About this file

This document is a technical instruction manual from Oasis Coolers detailing the process for cleaning the condenser on a PG8AC water cooler. The manual provides step-by-step guidance for maintenance professionals or technicians, focusing specifically on how to access and clean the condenser to maintain optimal cooling system performance.

The document outlines the importance of condenser maintenance, explaining that dust, dirt, and debris can dramatically reduce the efficiency of the cooling system. The cleaning process requires two tools: a T-15 Torx bit and a shop vac. The instructions include removing the front and right side panels to access the condenser, then using the shop vac to thoroughly clean the condenser coils. After cleaning, the panels should be replaced, which should restore the unit to peak performance. Technical support is available by calling 1-800-646-2747 or emailing techserv@oasiscoolers.com.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cleaning the Condenser on a

PG8AC

Tools Required

• T-15 Torx Bit

• Shop vac

What does the Condenser do?

As the fan motor cycles it will draw air through the louvered side panel and across the condenser, this will dissipate the heat produced from the cooling system and keeps the unit operating at an optimal performance level

The Condenser will always be located on the right hand side of the cooler.

Air Flow Air Flow

Clean Condenser

Air Flow

Dirty Condenser Will Affect Performance

When the condenser gets clogged with dust, dirt and debris, this will have a dramatic effect on the efficiency of the cooling system.

Accessing the Condenser

Remove the front panel by loosening 2 screws at the bottom and taking out the 2 screws at the top of the panel

Loosen

Remove Loosen

Remove

Remove the right side panel by loosening 2 screws at the top and taking out the 2 screws at the bottom of the panel

Cleaning the Condenser

Use your shop vac to remove any dirt, dust or debris that may be trapped in the condenser coils. Once this has been thoroughly cleaned replace the side and front panels.

With a clean condenser the unit should be operating a peak performance