SPACES.

DD. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD AS REQUIRED FOR THE MOUNTING OF ALL TOILET ACCESSORIES, MILLWORK, CASEWORK, AV EQUIPMENT, MEP ITEMS AND RADIOLOGY EQUIPMENT, ETC.; REFER TO

APPLICABLE SPECIFICATIONS.

EE. REFER TO SPECIFICATIONS FOR ALL REQUIRED TESTING AND INSPECTIONS.

GENERAL NOTES

CEILING HEIGHT

SUPPLY

RETURN / EXHAUST

TYPICAL LIGHT FIXTURE

SIZE VARIES

9'-0"

REFLECTED CEILING PLAN

SYMBOLS LEGEND

OS

LINEAR PENDANT LIGHT

INDUSTRIAL STRIP LIGHT

CAN LIGHTACCESS PANEL

OCCUPANCY SENSOR

FIRE EXIT SIGN

SPRINKLER HEAD

A

ROOM NAME

W3

A3

SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE

ELEVATION CALLOUT EXAMPLE

DETAIL CALLOUT EXAMPLE

SECTION CALLOUT EXAMPLE

SECTION, DETAIL, OR ELEVATION

SYMBOL IDENTIFIERS

DETAIL NAME

LETTER OR NUMBER

DESIGNATOR

DRAWING

SEQUENCE NUMBER

INDICATES WHERE

TITLE IS LOCATED

ONE OR TWO CHARACTER

DISCIPLINE DESIGNATOR (MAY

NOT BE PRESENT IF CALLOUT

AND TITLE ARE ON DRAWINGS

WITHIN THE SAME DISCIPLINE)

AE101

DOOR

NUMBER TAG

WALL

TYPE TAG

WINDOW

TYPE TAG

CENTER LINE

COLUMN

BUBBLE

ROOM TAG

MATCH LINE

DETAIL NUMBER

ON SHEET

SHEET NUMBER

DETAIL NUMBER

ON SHEET

SHEET NUMBER

NEW LINE TYPE

EXISTING LINE TYPE

DEMO LINE TYPE

DEMO HATCH TYPE

1 HOUR FIRE RESISTANCE RATED LINE

1 HOUR FIRE RATED,

SMOKE BARRIER LINE

2 HOUR FIRE RATED,

SMOKE BARRIER LINE

3 HOUR FIRE RATED,

SMOKE BARRIER LINE

4 HOUR FIRE RATED,

SMOKE BARRIER LINE

View Name

1/8" = 1'-0"

2 HOUR FIRE RESISTANCE RATED LINE

3 HOUR FIRE RESISTANCE RATED LINE

4 HOUR FIRE RESISTANCE RATED LINE

AE101

AE101

A

A101

FLOOR PLAN SYMBOLS LEGEND

SS

SS

SS

SS

AE101

EXTERIOR

INTERIOR

XX KEYNOTE, OBJECT

KEYNOTE SURFACE

REVISION TAG1

DRAWING SCALE

MATERIAL

KEYNOTE

FIXTURE

KEYNOTE

05.34G

10.28A

XX

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

GI002

GENERAL INFORMATION AND

ABBREVIATIONS

CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

TOC TOP OF CURB / CONCRETE

TOD TOP OF DECK

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOR TOP OF ROOF

TOS TOP OF STEEL

TOW TOP OF WALL

TPO THERMOPLASTIC POLYOLEFIN

TRANSF TRANSFORMER

TV TELEVISION

TYP TYPICAL

TZ TERRAZZO

U

UH UNIT HEATER

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

V

VB VAPOR BARRIER (VPR BR)

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VHA VETERANS HEALTH ADMINISTRATION

VHA VETERAN'S HEALTH ADMINISTRATION

VIF VERIFY IN FIELD

VNR VENEER

VTR VENT THROUGH ROOF

VWC VINYL WALLCOVERING

W

W WEST, WIDTH, WIDE

W/ WITH

W/IN WITHIN

W/O WITHOUT

WB WOOD BASE

WC WATER CLOSET

WD WOOD

WDW WINDOW

WH WALL HYDRANT / WATER HEATER

WP WATERPROOFING / WORKING POINT

WR WEATHER RESISTANT

WSF WELDED SEAM SHEET FLOORING

WT WEIGHT

WWF WELDED WIRE FABRIC

X, Y, Z, MISC

& AND

@ AT

XPS EXTRUDED POLYSTYRENE

YD YARD

PR PAIR

PREFAB PREFABRICATE (D)

PREFIN PREFINISHED

PRELIM PRELIMINARY

PREP PREPARE (D)

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT / PORCELAIN TILE

PTN PARTITION

PVC POLYVINYL CHLORIDE

PVG PAVING

Q

QT QUARRY TILE

QTB QUARRY TILE BASE

QTY QUANTITY

R

R RISER / RADIUS

RA RETURN AIR

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFRIGERATOR

REINF REINFORCE (D), (ING)

REQD REQUIRED

REV REVISED/ REVISION

RFG ROOFING

RH RIGHT HAND

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RR RESTROOM

RSF RESILIENT SHEET FLOORING

RTU ROOF TOP UNIT

S

S SOUTH

SAN SANITARY SEWER

SC SOLID CORE

SCH SCHEDULE

SCRN SCREEN

SECT SECTION

SF SQUARE FOOT (SQFT)

SHT SHEET

SIM SIMILAR

SOG SLAB ON GRADE

SPEC SPECIFICATION (S)

SPKLR SPRINKLE

SPKR SPEAKER

SQ SQUARE

SS STAINLESS STEEL

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURE / STRUCTURAL

SUSP SUSPENDED

SY SQUARE YARD (SQ YD)

SYM SYMMETRICAL / SYMBOL

SYS SYSTEM

T

T TREAD

TEL TELEPHONE

TEMP TEMPORARY / TEMPERED

TG TONGUE & GROOVE

THK THICK (NESS)

THRU THROUGH

TKBD TACK BOARD

TO TOP OF

LAV LAVATORY

LBS POUNDS

LF LINEAR FOOT (FEET)

LH LEFT HAND

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LPT LOW POINT

LRG LARGE

LT LIGHT

LTG LIGHTING

LVR LOUVER

LVT LUXURY VINYL TILE

LWC LIGHTWEIGHT CONCRETE

M

MAS MASONRY

MAX MAXIMUM

MBR MEMBER

MDF MEDIUM DENSITY FIBERBOARD

MECH MECHANICAL

MED MEDIUM

MEMB MEMBRANE

MEP MECHANICAL, ELECTRICAL, PLUMBING

MFG MANUFACTURING

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MOD MODULAR

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

N

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NSF NET SQUARE FEET

NTS NOT TO SCALE

O

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD / OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

OZ OUNCE

P

PA PUBLIC ADDRESS

PACU POST-ANESTHESIA CARE UNIT

PB PUSH BUTTON

PC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PERF PERFORATE (D)

PERM PERMANENT

PERP PERPENDICULAR

PL PLATE / PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLUMB PLUMBING

PLYWD PLYWOOD

PNL PANEL

POLY POLYETHYLENE

FRMG FRAMING

FRP FIBER REINFORCED PANEL

FS FLOOR SINK

FT FOOT/ FEET

FTG FOOTING

FUR FURRING

FUT FUTURE

G

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCED CONCRETE

GL GLASS / GLAZING

GOVT GOVERNMENT

GPM GALLON PER MINUTE

GSF GROSS SQUARE FEET

GWB GYPSUM WALL BOARD

GYP GYPSUM

H

H HIGH

HB HOSE BIBB

HC HOLLOW CORE

HD HEAD

HDBD HARDBOARD

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HK HOOK

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HS HIGH STRENGTH

HT HEIGHT

HTG HEATING

HTR HEATER

HVAC HEATING / VENTILATING / AIR CONDITIONING

HW HOT WATER

HWH HOT WATER HEATER

HYD HYDRANT

I

IBC INTERNATIONAL BUILDING CODE

ICRA INFECTION CONTROL RISK ASSESSMENT

ICU INTENSIVE CARE UNIT

ID INSIDE DIAMETER

ILSM INTERIM LIFE SAFETY MEASURES

IN INCH

INCL INCLUDE (D), (ING)

