Attachment VIII - Questions and Answers PJM2025.pdf

PDF 274 KB Posted

Attached to
PJM 2025 - Electricity
Solicitation number
SPE60425R0405
Issued by

About this file

This document is an Attachment VIII - Questions and Answers (Q&A) for the PJM 2025 Electricity solicitation (SPE60425R0405) issued by the Defense Logistics Agency Energy. The Q&A document contains 69 detailed questions and responses from potential suppliers regarding various aspects of the electricity supply contract, covering topics such as account specifics, billing methods, usage changes, generation projects, transmission credits, and contract terms for multiple Department of Defense and Federal civilian agency facilities within the PJM Regional Transmission Organization market area.

Key highlights include clarifications about specific contract line items (CLINs) for locations like Naval Research Lab, Princeton Plasma Physics Laboratory (PPPL), Argonne National Laboratory, and various military installations. The responses address technical details such as behind-the-meter generation, anticipated load changes, billing methodologies, pass-through charges, and potential facility modifications. The government consistently refers respondents to Amendment 0001 for updated information and notes that offerors may submit additional questions with their proposals. The contract covers a 24-month period beginning December 2025, with an estimated total quantity of 5,600,214,972 kWh and will utilize Locational Marginal Pricing (LMP) for electricity supply.

View the file

Other files

File Type Posted
Continuation Pages SPE60425R0405 A0013.pdf PDF
SF30 SPE60425R0405 A0013.pdf PDF
Solicitation SPE60425R0405 A0012.pdf PDF
SF30 SPE60425R0405 A00012.pdf PDF
Solicitation SPE60425R0405 A0011.pdf PDF
SF30 SPE60425R0405 A0011.pdf PDF
SF30 SPE60425R0405 A0010.pdf PDF
Solicitation SPE60425R0405 A0010.pdf PDF
Attachment VII - Pricing Sheet PJM 2025 A0010.xlsx XLSX spreadsheet
Attachment I - Installation Data Sheet PJM 2025 A0010.xlsx XLSX spreadsheet
Attachment VII - Pricing Sheet PJM 2025 A0009.xlsx XLSX spreadsheet
Attachment I - Installation Data Sheet PJM 2025 A0009.xlsx XLSX spreadsheet
Solicitation SPE60425R0405 A0009.pdf PDF
SF30 SPE60425R0405 A0009.pdf PDF
SF30 SPE60425R0405 A0008.pdf PDF
Solicitation SPE60425R0405 A0008.pdf PDF
Attachment VII - Pricing Sheet PJM 2025 A0007.xlsx XLSX spreadsheet
Solicitation SPE60425R0405 A0007.pdf PDF
SF30 SPE60425R0405 A0007.pdf PDF
Attachment I - Installation Data Sheet PJM 2025 A0007.xlsx XLSX spreadsheet
Solicitation SPE60425R0405 A0006.pdf PDF
SF30 SPE60425R0405 A0006.pdf PDF
Attachment I - Installation Data Sheet PJM 2025 A0005.xlsx XLSX spreadsheet
SF30 SPE60425R0405 A0005.pdf PDF
Solicitation SPE60425R0405 A0005.pdf PDF
Attachment VII - Pricing Sheet PJM 2025 A0005.xlsx XLSX spreadsheet
SF30 SPE60425R0405 A0004.pdf PDF
Attachment I - Installation Data Sheet PJM 2025 A0004.xlsx XLSX spreadsheet
Solicitation SPE60425R0405 A0004.pdf PDF
Attachment VII - Pricing Sheet PJM 2025 A0004.xlsx XLSX spreadsheet
Solicitation SPE60425R0405 A0003.pdf PDF
SF30 SPE60425R0405 A0003.pdf PDF
Attachment I - Installation Data Sheet PJM 2025 A0003.xlsx XLSX spreadsheet
Attachment VI - Argonne Invoice Format A0002.pdf PDF
Solicitation SPE60425R0405 A0002.pdf PDF
Attachment I - Installation Data Sheet PJM 2025 A0002.xlsx XLSX spreadsheet
SF30 SPE60425R0405 A0002.pdf PDF
Attachment I - Installation Data Sheet PJM 2025 A0001.xlsx XLSX spreadsheet
SF30 SPE60425R0405 A0001.pdf PDF
Solicitation SPE60425R0405 A0001.pdf PDF
Attachment VII - Pricing Sheet PJM 2025 A0001.xlsx XLSX spreadsheet
Attachment VI - Argonne Invoice Format A0001.pdf PDF
Attachment VI - Argonne Invoice Format.pdf PDF
Attachment VII - Pricing Sheet PJM 2025.xlsx XLSX spreadsheet
Attachment II - Proposal Requirements PJM2025.pdf PDF
Attachment I - Installation Data Sheet PJM 2025.xlsx XLSX spreadsheet
Attachment III - Representations Certifications and Other Statements PJM2025.pdf PDF
Solicitation SPE60425R0405.pdf PDF
Attachment IV - Small Business Subcontracting Plan Form (Dec 2023).pdf PDF
Attachment V - MPO Invoice Instructions.pdf PDF
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPE60425R0405 PJM 2025 Electricity

Attachment VIII - Questions and Answers PJM2025

1. For purposes of transparency and consistency across suppliers, will you be circulating all Q&A to all participants?

DLA Energy Response: Within this document, the Government is responding to all questions received in response to the solicitation. Any items submitted that are not responded to here have been determined to be exceptions to the terms and conditions of the solicitation and may be submitted within your proposal for further consideration.

