Ultrasonic Testing Trouble Spots 2023.docx

DOCX document 13 KB Posted

Attached to
ADF&G ITB # 2027-1100-0088 - RV Medeia Shipyard Services FY27
Solicitation number
ADF&G ITB # 2027-1100-0088 - RV Medeia Shipyard Services FY27
Issued by
Alaska

About this file

This document is a list of ultrasonic testing trouble spots requiring inspection, likely for a marine vessel maintenance or inspection contract. The document identifies specific locations within the engine room and on the outside hull that have been flagged for ultrasonic testing due to concerns about structural integrity, corrosion, or wear. Engine room trouble spots include six areas located between specific frame numbers, primarily on the port side, with several locations near the oil tank and center frame. Outside hull trouble spots include five areas marked with white chalk, encompassing stern zincs on both port and starboard sides, corroded zinc tabs, gouging on the port keel cooler, and a weld line on the port stabilizer.

No pricing terms, contract duration, response dates, bidder meeting information, set-asides, or other contractual details are provided in this document. This appears to be a technical reference document or inspection checklist rather than a formal solicitation notice or contract specification.

View the file

Other files

File Type Posted
Drawing 8-1 Medeia Keel Cooler Arrangements Drawing.pdf PDF
Drawing 17 -1 Medeia Bilge & Ballast Piping.pdf PDF
Drawing 4 -2 Medeia Zinc Location & Types -starboard.jpg JPG image
RV_Medeia_Paint_Specification.docx DOCX document
Drawing 12-3 Crane Specs.pdf PDF
Drawing 17-2 Hold Plan.PDF PDF
Elander 2006-4.jpg JPG image
Elander2014-6.jpg JPG image
Ultrasonic Testing Findings 2023.docx DOCX document
Ultrasonic Report 2011.pdf PDF
Drawing 12-2 Crane Diagram.pdf PDF
Elander2006 UltraSonic Test.jpg JPG image
Drawing 13-1 General Arrangement for Clad Welding.PDF PDF
Drawing 12-1 Medeia Crane Load Chart.pdf PDF
Medeia Megger Report 2023.pdf PDF
Drawing 2-1 Medeia Outboard Profile.pdf PDF
Elander2014-3.jpg JPG image
Elander2014-2.jpg JPG image
Elander2014-8.jpg JPG image
Ultrasonic Thickness Measurements 2011.pdf PDF
Elander 2006-5.jpg JPG image
Elander2014-7.jpg JPG image
Drawing 9-2 Trans. Frs & Long'L Section.PDF PDF
Elander2006-8.jpg JPG image
Elander KeelCoolers 2006.jpg JPG image
Drawing 3 -1 Medeia Bilge & Ballast Piping.pdf PDF
Drawing 16-2 Medeia Wiring Schematic.pdf PDF
Elander2006-7.jpg JPG image
Elander2014-4.jpg JPG image
Elander 2006-2.jpg JPG image
Elander 2006 Shell Expansion.jpg JPG image
ADFG ITB 2027-1100-0088 - FY27 RV Medeia Shipyard Services.pdf PDF
MSD INSTRUCTION MANUAL.doc DOC document
Drawing 16-5 Medeia 42 Circuit Panel 5.pdf PDF
Elander2014 Ultrasonic Test.jpg JPG image
Drawing 5-2 Medeia Rudder Fabrication -Allied.PDF PDF
Drawing 5-1 Medeia Rudder Fabrication -Allied.PDF PDF
10-1 TW-200LP Steel 4 View Drawing.pdf PDF
Elander 2006-3.jpg JPG image
Drawing 9-1 General Scanting.PDF PDF
Accuren Ultrasonic Testing Report 2020.pdf PDF
Drawing 16-1 Medeia Electrical pilot house panel.PDF PDF
Drawing 4 -1 Medeia Zinc Location & Types -port.jpg JPG image
Elander2006-6.jpg JPG image
Drawing 1-1 Medeia Docking Plan.pdf PDF
Drawing 1-2 Medeia Electrical Service -Shore Tie.jpg JPG image
Drawing 16-3 Medeia 42 Circuit Panels 1 & 2.pdf PDF
Elander2014-5.jpg JPG image
Drawing 16-4 Medeia 42 Circuit Panels 3 & 4.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ultrasonic Testing Trouble Spots

· Engine room:

1. Between 35 and 36 Port side

2. Between 36 and 37 Port side

3. Between 34 and 35 under plugger

4. Between 36 and 37 just port of oil tank (center frame)

5. “ “ “ starboard of center frame

6. Between 35 and 36 just port of oil tank (center frame)

· Outside hull: (circled in white chalk)

1.Stern zincs by rudders (P&S)

2. Stern zincs just fore of rudder zincs (P&S)

3. Any zincs with corrosion around the tabs

4. Gouging on port keel cooler aft 2 coolers in from outboard

5. Port stabilizer just fore on weld line