INFO INFORMATION

INST INSTALL / INSTALLATION

INSUL INSULATE / INSULATION

INT INTERIOR

INV INVERT

J

JAN JANITOR

JB JUNCTION BOX

JST JOIST

JT JOINT

K

KIT KITCHEN

KO KNOCKOUT

KPL KICK PLATE

L

L LONG / LENGTH

LAB LABORATORY

LAM LAMINATE (D)

CS COUNTERSINK

CSMT CASEMENT

CT CERAMIC TILE

CU CUBIC

CW COLD WATER

D

DBL DOUBLE

DEMO DEMOLISH / DEMOLITION

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DH DOUBLE HUNG

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DMT DEMOUNTABLE

DN DOWN

DR DOOR

DS DOWNSPOUT

DTL DETAIL

DWG DRAWING

E

E EAST

EA EACH

EF EXHAUST FAN

EJ EXPANSION JOINT

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EP ELECTRICAL PANELBOARD

EQ EQUAL

EQUIP EQUIPMENT

ESC ESCALATOR

EST ESTIMATE

ETR EXISTING TO REMAIN

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION / EXPOSED

EXT EXTERIOR

F

FA FIRE ALARM

FAB FABRIC

FB FACE BRICK

FBO FURNISHED BY OWNER

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FF&E FIXTURES, FURNITURE & EQUIPMENT

FFE FINISH FLOOR ELEVATION

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIN FINISH / FINISHED

FIXT FIXTURE

FLG FLOORING

FLR FLOOR

FLUOR FLUORESCENT

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOG FACE OF GYPSUM BOARD / WALL

FOM FACE OF MASONRY

FOS FACE OF STUDS

FR FIRE RATED

A

ABA ARCHITECTURAL BARRIERS ACT

AC AIR CONDITIONING

ACP ACOUSTICAL CEILING PANEL

ACST ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADJ ADJUSTABLE / ADJACENT

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

AP ACCESS PANEL

APC ARCH PRECAST CONCRETE

APPROX APPROXIMATE

ARCH ARCHITECT / ARCHITECTURAL

ATTEN ATTENUATION

AUTO AUTOMATIC

AV AUDIO / VISUAL

AVG AVERAGE

AWP ACOUSTICAL WALL PANEL

B

BD BOARD

BITUM BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BM BENCH MARK / BEAM

BO BOTTOM OF

BOC BACK OF CURB

BOT BOTTOM

BRG BEARING

BRK BRICK

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BVL BEVELED

C

C COURSE

CAB CABINET

CAP CAPACITY

CB CATCH BASIN

CCTV CLOSED CIRCUIT TV

CF CUBIC FEET

CFM CUBIC FEET PER MINUTE

CG CORNER GUARD

CI CAST IRON

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLOS CLOSET

CLR CLEAR / CLEARANCE

CMP CORRUGATED METAL PIPE

CMT CERAMIC MOSAIC TILE

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

COMB COMBINATION

CONC CONCRETE

CONN CONNECTION / CONNECT

CONST CONSTRUCT / CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S REPRESENTATIVE

CORR CORRIDOR / CORRUGATED

CP CONCRETE PIPE

CPT CARPET

ARCHITECTURAL ABBREVIATIONS

WITH THEIR BIDS CONTRACTOR SHALL SUBMIT ALTERNATES LINE ITEMS FOR ELIMINATING/

MODIFYING THE FOLLOWING SCOPE DEPICTED ON THE CONSTRUCTION DOCUMENTS:

ALTERNATE 1:

REPLACEMENT OF GLASS SLIDING DOORS TO ICU-1 AND ICU-3. IF THIS ALTERNATE IS ACCEPTED THE

CONTRACTOR WILL INSTEAD REFURBISH THE EXISTING DOORS AND TRACK AND PROVIDE NEW

SEALS ON THEM.

ALTERNATE 2:

REPLACEMENT OF THE CEILING MOUNTED PATIENT LIFTS IN ROOMS ICU-1 AND ICU-3. IF THIS ALTERNATE IS ACCEPTED THE CONTRACTOR SHALL INSTEAD REINSTALL THE EXISTING PATIENT LIFTS IN ICU-1 AND ICU-3 AND MODIFY THE TRACK AND ASSOCIATED SUPPORT SYSTEM FOR THE ICU-1 LIFT AS NEEDED FOR THE ROOM RECONFIGURATION. CONTRACTOR SHALL LOAD TEST AND

CERTIFY PATIENT LIFTS.

ALTERNATE 3:

INSTALLATION OF A PATIENT LIFT IN PACU-4.

ALTERNATES

CLEAR

FLOOR

SPACE

1 1/2" O.D. (SS OR CHROME)

GRAB BAR SUPPORTS

250 LBS FORCE (TYP.)

4'

1"

F O

R F

LO

O

R M

T D

. W .C

4'

F

O R

W A

LL

H

U N

G W

.C

5' - 0"

1'-4" MIN.

1' - 6" MAX.

VERTICAL GRAB

BAR 18" MIN.

NOTE: PARTITION DOOR IS

TO BE LOCATED OPPOSITE

OF WC LOCATION

TOILET

PARTITION

1 1/2" O.D. (SS OR CHROME)

GRAB BAR SUPPORTS

250 LBS FORCE (TYP.)

2'

C

LE

A R

3'

M

IN

4'

1"

F O

R F

LO

O

R M

T D

. W .C

4'

F O

R W

A

LL

M T

D . W

.C

5' - 0" CLEAR

1' - 6" MAX.

1' -4" MIN. 2' - 0" 1' - 6"

M A

X

1'

3'

M

IN

4'

M

IN

VERTICAL GRAB

BAR 18" MIN.

(TYP.)

4"

MIN.

1' - 0"

MIN.

1' - 6"

PULL SIDE

PUSH SIDE

M A

X

8"

M

IN

5'

M

IN

4'

MIN.

2' - 0"

MIN.

2' - 0"

PULL SIDE

PUSH SIDE

M

IN

4'

M

IN

4'

1' - 10"

MIN.

3' - 0"

PULL SIDE

PUSH SIDE

M

IN

4'

M

IN

5'

MIN.

1' - 10"

MIN.

3' - 6"

PULL SIDE

PUSH SIDE

M

IN

4'

M

IN

4'

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

APPROACH

APPROACH

CENTERLINE OF BRACKET

FIRE EXTINGUISHER

& STANDARD BRACKET

4'

M A

X

CENTERLINE OF CABINET

HANDLE OR CENTERLINE

OF FE HANDLE IF HUNG

INSIDE CABINET

4'

M A

X

FIRE EXTINGUISHER

CABINET

CLEAR

FLOOR

SPACE

11" MIN.

9" M

IN

2'

M

IN

2' - 1" MAX.

1' - 5" MIN.

T O

P O

F S

IN

K

R

IM

O R

C O

U N

T E

R 2'

0" M

A X

T O

H

IG

H E

R O

F

PLAN

SECTION

6" MAX.

8" MIN.

LINE OF WHEELCHAIR

2' - 6"

4'

LIGHT SWITCH

4'

M A

X

MAX.

1' - 0"

2"

THERMOSTAT

1'

M

IN

RECEPTACLE

SANITARY

NAPKIN

DISPOSAL

TOILET PAPER

DISPENSER

1'

M

IN

SOAP DISPENSER

( 4" MAX. PROJ. )

MIRROR

SANITARY

NAPKIN

DISPENSER

INTEGRAL WASTE

DISPOSAL WHERE

APPLICABLE

( 4" MAX. PROJ. )

TOWEL

DISPENSER

PAPER TOWEL

DISPENSER

( 4" MAX. PROJ. )

BABY

CHANGING

STATION

PASS-THRU

PAPER TOWEL

DISPENSER

( 4" MAX. PROJ. )

R E

F

LE

C T

IV

E

S U

R F

A C

E

3'

M A

X . T

O B

O

4'

M A

X

4'

M A

X

S E

E N

O T

E

R E

F

LE

C T

IV

E

S U

R F

A C

E

6'

M

IN

. T O

T O

P O

F

1 1/2" O.D. (SS OR CHROME)

GRAB BAR SUPPORTS

250 LBS FORCE (TYP.)

T O

T .O

. B A

R

2'

T O

B .O

. O P

E N

IN

G

1' -6

M

IN

WATER CLOSET FLUSH

HANDLES SHALL BE

LOCATED ON THE

TRANSFER SIDE OF THE

STOOL

2' - 0" MIN.

