Indian Lake State Park Atlas ACM LCP Report.pdf
PDF 2 MB Posted
- Solicitation number
- RFP - 171 - 230000002322
- Issued by
- Schoolcraft County, Michigan
About this file
This document is a pre-demolition asbestos and limited lead-based paint survey for the toilet/shower building at Indian Lake State Park in Manistique, Michigan, prepared by Atlas Technical Consultants LLC for the Michigan Department of Natural Resources. The survey was conducted on May 16, 2022 and found no asbestos-containing materials in the building, but identified one exterior paint sample with lead levels above the detection limit. The survey provides recommendations for handling any additional suspect materials discovered during future demolition activities.
The related state and local contract opportunity is for park improvements at Palms Book State Park and Indian Lake State Park, in Schoolcraft County, Michigan. The contract was solicited by the Michigan Department of Natural Resources. No further details about the specific project scope, timeline, or procurement process are provided in the given information.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRE-DEMOLITION ASBESTOS AND LIMITED LEAD-BASED
PAINT SURVEY
INDIAN LAKE STATE PARK
188BS22313
8970 W. County Road 442
Manistique, Michigan 49854
PREPARED FOR:
Michigan Department of Natural Resources
PREPARED BY:
Atlas Technical Consultants LLC 46555 Humboldt Drive, Suite 100 Novi, Michigan 48377 June 28, 2022
Page | 1
46555 Humboldt Drive, Suite 100 Novi, Michigan 48377
(248) 669-5147 | oneatlas.com
June 28, 2022
DENNIS GREEN
SUPERVISOR
INDIAN LAKE STATE PARK
Subject: Pre-Demolition Asbestos and Limited Lead-Based Paint Survey Toilet/Shower Building Indian Lake State Park
Manistique, Michigan 49854
Dear Mr. Green:
Atlas is pleased to present this report detailing the finding of the pre-demolition asbestos and limited lead-based paint survey performed at the above referenced site. The purpose of this sampling was to identify and collect samples of suspect asbestos containing (ACBM’s) and lead-based paint (LBP) building materials prior to demolition activities.
The pre-demolition asbestos and lead-based paint sampling was conducted on January 27, 2022 by Industrial Hygienist, Mr. Andrew Delodder, State of Michigan certified asbestos inspector. The sampling was conducted in accordance with sampling criteria specified in the Occupational Safety and Health Administration’s (OSHA) Asbestos Construction Industry Standard (29 CFR 1926.1101), and the Asbestos Hazard and Emergency Response Act of 1987 (AHERA).
If you have any questions, please call us at 248.669.5140.
Respectfully submitted, Andrew Delodder Ryan Rae State of Michigan Asbestos Inspector Project Manager
Page | i
CONTENTS
EXECUTIVE SUMMARY
1. INTRODUCTION
1.1 Purpose
1.2 Pre-Demolition Asbestos Survey
2. GENERAL SITE CONDITIONS
2.1 General Property and Building Information
2.2 Exterior Finish Descriptions
2.3 Interior Building Descriptions
3. PRE-DEMOLITION ASBESTOS SURVEY
3.1 Homogeneous Areas
3.2 Hazard Assessment Factors
3.3 Laboratory Analytical Methodology
3.4 Sampling Results
4. LEAD-CONTAINING PAINT SAMPLING
5. CONCLUSIONS AND RECOMMENDATIONS
5.1 Asbestos Containing Materials
5.2 Lead-Containing Paint Containing Materials
6. ASSUMPTIONS AND LIMITATIONS
TABLES
Table 3-1 ACM Sampling Results
Table 4-1 Lead-Based Paint Sampling Results
APPENDICES
Appendix A Asbestos Laboratory Report Appendix B Lead-Based Paint Laboratory Report Appendix C Qualifications
EXECUTIVE SUMMARY
Atlas representative Mr. Andrew Delodder completed the pre-demolition asbestos and limited lead-based paint survey of the toilet/shower building, located at Indian Lake State Park, 8970 W. County Road 442, Manistique, Michigan on May 16, 2022.
Thirty-six (36) asbestos bulk samples, taken from thirteen (13) homogenous areas, were collected and submitted for analysis by PLM. Fifty-one (51) sample layers were analysed. The results of laboratory testing during the pre-demolition asbestos survey conducted at the property indicate that none (0) of the materials sampled were found to contain asbestos.
Two (2) composite samples of paint, taken from exterior areas of the building, were collected and submitted for analysis by Flame AAS. The results of laboratory testing during the limited lead-containing paint sampling conducted at the property indicate that one (1) sample contained levels of lead greater than the method detection limits.
If any additional materials are discovered during renovation/demolition activities, such materials must be assumed to contain asbestos until sampling and analysis proves otherwise.
1. INTRODUCTION
1.1 Purpose
The purpose of this project was to conduct a pre-demolition asbestos survey of the toilet/shower building at Indian Lake State Park, located at 8970 W. County Road 442, Manistique, Michigan (herein referred to as “the property”).
1.2 Pre-Demolition Asbestos Survey
The scope of the pre-demolition asbestos survey included the following:
Review of existing asbestos reports for the building, if available;
Survey of the property building(s);
Identification of accessible suspect asbestos-containing materials (ACMs);
Collection and analysis of bulk samples of suspect friable and non-friable materials; and
2. GENERAL SITE CONDITIONS
2.1 General Property and Building Information
The purpose of this project was to conduct a pre-demolition asbestos and lead-based paint survey of the toilet/shower building, located at 29881 Co. Road 407, Manistique, Michigan (herein referred to as “the property”).
General property and building information is presented in the following table:
General Property and Building Information
Date of Inspection: May 16, 2022
Inspectors Andrew Delodder, Inspector # A48677
Property Address: 8970 W. County Road 442, Manistique, Michigan 49854
Property Owner Michigan Department of Natural Resources
Building Description: Toilet/Shower Building
Building Square Footage
(Approximate):
~1,310 SF
2.2 Exterior Finish Descriptions
The exterior of the building included wood siding with a shingled-sloped roof.
2.3 Interior Building Descriptions
The interior finishes of the building included floor tile, wood, plaster, and ceramic floor tiles.
3. PRE-DEMOLITION ASBESTOS SURVEY
Atlas representative Mr. Andrew Delodder conducted the pre-demolition asbestos inspection of the property building on May 16, 2022. Mr. Delodder is a State of Michigan Certified Asbestos Inspector’s (Certification
No. A48677). The building was visually inspected for the presence of building materials that are suspected to contain asbestos. Bulk samples of suspect ACMs were collected and placed into individual containers for transport to a National Voluntary Lab Accreditation Program (NVLAP)-accredited laboratory for analysis.
Materials typically known as non-asbestos items (i.e. fibrous glass, foam rubber, wood, etc.) were not sampled. The asbestos inspection consisted of the following three basic procedures:
> Conducting a visual inspection of the structures;
> Identifying homogeneous areas (HAs) of suspect surfacing, thermal system insulation, and miscellaneous materials; and
> Sampling accessible, friable and non-friable suspect materials.
3.1 Homogeneous Areas
Prior to collecting any samples, homogenous areas (HAs) were identified. A homogeneous sampling area can be described as one or more areas of material that are similar in appearance and texture and that have the same apparent installation date, appearance and function. Actual number of samples collected from each homogeneous sampling area may vary, based on the type of material and professional opinion of the inspector.
3.2 Hazard Assessment Factors
From the list of suspect homogeneous areas, a physical assessment was performed for each material on the list. A physical assessment includes evaluating the condition, assessing the potential for disturbance, and determining the friability of each material. By definition, "friable" materials are those that can be crumbled or reduced to powder by hand pressure when dry. Each material identified was further classified into one of three categories: surfacing materials, thermal systems insulation (TSI) and miscellaneous materials. Each of the three categories have specific sampling requirements, outlined below.