Offerors are also welcome to submit within their proposal additional questions not addressed herein.

2. Do any of the facilities in this RFP have existing (placed in service within the last 12 months) or planned behind-the-meter generation, including but not limited to, cogeneration, solar, wind, fuel cell, etc. beyond what is disclosed on Note 1 on page 6? If so, please provide as many details as possible including installation date, fuel type, historic output, intended future output, etc.

DLA Energy Response: The Government is not aware of any additional recent or planned behind-the-meter generation beyond that already defined in the solicitation.

3. Please provide anticipated future output / operational plans for the 4.5 MW cogen at CLIN 0004 – Naval Research Lab.

DLA Energy Response: Please see Amendment 0001. The Naval Research Lab plans to operate the plant 24/7 with all production being consumed on site.

4. Are any of the facilities besides Letterkenny in this RFP subject to BRAC?

DLA Energy Response: The Government is not aware of BRAC impacting any requirements beyond that which is already defined in the solicitation.

5. Will the electric consumption on the service accounts for CLIN 0027 – Letterkenny – change as part of sale of the EDS? In addition, account numbers / customer numbers often change during the sale of property. Will these be changing? This is especially important given the expected timing of the sale right when the contract begins.

DLA Energy Response: The Government does not anticipate any change in usage at this time.

6. With regards to B802(a)(1) for CLIN 0033, Proposer notes that that most customers explicitly state to NOT gross up metered load for line losses, which was done in the directions for CLIN 0034 B802(a)(2). This is because most customers specifically wish to compare the kWh volume from the EDC meter to what they are being billed by their supplier. Please confirm that the Government wishes to specifically NOT gross up metered load. Note B802(a)(1) still says “the metered load of the account is adjusted for line losses,” which is confusing and could be interpreted as an ask to increase volumes.

DLA Energy Response: Please refer to Amendment 0001. While the initial solicitation did require the metered load to be grossed up for line losses, this has since been revised.

7. B802(c)(1)(i) says it is for CLIN 0033 only but references Argonne PLC – please remove reference to Argonne.

DLA Energy Response: Please refer to Amendment 0001 for revision.

8. Regarding DFARS 252.204-7008 and 252.204-7012, please confirm as with similar past RFPs for the supply of electricity that the Government does not anticipate that any Covered Defense Information (CDI) or other Controlled Unclassified Information (CUI) will be provided to or generated by the contractor performing under the resulting award?

If any such information will be provided or generated under the contract, please identify or describe the information.

DLA Energy Response: No information has been identified as CUI or CDI at this time.

9. With regards to B802(c)(iii) the Government states “The Contractor shall refund to (or charge) the PJM marginal loss credit." Please confirm this is to be “Transmission Loss Credits” which is PJM Billing Line Item # 2220 and is to be passed through, aligning to contract SPE60425D8000, CLINs 0028/0033.

DLA Energy Response: Please refer to B802(c)(1)(iii) which states “The Contractor shall refund to (or charge) the PJM marginal loss credit (PJM Transmission Loss Credit).”

10. With regards to B1.08(e)(1)(ii)(D) for CLINs 0020 and 0021, AEP Ohio utilities (CSPC and OPC) have their own Weather Normalization Factor that is unique for those utilities only and should be included as part of the formula. This process is detailed on AEP’s website.

DLA Energy Response: Please refer to Amendment 0001 clarifying the treatment of the AEP Ohio Weather Normalization Factor in B1.08(e)(1)(ii)(D).

11. With regards to CLIN 0034, Attachment VI suggests dividing by 366, which appears to be an error for leap years – please correct or appropriately notate this formula. The RFP statement looks correct.

DLA Energy Response: Please refer to Amendment 0001 Attachment VI - Argonne Invoice Format A0001.

12. With regards to CLIN 0034, Attachment VI suggests that Transmission Enhancement/RTEP/TES are to be included in the price (they aren’t included on the Invoicing Instructions from Attachment VI), which is counter B802(c)(iii) of SPE604-25- R-0405 (RFP). Please confirm that these costs should be passed through with no markup as suggested in the RFP.

DLA Energy Response: Attachment VI - Argonne Invoice Format A0001 only provides a sample format of how the charges should appear on the invoice for Argonne. Please refer to B802(c)(2)(ii) Transmission which states “All other transmission related costs [other than NITS], including enhancement charges, must be included in the Transaction Fee.”

13. With regards to C800(b)(13), there is a statement that GRT should be passed through for all Pennsylvania accounts. This counters B1.08(e)(2)(i). Please review and confirm treatment for GRT for these groups.

DLA Energy Response: Please refer to Amendment 0001 which removes C800(b)(13) and clarifies the treatment of Pennsylvania Gross Receipts Tax in B1.08(e)(1)(ii)(E) and (e)(2)(ii).

14. With respect to C800(b), Proposer notes that providing the Government demand information and UDC "pass through" charges in its invoices where Government has requested dual billing may not be possible since in these cases, this information would be the responsibility of the UDC to provide on its invoices to the Government.

DLA Energy Response: Contractor invoices shall only include the information required by C800, Paragraph (b)“…if available from the UDC.”

15. With respect to C800(b), Proposer notes that providing the Government any information on invoices for UDC billed groups would not be possible since the UDC renders the bills, outside the control of the Proposer.

DLA Energy Response: See response to Item 14 above.

16. Proposer wishes to clarify that for Ohio accounts, transmission will be invoiced by the UDC, and for accounts for certain Pennsylvania UDC accounts, transmission enhancement will be invoiced by the UDC.

DLA Energy Response: Please refer to C800, Paragraph (a) which states “With the exception of any and all transmission and distribution related charges payable by the Government to the UDC under the applicable tariff for each account… the Contractor is responsible for all costs associated with deliveries to the delivery point and the scheduling and coordination for delivery of electricity to the service point for each account under the contract.” Suppliers shall not attempt to invoice the Government for any transmission and/or transmission enhancement charges in those cases an account is located within a UDC service territory in which the UDC invoices the Government for that same charge.

17. For Argonne, line losses are to be passed through. However, there is no statement as to whether these should be using the Day Ahead LMP or Real Time LMP. Please confirm this should be Day Ahead LMP to align with the index used for the energy.

DLA Energy Response: Please refer to B802, Subparagraph (c)(2)(iii) which states “The Commodity Price shall be consistent with the energy price defined in B802, Subparagraph (a)(2).”

18. Please confirm for all products and line items, are PSC fees to be a full pass through?

DLA Energy Response: It is assumed that PSC fees refer to Public Service Commission fees. Public Service Commission fees shall be included in the price for all CLINs. As stated in Solicitation SPE60425R0405, as revised by Amendment 0001:

For CLINs 0001 – 0027 and 0035: Please refer to B1.08(e)(1)(ii) which lists those charges not included in the price. As PSC fees are not listed in this subparagraph, they shall be included in the price in accordance with B1.08(e)(1)(i) which states the price shall include “(all retail supply costs) to the service point as specified in this solicitation unless explicitly identified in Subparagraph (ii).”

For CLINs 0028 - 0032:

Please refer to B1.08(e)(2)(ii) which lists those charges not included in the price. As PSC fees are not listed in this subparagraph, they shall be included in the price in accordance with B1.08(e)(2)(i) which states “Prices shall include the following charges:

All retail supply costs to the point of receipt as specified in this solicitation unless explicitly identified in Subparagraph (ii)…”

For CLIN 0033 PPPL and CLIN 0034 Argonne: Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. PSC fees are not defined in either B802(a) or (c).

19. Will either PPPL or Argonne make any partial hedges of the % load during the contract term?

DLA Energy Response: The Government does not currently have any requirement beyond that currently defined in this solicitation. Should the Government seek to convert any LMP-based contract line item quantity to a firm-fixed price (for CLINs 0033 or 0034), the process defined in B806 Contract Price Conversion will be followed.

20. Can you confirm that PPPL does not have any additional requirements regarding billing other than DUAL billed by the supplier?

DLA Energy Response: There are no additional invoicing requirements for CLIN 0033 PPPL beyond those already defined in the solicitation.

21. Regarding PPPL and Argonne line items, please confirm the treatment of the below components as pass through items:

a. Black Start

b. Reactive Supply & Voltage Control

DLA Energy Response: For CLIN 0033 PPPL and CLIN 0034 Argonne: Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. Black Start and Reactive Supply & Voltage Control are not defined in either B802(a) or (c).

22. Regarding DLA: PJM, CLIN 0004 Naval Research Lab (DC):

NOTE : 0004 - Naval Research Lab (DC) - Anticipated completion of a 4.5 MW cogeneration plant to be operational in July 2026, contingent upon approved Pepco Interconnection Agreement and separate switchgear replacement.

Regarding the cogen:

a. Is the project still set to be operational July 2026?

DLA Energy Response: Please refer to Amendment 0001. The plant is now estimated to begin operations in the second quarter of FY27 (January – March 2027).

b. Will it be working at full capacity year round?

DLA Energy Response: Please refer to Amendment 0001. The Naval Research Lab plans to operate the plant 24/7.

c. Can DLA please provide forecasted usage?

DLA Energy Response: The Government is unable to provide forecasted usage beyond that already stated in the solicitation.

23. Regarding DLA: PJM, CLIN 0012 Maryland Procurement Office:

NOTE : 0012 - MPO - For the largest BG&E account only, CLIN 0012 began requiring additional usage in January 2025 with usage (in kWh) increasing by an amount approximately equal to 9.2% of the 12-month quantity (in kWh) listed in the installation data sheet for the largest BG&E account.

DLA Energy Response: Please refer to Amendment 0001, MPO Note is removed.

a. Please confirm the "largest" BGE account:

DLA Energy Response: For the purposes of Attachment V - MPO Invoice Instructions, MPO’s largest BGE account is identified on the ‘0012 MPO’ tab within Attachment I – Installation Data Sheet, as revised by Amendment 0001.

b. Please confirm the usage the DLA received for MPO.

DLA Energy Response: DLA Energy has reviewed the usage data provided for CLIN 0012 MPO and confirms the data provided in Attachment I – Installation Data Sheet is consistent with that provided by the relevant utilities.

c. Is the increase of 9.2% still expected to occur and when?

DLA Energy Response: Please refer to response to Item 23 above.

d. Can the DLA provide forecasted monthly usage to address the usage change over time?

DLA Energy Response: Please refer to response to Item 23 above.

24. Regarding DLA: PJM, CLIN 0014 National Agricultural Library (USDA):

NOTE : 0014 - National Agricultural Library (USDA) - Anticipated completion of a repair and maintenance contract FY2025 – FY2027 which includes several AHU replacements and other building improvements that would increase energy efficiency.

DLA Energy Response: Please refer to Amendment 0001, USDA Note is removed.

a. Can the DLA please provide an expected date of completion?

DLA Energy Response: The expected date of completion moved beyond this solicitation’s period of performance.

b. Can they please provide a monthly breakout to show usage after efficiencies are in place?

DLA Energy Response: Please refer Item 24 above.

c. What is the expected deviation from the current historical usage for increased efficiency ?

DLA Energy Response: Please refer Item 24 above.

25. Regarding DLA: PJM, CLIN 0018 Joint Base McGuire Dix Lakehurst (JBMDL):

NOTE : 0018 - Joint Base McGuire Dix Lakehurst (JBMDL) - Smart controls have come online between March 2024 and May 2025 and are expected to reduce consumption by about 15% or more. A total of 27 accounts impacted by smart controls are identified in Installation Data Sheet CLIN 0018 JBMDL.

a. Can you confirm the reduction hasn’t taken place respective of the usage available, and that intends to change 15% from the present volumes?

DLA Energy Response: Smart controls came online between March 2024 – May 2025. Usage data provided is historical usage data up to March 2025, therefore, could only capture the changes of the smart control that were already installed.

b. Please clarify when will this change it take place?

DLA Energy Response: Please refer to B1.08(e) Note “Smart controls have come online between March 2024 and May 2025”.

c. Can you provide context for what value the 15% change will occur?

DLA Energy Response: Please refer to B1.08(e) Note “A total of 27 accounts impacted by smart controls are identified in Installation Data Sheet CLIN 0018

JBMDL”.

d. Can you provide context of the "more" as a cap'd range of expected change? Is that 15% to 20%, Is that 15% to 50%?

DLA Energy Response: The 15 percent value is an estimate only based on efforts relating to an Energy Savings Performance Contract, however it is not possible to provide a more precise value at this time. The Government will use its best efforts to notify Contractor of any substantial deviation in usage to the extent practicable.

26. Regarding DLA: PJM, CLIN 0019 NOTE : 0019 - NJ IDA - IDA CCRP may undergo a construction project to build an addition with a completion date in December 2026, which impact not greater than 10%.

DLA Energy Response: Please refer to Amendment 0001, NJ IDA Note is removed.

a. When is the construction starting?

DLA Energy Response: Please refer to Item 26 above.

b. Is the active construction going to impact their expected load?

c. What is the facility being built, and how will this impact the expected usage?

d. Will the facility have a new meter as not to impact the priced accounts?

27. Regarding DLA : PJM, CLIN 0024 NOTE : 0024 - Carlisle Barracks - Reduction of usage by approximately 200,000 kwh due to the demolition of 3 buildings on the installation.

a. The RFP only includes 2 accounts. Were the accounts associated to the 3 building already removed?

DLA Energy Response: Please refer to Amendment 0001, B1.08(e) NOTE 1 “Reduction of usage by approximately 200,000 kwh annually to account# (notated in the Installation Data Sheet) due to the demolition of 3 buildings on the installation”.

b. Which account is associated with the 3 buildings?

DLA Energy Response: Please refer to Amendment 0001, B1.08(e) NOTE 1 “Reduction of usage by approximately 200,000 kwh annually to account# (notated in the Installation Data Sheet) due to the demolition of 3 buildings on the installation”.

28. Regarding DLA: PJM, CLIN 0025 DLA Susquehanna NOTE : 0025 - DLA Susquehanna - PV solar is underway, anticipated completion at the end of 2025. Conversion of UDC from old material handling system to a new one may have a minor impact. Building 89 will go off natural gas and switch to heat pumps, anticipated June 2026.

a. How large is solar array and which account is it going on?

b. Is project still projected to be operational by end of 2025?

c. Can they please provide forecasted monthly usage for account that will have solar?

d. Which account is associated with Building 89?

DLA Energy Response: Please refer to Amendment 0001 which revises the note in B1.08 to include additional information.

29. Regarding DLA : PJM , CLIN 0033 PPPL:

NOTE : "0033 – PPPL - Due to new construction and experiments coming online, total usage is projected to increase from approximately 20,000 MwH in FY24 to greater than 30,000 MwH by FY27."

DLA Energy Response: Regarding questions 29 a – e below, no more specific information is available at this time. Should more information become available, it will be provided via solicitation amendment.

a. Can the DLA please provide a specific timeline on when the project will start and finish?

b. Can the DLA please provide a specific final volume for after the project?

c. Is usage going to gradually increase or increase all at once? And , when?

d. Can the DLA provide additional context with a expected monthly forecast for change?

e. Can the DLA provide a cap for the range its expected to be greater than 30,000 mwh?

f. Please confirm the Ancillaries are treated as pass through for PPPL?

DLA Energy Response: Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. Ancillaries are not defined in either B802(a)(1) or (c)(1) for PPPL.

g. Can you confirm that TRANSMISSION is a passthrough for PPPL?

DLA Energy Response: Please refer to B802(c)(1)(ii) which lists the transmission charges/credits that shall be passed through for PPPL.

h. Please confirm the treatment of PJM deration credit for PPPL?

DLA Energy Response: PJM Loss Deration shall be included in the Transaction Fee. Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections

(a) and (c) of this section”. B802(c)(1)(iii) lists the transmission and distribution loss charges that shall be passed through for PPPL. As revised by Amendment 0001, this subparagraph now explicitly states PJM’s loss deration shall be included in the Transaction Fee.

i. Please confirm the treatment of RPS for PPPL?

DLA Energy Response: Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. RPS is not defined in either B802(a)(1) or (c)(1) for PPPL.

j. Please confirm the treatment of PJM Marginal Loss Credit for PPPL is a pass through?

DLA Energy Response: Please refer to B802(c)(1)(iii) which listed PJM Marginal Loss Credit as a pass through under Transmission and Distribution Losses for PPPL.

k. Regarding the DA LMP energy product, please confirm this is Day Ahead scheduled and settled real time?

DLA Energy Response: For both CLINs 0033 PPPL and 0034 Argonne, B802 Subparagraphs (a)(1) and (a)(2) respectively stipulate only what the Government is to be charged for energy. In both cases this is based on the Day-ahead LMP for the PJM Residual Metered Load Aggregate Load Zone through which the account is served.

The solicitation does not stipulate the method by which the Contractor chooses to schedule the load. Any additional costs associated with the scheduling or settlement of the load, unless specifically identified in Subparagraphs (c)(1) or (c)(2) respectively, must be included in the Transaction Fee as defined in Paragraph (b).

30. Regarding DLA: PJM, CLIN 0034 Argonne National Laboratory:

NOTE : "0034 - Argonne National Laboratory - The load profile is expected to vary as our supercomputer (demand as high as 57,000 kW) and data center loads fluctuate based on our customers’ requirements. Computer demand is accounted for in projected usage estimates provided in Attachment I - Installation Data Sheet PJM 2025. The Government will use its best efforts to notify Contractor of any substantial deviation in usage to the extent practicable."

a. Please confirm the ARR, MLC, and Ancillaries are the these a pass through for

Argonne?

DLA Energy Response: Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. For Argonne, neither Auction Revenue Rights (ARR), Marginal Loss Credits (MLC), nor Ancillaries are defined in either B802 (a)(2) or (c)(2).

b. Regarding the DA LMP energy product, please confirm this is Day Ahead scheduled and settled real time?

DLA Energy Response: See response to Item 29k above.

31. Can you please review and confirm the usage for 0015 National Institutes of Health (NIH) as it appears overstated by over 1,000 mwh annually? Are there expected changes to that facility in the contract term?

DLA Energy Response: Please refer to Amendment 0001 which corrects incorrect data supplied by the UDC.

32. Can you please review and confirm the usage for 0029 99th Army Reserve (NJ) as it appears overstated by over 1,000 mwh annually? Are there expected changes to that facility in the contract term?

DLA Energy Response: Please refer to Amendment 0001 which corrects incorrect data supplied by the UDC.

33. Can you please review and confirm the usage for 0031 99th Army Reserve PA - Dusquene as it appears understated by over 300 mwh annually? Are there expected changes to that facility in the contract term?

DLA Energy Response: The Government has confirmed that the data provided is within standard range of variability.

34. CILN 0027 does not contain the current account number format for West Penn Power.

Please provide as soon as possible to validate account information.

DLA Energy Response: The Government has no additional information regarding the account numbers for this CLIN at the present time. Should additional information become available, it will be provided as an amendment to the solicitation.

35. The CLIN 0002 Joint Base Henderson-Hall (McNair) is listed in the values as UDC Billed on page 11, but listed as DUAL in the chart in Note 1 on page 12. Please advise which billing method is correct. As there are various pass throughs for the product requested, it is advised that the customer be DUAL billed. Please confirm.

DLA Energy Response: Please refer to Amendment 0001 C800(b). CLIN 0002 Joint Base Henderson-Hall (McNair) will utilize Dual billing.

Similarly, CLIN 0013 Fort Detrick - Forrest Glen has the same issue as above.

DLA Energy Response: Please refer to Amendment 0001 C800(b). CLIN 0013 Fort Detrick – Forrest Glen and CLIN 0017 Fort Detrick will utilize Dual billing.

36. Regarding CLIN 0013 Fort Detrick - Forrest Glen, the account # is a residential account.

The DLA would need to be remove the account do to new regulations in MD. Will the DLA be able to remove this account in a future amendment?

DLA Energy Response: Fort Detrick – Forrest Glen is in the process to reclassify this one account as MGT LV II (Time Metered Medium General Service – Low Voltage – Type II). The Government will re-evaluate the inclusion of this account if the reclassification cannot be completed in a timely manner.

37. The below accounts are the rows of the rejected / invalid account information from the accounts tab of the exhibit.

CLIN 0007 FORT MEADE – 1 BGE account CLIN 0018 JBMDL – 3 JCP&L accounts CLIN 0023 Bettis – 1 Duquesne Light account

DLA Energy Response: Please refer to Attachment I – Installation Data Sheet A0001 for updates on these accounts.

38. Will all CLINS be contracting with the same supplier, by individual CLINS or contracting per group?

DLA Energy Response: Please refer to Attachment II – Proposal Requirements PJM2025, section F: “Offerors may submit prices on all, some or none of the line items contained in the solicitation.”

39. Regarding the installation data-75 of the West Penn Power accounts (#0027, Letterkenny Army Depot), only have listed account numbers, not the Customer Number, please provide.

DLA Energy Response: Please refer to Item 34 above.

40. 0024-Carlisle Barracks - SUPPLIER needs to know when DLA CLIN 0024 (Carlisle Barracks) will begin/end the demolition of 3 buildings on the installation in order to accurately adjust usage (reduction of 200,000 kwh) for pricing in accordance with the RFP's anticipated load changes (Page 6 of 30) in the Solicitation.

DLA Energy Response: Please refer to Amendment 0001, B1.08(e) NOTE 1.

41. 0025-Susquehanna - Do you have the PV solar array (KW) that needs to be applied to LDC # under the Susquehanna opportunity for DLA DLA Energy Response: Please refer to Item 28 above.

42. Given the flow starts are not until December 2025, will the projected auction likely be held over the summer months or during the fall season?

DLA Energy Response: Please refer to Attachment II - Proposal Requirements PJM2025, section F. PRICE which states, “the date and time for pricing will be established at a later date and communicated to all offerors via solicitation amendment”.

Currently, DLA Energy has not established a pricing date.

Furthermore, the Proposal Requirements also states, “prices shall be submitted by utilizing the solicitation Attachment titled “Pricing Sheet PJM 2025”. DLA Energy does not intend to use Reverse Auction for this Solicitation SPE60425R0405.

43. Offeror understands the need to hold prices firm for 4 hours, but please confirm the contractor may request the right to withdraw its price(s) at any time prior to bid being awarded.

DLA Energy Response: Please refer to FAR 52.212-2, Paragraph (c).

44. Will there be another opportunity to submit questions once the account lists and pricing groups are finalized?

DLA Energy Response: Please refer to the response to Question 1.

45. Will all supplier questions and DLA responses be released in aggregate form to help ensure that all suppliers have access to a common set of information as a means to decrease potential ambiguity on how the DLA requirements are being interpreted independently by each supplier?

DLA Energy Response: Please refer to the response to Question 1.

46. As noted in B1.08.e.1.(i), the prices for CLINs #0001 through #0027 (FFP) shall include “new or modified charges resulting from PJM’s reserve price formation and reserve market enhancements implementation shall be considered part of ancillary services and shall be included in the Firm Fixed-Price for all CLINs”. To the extent that PJM is continuously reforming their best practices and market enhancements, and the difficulty in predicting their decisions as such, please confirm that these instead will be handled within the language contained in Section I820 Electricity Regulatory Changes (DLA Energy December 2014)?

DLA Energy Response: Please refer to Amendment 0001 which removes the language referenced in B1.08(e)(1)(i).

47. Is DLA currently aware of any future closing, sale or non-renewal of lease agreements for any buildings that are on this RFP? Specifically, will suppliers be kept whole due to any facilities that terminate this agreement prior to contract expiration? Would the calculation under “Termination for the Government’s Convenience” prevail per Section (l) of the

RFP?

DLA Energy Response: The Government is not aware of any future closing, sale,or non-renewal of lease agreements for any buildings beyond that already defined in the solicitation. If the Government decides to completely or partially terminate performance of work under a contract when it is in the Government’s interest, such a termination would be in accordance with FAR 52.212-4(l) TERMINATION FOR THE GOVERNMENT'S CONVENIENCE [TAILORED] of the solicitation.

48. Aside from the listed in the solicitation, is DLA currently aware of any significant usage reductions/growth to current load for any accounts?

DLA Energy Response: The Government is not aware of any significant usage reductions/growth to load beyond that already defined in the solicitation.

49. Aside from what is already noted, do any of the facilities in this solicitation have existing or planned behind-the-meter generation. If so, please provide as many details as possible.

DLA Energy Response: The Government is not aware of any additional recent or planned behind-the-meter generation beyond that already defined in the solicitation.

50. Per Note 1, CLIN 0004 Naval Research Lab is installing a 4.5MW cogen. Please provide details of how this cogen will operate and advise on the output from the cogen offsetting usage that was previously secured from the PJM grid.

DLA Energy Response: Please refer to Items 3 and 22 above.

51. Regarding Attachment #1: There are several account-related eccentricities. Please advise and provide details accordingly:

a. CLIN 0018 – Joint Base McGuire Dix Lakehurst (JBMDL) Please provide the correct “Customer Service” number for the below account, this can be found on the invoice:

NJ JCP&L – 1 account

DLA Energy Response: Please refer to Attachment I - Installation Data Sheet PJM 2025 A0001 for account update.

b. CLIN 0023 – Bettis Account # is listed in the solicitation but there are two additional accounts under contract for it. Please advise.

Bettis – 1 account

DLA Energy Response: Please refer to Attachment I - Installation Data Sheet PJM 2025 A0001 for accounts update.

c. CLIN 0027 – Letterkenny Army Depot Please provide the correct-form “Customer Number” which is 20 digits long for all accounts (i.e.)

DLA Energy Response: Please refer to Item 34 above.

d. CLIN 0007 - Fort Meade Please provide the correct “Customer Service” number for the below accounts, as they all came back as invalid:

Ft. Meade – 3 accounts

DLA Energy Response: Please refer to Attachment I – Installation Data Sheet PJM 2025 A0001 for any updates concerning Ft. Meade accounts. Should any additional information become available, it will be provided via amendment to the solicitation.

e. CLIN 00012 – Marland Procurement Office Please provide the correct “Customer Service” number for the below accounts, as they all came back as invalid:

MPO – 1 account

DLA Energy Response: All Customer Service numbers have been verified as correct and active.

52. Regarding Attachment #1: There are several usage-related eccentricities. Please advise and provide details on what the expected usage would be annually and/or for the 24-month contract term.

a. CLIN0013 – Fort Detrick Forest Glen

One account is marked residential. With recent changes to the MD regulations, serving residential accounts in the State of Maryland is a challenge (as signed by Wes Moore SB1 which took affect on January 1, 2025). As you may already know, residential contracts can not exceed 12 months in length and must be priced at or below the 12 month historic average SOS rate. Please confirm removal of this account from the solicitation and/or if there are plans to reclassify the account to non-residential.

DLA Energy Response: Please refer to Item 36 above.

53. There appears to be inconsistent billing requirements for CLIN 0002 / 0013 / 0017.

Please provide further clarification on whether they are to utilize Consolidated UDC or Dual Billing.

DLA Energy Response: Please refer to Amendment 0001 C800(b). CLIN 0002 Joint Base Henderson-Hall (McNair), 0013 Fort Detrick – Forrest Glen, and CLIN 0017 Fort Detrick will utilize Dual billing.

54. What is the historical and expected magnitude of the “Dedicated Facilities Charge”? Is the charge sent on a recurring cadence (i.e. monthly) or is it sent on an ad hoc basis?

Please provide a sample invoice, along with an estimate of the current charge.

DLA Energy Response: Please refer to Attachment V - MPO Invoice Instructions which states “the Dedicated Facilities Charge shall be billed on a monthly invoice separate from all other electricity supply charges” and other information regarding “Dedicated Facilities Charge”.

55. Is SUT excluded on the NJ sites?

DLA Energy Response:

Please refer to FAR 52.212-4, SubParagraph (k)(1) which states:

“(1) The contract price includes all applicable Federal, State, and local taxes and duties in effect at contract signing. Invoice requirements are expressed in Section B and C. If awarded, a copy of the state(s) sales tax exemption will be distributed (as needed).”

For CLINs 0028 – 0032 only, B1.08(e)(2)(ii) specifically states that New Jersey Sales and Use Tax shall not be included in the unit price.

56. Is a sub account required for any site?

DLA Energy Response: There is no requirement for the Contractor to utilize a sub account for any CLIN under this Solicitation SPE60425R0405.

57. How many of these sites will require WAWF billing?

DLA Energy Response: Please refer to C800(b) Table or DFARS 252.232-7006. There are currently 5 CLINs requiring WAWF billing.

58. Do you have the full name for the highlighted sites below (Credit is seeking this):

a. DIA (DC)

b. DISA

c. CSSG

d. NJ IDA

e. PPPL

DLA Energy Response: Please refer to Attachment I - Installation Data Sheet PJM 2025 A0001.

59. For CLINs 18,19,20,21, and 22. Should taxes be exempt? All 5 CLINs are in either Ohio or New Jersey. It is not called out on the RFP.

DLA Energy Response: Please refer to FAR 52.212-4, Subparagraph (k)(1) which states:

“(1) The contract price includes all applicable Federal, State, and local taxes and duties in effect at contract signing. Invoice requirements are expressed in Section B and C. If awarded, a copy of the state(s) sales tax exemption will be distributed (as needed).”

60. CLIN 0033 (PPPL) – Please confirm how the marginal loss credit (TLC) shall be treated.

Is this a direct passthrough (we believe so based on the language in the RFP under B802).

DLA Energy Response: Please refer to Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. Subparagraph(c)(1)(iii) states “The Contractor shall refund to (or charge) the PJM marginal loss credit (PJM Transmission Loss Credit).”

61. The WPNPW accounts for Letterkenny Army Depot are in the short version. We will need the 20-digit account number to request pricing for those.

DLA Energy Response: Please refer to Item 34 above.

62. Are the New Jersey installations exempt from state sales & use tax? If no, should this be included in the price or as a pass through?

DLA Energy Response: Please refer to Item 55 above.

63. Section B802 – Locational Marginal Price. Are ancillary and RPS costs to be included in the Transaction Fee or passed through?

DLA Energy Response:

For CLIN 0033 PPPL - Please refer to B802(b) which states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”. Neither Ancillaries nor RPS are defined in either B802(a)(1) or (c)(1) for PPPL and therefore shall be included in the Transaction Fee.

For CLIN 0034 Argonne – Please refer to B802(b) Note 1 which states, “RPS for CLIN 0034 Argonne is not included in the transaction fee as Illinois UDCs cover the RPS requirement”.

B802(b) further states “Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section”.

Ancillaries are not defined in either B802(a)(2) or (c)(2) for Argonne and therefore shall be included in the Transaction fee.

64. For CLIN 0004, Naval Research Lab, what is the anticipated load impact of the cogeneration plant?

DLA Energy Response: Please refer to Items 3 and 22 above.

65. For CLIN 0012, MPO’s largest account, should the supplier anticipate the 9.2% increase in usage during the entire contract term, until December 2027?

DLA Energy Response: Please refer to Amendment 0001, CLIN 0012 MPO Note is removed. For the purposes of Attachment V - MPO Invoice Instructions, MPO’s largest BGE account is identified on the ‘0012 MPO’ tab within Attachment I – Installation Data Sheet, as revised by Amendment 0001.

66. For CLIN 0014, National Agriculture Library, should the supplier anticipate periods of shut-down due to repair and maintenance?

DLA Energy Response: Please refer to Amendment 0001, CLIN 0014 National Agriculture Library Note is removed.

67. For CLIN 0025, DLA Susquehanna, please provide the load impact of the PV Solar project, along with the anticipated load shape if available.

DLA Energy Response: Please refer to Item 28 above.

68. Should there be any issues or concerns regarding account data, will suppliers have another opportunity for questions?

DLA Energy Response: Please refer to Attachment II - Proposal Requirements PJM2025, section J. EXCEPTIONS AND QUESTIONS. Additional questions may be submitted with an offeror’s proposal.

69. Would DLA consider changing the pricing format back from emailing to the Online Bidding Platform?

DLA Energy Response: Please refer to Attachment II - Proposal Requirements PJM2025, section F. PRICE which states, “prices shall be submitted by utilizing the solicitation Attachment titled “Pricing Sheet PJM 2025”. DLA Energy does not intend to use Reverse Auction for this Solicitation SPE60425R0405.