Ultrasonic Thickness Measurements 2011.pdf
PDF 299 KB Posted
- Solicitation number
- ADF&G ITB # 2027-1100-0088 - RV Medeia Shipyard Services FY27
- Issued by
- Alaska
About this file
This is an Ultrasonic Thickness Measurement Report (TM-6) prepared by Elander Inspection Ltd., a nondestructive testing and marine inspection firm based in Richmond, British Columbia, Canada. The report documents thickness measurements of miscellaneous structural members and various piping systems aboard the R.V. Medeia, conducted on March 17, 2011, under Report No. E11-018-004. The inspection measured metal thickness across multiple vessel systems including suction and discharge manifolds, overboard penetrations, sewage piping, bilge pump piping, waste water piping, air receivers, and fuel tank piping. The measurements were taken at numerous locations throughout the vessel and compared against original thickness specifications and class minimum thickness requirements to identify corrosion and material diminution.
The report presents detailed gauged thickness measurements in inches for each structural element and piping section tested, with calculations showing the diminution in thickness and corresponding percentage loss relative to original or scheduled specifications. A general note indicates that all original thicknesses used in the report require confirmation by original ship's drawings, and diminution calculations were not possible for data lacking original thickness information. The report identifies several areas where measured thicknesses fall below class minimum standards, indicated by the "Below class min" notation in the data tables. As a technical inspection document, this report serves to establish the current structural condition of the R.V. Medeia's systems and inform decisions regarding maintenance, repairs, or compliance with maritime classification standards.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THICKNESS MEASUREMENT REPORT - TM-6
REPORT ON THICKNESS MEASUREMENT OF MISCELLANEOUS STRUCTURAL MEMBERS
Substantial corr
Ship's Name: Id.No: Legend: Below class min
Port Stbd
Inches Sch. Inches Inches Inches Inches Inches % Inches %
S1 Top Box 0.375 0.263 0.350 0.341 0.03 6.7% 0.03 9.1% GENERAL NOTE: ALL ORIGINAL
Aft Box 0.375 0.263 0.366 0.345 0.01 2.4% 0.03 8.0% THICKNESSES USED IN THIS
Btm Box 0.375 0.263 0.369 0.327 0.01 1.7% 0.05 12.8% REPORT ARE TO BE CONFIRMED
- - BY ORIGINAL SHIPS' DWGS
S2 Top Box 0.375 0.263 0.381 - 0.00 0.0%
Aft Box 0.375 0.263 0.333 - 0.04 11.2% DO NOT USE THE REFERENCED
Btm Box 0.375 0.263 0.359 - 0.02 4.3% THICKNESES WITHOUT FIRST
- - CONFIRMING THE ACUTAL
- - THICKNESS.
O1 Top Box 0.375 0.263 0.316 0.373 0.06 15.7% 0.00 0.5%
Aft Box 0.375 0.263 0.338 0.334 0.04 9.9% 0.04 10.9% DIMINUTION CALCULATIONS
Btm Box 0.375 0.263 0.342 0.341 0.03 8.8% 0.03 9.1% WAS NOT POSSIBLE FOR DATA
- - WITH NO ORIGINAL THICKNESS
O2 Top Box 0.375 0.263 0.383 - 0.00 0.0%
Aft Box 0.375 0.263 0.338 - 0.04 9.9%
Btm Box 0.375 0.263 0.345 - 0.03 8.0%
P1 0.000 0.250 - -
P2 0.000 0.242 - -
P3 0.000 0.278 - -
P4 0.000 0.238 - -
P5 0.000 0.128 - -
P6 0.000 0.248 -
P7 0.000 0.238 -
P8 0.000 0.245 -
Suction Manifold Pipe
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Discharge Manifold
Top Plate, Aft Plate
Btm Plate
Drawing/CommentsPort Starboard
Suction Manifold
Top Plate, Pipe Size Pipe Sch.
Location of Structure: Void/Engine Room/Fuel Tanks Frame No. n/a
Description Element /
Frame No.
Draw ref.
Orig thk.
Class min thk.
Gauged
R.v. Medeia N/A Report No: E11-018-004
Description: Various Piping Systems
Diminution
Top Plate, Aft Plate
Btm Plate
Aft Plate
Btm Plate
Top Plate, Aft Plate
Btm Plate
ELANDER INSPECTION LTD.
