SRCHP_Stokes-Masters_Combined_-_13_August_2025_DS.pdf
PDF 6 MB Posted
- Attached to
- City Hall Wind Mitigation
- Solicitation number
- 26-008
- Issued by
- Santa Rosa County, Mount Carmel CDP, Florida
About this file
This is a structural engineering design document for a residential housing reconstruction project at 8616 Baxter Road, Milton, Florida 32583, prepared by Dean A. Spencer Engineering, Inc. and sealed by Maxwell M. Spencer, PE on August 13, 2025. The document comprises comprehensive structural plans and specifications for a single-family residence located in Santa Rosa County, designed to comply with the 2023 Florida Building Code and ASCE 7-22 wind standards. The project is located in a windborne debris area with design wind speeds of 124 MPH nominal and 160 MPH ultimate, with a mean roof height of 3.1 feet and 6/12 roof slope. The structure features pre-engineered roof trusses, engineered floor systems, concrete masonry unit (CMU) foundation walls with reinforced concrete slabs-on-grade, and multiple tie-down system options for windstorm resistance. The procurement memorandum indicates a mandatory pre-bid meeting scheduled for 9:30 a.m. on Tuesday, November 18, 2025, at the project site, with bid submissions due by 10:00 a.m. on Monday, December 8, 2025, through the Santa Rosa County Procurement Portal, with public bid opening via Teams.
The structural design specifications detail comprehensive requirements for materials, connections, and construction methods, including concrete compressive strengths ranging from 3000 to 4000 PSI, engineered wood products meeting specific material properties, Simpson connector hardware with Florida product approval numbers, and detailed flashing and moisture barrier requirements per FBC 2023 Section 1405. All hardware must be hot-dipped galvanized or stainless steel, with specific provisions for stainless steel hardware in flood-prone areas. The document includes detailed foundation design notes recommending a geotechnical engineering report prior to construction based on an assumed allowable soil bearing capacity of 1500 PSF, soil compaction requirements of 95% Modified Proctor minimum, and footings set no closer than 24 inches to seasonal high groundwater levels. Contractor responsibilities encompass verification of all dimensions, flood zone designations, base flood elevation, water-proofing, weather-proofing, flashing, proper termite treatment, and compliance with all OSHA regulations. The Santa Rosa County Board of County Commissioners encourages participation from small businesses, minority-owned businesses, and disadvantaged business enterprises, with no specified contract award date or term noted in the procurement memorandum.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
August 2025
Building Inspection Department
This letter references the Residential Structure located at:
8616 Baxter Road, Milton, FL
The digital signature on this page applies only to the pages within this binder that contain the structural engineer of record (S.E.O.R.) seal as shown at the bottom of this letter. Dean A.
Spencer Engineering, Inc. is only responsible for the wind load design and structural analysis of the project. The S.E.O.R. is only responsible for the structural design specifications as shown on the sealed architectural pages.
This item has been digitally signed and sealed by Maxwell M. Spencer, PE on 8/13/2025 using a Digital Signature. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies.
Sincerely, Maxwell M. Spencer
Maxwell M. Spencer, PE – FL#88877
Dean A. Spencer Engineering, Inc.
1197 Tiger Trace Blvd
Gulf Breeze, FL 32563 850.932.8730 dean.spencer.pe@gmail.com
GEOTECHNICAL ENGINEERING AND SITE-PREP:
IT IS RECOMMENDED THAT A GEOTECHNICAL ENGINEERING REPORT BE FABRICATED PRIOR TO
CONSTRUCTION BY A LICENSED GEOTECHNICAL ENGINEER IN THE STATE OF FLORIDA.
WITHOUT A GEOTECHNICAL REPORT BEING PROVIDED, THE STRUCTURAL ENGINEER OF
RECORD AND DESIGN TEAM SHALL NOT BE HELD LIABLE FOR SOIL CONDITIONS THAT A
GEOTECHNICAL REPORT WOULD HAVE PROVIDED.
WHERE FOUNDATION IS TO BEAR ABOVE GREATER THAN 12" OF COMPACTED FILL, A
GEOTECHNICAL INVESTIGATION SHALL BE CONDUCTED PER FBC 2023 SECTION 1803.5.8.
This item has been digitally signed and sealed by Maxwell M.
Spencer, PE on 8/13/2025 using a Digital Signature. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies.
8/13/2025
R E
V
IS
IO
N
S
D A
T E
D E
S C
R
IP
T
IO
N
SHEET NUMBER:
DATE:
S H
E E
T T
IT
L
E
P R
O J E
C T
T
IT
L E
SEAL
S1
N O
T E
S /D
E T
A
IL
S
S T
R U
C T
U R
A L
FBC 2023, SECTION 1609.1.2.
2. STRAP OPENINGS PER ALL-THREAD TIE-DOWN SYSTEM DETAILS.
1. SEE WALL SECTIONS FOR ADDITIONAL REQUIREMENTS.
BUILDING CODE 2023 (8TH EDITION), SECTION 1609, AND WIND FORCES BY ASCE 7-22.
FLORIDA
SEE TIE-DOWN OPTIONS ON SHEET S4
2) RAIN LOAD: N/A
'A' ZONE: = 3.1'
ROOF SLOPE: 6/12
MEAN ROOF HEIGHT: LESS THAN 30'
EXPOSURE CATEGORY: B
124 MPH
160 MPH
25 PSF
MAXWELL M. SPENCER, PE - FL #88877
SCHEDULE ON SHEET S1.
FBC 2023 AND ASCE 7-22:
, PROTECTION OF OPENINGS.
THIS STRUCTURE IS IN A WINDBORNE DEBRIS AREA. ALL EXTERIOR GLAZING SHALL BE PROTECTED AS STATED IN THE
C) SEE PLANS FOR ALL CONNECTORS AND NAIL PATTERN REQUIREMENTS.
B) DECKING: SEE SHEATHING NOTES.
A) PRE-ENGINEERED ROOF TRUSSES, #2 SYP MINIMUM, SPACING 24" O.C. (BY TRUSS MANUFACTURER).
4) ROOF SHALL BE CONSTRUCTED AS FOLLOWS:
D) INTERIOR PARTITION WALLS: 2x4 #2 SPRUCE PINE-FIR (SPF) STUDS; SPACING 16" O.C.
C) WALL SHEATHING: SEE SHEATHING NOTES.
B) INTERIOR BEARING SHEAR WALLS: SEE WALL FRAMING SCHEDULE ON SHEET S1.
.1.
A) EXTERIOR WALLS: SEE WALL FRAMING
3) WALLS SHALL BE CONSTRUCTED AS FOLLOWS:
2) SEE DRAWINGS FOR ALL ANCHORAGE REQUIREMENTS.
1) ALL COMPONENT AND CLADDING SHALL HAVE FLORIDA PRODUCT APPROVAL NUMBERS.
GENERAL REQUIREMENTS:
1) RAIN INTENSITY, i: 4.75 IN./HOUR.
RAIN CRITERIA:
IN ALL DIRECTIONS (SEE DIAGRAM ON SHEET S1).9)
8) INTERNAL PRESSURE COEFFICIENT: (+/-) 0.18.
7) STRUCTURE IS FULLY ENCLOSED.
6)
5)
4)
3) RISK CATEGORY: II
2) NOMINAL WINDSPEED:
(3-SECOND GUST) 1) ULTIMATE WINDSPEED:
WIND CRITERIA:
PRIOR TO CONSTRUCTION IF HEAVY FINISH MATERIAL IS TO BE USED.
DEAD LOADS ASSUME STANDARD USE of FINISH MATERIALS THROUGHOUT STRUCTURE. CONTACT E.O.R. NOTE:
K) CONCRETE SELF WEIGHT: 150 PCF DEAD LOAD (DL).
J) ROOF LIVE LOAD: 20 PSF LIVE LOAD (Lr).
I) ENGINEERED ROOF TRUSS: 20 PSF DEAD LOAD (DL) - INCLUDING SELF WEIGHT.
d) 20 PSF LIVE LOAD (LL) - LIGHT STORAGE
c) 12 PSF DEAD LOAD (DL) - LIGHT STORAGE - INCLUDING SELF WEIGHT.
b) 10 PSF LIVE LOAD (LL) - NO STORAGE.
a) 9 PSF DEAD LOAD (DL) - NO STORAGE - INCLUDING SELF WEIGHT.
H) 2x CEILING JOISTS:
G) 2x RAFTERS: 13 PSF DEAD LOAD (DL) - INCLUDING SELF WEIGHT.
F) DECK LIVE LOAD: 60 PSF LIVE LOAD (LL).
E) FLOOR LIVE LOAD: 40 PSF LIVE LOAD (LL).
DEAD LOAD (DL) - INCLUDING SELF WEIGHT.D) PRE-ENGINEERED FLOOR TRUSS:
C) 2x WOOD FLOOR JOIST: 15 PSF DEAD LOAD (DL) - INCLUDING SELF WEIGHT.
B) STRUCTURAL WOOD WALLS (BRICK): 48 PSF DEAD LOAD (DL).
A) STRUCTURAL WOOD WALLS (SIDING): 15 PSF DEAD LOAD (DL).
DESIGN LOADS PER
ENGINEER OF RECORD:
WILL BE IDENTIFIED BY THE SAME REVISION NUMBER ISSUED CONSEQUENTLY.
4. REVISIONS ARE IDENTIFIED BY A REVISION NUMBER WITHIN A TRIANGLE. ALL REVISIONS ISSUED ON A SINGLE DATE
DEAN A. SPENCER ENGINEERING PRIOR TO CONSTRUCTION IF CONFLICTS EXIST.
3. THE STRUCTURAL DOCUMENTS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS. CONTACT
2. THIS STRUCTURE IS DESIGNED TO WITHSTAND ULTIMATE AND NOMINAL WINDSPEEDS AS SPECIFIED
REQUIREMENTS OF CODES AND STANDARDS.
1. TO THE BEST OF OUR KNOWLEDGE, STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH ALL APPLICABLE
GENERAL NOTES:
ACI 318-19
ACI 318-19.
13. ALL LAP SPLICES SHALL BE 48 BAR DIAMETERS UNLESS NOTES OTHERWISE.
, UNLESS NOTED OTHERWISE.12. ALL HOOKS ARE STANDARD PER
FOR CONCRETE", ASTM C 494.
