SOW Pinecastle B149 HVAC Repl Sketch.pdf

PDF 48 KB Posted

Attached to
Pinecastle HVAC replacement
Solicitation number
N6945020R0120
Issued by

About this file

This document includes a statement of work sketch and related federal contract opportunity solicitation. The statement of work sketch outlines the replacement of HVAC systems at Building 149 at Pinecastle, including removing three existing air conditioning units and installing a new 3-ton CRAC modular indoor unit and outdoor unit. The sketch shows the proposed routing of refrigerant lines above doorways and condensate drain lines, along with routing of electrical circuits and conduits around the exterior of the building between 9 to 10 feet above grade. The related solicitation is from the Department of the Navy Naval Facilities Engineering Command for the Pinecastle HVAC replacement. The contractor shall provide all labor, materials, equipment, transportation and supervision necessary to replace the HVAC systems and install the new CRAC unit as outlined in the statement of work sketch. The solicitation number is N6945020R0120.

View the file

Other files

File Type Posted
AMD 02 RFP N6945020R0120.pdf PDF
AMD 01 RFP N6945020R0120.pdf PDF
Price Proposal spreadsheet.xls XLS spreadsheet
Pinecastle B149 HVAC Repl SOW .docx DOCX document
PRE-PROPOSAL INQUIRY FORM.xlsx XLSX spreadsheet
RFP N6945020R0120.pdf PDF
SOW Pinecastle B149-L HVAC Pics.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

gerald.holcomb Text Box Electrical Panel (Labeled 16) gerald.holcomb Text Box A/C gerald.holcomb Text Box A/C gerald.holcomb Rectangle gerald.holcomb Text Box A/C gerald.holcomb Text Box gerald.holcomb Rectangle gerald.holcomb Text Box New (CRAC) Modular Indoor Unit gerald.holcomb Line gerald.holcomb Text Box New (CRAC) Outdoor Unit gerald.holcomb Line gerald.holcomb Text Box Proposed Routing Of Refrigerant Lines (Above Doorways) gerald.holcomb Line gerald.holcomb Pencil gerald.holcomb Line gerald.holcomb Text Box gerald.holcomb Text Box Proposed Routing Of Condensate Drain Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Rectangle gerald.holcomb Rectangle gerald.holcomb Rectangle gerald.holcomb Rectangle gerald.holcomb Text Box Routing Of Electrical Circuits/Conduits gerald.holcomb Line gerald.holcomb Line gerald.holcomb Text Box Routing Of Electrical Circuits/Conduits (9' to 10' Above Grade) Around Exterior Perimeter Of Bldg.

gerald.holcomb Line gerald.holcomb Line gerald.holcomb Rectangle gerald.holcomb Line gerald.holcomb Line gerald.holcomb Line gerald.holcomb Rectangle gerald.holcomb Text Box E P gerald.holcomb Line

File details come from the government source that posted it. Updated .