This document is a solicitation for a facilities maintenance services contract. The VA Greater Los Angeles Healthcare System is seeking a contractor to provide preventative maintenance, inspections, and repairs for the North Campus HVAC-R systems at their facility located in Los Angeles, California. Services will be for an initial base year with four optional one-year extensions. The contractor must have licenses for HVAC, plumbing, and refrigeration work in California and meet additional responsibility requirements. The contract will be set aside for veteran-owned small businesses. Offers are due by July 15, 2020 and pricing will be fixed for the contract period. Award will be made to the lowest priced responsive and responsible offeror meeting all requirements if their price is within available funding.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRI-DIM FILTER CORPORATION
TRI -PURE� HEPA &
HEPAMAX� F ILTERS
WHEN CLEAN AIR IS CRITICAL
GASKET SEAL
SEPARATOR
STYLE
HEPA
FILTERS� �
GASKET SEAL
SEPARATOR STYLE
HEPA FILTERS
FEATURES:
��Available in
Standard and High Flow Models
��Variety of Frame
Materials – Both Wood and Metal
��Microfiber Media
Packs
��Rolled and
Tapered Aluminum Separators
��Efficiencies available from 99.97% @ 0.3 �m to 99.99% @
0.3 �m
��Scan Testing
Available
��Gasket Seal
��Faceguards optional on either of both faces
��Quality-
Controlled Manufacturing Facility
Tri-Dim Filter Corporation’s TRI-PURE� HEPA & HEPAMAX™ filters offer a complete line of high efficiency filters for your critical applications and environments. Tri- Dim’s quality-controlled manufacturing facility ensures that you receive the highest quality product.
Both TRI-PURE™ HEPA and HEPAMAX™ are available in a variety of styles to meet your demanding application needs. TRI-PURE™ HEPA is our standard capacity HEPA rated at 250 FPM with an initial resistance 1.0” W.G. The TRI-PURE HEPAMAX™ is our high flow model with 80% more media than our standard version and is rated at 500 FPM with an initial resistance 1.4” W.G.
The TRI-PURE™ HEPA Gasket Seal product line is offered in a variety of frame materials; some of the options include particleboard, plywood, galvanized steel and stainless steel. TRI-PURE™ metal frames use the Z-Body style that allows for maximum strength and maximum media surface area.
TRI-PURE™ HEPA and HEPAMAX™ media packs are constructed utilizing moisture resistant, glass microfibers.
The TRI-PURE™ media pack is supported by aluminum separators that are rolled and tapered and placed between each pleat to maximize performance, ensure maximum airflow at minimum resistance and to protect the media pack.
TRI-PURE™ HEPA and HEPAMAX™ filters have a minimum efficiency at rated airflow of 99.97% on 0.3 micron size particles.
TRI-PURE� HEPA &
HEPAMAX�
TRI-PURE™ HEPA and HEPAMAX™ filters are available with optional faceguards to protect the filter media from damage. Faceguards are available on either one or both faces of the filter and the standard faceguard construction is expanded aluminized steel. Other materials are available.
Tri-Dim is a full line filter manufacturer able to provide the full range of HVAC and Cleanroom filtration products and services to you and your company. Tri-Dim also provides local service through a network of dedicated, factory-trained sales professionals that can work with you on your filtration needs. Contact your local sales professional at 1-800-458-9835.
for a free, no obligation filter and IAQ assessment.
filters are auto-scan tested to ensure there are no leaks greater than .01% of the upstream challenge in the media pack and in the media to pack seal. Tri-Dim offers higher efficiency models - please contact us for details.
TRI-PURE™ HEPA and HEPAMAX™ filters are available in either a gasket seal or
Scan Tested TRI-PURE™ HEPA and HEPAMAX™ filters have a minimum efficiency of 99.99% on
0.3 micron size particles. These filters are scan tested to ensure there are no pinhole leaks greater than 0.01% in the media pack and the media to frame seal utilizing Tri-Dim's Inert Optical Scan Testing or Tri-Dim's Auto Scan (at factory discretion). Tri- Dim offers higher efficiency models - please contact us for details.
gel seal configuration. The standard gasket is 0.75 inch wide x 0.25 inch thick neoprene and is available on either upstream, downstream or on both faces of the filter. Other gasket options are available. For TRI-PURE™ HEPA and HEPAMAX™ filters that are available in a Gel Seal configuration, consult the TRI-PURE™ HEPA and HEPAMAX™ Gel Seal literature (#1700-4) or contact your local sales professional.
GASKET SEAL
SEPARATOR STYLE
HEPA FILTERS
TRI-PURE� HEPA &
HEPAMAX�
Tri-Dim’s TRI-PURE� HEPA media pack
TRI-PURE� Gasket Seal
Tri-Dim’s HEPA Auto Scan Testing Apparatus
TRI-PURE� HEPA DRAWING
Local Representation:
TRI-DIM FILTER CORPORATION
P.O. BOX 466 � 93 INDUSTRIAL DRIVE
LOUISA, VA 23093
(540) 967-2600 � FAX: (540) 967-2835
EMAIL: info@tridim.com � Website: www.tridim.com T O L L F R E E 1 - 8 0 0 - 4 5 8 - 9 8 3 5
Brochure # 1700-1
Revision: 08/07
Tri-Dim Filter Corporation is committed to continual product development – all descriptions, specifications and performance data are subject to change without notice.
Tri-Dim® and Tri-Dek® are Registered Trademarks of Tri-Dim Filter Corporation. Tri-Pure™ and HEPAMAX™ are Trademarks of Tri-Dim Filter Corporation.
TRI-PURE™ HEPA
TYPICAL APPLICATIONS
� HEALTHCARE
� BIOTECH
� PHARMACEUTICAL
� FOOD PROCESSING
� SEMICONDUCTOR
� BIOMEDICAL
� UNIVERSITIES
� LABORATORIES
� INDUSTRIAL APPLICATIONS
� PHOTO PROCESSING
� MUSHROOM GROWERS
� RESEARCH
TRI-PURE� HEPA
STANDARD CAPACITY MODEL
Recommended Airflow = 250 FPM (1.25 m/sec)
Resistance 12” Deep @ 250 FPM = 1.0” W.G. (250 Pascals) 6” Deep @ 125 FPM = 1.0” W.G. (250 Pascals)
Temperature Limit = 250°F (121°C)
Frame Construction = Galvanized, Stainless Steel, Particleboard, Fire Retardant Particleboard, Plywood and others.
Sealant = Polyurethane
Media = Glass Microfiber
Separators = Aluminum
UL 900 Class 1*
* Metal Frame Version
TRI-PURE HEPAMAX�
HIGH FLOW MODEL
Recommended Airflow = 500 FPM (2.5 m/sec)
Resistance 12” Deep @ 500 FPM = 1.4” W.G. (350 Pascals) 6” Deep @ 250 FPM = 1.4” W.G. (350 Pascals)
Temperature Limit = 250°F (121°C)
Frame Construction = Galvanized, Stainless Steel, Particleboard, Fire Retardant Particleboard, Plywood and others.
Sealant = Polyurethane
Media = Glass Microfiber
Separators = Aluminum
UL 900 Class 1*
* Metal Frame Version
TRI -PURE� HEPA &
HEPAMAX� F ILTERS
FRAME
MEDIA
SEPARATOR
SEALANT
TRI-PURE� HEPA AND HEPAMAX� TECHNICAL DATA