11. FLY ASH OR OTHER POZZOLANS USED AS ADMIXTURES SHALL CONFORM TO "SPECIFICATION FOR CHEMICAL ADMIXTURES
CONCRETE", ASTM A 615.
10. WATER-REDUCING AND RETARDING ADMIXTURES SHALL CONFORM TO "SPECIFICATION FOR CHEMICAL ADMIXTURES FOR
ASTM A 615.
9. AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO "SPECIFICATION FOR AIR-ENTRAINING ADMIXTURES FOR CONCRETE", PLAIN BILLET-STEEL BARS FOR CONCRETE REINFORCEMENT", ASTM A 615.
8. REINFORCEMENT SHALL BE DEFORMED REINFORCEMENT AND SHALL CONFORM TO "SPECIFICATION OF DEFORMED AN
SALTS, ORGANIC MATERIALS, OR OTHER SUBSTANCES DELETERIOUS TO CONCRETE OR REINFORCEMENT.
7. WATER USED IN MIXING CONCRETE SHALL BE CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OILS, ACIDS, ALKALIS,
6. MAXIMUM NOMINAL AGGREGATE SIZE OF SLABS SHALL NOT EXCEED 1/3 OF SLAB DEPTH.
5. CONCRETE AGGREGATES SHALL CONFORM TO "SPECIFICATION FOR CONCRETE AGGREGATES", ASTM C 33.
4. CEMENT SHALL CONFORM TO "SPECIFICATIONS OF PORTLAND CEMENT", ASTM C 150.
E) BEAMS AND COLUMNS NOT EXPOSED TO WEATHER, AND NOT IN CONTACT WITH GROUND: 1.5"
D) #3-#11 REBAR WITHIN SLABS AND WALLS, NOT EXPOSED TO WEATHER, AND NOT IN CONTACT WITH GROUND: 3/4"
C) #6-#18 REBAR EXPOSED TO WEATHER, OR IN CONTACT WITH THE GROUND: 2"
B) #3-#5 REBAR EXPOSED TO WEATHER, OR IN CONTACT WITH THE GROUND: 1.5"
A) CAST PERMANENTLY AGAINST THE GROUND: 3"
3. THE FOLLOWING REBAR CLEARANCES SHALL BE MET:
2. ALL CONCRETE SHALL MEET THE FOLLOWING ULTIMATE COMPRESSIVE STRENGTHS IN 28 DAYS:
1. ALL CONCRETE WORK HAS BEEN DESIGNED TO CONFORM TO
REINFORCED CONCRETE NOTES:
14. ALL REINFORCING STEEL SHALL BE GRADE 40.
C) ELEVATED CONCRETE BEAMS AND SLABS: f'c = 4000 PSI
B) ICF WALLS, CAST-IN-PLACE COLUMNS, AND MASONRY WALLS: f'c = 3000 PSI
A) FOOTINGS AND SLABS-ON-GRADE: f'c = 3000 PSI
(ALLOWABLE STRESS DESIGN PRESSURES)
PRESSURES: (+/-) 50 PSF (D.P. 50)
ALL EXTERIOR DOOR & OPENING
FLORIDA PRODUCT APPROVAL
SIMPSON WOOD CONNECTORS
SIMPSON ABU66 (FL10860.4)
SIMPSON HUS412 (FL10655.26)
SIMPSON H2.5A (FL10456.3)
SIMPSON LUS210 (FL10655.31)
SIMPSON MSTA36 (FL10852.9)
SIMPSON SPH6 (FL10456.12)
SIMPSON SPH4 (FL10456.12)
SIMPSON MGT (FL11470.7)
SIMPSON MSTA24 (FL10852.9)
SIMPSON LSTA18 (FL10852.6)
SIMPSON LSTHD8 (FL13326.2)
SIMPSON SP4 (FL 10456.11)
SIMPSON ABU88 (FL10860.4)
SIMPSON CBU66 (FL10860.9)
SIMPSON CBU88 (FL10860.9)
SIMPSON HHUS5.5/10 (FL10531.8)
SIMPSON HGT-2 (FL10456.4)
SIMPSON HUC212-3 (FL10655.18)
SIMPSON HUC612 (FL10655.22)
SIMPSON SP6 (FL 10456.11)
CAPACITIES ARE REDUCED BY APPROXIMATELY 18% WHERE VERTICAL HOLES ARE INSTALLED.
'WANDERING' AS IT PASSES THROUGH KNOTS. HOLE SHALL BE CENTERED WITHIN THE BEAM WIDTH. ALLOWABLE
9. VERTICAL HOLES SHALL BE INSTALLED PER THE DESIGN DRAWINGS. DRILL GUIDES SHALL BE USED TO MINIMIZE
MAY ONLY BE LOCATED WITHIN THE MIDDLE THIRD OF THE MEMBER SPAN. HOLES MAY NOT EXCEED 2" IN DIAMETER.
8. HOLES BORED THROUGH JOISTS SHALL ONLY BE LOCATED WITHIN THE MIDDLE THIRD OF THE MEMBER DEPTH. HOLES
7. NOTCHES ON THE BOTTOM ENDS OF MEMBERS SHALL NOT EXCEED ONE TENTH THE MEMBER DEPTH.
DESIGN MATERIAL: VERSA-LAM COLUMN 1.8E-2750 (PSL SIMILAR).
Fcy (PERP.) = 750 PSI // E = 1.8x10^6 PSI // Emin = 9.3x10^5 PSI
Fb = 2500 PSI // Ft = 1270 PSI \\ Fv = 190 PSI // Fc (PARALLEL) = 3000 PSI // Fcz (PERP.) = 450 PSI
6. VERSALAM COLUMNS SHALL HAVE THE MINIMUM MATERIAL PROPERTIES AS FOLLOWS:
DESIGN MATERIAL: 24F-V8 - 24F-1.8E - SOUTHERN PINE 24F-V5M1 (PRESSURE TREATED)
Fb = 2400 PSI // Fv = 300 PSI // Fc (PARALLEL) = 1650 PSI // Fc (PERP.) = 740 PSI // E = 1.8x10^6 PSI
5. GLULAM BEAMS (PRESSURE TREATED) SHALL HAVE THE MINIMUM MATERIAL PROPERTIES AS FOLLOWS:
4. LVL BEAMS MAY BE TRIMMED TO SIZE WITHOUT TAKING A REDUCTION IN THE ALLOWABLE MATERIAL PROPERTIES.
Fb = 2900 PSI // Fv = 285 PSI // Fc (PARALLEL) = 3200 PSI // Fc (PERP.) = 750 PSI // E = 2x10^6 PSI
3. LVL BEAMS SHALL HAVE THE MINIMUM MATERIAL PROPERTIES AS FOLLOWS:
2. DO NOT STORE ENGINEERED WOOD PRODUCTS IN CONTACT WITH GROUND. STACK MEMBERS FLATWISE.
MANUFACTURER AND SHALL MEET APA SPECIFICATIONS.
1. LVL BEAMS, GLULAM BEAMS, AND VERSALAM AND PSL COLUMNS SHALL BE MANUFACTURED BY AN APA MEMBER
ENGINEERED WOOD PRODUCTS:
TMS 402/602-16, ACI 530/530.1-16, AND ASCE 5/6-16.
6. ALL REINFORCING STEEL SHALL BE GRADE 40.
14. LINTEL BEAMS SHALL BE FORMED WITH SOLID BOTTOM LINTEL BLOCKS OR KNOCK-OUT BOND BEAM BLOCKS.
13. PROVIDE (2) VERTICAL DOWELS EACH SIDE OF OPENINGS AND EXTEND TO TOP COURSE.
DISCONTINUOUS ENDS A MINIMUM OF 12".
HEIGHT. CORNERS SHALL USE PREFABRICATED CORNERS AND TEES AT WALL INTERSECTIONS. OVERLAP
COURSE FOR ALL CMU WALLS ABOVE GRADE AND ALL CMU FOUNDATION WALLS EXCEEDING 4 BLOCK IN
12. STANDARD (9-GAGE) LADDER TYPE HORIZONTAL JOINT REINFORCEMENT SHALL BE INSTALLED EVERY OTHER
E) ALL SPLICES SHALL BE 48 BAR DIAMETERS UNLESS SPECIFIED OTHERWISE.
D) GROUT STOP IS A FIBERGLASS MESH CONFORMING TO ASTM D1668-73, TYPE 207.
C) HORIZONTAL REINFORCING AS NOTED IN NOTE 12 IN ADDITION TO SPECIFIED BOND BEAMS AND LINTELS.
B) PROVIDE THREE FILLED CELLS OF TYPICAL REINFORCING AT CORNERS.
A) PROVIDE FOUR FILLED CELLS OF TYPICAL REINFORCING AT INTERSECTIONS.
11. SEE DETAILS FOR TYPICAL WALL REINFORCING REQUIREMENTS WITH ADDITIONAL REQUIREMENTS BELOW:
10. ALL CONCRETE MASONRY UNITS SHALL BE PLACED IN RUNNING BOND.
HOOKS WITH A MINIMUM 8" LEG.
9. DOWEL ALL CMU REINFORCING IN FOOTING AND EXTEND INTO UPPERMOST BOND BEAM WITH 90 DEGREE
8. ALL HORIZONTAL REINFORCEMENT SHALL MAINTAIN 2-3/8" CLEAR OR GREATER.
7. ALL VERTICAL REINFORCEMENT SHALL BE CENTERED WITHIN THE CMU CELLS UNLESS NOTED OTHERWISE.
A) MINIMUM COMPRESSIVE STRENGTH (f'g/f'c) = 3000 PSI.
5. GROUT SHALL MEET SPECIFICATIONS OF ASTM C 476.
D) ALLOW 24 HOURS MINIMUM CURE TIME PRIOR TO GROUT INSTALLATION.
C) MORTAR SHALL BE IN ACCORDANCE WITH ASTM C 270.
B) EXTERIOR, AT OR BELOW GRADE: TYPE S.
A) EXTERIOR, ABOVE GRADE: TYPE N.
4. MORTAR SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS:
3. MASONRY BLOCK COMPRESSIVE STRENGTH: f'm = 2000 PSI **
2. CMU UNITS SHALL CONFORM TO ASTM C 90.
1. ALL MASONRY WORK TO CONFORM TO
CONCRETE MASONRY (CMU):
NAILED WITH 8d COMMON RINGSHANK NAILS; SPACING 4" EDGE AND 8" FIELD.