Suite 128 – 11800 River Road, Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
R.V. Medeia - UTM Piping ELANDER INSPECTION LTD. March 17, 2011
Ship's Name: Id.No: Legend: Below class minR.v. Medeia N/A Report No: E11-018-004
Description: Various Piping Systems
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
D1 0.000 0.240 - -
D2 0.000 0.246 - -
D3 0.000 0.241 - -
D4 0.000 0.255 - -
D5 0.000 0.178 - -
D6 0.000 0.242 - -
D7 0.000 0.258 - -
D8 0.000 0.234 - -
0.000
Top 1 0.000 0.177 - -
Btm 1 0.000 0.182 - -
Top 2 0.000 0.177 - -
Btm 2 0.000 0.182 - -
Top 3 0.000 0.179 - -
Btm 3 0.000 0.196 - -
Top 0.500 0.337 0.236 0.490 0.00 0.0% - Original thickness estimated
Top 0.500 0.337 0.236 0.496 0.00 0.0% - Original thickness estimated
Side 0.500 0.337 0.236 0.460 - 0.00 0.0% Original thickness estimated
Side 0.500 0.337 0.236 0.465 - 0.00 0.0% Original thickness estimated
Side 0.500 0.337 0.236 0.467 - 0.00 0.0% Original thickness estimated
Top 0.000 0.260 - -
Btm 0.000 0.265 - -
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
(Area tested from E/R Aft - 10' )
Fwd Nozzle
Sea Chest
Main Body and frm Fwd BHD + 10' Approx)
40' of Pipe from Manifold
Discharge Manifold Pipe
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
Inbd B1 0.337 0.236 0.260 0.08 22.8%
Aft B1 0.337 0.236 0.272 0.07 19.3%
Top B2 0.337 0.236 0.286 0.05 15.1% -
Btm B2 0.337 0.236 0.262 0.08 22.3% -
Top B3 0.337 0.236 0.289 0.05 14.2% -
Top B3 0.337 0.236 0.268 0.07 20.5% -
Fwd B4 0.337 0.236 0.268 0.07 20.5% -
Side B4 0.337 0.236 0.258 0.08 23.4% -
0.000 0.199 - -
0.000 0.201 - -
0.000 0.184 - -
0.000 0.180 - -
0.000 0.167 - -
0.000 0.162 - -
Top 0.000 0.284 - -
Aft Side 0.000 0.277 - -
0.000 - -
OB-1 4 Sch. 80 0.337 0.236 0.279 - 0.06 17.2%
4 Sch. 80 0.337 0.236 0.244 - 0.09 27.6% ds - -
OB-2 4 Sch. 80 0.337 0.236 0.262 0.08 22.3%
4 Sch. 80 0.337 0.236 0.268 0.07 20.5%
4 Sch. 80 0.337 0.236 0.282 0.06 16.3%
OB-3 4 Sch. 80 0.337 0.236 0.175 - 0.16 48.1%
4 Sch. 80 0.337 0.236 0.179 - 0.16 46.9%
4 Sch. 80 0.337 0.236 0.148 - 0.19 56.1%
OB-4 4 Sch. 80 0.337 0.236 0.285 - 0.05 15.4%
4 Sch. 80 0.337 0.236 0.249 - 0.09 26.1%
Vertical Pipe below Elbow going to Tank
Horizontal pipe after Fwd BHD
Discharge Pipe
Hortizontal Pipe going fwd
Aft of Fwd BHD
90 degree Elbow aft of Valve
Pipe System in Area of Overboard
Void Space Overboard Penetrations
1st Fwd (Fwd BHD)
1st Fwd
2nd Fwd
2nd Fwd
3rd Fwd
3rd Fwd (Aft. BHD)
Sewage Pipe Through-hull
Fwd Nozzle
Bildge Pump and Piping
90 Degree Elbow
Vertical Pipe below Elbow
