New_Const_Permit_8616_Baxter_Rd_SRCDS.pdf
PDF 3 MB Posted
- Attached to
- City Hall Wind Mitigation
- Solicitation number
- 26-008
- Issued by
- Santa Rosa County, Mount Carmel CDP, Florida
About this file
This document is an Onsite Sewage Treatment and Disposal System (OSTDS) Construction Permit issued by the Florida Department of Environmental Protection for a property located at 8616 Baxter Road in Milton, Florida. The permit is for a new septic system installation, specifically a 900-gallon septic tank with a 375 square foot drainfield. The system is designed for a 3-bedroom residential property with a maximum occupancy of 6 persons, with an estimated daily wastewater flow of 300 gallons. The permit was issued on 10/30/2025 and is valid until 04/30/2027.
The property, owned by David P. Stokes Jr. and Gladys Rene Masters Stokes, is a 0.97-acre parcel zoned as Rural Residential Agriculture. The site evaluation indicates a standard trench configuration with no fill required and a bottom drainfield depth of 72 inches. The permit requires abandoning the existing uncertified septic tank in accordance with current regulations and maintaining all setbacks as specified in Florida Administrative Code 62-6. The property's 2025 preliminary land value is $23,280, with a total just market value of $63,839, and the property has disability, homestead, and senior exemptions.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL PROTECTION
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM (OSTDS)
CONSTRUCTION PERMIT
Permit No. 57-S0-5164837 Application No. AP4287897
Date Paid: 10/22/2025 Fee Paid: 55
Receipt No. 57-PID-9364566 Document No. PR4299582
Facility ID. 57-5164837 Type [ X ] New System [ ] Existing System Modification [ ] Repair [ ] Abandonment [ ] Temporary
Subtype [ ] Aerobic Treatment Unit [ ] Non-Innovative PBTS [ ] Innovative PBTS [ ] Innovative Non PBTS [ ] Holding Tank [ ] Other (describe)
Applicant: David Stokes
Property Address: 8616 Baxter Rd City Milton State FL Zip 32583
Lot: Block: Subdivision:
Property ID No. 16-1N-27-0000-00129-0000 [Section, Township, Range, Parcel Number, or Tax ID No.]
The system must be constructed in accordance with specifications and standards of Section 381.0065, F.S., and Chapter 62-6, F.A.C.
Department approval of system does not guarantee satisfactory performance for any specific period of time. Any change in material facts, which served as a basis for issuance of this permit, require the applicant to amend the permit application. Such amendments may result in voiding this permit. Issuance of this permit does not exempt the applicant from compliance with other federal, state, or local permitting required for development of this property.
SYSTEM DESIGN AND SPECIFICATIONS
Tank
900 Gallons / GPD capacity [ X ] Septic Tank [ ] Aerobic Treatment Unit [ ] Multi-chambered [ ] In series
Gallons / GPD capacity N/A [ ] Multi-chambered [ ] In series
Gallons Grease Interceptor capacity
Gallons Dosing Tank capacity gallons at doses per 24 hours doses per 24 hours
Drainfield 375 Square feet primary drainfield system
Square feet N/A system
System type [ X ] Standard [ ] Filled [ ] Mound [ ]
Configuration [ X ] Trench [ ] Bed [ ]
Location of benchmark/reference point Nail w/ metal cap and orange tape in tree
Elevation of proposed system site 42 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point
Bottom of drainfield to be 72 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point
Fill required 0 inches Excavation required inches
Other Abandon the existing uncertified septic tank in accordance with current regulations. Install a new 900 gal septic tank system with 375 sq ft drainfield.
Maintain all setbacks in accordance with FAC 62-6. The above must be completed prior to Final Inspection & Approval. A re-inspection fee will be charged for additional inspections. Department approval of the system does not guarantee satisfactory performance for any specific period of time. The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd.
Specifications by Charles F Oker Private Site Evaluator Printed Name Title Signature
Approved by Brooke Proffitt Environmental Specialist I FDEP-DWRM
Printed Name Title Office Signature
Date issued 10/30/2025 Expiration date 04/30/2027
DEP 4016 07/2025, Construction Permit and Inspection, Part 1 of 2 (Obsoletes all previous editions which may not be used) Incorporated: subsection 62-6.003(1), F.A.C. Page 1 of 3
Brooke Proffitt Approved
| download - 2025-10-30T142626.043.pdf |
| New Construction App_8616 Baxter Rd_Stokes_SRCDS.pdf |
File details come from the government source that posted it. Updated .