8. ALL COVERED PORCHES SHALL BE DECKED UNDERNEATH WITH 7/16" OSB OR 15/32" 4-PLY APA RATED PLYWOOD AND
7. ALL BRACING OF THE TRUSSES SHALL BE #2 SOUTHERN YELLOW PINE (SYP) OR BETTER.
6. HOLES AND NOTCHES MAY NOT BE INSTALLED INTO ENGINEERED TRUSSES UNLESS SPECIFIED BY DESIGN ENGINEER.
SPECIFIED OTHERWISE.
5. ALL FLOOR SYSTEMS SHALL BE DESIGNED TO MEET AN ALLOWABLE DEFLECTION CRITERIA OF L/480 AND (D+L)/360, UNLESS
GENERAL NOTES.
4. TRUSSES SHALL BE DESIGNED FOR THE DEAD LOAD OF THE TRUSSES AND BRACING, AS WELL AS THE LOADS SPECIFIED IN
DRAWINGS. ARRANGEMENT OF WEB MEMBERS SHALL BE AT THE DISCRETION OF THE TRUSS ENGINEER.
3. TOP AND BOTTOM CHORDS SHALL BE PROVIDED WITH THE SHAPES AND CONFIGURATIONS INDICATED ON THE DESIGN
2. DESIGN OF TRUSS SYSTEM SHALL BE IN ACCORDANCE WITH
NECESSARY COMPONENTS OF THE TRUSS SYSTEM.
STATE WHERE THE PROJECT IS LOCATED. TRUSS ENGINEER SHALL PROVIDE SEALED SHOP DRAWINGS OF ALL
1. WOOD TRUSSES, CONNECTIONS, AND BRACING SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE
PRE-ENGINEERED WOOD TRUSSES:
9. SOFFITS SHALL BE CONSTRUCTED PER FBC 2023, SECTION 1410.
CONNECTED WOOD TRUSS CONSTRUCTION.
TPI-1-2014 - NATIONAL DESIGN STANDARD FOR METAL PLATE
Dean A.
Spencer
Engineering, Inc.
#9070
Authorization
#44472
#88877
850.932.8730 (Voice)
GULF BREEZE, FL 32563
1197 TIGER TRACE BLVD
DEAN A. SPENCER ENGINEERING, INC.
dean.spencer.pe@gmail.com
AL #40501
FL #88877
MAXWELL M. SPENCER, PE
AL #29262, CA #3467
FL #44472, CA #9070
SECB (2006 TO MAR 2022)
DEAN A. SPENCER, PE
CHECKED BY: MMS
DRAWN BY: MMS
BRACING OF STRUCTURE.
10. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND PERFORMANCE OF ALL SHORING AND
9. CONTRACTOR IS RESPONSIBLE WITH COMPLYING WITH ALL OSHA REGULATIONS.
OF CONSTRUCTION.
8. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES
7. CONTRACTOR IS RESPONSIBLE FOR PROPER TERMITE TREATMENT OF SITE AND STRUCTURE.
6. CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL HARDWARE IS INSTALLED PER INDUSTRY STANDARDS.
5. CONTRACTOR SHALL VERIFY ALL ASSUMPTIONS AS SPECIFIED ON THESE DESIGN DRAWINGS.
4. CONTRACTOR SHALL CONTACT ENGINEER OF RECORD FOR ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
COORDINATE WITH A LICENSED ARCHITECTURAL FIRM FOR SPECIFICATIONS IF/AS REQUIRED.
3. CONTRACTOR IS RESPONSIBLE FOR ALL WATER-PROOFING, WEATHER-PROOFING AND FLASHING OF STRUCTURE.
ELEVATION REQUIREMENTS.
2. CONTRACTOR IS RESPONSIBLE FOR VERIFYING FLOOD ZONE, BASE FLOOD ELEVATION, AND DESIGN FLOOR
1. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS ON SITE AND DESIGN DRAWINGS..
CONTRACTORS RESPONSIBILITIES:
5) WALLS EXCEEDING 10'-1" IN HEIGHT SHALL BE BLOCKED AT MIDSPAN MINIMUM.
4) *PANEL-WIDTH - WALL WIDTH BETWEEN OPENING AND CORNER AND WALL WIDTH BETWEEN OPENINGS.
3) 10'-1" WALLS: PANEL-WIDTH 5'-0" AND LESS SHALL BE BLOCKED AT MIDSPAN.
2) 9'-1" WALLS: PANEL-WIDTH 4'-6" AND LESS SHALL BE BLOCKED AT MIDSPAN.
1) 8'-1" WALLS: PANEL-WIDTH 4'-0" AND LESS SHALL BE BLOCKED AT MIDSPAN.
A) SHEATHING SHALL BE NAILED TO ROOF MEMBERS WITH 8d COMMON RINGSHANK NAILS (0.131" x 2-1/2");
ROOF SHEATHING:
PANEL EDGES AND NAILS AT ALL PANEL EDGES SHALL BE STAGGERED.
THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS SHALL BE 3" NOMINAL OR GREATER AT ADJOINING
JOINTS SHALL BE OFFSET EACH SIDE OF WALL TO FALL ON DIFFERENT FRAMING MEMBERS. ALTERNATIVELY, D) WHERE SPECIFIED, SHEATHING SHALL BE INSTALLED ON BOTH SIDES OF WALL PANELS. SHEATHING PANEL
B) 2x BLOCKING SHALL BE ADDED AT ALL PANEL JOINTS. ADDITIONAL BLOCKING SHALL BE ADDED PER NOTE (C).
, UNLESS NOTED OTHERWISE ON THE DESIGN DRAWINGS.(0.113" x 2-1/2");
A) SHEATHING SHALL BE NAILED TO WALL STUDS WITH 8d COMMON NAILS (0.131" x 2-1/2") OR 8d BOX NAILS
. WALL SHEATHING:
WALL AND ROOF SHEATHING:
SPACING 3" EDGE AND
5/8" OSB (SPAN RATING 40/20) OR 19/32" (SPAN RATING 40/20) 4-PLY APA RATED PLYWOOD.
THE SPECIFIED WIDTH BELOW. SHEATHING SHALL BE NAILED TO BLOCKING PER TYP. SPECIFICATIONS.
C) WHERE FULL HEIGHT SHEATHING IS USED, BLOCKING SHALL BE INSTALLED WHEN *PANEL-WIDTH IS LESS THAN
SPACING 3" EDGE AND 8" FIELD
7/16" OSB (SPAN RATING 24/16) OR 15/32" (SPAN RATING 32/16) 4-PLY APA RATED PLYWOOD
6" FIELD.
S a n ta R o s a C o u n ty
M il to n F lo ri d a
B a x te r
R o a d
R e s id e n c e
4. MINIMUM SLAB COMPRESSIVE STRENGTH: 3000 PSI.
RECOMMENDED #3 REBAR; SPACING 36" O.C. EACH DIRECTION
6. IF GIVEN, MONOLITHIC FOOTING OPTION MAY ONLY BE USED IF F.F.E. DOES NOT EXCEED 12" ABOVE GRADE.
THESE MAY BE USED REGARDLESS OF THE EXTERIOR FOUNDATION CONSTRUCTION TYPE.
5. GRADE BEAM FOOTINGS AND MONOLITHIC STEP-DOWN FOOTINGS SHALL BE FORMED AND POURED WITH THE SLAB.
3. 6 MIL. POLYETHYLENE SHEETING SHALL BE INSTALLED BETWEEN SOIL AND CONCRETE, UNLESS NOTED OTHERWISE.
2. REINFORCEMENT SHALL BE SUPPORTED ON APPROVED PC3 CHAIRS.
C) FIBERMESH (0.75 - 3 LBS / CUBIC YARD OF CONCRETE).
B) W1.4xW1.4 / 6x6 WWF
.A)
1. 4" SLABS SHALL BE REINFORCED WITH ONE OF THE FOLLOWING:
SLABS-ON-GRADE:
NOT TO SCALE
FLASHING DETAIL
FBC 2023 EXAMPLE
INSTALLATION
UP FOR WINDOW/DOOR
CUT HOUSEWRAP AND FOLD
OTHER 3 SIDES
INTO OPENING ON
FOLD HOUSE WRAP
OVER HOUSEWRAP
FLASHING MATERIAL
INSTALL APPROVED
PERIMETER TO WALL
APPROVED SEALANT AROUND
INSTALL WINDOW/DOOR W/
TOP OVER WINDOW/DOOR FLANGES
APPLY APPROVED FLASHING ON SIDES &
25 GRADE NS OR GREATER
AAMA 800 OR ASTM C920 CLASS
SEALANT SHALL COMPLY W/
FMA/AAMA 200, FMA/WDMA 250, OR FMA/AAMA/WDMA 300.
FLASHING SHALL BE INSTALLED PER FMA/AAMA 100,
INSTALLATION & FLASHING INSTRUCTIONS
OPTION: INSTALL PER FENESTRATION MANUFACTURER'S
1405.4.2 MASONRY.
1405.4.1 EXTERIOR WALL POCKETS.
1405.4 FLASHING:
FLORIDA BUILDING CODE 2023:
DESIGNED IN ACCORDANCE WITH SECTION 1405.6.
STRUCTURAL FLOORS, SHELF ANGLES AND LINTELS WHERE ANCHORED VENEERS ARE
POINTS OF SUPPORT, INCLUDING ABOVE THE FOUNDATION WALL OR SLAB, AND OTHER
GROUND LEVEL LOCATED IN THE FIRST COURSE OF MASONRY ABOVE FINISHED
SHALL BE FLASHING AND WEEP HOLES IN ANCHORED VENEER
DAMAGE.BE PROVIDED TO PREVENT WATER
AVOIDED OR PROTECTED WITH CAPS OR DRIPS, OR OTHER APPROVED MEANS SHALL
WALL POCKETS OR CREVICES IN WHICH MOISTURE CANACCUMULATE SHALL BE
IN EXTERIOR WALLS OF BUILDINGS OR STRUCTURES,
PROJECTING TRIM.
