Solicitation SPE60425R0405.pdf
PDF 509 KB Posted
- Attached to
- PJM 2025 - Electricity Federal contract opportunity
- Solicitation number
- SPE60425R0405
- Issued by
- Defense Logistics Agency Energy
About this file
This is a federal solicitation (RFP) from the Defense Logistics Agency (DLA) Energy for electricity supply and ancillary services for multiple Department of Defense and Federal Civilian Agency facilities in the PJM Regional Transmission Organization market area. The solicitation (SPE60425R0405) seeks a 24-month contract from December 2025 to December 2027 to supply an estimated 5,600,214,972 kilowatt-hours of electricity across 34 contract line items covering locations in Washington D.C., Maryland, New Jersey, Pennsylvania, Ohio, and other states.
The contract will be awarded on a Firm Fixed Price Requirements Type basis, with most line items using fixed pricing and two line items (for Princeton Plasma Physics Laboratory and Argonne National Laboratory) utilizing Locational Marginal Pricing. The total estimated quantity covers 629 total accounts across various military installations, research laboratories, and federal facilities. Offerors will be evaluated on past performance, technical capability/risk, small business participation, and price, with past performance being the most important non-price evaluation factor. The solicitation is set aside for small businesses, with specific considerations for HUBZone, women-owned, service-disabled veteran-owned, and other small business categories.
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30 1000204201
1. REQUISITION NUMBER
2. CONTRACT NO. 3. AWARD/EFFECTIVE
DATE
4. ORDER NUMBER
SPE604-25-R-0405
5. SOLICITATION NUMBER
2025 JUN 27
6. SOLICITATION ISSUE
DATE
Minna Pham DMP0057
a. NAME
Phone: 571-767-9300
b. TELEPHONE NUMBER (No Collect calls)
2025 JUL 29
8. OFFER DUE DATE/
LOCAL TIME
9. ISSUED BY CODE SPE604
DLA ENERGY
INSTALLATION ENERGY
8725 JOHN J. KINGMAN ROAD
FORT BELVOIR VA 22060
USA
10. THIS ACQUISITION IS UNRESTRICTED OR SET ASIDE: % FOR:
SMALL BUSINESS
HUBZONE SMALL
BUSINESS
WOMEN-OWNED SMALL BUSINESS
(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
8 (A)
SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
221112NAICS:
950 EmployeesSIZE STANDARD:
11. DELIVERYFOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
12. DISCOUNT TERMS
13a. THIS CONTRACT IS A
RATED ORDER UNDER
DPAS (15 CFR 700)
13b. RATING
14. METHOD OF SOLICITATION
RFQ IFB RFP
15. DELIVER TO CODE 16. ADMINISTERED BY CODE
17a. CONTRACTOR/ CODE
OFFEROR
FACILITY
CODE
TELEPHONE NO.
18a. PAYMENT WILL BE MADE BY CODE
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN
OFFER
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK
BELOW IS CHECKED
19.
ITEM NO.
20.
SCHEDULE OF SUPPLIES/SERVICES
21.
QUANTITY
22.
UNIT
23.
UNIT PRICE
24.
AMOUNT
See Schedule
(Use Reverse and/or Attach Additional Sheets as Necessary)
25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Govt. Use Only)
27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA ARE ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED
29. AWARD OF CONTRACT: REF. OFFER
DATED . YOUR OFFER ON SOLICITATION
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)
30b. NAME AND TITLE OF SIGNER (Type or Print) 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (Type or Print) 31c. DATE SIGNED
SEE SCHEDULE
7. FOR SOLICITATION
INFORMATION CALL:
SEE SCHEDULE
03:00 PM
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA - FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE ADDENDUM
EDWOSB
SPE60425R0405 Page 2 of 30
PJM 2025
SECTION A – STANDARD FORM (SF) 1449 ON PAGE 1
SECTION B – CONTINUATION BLOCK OF SF 1449
Questions regarding this solicitation must be submitted in writing via email to dlaenergy.eteam@dla.mil no later than 11 July 2025. The Government may not provide answers prior to the date and time provided on SF 1449, block 8.
CONTINUATION OF SF 1449, BLOCK 8 OFFER DUE DATE
This date refers only to the non-price proposal requirements of this Request for Proposal (RFP). Offerors are encouraged to submit their proposals early as pricing is not required prior to the date/time defined in SF 1449, Block 8. Offerors shall submit all Non-Price Proposal elements and all other required documents pursuant to this RFP. Refer to Attachment titled “Proposal Requirements PJM2025” for more information on proposal submission.
Prospective offeror’s are encouraged to review Federal Acquisition Regulation 15.208 regarding timely submission of offers. Specifically, please be aware that it is the offeror’s responsibility to ensure that their offer is received at the designated Government office prior to the solicitation closing. Submission of offers by electronic commerce (e.g. e-mail or fax) is governed by FAR 15.208(b)(1)(i). If an offeror electronically submits its offer on the day the solicitation closes, then timeliness will be determined based on whether or not the offer was actually received prior to closing. In that situation, the offeror will bear the risk of any delay in the transmission of their offer (e.g. offeror clicked “send” prior to the closing of the solicitation, but the e-mail did not arrive until after the time for closing), and offers not actually received prior to closing will be late. However, pursuant to FAR 15.208(b)(1)(i), if an offeror utilizes a means of electronic commerce to send their offer and transmits it not later than 5:00 p.m. ONE DAY PRIOR to the time for closing (and can prove that they have done so), then the offeror will be protected from such unexpected transmission delays and its offer will be considered timely.
*E-mails being sent to DLA Energy by non-DoD entities during the weekdays from 0800 to 1700 may be delayed up to several hours. To minimize potential issues as a result of any e-mail delays, DLA Energy requests that any correspondence from Non-DoD Entities allow at least 24 hours to be received.
The Government reserves the right not to consider any exceptions to the stated solicitation requirements received after the Offer Due Date.
B1.08 SUPPLIES TO BE FURNISHED (ELECTRICITY) (DLA ENERGY APR 2021)
(a) The contract quantities shown below are best estimates based on historical data only of the Government’s requirements for the contract period. The Contractor shall supply and deliver electricity and any ancillary services required in the STATEMENT OF WORK/SPECIFICATIONS (ELECTRICITY) contract text. Contract performance shall be accomplished in accordance with the terms and conditions of this contract.
(b) As used throughout this solicitation/contract, kW means kilowatt; kWh means kilowatt-hour; and UDC means Utility Distribution Company. Below are the acronyms and full names of each utility service area, public utility commission, the applicable NERC region, and those NERC Regions that border the applicable NERC Region.
RTO/ISO: PJM
Public Utility Commission (PUC):
Public Service Commission of the District of Columbia Maryland Public Service Commission mailto:dlaenergy.eteam@dla.mil
SPE60425R0405 Page 3 of 30
State of New Jersey Board of Public Utilities Pennsylvania Public Utility Commission Public Utility Commission of Ohio Illinois Commerce Commission
Utility Service Area:
AC Electric Atlantic City Electric AEP Ohio American Electric Power Ohio
AES AES Ohio BG&E Baltimore Gas and Electric ComEd Commonwealth Edison Delmarva Delmarva Power Duquesne Duquesne Light Company JCP&L Jersey Central Power and Light Met-Ed Metropolitan Edison Company PE Potomac Edison PECO Philadelphia Electric Power Company Penelec Pennsylvania Electric Company Penn Power Pennsylvania Power Company PEPCO Potomac Electric Power Company PPL Pennsylvania Power and Light PSE&G Public Service Enterprise Group UGI - Electric United Gas Improvement Company West Penn Power West Penn Power Company
(c) The Government is soliciting offers for supply and transmission of electricity and ancillary services for the following locations:
Table 1:
CLIN1 Location/Installation Name Total Accounts
Total Estimated Quantity2 (kWh)
0001 DIA (DC) 1 89,049,904
0002 Joint Base Henderson-Hall (McNair) 2 30,249,408 0003 Marine Barracks Washington 4 14,900,206 0004 Naval Research Lab (DC) 1 223,927,230 0005 US National Arboretum 9 2,557,710
0006 DISA 1 64,922,784
0007 Fort Meade 231 166,857,500 0008 Army Corps of Engineers 20 235,637,946
0009 CSSG 1 21,135,022
0010 DIA (MD) 1 5,006,112
0011 Naval Research Lab (MD) 1 18,276,132 0012 Maryland Procurement Office 26 1,492,571,242 0013 Fort Detrick - Forrest Glen 3 2,497,262 0014 National Agricultural Library (USDA) 1 9,370,876 0015 National Institutes of Health (NIH) 3 21,287,254 0016 Catoctin 4 22,630,586
SPE60425R0405 Page 4 of 30
0017 Fort Detrick 4 337,351,314
0018 Joint Base McGuire Dix Lakehurst
(JBMDL) 156 92,732,962
0019 NJ IDA 1 11,995,096
0020 DLA Columbus 1 103,184,960 0021 JSMC Lima 1 77,212,800 0022 Wright-Patterson Air Force Base 5 799,635,728 0023 Bettis Atomic Power Laboratory 1 103,947,360 0024 Carlisle Barracks 2 49,751,200 0025 DLA Susquehanna 2 67,971,126 0026 Tobyhanna 1 133,608,000 0027 Letterkenny Army Depot 75 61,019,334 0028 99th Army Reserve (MD) 9 6,830,844 0029 99th Army Reserve (NJ) 5 3,777,950 0030 99th Army Reserve (PA) 47 19,369,500 0031 99th Army Reserve PA - Duquesne 5 3,365,512 0032 99th Army Reserve PA - UGI 2 1,453,712
0033 PPPL 2 41,020,712
0034 Argonne National Laboratory 1 1,265,109,688
Total 629 5,600,214,972 1Contract Line Item Number (CLIN) 2This is the total estimated quantity for the entire 24-month delivery period. Quantities were derived from Attachment I – Installation Data Sheet PJM 2025, which illustrates 12 months of historical usage (and/or projected usage where applicable) for each account being solicited.
(d) The Government is soliciting offers for a 24-month period of performance from the meter read date occurring in the month of December 2025 to the meter read date occurring in the month of December 2027. Specifics for each line item are provided with each individual Installation Data Sheet.
The information includes: (1) Line Item Number, (2) Location, (3) Local Electric Utility, (4) Current Tariff Rate, (5) Utility Account Number; (6) Contract Performance Period, (7) Monthly Consumption and Demand Data; and (8) Interval Data. Please use the following link to access the information: SAM.Gov
(e) The Government is soliciting offers for Firm Fixed-Price (FFP), Requirements Type basis for electricity for CLINs 0001 through 0032. The Government is soliciting offers for Fixed Price Requirements Type utilizing Locational Marginal Pricing (LMP) for CLIN 0033 and CLIN 0034.
(1) CLINs 0001 through 0027 (Firm Fixed-Price):
(i) Prices shall include the following charges:
Energy, ancillary services, Auction Revenue Rights (ARR), PJM transmission losses, UDC losses, all costs attributed to meeting state Renewable Portfolio Standards (RPS), FERC Order 745, and independent system operator/regional transmission organization fees (all retail supply costs) to the service point as specified in this solicitation. Balancing Congestion Charges, existing Reserve Market Charges (and credits), and new or modified charges resulting from PJM’s reserve price formation and reserve market enhancements implementation shall be considered part of ancillary services and shall be included in the
SPE60425R0405 Page 5 of 30
Firm Fixed-Price for all CLINs.
(ii) The charges not included in the offered unit price are:
(A) Transmission including:
(1) Network Integration Transmission Service (NITS):
Shall be based on the account’s Network Transmission Service Obligation.
(2) Transmission Enhancement Charge (TEC):
PJM Billing Line Item 1108
(3) Regional Transmission Expansion Planning Process (RTEP):
PJM Billing Line Item 2108
(4) TES (Transmission Enhancement Settlement [EL05-121-009]):
PJM Billing Line Item 1115
(B) Reliability Must Run (RMR)
(C) Transmission Loss Credits
(D) Capacity:
The cost to secure capacity to comply with PJM capacity requirements shall be passed through to the Government. The daily capacity charge to the Government shall not exceed the product of the Contractor’s Daily Unforced Capacity Obligation on the account’s behalf and the PJM Final Zonal Net Load Price for Capacity. The PJM Final Zonal Net Load Price for Capacity is equal to the PJM Final Zonal Capacity Price minus the Final Zonal Capacity Transfer Rights Credit Rate. The Daily Unforced Capacity Obligation is equal to the Obligation Peak load multiplied by the Final Zonal Reliability Pricing Model (RPM) Scaling Factor times the Forecast Pool Requirement times the Daily Zonal Obligation Peak Load Scaling Factor, as those terms are defined by PJM, for the relevant time period and zone in which the account is located. Obligation Peak Load is also referred to as Peak Load Contribution (PLC) or Capacity PLC in certain UDC markets.
Obligation Peak Load (or Capacity PLC) is assigned to the account annually by the relevant UDC.
Formula:
Daily Capacity Charge ($) = Daily Unforced Capacity Obligation * Final Zonal Net Load Price for Capacity ($/MW-Day)
Daily Unforced Capacity Obligation = Annual Capacity PLC (MW) * Final Zonal RPM Scaling Factor * Forecast Pool Requirement * Daily Zonal Capacity Scaling Factor
Where:
Annual Capacity PLC (MW) is the capacity tag assigned to each account by the UDC for each PJM delivery year (June 1st through May 31st).
Final Zonal RPM Scaling Factor, Forecast Pool Requirement, Daily Zonal Capacity Scaling Factors, and Final Zonal Capacity Prices are as published on PJM’s website.
(2) CLINs 0028 through 0032 (Firm Fixed-Price):
(i) Prices shall include the following charges:
All retail supply costs to the point of receipt as specified in this solicitation; and include any Gross Receipts, Franchise, or Graft taxes for which the Government is not exempt.
(ii) The charges not included in the offered unit price are:
Sales tax, property tax, or New Jersey Sales and Use Tax.
(3) CLINs 0033 and 0034 (LMP): See B802 for CLIN 0033 PPPL and CLIN 0034 Argonne.
SPE60425R0405 Page 6 of 30
NOTE 1: The following anticipated load requirements and changes are expected:
0004 - Naval Research Lab (DC) - Anticipated completion of a 4.5 MW cogeneration plant to be operational in July 2026, contingent upon approved Pepco Interconnection Agreement and separate switchgear replacement.
0012 - MPO - For the largest BG&E account only, CLIN 0012 began requiring additional usage in January 2025 with usage (in kWh) increasing by an amount approximately equal to 9.2% of the 12-month quantity (in kWh) listed in the installation data sheet for the largest BG&E account.
0014 - National Agricultural Library (USDA) - Anticipated completion of a repair and maintenance contract FY2025 – FY2027 which includes several AHU replacements and other building improvements that would increase energy efficiency.
0018 - Joint Base McGuire Dix Lakehurst (JBMDL) - Smart controls have come online between March 2024 and May 2025 and are expected to reduce consumption by about 15% or more. A total of 27 accounts impacted by smart controls are identified in Installation Data Sheet CLIN 0018 JBMDL.
0019 - NJ IDA - IDA CCRP may undergo a construction project to build an addition with a completion date in December 2026, which impact not greater than 10%.
0024 - Carlisle Barracks - Reduction of usage by approximately 200,000 kwh due to the demolition of 3 buildings on the installation.
0025 - DLA Susquehanna - PV solar is underway, anticipated completion at the end of 2025. Conversion of UDC from old material handling system to a new one may have a minor impact. Building 89 will go off natural gas and switch to heat pumps, anticipated June 2026.
0027 - Letterkenny Army Depot - As part of the Base Realignment and Closure Act (BRAC95) of 1995, approximately 1200 acres and various facilities, including utilities located within the Letterkenny Army Depot were determined to be excess property. The realignment directive required that the Depot’s water system, wastewater system, electric distribution system (EDS) and short-line railroad be transitioned to the Local Reuse Authority (LRA). The LRA is the Letterkenny Industrial Development Authority (LIDA). LIDA assumed operational control of the EDS in May 1999, with routine operations and management provided by West Penn Power Company, now part of First Energy Pennsylvania Electric Company. Since acquiring the EDS, LIDA has been responsible for securing system-wide power generation contracts to serve the Letterkenny Army Depot. The water system, wastewater system and short-line railroad assets were sold in 2022. In August 2023, LIDA entered into an Asset Purchase Agreement to sell the EDS to First Energy Pennsylvania Electric Company, a Pennsylvania jurisdictional utility. The acquisition, which has been approved by the Pennsylvania Public Utility Commission, is scheduled to be close in December 2025, marking the strategic exit of LIDA’s utility services prescribed under BRAC95.
0033 – PPPL - Due to new construction and experiments coming online, total usage is projected to increase from approximately 20,000 MwH in FY24 to greater than 30,000 MwH by FY27.
0034 - Argonne National Laboratory - The load profile is expected to vary as our supercomputer (demand as high as 57,000 kW) and data center loads fluctuate based on our customers’ requirements. Computer demand is accounted for in projected usage estimates provided in Attachment I - Installation Data Sheet PJM 2025. The Government will use its best efforts to notify Contractor of any substantial deviation in usage to the extent practicable.
SPE60425R0405 Page 7 of 30
B802 LOCATIONAL MARGINAL PRICE (ELECTRICITY) (DLA ENERGY) (JAN 2009)
**Applicable ONLY to CLINS 0033 PPPL and 0034 Argonne**
The total amount charged by the Contractor (for accounts listed in Attachment I - Installation Data Sheet PJM 2025) each month shall equal the sum of the following components, consisting of a Transaction Fee that is fixed and therefore not subject to true-up or pass-through, an Energy charge that represents a pass-through of actual energy market charges as set forth below, and various other market charges as set forth and described below that shall provide for pass-through of various cost elements or credits at cost:
(a) ENERGY.
(1) CLIN 0033 PPPL: For each hour of the month, the Government shall pay the Contractor the product of the Day-ahead LMP for the PJM Residual Metered Load Aggregate Load Zone through which the account is served and the metered load of the account adjusted for line losses to the Government’s meter.
(2) CLIN 0034 Argonne: For each hour of the month, the Government shall pay the Contractor the product of the Day-ahead LMP for the PJM Residual Metered Load Aggregate Load Zone through which the account is served and the metered load of the account. Metered load should not be grossed up for line losses. Defined peak and off-peak hours are based on ComEd’s definition of Retail Peak Period and Retail Off-Peak Period in its terms and conditions. Retail Peak Period is defined as 6AM to 10PM, Monday through Friday, except on days designated as holidays by the NERC. Retail Off-Peak Period is defined as all hours other than those included in the Retail Peak Period. These definitions will remain in effect during the term of this contract.
(b) TRANSACTION FEE. The Government shall pay the Contractor the product of a fixed transaction fee ($/kWh) multiplied by the account’s total metered energy consumption in that month.
Payment of this Transaction Fee shall compensate the Contractor for all services performed and all costs incurred to supply electricity to the point of delivery whose recovery is not explicitly provided for by the separate Energy and Other Market Charges components described in subsections (a) and (c) of this section. The price of the fixed fee shall remain constant throughout the term of the contract.
NOTE 1: RPS for CLIN 0034 Argonne is not included in the transaction fee as Illinois UDCs cover the RPS requirement.
(c) OTHER MARKET CHARGES. The charges and credits listed below shall be passed through to the Government with no mark-ups.
(1) Applicable ONLY to CLIN 0033 PPPL
(i) CAPACITY. Capacity Costs – The cost to secure capacity to comply with PJM capacity requirements shall be passed through to the Government. The daily capacity charge to the Government shall not exceed the product of the Contractor’s Daily Unforced Capacity Obligation on the account’s behalf and the PJM Final Zonal Net Load Price for Capacity. The PJM Final Zonal Net Load Price for Capacity is equal to the PJM Final Zonal Capacity Price minus the Final Zonal Capacity Transfer Rights Credit Rate. The Daily Unforced Capacity Obligation is equal to the Obligation Peak load multiplied by the Final Zonal Reliability Pricing Model (RPM) Scaling Factor times the Forecast Pool Requirement times the Daily Zonal Obligation Peak Load Scaling Factor, as those terms are defined by PJM, for the relevant time period and zone in which the account is located. Obligation Peak Load is also referred to as Peak Load Contribution (PLC) or Capacity PLC in certain UDC markets. Obligation Peak Load (or Capacity PLC) is assigned to the account annually by the relevant UDC.
SPE60425R0405 Page 8 of 30
Daily Capacity Charge ($) = Daily Unforced Capacity Obligation * Final Zonal Net Load Price for Capacity ($/MW-Day)
Annual Capacity PLC (MW) is the capacity tag assigned to each account by the EDC for
Final Zonal RPM Scaling Factor, Forecast Pool Requirement, Daily Zonal Capacity Scaling Factors, and Final Zonal Capacity Prices are as published on PJM’s website.
PJM capacity price, scaling factors, pooling requirements, and Argonne PLC subject to change each June
1. Monthly costs should be prorated when costs change during a mid-month billing cycle.
(ii) TRANSMISSION. Network Integrated Transmission Service (NITS) shall be based on the account’s Network Transmission Service Obligation and be a direct pass-through to the Government. PJM’s Transmission Enhancement Charge (TEC) Billing Line Item 1108, Transmission Enhancement Credits Billing Line Item 2108, Transmission Enhancement Settlement (EL05-121-009) Charges (PJM Billing Line Item Number 1115), and Regional Transmission Expansion Planning Process (RTEP) charges shall be treated as a direct pass-through to the Government.
(iii) TRANSMISSION AND DISTRIBUTION LOSSES. The Contractor shall refund to (or charge) the PJM marginal loss credit (PJM Transmission Loss Credit). NOTE: For purposes of calculating energy charges, applicable transmission and distribution losses are a pass through. Contractor shall use the utility-defined line loss factor applicable to the respective rate class(s) for each individual account(s), as set forth in the state-approved distribution tariff of the applicable utility for each account.
PJM Marginal Loss Credit (PJM Transmission Loss Credit) should be charged as PJM Line Item #2220.
(iv) RELIABILITY MUST RUN (RMR) CHARGES The Contractor shall treat RMR Charges as a direct pass through with no mark up.
(v) AUCTION REVENUE RIGHTS (ARRS) shall be passed through to the Government.
(2) Applicable ONLY to CLIN 0034 Argonne
(i) CAPACITY. Capacity Costs – The cost to secure capacity to comply with PJM capacity requirements shall be passed through to the Government. The daily capacity charge to the Government shall not exceed the product of the Contractor’s Daily Unforced Capacity Obligation on the account’s behalf and the PJM Final Zonal Net Load Price for Capacity. The PJM Final Zonal Net Load Price for Capacity is equal to the PJM Final Zonal Capacity Price minus the Final Zonal Capacity Transfer Rights Credit Rate. The Daily Unforced Capacity Obligation is equal to the Obligation Peak load multiplied by the Final Zonal Reliability Pricing Model (RPM) Scaling Factor times the Forecast Pool Requirement times the Daily Zonal Obligation Peak Load Scaling Factor, as those terms are defined by PJM, for the relevant time period and zone in which the account is located. Obligation Peak Load is also referred to as Peak Load Contribution (PLC) or Capacity PLC in certain UDC markets. Obligation Peak Load (or Capacity PLC) is assigned to the account annually by the relevant UDC.
Formula Based on June 1, 2025 Values:
Argonne’s Capacity PLC MW 68.7858 MW x Zonal Scaling Factor Adjustment FPR Pool 1.02233 Pooling Requirement Adjustment x 0.9389 Capacity MW: = 66.009 MW
SPE60425R0405 Page 9 of 30
June 1, 2025 PJM Auction Price : Daily $270.53 per MW day = Capacity Cost: $17,850.81 per day
Daily Capacity Charge ($) = Daily Unforced Capacity Obligation * Final Zonal Net Load Price for Capacity ($/MW-Day)
Annual Capacity PLC (MW) is the capacity tag assigned to each account by the UDC for
Final Zonal RPM Scaling Factor, Forecast Pool Requirement, Daily Zonal Capacity Scaling Factors, and Final Zonal Capacity Prices are as published on PJM’s website.
PJM capacity price, scaling factors, pooling requirements, and Argonne PLC subject to change each June
1. Monthly costs should be prorated when costs change during a mid-month billing cycle.
(ii) TRANSMISSION. Direct pass-through of only PJM Network Integration Transmission Service Rate (“NITS”) for Commonwealth Edison Company based on Argonne’s Network Service PLC. All other transmission related costs, including enhancement charges, must be included in the Transaction Fee.
Current Cost: 73.3820MW x $38,531.00 per MW per year ÷ 365 = $7,746,53 per day.
Formula: Daily NITS Charge ($) = Annual NSPL Tag (MW) * Daily Zonal NSPL Scaling Factor * Daily Zonal NITS Rate ($/MW-day)
Where:
Annual NSPL tag is the transmission tag assigned to each account by the UDC for each calendar year.
Daily Zonal NITS Rate = Annual Zonal NITS Rate (as published on PJM’s website) divided by the number of days in the year.
Daily Zonal NSPL Scaling Factors are as published on PJM’s website.
PJM NITS subject to change each June 1 and Argonne’s PLC subject to change each January 1.
Invoice costs should be prorated when costs change during a billing cycle.
Monthly invoice price should be pro-rated if transmission rate or ANL PLC changes during a billing period.
(iii) DISTRIBUTION AND TRANSMISSION LOSSES. Direct pass-through of losses.
Losses are to appear as an additional line item on the invoice submitted to Argonne. ComEd’s 2023 - 2025 tariff (ILL. C. C. No 10) distribution loss (“DLF)” and transmission loss (“TLF”) factors are 0.68% and 1.60%, respectively. The combined loss factor is 2.29% [(1 + 0.0068) x (1 + 0.0160) = 1.0229].
SPE60425R0405 Page 10 of 30
All other loss related cost components must be included in the Transaction Fee. This includes ComEd’s Unaccounted For Energy (“UFE”) and PJM’s loss deration.
Formula: 2.29% x ComEd metered kWh x weighted average Commodity Price in the billing period. The Commodity Price shall be consistent with the energy price defined in B802, Subparagraph (a)(2).
(iv) DIRECT PASS-THROUGH RELIABILITY MUST RUN. Direct pass-through of these charges only if they apply to the ComEd zone.
(d) INDICES. In the event that the PJM LMP or any other index upon which any energy price for this contract is determined ceases to publish or is substantially altered in derivation or application (including, but not limited to, the elimination of price caps), the parties shall agree upon a substitute index. If the parties fail to agree on an appropriate substitute index, the matter shall be resolved in accordance with paragraph (d), Disputes, of the CONTRACT TERMS AND CONDITIONS – COMMERCIAL ITEMS clause of the contract.
B806 CONTRACT PRICE CONVERSION (ELECTRICITY) (DLA ENERGY) (JAN 2012)
**Applicable ONLY to CLINS 0033 PPPL and 0034 Argonne**
(a) At any time during contract performance, the Government and the Contractor can mutually agree to convert any LMP-based contract line items quantity to a firm-fixed price for a specific delivery month(s) or for the remainder of the delivery period, based on the historical usage identified in the Installation Data Sheets. Either party can initiate such a proposal for a specific delivery month(s) or for the remaining contract period. The conversion proposal must identify the contract line item(s) for which conversion is proposed and specify a period for acceptance in LOCAL TIME, FORT BELVOIR, VIRGINIA.
(b) Price negotiations may be held. If the Government accepts a proposal, the contract will be modified to reflect the revised price(s). Acceptance by the Government of the Contractor’s price proposal within the time limit allotted by the Contractor for acceptance of the price proposal shall be binding.
C800 STATEMENT OF WORK/SPECIFICATIONS (ELECTRICITY) (DLA ENERGY) (JAN
2012)
(a) STATEMENT OF WORK. The Contractor shall supply electricity and any ancillary services required to deliver electricity to the point of delivery and for the scheduling and coordination of the delivery of electricity to the service point for each account under the contract. All quantities ordered by the Government shall be considered firm for delivery by the Contractor to the delivery point, and for scheduling and coordinating, for ultimate delivery to the service point for each account. Charges incurred as a result of the Contractor's failure to abide by the terms of the applicable Retail Access rules and/or the UDC Service Agreement shall be the responsibility of the Contractor. With the exception of any and all transmission and distribution related charges payable by the Government to the UDC under the applicable tariff for each account (unless said charges are the result of the Contractor's failure to perform in accordance with the contract), the Contractor is responsible for all costs associated with deliveries to the delivery point and the scheduling and coordination for delivery of electricity to the service point for each account under the contract. The Contractor shall be liable for any and all penalties and/or additional costs assessed to the Government for the nondelivery of the firm requirements in accordance with paragraphs
(f) and (m) of the FAR 52.212-4 CONTRACT TERMS AND CONDITIONS – COMMERCIAL ITEMS clause.
NOTE: The point of delivery does not equal service point and the responsibility of the Contractor is to the delivery point.
(b) INVOICE AND PAYMENT.
SPE60425R0405 Page 11 of 30
The contractor must submit all invoice information to the appropriate UDC under the terms of the applicable Retail Access Rule, in accordance with terms of its UDC Service Agreement. All invoicing shall be based on metered quantities at the service point for each account. The contractor may only invoice for charges allowed under the terms and conditions of the contract. Any costs associated with invoicing, to include Consolidated Billing, shall be the responsibility of the Contractor and shall be included as part of the offered price.
The Government will utilize Consolidated UDC Billing for the following CLINS:
0001 DIA (DC)
0002 Joint Base Henderson-Hall (McNair) 0005 US National Arboretum
0009 CSSG
0010 DIA (MD)
0013 Fort Detrick - Forrest Glen 0015 National Institutes of Health (NIH) 0017 Fort Detrick
0019 NJ IDA
0020 DLA Columbus 0021 JSMC Lima 0024 Carlisle Barracks 0028 99th Army Reserve (MD) 0029 99th Army Reserve (NJ) 0030 99th Army Reserve (PA) 0031 99th Army Reserve PA - Duquesne 0032 99th Army Reserve PA – UGI
The Government will utilize Dual Billing for the following CLINS:
0003 Marine Barracks Washington 0004 Naval Research Lab (DC)
0006 DISA
0007 Fort Meade 0008 Army Corps of Engineers 0011 Naval Research Lab (MD) 0012 Maryland Procurement Office 0014 National Agricultural Library (USDA) 0016 Catoctin 0018 Joint Base McGuire Dix Lakehurst (JBMDL) 0022 Wright-Patterson Air Force Base 0023 Bettis 0025 DLA Susquehanna 0026 Tobyhanna 0027 Letterkenny Army Depot
0033 PPPL
0034 Argonne National Laboratory
The Government will not pay any additional charges for billing services. Each invoice shall be prepared in a manner consistent with and shall conform to the applicable PUC requirements for Dual Billing.
In addition to the requirements set forth in FAR 52.212-4 CONTRACT TERMS AND CONDITIONS - COMMERCIAL ITEMS Paragraph (g), each contractor invoice shall include the following information, if available from the UDC:
(1) Installation name, Line Item, and individual account information (Account
SPE60425R0405 Page 12 of 30
Number, Meter Number, and Service Address).
(2) The invoice shall also include the Supplier’s information such as logo, address, point of contact (name and phone number), and wiring information.
(3) Billing period for each account.
(4) Total consumption for each account.
(5) Total Energy Charge (broken down by energy charges and demand charges, if available).
(6) Charges for services broken out in detail for each account in a manner consistent with the terms and conditions of the contract and the applicable PUC requirements.
(7) All information required by the applicable PUC to be included on customer invoice.
(8) If customer questions information on an invoice, supporting documentation is required before payment will be made.
(9) If a supplier is unable to issue a bill based on actual meter reading due to the failure of the transmission and distribution utility, municipally owned utility or electric cooperative to obtain or transmit a meter reading to the supplier, the supplier may issue a bill based on an estimated reading for the affected account. The supplier must inform the customer of the reason for the issuance of the estimated bill, and the Government reserves the right to obtain documentation relating to the efforts taken by the supplier to obtain the meter read data. For estimated billing purposes, the supplier shall use the relevant monthly consumption data (as the estimate) included in the applicable Installation Data Sheet. All estimated bills shall be trued up on the next billing cycle if the applicable information is received by then.
(10) Supplier coordination with the local utility will be necessary to ensure that these customers receive identical billing data from both the supplier and the local utility (i.e.
commodity and wire charges must be based on the utility’s billing cycle).
(11) Applicable to Line Item 0012 MPO Only: All information listed in attachment V – MPO Invoice Instructions.
(12) Applicable to Line Item 0018 JBMDL Only: For all the supplier charges on CLIN 0018 JBMDL, the Contractor shall provide a single supplier invoice for all accounts serviced which includes the following billing details, at a minimum, for each account: the billing period, service address, UDC#, JCPL Meter #, kW ICAP, kW Trans, kWh Consumption, Current Total Actual Charges, and all applicable pass-through items. In addition, a single excel spreadsheet will be submitted that contains the invoice information by LDC account.
(13) For all Pennsylvania Line Items, the PA Gross Receipts Tax (GRT) shall not be included in the offered unit prices. It shall be billed as a separate line item as a direct pass- though.
(14) Applicable to Line Item 0034 Argonne National Laboratory Only: All information listed in Attachment VI – Argonne Invoice Format.
NOTE 1: The paying offices for each installation awarded under any resultant contract will be identified below, after contract award.
CLIN Installation Billing Type WAWF Instruction
0001 DIA (DC) UDC
Consolidated
Supplier submit energy charges to UDC.
0002 Joint Base Henderson-Hall (McNair) Dual Address & POC will be provided on contract.
SPE60425R0405 Page 13 of 30
0003 Marine Barracks Washington Dual Yes Use DFARS 252.232-7006 WAWF Instruction
0004 Naval Research Lab (DC) Dual Yes Use DFARS 252.232-7006 WAWF Instruction
0005 US National Arboretum UDC
0006 DISA Dual Address & POC will be provided on contract.
0007 Fort Meade Dual Address & POC will be provided on contract.
0008 Army Corps of Engineers Dual Address & POC will be provided on contract.
0009 CSSG UDC
0010 DIA (MD) UDC
0011 Naval Research Lab (MD) Dual Yes Use DFARS 252.232-7006 WAWF Instruction
0012 Maryland Procurement Office Dual Address & POC will be provided on contract.
0013 Fort Detrick - Forrest Glen Dual Address & POC will be provided on contract.
0014 National Agricultural Library (USDA) Dual Address & POC will be provided on contract.
0015 National Institutes of Health (NIH) UDC
0016 Catoctin Dual Address & POC will be provided on contract.
0017 Fort Detrick Dual Address & POC will be provided on contract.
0018 Joint Base McGuire Dix Lakehurst (JBMDL) Dual Yes Use DFARS 252.232-7006 WAWF
Instruction
0019 NJ IDA UDC
0020 DLA Columbus UDC
0021 JSMC Lima UDC
0022 Wright-Patterson Air Force Base Dual Address & POC will be provided on contract.
0023 Bettis Dual Address & POC will be provided on contract.
0024 Carlisle Barracks UDC
0025 DLA Susquehanna Dual Address & POC will be provided on contract.
0026 Tobyhanna Dual Yes Use DFARS 252.232-7006 WAWF Instruction
0027 Letterkenny Army Depot Dual Address & POC will be provided on contract.
0028 99th Army Reserve (MD) UDC
SPE60425R0405 Page 14 of 30
0029 99th Army Reserve (NJ) UDC Consolidated Supplier submit energy charges to UDC.
0030 99th Army Reserve (PA) UDC Consolidated Supplier submit energy charges to UDC.
0031 99th Army Reserve PA - Duquesne UDC Consolidated Supplier submit energy charges to UDC.
0032 99th Army Reserve PA - UGI UDC Consolidated Supplier submit energy charges to UDC.
0033 PPPL Dual Address & POC will be provided on contract.
0034 Argonne National Laboratory Dual Address & POC will be provided on contract.
(c) METERING AND METER READING SERVICES. Will be provided by the incumbent UDC for each account.
(d) SCHEDULING AND SUPPLY MANAGEMENT. It shall be the Contractor's responsibility to schedule deliveries for all accounts awarded for the time period specified herein. The Contractor shall be responsible for supply management and overall coordination of production, transmission, and distribution of electrical power to the service point of each account identified in the contract. As such, the Contractor shall be knowledgeable of and responsible for imbalance policies, transmission grid losses, transmission congestion charges and UDC line losses for the delivery of electricity to the service point of each account under the contract. The Contractor must meet all applicable State and Federal requirements necessary to successfully complete any contract. The Government will not pay any costs associated with the Contractor's failure to deliver electrical power at the delivery point sufficient to meet the demand at the service point of each account under the contract or to schedule and coordinate for the delivery of electricity to each service point.
(e) RECORD KEEPING. The Contractor shall keep records of data required to bill in accordance with the utility tariff of each account (demand and consumption data) in an electronic database format compatible with Microsoft Access or a spreadsheet format compatible with Microsoft Excel. These records shall be made available to DLA Energy or to any party designated by DLA Energy as authorized to request this data. In the event that the Contractor maintains records on demand and consumption data in addition to that required to bill in accordance with the utility tariff, said data shall also be made available to DLA Energy or to any party designated by DLA Energy as authorized to request this data.
The Contractor shall provide (or make available) to DLA Energy or to any party designated by DLA Energy, interval data (for those accounts with an interval meter) in Microsoft Excel format, on a monthly basis throughout the entire delivery term of any resultant contract.
(f) ORDERING. For the purposes of this contract, the instantaneous load at the service point, as described in the individual Installation Data Sheet, shall constitute an order for electricity to be furnished under this contract.
(g) POINT OF DELIVERY. For this solicitation and any resulting contract, the delivery point for each account is defined as an interconnect with the UDC owned or controlled transmission or distribution systems.
(h) SERVICE POINT. For this solicitation and any resulting contract, the service point is defined as the meter(s) indicated for each account awarded as described in Attachment I - Installation Data Sheet
PJM 2024.
(i) SPECIFICATIONS. The electricity provided under this contract shall conform to the tariff of the transmitting and/or distributing utility at the delivery point(s) specified in the Schedule.
(j) ADDING FUTURE ACCOUNTS. It is possible that additional accounts not included in the solicitation may be added to the resultant contract(s). In that event, the Government will provide the Contractor with the facility’s electric requirement (if available) and the two parties shall enter into good faith negotiations to determine a price. A bilateral modification will be executed adding the line item on the Standard Form 30, Amendment of Solicitation/Modification of Award.
SPE60425R0405 Page 15 of 30
CONTRACT ADMINISTRATION
The following Government personnel are the administrative points of contact:
Point of Contact(s) will be provided upon contract award.
Point of Contact Role Email
H800 NOTIFICATION OF TARIFF/RATE CHANGES (ELECTRICITY) (DLA ENERGY FEB
2013) The Contractor shall use commercially reasonable efforts to provide the Contracting Officer with written notice received by the Contractor of any relevant changes to the transportation tariff/rate or the scheduling of a tariff/rate hearing that would reasonably be expected to have impact on the installations within a commercially acceptable time frame. Failure of the Contractor to comply with this contract text shall not be grounds for termination for cause.
NOTE: E-mail notification is acceptable, provided it includes the specific tariff change (via cut and paste) and its effective date.
I820 ELECTRICITY REGULATORY CHANGES (DLA ENERGY DECEMBER 2014)
(a) The contract price includes all applicable independent system operator/regional transmission organization (ISO/RTO/PUC) charges expected to be in effect and applicable to this contract at Government price acceptance.
(b) "After-imposed (ISO/RTO/PUC) charges," as used in this contract text, means any new or modified regulatory (ISO/RTO/PUC) charges not in effect or not applicable to transactions under this contract on the date the Government accepts pricing, but which are now in effect or applicable as the result of legislative, judicial, or administrative action, with the result that the Contractor is now required to pay or bear the charges. The contract price shall be increased by the amount of any after-imposed (ISO/RTO/PUC) charge (with no markup), provided the Contractor warrants in writing within 60 calendar days of the regulation change, that no amount for such after-imposed (ISO/RTO/PUC) charge was included in the contract price, as a contingency reserve or otherwise. The contractor shall provide such evidence as the Government may require in support of a request for adjustment resulting from any after-imposed (ISO/RTO/PUC) charge.
(c) "After-relieved (ISO/RTO/PUC) charges," as used in this contract text, means any amount of regulatory (ISO/RTO/PUC) charges that would otherwise have been payable on the transactions or property covered by this contract but which as the result of legislative, judicial or administrative action taking effect after the contract date the Contractor is not required to pay or bear, or for which the Contractor obtains a refund or drawback. The contract price shall be decreased by the amount of any after-relieved (ISO/RTO/PUC) charges.
(d) “Modified” means an unforeseeable change in law (or equivalent regulatory restructure) which occurs after contract award and results in increased regulatory (ISO/RTO/PUC) charges, the effects of which could not have reasonably been anticipated by the contractor prior to award.
(e) The Contractor shall notify the contracting officer of any after-imposed or after-relieved (ISO/RTO/PUC) charge within a commercially acceptable time frame and if seeking a price increase, simultaneously submit a proper claim for equitable adjustment. Price adjustments shall be accomplished via written modification to the contract.
NOTE 1: ISO/RTO/PUC is defined to include the applicable Independent System Operator, Regional Transmission Operator, Public Utility Commission, or any Governmental or regulatory entity with the authority to impose charges to which an account supplied under this contract is subject.
SPE60425R0405 Page 16 of 30
SECTION C – CONTRACT CLAUSES
(a) This solicitation incorporates clauses in full text, as identified below.
(b) This solicitation also incorporates clauses by reference, as identified below from Subpart 12.3 and Subpart 212.3, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.
(c) Alternatively, the full text of any FAR, DFARS, or DLAD provision may be accessed electronically at these addresses:
• eCFR :: 48 CFR Chapter 1 -- Federal Acquisition Regulation (FAR)
• DPCAP | Defense Acquisition Regulations System | DFARS/PGI
• DLA Acquisition (J7) Policy and Directives
CLAUSES INCORPORATED BY REFERENCE
Regulatory Number Clause Title FAR 52.204-13 System for Award Management Maintenance (OCT 2018) FAR 52.204-18 Commercial and Government Entity Code Maintenance (AUG 2020) FAR 52.204-21 Basic Safeguarding of Covered Contractor Information Systems (NOV 2021) DFARS 252.203-7000 Requirements Relating to Compensation of Former DoD Officials (SEP 2011) DFARS 252.203-7002 Requirements to Inform Employees of Whistleblower Rights (DEC 2022) DFARS 252.203-7003 Agency Office of the Inspector General (AUG 2019)
DFARS 252.204-7012 Safeguarding Covered Defense Information and Cyber Incident Reporting
(MAY 2024)
DFARS 252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support (JAN 2023)
DFARS 252.204-7018 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services (JAN 2023)
DFARS 252.204-7020 NIST SP 800-171 DoD Assessment Requirements (NOV 2023) DFARS 252.205-7000 Provision of Information to Cooperative Agreement Holders (OCT 2024) DFARS 252.216-7010 Postaward Debriefings for Task Orders and Delivery Orders (DEC 2022) DFARS 252.219-7003 Small Business Subcontracting Plan (DoD Contracts) – Basic (DEC 2019) DFARS 252.223-7008 Prohibition of Hexavalent Chromium (JAN 2023) DFARS 252.225-7001 Buy American and Balance of Payments Program (FEB 2024) DFARS 252.225-7012 Preference for Certain Domestic Commodities (APR 2022) DFARS 252.225-7021 Trade Agreements – Basic (FEB 2024)
DFARS 252.225-7052 Restriction on the Acquisition of Certain Magnets, Tantalum, and Tungsten
(MAY 2024)
DFARS 252.225-7056 Prohibition Regarding Business Operations with the Maduro Regime (JAN 2023)
DFARS 252.226-7001 Utilization of Indian Organizations, Indian-Owned Economic Enterprises, and Native Hawaiian Small Business Concerns (JAN 2023)
DFARS 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports (DEC 2018)
DFARS 252.232-7010 Levies on Contract Payments (DEC 2006) DFARS 252.243-7002 Requests for Equitable Adjustment (DEC 2022) DFARS 252.244-7000 Subcontracts for Commercial Products and Commercial Services (NOV 2023) DFARS 252.247-7023 Transportation of Supplies by Sea – Basic (OCT 2024) https://www.ecfr.gov/current/title-48/chapter-1 https://www.acq.osd.mil/dpap/dars/dfarspgi/current/index.html http://www.dla.mil/HQ/Acquisition/Offers/DLAD.aspx
SPE60425R0405 Page 17 of 30
FAR 52.212-4 CONTRACT TERMS AND CONDITIONS – COMMERCIAL ITEMS
(ELECTRICITY) (TAILORED) (OCT 2018)
NOTE: INSTRUCTIONS HAVE BEEN TAILORED TO BE MORE CONSISTENT WITH
COMMERCIAL PRACTICE UNDER FAR PART 52.212-4. ALL OTHER INSTRUCTIONS
INCLUDED IN FAR 52.212-4 ARE HEREBY INCORPORATED BY REFERENCE (SEE BLOCK 27A
OF STANDARD FORM 1449).
(f) EXCUSABLE DELAYS [TAILORED]. The Contractor shall be liable for default unless nonperformance is caused by an occurrence beyond the reasonable control of the Contractor and without its fault or negligence, such as acts of God or the public enemy, fires, floods, epidemics, quarantine restrictions, strikes, unusually severe weather, civil disturbance, hostile forces, terrorist acts or transmission failure. An excusable delay or similar event suffered by an independent service operator (PJM) (or an equivalent of an ISO) or a utility distribution company (or electric distribution company or transmission distribution services provider) shall constitute an excusable delay hereunder. The Contractor shall notify the Contracting Officer in writing as soon as it is reasonably possible after the commencement of any excusable delay, setting forth the full particulars in connection therewith, shall remedy such occurrence with all reasonable dispatch, and shall promptly provide notice to the Contracting Officer of the cessation of such occurrence. Upon delivery of notice of the occurrence of an excusable delay, the obligations of the Contractor shall be suspended to the extent affected by such excusable delay.
(k) TAXES [TAILORED].
(1) The contract price includes all applicable Federal, State, and local taxes and duties in effect at contract signing. Invoice requirements are expressed in Section B and C. If awarded, a copy of the state(s) sales tax exemption will be distributed (as needed).
(2) After-imposed Federal, State, or local tax, as used in this DLA Energy FAR Tailored clause, means any new or increased Federal, State, or local excise tax or duty, or tax that was exempted or excluded on the contract award date but whose exemption was later revoked or reduced, or whose computation was later changed during the contract period, on the transactions or property covered by this contract that the Contractor is required to pay or bear as the result of legislative, judicial, or administrative action taking effect after the contract date. It does not include social security tax, income tax, or other employment taxes. The contract price shall be increased by the amount of any after-imposed Federal, State or local tax, provided the Contractor warrants, in writing, that no amount for such newly imposed Federal, State, or local excise tax or duty or rate increase was included in the contract price, as a contingency reserve or otherwise.
(3) After-relieved Federal, State, or local tax, as used in this DLA Energy FAR Tailored clause, means any amount of Federal, State, or local excise tax or duty that would otherwise have been payable on the transactions or property covered by this contract, but which the Contractor is not required to pay or bear, or for which the Contractor obtains a refund or drawback, as the result of legislative, judicial, or administrative action taking effect after the contract date. It does not include social security tax, income tax, or other employment taxes. The contract price shall be decreased by the amount of any after-relieved Federal, State, or local tax.
(l) TERMINATION FOR THE GOVERNMENT'S CONVENIENCE [TAILORED].
(1) In accordance with…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .