Accuren Ultrasonic Testing Report 2020.pdf
PDF 2 MB Posted
- Solicitation number
- ADF&G ITB # 2027-1100-0088 - RV Medeia Shipyard Services FY27
- Issued by
- Alaska
About this file
This is a Nondestructive Examination Report detailing ultrasonic thickness testing services performed by Acuren for Point Hope Maritime on the vessel M.V. Medeia in Victoria, British Columbia on March 4, 2020. The scope of work involved conducting ultrasonic thickness gauging on structural components of the vessel in locations as directed by the owner's representative. The inspection examined multiple areas including wind water plates, keel plates, forepeak bulkhead, three transverse sections, shell plates and stern tubes, engine room bilge, areas adjacent to the sea chest and keel coolers, waterline fire pump and cofferdam hull plates, and areas in way of ballast tank structures. The work was performed using an Olympus Epoch 600 ultrasonic testing instrument with calibration due May 26, 2020, following Acuren's PAC-UT-14T001 procedure (Revision 06/2019) and acceptance standards specified by the client. Technicians Randy Wallin and Teri Hope conducted the testing on carbon steel structural components with coated surfaces at temperatures between 12°C and 15°C.
The report identified localized pitting on the starboard side shell plate at frame 42 and frame 15, as well as under the starboard side stern tubes, with assumed thickness measurements used for diminution calculations based on areas in good condition due to unavailability of original thickness data and ship drawings. The client was required to inspect the deliverable and provide written rejection within 15 business days of receipt or the report would be deemed accepted. Services were governed by Acuren's Master Services Agreement and Standard Service Terms. The report was generated in accordance with form CAN-QUA-02F007 R06 dated May 7, 2018, with Acuren's Richmond, British Columbia office identified as the service provider.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A20-60POI001-6145373-200304-RLW-01.docx
NONDESTRUCTIVE EXAMINATION
CLIENT: POINT HOPE MARITIME
345 Harbour Road Victoria B.C V9A 3S2
PAGE: 1 of 8
DATE: March 4, 2020
ACUREN JOB #: 6145373
REPORT #: 6145373-200304-RLW-01
CONTRACT/PO: WO: N/A
ATTENTION: SAM JOHNSON WORK LOCATION: Victoria BC
PROJECT: M.V. Medeia
ITEM(S) EXAMINED: Structural Components
PART #: N/A MATERIAL: Carbon steel THICKNESS: N/A
SCOPE: Carry out ultrasonic thickness gauging on board the vessel “M.V. Medeia” in locations as directed by the owner’s representative.
TYPE OF INSPECTION: Ultrasonic
TEST DETAILS:
ACCEPTANCE STANDARD: Client's Information REVISION: N/A
PROCEDURE/TECHNIQUE: PAC- UT- 14T001 REVISION: 06 / 2019
TYPE: Thickness Echo to Echo METHOD: Contact
INSTRUMENT: Olympus MODEL: Epoch 600 S/N: 100048111 CAL DUE: May 26, 2020
CAL. BLOCK: Step Block S/N: 07-6664 CABLE-TYPE: Coaxial LENGTH: 5'
CAL. BLOCK: N/A S/N: N/A COUPLANT: Echo Ultrasonics - EchoMix
Probe & Technique Details:
TEST
ANGLE
PROBE
TYPE
CRYSTAL
SIZE
FREQ.
(MHZ)
SERIAL
NUMBER
DAMPING
Ω
TEST
FROM
REFERENCE
REFLECTOR
TRANSFER
VALUE
REFERENCE
SCAN
dB RANGE dB % FSH
1 0 dual .250” 5 02F142 50 One face BWE n/a 54 60 +6 1.0”
TEST SURFACE CONDITION: Coated TEST SURFACE TEMPERATURE: 12°C to 15°C
RESULTS:
Ultrasonic thickness measurements were performed in the following areas:
Wind Water Plates
Keel Plates
Forepeak bulkhead
Three (3) transverse sections
Shell plates und the stern tubes
Engine room bilge
Client acknowledges receipt and custody of the report or other work ("Deliverable"). Client agrees that it is responsible for assuring that acceptance standards, specifications and criteria in the Deliverable and Statement of Work ("SOW") are correct. Client acknowledges that Acuren is providing the Deliverable according to the SOW, and not any other standards. Client acknowledges that it is responsible for the failure of any items inspected to meet standards, and for remediation. Client has 15 business days following the date Acuren provides the Deliverable to inspect it, identify deficiencies in writing, and provide written rejection, or else the Deliverable will be deemed accepted. The Deliverable and other services provided by Acuren are governed by a Master Services Agreement ("MSA"). If the parties have not entered into an MSA, then the Deliverable and services are governed by the SOW and the "Acuren Standard Service Terms" (www.acuren.com/serviceterms) in effect when the services were ordered.
CLIENT: TOTAL HOURS S.T. O.T. SHIFT
CLIENT PRINTED NAME CLIENT SIGNATURE
ACCEPTED & ACKNOWLEDGED BY
ST
TECHNICIAN: See Project -- Day
ACUREN
ND
TECHNICIAN: Timesheet -- -- PM
TECHNICIAN: Randy Wallin Teri Hope KILOMETRES: OTHER CHARGES: YES NO st Technician nd
Technician
(IF YES, SEE DAILY OR PROJECT TIME REPORT)
REVIEWER: (Generated Using: CAN-QUA-02F007 R06 - 05/07/2018)
12271 Horseshoe Way Richmond, BC, Canada V7A 4V4 www.acuren.com
Phone: 604.275.3800 Fax: 604.274.7235 http://www.acuren.com/serviceterms
POINT HOPE MARITIME
M.V. Medeia Page 2 of 8
ACUREN JOB # 6145373
REPORT # 6145373-200304-RLW-01
Areas adjacent to the sea chest, keel coolers and keel cooler penetrations
Waterline fire pump and cofferdam hull plates
Areas in way of the ballast tank structures
Original thickness and original ship drawings were not available prior to inspection. Assumed thickness measurements were used for diminution calculation based on measurements from areas in good condition.
Localized pitting was noted on the starboard side shell plate at frame 42 and frame 15 as well as under the starboard side stern tubes.
See the following details.
M.V. Medeia Page 3 of 8
M.V. Medeia Page 4 of 8
M.V. Medeia Page 5 of 8
M.V. Medeia Page 6 of 8
M.V. Medeia Page 7 of 8
M.V. Medeia Page 8 of 8
File details come from the government source that posted it. Updated .