SIDES AND THE ENDS OF COPINGS, UNDER SILLS AND CONTINUOUSLY ABOVE
WALL. FLASHING WITH PROJECTING FLANGES SHALL BE INSTALLED ON BOTH
BUILT-IN GUTTERS AND SIMILAR LOCATIONS WHERE MOISTURE COULD ENTER THE
CHIMNEYS, PORCHES, DECKS, BALCONIES AND SIMILAR PROJECTIONS AND AT
EXTERIOR WALL ASSEMBLIES, EXTERIOR WALL INTERSECTIONS WITH ROOFS,
DOOR AND WINDOW ASSEMBLIES, PENETRATIONS AND TERMINATIONS OF
EXTERIOR. FLASHING SHALL BE INSTALLED AT THE PERIMETERS OF EXTERIOR
PREVENT MOISTURE FROM ENTERING THE WALL OR TO REDIRECT IT TO THE
FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO
SPECIFICATION SHEET PRIOR TO CONSTRUCTION.
NUMBERS OF THE BUILDING COMPONENTS WITH A PRODUCT APPROVAL
CODE, THE CONTRACTOR SHALL PROVIDE THE INFORMATION AND APPROVAL
AS REQUIRED BY FLORIDA STATUTE 553.842 AND THE FLORIDA ADMINISTRATIVE
STRUCTURAL DESIGN OF THIS PROJECT.
2023 FBC SECTION 107.2.4. THE ENGINEER IS ONLY RESPONSIBLE FOR THE
RESISTIVE BARRIER, AND DETAILS AROUND OPENINGS, IN ACCORDANCE WITH
INTERSECTIONS AT ROOF, EAVES, OR PARAPETS, MEANS OF DRAINAGE, WATER-
DISSIMILAR MATERIALS, CORNERS, END DETAILS, CONTROL JOINTS,
ENVELOPE AS REQUIRED, INCLUDING FLASHING, INTERSECTIONS WITH
OWNER, OR CONTRACTOR TO PROVIDE DETAILS OF THE EXTERIOR WALL
IT SHALL BE THE RESPONSIBILITY OF THE PROJECT DESIGNER, ARCHITECT,
FLASHING MATERIAL
FOLD HOUSEWRAP OVER TOP
SDPWS 2021, SECTION 4.3.6.4.3.
b) 2"x2"x1/4" WASHERS MAY REPLACE 3"x3"x1/4" WASHERS WHERE 3" DO NOT FIT WITHIN 2x4 WALL SYSTEMS.
SIMPSON "ET-3G" EPOXY
KING STUDS MAY BE REPLACED WITH SIMPSON SDWC15600 SCREWS ON THE NARROW FACE OF THE STUD.
SCREWS INSTALLED ON THE WIDE FACE OF THE STUDS. SIMPSON SPH# STRAPS SPECIFIED TO BE INSTALLED AT INTERMEDIATE
12. SIMPSON SPH# STRAPS SPECIFIED TO BE INSTALLED AT EXTERIOR KING STUDS MAY BE REPLACED WITH (2) SIMPSON SDWC15600
FRAMING MEMBER HURRICANE CLIP.
SPACING 16" O.C. (EACH STUD). SCREWS SHALL BE INSTALLED ON THE WALL FACE MATCHING THE INSTALLATION OF THE
11. SIMPSON SPH# STRAPS WHEN SPECIFIED TO BE SPACED AT 32" O.C. MAY BE REPLACED WITH SIMPSON SDWC15600 SCREWS;
c) 5/8" x 10" SIMPSON STRONG-BOLT 2 WEDGE ANCHOR.
b) 5/8" x 8" SIMPSON TITEN HD ANCHOR (EXCEPT WHERE ALL-THREAD ROD IS REQUIRED TO BE COUPLED ABOVE).
OR EQUIVALENTa) 5/8" ALL-THREAD DRILLED 7" INTO FOUNDATION USING
10. ALL POST-INSTALLED ANCHORS SHALL BE ONE OF THE FOLLOWING:
9. ALL COUPLING NUTS SHALL MEET ASTM A563 GRADE A SPECIFICATION REQUIREMENTS OR BETTER.
8. ALL WASHERS WITHIN HORIZONTAL CONNECTIONS SHALL BE 2"x2"x1/4" OR 2" DIA.x1/4".
a) NUT AND WASHERS SHALL BE REPLACED WITH SIMPSON TAKE-UP DEVICES WHERE SPECIFIED.
7. ALL WASHERS WITHIN WALL SYSTEMS SHALL BE 3"x3"x1/4" PER
6. THREADED RODS SHALL MEET ASTM A307 GRADE A SPECIFICATION REQUIREMENTS OR BETTER.
5. BOLTS SHALL MEET ASTM A307 SPECIFICATION REQUIREMENTS UNLESS NOTED OTHERWISE.
b) TYPE 316 STAINLESS STEEL SHALL BE USED FOR ALL HARDWARE SET BELOW DESIGN FLOOD ELEVATION.
a) STAINLESS STEEL SHALL NOT BE IN DIRECT CONTACT WITH DISSIMLAR STEEL MATERIALS.
4. STAINLESS STEEL HARDWARE SHALL MEET TYPE 304 OR 316 SPECIFICATION REQUIREMENTS.
3. ALL HARDWARE AND NAILS SHALL BE HOT-DIPPED GALVANIZED OR STAINLESS STEEL WHEN EXPOSED TO THE ELEMENTS.
2. ALL HARDWARE SHALL BE INSTALLED PER ALL MANUFACTURERS SPECIFICATIONS.
1. ALL NAILS SHALL BE COMMON UNLESS SPECIFIED OTHERWISE.
HARDWARE REQUIREMENTS:
5 5
COMPONENTS AND CLADDING WALLS
ANGLE
M E
A N
R O
O F
H E
IG
H
T a a a a a = 3.1' IN ALL INSTANCES
B
/ 12
LESS THAN 30 FT
160 MPH
kd = 0.85; Internal Pressure Coefficient = +/- 0.18.
EXPOSURE CATEGORY:
ROOF SLOPE: 6
MEAN ROOF HEIGHT:
(3-SEC GUST)WIND SPEED:
WHERE OFFSET WALL 'X' > 'a', ZONE 5 SHALL BE APPLIED TO CORNER
HIP - 7-45 DEG
PLAN VIEW
a a
ANGLE
M E
A N
R O
O F
H E
IG
H
T
HORIZ. BLDG. DIMENSION
ELEVATION VIEW
a a a a
11 2 2
COMPONENTS & CLADDING - ASCE 7-22
MULTIPLY TABLES BY 0.6 TO ACHIEVE ASD PRESSURES.
COMPONENTS & CLADDING WIND LOADS: PSF
AND SEISMIC STANDARDS (SDPWS 2021).
SPECIAL DESIGN PROVISIONS FOR WIND
THE NDS 2018 DESIGN MANUALS
14. ALL INTERIOR BEARING WALLS SUPPORTING FLOOR LOADING SHALL BE BLOCKED AT MIDSPAN MINIMUM.
CAPACITIES ARE REDUCED BY APPROXIMATELY 17% WHERE VERTICAL HOLES ARE INSTALLED.
'WANDERING' AS IT PASSES THROUGH KNOTS. HOLE SHALL BE CENTERED WITHIN THE BEAM WIDTH. ALLOWABLE
13. VERTICAL HOLES SHALL BE INSTALLED PER THE DESIGN DRAWINGS. DRILL GUIDES SHALL BE USED TO MINIMIZE
12. ONLY ONE MEMBER OF PLY-BUILT BEAMS MAY BE SPLICED PER SPAN. SPLICES SHALL OCCUR AT 1/4 SPANS.
NOTE: VARIOUS CONNECTORS MAY BE USED AT CONTRACTORS DISCRETION.
k. 4-PLY LVL (UP TO 24" DEPTH): (3) 1/4" x 6" SIMPSON SDS SCREWS BOTH SIDES; SPACING 6" O.C.
j. 4-PLY LVL (UP TO 14" DEPTH): (3) 1/4" x 6" SIMPSON SDS SCREWS BOTH SIDES; SPACING 12" O.C.
i. 3-PLY LVL (UP TO 24" DEPTH): (3) 1/4" x 4-1/2" SIMPSON SDS SCREWS BOTH SIDES; SPACING 6" O.C.
h. 3-PLY LVL (UP TO 16" DEPTH): (3) 1/4" x 4-1/2" SIMPSON SDS SCREWS BOTH SIDES; SPACING 12" O.C.
g. 3-PLY LVL (UP TO 12" DEPTH): (2) 1/4" x 4-1/2" SIMPSON SDS SCREWS BOTH SIDES; SPACING 16" O.C.
f. 2-PLY LVL (UP TO 24" DEPTH): (3) 1/4" x 3-1/2" SIMPSON SDS SCREWS LOADED SIDE; SPACING 12" O.C.
e. 2-PLY LVL (UP TO 12" DEPTH): (2) 1/4" x 3-1/2" SIMPSON SDS SCREWS LOADED SIDE; SPACING 16" O.C.
d. (3) 2x: 12d COMMON NAILS (0.148" x 3-1/4") EACH SIDE TOP AND BOTTOM; SPACING 5" O.C.
c. (2) 2x: 10d COMMON NAILS (0.148" x 3") EACH SIDE TOP AND BOTTOM; SPACING 6" O.C.
b. PROVIDE MINIMUM 3" CLEAR BETWEEN CONNECTORS.
a. PROVIDE 2" CLEAR TOP AND BOTTOM AND STAGGER 1/2" BETWEEN HEIGHT AND SIDES.
11. ALL PLY-BUILT BEAMS SHALL BE JOINED PER MANUFACTURER'S SPECIFICATIONS, OR AS FOLLOWS:
MEANS. BLOCKING SHALL NOT BE LESS THAN 2" IN THICKNESS AND THE FULL DEPTH OF THE JOIST.
THE ENDS OF A JOIST ARE NAILED TO A HEADER, BAND, OR RIM JOIST OR TO AN ADJOINING STUD OR BY OTHER
10. JOISTS SHALL BE SUPPORTED LATERALLY AT THE ENDS AND AT EACH SUPPORT BY SOLID BLOCKING EXCEPT WHERE
EXCEED ONE THIRD OF THE JOIST DEPTH.
9. HOLES BORED THROUGH JOISTS SHALL NOT BE WITHIN 2" OF THE BOTTOM AND TOP OF THE JOIST. HOLES SHALL NOT
WITHIN THE MIDDLE THIRD OF THE JOIST SPAN.
8. NOTCHES ON THE END OF JOISTS SHALL NOT EXCEED ONE FOURTH THE JOIST DEPTH. NOTCHING MAY NOT OCCUR
#2 SOUTHERN YELLOW PINE (SYP) MAY REPLACE #2 SPRUCE PINE-FIR (SPF) WITHIN THE WALL SYSTEMS.
