This solicitation seeks proposals for preventative maintenance and repair services for heating, ventilation, and air conditioning systems in buildings on the North Campus of the VA Greater Los Angeles Healthcare System. The services include proactive preventative maintenance to keep HVAC systems fully functional and in optimal operating condition at all times. The contract will have a one-year base period and four one-year options. The place of performance is 11301 Wilshire Blvd, Los Angeles, CA. Proposals are due by July 15, 2020. Award will be made to the lowest priced offer from a veteran-owned small business that meets licensing and experience requirements.

View the file

Other files

File Type Posted
36C26220Q1012 0006_1.docx DOCX document
REVISED Building Equipment Inventory - fIlters-belts-etc.xlsx XLSX spreadsheet
36C26220Q1012 0005_1.docx DOCX document
SF1449 RFQ 36C26220Q1012 REVISED Changes.pdf PDF
36C26220Q1012 0004_1.docx DOCX document
36C26220Q1012 0003_1.docx DOCX document
36C26220Q1012 0002_1.docx DOCX document
RFI001 2019 Air Test Report _B113-B114-B115-B117-Research.pdf PDF
36C26220Q1012 0001_1.docx DOCX document
TRI-DIM TRI-CELL IVS literature.pdf PDF
Building 300 CUs - Part 2.xlsx XLSX spreadsheet
Building 300 ECs - Part 3.xlsx XLSX spreadsheet
36C26220Q1012_1.docx DOCX document
S02 SF1449 RFQ 36C26220Q1012.pdf PDF
TRI-DIM SYN-PAC E literature.pdf PDF
North Campus Building Listing.xlsx XLSX spreadsheet
TRI-DIM TRI-DEK XL 4-Ply literature.pdf PDF
Building Equipment Inventory - fIlters-belts-etc.xlsx XLSX spreadsheet
TRI-DIM HEPA Gasket Seal 1700-1 literature.pdf PDF
Building 300 Refr Evaps - Part 4.xlsx XLSX spreadsheet
Building Equipment Inventory.xlsx XLSX spreadsheet
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bldg_300_AC_Units

TypeLocationServesMfgModelSerialBeltFiltersAdd-l Info
PKGROOF210BCARRIER50HEQ006501V1809G50355A392-16*25*2
PKGROOFCARRIER50HEQ003301U1809G40351A372-16*25*2
PKGROOFNORTH ENTRANCECARRIER50HEQ003301U1809G40353A394-16*16*2
PKGROOF209CARRIER50HEQ006501HQ1809G50354A394-20*20*2
PKGROOFCARRIER50HEQ004501HQA372-16*25*2
PKGROOF207CARRIER50HEQ003301U1809G40352A372-16*25*2
PKGROOF209CARRIER50HEQ005501V1809G40321A362-16*25*2
PKGROOFCARRIER50HEQ0045011809G40381A372-16*25*2
PKGROOF2ND FLR ENTRANCECARRIER50HEQ004501V1809G40386A372-16*25*2
PKGROOF206CARRIER50HEQ006501HQ1809G50353A372-16*25*2
PKGROOFCARRIER50HEQ006501V1809G50356A394-16*16*2
PKGROOFCARRIER50HEQ004501HQ1809G40385A372-16*25*2
PKGROOFCARRIER50HEQ004501HQ1809G40384A372-16*25*2
PKGROOF209CARRIER50HEQ004501HQ1809G40383A362-16*25*2
PKGROOF218 OUTERCARRIER50HJQ0085213403G30617A514-16*20*2
PKGROOF216CARRIER50TCQA06A2A5A0A0A00511G20397A434-16*16*2
PKGROOFCARRIER50SZ0243014308G21330D-D1-20*20*2
PKGROOFTRANEWCC060F300BG3365PB52HD-D3-10*24*1
PKGGROUND119ARMSTRONGPGE10A30D050LA4A8498C24129D-D2-12*24*1
SPLITCUROOF218GTRANETWA036C300A1J19220750
AHU218 HALLTRANETWE036CC140A0G23829768D-D1-20*20*1230V
SPLITCUROOF218HTRANETWA048C300A1J17297051
AHU218 HALLTRANETWE048C140B2J15874946D-D1-20*20*1230V
SPLITCUROOF218NTRANETWA048C300A1J17297056
AHU218JTRANETWE048C140B2J14873942D-D1-20*20*1230V
SPLITCUGROUNDBSMNTELEVSANYOC095150801115V
AHUBASEMENTSANYOKS095118794WASH
SPLITCUGROUND106CARRIER38ARR06050909X90085
AHU106BRYANTFE4ANB0062508A86082D-D1-20*22*1
SPLITCUGROUND106CARRIER38ARR06050909X90091
AHU106BRYANTFE4ANB0060808A88047D-D1-20*22*1
SPLITCUGROUND106CARRIER38ARR06050909X90068
AHU106BRYANTFE4ANB0060908A85761D-D1-20*22*1
SPLITCUGROUND103WESTCARRIER38ARQ0125012709G40082
AHU103CARRIER40RMQ012B611HC2309U11125A394-16*24*2
SPLITCUGROUND103EASTCARRIER38ARR06052709G40082
AHU103BRYANTFV4BNB0062409A85616D-D1-20*22*1
SPLITCUGROUNDKITCH. WESTCARRIER38ARQ0121008G20128
AHUKITCHENCARRIER40RMQ012B611GC1508U09708A394-16*24*2
SPLITCUGROUNDKITCH. EASTCARRIER38ARQ0085010808G30111
AHUKITCHENCARRIER40RMQ008B611GC4807U36293A394-16*24*2
SPLITCUGROUNDBASEMENTCARRIER38QRR02431409X93073
AHUBASEMENTCARRIERFV4BNF0030809A83627D-D1-20*22*1
SPLITCUGROUNDBASEMENTTRANERAUJC30FBB030B0000000C10F03056
AHUBASEMENTTRANEMCCB014UA0D0UB000K10F57971B6416-16*20*4
SPLITCUGROUNDBCAREACARRIER38QRR024314107X90433
AHUBCAREACARRIERFV4BNF0033407A86482D-D1-20*22*1
SPLITCUGROUND120CARRIER38QRR02435007X90518
AHU120CARRIERFV4BNF0034407A83696D-D1-20*22*1
SPLITCUGROUND109CARRIER38QRR0243015007X90521
AHU109CARRIERFV4BNF0034407A86002D-D1-20*22*1
SPLITCUROOFCARTROOMCARRIER38ARQ0085012709G40082
AHU1STCARRIER40RMQ008B611GC4807U36296A394-16*24*2