Vertical pipe above pump
Vertical pipe above pump
Fwd Nozzle
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
1 Top 4 Sch. 80 0.337 0.236 0.174 0.16 48.4% -
Side 4 Sch. 80 0.337 0.236 0.212 0.13 37.1% -
Btm 4 Sch. 80 0.337 0.236 0.206 0.13 38.9% -
Outbd Radius - -
2 Top 4 Sch. 80 0.337 0.236 0.340 0.00 0.0% -
Btm 4 Sch. 80 0.337 0.236 0.349 0.00 0.0% -
3 Top 4 Sch. 80 0.337 0.236 0.297 0.04 11.9% -
Btm 4 Sch. 80 0.337 0.236 0.271 0.07 19.6% -
SD-1 Top 4 Sch. 80 0.337 0.236 0.258 - 0.08 23.4%
Inbd 4 Sch. 80 0.337 0.236 0.274 - 0.06 18.7%
Btm 4 Sch. 80 0.337 0.236 0.274 - 0.06 18.7%
Outbd 4 Sch. 80 0.337 0.236 0.265 - 0.07 21.4%
SD-2 Top 4 Sch. 80 0.337 0.236 0.212 - 0.13 37.1%
Inbd 4 Sch. 80 0.337 0.236 0.197 - 0.14 41.5%
Btm 4 Sch. 80 0.337 0.236 0.202 - 0.14 40.1%
Outbd 4 Sch. 80 0.337 0.236 0.202 - 0.14 40.1%
SD-3 Top 4 Sch. 80 0.337 0.236 0.265 - 0.07 21.4%
Inbd 4 Sch. 80 0.337 0.236 0.264 - 0.07 21.7%
Btm 4 Sch. 80 0.337 0.236 0.274 - 0.06 18.7%
Outbd 4 Sch. 80 0.337 0.236 0.264 - 0.07 21.7%
SD-4 Top 4 Sch. 80 0.337 0.236 0.285 - 0.05 15.4%
Inbd 4 Sch. 80 0.337 0.236 0.275 - 0.06 18.4%
Btm 4 Sch. 80 0.337 0.236 0.268 - 0.07 20.5%
Outbd 4 Sch. 80 0.337 0.236 - -
Horizontal Pipe going Aft
Horizontal pipe going Inbd.
Horizontal Pipe past Loc. 3
90 Degree Elbow
90 degree Elbow Fwd of reducer
Sewage discharge Pipe in Closet
Horizontall Pipe
Waste Water to Tank located in Fwd Berth Area (Port side)
Pipe aft of reducer
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
SD-5 Top 4 Sch. 80 0.337 0.236 0.265 - 0.07 21.4%
Inbd 4 Sch. 80 0.337 0.236 0.240 - 0.10 28.8%
Btm Sch. 80 0.337 0.236 0.247 - 0.09 26.7%
Outbd Sch. 80 0.337 0.236 0.240 - 0.10 28.8%
SD-6 Fwd Sch. 80 0.337 0.236 0.275 - 0.06 18.4%
Aft Sch. 80 0.337 0.236 0.280 - 0.06 16.9%
Top 4" Sch 40 0.237 0.166 0.242 0.00 0.0% - Pipes identified Fwd to Aft
Btm 4" Sch 40 0.237 0.166 0.267 0.00 0.0% -
Top 4" Sch 40 0.237 0.166 0.210 0.03 11.4% -
Btm Sch 40 0.204 0.143 0.209 0.00 0.0% -
Top 1 1/4" Sch 80 0.190 0.133 0.197 0.00 0.0% -
Btm 1 1/4" Sch 80 0.190 0.133 0.172 0.02 9.5% -
Top 0.237 0.166 0.275 0.00 0.0% -
Btm 0.237 0.166 0.255 0.00 0.0% -
Top 0.187 0.131 0.172 0.171 0.02 8.0% 0.02 8.6%
Middle 0.187 0.131 0.177 0.191 0.01 5.3% 0.00 0.0%
Middle 0.187 0.131 0.181 0.180 0.01 3.2% 0.01 3.7%
Btm 0.187 0.131 0.180 0.169 0.01 3.7% 0.02 9.6%
Top 0.187 0.131 ds 0.214 - 0.00 0.0%
Aft Side 0.187 0.131 0.200 0.195 0.00 0.0% 0.00 0.0%
Btm 0.187 0.131 0.164 0.176 0.02 12.3% 0.01 5.9%
Top 0.187 0.131 0.190 0.00 0.0% -
Aft Side 0.187 0.131 0.172 0.02 8.0% -