7. STUDS SHALL BE FRAMED WITH #2 SPRUCE PINE-FIR (SPF), UNLESS SPECIFIED AS SOUTHERN YELLOW PINE MATERIAL.
OTHERWISE.
6. ALL EXTERIOR POSTS SHALL BE #2 SOUTHERN YELLOW PINE (SYP) OR BETTER, PRESSURE TREATED, UNLESS NOTED
- **NOTE: WALL PLATES MAY BE THE SAME MATERIAL OF THE WALL FRAMING SPECIFICATIONS.
5. ALL HORIZONTAL WOOD FRAMING MEMBERS SHALL BE #2 SOUTHERN YELLOW PINE (SYP), OR BETTER.
4. DO NOT PAINT PRESSURE TREATED WOOD MATERIALS WHEN MOISTURE CONTENT IS ABOVE 19%.
ETC.) SHALL BE PRESSURE TREATED.
3. ALL WOOD MATERIALS IN CONTACT WITH CONCRETE, CMU BLOCK, OR IS EXPOSED TO ELEMENTS (WATER, SUNLIGHT,
2. ALL WOOD DIAPHRAGMS AND WOOD SHEAR WALLS ARE DESIGNED PER THE
1. ALL SAWN LUMBER HAS BEEN DESIGNED USING THE SPECIFIED MATERIAL STRESSES AND PROPERTIES AS SHOWN IN
WOOD FRAMING:
IN THE STATE OF FLORIDA
ASSUMED ALLOWABLE SOIL BEARING CAPACITY OF 1500 PSF
2023 TABLE 1806.2 - PRESUMPTIVE LOAD BEARING VALUES.
FBC
FBC 2023 SECTION 1803.5.8
GROUNDWATER (SHGW) LEVEL.
8. BOTTOM OF EACH FOOTING SHALL BE SET NO CLOSER THAN 24" TO NORMAL PERMANENT SEASONAL HIGH
TESTING LABORATORY.
7. ALL SOILS COMPACTION SHALL BE FIELD CONTROLLED BY A LICENSED GEOTECHNICAL ENGINEER OR
6. ALL SOILS SHALL BE COMPACTED BENEATH FOOTINGS TO 95% MODIFIED PROCTOR MINIMUM.
.INVESTIGATION SHALL BE CONDUCTED PER
5. WHERE FOUNDATION IS TO BEAR ABOVE GREATER THAN 12" OF COMPACTED FILL, A GEOTECHNICAL
BE HELD LIABLE FOR SOIL CONDITIONS THAT A GEOTECHNICAL REPORT WOULD HAVE PROVIDED.
4. WITHOUT A GEOTECHNICAL REPORT BEING PROVIDED, THE STRUCTURAL ENGINEER OF RECORD SHALL NOT
.CONSTRUCTION BY A LICENSED GEOTECHNICAL ENGINEER
3. IT IS RECOMMENDED THAT A GEOTECHNICAL ENGINEERING REPORT BE FABRICATED PRIOR TO
2. REPORT ANY UNUSUAL FIELD CONDITIONS TO ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
PER 1. FOUNDATION DESIGN IS BASED ON AN
SHALLOW FOUNDATIONS:
SIMPSON BPRTUD3-4B AND SIMPSON RTUD4B
1/2" DIAMETER
NUT WHERE NO OPTION IS SHOWN.
OF SPECIFIED 3"x3"x1/4" WASHER AND NUT. IF APPLICABLE, TAKE-UP DEVICES SHALL REPLACE TYPICAL WASHER AND
TAKE-UP DEVICES IN LIEU WHERE LABELED, IT IS RECOMMENDED TO UTILIZE
WHEN ATTACHING TO 5/8" ANCHOR BOLTS.
UNLESS NOTED OTHERWISE. PROVIDE REDUCING COUPLING NUT ALL-THREAD ROD HOLDDOWNS SHALL BE
WALL PLATES AND BLOCKING SHALL MATCH THE MATERIAL SPECIFICATIONS OF THE WALL STUDS.
IF APPLICALE WHERE SPECIFIED, #2 SOUTHERN YELLOW PINE (SYP) SHALL BE USED.
WALL FRAMING STUDS, PLATES, AND BLOCKING SHALL BE #2 SPRUCE PINE-FIR (SPF) OR BETTER.
5) INTERIOR BEARING WALLS SHALL BE BLOCKED AT MID-HEIGHT MINIMUM.
4) FULLY SHEATHED WALLS SHALL BE BLOCKED PER THE WALL AND ROOF SHEATHING NOTES.
3) WALL STUDS EXCEEDING 10'-1" SHALL BE FRAMED PER THE SPECIFICATIONS ON THE STRUCTURAL FLOOR PLANS.
2x4 STUDS; SPACING 12" O.C.OR2) BETWEEN 9'-1" AND 10'-1" PLATE HEIGHTS: 2x6 STUDS; SPACING 16" O.C.
1) UP TO 9'-1" PLATE HEIGHT: 2x4 STUDS; SPACING 16" O.C.
UNLESS NOTED OTHERWISE, ALL STRUCTURAL WALLS SHALL BE CONSTRUCTED PER THIS SCHEDULE:
WOOD WALL FRAMING SCHEDULE:
WALL
ZONE
AREA (SQ. FT)
EFFECTIVE WIND
-86.835.8 -86.835.8 -63.335.8
SPEED 160 MPH
BASIC WIND
OVERHANG
-141.8 -141.8 -118.2
HIP ROOF > 20-27 DEG.
-60.745.3 -49.145.3
This item has been digitally signed and sealed by Maxwell M.
Spencer, PE on 8/13/2025 using a Digital Signature. Printed
R E
V
IS
IO
N
S
D A
T E
D E
S C
R
IP
T
IO
N
SHEET NUMBER:
DATE:
S H
E E
T T
IT
L
E
P R
O J E
C T
T
IT
L E
S2
N O
T E
S /D
E T
A
IL
S
S T
R U
C T
U R
A L
Dean A.
Spencer
Engineering, Inc.
#9070
Authorization
#44472
#88877
CHECKED BY: MMS
DRAWN BY: MMS
SEAL
B
S2 S2
NOT TO SCALE
(1-6 BLOCK HIGH)
STEP DOWN FOOTING DETAIL
MINIMUM 16" BELOW GRADE
BOTTOM OF FOOTING SHALL BE
ACI STD HOOK (12 BAR DIAMETERS)
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
PER SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB
#4 AT 48" O.C. AND EVERY CORNER.
VERTICAL REINFORCEMENT:
12" INTO SLAB
#4 CONTINUOUS AT BOND BEAM
EXCEEDS 4 COURSES IN HEIGHT.
OTHER COURSE WHEN BLOCK HEIGHT
REINFORCEMENT SHALL BE INSTALLED EVERY
HEAVY DUTY LADDER OR TRUSS
STEPDOWN PER ARCHITECTURAL
EXPANSION JOINT
A
S2 S2
NOT TO SCALE
(1-6 BLOCK HIGH)
EXTERIOR FOOTING DETAIL
MINIMUM 16" BELOW GRADE
BOTTOM OF FOOTING SHALL BE
ACI STD HOOK (12 BAR DIAMETERS)
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB PER
SLOPE GRADE AWAY FROM STRUCTURE
12" INTO SLAB
#4 CONTINUOUS AT BOND BEAM
GREATER THAN 4 COURSES.
OTHER COURSE WHEN BLOCK HEIGHT IS
REINFORCEMENT SHALL BE INSTALLED EVERY
HEAVY DUTY LADDER OR TRUSS
2x WALL FRAMING PER PLANS
2x WALL FRAMING PER PLANS
16" INTO SLAB
(2) #4 CONTINUOUS REBAR
AND LOCATION REQUIREMENTS
P.T. POST; SEE PLANS FOR SIZING
C
S2 S2
NOT TO SCALE
(1-6 BLOCK HIGH)
PORCH FOOTING DETAIL
ACI STD HOOK (12 BAR DIAMETERS)
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
PER SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB
SLOPE GRADE AWAY FROM STRUCTURE
EXCEEDS 4 COURSES IN HEIGHT.
OTHER COURSE WHEN BLOCK HEIGHT
REINFORCEMENT SHALL BE INSTALLED EVERY
HEAVY DUTY LADDER OR TRUSS
4"
-1
FLUSH EDGE FOR SIMPSON STHD## STRAP
3" CLEAR FOR SIMPSON CB## POST BASE
2" CLEAR FOR SIMPSON ABU##Z POST BASE
SIMPSON STHD## - TURNDOWN NOT REQUIRED
SIMPSON CB## - 14" WIDE x 11" DEEP
SIMPSON ABU##Z - 14" WIDE x 8" DEEP
MONOLITHIC TURNDOWN TO REPLACE TOP COURSE:
CELLS FILLED WITH 3000 PSI CONCRETE.
8" REINFORCED CMU STEMWALL WITH ALL
CELLS FILLED WITH 3000 PSI CONCRETE.
8" REINFORCED CMU STEMWALL WITH ALL
#4 AT 48" O.C. AND EVERY CORNER.
VERTICAL REINFORCEMENT:
CELLS FILLED WITH 3000 PSI CONCRETE.
