Tech_PG8AC_Restarting-_Flushing_Filter_1.6_spec_b.pdf

PDF 1 MB Posted

Attached to
Water Cooler Filter Replacement -Term Contract
Solicitation number
052-MJ-0425
Issued by
Polk County, Florida

About this file

The document is a detailed, step-by-step technical instruction manual from Oasis Coolers for restarting and sanitizing a PG8AC water fountain, specifically focusing on the process of flushing and preparing the unit after a shutdown. The instructions are comprehensive, covering multiple stages including unplugging the unit, draining the cold tank, bypassing the filter (if applicable), performing flush cycles, reconnecting the filter, and sanitizing the exterior.

The manual provides precise technical guidance with visual illustrations for each step, requiring specific tools like a T15 Torx screwdriver, disinfectant wipes, latex/nitrile gloves, and a bucket. The procedure involves carefully depressurizing the system, draining and reflushing the tank, potentially bypassing and replacing the water filter, and thoroughly cleaning the unit's exterior. Technical support contact information is provided (1-800-646-2747 or techserv@oasiscoolers.com), indicating ongoing manufacturer support for the maintenance process.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Restarting PG8AC Water Fountain

Recommended Instructions for bringing a cooler back into service after being shut down.

Supplies Required

• Disinfectant wipes or food grade disinfectant

• Latex or nitrile gloves

• T 15 Torx Screwdriver

• Bucket

• ¼” union part# 028605-101

Unplug unit

Removing front cover (if necessary) to access electric plug Unplug from outlet

Prepping the Cooler

Shut off valves can differ. This is for example only.

ON

O

FF

Press dispense pad until water stops to depressurize

Bypass the Filter (if applicable)

Remove the tubing from the filter head

Using a Union Fitting, bypass the filter

Note:

Change filter cartridge at this time.

Draining the Cold Tank

Allow tank to drain completely into bucket.

*Note:

Some models may have a cap instead of a plug

Depress the collet and remove the drain plug

Closing the Tank Drain

Insert the plug into the union fitting to close the tank drain

Insert the cap onto the drain line to close the tank drain

1st Flush Cycle

Turn ON water supply Depress pad until water fills the cold tank and runs consistently, allow approximately 2 gallons

ON

O

Repeat Draining the Cold Tank

Shut off water supply Depressurize Remove drain plug on tank

Drain into bucket

2nd Flush Cycle

Turn ON water supply

ON

O

Run 2 more Gallons through the Unit

Reconnect the Filter (if applicable)

Reinsert the tubing in to filter head

Remove lines from union

Shut off water supply and depressurize the unit once more

Note:

It is recommended to properly flush the replacement filter cartridge before connecting to the cooler.

Flushing Complete

Run water by depressing the dispense pad.Turn ON water supply

ON

O

Plug Unit into Outlet

Sanitizing the Exterior

Clean the top of the unit, push pads and bubbler with disinfectant wipes

Technical Support

Call 1-800-646-2747