Btm 0.187 0.131 0.168 0.02 10.2% -
Top 0.187 0.131 0.164 0.172 0.02 12.3% 0.02 8.0%
Middle 0.187 0.131 0.170 0.165 0.02 9.1% 0.02 11.8%
Middle 0.187 0.131 0.168 0.165 0.02 10.2% 0.02 11.8%
Btm 0.187 0.131 0.176 0.164 0.01 5.9% 0.02 12.3%
Outboard Head
Outboard Head
Shell Circ 1
Shell Circ 1
Shell Circ 1
Air Receivers
Shell Circ 2
Shell Circ 2
Shell Circ 2
Inboard Head
Inboard Head
Inboard Head
Inboard Head
Outboard Head
Outboard Head
2nd Fwd
3rd Fwd
3rd Fwd
4th Fwd
4th Fwd
Engine Room Overboad Discharge Pipe
1st Fwd
1st Fwd
2nd Fwd
Vertical Pipe below Elbow
Upper hoizontal Pipe
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Top 2" Sch. 80 0.218 0.153 0.196 0.02 10.1% -
Outbd 0.218 0.153 0.177 0.04 18.8% -
Btm 0.218 0.153 0.196 0.02 10.1% -
Inbod 0.218 0.153 0.195 0.02 10.6% -
Top 2" Sch. 80 0.218 0.153 0.209 0.01 4.1% -
Outbd 0.218 0.153 0.201 0.02 7.8% -
Btm 0.218 0.153 0.197 0.02 9.6% -
Inbod 0.218 0.153 0.213 0.01 2.3% -
Top 2" Sch. 80 0.218 0.153 0.190 0.03 12.8% -
Outbd 0.218 0.153 0.191 0.03 12.4% -
Btm 0.218 0.153 0.193 0.03 11.5% -
Inbod 0.218 0.153 0.198 0.02 9.2% -
Top 2" Sch. 80 0.218 0.153 0.223 0.00 0.0% -
Outbd 0.218 0.153 0.212 0.01 2.9% -
Btm 0.218 0.153 0.217 0.00 0.5% -
Inbod 0.218 0.153 0.216 0.00 0.9% -
Top 2" Sch. 80 0.218 0.153 0.201 0.02 7.8% -
Outbd 0.218 0.153 0.211 0.01 3.2% -
Btm 0.218 0.153 0.219 0.00 0.0% -
Inbod 0.218 0.153 0.218 0.00 0.0% -
Top 2" Sch. 80 0.218 0.153 0.200 0.02 8.3% -
Outbd 0.218 0.153 0.201 0.02 7.8% -
Btm 0.218 0.153 0.206 0.01 5.5% -
Inbod 0.218 0.153 0.196 0.02 10.1% -
Top 2" Sch. 80 0.218 0.153 0.216 0.00 0.9% -
Outbd 0.218 0.153 0.192 0.03 11.9% -
Btm 0.218 0.153 0.214 0.00 1.8% -
Inbod 0.218 0.153 0.198 0.02 9.2% -
Bunker Fuel Tank - Fwd Space
Middle Fuel Tank - Aft Space Fwd
Middle Fuel Tank - Aft Space Aft
Middle Fuel Tank - Fwd Space fr. Fwd BHD
Bow Fuel Tank - Aft Space
Bow Fuel Tank - Middle Space
Fuel Tank Piping from Manifold
Bow Fuel Tank - Fwd Space
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
Top 2" Sch. 80 0.218 0.153 0.208 0.01 4.6% -
Outbd 0.218 0.153 0.198 0.02 9.2% -
Btm 0.218 0.153 0.196 0.02 10.1% -
Inbod 0.218 0.153 0.196 0.02 10.1% -
0.218 0.153 0.196 0.02 10.1% -
Top 2" Sch. 80 0.218 0.153 0.198 0.02 9.2% -
Outbd 0.218 0.153 0.205 0.01 6.0% -
Btm 0.218 0.153 0.205 0.01 6.0% -
Inbod 0.218 0.153 0.198 0.02 9.2% -
Bunker Fuel Tank - Aft Space
1. Bunker Fuel Tank - 2nd Space fr. Fwd Bhd.
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
File details come from the government source that posted it. Updated .