8" REINFORCED CMU STEMWALL WITH ALL
21"
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
21"
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
21"
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
P.T. 2x #2 S.Y.P. SILL PLATE
CORNER AND OPENING AND 3"x3"x1/4" WASHER AND NUT
WITH 5/8"x12" J-BOLT; SPACING 48" O.C. AND WITHIN 8" OF EACH
P.T. 2x #2 S.Y.P. SILL PLATE
CORNER AND OPENING AND 3"x3"x1/4" WASHER AND NUT
WITH 5/8"x12" J-BOLT; SPACING 48" O.C. AND WITHIN 8" OF EACH
MINIMUM 16" BELOW GRADE
BOTTOM OF FOOTING SHALL BE
AND #4 AT 48" O.C. BETWEEN
EACH CELL UNDER POST, EVERY CORNER
VERTICAL REINFORCEMENT:
P.T. 2x #2 S.Y.P. SILL PLATE
CORNER AND OPENING AND 3"x3"x1/4" WASHER AND NUT
WITH 5/8"x12" J-BOLT; SPACING 48" O.C. AND WITHIN 8" OF EACH
2x WALL FRAMING PER PLANS
PER SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
14"
-1
MINIMUM 12" BELOW GRADE
BOTTOM OF FOOTING SHALL BE
FROM STRUCTURE
SLOPE GRADE AWAY
A
S2 S2
NOT TO SCALE
FOOTING DETAIL
EXTERIOR MONOLITHIC
AND LOCATION REQUIREMENTS
P.T. POST; SEE PLANS FOR SIZING
FLUSH EDGE FOR SIMPSON STHD## STRAP
3" CLEAR FOR SIMPSON CB## POST BASE
2" CLEAR FOR SIMPSON ABU##Z POST BASE
STHD## EMBED STRAP IS USED
#4 CONT. REBAR REQUIRED IF SIMPSON
-1
14"
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
PER SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB
MINIMUM 12" BELOW GRADE
BOTTOM OF FOOTING SHALL BE
FROM STRUCTURE
SLOPE GRADE AWAY
C
S2 S2
NOT TO SCALE
FOOTING DETAIL
PORCH MONOLITHIC
16"
P.T. 2x #2 S.Y.P. SILL PLATE
CORNER AND OPENING AND 3"x3"x1/4" WASHER AND NUT
WITH 5/8"x12" J-BOLT; SPACING 48" O.C. AND WITHIN 8" OF EACH
2x WALL FRAMING PER PLANS
4"
PER SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB
B
S2 S2
NOT TO SCALE
FOOTING DETAIL (OPTION)
MONOLITHIC STEP DOWN
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
dean.spencer.pe@gmail.com
AL #40501
FL #88877
MAXWELL M. SPENCER, PE
AL #29262, CA #3467
FL #44472, CA #9070
SECB (2006 TO MAR 2022)
DEAN A. SPENCER, PE
850.932.8730 (Voice)
GULF BREEZE, FL 32563
1197 TIGER TRACE BLVD
DEAN A. SPENCER ENGINEERING, INC.
SHEATHING PER SHEATHING NOTES
2023, SECTION 1404.2 OVER STRUCTURAL
APPROVED MOISTURE BARRIER PER FBC
APPROVED EXTERIOR CLADDING OVER
SHEATHING PER SHEATHING NOTES
2023, SECTION 1404.2 OVER STRUCTURAL
APPROVED MOISTURE BARRIER PER FBC
APPROVED EXTERIOR CLADDING OVER
SHEATHING PER SHEATHING NOTES
2023, SECTION 1404.2 OVER STRUCTURAL
APPROVED MOISTURE BARRIER PER FBC
APPROVED EXTERIOR CLADDING OVER
SHEATHING PER SHEATHING NOTES
2023, SECTION 1404.2 OVER STRUCTURAL
APPROVED MOISTURE BARRIER PER FBC
APPROVED EXTERIOR CLADDING OVER
SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB PER
NOT TO SCALE
POST BASE DETAIL
SIMPSON STHD##
CORNER POSTS: (1) SIMPSON STHD14
INTERIOR POSTS: (1) SIMPSON STHD10
PORCH POST OPTIONS (U.N.O.):
WHERE LABELED ON PLANS.
SIMPSON STHD## EMBED STRAP
COLUMN; SEE PLANS
STUD PACK OR POST OR
TOP OF SLAB
BEYOND POST EACH WAY
WITHIN MINIMUM 24" EXTENSION
#4 REBAR INSTALLED AT EACH POST
(1/4" SLAB DEPTH)
1" DEEP SAWCUT
INDUCED CRACK
NOT TO SCALE
CONTROL JOINT (C.J) DETAIL
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
NO GREATER THAN 12'-0" O.C. EACH DIRECTION
CONTROL JOINTS RECOMMENDED TO BE SPACED
GRADE NOTES ON SHEET S1.
CONCRETE SLAB PER SLABS-ON-
REINFORCED 3000 PSI 4"
16"
NOT TO SCALE
GRADE BEAM FOOTING DETAIL
3" CLEAR ALL REBAR
(3) #4 OR (2) #5 CONTINUOUS REBAR
COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER CLEAN
PER SLABS-ON-GRADE NOTES ON SHEET S1.
REINFORCED 3000 PSI 4" CONCRETE SLAB
NOT TO SCALE
POST BASE DETAIL
SIMPSON ABU##Z
PT POST (SEE PLAN)
SIMPSON ABU##Z
TOP OF SLAB
VARIES WITH POST SIZE
(1) OR (2) 5/8"x12" J-BOLTS
SIDECOVER
2" MINIMUM
P.T. 2x #2 S.Y.P. SILL PLATE
AND 3"x3"x1/4" WASHER AND NUT
WITHIN 8" OF EACH CORNER AND OPENING
WITH 5/8"x12" J-BOLT; SPACING 48" O.C. AND
RISE/RUN PER ARCHITECTURAL
Fy = 40 KSI f'c = 3000 PSI
1.5" CLEAR FROM TOP/SIDES
3" CLEAR FROM BOTTOM
#4 REBAR; SPACING 16" O.C. EACH WAY
#4 REBAR NOSING REBAR
6" INTO STEMWALL. DRILL AND EPOXY AS NEEDED.
TURN #4 REBAR INTO CMU STEMWALL; 12" INTO STAIRS -
12"
(2) #4 CONT. REBAR
CONCRETE STAIR DETAIL
NOT TO SCALE
CLEAN COMPACTED TREATED SOIL
6 MIL POLY VAPOR BARRIER
CONT. BOND BEAM
VERTICAL REBAR DETAIL
CMU FOUNDATION WALL CORNER
NOT TO SCALE
HORIZONTAL REBAR DETAIL
CMU FOUNDATION WALL CORNER
NOT TO SCALE
CELL (TYP.)
PEA GRAVEL CONC. FILLED
VERT. REINFORCING IN
REINFORCING (TYP)
VERTICAL
REINFORCING NOTES (TYP).
JOINT REINFORCING. SEE
8"x16"x8" CMU BLOCK W/ HORIZONTAL
FOUNDATION DETAILS; MIN. 25" SPLICE
CONT. HORIZONTAL REBAR PER
INDICATED AT INTERIOR WALLS
PROVIDE MINIMUM LENGTHS AS
CORNERS AND INTERSECTIONS.
JOINT REINFORCING SHAPES AT
USE PREFABRICATED "T" AND "L"
REINFORCING NOTES (TYP).
REINFORCING. SEE
HORIZONTAL JOINT
8"x16"x8" CMU BLOCK W/
FROM FOUNDATION DETAILS
MATCH HORIZONTAL REBAR
(2) CORNER REBAR; SIZES SHALL
8/13/2025
S a n ta R o s a C o u n ty
M il to n F lo ri d a
B a x te r
R o a d
R e s id e n c e
This item has been digitally signed and sealed by Maxwell M.
Spencer, PE on 8/13/2025 using a Digital Signature. Printed
MANUFACTURER
GIRDER TRUSS PER
UNDER GIRDER TRUSS
2x #2 SPF STUD PACK
NOT TO SCALE
GIRDER TRUSS DETAIL
BY TRUSS UPLIFT LOADS
CONNECTION DETERMINED
SIMPSON GIRDER
2x #2 SPF DOUBLE TOP PLATE
SPACING PER PLANS
2x #2 SPF STUD;
FOUNDATION ANCHOR SHALL BE LOCATED WITHIN 8" OF STUD PACK.
SPH# EACH STUD OR PLACE ALL-THREAD WITHIN 8" OF STUD PACK.
STRAP STUD PACK AT BOTTOM PLATE AND DOUBLE TOP PLATE WITH SIMPSON
R E
V
IS
IO
N
S
D A
T E
D E
S C
R
IP
T
IO
N
SHEET NUMBER:
DATE:
S H
E E
T T
IT
L
E
P R
O J E
C T
T
IT
L E
SEAL
S3
N O
T E
S /D
E T
A
IL
S
S T
R U
C T
U R
A L
TRUSSES UPLIFT LOADS
SIMPSON CONNECTION FOR
SIMPSON HGT-2BETWEEN 2720 LBS AND 6485 LBS
SIMPSON MGT/HDU4BETWEEN 1015 LBS AND 2720 LBS
SIMPSON H10ABETWEEN 615 LBS AND 1015 LBS
SIMPSON H2.5AUP TO UPLIFT LOAD OF 615 LBS
EQUIVALENT UPLIFT CONNECTORS
TRUSS MANUFACTURER MAY SUBSTITUTE
NOT TO SCALE
CORNER POST TO BEAM DETAIL
Dean A.
Spencer
Engineering, Inc.
#9070
Authorization
#44472
#88877
CHECKED BY: MMS
DRAWN BY: MMS
SIMPSON H2.5A
ENGINEERED TRUSS
TRUSS MANUFACTURER
SPECIFICATION IS NOT PROVIDED BY
THIS DETAIL SHALL ONLY BE USED IF
RAFTER THAT VALLEY PASSES OVER
EACH ENGINEERED TRUSS OR
TIE 2x6 VALLEY TO TOP CHORD OF
SIMPSON LSTA12 STRAP
RAFTER AT VALLEY LOCATION
ENGINEERED TRUSS OR
2x6 #2 SYP LAID FLAT ON
VALLEY
NOT TO SCALE
VALLEY TIE-IN DETAIL
SYP VALLEY TIE RAFTER
2x4 ENGINEERED TRUSS OR #2
PLATE SHALL BE USED.
RAFTER. IF 2x12 RAFTER, LVL RIDGE
RIDGE PLATE: 1 SIZE LARGER THAN
2x4 #2 SYP COLLAR TIE
EVERY OTHER RAFTER
WHERE THEY FIT
SIMPSON LSTA24 OVER EACH RAFTER SET
NOT TO SCALE
RAFTER/RIDGE PLATE DETAIL
OVER ROOFING
2x12 #2 SYP AT 16" O.C. 19'-0" MAX 2x12 #2 SYP AT 24" O.C. 14'-3" MAX
2x10 #2 SYP AT 16" O.C. 15'-0" MAX 2x10 #2 SYP AT 24" O.C. 11'-6" MAX 2x8 #2 SYP AT 16" O.C. 11'-11" MAX 2x8 #2 SYP AT 24" O.C. 9'-2" MAX 2x6 #2 SYP AT 16" O.C. 8'-8" MAX 2x6 #2 SYP AT 24" O.C. 7'-0" MAX
(OVERROOFING AS REQUIRED):
RAFTER FRAMING
NOT TO SCALE
PARALLEL TRUSS DETAIL
EXTERIOR WALL WITH
ROOF SHEATHING
GYP. BOARD
SHEATHING; SEE TRUSS NOTES
7/16" APA RATED CEILING
REQUIREMENTS
WALL SECTIONS FOR TIE-DOWN
EXTERIOR WALL; SEE TYPICAL
TRUSS MANUFACTURER
ENGINEERED TRUSSES BY
PLATE;
TRUSS BOTTOM CHORD TO TOP
SIMPSON SD SCREWS FROM
SIMPSON GA2 WITH (6) #9x1-1/2"
SPACING 24" O.C.