MIN.

1' - 0"

1' - 6" MAX.

1' - 4" MIN.

DISPENSER

1 1/2" O.D. ( SS OR

CHROME )

GRAB BAR SUPPORTS

250 LBS FORCE (TYP.)

3' - 6" MIN.1' - 0" MAX.

T O

T .O

. B A

R

2'

T O

1 1/2"

T .O

. O P

E N

IN

G

4' -0

M

A X

.DISPENSER

1/

2"

7" TO 9" B

.O

. O P

E N

IN

G

1' -6

M

IN

4' - 6" MIN.

MAX.

3' - 0"

2'-0" MIN.

3'-0" MAX.

1'

ACCESSIBILITY GUIDELINES

A. ALL DIMENSIONS ARE MEASURED FROM THE FINISH FLOOR AND THE FINISH

WALL, UNLESS NOTED OTHERWISE. ACCESSIBILITY GUIDELINES ARE BASED

ON “PG-18-13 VA BARRIER FREE DESIGN STANDARD” AND THE

“ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS).”

B. ACCESSIBLE UNOBSTRUCTED REACH RANGES:

1. FORWARD REACH = 15" MIN TO 48" MAX

2. SIDE REACH = 15" MIN TO 48" MAX

C. DOOR HARDWARE (TO CENTER OF HARDWARE):

STANDARD MOUNTING HEIGHTS:

1. PUSH PLATES = 42"

2. PULL HANDLES = 42"

3. KNOBS / LEVERS = 40"

4. PANIC DEVICE = 42" CL OF BAR

5. KICKPLATES:

a. WIDTH = DOOR WIDTH MINUS 2"

b. CENTER HEIGHT = 16" FROM BO DOOR

6. THRESHOLDS:

a. STANDARD = 1/2" MAX

b. EXTERIOR SLIDING DOORS = 3/4" MAX

D. COUNTERTOPS (TO SINK RIM / COUNTERTOP):

1. ACCESSIBLE = 28" MIN TO 34" MAX

E. WATER CLOSETS (TO TOP OF SEAT):

1. STANDARD = 14" TO 15"

2. ACCESSIBLE (TO TOP OF SEAT) = 17" TO 19"

3. ACCESSIBLE FLUSH CONTROLS = 44" MAX

F. LAVATORIES (TO SINK RIM / COUNTERTOP):

1. STANDARD = 36" MAX

2. ACCESSIBLE = 34" MAX (29" MIN CLEAR KNEE SPACE)

G. MIRRORS:

1. TO B/O REFLECTIVE SURFACE:

a. STANDARD = VARIES

b. ACCESSIBLE = 40" MAX

2. TO T/O REFLECTIVE SURFACE:

a. STANDARD = VARIES

b. ACCESSIBLE = 74" MIN

H. GRAB BARS - ACCESSIBLE (TO TOP OF BAR):

1. WATER CLOSETS = 33" MIN TO 36" MAX

2. SHOWERS = 33" MIN TO 36" MAX (FROM BO SHOWER)

3. BATHTUBS:

a. TOP BAR = 33" MIN TO 36" MAX

b. BOTTOM BAR = 9" ABOVE TOP OF TUB

I. SHOWER HEADS (FROM FLOOR TO HEAD):

1. STANDARD = 72" TO 84"

2. ACCESSIBLE = SPRAY UNIT WITH HOSE 60" LONG MIN

3. ACCESSIBLE FIXED SHOWER HEAD = 48" AFF

J. TOILET PAPER DISPENSER (TO CL OF OUTLET):

1. STANDARD = 24"

2. ACCESSIBLE = 15" MIN TO 48" MAX

K. WALL MOUNTED SOAP DISPENSER (TO CL OF PUSH BUTTON):

1. STANDARD = 40"

2. ACCESSIBLE = VARIES (REFER TO OBSTRUCTED AND UNOBSTRUCTED

REACH RANGES)

3. ACCESSIBLE SIDE REACH = 46" MAX ABOVE SINK IN COUNTER

L. PAPER TOWEL DISPENSER / WASTE RECEPTACLE (TO TOWEL SLOT):

1. STANDARD = 40" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN

3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN

M. TOILET SEAT COVER DISPENSERS (TO OPENING):

1. STANDARD = 40" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN

3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN

N. COAT HOOKS:

1. STANDARD = 68"

2. ACCESSIBLE = 48" MAX

O. CHALKBOARDS, TACKBOARDS & MARKERBOARDS:

1. STANDARD = 32" TO 39" (TO BO BOARD OR CHALK TRAY)

2. STANDARD = 80" (RECOMMENDED, TO TOP OF BOARD)

P. THERMOSTATS & CONTROL DEVICES (TO TOP):

1. ACCESSIBLE FORWARD REACH = 48" MAX

2. ACCESSIBLE SIDE REACH = 48" MAX

Q. LIGHT SWITCHES & CARD READERS (TO CL):

1. LOCATE 6" FROM DOOR JAMB

2. ACCESSIBLE = 48" MAX

R. CONVENIENCE RECEPTACLES / ELECTRICAL / TELEPHONE / DATA (TO CL):

1. STANDARD = 18"

2. ACCESSIBLE = 15" MIN

S. EXIT LIGHTS - WALL MOUNTED:

1. 2" BELOW CEILING

2. 2" MIN ABOVE DOOR FRAME EQUAL SPACE FROM CEILING TO TOP OF

FRAME

T. FIRE EXTINGUISHERS (TO TOP UNLESS NOTED OTHERWISE):

1. GROSS WT 40 LBS OR LESS = 60" MAX

2. GROSS WT MORE THAN 40 LBS = 42" MAX

3. ACCESSIBLE = 40" MAX (TO BO CABINET)

U. FIRE ALARM PULL STATION (TO LEVER):

1. STANDARD = 48" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX

3. ACCESSIBLE SIDE REACH = 48" MAX

V. SMOKE AND / OR HEAT DETECTORS:

1. STANDARD = CEILING HEIGHT

W. HORN / SPEAKER / VISUAL SIGNALS:

1. STANDARD = 80" AFF OR 6" BELOW CEILING - WHICHEVER IS LOWER

X. ROOM SIGNAGE (TO CL):

1. STANDARD = 60" HIGH AFF & WITHIN 18" OF LATCH SIDE OF DOOR

GENERAL NOTES

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

GI003

ACCESSIBILITY STANDARDS CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

1/2" = 1'-0"

ACCESSIBLE CLEAR FLOOR SPACE

B1 1/2" = 1'-0"

TYP. DOOR JAMB & DOOR APPROACH CLEARANCES

B4

1/2" = 1'-0"

FIRE EXTINGUISHER/ FEC

F71/2" = 1'-0"

SWITCH @ DOOR

F6

1/2" = 1'-0"

TOILET ACCESSORIES

E5

1/2" = 1'-0"

TYPICAL FIXTURE MOUNTING HEIGHTS

C5

8'4'2'1'6"0'

LEGEND

CODE INFORMATION

BUILDING CONSTRUCTION TYPE: TYPE II-FR -- 1985 UBC

(TYPE I-B -- 2018 IBC)

BUILDING OCCUPANCY: BASEMENT = EXISTING HEALTH CARE (LSC)

FIRST FLOOR = EXISTING HEALTH CARE (LSC)

SECOND FLOOR = EXISTING HEALTH CARE (LSC)

BUILDING IS FULLY SPRINKLERED

PROJECT DESCRIPTION: RENOVATION OF MULTIPLE SPACES, HOWEVER THERE ARE

NO CHANGES TO OCCUPANCY CLASSIFICATION OR OR OCCUPANT LOAD.