Surfacing Materials: Refers to spray-applied or troweled surfaces such as plaster ceilings and walls, fireproofing, textured paints, textured plasters, and spray-applied acoustical surfaces.
Thermal System Insulation: Refers to insulation used to inhibit heat gain or loss on pipes, boilers, tanks, ducts, and various other building components.
Miscellaneous Materials: Refers to friable and non-friable products and materials that do not fit in any of the above two categories such as resilient floor covering, baseboards, mastics, adhesives, roofing material, caulking, glazing, and siding. This category also contains wallboard and ceiling tile.
All materials were assessed related to their condition in one of the three categories: good (intact), fair
(damaged) or poor (significantly damaged) per Title 40 Code of Federal Regulations Part 763. Material with localized, significant damage was also assessed as poor.
3.3 Laboratory Analytical Methodology
Bulk samples were analysed by Environmental Testing Laboratories, Inc. (ETL) using polarized-light microscopy (PLM) and dispersion staining (Method Reference: 40 CFR Part 763, Volume 47, No. 103, May
27, 1982 pg. 23376). This laboratory participates in the National Voluntary Laboratory Accreditation Program
(NVLAP #201028-0), a quality assurance program for PLM analysis, and is accredited by the National Institute of Standards and Technology (NIST) as well as accreditation requirements under 15 CFR Part 25.
Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in
Appendix A. Positive sample results are reported in percent asbestos by volume of the sample and the type of asbestos material within the sample. Other common non-asbestos components may also be noted on the analytical reports. Inspector and laboratory accreditations are provided in Appendix C.
3.4 Sampling Results
Bulk samples were collected from the site building and analysed by polarized light microscopy (PLM), EPA
Method 600/R-93/116. None of the materials sampled was found to contain concentrations of asbestos.
The following table provides a summary of accessible suspect and confirmed ACMs from the Site buildings:
Table 3-1 ACM Sampling Results
TOILET/SHOWER BUILDING
8970 W. COUNTY ROAD 442
MANISTIQUE, MICHIGAN 49854
SAMPLED: MAY 16, 2022
Sample ID/Material Location of Materials
Material Condition Friable
Yes/No
Estimated Quantity
Asbestos Content
1-CC-A,B,C
Building Exterior, Men’s and Women’s
Restrooms, Shower Rooms, Maintenance Room
Concrete Chip – Poured Concrete
Floor Good No 1800 SF ND
2-CC-A,B,C
Building Exterior –
West Side
Concrete Chip – Concrete Walkway
Patching Good No 5 SF ND
3-GM-A,B,C Shower Floor Ceramic Tile, Grout, Mortar
Good No 200 SF ND
4-BM-A,B,C
Restrooms and Shower Rooms
Brick Mortar – Ceramic Block
Walls Good No 2170 SF ND
5-RM-A,B,C Roof Roofing Material – Asphalt Shingles
Good No 1310 SF ND
6-IC-A,B,C Ceiling Perimeter Interior Caulk Good No 130 LF ND
7-FD Exterior Fire Door Good No 7 Doors Assumed
8-EC-A,B,C
Exterior Window Frames, Door Frames, and
Roofline
Exterior Caulk Good No 400 LF ND
9-GM-A,B,C
Men’s and Women’s
Restrooms
Ceramic Tile, Grout, Mortar (6” floor tile)
Good No 800 SF ND
10-GM-A,B,C
Men’s and Women’s
Restrooms
Ceramic Tile, Grout, Mortar
(2” countertop tile) Good No 80 SF ND
11-IC-A,B,C
Men’s Bathroom (around urinals)
Interior Caulk – White
Good No 20 LF ND
12-CA-A,B,C
Under Formica Stall
Dividers Construction
Adhesive Good No 180 SF ND
13-PL-A,B,C Maintenance Room Plaster on Mesh Good No 60 SF ND
ND: None Detected
In the event additional suspect material is discovered during renovation activities, this material should be treated as presumed asbestos-containing material (PACM) in accordance with regulations 29 CFR
1926.1101 and 1910.1001 and other applicable state and local regulations and either sampled to confirm or nullify asbestos content or be treated as ACM and handled accordingly.
4. LEAD-CONTAINING PAINT SAMPLING
Atlas representative Mr. Andrew Delodder conducted the lead-containing paint (LCP) sampling of the property building on May 16, 2022. The sampling included physical sampling of paint coatings that were deemed representative of the predominant paint coatings observed.
Two (2) paint chip samples were collected and submitted to Accurate Analytical Testing Laboratory, 30105
Beverly Road, Romulus, Michigan for lead analysis. Bulk samples were analyzed using the Environmental
Protection Agency's Test Method SW 846 -7420 and 3050B using Flame AAS to determine lead concentration in percent (%) by weight. Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in Appendix B. Inspector and laboratory accreditations are provided in
Appendix C.
The following table provides a summary of the LBP sampling:
Table 4-1 Lead-Containing Paint Sampling Results
TOILET/SHOWER BUILDING
29881 Co. Road 407
MANISTIQUE, MICHIGAN 49854
SAMPLED: JANUARY 27, 2022
Sample ID Sample Location Sample
Compound Condition Color
Estimated Quantity
Lead Content (%)
1 LBP Exterior Wood Good Brown Unquantified 0.0025
S LBP Door Frames Metal Good Light Brown Unquantified <0.0018
5. CONCLUSIONS AND RECOMMENDATIONS
5.1 Asbestos Containing Materials
The results of laboratory testing during the pre-renovation asbestos survey conducted at the property indicate that none (0) of the materials sampled was found to contain asbestos.
If any additional materials are discovered during renovation/demolition activities, such materials must be assumed to contain asbestos until sampling and analysis proves otherwise.
5.2 Lead-Containing Paint Containing Materials
Two (2) composite samples of paint, taken from exterior areas of the buildings, were collected and submitted for analysis by Flame AAS. The results of laboratory testing during the limited lead-containing paint sampling conducted at the property indicate that one (1) sample contained levels of lead greater than the method detection limits. Therefore, the OSHA lead in construction standard would not apply.
The presence of lead-containing paint requires, under OSHA 1926.62 requirements, that the contractor performing renovation, surface preparation, and other activities that impact or potentially impact the lead-coated components, evaluate potential worker exposures to airborne lead. This evaluation can be based, for the specific activities denoted in 1926.62, on objective data obtained by the contractor on other, similar, worksites within the prior calendar year. In addition, lead-containing paint and lead-coated waste and construction debris must be evaluated and, on a case-by-case basis depending on this evaluation, quantitative analysis be performed on these waste steams to ensure compliance with EPA waste disposal regulations.
The presence of lead-containing paint and/or LBP does not, in itself, trigger regulatory compliance actions.
However, when these materials are disturbed, the requirements of OSHA (1926.1101) and EPA may become operative. Appropriate actions in terms of removal methods, emissions control, worker protection, and waste disposal should be considered by the general contractor and applicable subcontractors while completing renovation activities.
6. ASSUMPTIONS AND LIMITATIONS
The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during the NESHAP inspections conducted on May 16, 2022, performed by
Atlas. Selection of sample locations and frequency of sampling were based on EPA Guidance documents, Atlas’s observations, and the assumption that building vintage and renovation history information presented to Atlas allowed the proper designation of homogenous materials for each building.
This document does not contain the elements necessary for an Abatement Work plan, and this document does not contain, nor should it take the place of technical specifications for ACM removal.
Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other statements either expressed or implied. This report does not warrant against changes to material from future operations or conditions, nor does it warrant against operations or conditions against present ACM material in locations not investigated.
The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users, and use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user.
APPENDIX A
ASBESTOS LABORATORY REPORT
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
Atlas - Novi
46555 Humboldt Dr. Suite 100
Novi, Michigan 48377
Project Location:
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
Client Project: 188BS22313
248048ETL Job:
Report Date: 5/23/2022
Robert Smith
Lab Sample Number Client Sample Number Sample Type Completed
1349322 Asbestos01-CC-A 05/23/2022
1349323 Asbestos01-CC-B 05/23/2022
1349324 Asbestos01-CC-C 05/23/2022
1349325 Asbestos02-CC-A 05/23/2022
1349326 Asbestos02-CC-B 05/23/2022
1349327 Asbestos02-CC-C 05/23/2022
1349328 Asbestos03-GM-A 05/23/2022
1349329 Asbestos03-GM-B 05/23/2022
1349330 Asbestos03-GM-C 05/23/2022
1349331 Asbestos04-BM-A 05/23/2022
1349332 Asbestos04-BM-B 05/23/2022
1349333 Asbestos04-BM-C 05/23/2022
1349334 Asbestos05-RM-A 05/23/2022
1349335 Asbestos05-RM-B 05/23/2022
1349336 Asbestos05-RM-C 05/23/2022
1349337 Asbestos06-IC-A 05/23/2022
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type Completed
1349338 Asbestos06-IC-B 05/23/2022
1349339 Asbestos06-IC-C 05/23/2022
1349340 Asbestos08-EC-A 05/23/2022
1349341 Asbestos08-EC-B 05/23/2022
1349342 Asbestos08-EC-C 05/23/2022
1349343 Asbestos09-GM-A 05/23/2022
1349344 Asbestos09-GM-B 05/23/2022
1349345 Asbestos09-GM-C 05/23/2022
1349346 Asbestos10-GM-A 05/23/2022
1349347 Asbestos10-GM-B 05/23/2022
1349348 Asbestos10-GM-C 05/23/2022
1349349 Asbestos11-IC-A 05/23/2022
1349350 Asbestos11-IC-B 05/23/2022
1349351 Asbestos11-IC-C 05/23/2022
1349352 Asbestos12-CA-A 05/23/2022
1349353 Asbestos12-CA-B 05/23/2022
1349354 Asbestos12-CA-C 05/23/2022
1349355 Asbestos13-PL-A 05/23/2022
1349356 Asbestos13-PL-B 05/23/2022
1349357 Asbestos13-PL-C 05/23/2022
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Lab Sample Number Client Sample Number Sample Type Completed
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 51Emily Nowacki
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349322
01-CC-A
PLM 98% OtherPLM 2% CelluloseGrayConcrete Chip
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349323
01-CC-B
PLM 98% OtherPLM 2% CelluloseGrayConcrete Chip
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349324
01-CC-C
PLM 98% OtherPLM 2% CelluloseGrayConcrete Chip
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349325
02-CC-A
PLM 98% OtherPLM 2% CelluloseGrayConcrete Chip
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349326
02-CC-B
PLM 98% OtherPLM 2% CelluloseGrayConcrete Chip
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349327
02-CC-C
PLM 98% OtherPLM 2% CelluloseGrayConcrete Chip
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349328
03-GM-A
PLM 97% OtherPLM 3% CelluloseBrownCeramic Tile
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349328
03-GM-A
PLM 97% OtherPLM 3% CelluloseBrownGrout
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349328
03-GM-A
PLM 97% OtherPLM 3% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-3 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349329
03-GM-B
PLM 97% OtherPLM 3% CelluloseBrownCeramic Tile
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349329
03-GM-B
PLM 97% OtherPLM 3% CelluloseBrownGrout
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349329
03-GM-B
PLM 97% OtherPLM 3% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-3 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349330
03-GM-C
PLM 97% OtherPLM 3% CelluloseBrownCeramic Tile
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349330
03-GM-C
PLM 97% OtherPLM 3% CelluloseBrownGrout
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349330
03-GM-C
PLM 97% OtherPLM 3% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-3 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349331
04-BM-A
PLM 98% OtherPLM 2% CelluloseRedBrick
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349331
04-BM-A
PLM 98% OtherPLM 2% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349332
04-BM-B
PLM 98% OtherPLM 2% CelluloseRedBrick
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349332
04-BM-B
PLM 98% OtherPLM 2% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349333
04-BM-C
PLM 98% OtherPLM 2% CelluloseRedBrick
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349333
04-BM-C
PLM 98% OtherPLM 2% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349334
05-RM-A
PLM 99% OtherPLM 1% CelluloseGrayRoofing Material-Asphalt Shingle
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349335
05-RM-B
PLM 99% OtherPLM 1% CelluloseGrayRoofing Material-Asphalt Shingle
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349336
05-RM-C
PLM 99% OtherPLM 1% CelluloseGrayRoofing Material-Asphalt Shingle
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349337
06-IC-A
PLM 99% OtherPLM 1% CelluloseWhiteInterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349338
06-IC-B
PLM 99% OtherPLM 1% CelluloseWhiteInterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349339
06-IC-C
PLM 99% OtherPLM 1% CelluloseWhiteInterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349340
08-EC-A
PLM 98% OtherPLM 2% CelluloseBrownExterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349341
08-EC-B
PLM 98% OtherPLM 2% CelluloseBrownExterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349342
08-EC-C
PLM 98% OtherPLM 2% CelluloseBrownExterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349343
09-GM-A
PLM 97% OtherPLM 3% CelluloseTanCeramic Tile
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349343
09-GM-A
PLM 97% OtherPLM 3% CelluloseTanGrout
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349343
09-GM-A
PLM 97% OtherPLM 3% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-3 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349344
09-GM-B
PLM 97% OtherPLM 3% CelluloseTanCeramic Tile
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349344
09-GM-B
PLM 97% OtherPLM 3% CelluloseTanGrout
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349344
09-GM-B
PLM 97% OtherPLM 3% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-3 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349345
09-GM-C
PLM 97% OtherPLM 3% CelluloseTanCeramic Tile
Non-Fibrous
Homogenous Layer-1 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349345
09-GM-C
PLM 97% OtherPLM 3% CelluloseTanGrout
Non-Fibrous
Homogenous Layer-2 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349345
09-GM-C
PLM 97% OtherPLM 3% CelluloseGrayMortar
Non-Fibrous
Homogenous Layer-3 Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349346
10-GM-A
PLM 98% OtherPLM 2% CelluloseGrayMortar
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349347
10-GM-B
PLM 98% OtherPLM 2% CelluloseGrayMortar
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349348
10-GM-C
PLM 98% OtherPLM 2% CelluloseGrayMortar
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349349
11-IC-A
PLM 98% OtherPLM 2% CelluloseWhiteInterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349350
11-IC-B
PLM 98% OtherPLM 2% CelluloseWhiteInterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349351
11-IC-C
PLM 98% OtherPLM 2% CelluloseWhiteInterior Caulk
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
PLM None Detected 1349352
12-CA-A
PLM 95% OtherPLM 5% CelluloseBrownConstruction Adhesive
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349353
12-CA-B
PLM 95% OtherPLM 5% CelluloseBrownConstruction Adhesive
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349354
12-CA-C
PLM 95% OtherPLM 5% CelluloseBrownConstruction Adhesive
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349355
13-PL-A
PLM 98% OtherPLM 2% CelluloseBrownPlaster - on mesh
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349356
13-PL-B
PLM 98% OtherPLM 2% CelluloseBrownPlaster - on mesh
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
PLM None Detected 1349357
13-PL-C
PLM 98% OtherPLM 2% CelluloseBrownPlaster - on mesh
Non-Fibrous
Homogenous Analyst: Dave Cousino
Date Analyzed : 05/23/2022
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Novi,Michigan 48377
Atlas - Novi
46555 Humboldt Dr. Suite 100
Indian Lake State Park
8970W County Rd 442, Manistique MI 49854
ETC Job :
Client Project :
248048
188BS22313
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
05/12/2022
05/18/2022
Date Collected :
Date Received :
Lab Supervisor/Other Signatory
Dave Cousino
Analyst:
400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")
Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples
Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples
EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials
EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples
A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
APPENDIX B
LEAD-BASED PAINT REPORT
Certificate of Analysis: Lead In Paint by EPA SW-846 7420 and 3050B*
Client Project :
797769
05/18/2022
05/18/2022
Date Reported :
Date Analyzed :
Date Received :
AAT Project :
Phone :
Email :
Fax : 734-727-7165 dawn.winther@atcassociates.com
248-669-5140
Dawn Winther
ATC Group Services LLC
Attn :
Client :
8970 W COUNTY ROAD 442 INDIAN LAKE STATE PARKProject Location :
188BS22313
Novi, MI 48377
46555 Humboldt Dr.
30105 Beverly Road
Romulus, MI 48174
Ph: 734-629-8161; Fax: 734-629-8431
Sampling Date : 05/12/2022
05/19/2022
Lab Sample ID Result Lead
(% by weight) PPMSample DescriptionClient Code
Calculated R L
(% by weight)
1 LBP EXT BROWN PAINT7441442 25 0.0025 0.0008
S LBP LGHT BRWN PAINT ON DOOR FRAMES7441443 <18 <0.0018 0.0018
Analyst Signature
Derek Kibler
797769 AAT Project:Date Printed: 05/19/2022 4:21AM
RL= Reporting Limit * For true values assume (2) significant figures. The method and batch QC is acceptable unless otherwise stated. Current
EPA/HUD Interim Standard for lead in paint samples is: 5000 PPM (parts per million) or ug/g which is equivalent to 0.5% by weight. AAT internal sop
S203. The laboratory operates in accord with ISO 17025 guidelines and holds limited scopes of accreditation under AIHA-LAP and NY State DOH
ELAP programs. These results are submitted pursuant to AAT LLC current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions.Analytical results relate to the samples as received by the lab. AAT will not assume any liability or responsibility for the manner in which the results are used or interpreted. Reproduction of this document other than in its entirety is not permitted. All Quality control requirements for the samples this report contains have been met. AAT does not blank correct reported values. Sample data apply only to items analyzed. Samples are stored for 15 days following report date. *= Validated modified method
AIHA LAP- Lab ID #100986, NY State DOH ELAP -Lab ID #11864, State of Ohio- Lab ID # 10042
ATC Group Services LLCTo :
Attn :
Phone :
AAT Project :
Client Project :
Date Reported :
Project Location :
Email :Dawn Winther
248-669-5140 dawn.winther@atcassociates.com
797769
188BS22313
8970 W COUNTY ROAD 442 INDIAN LAKE STATE PARK
46555 Humboldt Dr.
Novi, MI 48377
30105 Beverly Road
Romulus, MI 48174
Ph: 734-629-8161; Fax: 734-629-8431
05/19/2022
Sample CompletedAnalysis RequestedClient Code Analyst
7441442 05/18/2022Lead Paint1 LBP Derek Kibler
7441443 05/18/2022Lead PaintS LBP Derek Kibler
Quality Assurance Coordinator - Stephen NorthcottReviewed By
797769 AAT Project:Date Printed: 05/19/2022 4:21AM
This report is intended for use solely by the individual or entity to which it is addressed. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify AAT immediately. Thank you.
AIHA LAP- Lab ID #100986, NY State DOH ELAP -Lab ID #11864, State of Ohio- Lab ID # 10042
APPENDIX C
QUALIFICATIONS
File details come from the government source that posted it. Updated .