Swale Detail.pdf
PDF 336 KB Posted
- Attached to
- 3 Wilhenger Drive Exterior Painting Project
- Solicitation number
- 38337
- Issued by
- Middlesex County, Connecticut
About this file
This file contains a technical specification detail for a dry swale stormwater management system prepared for the Town of Marlborough, Connecticut. The document presents engineering specifications and design parameters for a stormwater drainage feature, including materials, dimensions, and installation requirements. The dry swale is designed with a maximum ponding depth of 36 inches during a 10-year storm event, reducing to 12 inches at the longitudinal midpoint and 18 inches at the downstream end. The specification requires non-woven filter fabric compliant with Connecticut Department of Transportation Standard Specifications M.08.01.19 (Drainage - Geotextiles), native grass or plants as preferred vegetation with alternative provisions for river stone or smooth crushed stone, 2:1 side slopes, and a 30-linear-foot perforated 6-inch HDPE underdrain sloped north to south at 5 percent gradient. The system includes 2-3 inch crushed stone supplemented with 1/2-inch drainage stone, with non-woven filter fabric applied to the sides of excavation only, and requires a minimum 24-inch separation to the seasonal high water table or bedrock.
The specification establishes detailed material and construction standards for stormwater management infrastructure but does not contain pricing information, set-asides, bidding requirements, or contract terms. This technical document appears to be a supporting exhibit or design specification that would accompany a larger construction or site development project for the Town of Marlborough, Connecticut, and would serve as reference material for contractors bidding on projects involving stormwater management systems.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2-3" CRUSHED STONE SUPPLEMENTED WITH 1/2" DRAINAGE STONE
NON-WOVEN FILTER FABRIC ON SIDES OF
EXCAVATION ONLY
UNDISTURBED NATIVE SOIL24" MIN SEPARATION
TO SEASONAL HIGH WATER
TABLE/BEDROCK
1. FILTER FABRIC : USE NON-WOVEN FILTER FABRIC THAT COMPLIES WITH STATE OF CONNECTICUT DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS, M.08.01.19
(DRAINAGE - GEOTEXTILES).
DRY SWALE DETAIL WITH UNDERDRAIN
N.T.S
BOTTOM WIDTH VARIES
ADJACENT ROADWAY
(WHERE APPLICABLE)
OVERFLOW STORM WSE
(MAX PONDING DEPTH : 36")
(10 YEAR STORM)
OVERFLOW STORM WSE (MAX
PONDING DEPTH : 12") AT
LONGITUDINAL MIDPOINT, 18 INCHES
AT DOWN STREAM END OF SWALE
NATIVE GRASS/PLANTS PREFERRED
(RIVER STONE OR SMOOTH
CRUSHED STONE MAY BE USED
2:1 SIDE SLOPES
24"
24"
30 LF PERFORATED 6" HDPE UNDERDRAIN SLOPED N TO S
marrenj Line marrenj Oval marrenj Line marrenj Architect 5% Pipe Slope
File details come from the government source that posted it. Updated .