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL

CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE

TECHNICAL INFORMATION LIBRARY (TIL) (WWW.CFM.VA.GOV/TIL/)

• INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY

REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)

• NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)

• NFPA NATIONAL FIRE CODES, WITH THE EXCEPTION OF NFPA 5000 AND NFPA

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• INTERNATIONAL PLUMBING CODE

• ASME CODE FOR PRESSURE PIPING

• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS

• INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)

• ENERGY POLICY ACT OF 2005 (EPAct)

• EXECUTIVE ORDER13423: STRENGTHENING FEDERAL ENVIRONMENTAL,

• ENERGY, AND TRANSPORTATION MANAGEMENT

• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE

GENERAL REQUIREMENTS SECTION 01 00 00 OF THE VA MASTER

• CONSTRUCTION SPECIFICATION

• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY -- ASHRAE STANDARD

62.1-2004

LOCAL CODES:

AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL

IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS,

BUILDING PERMITS, INSPECTIONS, FEES, ETC.).VA MUST FUNCTION AS THE

AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO

GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.

HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED

PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA

DOES NOT PAY FOR REVIEW OR INSPECTION FEES.

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION

FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS,

INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY,

SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION.

VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS

REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION

REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL

COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND

DOCUMENTS REFERENCED THEREIN.

DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED

THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF

THE IBC OR AS OTHERWISE ADDRESSED IN THE PROGRAM GUIDE PG-18-3. FOR

DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101

OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101

OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY

(THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND

VA REQUIREMENTS -- SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS

AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE

CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE VHA COR. THE

RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING

JURISDICTION FOR VHA TO ENSURE A CONSISTENCY SYSTEM WIDE.

APPLICABLE CODES AND STANDARDS

KEY PLAN

N o rt h

I-CA

I-B

I-A

I-C

BLDG 45

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

GI004

STATEMENT OF CONDITIONS CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

FIRE RESISTANCE RATINGS

Fire Barriers 2-Hour : 2FB 1-Hour : 1FB Smoke Barriers 1-Hour : 1SB Smoke Partitions Resists the Passage of Smoke

2FB2FB2FB

RPSRPSRPS

1FB1FB1FB

1SB1SB1SB

Exit Stairway

Exit

Exit Access

Exit Access Corridor - Public

ES

MEANS OF EGRESS

Exit Access Corridor - Staff

EX EX

EA EA

HAZ Hazardous Area

Vertical Opening (Shaft or Hoistway)VO

LVDm

O S

OD

O D

OS2LVD

OS2

LVD

O D

LV

D

LV

D m

C

D

E

A

B

108 97

STAIR

ELEC

VAULTICU 4ICU 5ICU 6PACU 3

NURSING

STATION

N MEDS

EQUIP

OFFICETOILET

OFFICE

EQUP

STOR

HAC

F TLTM TLT

OFFICE

NURSING

LOUNGE

NURSING

LOCKER

RM

SOILED

UTIL

HAC

IV RM

NURSING

BTH/

SHOWER

SURGERY

WAITING

RM

TOILET

NURSE

TLT

CLEAN

UTIL

PACU 2

NURSE

STATION

CORRIDOR

OFFICE

CORRIDOR

NURSING

W. SUPP

MEDS

ANTE RM

OFFICE

B2-20A

ANTE RM

B2-20

ICU 3

B2-49A

PACU 4 -

TOILET

B2-49

PACU 4

B2-47

PACU 4 -

ANTE RM

B2-14

NURSE

CONSULT

B2-12

NURSE

SUP.

MECHANICAL

SHAFT

C

D

E

A

B

87654

TELEPHONE

CONTROL

CORRIDOR

WAITING

ROOM

STAIRS ELEV 6ELEV 7

SERV

ELEV

SERV

ELEV

MECHANICAL

SHAFT

32'16'8'4'2'0'

North1/8" = 1'-0"

SECOND FLOOR - FLOOR PLAN - RATED WALLS

1/8" = 1'-0"

PENTHOUSE - FLOOR PLAN - RATED WALLS

EAC-S

SUITE

1,761 sf

RP

S

RPSRPS

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RPS

RP

S

RP

S

RP

S

RP

S

RP

S

RPSRPSRPSRPS

RP

S

RP

S

RP

S

1FB 1FB 1FB

1F B

1F B

1F B

1F B

1FB1FB

1F B

1F B

1FB

1F B

1F B

HAZ

73 sf

77 sf 114 sf 81 sf

HAZ

93 sf

1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB

1FB

1FB

1FB

1FB

1FB1FB1FB1FB1FB1FB1FB1FB

1F B

1F B

1F B

1F B

1FB1FB1FB

1F B

1F B

1F B

1F B

1FB 1FB 1FB 1FB

1FB

1FB

1FB

1FB

2FB 2FB 2FB 2FB

2F B

2F B

2F B

2F B

2FB2FB2FB2FB

2F B

2F B

2F B

2F B

2FB2FB2FB

2F B

2F B

2F B

2F B

2F B

2F B

2F B

RPSRPSRPSRPSRPSRPSRPSRPSRPSRPSRPSRPSRPS

RPS RPS

RP

S

RP

S

RP

S

RP

S

RP

S

RPSRPS

RPS RPS

RP

S

RP

S

RP

S

RP

S

RPSRPSRPSRPSRPSRPSRPSRPSRPSRPS

RP

S

RP

S

RPSRPSRP

S

RP

S

RPSRPSRPSRPSRPSRPS

RP

S

RP

S

RP

S

RPS RPS

RP

S

RP

S

RP

S

1F B

1F B

1F B

1FB 1FB 1FB

1F B

1F B

1F B

1FB 1FB

1F B

1F B

1F B

1FB

1F B

1F B

1F B

HAZ

111 sf

HAZ

65 sf

RPSRPS

RPSRPS

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

EAC-P

EX

EAEA

EA

HAZ

127 sf

RP

S

RP

S

RP

S

RPS RPS

RP

S

RP

S

RP

S

1FB1FB1FB1FB1FB

1F B

1F B

1FB 1FB 1FB 1FB 1FB

EAC-P

VOVO

VO VO

VO

VO

VO

VO

VO

VO

2FB 2FB 2FB

2F B

2F B

2F B

2F B

2F B

2FB2FB2FB2FB

2F B

2F B

2F B

2F B

2F B

2FB 2FB 2FB 2FB 2FB

2F B

2F B

2F B

2F B

2FB2FB2FB2FB2FB

2FB

2FB

2FB

2FB

2FB 2FB 2FB 2FB

2F B

2F B

2F B

2FB2FB2FB2FB

2F B

2F B

2F B

2FB 2FB

2F B

2F B

2FB2FB

2F B

2F B

2FB

2F B

2FB

2F B

2FB

2F B

2FB

2F B

2F B

2FB 2FB

2F B

2F B

2F B

2F

B2FB2FB2FB2FB2FB2FB

2F B

2F B

2F B

ES

ES

EAC-S

2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB

2F B

2F B

2F B

2F B

2F B

2F B

2F B

E A

E X

RPSRPSRPS

RP

S

RP

S

RPS RPS RPS

RP

S

VO

2F B

2F B

2FB 2FB 2FB

2F

B 2F

B

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RP

S

RPSRPSRPS

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2FB

2-HOUR FIRE-RESISTANT RATED DUCT

WRAP FOR NEW EXHAUST PENETRATING

THE 2-HOUR FLOOR CONSTRUCTION.

Z

Z

Z

STOR

HAZ

77 sf

STOR

HAZ

77 sf

SUPPLY

STOR

HAZ

77 sf

SUPPLY

81 sf

HAZ

77 sf

81 sf

HAZ

77 sf

81 sf

HAZ

77 sf

EQUIP

Z

STOR

HAZ

77 sf 81 sf

HAZ

77 sf

81 sf

HAZ

77 sf

PACU 44

STAMP:

1FBFB 1FB

NOTES - PROJECT PHASING

IN ORDER TO LIMIT DISRUPTION OF ICU/ PACU WARD OPERATIONS AND CONTAIN AIR-

BORNE DUST & CONTAMINATION FROM CONSTRUCTION ACTIVITIES, ALL WORK UNDER

THIS CONTRACT SHALL BE DIVIDED INTO AREAS AS IDENTIFIED IN PHASING PLAN

DRAWINGS. AN INFECTION CONTROL RISK ASSESSMENT SHALL BE PERFORMED TO

DETERMINE EXTENTS OF CONSTRUCTION ACTIVITIES CONTAINMENT BARRIERS.