(FLAT);
2x6 #2 SYP BLOCKING
SPACING 24" O.C.
BOTTOM CHORD EACH SIDE
EACH BLOCK TO TRUSS
(2) 16d COMMON TOE-NAILS
DOUBLE TOP PLATE;
AND NUT EACH END FROM BLOCKING TO
5/8" A307 BOLT WITH 2"x2"x1/4" WASHER
SPACING 24" O.C.
3" CLEAR BETWEEN SCREWS.
1.25" CLEAR FROM EDGE OF LUMBER.
3-1/2" SCREW) MAY REPLACE BOLT.
OPTION: (2) SIMPSON SDS25312 (1/4" x
AT CORNERS: (4) SIMPSON MSTA## - (2) EACH BEAM
POST TO BEAM: (2) SIMPSON MSTA##
P.T. POST; SEE PLANS
ADEQUATE BEARING AND STRAPPING
REQUIRED FOR BOTH BEAMS TO HAVE
PLANS. PLY JOINT OVER POST AS
BEAM EACH SIDE OF CORNER; SEE
ROD EXTENDING TO FOUNDATION
PROVIDE ADJACENT ALL-THREAD
WHEN UPLIFT EXCEEDS 1200#,
3"x3"x1/4" WASHER AND NUT
BEAM (SEE PLANS)
SOLID 2x STUD PACK UNDER BEAM
OF BEARING STUDS
2x STUD EACH SIDE dean.spencer.pe@gmail.com
AL #40501
FL #88877
MAXWELL M. SPENCER, PE
AL #29262, CA #3467
FL #44472, CA #9070
SECB (2006 TO MAR 2022)
DEAN A. SPENCER, PE
850.932.8730 (Voice)
GULF BREEZE, FL 32563
1197 TIGER TRACE BLVD
DEAN A. SPENCER ENGINEERING, INC.
NOT TO SCALE
MID-WALL BEAM POCKET DETAIL
WASHER AND NUT (SEE PLANS)
BEAM WITH TAKE-UP DEVICE OR 3"x3"x1/4"
ALL-THREAD ROD WITHIN 8" ADJACENT TO
END AND 32" O.C. OVER BEAM
SIMPSON SPH# WITHIN 6" OF BEAM
FRAMING BEARS DIRECTLY ABOVE BEAM.
STRAPS ARE NOT REQUIRED WHERE ROOF
TOP OF DOUBLE TOP PLATE. SIMPSON SPH#
NOTE: BEAM MAY BE PLACED FLUSH WITH
2x WALL FRAMING; TYPICAL
#2 SYP P.T. POST
BEAM (SEE PLANS)
SIMPSON MTS24C ON EACH SIDE OF BEAM
DOUBLE 2x TOP PLATE; TYPICAL
PER TYPICAL SPECIFICATIONS
SPACING 24" O.C. - TOE-NAILS
AND FIRST INTERIOR TRUSS;
BETWEEN TRUSS OVER WALL
PROVIDE 2x BLOCKING
SIMPSON MSTA36
16"+ BEAM: (2)
SIMPSON MSTA24
12"-14" BEAM: (2)
EACH SIDE:
8/13/2025
S a n ta R o s a C o u n ty
M il to n F lo ri d a
B a x te r
R o a d
R e s id e n c e
This item has been digitally signed and sealed by Maxwell M.
Spencer, PE on 8/13/2025 using a Digital Signature. Printed
WINDSTORM OSB SHEATHING
FULL HEIGHT 7/16"
FOUNDATION
FOUNDATION
NOT TO SCALE
(WINDSTORM OSB) OPTION
WALL SHEATHING DETAIL
HEADER AT 3" O.C.
8d COMMON NAILS BOTTOM OF
HEADER PER PLANS AND TABLE,
O.C. ALONG INTERIOR
8d COMMON NAILS 8"
O.C. ALONG SIDES
8d COMMON NAILS 3"
ALONG BOTTOM PLATE
8d COMMON NAILS 3" O.C.
8d COMMON RING SHANK NAILS 6" O.C. ALONG INTERIOR
ROOF DECKING - SEE NOTES
8d COMMON RING SHANK NAILS 3" O.C. ALONG EDGES
8d COMMON NAILS 4"-1/2 O.C. ALONG LOWER TOP PLATE
8d COMMON NAILS 3" O.C. ALONG UPPER TOP PLATE
8d COMMON NAILS AT 3" O.C.
P.T. 2x #2 S.Y.P. SILL PLATE U.N.O.
R E
V
IS
IO
N
S
D A
T E
D E
S C
R
IP
T
IO
N
SHEET NUMBER:
DATE:
S H
E E
T T
IT
L
E
P R
O J E
C T
T
IT
L E
SEAL
S4
N O
T E
S /D
E T
A
IL
S
S T
R U
C T
U R
A L
(ALL-THREAD REQUIRED AT ALL LOCATIONS AS SPECIFIED ON THESE DETAILS)
OPTION 1: ALL-THREAD TIE-DOWN SYSTEM
Dean A.
Spencer
Engineering, Inc.
#9070
Authorization
#44472
#88877
CHECKED BY: MMS
DRAWN BY: MMS
(ALL-THREAD LOCATION AS LABELED ON PLANS AND PER ADDITIONAL NOTES)
OPTION 2: WINDSTORM OSB TIE-DOWN SYSTEM
WALL PLATE TO TRUSS JOINT; PROVIDE PANELS TALLER THAN THE WALL SYSTEM AS REQUIRED.
CONTINUOUS SPAN. WINDSTORM PANELS AT GABLE END WALLS SHALL EXTEND ACROSS THE GABLE END
8. WINDSTORM OSB PANELS SHALL EXTEND FULL HEIGHT FROM BOTTOM PLATE TO DBL TOP PLATE IN ONE
7. 1/2" ALL-THREAD SHALL BE LOCATED EACH SIDE OF EACH PLATE HEIGHT CHANGE.
A) OPENINGS EXCEEDING 72" IN WIDTH SHALL BE STRAPPED PER ALL-THREAD TIE-DOWN SYSTEM DETAILS.
6. 1/2" ALL-THREAD SHALL BE LOCATED EACH SIDE OF ALL OPENINGS EXCEEDING 72" IN WIDTH.
5. 1/2" ALL-THREAD SHALL BE LOCATED PER GARAGE DOOR DETAILS AS REQUIRED; SEE DETAILS.
4. 1/2" ALL-THREAD SHALL BE LOCATED WITH 8" FROM EACH BEAM POCKET FOR ALL PORCH BEAMS; SEE DETAIL.
WINDSTORM OSB TIE DOWN SYSTEMIS NOT USED.
3. 1/2" ALL-THREAD SHALL BE LOCATED AT ALL INTERIOR BEARING WALLS (PER ALL-THREAD DETAILS) WHERE
2. 1/2" ALL-THREAD SHALL BE LOCATED AT ALL GIRDER TRUSSES WHEN UPLIFT EXCEEDS 1200#.
1. 1/2" ALL-THREAD SHALL BE LOCATED 8" EACH END OF EACH SHEAR WALL (SEE FLOOR PLAN FOR LOCATIONS).
WINDSTORM OSB TIE-DOWN ADDITIONAL NOTES:
9. BLOCKING SHALL BE INSTALLED WHEN *PANEL-WIDTH IS LESS THAN THE SPECIFIED WIDTH BELOW.
5) WALLS EXCEEDING 10'-1" IN HEIGHT SHALL BE BLOCKED AT MIDSPAN MINIMUM.
4) *PANEL-WIDTH - WALL WIDTH BETWEEN OPENING AND CORNER AND WALL WIDTH BETWEEN OPENINGS.
3) 10'-1" WALLS: PANEL-WIDTH 5'-0" AND LESS SHALL BE BLOCKED AT MIDSPAN.
2) 9'-1" WALLS: PANEL-WIDTH 4'-6" AND LESS SHALL BE BLOCKED AT MIDSPAN.
1) 8'-1" WALLS: PANEL-WIDTH 4'-0" AND LESS SHALL BE BLOCKED AT MIDSPAN.
SHEATHING SHALL BE NAILED TO BLOCKING PER TYP. SPECIFICATIONS.
WINDSTORM OSB SHEATHING
BE INSTALLED ON SAME SIDE AS
SIMPSON HURRICANE CLIP SHALL
TO DOUBLE TOP PLATE INTERIOR SIDE
SHALL BE INSTALLED AT 32" O.C. FROM STUD
SIDE OF WALL; SIMPSON SDWC15600 SCREW
IF HURRICANE CLIP IS INSTALLED ON INTERIOR
NOT TO SCALE
HURRICANE CLIP TO WALL DETAIL
WINDSTORM OSB TIE-DOWN
WINDSTORM OSB SHEATHING
FULL HEIGHT 7/16"
OPENING AND 3"x3"x1/4" WASHER AND NUT
AND WITHIN 8" OF EACH CORNER AND
WITH 5/8"x12" J-BOLT; SPACING 48" O.C.
P.T. 2x #2 S.Y.P. SILL PLATE
SHEATHING NOTES)
OSB TIE-DOWN NOTES AND
(SEE ADDITIONAL WINDSTORM
PANEL WIDTHS ARE NOT MET.
2x BLOCKING WHEN MINIMUM
OPENING AND 3"x3"x1/4" WASHER AND NUT
AND WITHIN 8" OF EACH CORNER AND
WITH 5/8"x12" J-BOLT; SPACING 48" O.C.
P.T. 2x #2 S.Y.P. SILL PLATE
PER HEADER AND STUD TABLE
NUMBER OF JACK AND KING STUDS
SDWC15600 SCREW SPACING TO 16" O.C.
EQUAL TO 36', INCREASE SIMPSON
IF ROOF SPAN IS GREATER THAN OR
NOTE: SPECIFIC HEADER CALLOUTS AS NOTED ON THE PLANS OVERRIDE TABLE ABOVE.
AVAILABLE HEADER OPTIONS AS NECESSARY.
REFERENCED, HEADER SIZE MAY BE REDUCED. COORDINATE WITH E.O.R. FOR ADDITIONAL
WHERE FLOOR AND/OR ROOF SPANS ARE SIGNIFICANTLY SMALLER THAN THE ABOVE
NOTE: OPENINGS SUPPORTING A GIRDER TRUSS SHALL BE 2-PLY 1-3/4" x 11-7/8" LVL MINIMUM.
OPENINGS EXCEEDING 13'-0": SEE FLOOR PLAN FOR HEADER SIZE.
OPENING SIZE 10'-1" TO 13'-0" - 2-PLY 1-3/4" x 11-7/8" LVL
OPENING SIZE 7'-1" TO 10'-0" - (3) 2x12 OR 2-PLY 1-3/4" x 9-1/4" LVL
OPENING SIZE 5'-1" TO 7'-0" - (2) 2x12 OR (3) 2x10
OPENING SIZE 3'-1" TO 5'-0" - (2) 2x10 OR (3) 2x8
OPENING SIZE 3'-0" OR LESS - (2) 2x8 OR (3) 2x6
TOP FLOOR OF STRUCTURE BEARING ROOF SYSTEM UP TO 40' TRUSS SPAN:
**HEADERS SHALL BE INSTALLED AT TOP OF OPENING AS SHOWN ON DETAILS.**
**HEADERS SHALL BE ASSEMBLED AS A SOLID MEMBER - NO SPACES BETWEEN COMPONENTS.**
OPENING HEADER REQUIREMENTS SPAN TABLE:
4414'-1" TO 18'-0"
3310'-1" TO 14'-0"
236'-1" TO 10'-0"
224'-1" TO 6'-0"
21LESS THAN OR EQUAL TO 4'-0"
# KING STUDS# JACK STUDSOPENING SIZE
JACK (HEADER) AND KING STUD REQUIREMENTS:
FOUNDATION
SIMPSON LSTA18
NOT TO SCALE
STRAPPING DETAIL (ALL-THREAD)
HEADER CONNECTION &
CONNECTORS; SEE PLANS
ROOF FRAMING AND
UNLESS NOTED OTHERWISE
STUDS; SPACING 16" O.C.
IF REQUIRED, 2x CRIPPLE
EACH JACK STUD
SIMPSON MSTA24 AT
HEADER PER PLANS AND TABLE
OR CRIPPLE AT 32" O.C.
TOP PLATE TO HEADER
SIMPSON SPH# AT DBL.
PER HEADER AND STUD TABLE
NUMBER OF JACK AND KING STUDS
WINDOW SILL FRAMING AS REQUIRED
OPENING AND 3"x3"x1/4" WASHER AND NUT
AND WITHIN 8" OF EACH CORNER AND
WITH 5/8"x12" J-BOLT; SPACING 48" O.C.
P.T. 2x #2 S.Y.P. SILL PLATE
FOUNDATION
UNLESS NOTED OTHERWISE
2x STUDS; SPACING 16" O.C.
O.C. ALONG INTERIOR
8d COMMON NAILS 8"
ALONG EDGES AT BLOCKING
8d COMMON NAILS 3" O.C.
O.C. ALONG INTERIOR
8d COMMON NAILS 8"
O.C. ALONG EDGES
8d COMMON NAILS 3"
SHEATHING SEAM
2x BLOCKING AT
ROOF DECKING
NAILS 3" O.C. ALONG EDGES
8d COMMON RING SHANK
NOT TO SCALE
(ALL-THREAD)
WALL SHEATHING DETAIL
OPENING AND 3"x3"x1/4" WASHER AND NUT
AND WITHIN 8" OF EACH CORNER AND
WITH 5/8"x12" J-BOLT; SPACING 48" O.C.
P.T. 2x #2 S.Y.P. SILL PLATE
PER SHEATHING NOTES
STRUCTURAL WALL SHEATHING
8d COMMON NAILS 4-1/2" O.C. ALONG LOWER TOP PLATE
8d COMMON NAILS 3" O.C. ALONG UPPER TOP PLATE
NOT TO SCALE
(WINDSTORM OSB) OPTION
HEADER CONNECTION
P.T. 2x #2 S.Y.P. SILL PLATE
AND 3"x3"x1/4" WASHER AND NUT
WITHIN 8" OF EACH CORNER AND OPENING
WITH 5/8"x12" J-BOLT; SPACING 48" O.C. AND
NOT TO SCALE
2x SINGLE STORY STRUCTURAL WALL SECTION
ARCHITECTURAL FEATURES AND CLADDING SPECIFICATIONS.
REFER TO ARCHITECTURAL FOR ALL PROJECT SPECIFIC
EXCEED 12" ABOVE FINISHED GRADE
SUBSTITUTED IF FFE DOES NOT
MONOLITHIC FOUNDATION MAY BE
SEE FOUNDATION DETAILS
OF CORNERS AND OPENINGS
BOLT AT 48" O.C. & 8" EACH SIDE
COUPLED TO "J" ALL-THREAD
COUPLING NUT
FINISHED GRADE
SCHEDULE ON SHEET S1.
2x STUDS PER WALL FRAMING
1/2" GYP. BOARD
APPROVED INSULATION
5/8" GYP. BOARD
MANUFACTURER SPECIFICATIONS
SIMPSON HURRICANE CLIP PER TRUSS
CONT. DRIP EDGE
SEE ARCHITECTURAL
BY TRUSS MANUFACTURER
PRE-ENGINEERED ROOF TRUSSES
PER FBC 2023; SECTION 1203.2
ATTIC VENTILATION SHALL BE PROVIDED
UNDERLAYMENT PER FBC 2023, SECTION 1507.1.1.
APPROVED SHINGLES OVER AN APPROVED
APPROVED INSULATION
ALL-THREAD RODS SHALL BE INSTALLED PER NOTES AND DETAIL.
8d COMMON NAILS AT 3" O.C. ALONG BOTTOM PLATE
8d COMMON NAILS AT 3" O.C. ALONG EDGE
8d COMMON NAILS AT 8" O.C. FIELD
8d COMMON NAILS AT 4-1/2" O.C. ALONG LOWER TOP PLATE
8d COMMON NAILS AT 3" O.C. ALONG UPPER TOP PLATE
FULL HEIGHT 7/16" WINDSTORM OSB SHEATHING:
TIE-DOWN OPTION-
dean.spencer.pe@gmail.com
AL #40501
FL #88877
MAXWELL M. SPENCER, PE
AL #29262, CA #3467
FL #44472, CA #9070
SECB (2006 TO MAR 2022)
DEAN A. SPENCER, PE
850.932.8730 (Voice)
GULF BREEZE, FL 32563
1197 TIGER TRACE BLVD
DEAN A. SPENCER ENGINEERING, INC.
DOUBLE 2x TOP PLATE; TYPICAL
2x KING STUDS PER TABLE
2x JACK STUDS PER TABLE
DOUBLE 2x TOP PLATE; TYPICAL
UNLESS NOTED OTHERWISE
2x STUDS; SPACING 16" O.C.
DOUBLE 2x TOP PLATE; TYPICAL
UNLESS NOTED OTHERWISE
STUDS; SPACING 16" O.C.
IF REQUIRED, 2x CRIPPLE
8d COMMON NAILS AT 3" O.C.
WINDOW SILL FRAMING AS REQUIRED
8d COMMON NAILS AT 3" O.C.
2x HEADER STUDS PER TABLE U.N.O.
8d COMMON NAILS AT 4" O.C.
2x KING STUDS PER TABLE U.N.O.
NAILS AT 4.5" O.C.
LOWER TOP PLATE: 8d COMMON
NAILS AT 3" O.C.
UPPER TOP PLATE: 8d COMMON
DOUBLE 2x TOP PLATE U.N.O.
SHEATHING PER SHEATHING NOTES
2023, SECTION 1404.2 OVER STRUCTURAL
APPROVED MOISTURE BARRIER PER FBC
APPROVED EXTERIOR CLADDING OVER
DOUBLE 2x TOP PLATE; TYPICAL
PER FBC 2023, SECTION 1410.
APPROVED SOFFIT ASSEMBLY
WRAPPED W/ BREAK METAL
2x6 #2 S.Y.P. FASCIA
PER SHEATHING NOTES
STRUCTURAL ROOF SHEATHING
OR 3"x3"x1/4" WASHER AND NUT
SIMPSON RTUD# WITH SIMPSON BPRTUD#
ENGINEER RECOMMENDED TAKE-UP DEVICE:
OR 3"x3"x1/4" WASHER AND NUT
SIMPSON RTUD# WITH SIMPSON BPRTUD#
ENGINEER RECOMMENDED TAKE-UP DEVICE:
OR 3"x3"x1/4" WASHER AND NUT
SIMPSON RTUD# WITH SIMPSON BPRTUD#
ENGINEER RECOMMENDED TAKE-UP DEVICE:
STUD WALL.
BE INSTALLED EXTERIOR FACE OF
SEE PLANS.CONNECTORS SHALL
ROOF FRAMING AND CONNECTORS;
CONNECTORS; SEE PLANS
ROOF FRAMING AND
FACE OF STUD WALL.
BE INSTALLED EXTERIOR
PLANS.CONNECTORS SHALL
CONNECTORS; SEE
ROOF FRAMING AND
6" O.C. ALONG INTERIOR
8d COMMON RING SHANK NAILS
WITHIN 8" OF EACH OPENING AND WALL END.
ALL-THREAD ROD; SPACING 48" O.C. AND
WITHIN 8" OF EACH OPENING AND WALL END.
ALL-THREAD ROD; SPACING 48" O.C. AND
8/13/2025
S a n ta R o s a C o u n ty
M il to n F lo ri d a
B a x te r
R o a d
R e s id e n c e
This item has been digitally signed and sealed by Maxwell M.
Spencer, PE on 8/13/2025 using a Digital Signature. Printed
| Seal Letter SRCHP Stokes |
| SRCHP Structural - 13 August 2025 |
| 2 |
| 3 |
| 4 |
| 2025-08-13T08:25:43-0500 | |
| Maxwell Spencer |
File details come from the government source that posted it. Updated .