Standard TSBLDG Part 1.pdf

PDF 476 KB Posted

Attached to
751/22021. JBB; Palms Book & Indian Lake SP - Park Imprvemnts
Solicitation number
RFP - 171 - 230000002322
Issued by
Schoolcraft County, Michigan

About this file

The document provided appears to be a floor plan for a Shower Building Improvements project at the Straits State Park in St. Ignace, Mackinac County, Michigan. The project is being undertaken by the Michigan Department of Technology, Management and Budget, State Facilities Administration Design and Construction Division. The floor plan includes details such as dimensions, wall types, fixtures, and drainage requirements for the proposed facility.

The related state and local contract opportunity is identified as 751/22021. JBB; Palms Book & Indian Lake SP - Park Imprvemnts, under the jurisdiction of Schoolcraft County, Michigan. The contract opportunity likely includes the construction of the shower building and other park improvements, though additional details regarding the full scope of work, bidding requirements, and contract terms are not provided in the documentation presented.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PORCH A

1'-4" 10'-4" 1'-4"1'-4" 1'-4"10'-4"5'-8"

8"3'-4" 3'-0" 3'-4"3'-4"8" 3'-4"

1'-

24'-0"

1'-

8"

1'-

7' -8

9'-8"

5'-0"

1'-

1'-

1'-4"1'-4" 10'-4"1'-4" 10'-4"

24'-8"

3'-4"5'-4" 7'-4"3'-4"

7'-4"

3'-0"

7'-4"

2' -8

31'-4"

2' -8

1'-

2' -8

1'-

1'-

7'-4"

2' -0

1'-

8"8" 7'-4"

2' -8

1'-

1'-

2' -8

1'-

1'-

1'-

2' -0

1'-

1'-

2' -8

1'-

2' -8

1'-

2' -8

1'-

1'-

5'-8"4'-8"4'-8"8"5'-8"

3'-4"8"

8"

24'-0"

7' -0

4"

6'-0"1'-4"

1'-8"3'-4"1'-8"

1'-

7'-0"

1'- 2"

3'-4"

8"

1'-

1'-

1'-

1'-

PORCH B

PORCH C

MEN'S

WOMEN'S

FAMILY/ADA

LAVATORY

ADA UNISEX

SHOWER

UNISEX

SHOWER

UNISEX

SHOWER

F.D.

H.B.

3" F.D.

2 1

33 3

7TYP.

7 TYP.

106B

110109108107

106A 104105

A

B

B

B

B

25 25

F.D.

F.D.F.D. F.D. F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

A4

A4

A 4

B

B

B

A 4

A 4

A401

1 1 1

34 34 34 34

A401

A 4

2 2

F.D.

F.D.

ADA UNISEX

SHOWER

UTILITIES AND

STORAGE ROOM

A401

CJ

CJCJ

CJ

CJ

CJ CJ

0"

0"

0" 0"

0"

0"

0"

0"0"

-.83"

0"0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

-.37"

-.95"

-1.08"

-.75"

-.83"

0"

-.89"

0"

0"

-.91" min.

4" / ft.

(typ.)

m in

1/ f t

(t y p m in

1/ f t

(t y p

0"

0" c.j.

4"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"0"

0"

0"

0"0"

0"

0"

0"

0"

0"0"

-.37

30 30 30

30303030 m in

1/ f t

(t y p min.

1/4" / ft.

(typ.)

min.

1/4" / ft.

(typ.)

m in

1/ f t

(t y p m in

1/ f t

(t y p

31 31 31

A401

-.37"-.37"

-.66" -.58" -.66"-.58"

30 30

303030

-.89"

-1.08"

-1.08"

A401

0" -.91"

-.75"

7' -0

2' -4

1 6"x6" SOLID CEDAR hand hone

WOOD COLUMN ON 16" X 16" MASONRY

COLUMN BASE AND PRE-CAST CAP.

STAIN WOOD COLUMN. see det.

#c/s201.

4" REINFORCED CONCRETE SLAB

SIDEWALK. SLOPE SIDEWALK AWAY

FROM BUILDING AT MIN. 1/4" PER 1'-0".

ALUMINUM DOOR AND FRAME.

ALUMINUM WINDOW UNIT see sheet a601 for more information.

DRINKING FOUNTAINS, provide 1/4" STEEL mounting plate on inside matching exterior mounting plate.

wall mounted hand dryer MOUNTED ON 1/4" solid surface splash guard.

18" X 36" wall mounted mirror. 1 per sink (typ.)

SOLID SURFACE COUNTERTOP WITH

SPLASH AND integrally sinks SEE

DET. #6/A401.

soap dispensers.

wall hooks SEE INTERIOR ELEVATIONS a501 FOR LOCATIONS

AND MOUNTING HEIGHTS.

toilet partitions.

WALL MOUNTED URINAL.

WALL MOUNTED URINAL SCREEN.

WALL MOUNTED TOILET.

toilet paper dispenser mounted To wall or partition.

36" horizontal grab bar.

42" horizontal grab bar.

18" vertical grab bar.

fold-up wall mounted changing table. mount 34" max. to top of table surface

Sharp OBJECT DISPOSAL - WALL

MOUNTED.

SANITARY NAPKIN DISPENSER - WALL

MOUNTED.

wall mounted HOSE REEL.

WALL MOUNTED MOP RACK AND

SHELF. MOUNT SHELF 6'-0" A.F.F. TO

TOP OF SHELF.

MOP SINK.

barrier free roLL-in shower seat.

48" horizontal grab bar.

30" GRAB BAR

36" X 12" WALL MOUNTED STAINLESS

STEEL FIXED BENCH with perforated top.

24" horizontal towel bar. mount at 36" a.f.f.

CONTROL JOINT. reference detail on s101.

4" REINFORCED CONCRETE ON

COMPACTED BASE. PROVIDED

POSITIVE DRAINAGE TO FLOOR

DRAINS.

INDICATES LINE OF 12" CONCRETE

BLOCK FOOTING wall BELOW.

indicates line of 8" concrete block wall.

INDICATES WALL MOUNTED SHOWER

UNIT. see sheet a501 for height

STAINLESS STEEL SINK - REFER TO

PLUMBING PLANS

FLOOR MOUNTED WATER HEATER

CONSTRUCTION NOTES

A. all dimensions are from face of block to face of block or faced of finished material to face of finished material..

B. FOR MOUNTING HEIGHTS REFER TO INTERIOR

ELEVATIONS AND SHEET CS101.

C. refer to sheet a601 for accessories schedule. GENERAL CONTRACTOR TO

INSTALL ALL OWNER SUPPLIED ITEMS.

D. all exposed concrete block corners to be bullnose as indicated on plans. if block does not come with bullnose corners then bullnose will need to be completed in field to match standard CMu Bullnose.

E. grout block solid below grade to first course above grade, above all openings, top course and at mounting locations for bench's and changing table.

F. concrete block headers are to be lintel block or concrete lintel. bottom face to be solid.

G. general contractor to require the coordination between all trades to provide a proper floor finish and drainage.

GENERAL NOTES

WALL TYPES

8" insulted CONCRETE BLOCK W/ #4 @ 40" O.C.

HORIZ WITH HORIZ REINFORCING @ 16" O.C.

VERT.(OMNI Block), SEE DETAILS SHT. S301 (SEE

EXTERIOR ELEVATIONS FOR FINISHES)

REFER TO SHEET A601

WINDOW TYPES

2 8" CONCRETE BLOCK W/ #4 @ 40" O.C. HORIZ

WITH HORIZ REINFORCING @ 16" O.C. VERT.

(INTERIOR WALLS)

A

REFER TO SHEET A601B

EXTERIOR BRICK

REFER TO PROJECT SPECIFICATIONS FOR

MORE INFORMATION

Floor slopes to floor drains are to meet the requirements of the Michigan Plumbing Code and the American with Disabilities Act. Positive water drainage to drain be maintained and accessibility considerations are to be met to the best of the contractor's ability

Slope percentages and distance of fall shown on drawings are approximate and field conditions will alter these dimensions and slope percentages. Floor conditions to be confirmed in field by the general contractor and sub-contractor to verify that the code requirements are met. Any discrepancies shall be identified, and the Owner's project representative notified prior to any floor grinding.

Michigan Plumbing Code requires shower floors to be sloped (2-percent slope) per IPC 416.5.2

ADA requirements that maximum cross slope is 1:48 (2-percent slope) per ICC A117.1-2009 Section 403.3

Notes Regarding Floor Slab Sloping to Drains

FLOOR PLAN

SCALE: 1/4"=1'-0"

JC

/E

N G

B Y

PR

O

JE

C

T N

O

IN

D

EX

PC

A

D R

AW

N

B Y

D

ES

IG

N

ED

B

Y

R

EV

IE

W

D

AT

E

-0

BS

G

M

EH

C

IV

IL

E

N G

IN

EE

R

TD

G

-9

.0

PR

O

JE

C

T D

ES

C

R

IP

TI

O

N

ST

R

AI

TS

S

TA

TE

P

AR

K

SH

O

W

ER

B U

IL

D

IN

G

IM

PR

O

VE

M

EN

TS

ST

. I G

N

AC

E M

AC

KI

N C

C O

U N

TY

PL

UR

IB

U

E S

U N U

M

C I

R C

U M

S P

I C

E

S I

Q U

E R E

I S

P E

N I

N S

U L

A M

A M

OE

N

A M

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

Ph as e

- 5

0%

/1 /2

Ph as e

- 9

0%

/5 /2

Ph as e

- B id D oc um en ts

5/

/2

C O

N C

R

ET

E

SL

AB

P

LA

N

AN

D

F

LO

O R

P

LA

N

EA

ST

A1

E

CONCRETE SLAB PLAN

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

NF

AutoCAD SHX Text

ENGINEERS

AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners

AutoCAD SHX Text 46777 Woodward Avenue Pontiac, MI 48342-5032 Tel. (248) 332-7931 Fax. (248) 332-8257