THE CONTRACTOR SHALL PERFORM WORK IN SEQUENCE AS SHOWN. ALL SCOPED WORK

WITHIN PROJECT PHASE MUST BE COMPLETED AND APPROVED BY VHA COR PRIOR TO

START OF WORK IN THE SUBSEQUENT PHASE.

EXACT SEQUENCING OF DEMOLITION AND CONSTRUCTION ACTIVITIES WITHIN PROJECT

PHASES SHALL BE DETERMINED BY THE CONTRACTOR AND AS SUCH ARE TO BE

CONSIDERED MEANS AND METHODS. THE EXTENTS AND SEQUENCING OF CONSTRUCTION

ACTIVITIES SHALL BE CONFIRMED AND COORDINATED WITH THE VHA COR. ALL

ASSOCIATED MEP, FIRE, LOW VOLTAGE/COMMUNICATIONS ITEMS TO BE COORDINATED BY

CONTRACTOR WITH VHA COR.

A GENERAL DESCRIPTION OF EACH PHASE IS AS FOLLOWS. WORK ON REFER TO

DRAWINGS AND SPECIFICATIONS FOR MORE INFORMATION.

PROJECT PHASING LEGEND

EXISTING TO REMAIN OPERATIONAL

WALL - EXISTING TO REMAIN

WALL - DEMO

WALL - NEW

ROOM TAG - EXISTING ROOM

ROOM TAG - NEW OR RECONFIGURED

XXXX (E)

XXXX (N)

MECH

WORK

O.H.

NURSE SUP. (E)

NURSE CONSULT (E)

ICU 1 (E)

ICU 3 (E)

ANTE RM (E)

MECH

WORK

O.H.

NURSE SUP. (N)

NURSE CONSULT (N)

ANTE RM (N)

ICU 1 (E)

ICU 3 (E)

ANTE RM (E)

NURSE SUP. (E)

NURSE CONSULT (E)

ICU 1 (E)

ICU 3 (E)

ANTE RM (E)

PACU 4 (E) ANTE RM (E) TOILET (E)

PACU 4 (E) ANTE RM (E) TOILET (E)

MECH WORK O.H.

PACU 4 (E) ANTE RM (E) TOILET (E)

MECH WORK O.H.

PACU 4 (E) ANTE RM (E) TOILET (E)

MECH

WORK

O.H.

PACU 4 (E) ANTE RM (E) TOILET (E)

PACU 4 (E) ANTE RM (E) TOILET (E)

MECH

WORK

O.H.

NURSE SUP. (N)

NURSE CONSULT (N)

ANTE RM (N)

ICU 1 (E)

ICU 3 (E)

ANTE RM (E)

NURSE SUP. (N)

NURSE CONSULT (N)

ANTE RM (N)

ICU 1 (E)

ICU 3 (E)

ANTE RM (E)

NURSE SUP. (E)

NURSE CONSULT (E)

ICU 1 (E)

ICU 3 (E)

ANTE RM (E)

KEY PLAN

N o rt h

I-CA

I-B

I-A

I-C

BLDG 45

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:2

P

M

GI005

PHASING PLAN CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

NTS

PHASE 2A - DEMOLITION

2A

NTS

PHASE 2B - CONSTRUCTION

2B

NTS

PHASE 1A - DEMOLITION

1ANTS

PHASE 3A - DEMOLITION

3A

NTS

PHASE 3B - CONSTRUCTION

3B

North

NTS

PHASE 1A - CONSTRUCTION

1B

PHASE 1A - PACU-4, ANTE ROOM & TOILET DEMOLITION:

• COVER AND PROTECT ALL WALL MOUNTED FIXTURES TO REMAIN

• DEMOLISH WALL BASE AT PERIMETER OF PACU-4 (B2-49) & ANTE-ROOM (B2-47)

• DEMOLISH ALL FLOOR FINISHES INCLUDING FLOOR TILE, LAMINATE FLOORING AND FLOOR TILE AT

PACU-4 (B2-49) & ANTE-ROOM (B2-47)

• REMOVE AND STORE EXISTING DOOR B2-49A FOR MODIFICATION AT DOOR FRAME HEAD TO

ACCOMMODATE PATIENT TRACK GATE ASSEMBLY

• REMOVE CEILING MOUNTED OVERHEAD PATIENT LIFT

• REMOVE ALL CEILING MOUNTED EQUIPMENT AND PRIVACY CURTAIN TRACKS

• REMOVE ALL SUSPENDED LIGHTING FIXTURES

• REMOVE CEILING MECHANICAL REGISTERS

• DEMOLISH ALL CEILING TILE AND GRID WITHIN SCOPE

• WALL DEMOLITION FOR NEW DOOR LOCATION AT PACU-4

• FIRE SPRINKLER HEADS ALL ROOMS WITHIN SCOPE TO REMAIN; RE: PLUMBING PLAN FOR

SPRINKLER HEAD WORK

PHASE 1B - PACU-4, ANTE ROOM & TOILET CONSTRUCTION:

• INSTALL NEW DOOR AT PACU-4/ CORRIDOR

• NEW FLOORING AT PACU-4 (B2-49) & ANTE-ROOM (B2-47)

• NEW WALL BASE AT PACU-4 (B2-49) & ANTE-ROOM (B2-47)

• DOOR B2-49A - MODIFY EXISTING DOOR FRAME & WALLS PER DETAILS B3/A62 & D3/A620 AND

REINSTALL DOOR TO ACCOMMODATE PATIENT TRACK GATE ASSEMBLY

• PATCH & PAINT ALL WALLS IN ROOMS TO BE RENOVATED, INCLUDING NEW GYP WALLS & EXISTING

PLASTER WALLS

• INSTALL BED PAN WASHER FLUSH-VALVE SYSTEM AT EXISTING TOILET

• INSTALL ALL WALL MOUNTED EQUIPMENT AS INDICATED IN PLAN

• INSTALL NEW SUSPENDED CEILING TILE, LIGHTING, MECHANICAL REGISTERS

• INSTALL/ REINSTALL CEILING MOUNTED EQUIPMENT INCLUDING SMOKE DETECTORS, WIFI ACCESS

POINTS, PRIVACY CURTAINS, ETC.

• INSTALL NEW CEILING MOUNTED OVERHEAD PATIENT LIFT

• VAV INSTALLED ABOVE CEILING AT CORRIDOR

PHASE 2A - ICU-1, NURSE CONSULT & NURSE WARD SUPPLY DEMOLITION:

• REMOVE WALL MOUNTED EQUIPMENT IN ALL ROOMS WITHIN SCOPE

• REMOVE ALL WALL MOUNTED LIGHTING FIXTURES WITHIN SCOPE

• DEMOUNT & REMOVE ALL PLUMBING FIXTURES

• DEMOLISH/ REMOVE SLIDING GLASS DOOR SYSTEM

• REMOVE CEILING MOUNTED OVERHEAD PATIENT LIFT

• REMOVE ALL CEILING MOUNTED EQUIPMENT AND PRIVACY CURTAIN TRACKS

• REMOVE ALL SUSPENDED LIGHTING FIXTURES

• REMOVE CEILING MECHANICAL REGISTERS

• DEMOLISH ALL CEILING TILE AND GRID WITHIN SCOPE

• DEMOLISH WALL BETWEEN NURSE CONSULT ROOM (B2-14) & NURSE SUPPLY (B2-12)

• WALL DEMOLITION AT CORRIDOR FOR NEW DOOR LOCATIONS FOR B2-12, B2-14, B2-16A

• DEMOLISH WALL BASE AT PERIMETER OF ALL ROOMS IN PROJECT SCOPE

• DEMOLISH ALL FLOOR FINISHES INCLUDING FLOOR TILE, LAMINATE FLOORING AND FLOOR TILE

• FIRES SPRINKLER HEADS AT ICU-1 TO REMAIN; RE: PLUMBING PLAN FOR SPRINKLER HEAD WORK

• FIRE SPRINKLER HEAD AT NURSE CONSULT TO BE RELOCATED TO ACCOMMODATE NEW PLAN

PHASE 2B - ICU-1 & ANTE ROOM CONSTRUCTION:

• CONSTRUCT WALLS

• INSTALL DOORS

• NEW SLIDING GLASS DOOR SYSTEM

• NEW FLOORING

• NEW WALL BASE

• PATCH & PAINT ALL WALLS IN ROOMS TO BE RENOVATED, INCLUDING NEW GYP WALLS & EXISTING

PLASTER WALLS

• NEW WALL WAINSCOTING TILE AT TOILET & LAVATORY SURROUND

• INSTALL NEW TOILET

• INSTALL LAVATORY AT NEW ANTE-ROOM

• INSTALL ALL WALL MOUNTED EQUIPMENT

• NURSE CALL CERTIFIED INSTALLER TO PULL NEW HOME RUNS FOR RELOCATED NURSE CALL

DEVICES

• INSTALL NEW SUSPENDED CEILING TILE, LIGHTING, MECHANICAL REGISTERS

• INSTALL/ REINSTALL CEILING MOUNTED EQUIPMENT INCLUDING SMOKE DETECTORS, WIFI ACCESS

POINTS, PRIVACY CURTAINS, ETC.

• INSTALL NEW CEILING MOUNTED OVERHEAD PATIENT LIFT

• VAV INSTALLED ABOVE CEILING AT CORRIDOR

PHASE 3A - ICU-3 & ANTE ROOM DEMOLITION:

• REMOVE WALL MOUNTED EQUIPMENT IN ALL ROOMS WITHIN SCOPE

• REMOVE ALL WALL MOUNTED LIGHTING FIXTURES WITHIN SCOPE

• DEMOUNT & REMOVE ALL PLUMBING FIXTURES

• DEMOUNT & REMOVE BED PAN WASH SINK AT ANTE ROOM

• DEMOLISH/ REMOVE SLIDING GLASS DOOR SYSTEM

• REMOVE CEILING MOUNTED OVERHEAD PATIENT LIFT

• REMOVE ALL CEILING MOUNTED EQUIPMENT AND PRIVACY CURTAIN TRACKS

• REMOVE ALL SUSPENDED LIGHTING FIXTURES

• REMOVE CEILING MECHANICAL REGISTERS

• DEMOLISH ALL CEILING TILE AND GRID WITHIN SCOPE

• DEMOLISH WALL BASE AT PERIMETER OF ALL ROOMS IN PROJECT SCOPE

• DEMOLISH ALL FLOOR FINISHES INCLUDING FLOOR TILE, LAMINATE FLOORING AND FLOOR TILE

• FIRES SPRINKLER HEADS AT ICU-3 TO REMAIN; RE: PLUMBING PLAN FOR SPRINKLER HEAD WORK

PHASE 3B - ICU-3 & ANTE ROOM CONSTRUCTION:

• NEW SLIDING GLASS DOOR SYSTEM

• NEW FLOORING

• NEW WALL BASE

• PATCH & PAINT ALL WALLS IN ROOMS TO BE RENOVATED, INCLUDING NEW GYP WALLS & EXISTING

PLASTER WALLS

• NEW WALL WAINSCOTING TILE AT TOILET & LAVATORY SURROUND

• INSTALL NEW TOILET

• INSTALL NEW LAVATORY AT ANTE-ROOM

• INSTALL ALL WALL MOUNTED EQUIPMENT

• INSTALL NEW SUSPENDED CEILING TILE, LIGHTING, MECHANICAL REGISTERS

• INSTALL/ REINSTALL CEILING MOUNTED EQUIPMENT INCLUDING SMOKE DETECTORS, WIFI ACCESS

POINTS, PRIVACY CURTAINS, ETC.

• INSTALL NEW CEILING MOUNTED OVERHEAD PATIENT LIFT

• VAV INSTALLED ABOVE CEILING AT CORRIDOR

C

D

E

A

B

108 97

B2-20A

ANTE RM

STAIR

ELEC

VAULTICU 4ICU 5ICU 6PACU 3

NURSING

STATION

N MEDS

SUPPLY

SUPPLY

STOR

EQUIP

STOR

OFFICETOILET

OFFICE

EQUP

STOR

HAC

F TLTM TLT

OFFICE

NURSING

LOUNGE

NURSING

LOCKER

RM

SOILED

UTIL

HAC

IV RM

NURSING

BTH/

SHOWER

SURGERY

WAITING

RM

TOILET

NURSE

TLT

CLEAN

UTIL

C O

R R

ID

O

R

PACU 2

NURSE

STATION CORRIDOR

OFFICE

CORRIDOR

B2-16

ICU 1

B2-20

ICU 3

B2-49A

PACU 4 -

TOILET

B2-49

PACU 4

B2-47

PACU 4 -

ANTE RM

NURSING

W. SUPP

MEDS

ANTE RM

MECHANICAL

SHAFT

B2-14

NURSE

CONSULT

B2-12

NURSE

SUP.

OFFICE

A. CONTRACTOR SHALL PROVIDE AN INFECTION CONTROL RISK ASSESSMENT BARRIER

AROUND THE PROJECT AREA CONSISTENT WITH THE CONTRACTOR'S PHASING PLAN

AS APPROVED BY THE VHA COR.

B. NO EXISTING LEAD PAINT IS ANTICIPATED TO BE FOUND IN THE PROJECT AREA.

HOWEVER, IF THE CONTRACTOR DISCOVERS OR UNCOVERS ANY SUSPECTED LEAD

PAINT OR OTHER HAZARDOUS SUBSTANCE, THE VHA COR SHALL BE NOTIFIED. WORK

WITH SUCH SUSPECTED HAZARDOUS MATERIALS SHALL CEASE UNTIL SUSPECTED

HAZARDOUS MATERIAL IS TESTED, ABATED IF NECESSARY, AND WORK AUTHORIZED

TO PROCEED BY THE VHA COR.

C. REMOVE EXISTING INTERIOR WALLS, WALL FURRING, CEILINGS, CEILING FRAMING,

INSULATION, FLOOR COVERINGS (SEE NOTE "F", BELOW), CABINETRY & DOORS,

EXTERIOR WINDOWS, STOREFRONT SYSTEMS, & OTHER ITEMS AS INDICATED ON

DEMOLITION SHEETS. CONTRACTOR TO VERIFY WALL ASSEMBLY WITHIN PROJECT

SCOPE - SOME EXISTING WALLS MAY BE LATHE & PLASTER CONSTRUCTION AND NOT

GYPSUM WALL BOARD

D. SEE MECHANICAL & ELECTRICAL & PLUMBING DRAWINGS FOR OTHER DEMOLITION

INFORMATION & REQUIREMENTS.

E. CONTRACTOR TO REMOVE, REFURBISH/ CLEAN, PROTECT AND STORE FIXTURES TO

BE REINSTALLED.

F. CONTRACTOR TO VERIFY AND COORDINATE ANY ACCESS TO AND SCHEDULE OF ANY

REQUIRED UTILITY SHUT-OFFS TO ACCOMPLISH SCOPE OF WORK WITH VHA

FOURTEEN (14) DAYS PRIOR TO THE WORK BEING DONE

G. CONTRACTOR SHALL INCLUDE ASSUMPTIONS THAT REROUTING OF EXISTING

ELECTRICAL AND OTHER INFRASTRUCTURE IN THE WALL WILL BE REQUIRED AS

WELL AS ANY FLOOR MODIFICATION REQUIRED TO PERFORM THIS WORK.

H. DO NOT REMOVE OR OTHERWISE MODIFY ANY EXISTING BUILDING STRUCTURAL

COMPONENTS UNLESS APPROVED BY THE VHA COR.

I. REMOVE ALL EXISTING FLOOR COVERINGS (E.G., FLOOR TILE, CARPET, VINYL

FLOORING, ETC.) STRIP ANY ASSOCIATED ADHESIVES AND/OR REMOVE FASTENERS

DOWN TO EXISTING CONCRETE SURFACE.

J. PRIOR TO INSTALLATION OF NEW PARTITIONS WALLS, ESTABLISH A SINGLE PLANE

DATUM (0'-0") FOR SURFACE OF FLOOR. VERIFY DATUM LEVEL IS CONSISTENT (1/4" +/-

WITH NO ABRUPT OFFSETS) AT ALL FLOOR LOCATIONS THROUGHOUT PROJECT. IF

FLOOR SURFACE IS NOT CONSISTENT, TAKE APPROPRIATE STEPS TO RECONCILE

FLOOR SURFACE WITH ESTABLISHED DATUM. PROVIDE APPROVED SELF-LEVELING

COMPOUND AT ANY FLOOR SURFACE NOT CONSISTENT WITH ESTABLISHED DATUM

PRIOR TO INSTALLATION OF ANY NEW INTERIOR PARTITIONS. FLOOR DATUM,

LEVELING, FLOOR PREPARATION, INSTALLATION, AND FINAL FLOOR FINISH SHALL BE

ACCEPTABLE TO THE VHA COR.

NOTES - FLOOR PLAN & RCP DEMOLITION

C

D

E

A

B

108 97

MECHANICAL

SHAFT

34 38

B2-49A

PACU 4 -

TOILET

B2-49

PACU 4

B2-47

PACU 4 -

ANTE RM

B2-20A

ANTE RM

B2-16

ICU 1

B2-20

ICU 3

B2-14

NURSE

CONSULT

B2-12

NURSE

SUP.

FLOOR PLAN LEGEND - DEMOLITION

WALL - EXISTING TO REMAIN

WALL - DEMO

OBJECT - DEMO

FLOOR COVERING - DEMO

ACOUSTIC CEILING - DEMO

DOOR - EXISTING TO REMAIN

DOOR - DEMO

KEYNOTES 00

KEY PLAN

N o rt h

I-CA

I-B

I-A

I-C

BLDG 45

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

AD112

SECOND FLOOR - OVERALL FLOOR

PLAN & RCP - DEMOLITION

CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

32'16'8'4'2'0'

North1/8" = 1'-0"

SECOND FLOOR - OVERALL FLOOR PLAN - DEMOLITION

SECOND FLOOR - FLOOR PLAN - DEMOLITION (KEYNOTES 1-20)

1. DEMO SLIDING GLASS DOOR; PATCH & REPAIR FLOOR & WALL AS REQUIRED

2. REMOVE AUTOMATIC DOOR OPENER; STORE FOR REUSE; RE: ELECTRICAL

3. DEMO WALL TILE; ENTIRE ROOM AS OCCURS

4. DEMO FLOOR TILE

5. REMOVE ALL WALL MOUNTED ACCESSORIES; STORE FOR REUSE &

REINSTALLATION

6. REMOVE WALL MOUNTED LIGHT FIXTURE; RE: ELECTRICAL

7. DEMOUNT & REMOVE LAVATORY; STORE FOR REUSE & REINSTALLATION; RE:

PLUMBING

8. DEMOUNT & REMOVE WALL MOUNTED TOILET; STORE FOR REUSE &

REINSTALLATION; RE: PLUMBING

9. REMOVE TOILET GRAB BARS; STORE FOR REUSE & REINSTALLATION

10. DEMO BLINDS, WINDOW COVERINGS

11. REMOVE WALL MOUNTED TVS, MONITORS ETC.; STORE FOR REUSE AND

REINSTALLATION. RE: TECHNOLOGY PLANS

12. REMOVE WALL PAPER AT ALL WALLS TO REMAIN; PATCH, REPAIR & REFINISH

TO RECEIVE NEW PAINT; RE: NEW CONSTRUCTION PLAN, SPECIFICATIONS

13. DEMO (E) DOOR; STORE FOR REUSE

14. DEMO WALL OPENING FOR DOOR; RE: PLAN, DOOR SCHEDULE, DETAILS

15. DEMOUNT & REMOVE WORKSTATION; STORE FOR REUSE & REINSTALLATION

16. REMOVE PATIENT BED HEADWALL; STORE FOR REUSE: RE: ELEC, MECH.

17. REMOVE (E) BEDPAN RINSE SINK; STORE FOR REUSE

18. DEMO WALL; RE: PLANS

19. DEMO FLOOR COVERING; RE: PLAN FOR LOCATION OF NEW PARTITION

WALLS TO DETERMINE EXTENTS OF FLOOR DEMO

20. DEMO VINYL BASE, TYP. ENTIRE ROOM PERIMETER

21. REMOVE AND STORE ALL ROOM SIGNAGE FOR REUSE, TYP.

22. REMOVE NURSE CALL LIGHT (ABOVE DOOR); STORE FOR REUSE; RE:

ELECTRICAL

SECOND FLOOR - REFLECTED CEILING PLAN - DEMOLITION (KEYNOTES 30-42)

30. DEMO CEILING TILE, CEILING GRID

31. DEMO GYP CEILING

32. DEMO LAY-IN LIGHT FIXTURE; TYP. AS OCCURS

33. DEMO RETURN AIR REGISTER; RE: MECHANICAL

34. DEMO DIFFUSER; RE: MECHANICAL

35. REMOVE PRIVACY CURTAIN

36. DEMOUNT & REMOVE OVERHEAD PATIENT LIFT, STORE FOR REUSE; ALT

OPTION - INSTALL NEW PATIENT LIFT; RE: SPECIFICATIONS

37. REMOVE WIFI ACCESS POINT, STORE FOR REUSE; TYP. AS OCCURS

38. DEMO TOILET EXHAUST FAN; RE: MECHANICAL

39. FIRE SPRINKLER HEAD TO REMAIN

40. FIRE SPRINKLER HEAD TO BE RELOCATED; RE: FIRE PROTECTION

41. RADIANT HEAT PANELS TO REMAIN; REMOVE & STORE FOR REINSTALLATION;

RE: ELECTRICAL

42. REMOVE RADIANT HEATERS, STORE FOR REUSE; RE: MECHANICAL

1/8" = 1'-0"

SECOND FLOOR - OVERALL REFLECTED CEILING PLAN - DEMOLITION

E

A

B

108 97654321

(E) PARAPET WALL

PENTHOUSE ROOF

TELEPHONE

CONTROL

CORRIDOR

WAITING

ROOM

STAIRS ELEV 6ELEV 7

SERV

ELEV

SERV

ELEV

MECHANICAL

SHAFT

STAIRS

A. SEE MECHANICAL & ELECTRICAL & PLUMBING DRAWINGS FOR OTHER DEMOLITION

INFORMATION & REQUIREMENTS.

B. REFER TO SHEET GI002 FOR ADDITIONAL INFORMATION

C. CONTRACTOR TO NOTIFY VHA COR FOURTEEN (14) DAYS PRIOR START OF ANY

ROOF WORK TO COORDINATE ANY UTILITY SHUT-OFF, POTENTIAL OPERATIONAL

DISRUPTIONS AND/OR ACCESS TO THE AREAS BELOW THE ROOF.

D. CONTRACTOR SHALL PROVIDE PROTECTION AT THE EXISTING ROOF DRAINS TO

PREVENT DEMOLITION & CONSTRUCTION MATERIALS, DUST AND OR DEBRIS FROM

INFILTRATING STORM DRAIN SYSTEM.

E. NO EXISTING LEAD PAINT IS ANTICIPATED TO BE FOUND IN THE PROJECT AREA.

HOWEVER, IF THE CONTRACTOR DISCOVERS OR UNCOVERS ANY SUSPECTED LEAD

PAINT OR OTHER HAZARDOUS SUBSTANCE, THE VHA COR SHALL BE NOTIFIED.

WORK WITH SUCH SUSPECTED HAZARDOUS MATERIALS SHALL CEASE UNTIL THE

SUSPECTED HAZARDOUS MATERIAL IS TESTED, ABATED IF NECESSARY, AND WORK

AUTHORIZED TO PROCEED BY THE VHA COR.

F. CONTRACTOR TO REMOVE, REFURBISH/ CLEAN, PROTECT AND STORE FIXTURES TO

BE REINSTALLED.

G. DO NOT REMOVE OR OTHERWISE MODIFY ANY EXISTING BUILDING STRUCTURAL

COMPONENTS UNLESS APPROVED BY THE VHA COR.

NOTES - PENTHOUSE & ROOF DEMOLITION

FLOOR PLAN LEGEND - DEMOLITION

WALL - EXISTING TO REMAIN

WALL - DEMO

OBJECT - DEMO

FLOOR COVERING - DEMO

ACOUSTIC CEILING - DEMO

DOOR - EXISTING TO REMAIN

DOOR - DEMO

KEYNOTES 00

KEY PLAN

N o rt h

I-CA

I-B

I-A

I-C

BLDG 45

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

AD113

PENTHOUSE - FLOOR PLAN -

DEMOLITION

CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

32'16'8'4'2'0'

North1/8" = 1'-0"

PENTHOUSE - FLOOR PLAN - DEMOLITION

1. DEMO CONCRETE PAD AT EXHAUST FAN; PATCH & REPAIR FLOOR AS

REQUIRED; CONTRACTOR TO VIF; LOCATION RE: MECHANICAL

2. DEMO MECH CURB; PATCH & REPAIR ROOF AND DECK ASSEMBLY AS

REQUIRED; CONTRACTOR TO VIF; LOCATION RE: MECHANICAL

E

A

B

108 97654321

ROOF

ACCESS

HATCH

SOLAR

PANEL

A. SEE MECHANICAL & ELECTRICAL & PLUMBING DRAWINGS FOR OTHER DEMOLITION

INFORMATION & REQUIREMENTS.

B. REFER TO SHEET GI002 FOR ADDITIONAL INFORMATION

C. CONTRACTOR TO NOTIFY VHA COR FOURTEEN (14) DAYS PRIOR START OF ANY

ROOF WORK TO COORDINATE ANY UTILITY SHUT-OFF, POTENTIAL OPERATIONAL

DISRUPTIONS AND/OR ACCESS TO THE AREAS BELOW THE ROOF.

D. CONTRACTOR SHALL PROVIDE PROTECTION AT THE EXISTING ROOF DRAINS TO

PREVENT DEMOLITION & CONSTRUCTION MATERIALS, DUST AND OR DEBRIS FROM

INFILTRATING STORM DRAIN SYSTEM.

E. NO EXISTING LEAD PAINT IS ANTICIPATED TO BE FOUND IN THE PROJECT AREA.

HOWEVER, IF THE CONTRACTOR DISCOVERS OR UNCOVERS ANY SUSPECTED LEAD

PAINT OR OTHER HAZARDOUS SUBSTANCE, THE VHA COR SHALL BE NOTIFIED.

WORK WITH SUCH SUSPECTED HAZARDOUS MATERIALS SHALL CEASE UNTIL THE

SUSPECTED HAZARDOUS MATERIAL IS TESTED, ABATED IF NECESSARY, AND WORK

AUTHORIZED TO PROCEED BY THE VHA COR.

F. CONTRACTOR TO REMOVE, REFURBISH/ CLEAN, PROTECT AND STORE FIXTURES TO

BE REINSTALLED.

G. DO NOT REMOVE OR OTHERWISE MODIFY ANY EXISTING BUILDING STRUCTURAL

COMPONENTS UNLESS APPROVED BY THE VHA COR.

NOTES - PENTHOUSE & ROOF DEMOLITION

FLOOR PLAN LEGEND - DEMOLITION

WALL - EXISTING TO REMAIN

WALL - DEMO

OBJECT - DEMO

FLOOR COVERING - DEMO

ACOUSTIC CEILING - DEMO

DOOR - EXISTING TO REMAIN

DOOR - DEMO

KEYNOTES 00

KEY PLAN

N o rt h

I-CA

I-B

I-A

I-C

BLDG 45

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

Is o la ti o n R o o m s

A rc h R tk o v a ts

E N

R S

.r v t

/1

/2

:0

:0

P

M

AD130

ROOF PLAN - DEMOLITION CHEYENNE VAMC UPDATE

ISOLATION ROOMS

2360 E. PERSHING AVE, CHEYENNE, WY 82001

442-20-004

I-CA

03/18/2021 GD TK

100% CONSTRUCTION

DOCUMENTS

VEG 20.21

1. DEMO CONCRETE PAD AT EXHAUST FAN; PATCH & REPAIR EPDM (VIF) ROOF

AS REQUIRED; RE: MECHANICAL; RE: SPECIFICATIONS

2. PATCH & REPAIR ABANDONED EPDM (VIF) ROOF PENETRATION; RE:

MECHANICAL; RE: SPECIFICATIONS

32'16'8'4'2'0'

North1/8" = 1'-0"

ROOF PLAN - DEMOLITION

E

A

B

108 97

STAIR

ELEC

VAULTICU 4ICU 5ICU 6PACU 3

NURSING

STATION

N MEDS

SUPPLY

SUPPLY

STOR

EQUIP

STOR

OFFICETOILET

OFFICE

EQUP

STOR

HAC

F TLTM TLT

OFFICE

NURSING

LOUNGE

NURSING

LOCKER

RM

SOILED

UTIL

HAC

IV RM

NURSING

BTH/

SHOWER

SURGERY

WAITING

RM

TOILET

NURSE

TLT

CLEAN

UTIL

CORRIDOR

PACU 2

NURSE

STATION CORRIDOR

OFFICE

CORRIDOR

PACU 1

ANTE RM

MEDS

NURSING

W. SUPP

A411

F7

A410

F7

A412

F7

CORRIDOR B2-20A

ANTE RM

B2-16

ICU 1

B2-20

ICU 3

MECHANICAL

SHAFT

B2-49A

PACU 4 -

TOILET

B2-49

PACU 4

B2-47

PACU 4 -

ANTE RM

184 SF

B2-118

ICU 2

B2-16A

ANTE RM

B2-14

NURSE

CONSULT

B2-12

NURSE

SUP.

NOTE: ELECTRICAL PANEL LOCATIONS;

RE: ELECTRICAL SHEET E111 FOR MORE INFORMATION

A. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR MORE

INFORMATION.

B. REFER TO SHEET GI-002 FOR ADDITIONAL INFORMATION

C. REFER TO ENLARGED FLOOR PLANS FOR ADDITIONAL INFORMATION AND

DIMENSIONS.

D. ALL WALLS WILL BE FINISHED WITH 5/8" GYP. BD. TO A LEVEL 4 FINISH AND PAINTED, UNO.

E. REFER TO DOOR SCHEDULE FOR MORE INFORMATION.

F. ALIGN NEW WALLS WITH ADJACENT EXISTING WALLS WHERE NEW WALL EXTENDS IN

THE SAME DIRECTION.

G. ALIGN CENTER OF DEMISING WALLS OR FINISH FACE OF CHASE WALLS WITH CENTER

OF WINDOW MULLION, UNO.

H. ALL INTERIOR PARTITIONS TO BE TYPE A3, UNO.

I. SOME EXISTING WALLS MAY BE LATHE & PLASTER CONSTRUCTION AND NOT GYPSUM

WALL BOARD. CONTRACTOR TO VIF WALL ASSEMBLIES WITHIN SCOPE OF WORK.

NOTES - NEW CONSTRUCTION

C

D

E

A

B

108 97

A410

F5

A411

F5

A412

F5

MECHANICAL

SHAFT

B2-20A

ANTE RM

B2-16

ICU 1

B2-20

ICU 3

B2-49A

PACU 4 -

TOILET

B2-49

PACU 4

B2-47

PACU 4 -

ANTE RM

B2-16A

ANTE RM

B2-14

NURSE

CONSULT

B2-12

NURSE

SUP.

FLOOR PLAN LEGEND - NEW CONSTRUCTION

WALL - EXISTING

WALL - NEW CONSTRUCTION

FLOOR COVERING - NEW CONSTRUCTION

ACOUSTIC CEILING - NEW CONSTRUCTION

PATCH AND REPAIR FLOOR/ ROOF

DOOR - EXISTING

DOOR - NEW CONSTRUCTION

KEY PLAN

N o rt h

I-CA

I-B

I-A

I-C

BLDG 45

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

C U s e rs

\V A rc h it e c t

\D o c u m e n ts

\4

-2

-0

I…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .