SOW ATTACHMENT L PLUMBING PLANS.pdf

PDF 3 MB Posted

Attached to
Y1DB--Establish Radiation Oncology Program at SLVHCS Design Build - New Orleans
Solicitation number
36C77624R0107_1
Issued by

About this file

This document appears to be the plumbing plans (Attachment L) for a federal contract opportunity to Establish a Radiation Oncology Program at the Southeast Louisiana Veterans Health Care System in New Orleans, LA.

The key details include:

  • This is a design-build project for the Department of Veterans Affairs Technology Acquisition Center Austin.
  • The plumbing plans show the layout of various plumbing systems, including sanitary sewer, storm sewer, domestic water, and grease waste, for the new facility.
  • The plans provide information on pipe sizes, riser locations, floor drains, equipment connections, and other plumbing requirements.
  • The document includes general notes on installation requirements, such as supporting plumbing risers, providing isolation valves, and adjusting mixing valve temperature limits.
  • Several Request for Information (RFI) responses are referenced that made changes to the original plumbing design, such as relocating piping, deleting fixtures, and revising pipe sizes.

View the file

Other files

File Type Posted
SOW ATTACHMENT F DRAWING INDEX.pdf PDF
SOW ATTACHMENT I STRUCTURAL.pdf PDF
SOW ATTACHMENT D Google Map Facility and Construct Area.pdf PDF
RFP Attachment 18 - PPQ.docx DOCX document
SOW ATTACHMENT K - Pt 5 - MECHANICAL PLANS.pdf PDF
RFP Attachment 3 - 00 01 15 Drawing List.pdf PDF
RFP Attachment 9 - Rad Onc Site Supporting Drawings_Part6.pdf PDF
RFP Attachment 11 - FINAL Brand Name JA Rad Onc NOLA.pdf PDF
RFP Attachment 15 - Limitations on SubK SB.xlsx XLSX spreadsheet
SOW ATTACHMENT K - Pt 1 - MECHANICAL PLANS.pdf PDF
SOW ATTACHMENT J ARCHITECTUAL.pdf PDF
RFP Attachment 8 - Rad Onc Site Supporting Drawings_Part5.pdf PDF
RFP Attachment 2 - Specifications.pdf PDF
SOW ATTACHMENT C Block Graphic.pdf PDF
SOW ATTACHMENT K - Pt 4 - MECHANICAL PLANS.pdf PDF
SOW ATTACHMENT H FOUNDATION PLANS.pdf PDF
FINAL SOW NOLA Estab Rad Onc Program - 11-19-24.pdf PDF
SOW ATTACHMENT K - Pt 3 - MECHANICAL PLANS.pdf PDF
SOW ATTACHMENT G SITE UTILITIES.pdf PDF
SOW ATTACHMENT E Geotechnical Engineering Reports.pdf PDF
SOW ATTACHMENT M ELECTRICAL PLANS.pdf PDF
SOW ATTACHMENT K - Pt 2 - MECHANICAL PLANS.pdf PDF
RFP Attachment 1 - Radiation Therapy Design Guide.pdf PDF
SOW ATTACHMENT A Existing OIT Space.pdf PDF
SOW ATTACHMENT B Portion of OIT Space - Rad Onc.pdf PDF
RFP Attachment 4 - Rad Onc Site Supporting Drawings_Part1.pdf PDF
RFP Attachment 10 - RAD ONC PRELIM SKETCH.pdf PDF
RFP Attachment 14 - Services Rates - Orleans - 7-22-24.pdf PDF
RFP Attachment 13 - DBA Rates - Orleans - 7-19-24.pdf PDF
RFP Attachment 7 - Rad Onc Site Supporting Drawings_Part4.pdf PDF
RFP 36C77624R0107 11-21-24.pdf PDF
RFP Attachment 12 - Site Visit Information.pdf PDF
SOW ATTACHMENT N PROGRAM FOR DESIGN.pdf PDF
RFP Attachment 5 - Rad Onc Site Supporting Drawings_Part2.pdf PDF
RFP Attachment 6 - Rad Onc Site Supporting Drawings_Part3.pdf PDF
RFP Attachment 16 - Small Business SubK Plan LB.docx DOCX document
RFP Attachment 17 - Division Cost Breakdown.xlsx XLSX spreadsheet
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT L - PLUMBING PLANS

629-335 Establish Radiology Oncology Program at SLVHCS

(4)2"W UP

(4)2"W UP

3"W&T UP

2"V UP

2"W UP

4"GW UP TO FCO 6"GW UP

6" LOWER LEVEL

BUILDING SANITARY SEWER

SEE CIVIL ENGINEERING

DWGS. FOR CONTINUATION

INV. EL. 90'-9"

8"BUILDING SANITARY SEWER

(M.C.)SEE CIVIL ENGINEERING

DWGS.FOR CONTINUATION

INV. EL. 94'

15"BUILDING STORM SEWER

SEE CIVIL ENGINEERING

DWGS. FOR CONTINUATION

INV. EL. 95'

(28,500 SQ. FT.)

10"RL UP

(8,350 S.F.)

" R

L

6"GREASE WASTE BUILDING

SEWER SEE CIVIL ENGINEERING

DWGS. FOR CONTINUATION

INV. EL. 94'-3"

6"RL UP TO AD 6"RL UP TO AD

6"RL UP TO AD 6"RL UP TO AD

BACKWATER VALVE

WITH ACCESS PIT

10"RL UP TO FCO

4"GW UP TO FCO

ALL BELOW SLAB PIPING

(SANITARY, STORM, AND WATER)

SHALL BE HUNG FROM THE

UNDERSIDE OF THE SLAB. REFER

TO DETAIL DRAWING ON DWG 0P503

2"W UP

2"W UP

4"S UP

2"V UP

2"W UP

2"V RISE

2"V UP

2"V RISE

4"S UP

ACCESS PIT BY

OTHERS. REFER TO

STRUTURAL DWGS.

2P100-F

2P100-G

(3)1/2"TP UP

TO MANIFOLD

(2)2"V UP

4"W&T UP TO FD

4"W&T UP TO FD

4"W UP TO FCO

4"W UP TO FCO

2" V

2" V

1/ 2"

T P

1/ 2"

T P

4" SAN

6" SAN6" SAN

2"W UP TO FCO

2"W UP

4"W UP TO FCO

4"W UP TO FCO

4"W UP TO FCO

2"W UP4"W UP TO FCO

4"W UP TO FCO

4"W UP TO FCO

4"RL UP TO FCO

START INV. EL.=

4"W UP TO FCO

START INV. EL:=95'-5"

START INV. EL:=94'-5"

4"W UP TO FCO

4"W UP TO FCO

4"GW UP TO FCO

L.P.C.

5' - 0"

4"W UP TO FCO

4"RL UP T O FCO

FIRST FLOOR FINISH ELEVATION = 100'-0"

6" GW

8" S

A N

(M .C

6" SAN

6"RL UP TO FCO

GRADE BEAM PENNETRATION GRADE BEAM PENNETRATION GRADE BEAM PENNETRATION GRADE BEAM PENNETRATION GRADE BEAM PENNETRATION GRADE BEAM PENNETRATION

L.P.C.

5' - 0"

L.P.C.

5' - 0"

10"BUILDING STORM SEWER

SEE CIVIL ENGINEERING

DWGS. FOR CONTINUATION

INV. EL. 94'

8"W UP TO FCO

L.P.C.

5' - 0"

(2)4"VS FROM EXTIRIOR

GREASE TRAP SEE

CIVIL ENGENEERING

DWGS. FOR CONTINUATION

4"V UP(LIFT STATION)

(2)4"V UP(GREASE TRAP)

8"SS UP (658 DRAINAGE FIXTURE UNITS UP)

12"RL UP

(20,150 SQ.FT.)

4"LIFT STATION VENT

SEE CIVIL ENGENEERING

DWGS. FOR CONTINUATION

L.P.C.

5' - 0"

4" V 4" V

12" RL

8" SAN (M.C.)

8" S

A N

(M .C

4" V

4" V

(2)1/2"TP UP

TO MANIFOLD

1/ 2"

T P

1/ 2"

T P

6" S

A N

4"W&T UP

6"W & T UP

2"V UP

2"W UP

2"W UP

4"W& T UP

4"W&T UP(2)2"V UP

2"V UP

4"W UP TO FCO

4"W UP TO FCO

6" S

A N

6" S

A N

6" SAN

4" S

A N

4" S

A N4"

S A

N

4" SAN

2"V UP

6"W UP TO FCO

LPC

5' - 0"

6" SAN

6" R

L 6" R

L

6" R

L

6" R

L

6" RL

6" R

L

6" R

L

6" R

L

6" RL

1008 DRAINAGE FIXTURE UNITS

+65.1GPM CONTINUOUS

FLOW FOR EQUIPMENT

254 DRAINAGE FIXTURE UNITS

6" SAN

4"W UP

2"V UP

4"W & T UP

1/2" TP

1/2" TP

2"W UP

1/ 2"

T P

(2)1/2"TP UP

1/2"TP UP

2"W UP

2"W UP

4"W UP

4"W UP4" SAN

3"W&T UP

2"V UP

4"S UP

2"V UP

2"W&T UP

2"V UP

2" W&T UP

2"V UP

4"S UP

2"V UP

2"W UP

3"W&T UP

2"W UP

4"S UP TO FCO

4"S UP TO FCO

6" S

A N

02 E 02 D C

02 B

XA

02 H F.9

A.5

AA

AA.2

Y49

16.1

02 J

13.2

A

EJ 3

02 F

6" S

A N

(2)4"S UP

3"W&T UP

(3)4"S UP

(2)3"W UP

3"W&T UP

(3)4"S UP

4"W UP TO FCO

2"V UP

2"V UP

4"S UP

2”W UP

4"W UP TO FCO 2"V UP

4"S UP

2”W UP

4"W UP TO FCO

3"W&T UP

2"V UP

2"V UP

2"W&T UP

2"V UP

4"S UP

2"W UP

2"W UP TO FCO

4"W UP TO FCO

6" RL

4"W UP TO FCO

10" RL

4"W UP TO FCO

2" S

A N

6" GW

4" S

A N

2" SAN

4" S

A N

4" S

A N

6" SAN

4" SAN

6" SAN

SS

6"RL UP TO AD

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

08 P

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

2PL100-G

BLDG 2 UNDERSLAB PLUMBING PLAN - AREA G

RVD CADDFebruary 29, 2012

02629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING/ PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

RFI 01165:

VALVE PIT

REMOVED

RFI:01275 - 12" storm sewer continuation in lieu of 15".

92.5'

RFI:01308 - Pipe Elevation Change

REFER TO SKETCH:

SK-8-1-NJ-2-PL-100-G-1

REFER TO SKETCH:

SK-8-1-NJ-2-PL-100-G-1

RFI 01758:

COMBINE VENT

STACKS INTO ONE

(1) FROM

UNDERSLAB TO

ROOF

UP

P-414P-414

P-101A

P-528

P-528

2P101-F

2P101-G

COMP

ADP STOR

1G167

C4

UNASSIGNED

1G197

G8

FEMALE

1G100A

T1

STAFF

LOUNGE

1G118

S15

EC

1G195

G2

SERVICE

BAY

1G227

G8A

TELECOM

1G227C

G2

EMER

ELEC

1G227B

G2

NORM

ELEC

1G227A

G2

MALE

1G100B

T1

CONF/

TRAINING

1G138

S9A

PAGERS

CELLS

1G184

C4

LAPTOPS

1G191

S2

PROF

STAFF

1G182

S4

WORK

AREA

1G174

S17

PROGRAM

1G176

S4B

PROGRAM

1G183

S4

HELP

1G188A

S4

HELP

1G190

S4

HELP

1G188B

S4

PC TECH

1G185D

S4B

PC TECH

1G166A

S4B

PC TECH

1G165

S4B

PC TECH

1G185E

S4B

PC TECH

1G185B

S4B

PC TECH

1G185H

S4B

PC TECH

1G185I

S4B

PC TECH

1G185C

S4B

PC TECH

1G185G

S4B

PC TECH

1G166B

S4B

CONFERENCE

1G196

S9A

OFFICE

ASST CH

1G169

S3A

REF LIB

1G186

S9

OFFICE

SEC CH

1G171

S3A

OFFICE

SEC CH

1G172

S3A

PROF

STAFF

1G178G

S4B

PROF

STAFF

1G178A

S4B

PROF

STAFF

1G175

S4

OFFICE

CIO

1G168

S3A

OFFICE

BUDGET

1G170

S3A

COPY

ROOM

1G173

S18

SECY

1G177

S4B

PROF

STAFF

1G178F

S4B

ST

1G181

T4

PROF

STAFF

1G178E

S4B

PROF

STAFF

1G178D

S4B

PROF

STAFF

1G178H

S4B

PROF

STAFF

1G178C

S4B

PROF

STAFF

1G178B

S4B

WS,VAVS

ORGANIZATION

1G115

C11

OFFICER

1G110

S3A OFFICER

1G109

S3A

CHIEF OF

SERVICE

1G111

S7

CONFERENCE

1G113

S9A

VOLUNTEER

LOUNGE

1G108

S15

RECEPTION/SECY

1G116

C11

STORAGE

1G106

C55E

MULTI-PURPOSE

WORK

1G107

S3A

SIGN-IN

1G105

C11

ST

1G180

T4

HK

1G125

C3

CUSTOMER

SERVICE

1G189

S9B

SECY/

WAITING

1G162

S4B

ID ISSUE

WAIT

1G149

CORR70A

ID/REG

ISSUE

1G148

S2

PHYSICAL

SECUR

OFFICER

1G157

S3A

EVIDENCE

1G151

C55E

MALE

LOCKER

1G141A

S14

DETECTIVE

1G156

S3A

DETECTIVE

1G159

S3

TRAINING

OFFICER

1G158

S3A

ASST

CHIEF

1G154

S3A

CLER

1G161G

S4B

ID/KEY

STORAGE

1G147

C55E

ARMORY

1G145

C55E

ARMORY

STORAGE

1G146

C55E

ASST

CHIEF

1G153

S3A

LT/SGT

SUPER

1G155

S3A

COPIER

1G150

S18

HOLDING

1G160

C55E

SECURITY

COMMAND

CENTER

1G139

S2

FEMALE

LOCKER

1G140A

S14

CLER

1G161K

S4B

CLER

1G161H

S4B

CLER

1G161A

S4B

CLER

1G161D

S4B

CLER

1G161B

S4B

CLER

1G161C

S4B

CLER

1G161E

S4B

CLER

1G161I

S4B

CLER

1G161J

S4B

CLER

1G161F

S4B

HC T/S

1G141C

T5A

HC T/S

1G140B

T5A

T/S

1G141B

T5A

ST

1G121

T4

ST

1G122

T4

CORR

1G-C06

C11

CORR

1F-C06

CORR70A

CORR

1G-C02A

CORR70A

CORR

1G-C04

CORR75

CORR

1G-C03

CORR70A

CORR

1G-C02C

CORR1

WC

STORAGE

1G198

C17

CORR

1G-02B

CORR70A

CORR

1G-C08

S4B

CORR

1G-C09

S4B

PC TECH

1G185F

S4B

PC TECH

1G185A

S4B

SECURITY

1G227D

S19

OFFICE

1G135

S2

CLERICAL

1G132

S4

RECPT/WAIT

1G131

S4B

LOCKERS

1G129

S14

CHIEF

1G133

S7

AO

OFFICE

1G134

S2

COPY

1G130

S18

STRETCHER

STOR

1G128

C4

DISPATCH

1G123A

S15

BREAK

1G123B

S15

UNASSIGNED

1G120

C55E

T

1G102

T2A

T

1G101

T2A

CORR

1G-C15

S4

CORR

1G-C16

S4

CAFE

1G103

P13B

STORAGE

1G104

P13D

STOR

1G113B

C55E

STOR

1G113A

C55E

CLERICAL

1G114

S4

CORR

1G-C18

CORR75

STAIR

2F152

G1

UNASSIGNED

1G161L

NONE

3"DCWL UP

2"DHWL UP

1"DHWLR UP

6"SS UP

6"VS UP

3"V UP

4"VS UP

4"SS UP

4"SS UP

6"GW UP

3"V UP

4"VS UP

FCO

4"SS UP

4"VS UP

FCO

6"SS UP

6"VS UP

12"RL UP&DN

(20,150 S.F.)

8"SS DN

(658 DRAINAGE

FIXTURE UNITS)

(3)4"V UP&DN

8"RL DN

(8,350 S.F.)

6"RL UP TO RD

(2,350 S.F.)

6"RL UP TO RD

(2,500 S.F.)

6"RL UP TO RD

(3,500 S.F.)

4"S DN & 2"V RISE

1 1/2"DCWL

1/2"DHWL DROP

2"W DN & V RISE

1/2"DHWL DROP

8" RL

8" RL

1/ 2" D C W L

2" DHWL

4"S UP

2"W UP

2"W UP

2" SAN (M.C.)

2"W UP

2"W UP

2"W UP

2"W UP

2"W UP

2"W UP

4"S UP

2"W DN&V RISE

1 1/2"DCWL DROP

1/2"DHWL DROP

2"V DN&RISE

4"S DN

2"W UP 2"W UP

2"W UP

2"W UP

1/2"DCWL DROP

2"V DN&RISE

1/2"DHWL DROP

2"V DN & RISE

4"S DN

2"V DN&RISE

1 1/2"DCWL DROP

1/2"DHWL DROP

2"W DN&V RISE

FCO

2"V DN&RISE

1/2"DCWL DROP

1/2"DHWL DROP

4"S DN

2"V DN&RISE

1 1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

2"V DN&RISE

1/2"DCWL DROP

1/2"DHWL DROP

4"S DN

2"V DN&RISE

1 1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

4"S UP 4"S UP

3"W&T UP

2"V UP

2"W UP

6" S A N (M

.C

4"SS UP

4"VS UP

2"W UP2"W UP

2"W UP

2"W UP

2"W UP

4"S UP

2"W DN&V RISE

3/4"DHWL DROP

2"DCWL DROP

4"S DN

2"V DN&RISE

4"S DN

2"V DN&RISE

3"W DN

3/4"DHWL DROP

3/4"DCWL DROP

6"SS UP

4"S DN

(2)4"S

2"V RISE

(2)4"S

2"V RISE

(2)4"S 2"V RISE

4"S

3"S DN&2"V RISE

2"V RISE

3"S UP

2"V RISE

3"S UP

3"S DN&2"V RISE

2 1/2"DCWL DROP

6"VS UP

2"W DN&V RISE

2"W UP

2"W DN&V RISE

3/4"DHWL DROP

3/4"DCWL DROP

2"W UP

2"W DN&V RISE

2"W UP

2"W DN&V RISE

2"W UP

1/2"CW DROP

2"W DN&V RISE

2" D C W L

FCO

P-101A

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

6"RL UP TO AD 6"RL UP TO AD

6"RL UP TO AD

6"RL UP TO AD

6"RL UP TO AD

2"W UP

2"W UP

3"V UP

8" RL

8" RL

3" SAN (M.C.)

2" SAN (M.C.)

2" V

8" SAN (M.C.)

2" SAN (M.C.)

4"S DN & 2"V RISE

1 1/2"DCWL DROP

3/4"DCWL DROP

2"W DN&V RISE

3/4”DHWL DROP

6" RL6" RL

8" RL

1" D H W R L

1 1/2" DHWL

2" DHWL

3" D C W L

2" D C W L

3/ 4" D C W L

P-712

(5)P-101

(3)P-101 P-202

P-201

(4)P-417

(4)P-417

P-609

P-609

P-414P-414

P-101A P-101A

P-504

P-101A

P-414

P-414P-101A

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

P-804

P-804

FCO

FCO

AHU BY HVAC

4"W&T UP

2"V UP

6" S A N (M

.C

6" S A N (M

.C

4"W&T UP

2"V UP

TP MANIFOLD

3/4"DCWL DROP

(3)1/2"TP DN

TO FD'S

1/2"TP UP

TO MANIFOLD

(2)2"V DN & RISE

3" V

2"W DN & V RISE

1 1/4"DCWL DROP

TMV

1 1/2"TW RISE

1-1/4"DHWL DROP

ACCESS PIT BY

OTHERS. REFER TO

STRUTURAL DWGS.

4"W&T UP

8" SAN (M.C.)

2"V UP

P-804

FCO

FCO

2PL405

4"FD-B

4"FD-B

3/ 4" D C W L

2" V

3" V

3/4"DCWL DROP

FCO

1" D H W R L

FCO

FCO

FCO

2" D H W L

3" S A N (M

.C

3" SAN (M.C.) 3" SAN (M.C.)

3" S A N (M

.C

2"W UP

4"FD-B

4"FD-B

TP MANIFOLD

3/4"DCWL DROP

(2)1/2"TP DN

TO FD'S

ALL OVERFLOW STORM WATER DRAINS AND

OVERFLOW STORM WATER RELEIF PIPING SHALL

TERMINATE WITH A DOWNSPOUT COVER AT THE

FACADE OF THE BUILDING PRIOR TO THE START

OF WORK. THE PLUMBING SUB CONTRACTOR SHALL

COORDINATE THE EXACT LOCATION OF COVERS

WITH THE ARCHITECT AND CONSTRUCTION MANAGER

1/ 2" T P

(2)1/2"TP UP

TO MANIFOLD

3" D C W L

3" D C W L

3/4" DCWL

2 1/2" DCWL

2 1/2" DCWL2" DCWL2" DCWL

2" DHWL

1 1/4" DHWL

1 1/2" DCWL

2" D H W L

1/ 2" D H W L

1 1/2" DHWL

1" DHWL

DSP-1 CHEMICAL DISPENSING

SYSTEM SEE DETAIL ON DWG OP508

8" R L

FCO

FCO

4"W & T UP

1/2"TP UP

2"V UP

4"W & T UP

1/2"TP UP

2"V UP

4" SAN (M.C.)

2"V UP

1/2"TP UP

4"W & T UP

3" V

4"OED SEE DETAIL ON DWG OP509

4"W DN & 2"V RISE

4"FD-B

2"V DN & RISE

1-1/2"DCWL DROP

1-1/2"RPBP FOR

HVAC

OP509

8"RLR

1/2"TP UP TO

MANIFOLD

P-101A

P-413

P-413

P-101A

P-528

P-701

P-701

P-414 P-101A

P-701

6" SAN (M.C.)

4"S UP

6" GW

4" S A N (M

.C

6"GW DN

FCO

1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

2"W UP

1/ 2" D H W L

1/ 2" D H W L

1/ 2" D H W L

PROVIDE EXPANSION

JOINT ASSEMBLIES

(FLEXIBLE CONNECTIONS)

IN ALL PIPING MAINS

PROVIDE EXPANSION

JOINT ASSEMBLIES

(FLEXIBLE CONNECTIONS)

IN ALL PIPING MAINS

PROVIDE EXPANSION

JOINT ASSEMBLIES

(FLEXIBLE CONNECTIONS)

IN ALL PIPING MAINS

PROVIDE EXPANSION

JOINT ASSEMBLIES

(FLEXIBLE CONNECTIONS)

IN ALL PIPING MAINS

1 1/4" DCWL

1/ 2" D H W L 1/ 2" D H W L

3" V

6" SAN (M.C.)

4" S A N (M

.C

8" SAN (M.C.)

4" S A N (M

.C

3" S A N (M

.C

2" SAN (M.C.)

3" S A N (M

.C

3"FD-C

3"FD-C

3"FD-C

TP MANIFOLD

3/4"DCWL DROP

(2)1/2"TP DN

TO FD'S

TP MANIFOLD

3/4"DCWL DROP

(1)1/2"TP DN

TO FD

2"V DN & RISE

3"W UP

3"W DN & 2"V RISE

3/4”DCWL DROP

FCO

2"W DN&V RISE

2"W UP

2"W DN&V RISE

2"W UP

2"W UP

2"W DN&V RISE

3/4"DCWL DROP

3/4"DHWL DROP

2"W UP

2"W DN&V RISE

2" V2" V2" V

1/2" TP

FCO

02 E 02 D C

02 B

XA

02 H F.9

A.5

AA

AA.2

16.1

02 J

EJ

3.1

13.2

A

EJ 3

02 F

FCO

FCO

2" D H W L

1" D H W R L

1/ 2" D C W L

1/ 2" D H W L

1/ 4" D H W L

2 1/2" DCWL

1" D H W L( 0)

1" D H W L( 0)

1/ 2" D H W R L( 0)

1/ 2" D H W R L( 0)

1" D H W L( 0)

1" DHWL(140)

1/2" DHWRL(140)

SS

4G

VS

4G

SS

4D

SV

4D

SL

1D

SS

4F

VS

4F

SS

4E

VS

4EVS

4B

SS

4B

SS

4C

VS

4C

SS

SS

4A

VS

4A

FCO

FCO

4" S A N (M

.C

8" R

LR

8" RLR

3" V

FCOFCO

FCO

FCO

3" V

3" V 3" V

3" V

3" V

3" V

3" V

FCO

2"W UP

6" S A N (M

.C

4" S A N (M

.C

2"FD-C

2"FD-C

2"FD-C

1/2" TP

3" V

1/ 4" D H W L

FCO

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

08 P

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

2PL101-G

BLDG 2 FIRST FLOOR PLUMBING PLAN - AREA G

RVD CADDFebruary 29, 2012

02629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING/ PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

1. ALL HORIZONTAL PIPING SHALL BE INSTALLED IN THE INTERSTITIAL

SPACE UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OWN ALL

REQUIRED CORING, SLEEVING, FIRESTOPPING, ETC. REFER TO

ARCHITECTURAL PLANS FOR INTERSITIAL SLAB CONSTRUCTION.

2. ALL DOMESTIC (POTABLE)AND NON DOMESTIC (NONPOTABLE) HOT,

COLD, AND HOT WATER CIRCULATION PIPING SHALL BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR IN ORDER TO MAINTAIN HOT WATER

TEMPERATURE TO ALL FIXTURES. IF PIPING CAN'T BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR, PIPING SHALL BE INSTALLED

BETWEEN THE INTERSTITIAL SPACE FLOOR AND THE CEILING AND THE

PIPING SHALL BE LOOPED TO ALLOW CONTINUOS HOT WATER

CIRCULATION.

3. ALL STACKS AND RISERS SHALL BE SUPPORTED AT THE INTERSTITIAL

SPACE FLOOR OR JUST ABOVE THE CEILING WHERE THE INTERSTIAL

SPACE DOES NOT EXIST. SEE DETAILS ON DWG 0P506.

4. PROVIDE A BALL VALVE IN THE OPEN POSITION WITH A LOCK AND CHAIN

AT ALL EMERGENCY SHOWERS

5. DRAIN VALVES SHALL BE PROVIDED AT THE BASE OF ALL PLUMBING

RISERS

6. ALL ISOLATION VALVES AT RISERS SHALL BE INSTALLED IN AN

ACCESSIBLE LOCATION, NO MORE THAN 12" ABOVE FINISHED CEILING

7. ALL MIXING VALVE AT SHOWERS SHALL HAVE THE TEMPATURE LIMIT

STOP ADJUSTED TO THE REQUIRED VA STANDARDS

GENERAL NOTES

REFER TO SKETCH:

SK-8-1-NJ-2-PL-101-G-1

Prebid RFI EWP-08-0793:

Specification 22 05 11 2.15 applies to expansion joints

Correspondence No. 04924: Trap Primers have been deleted and Trap Guards installed.

Correspondence No. 04924: Trap Primers have been deleted and Trap Guards installed.

RFI 01809.1: DELETE (2) 4"

FD-B's, (1) P-804, (2) P-712, (1) RPBP for HVAC

RFI 029962: P-528 sink confirmed at this location.

RFI 06378: Sink type P-417 confirmed

RFI 06985.1:

Cap and grout

4" FD-B

DN

UP

UP

P-104A

P-414 P-414P-414

P-504

P-414

P-414

P-414

P-414

P-414

P-414

P-414

P-414

P-104A P-414

P-104A P-414

P-414

P-414

P-414

P-414

P-414

4"FD-B

2P102-F

2P102-G

P-414

P-414

UNASSIGNED

2G230

CORR

2G-C02

CORR

2G-C03

CORR

2G-C05A

CORR

2G-C07

CORR

2G-C06B

CORR

2G-C10

CORR

2G-C08A

CORR

2G-C09

CORR

2G-C11

CORR

2G-C04

CORR

2G-C06A

STAIR

STG-03

SHAFT

SHG13

CORR

2G-C05B

CORR

2G-C08B

CORR

2G-C06C

CC

2G119B

SCR

2G117

CLEAN

2G116

SOILED

HOLD

2G115MRI

2G129

MRI

2G128

CONTROL

2G131

SCR

2G127

GAS/CRY

ROOM

2G125

DRESS

2G194

DRESS

2G185

DRESS

2G191

DRESS

2G195

STRESS

2G193

STRESS

2G186

STRESS

2G196

STRESS

2G199

STRESS

2G190

ECHO

2G141

ECHO

2G140

STRESS

ECHO

2G139

PERIPHERAL

VASCULAR

2G182

VASC

TREAD

2G181

STRESS

ECHO

2G138

ECHO

2G136

EKG/

HOLTER

VIEW/WORK

2G192

DOSE

ADMIN NM

2G159

TILT

TABLE

2G180

CARD

EQUIP

2G183

T

2G143

T

2G202

NUCLEAR

MED

2G164

NUCLEAR

MED

2G151

DRESS

2G160

PET-CT

2G167

SCR

2G167B

HOT LAB

2G158

CONTROL

2G167A

NUCLEAR

MED

2G150

SUB-WAITING

2G201

RAD CONF

2G178

SERVICE

BAY

2G227

INTERVIEW

NM

2G189

DRESS

2G120

DRESS

2G114

DRESS

2G121

STAFF

WORK

2G119A

CARD

RECEPT

2G101C NUC MED

RECEPTION

2G101A

TELECOM

2G229A

EMER

ELEC

2G227B

NORM

ELEC

2G227A

PET READ

2G175

STORAGE

ECHO

2G137

SUB-WAIT

CARDIO

2G123

CONTROL

2G130

PAT HOLD

2G113

PAT HOLD

2G112

T

2G118

LINEN

2G124

EQUIP

STORAGE

2G122

HK

2G126

REF STOR

2G154

PHYSICIST

2G105

DRESS

2G198

RECEPTION

2G101B

STRET/WC

2G107

DRESS

2G155

DRESS

2G150A

DRESS

2G152

LINEN

2G163

AMBULETTE

2G145

AMBULETTE

2G144

DRESS

2G111

REF STOR

2G153

CC

2G184

EC

2G177

MALE

2G100B

LOUNGE

2G176

DRESS

2G200

MRI

WAITING

2G110

T

2G165

SERVICE

BAY

2G228

T

2G142

SECURITY

2G229B

STRESS

2G197

ECHO

READING

2G187

CARD

EQUIP

2G188

HK

2G106

SOILED

HOLD

2G166

COPY/WORK

2G103

STAIR

2F152

FEMALE

2G100A

SHAFT

SHG11

S H A F T

S H G

EC

2G183A

6"VS UP & DN

6"WS UP & DN

1 1/4"DHWRL UP & 1" DN

2 1/2"DHWL UP & 2" DN

4"DCWL UP & 3" DN

2"W UP

6"GW UP&DN

3"V DN&RISE

4"VS UP&DN

4"SS UP

4"SS DN&RISE

2"W UP

4"S UP

2"W UP

2"W UP

2"W UP

6" SS UP & DN

6"VS UP&DN

6"RL UP

(2375 S.F.)

6"RL UP

(2350 S.F.)

10"RL UP&12"RL DN

(20,150 SQ.FT.)

6"RD-B

(2,350 S.F.) 6"RD-B

(2,500 S.F.)

6"RD-B

(3,500 S.F.)

(2)2"W&V RISE

3/4"DHWL&DCWL DROP

2"W&V RISE

2"W UP

2"W DN&V RISE

2"W UP

1/2"DCWL DROP

3"W DN & 2"V RISE

6"SS UP&DN

2 1/2"DCWL DROP

(2)4"S

2"V RISE

(2)4"S

2"V RISE

(2)4"S

2"V RISE

4"S

3"S DN&2"V RISE

(2)2"V RISE

3"S DN&2"V RISE

6"VS UP&DN

(2)2"W&V RISE

3/4"DHWL&DCWL DROP

2"W&V RISE

2"W UP

2"W DN&V RISE

2"W UP

P-414

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

3" S

A N

(M .C

3" SAN (M.C.)

4" SAN (M.C.)

3" SAN (M.C.)

(3)2"W UP

3" SAN (M.C.)

4"SS UP&DN

4"VS UP&DN

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

1/2"DHWL DROP

2"V RISE

2"DCWL DROP

4"S DN&2"V RISE

2"W UP

4"S UP

2"W UP

1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

3/4"DCWL DROP

3"W DN& 2"V RISE

3/4"DHWL DROP

2"W UP

2"W UP

2"W UP

4"S DN&2"V RISE

1 1/2"DCWL DROP

1/2"DHWL DROP

2"W&V RISE

4"S DN&2"V RISE

1 1/2"DCWL DROP

1/2"DHWL DROP

1/2"DCWL DROP

2"W&V RISE

1/2"DHWL DROP

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

1/

4" D

H W

L

1/ 4"

D H

W L

1 1/2" DHWL

1 1/4" DHWL

2" DCWL2" DCWL

1/2"DCWL DROP

2"W DN & V RISE

1/2"DHWL DROP

1/2"DCWL DROP

2"W DN & V RISE

1/2"DHWL DROP

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

2" DCWL

2" D

C W

L

1/ 2"

D H

W L

1/

2" D

H W

L 1 1/2" DHWL

1 1/2" DCWL

1/2" DCWL

1/2"DCWL DROP

2"W DN & V RISE

1/2"DHWL DROP

2"W UP

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

1/2" DCWL

1/2"DCWL DROP

2"W DN & V RISE

1/2"DHWL DROP

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

2”W UP

1/

2" D

H W

L

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

4"S UP

2"V UP

2"W UP

2"W&V RISE

2"DCWL DROP

1/2"DHWL DROP

4"S DN&2"V RISE

4"S UP

1 1/2" DHWL1 1/2" DHWL

2" DCWL

4"SS UP&DN

4"VS UP&DN

3"V DN&RISE

4"VS UP

4"SS UP&DN

3" V

1/ 2"

D C

W L

1/2"DCWL DROP

2"W DN & V RISE

1/2"DHWL DROP

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

P-414

P-414

P-414

P-104A

P-414

P-414

4"S DN&2"V RISE

1/2"DHWL DROP

1 1/2"DCWL DROP

2"W V RISE

P-528

P-414

P-414 P-104A

P-504

(3)P-104 P-202 P-201

2"W UP

2" S

A N

(M .C

2"W UP

2"W UP 2"W UP

2" DHWL

2" DCWL2" DCWL

2" DCWL1 1/2" DCWL

3" V

2" V

3" V

3" V

1/

4" D

H W

R L

P-712

2"W DN & V RISE

1-1/4"DCWL DROP

TMV

1 1/2"TW RISE

1-1/4"DHWL DROP

1/ 2"

D C

W L

1/

4" D

H W

L

2" DCWL

1 1/2" DHWL 1 1/2" DHWL

1 1/4" DHWL1

1/

2" D

H W

L

1 1/2" DHWL

1 1/4" DHWL

1 1/2" DHWL

(4)P-417

P-804

4"FD-B

2"V DN & RISE

2"V UP

4"W&T UP

TP MANIFOLD

3/4"DCWL DROP

1/2"TP DN

TO FD'S

1/2"TP UP

TO MANIFOLD

3/4"DCWL DROP

TO HOSE BIBB

P-804

3/4" DCWL

2" V3" V

2" V

4" S

A N

(M .C

1/2" TP

AHU BY HVAC

4"W&T UP

AHU BY HVAC

1/2"TP UP

TO MANIFOLD

2"V DN & RISE

2" V

2" V

2" V

2" SAN (M.C.)

4" S

A N

(M .C

2" V

2" V

2" V

2" V

2" V 2" V

2" V

4" S

A N

(M .C

4" SAN (M.C.)4" SAN (M.C.)

4" S

A N

(M .C

2"V UP

(3)4"VS UP&DN

TP MANIFOLD

3/4"DCWL DROP

1/2"TP DN

TO FD'S

1 1/4"DCWL DROP

TMV

1 1/2"TW RISE

1 1/4"DHWL DROP

P-804

3/4"DCWL DN

P-609

P-609

TP MANIFOLD

3/4"DCWL DROP

(2)1/2"TP DN

TO FD'S

1/2" DCWL

1/2" TP

1/2" TP

(2)1/2"TP UP

TO MANIFOLD

1" D

C W

L

3/ 4"

D C

W L

1 1/2" DHWL

1 1/4" DHWL

1/ 2"

D C

W L

1 1/4" DHWL

P-804

CHEMICAL DISPENSING

SYSTEM SEE DETAIL

ON DWG. OP508

DSP-1

DSP-1

CHEMICAL DISPENSING

SYSTEM SEE DETAIL

ON DWG. 0P508

2" S

A N

(M .C

4” FD-B

4” FD

3" V

4” FD

2"V DN & RISE

2"DCWL DROP

2"RPBP

TP MANIFOLD

3/4"DCWL DROP

(1)1/2"TP DN

TO FD'S

TP MANIFOLD

3/4"DCWL DROP

(1)1/2"TP DN

TO FD'S

2"DCWL DROP

2"RPBP

2"V DN & RISE

1 1/2" DCWL

6" R

L

4"S UP 4"S UP

(2)2"W UP

TP MANIFOLD

3/4"DCWL DROP

3/4"RPBP

1/2"TP DN TO FD

(5)P-104

(4)P-417

4" SAN (M.C.)

2"W UP

2"W UP

2"W UP

2" S

A N

(M .C

2" SAN (M.C.)

4" S

A N

(M .C

4" SAN (M.C.)

1 1/4" DHWL

1/2" DCWL

2" DCWL

1 1/4" DHWL

2"W UP

4"S UP

2"W UP

3"V DN&RISE

2"W UP

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

4" SAN (M.C.)

2" S

A N

(M .C

.) 3/4"DCWL DROP

3/4"DHWL DROP

3"W DN

2"V DN&RISE

1/2"DHWL DROP

2"WDN&VRISE

1/2"DCWL DROP

1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

1/2"DHWL DROP

2"W DN&V RISE

1/2"DCWL DROP

2"V DN

3"W&T UP

2"V UP

3" S

A N

(M .C

4" SAN (M.C.)

2" SAN (M.C.)

4" S

A N

(M .C

3" SAN (M.C.)

4" S

A N

(M .C

2"W UP 2"W UP

2"W UP

1/

2" D

C W

L

1/ 2"

D C

W L

2" SAN (M.C.)

2"W UP

2" V

P-712

2" V

2"W UP

2"W DN & V RISE

1/

2" D

H W

L

1/

4" D

H W

L

3" V

4" SAN (M.C.)

3" V

3" V

3" V

1/ 2"

T P

1/2" TP

(4)1/2"TP UP

1/ 2"

T P

1/ 2"

T P

02 E 02 D C

02 B

XA

02 H F.9

A.5

AA

AA.2

Y49

16.1

EJ

3.1

A

EJ 3

02 F

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

4"S UP

SL

1D

3" V

2" V 2" V

SS

4A

VS

4A

VS

4B

SS

4B

SS

4C

VS

4C

SS

4D

VS

4D

SS

4E

VS

4E

SS

4F

VS

4F

SS

4G

VS

4G

3" V

2" V

1/

2" D

C W

L

1/

4" D

H W

R L

4"FD-A

4"FD-A

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

08 P

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

2PL102-G

BLDG 2 SECOND FLOOR PLUMBING PLAN - AREA G

RVD CADDFebruary 29, 2012

02629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING/ PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

1. ALL HORIZONTAL PIPING SHALL BE INSTALLED IN THE INTERSTITIAL

SPACE UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OWN ALL

REQUIRED CORING, SLEEVING, FIRESTOPPING, ETC. REFER TO

ARCHITECTURAL PLANS FOR INTERSITIAL SLAB CONSTRUCTION.

2. ALL DOMESTIC (POTABLE)AND NON DOMESTIC (NONPOTABLE) HOT,

COLD, AND HOT WATER CIRCULATION PIPING SHALL BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR IN ORDER TO MAINTAIN HOT WATER

TEMPERATURE TO ALL FIXTURES. IF PIPING CAN'T BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR, PIPING SHALL BE INSTALLED

BETWEEN THE INTERSTITIAL SPACE FLOOR AND THE CEILING AND THE

PIPING SHALL BE LOOPED TO ALLOW CONTINUOS HOT WATER

CIRCULATION.

3. ALL STACKS AND RISERS SHALL BE SUPPORTED AT THE INTERSTITIAL

SPACE FLOOR OR JUST ABOVE THE CEILING WHERE THE INTERSTIAL

SPACE DOES NOT EXIST. SEE DETAILS ON DWG 0P506.

4. PROVIDE A BALL VALVE IN THE OPEN POSITION WITH A LOCK AND CHAIN

AT ALL EMERGENCY SHOWERS

5. DRAIN VALVES SHALL BE PROVIDED AT THE BASE OF ALL PLUMBING

RISERS

6. ALL ISOLATION VALVES AT RISERS SHALL BE INSTALLED IN AN

ACCESSIBLE LOCATION, NO MORE THAN 12" ABOVE FINISHED CEILING

7. ALL MIXING VALVE AT SHOWERS SHALL HAVE THE TEMPATURE LIMIT

STOP ADJUSTED TO THE REQUIRED VA STANDARDS

GENERAL NOTES

Correspondence No. 04924: Trap Primers have been deleted and Trap Guards installed.

Correspondence No. 04924: Trap Primers have been deleted and Trap Guards installed.

Correspondence No. 04924:

Trap Primers have been deleted and Trap Guards installed.

RFI 01809.1: DELETE (1) P-804, (1)

P-712 ((1) 4" FD-B to remain for humidifier and add (1) 4" OED)

RFI 01809.1:

DELETE (1) P-804,

(1) P-712 ((1) 4" FD-B to remain for humidifier and add

(1) 4" OED)

RFI 05643: Sinks remain. Refer to RFI for requirements

RFI 05643.1: Re-confirmed that sinks are to remain.

RFI 05644: Compressor for MRI doors goes here. Drains into 2G126 mop sink

RFI 05782: Compressor shelf requirements provided

RFI 05782.1: Additional compressor shelf requirements provided. Condensate will drain into SCR floor drain

RFI 07396: MRI sinks removed & relocated to corridor. See attached sketch.

RFI 08098.1: Route Condensate lines to mop sink in Room 2G126 instead of floor drain

RFI 08367.1: Tie Backup bypass panel to 2" domestic water and provide required filter

RFI 08367.1: Tie Backup bypass panel to 2" domestic water and provide required filter

DN

UP

UP

P-104A

P-414

P-104A

P-414

P-104A

P-414

N-2

P-414

P-414 P-414 P-414

P-414

P-104 P-202

(2)P-104

P-414

P-414

P-414

P-505

P-414

P-504

(2)P-413

P-528

P-528

P-414

P-414

P -4

P -1 A

P -1 A

(2)P-413

P-414 P-414 P-414

P-414 P-414

P-414

P-414

P-414

P-417

2P103-F

2P103-G

P-609

STAIR

STG-03

CORR

3G-C02A

C O R R

3G -C C

CORR

3G-C02B

CORR

3G-C01

CORR

3G-C03B

C O R R

3G -C A

C O R R

3G -C B

CORR

3G-C08A

CORR

3G-C08B

CORR

3G-C03A

CORR

3G-C04

CORR

3G-C06

SHAFT

SHG13

STAFF

LOCKERS

3G193

GI ASSIST

3G145O

PHYS

3G146C

RN TECH

3G145K

ADMIN

3G146A

PHYS

3G145C

PHYS

3G145F

PHYS

3G145E

PHYS

3G145D

PHYS

3G145A

SECY

3G146B

RN TECH

3G145N

RN TECH

3G145L

RN TECH

3G145M

STAFF

LOCKERS

3G192

GI ASSIST

3G145J

GI ASSIST

3G145I

MALE

3G100B

EQUIP

STOR

3G108

STAFF

LOUNGE

3G194

PULM

RECEPT

3G101

EC

3G186

SERVICE

BAY

3G228

NURSES

STATION

3G124

STRETCHER

STORAGE

3G152

DIG

DISEASE

RESIDENTS

3G185

DICT/

VIEW

3G178

DG CLER

3G145P

PHYS

3G145B

T 3G127

PHYS

3G145G

CC

3G128

SERVICE

BAY

3G227

TELECOM

3G227A

EMER

ELEC

3G227D

NORM

ELEC

3G227C

FEMALE

3G100A

T 3G126

ISOL

3G103

ISOL

3G104

PULM

SCREEN

3G106

PFT

3G105

EXERCISE

PHYS

3G102

CYLINDER

3G108C

CC

3G107

PHYS

LOUNGE

3G191

STORAGE/

COPY

3G144

RES

CONF/

CLASSROOM

3G181

OFFICE

CHIEF

CARDIO

3G138

CHIEF

RESIDENT

3G137

OFFICE

NURSE

MGR

3G139

CONFERENCE

ROOM

(CL)

3G180

TEST

3G129

SOILED

3G134

RECOVERY

3G116

RECOVERY

3G122

RECOVERY

3G121

RECOVERY

3G118

CLEAN

3G125

RECOVERY

3G120

RECOVERY

3G117

GENERAL

ENDO

3G169

GENERAL

ENDO

3G168

ERCP

3G166

CLEAN

SCOPE

STORAGE

3G160

SCOPE

STORE

3G158

STRETCHER

STORAGE

3G171

T 3G165

T 3G175

CLEAN

3G162

SOILED

3G161

COPY/

WORK

3G179

PROCEDURE

BRONCH

3G153

GENERAL

ENDO

3G156

GENERAL

ENDO

3G155

CONTROL

3G153A

DG

PRIVATE

INTERVIEW

3G141

DG CHIEF

OFFICE

3G140

DG NURSE

MANAGER

3G143

DG SECY/

FILES

3G142

RECOVERY

3G119

LINEN

STOR

3G157

EQUIP

CLEAN-UP

3G159

STRETCHER

STORAGE

3G170

STRETCHER

STORAGE

3G154

HK

3G190

BLOOD

GAS

3G135

CLEAN

3G133

FULL

CYLINDER

3G151

RECOVERY

3G123

PHYS

3G145H

HC ST/S

3G192C

ST

3G176

ST

3G177

EMPTY

CYLINDER

3G150

CORR

3G-C11

CORR

3G-C12

CORR

3G-C09

CORR

3G-C10

CORR

3G-C13

TRAINING/

WORK

3G187

SECURITY

3G227B

MED PREP

3G163

PHYS

WORK

3G164

EUS/COMPLEX

3G167

SHAFT

SHG14

SHAFT

SHG11

HC ST/S

3G193C

RT

3G110C

RT

3G110D

RT

3G110E

RT

3G110B

RT

3G110A

CORR

3G-C12

RECOVERY

3G115

CORR

3G-C11

SECY/WAIT

3G136

6"RL UP & 10" RL DN

(15,425 SQ.FT.)

6"GW DN

4"SS UP&DN

4"VS UP&DN

8"RL UP

(5,450 SQ.FT.)

6"VS UP & DN

6"WS UP & DN

1 1/4"DHWRL UP & DN

2 1/2"DHWL UP & DN

4"DCWL UP & DN

4"W&T UP

2"W UP

2"W&T UP

2"V UP

4"SS DN&VS RISE

4"VS UP&DN

4"SS UP&DN

4"VS UP&DN

6" SS DN

6"VS UP&DN

4"S UP

3"W&T UP

3"W&T UP

GREASE AND SOLIDS INTERCEPTOR

SITTING ON STAND AT INTERSTITIAL

SPACE. SEE DETAIL ON 0PL509

6"RL UP

8"OFD UP

(2350 S.F.)

6"RL DN

(2375 S.F.)

6"RL DN

(2350 S.F.)

1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1 1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DHW DROP

2"W DN & V RISE

1/2"DCW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DHW DROP

2"W DN & V RISE

1/2"DCW DROP

1 1/4"DCW DROP

4"S DN & 2"V RISE

3/4"DHW DROP

1/2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

1/2"DHW DROP

2"W DN & V RISE

1/2"DCW DROP1 1/2"DCWL DROP

4"S DN & 2"V RISE

3/4"DHWL DROP

1/2"DHW DROP

2"W DN&V RISE

1 1/2"DCW DROP

4"W DN&2"V RISE

3/4"DHWL DROP

4"S DN&2"V RISE

3/4"DCWL DROP

2"W DN & V RISE

1 1/2"DCW DROP

3/4"DHW DROP

1/2"DCWL DROP

2"W DN&V RISE

1/2"DHWL DROP

1/2"DCWL DROP

2"W DN & V RISE

1 1/2"DHWL DROP

2" D H W L2" D H W L

4"S DN

2" DHWL

2" DHWL

2" DHWL

2" DHWL

2" D H W L

1/ 2" D H W L

1/2"DW DROP

1/2"DCW DROP

2"W DN & V RISE

1/ 4" D H W L

2" D C W L

1 1/4" DHWL 1 1/4" DHWL

3" D C W L

1" D H W R L

1 1/4" DHWL

1" DHWRL

1" DHWRL

1/2"DCW DROP

2"W DN & V RISE

2"W UP

2"W DN & V RISE

1/2"DCW DROP

1/2"DHW DROP

(3)2"W UP

6"SS UP

6"SS DN & RISE

(2)4"S

2"V RISE

2"DCW DROP

2"V RISE

4"S & 2" V RISE

3"S DN & 2"V RISE

6"VS UP & DN

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

2"W UP

2"W DN & V RISE

(2)2"W UP

1/2"DCWL DROP

1/2"DHWL DROP

2"W UP

P-414

2"V UP

6"GW&T UP

P-414

8"RWL UP

(5,575 SQ FT)

4"S DN & 2"V RISE

2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

4"S DN & 2" V RISE

2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

2"V UP

4"W & T UP

2"DCW DROP

2"W DN & V RISE

1/2"DHW DROP

4"S DN & 2" V RISE

1" DHWL1" DHWL1 1/4" DHWL1 1/4" DHWL

1/2" DCWL

P-104A

P-414

P-414

P-414

P-505

P-414

P-505

2"W DN & V RISE

3/4"DHWL DROP

3/4"DCWL DROP

2"W & V

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

2" V

2"W DN & V RISE

3/4"DHWL DROP

3/4"DCWL DROP

2"W & V

1/2"DHWL DROP

2"W DN & V RISE

1/2"DCWL DROP

6" GW

6" G W

6" GW

4" GW

6" GW

4" GW

4" GW

4" G W

P-712

2"W UP

2"W DN & V RISE

1-1/4"DCW DROP

TMV

1 1/2"TW RISE

1-1/4"DHW DROP

1 1/4" DHWL

P-414

P-414

P-414

3" V 2" V

2" V

2" V

2" V

2" V

2" V2" V 2" V

2" V

2" V

3" V

2" V

2" V

3/4" DCWL

2" V

3" V

2" V2" V

6" R L 6" R L

6" RL

4"FD-B

2"V DN & RISE

2"V UP

4"W&T UP

AHU BY HVAC

(2)1/2"TP UP

TO MANIFOLD

TP MANIFOLD

3/4"DCW DROP

1/2"TP DN

TO FD'S

3/4"DCW DROP

TO HOSE BIBB

P-804

4" SAN (M.C.)

2" V

TP MANIFOLD

3/4"DCWL DROP

1/2"TP DN

TO FD'S

AHU BY HVAC

1 1/4"DCWL DROP

TMV

1 1/2"TW RISE

1-1/4"DHWL DROP

P-804

3/4"DCWL DROP

2"V UP

1/2" TP UP

TO MANIFOLD

2" V

1/ 2" T P

2"V DN & RISE

4"FD-B

1/2"DCW DROP

2"W DN&V RISE

1/2"DHW DROP

4" RL

4" R L

4" RL

2" DHWL

2" D H W L

3" D C W L

1" D H W R L

1/ 4" D H W L

1" D C W L

1 1/2" DCWL

1 1/4" DHWL

3/4" DCWL

1/2" TP

(3)VS UP& DN

2" V

1" D H W R L

P-609

2" DHWL

(2)P-417

2 1/2" DCWL

3" DCWL

2"

2" DCWL

1" D H W L

TP MANIFOLD

3/4"DCWL DROP

(2)1/2"TP DN

TO FD'S

(2)1/2"TP UP

TO MANIFOLD

1/2" TP

1/ 2" T P

1/ 2" T P

1/ 2" T P

1 1/4" DHWL

1 1/2" DCWL

(2)1/2"TP UP

TO MANIFOLD

4"W UP

P-804 P-804

TP MANIFOLD

3/4"DCWL DROP

(4)1/2"TP DN

TO FD'S

4"RL UP

8" RL

8" RL

" O

FD

" O

FD

10" OFD

8" O

FD

8" OFD

8" O

FD

15"OFD

SPILL TO FACADE

(4,725 SQ.FT.)

2" DCWL

4"W & T UP

2"V UP

1/2" TP 1/2" TP

(2)P-417

P-528

1/2"DHW DROP

2"W DN & V RISE

2"DCW DROP

4" SAN (M.C.)

4" SAN (M.C.)

4" S A N (M

.C

2 1/2" DCWL

4" S A N (M

.C

4" S A N (M

.C

2" V

2" V

2"V DN&RISE

3"W DN

3/4"DCWL DROP

3/4"DHWL DROP

3/ 4" D C W L

2" D H W L

2" D H W L

3"W&T UP

2"V UP

3" SAN (M.C.)

4" S A N (M

.C

2" V

2" V

2 1/2" DCWL2 1/2" DCWL

2" V

4"VS UP&DN

4"SS UP&DN

2" V

2" V

2" V

2" SAN (M.C.)

P-712 1/2"DHWL DROP

2"W DN & V RISE

1/2"DHWL DROP

2"W DN & V RISE

2"W UP

6" GW

6" G W

3" V

3" V

4"W UP & T

2"V UP

8" RL

2" DCWL

02 E 02 D C

02 B

XA

02 H F.9

A.5

AA

AA.2

16.1

EJ

3.1

A

02 F

2 1/2" DCWL2" DCWL 2" DCWL2" DCWL3/4" DCWL

1/ 2" D C W L

2" D H W L

1/ 2" D C W L 2" D H W L

1/ 2" D C W L

2" D C W L

10" OFD

SL

1D

SS

4G

VS

4G

SS

4A

VS

4A

SV

4B

SS

4B

SS

4C

VS

4C

SS

4D

VS

4D

SS

4E

VS

4E

SS

4F

VS

4F

8" R L

3" V

2" D C W L

3" V3" V

3" V

3" V 2" V 2" V

3" S A N (M

.C

1 1/2" DHWL

6" GW

2"V UP

6"GW&T UP

4" SAN (M.C.)

4"GW&T UP

2"V UP

4"W&T UP

2"V UP

4"W&T UP

2"V UP

2"W UP

2"V UP

4"GW&T UP

2"V UP

2"W UP

4"GW&T UP

2"V UP2" V

2"W UP

4"W&T UP

2"V UP

4"W&T UP

(2)2"V UP

4"W&T UP

4"W&T UP

2"V UP

4"GW&T UP

2"V UP

(2)2"V UP

2"W UP

4"GW&T UP

(2)2"V UP

4"GW&T UP

(4)4"GW&T UP

(3)2"V UP 2"V UP

(3)2"GW UP

4"GW&T UP

2"V UP

4"GW&T UP

2"V UP

2"W UP

4"W&T UP

2"V UP

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

08 P

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

2PL103-G

BLDG 2 THIRD FLOOR PLUMBING PLAN - AREA G

RVD CADDFebruary 29, 2012

02629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING/ PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

1. ALL HORIZONTAL PIPING SHALL BE INSTALLED IN THE INTERSTITIAL

SPACE UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OWN ALL

REQUIRED CORING, SLEEVING, FIRESTOPPING, ETC. REFER TO

ARCHITECTURAL PLANS FOR INTERSITIAL SLAB CONSTRUCTION.

2. ALL DOMESTIC (POTABLE)AND NON DOMESTIC (NONPOTABLE) HOT,

COLD, AND HOT WATER CIRCULATION PIPING SHALL BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR IN ORDER TO MAINTAIN HOT WATER

TEMPERATURE TO ALL FIXTURES. IF PIPING CAN'T BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR, PIPING SHALL BE INSTALLED

BETWEEN THE INTERSTITIAL SPACE FLOOR AND THE CEILING AND THE

PIPING SHALL BE LOOPED TO ALLOW CONTINUOS HOT WATER

CIRCULATION.

3. ALL STACKS AND RISERS SHALL BE SUPPORTED AT THE INTERSTITIAL

SPACE FLOOR OR JUST ABOVE THE CEILING WHERE THE INTERSTIAL

SPACE DOES NOT EXIST. SEE DETAILS ON DWG 0P506.

4. PROVIDE A BALL VALVE IN THE OPEN POSITION WITH A LOCK AND CHAIN

AT ALL EMERGENCY SHOWERS

5. DRAIN VALVES SHALL BE PROVIDED AT THE BASE OF ALL PLUMBING

RISERS

6. ALL ISOLATION VALVES AT RISERS SHALL BE INSTALLED IN AN

ACCESSIBLE LOCATION, NO MORE THAN 12" ABOVE FINISHED CEILING

7. ALL MIXING VALVE AT SHOWERS SHALL HAVE THE TEMPATURE LIMIT

STOP ADJUSTED TO THE REQUIRED VA STANDARDS

GENERAL NOTES

REFER TO SKETCH:

SK-8-1-NJ-2-PL-103-G-1

RFI 01505: Rotate the mop basin 90 degrees to avoid conflict with the 2T2 steel truss

Correspondence No. 04924: Trap Primers have been deleted and Trap Guards installed.

Correspondence No. 04924: Trap Primers have been deleted and Trap Guards installed.

RFI 01809.1:

DELETE (1) P-804,

(1) P-712 ((1) 4" FD-B to remain for humidifier and add

(1) 4" OED)

RFI 01809.1: DELTETE (1)

P-804, (1) P-712 ((1) 4"FD-B

to remain and add (1) 4"

OED)

SEE RFI 02746 - EXPAND COLUMN

WRAP 3" EAST TO

ACCOMMODATE 6" GW RISER

RFI 03219: Interstitial capable of supporting interceptor assembly

THIS DRAWING HAS BEEN AFFECTED BY THE BIM

COORDINATION PROCESS. PLEASE REFER TO THE

BIM COORDINATED SHOP DRAWINGS FOR DETAILS.

LEVEL 3 GRAVITY LEVEL 3 PRESSURE

LEVEL 3i GRAVITY LEVEL 3i PRESSURE

SEE RFI 05314: Shifts wall and sink 20" North to accommodate foot pedals and bedpan washer

UP

P-202P-201

P-104A

P-104A P-202

(2)P-413

(4)P-417

4"FD-B

2P104-F

2P104-G

TELECOM

4G227A

STAIR

STG-03

SHG13

CORR

4G-C01A

CORR

4G-C04

CORR

4F-C09B

CORR

4G-C05B CORR

4G-C06

TELE PBX

4G108

SERVICE

BAY

4G227

EMER

ELEC

4G227D

NORM

ELEC

4G227C

NETWK

4G106J

PBX

4G106P

PBX

4G106N

TELE UPS

4G108A

PBX

4G106L

NETWK

4G106A

COMPUTER

ROOM MIS

4G110C

COMP

ACTIVE

STOR

4G110E

PBX

4G106M

PBX

4G106O

NETWK

4G106D

NETWK

4G106C

IMAGE

4G106T

IMAGE

4G106Q

IMAGE

4G106R

NETWK

4G106E

IMAGE

4G106S

NETWK

4G106K

TRAIN/

CONF RM

4G140

SUPV

TECH

4G121A

SUPV

TECH

4G121B

SUPV

TECH

4G121C

PRIVATE

MEETING

RM

4G142

CHIEF

NUTRITION

4G148

RECEPT

4G151

ASST

CHIEF

NUTRITION

4G146

CLINICAL

ADM SEC

CHIEF

4G144

SUPV

TECH

4G121D

CLERK

4G149B

CLERK

4G149A

DIET TECH

COMM

CENTER

4G147

PATIENT

PROD

MGR

4G150

DIET TECH

COMM

CENTER

4G145

RECEIVING

4G136

MAIN

KITCHEN

PATIENT

TRAY

SERIVCE

4G126

MAIN

KITCHEN

SANITATION

4G122

MAIN

KITCHEN

FOOD

PREP

4G124

DRY

GOODS

STOR

4G130

DHCP

COMPUTER

4G110B

EC

4G138

KITCHEN

ELEC RM

4G120

VISTA

4G106G

VISTA

4G106I

VISTA

4G106H

SECTION

CHIEF

4G101

STAFF

LOUNGE

4G134

HK

4G104

FEMALE

4G139

MALE

4G137

SERVICE

BAY

4G228

FEMALE

4A100A

MALE

4A100B

UPS ELEC

RM

4G110D

CORR

4G-C05A

CORR

4G-C07

CORR

4G-C05

SECURITY

4G227B

TEAM

SPACE

4G106U

STAIR

2F152

BACK-UP

SECURITY

COMMAND

CENTER

4G105

STOR

4G119A

HK

4G119B

SECTION

CHIEF

4G103

CABLE

VAULT

4G108B

CORR

4G-C01B

SHG11

S H G

MAIN

COMPUTER

ROOM

4G110A

CORR

4G-C01B

6"SS UP&DN

6"VS UP&DN

4"VS DN&RISE

4"SS DN&VS RISE

4"VS DN & RISE

4"SS DN & RISE

4"VSUP

4"SS DN&VS RISE

4"VS DN&RISE

4"VS DN&RISE

4"SS DN&VS RISE

10"OFD SPILL TO FACADE

10"OFD SPILL TO FACADE

6"RL UP

8"OFD UP

(2,650 SQ.FT.)

6"RL UP

8"OFD UP

(2,800 SQ.FT.)

6"RL UP

6"OFD UP

(2,700 SQ.FT.)

6"RL UP

8"OFD UP

(2,875 SQ.FT.)

6"RL UP

(4,400 SQ.FT.)

12"OFD

SPILL TO FACADE

(11,025 SQ.FT.)

6"RL DN

(4,400 SQ.FT.)

8"RL DN

(5,450 SQ.FT.)

8"RL DN

(5,575 SQ.FT.)

4"OFD UP

4"RL UP

(300 SQ.FT.)

6"VS DN

6"SS DN

4"DCWL DN

2 1/2"DHWL DN

1 1/4"DHWRL DN

QC-1

2"V DN&RISE

2"V DN&RISE

3"W DN

3"V DN&RISE

3"V DN&RISE

2"V DN

2"V DN&RISE

2"V DN&RISE

(4)3"GW DN

2"W DN&V RISE

2"V DN&RISE

2"W DN&V RISE

3"FD-C

3"FD-C 4"S DN

2PL404

2"DCWH DN

3/4"DHWH DN

3"V DN

10"OFD UP

(7,000 SQ.FT.)

1/

2" D

C W

H

1 1/4" DHWRH

1/2"DHWH DROP

2"W DN & V RISE

1/2"DCWH DROP

(2)2"W DN & V RISE

3/4"DHWH DROP

3/4"DCWH DROP

2"W DN & V RISE

6"SS DN

(2)4"S

2"V RISE

(2)4"S

2"V RISE

2 1/2"DCWH DROP

2"V DN & RISE

4"S

2"V RISE

3"S DN & 2"V RISE

4"S

2"V RISE

3"S DN & 2"V RISE

6"VS DN & RISE

3/4"DHWH DROP

2"V DN & RISE

3"W DN

3/4"DCWH DROP

1 1/4" DHWH

3/ 4"

D C

W H

3/4" DCWH

2" V

1 1/4" DHWRH(140)

2 1/2" DHWH(140)

2" DHWH

1 1/2" DCWH

1/

4" D

C W

H

1 1/4" DHWRH(140)

2 1/2" DHWH

3" V3" V

3" V

3" V

3" V

3" V

3" V

3" V

2" V

3" V

3" V

3" V

2" DHWH

2" D

H W

H

12" OFD

6" RL

" O

FD

8" OFD

6" RL

8" OFD

6" RL8" OFD

2" V

2" V

2" V

1/

4" D

C W

H

1 1/2" DHWH

" O

FD

" O

FD

2" V

2" V

2" V

2" V

2" V

(5)P-104

(3)P-104

(4)P-417

P-504

P-504

3" V

1/

4" D

H W

H

TP MANIFOLD

3/4"DCWH DROP

(2)1/2"TP DN

TO FD'S

6"VS UP

6" V

6" V

4" V

2" V

P-712

1-1/4"DCWH DROP

TMV

1 1/2"TW RISE

1-1/4"DHWH DROP

2"W DN & V RISE

3/4"DCWH DROP

TO HOSE BIBB

P-804

1 1/2" DCWH

1 1/4" DHWH

3/4" DCWH

TP MANIFOLD

3/4"DCWH DROP

1/2"TP DN

TO FD'S

1-1/4"DHWH DROP

TMV

1 1/2"TW RISE

2"W DN & V RISE

1 1/4"DCWH DROP

3/4"DCWH DROP

TO HOSE BIBB

4"W&V UP

2"V UP

AHU BY HVAC

2"V DN & RISE

2" V

1 1/2"DCWH UP

1 1/2"DHWH UP

P-804

1/2"TP UP

TO MANIFOLD

2" V

4"VS UP

2"V UP

4"W&T UP

2"V UP

4"W&T UP

1 1/2"DCWH UP

1 1/2"DHWH UP

4"W&T UP

4"FD-B

4"W&T UP

2"V DN & RISE

4"W&T UP

2"V UP

4"V UP

AHU BY HVAC

4" R

L

4"RL UP

4"RL UP

P-804

P-804

4"RL UP TO PLENUM DRAIN

1/

4" D

H W

R H

(1

4"

D C

W L

1/

4" D

H W

R L

3" D

C W

H

1/ 4"

D H

W R

H

1/ 2"

D H

W H

(1

4" D

C W

L

1/

2" D

H W

R L

1/

2" D

H W

L

ALL OVERFLOW STORM WATER

DRAINS AND OVERFLOW STORM

WATER RELIEF PIPING SHALL

TERMINATE WITH DOWNSPOUT

COVER AT THE FACADE OF THE

BUILDING. PRIOR TO THE START

OF WORK THE PLUMBING

SUBCONTRACTOR SHALL

COORDINATE EXACT LOCATIONS

OF COVERS WITH THE

ARCHITECT AND THE

CONSTRUCTION MANAGER.

ALL OVERFLOW STORM WATER DRAINS

AND OVERFLOW STORM WATER RELIEF

PIPING SHALL TERMINATE WITH DOWNSPOUT

COVER AT THE FACADE OF THE BUILDING.

PRIOR TO THE START OF WORK THE PLUMBING

SUBCONTRACTOR SHALL COORDINATE EXACT

LOCATIONS OF COVERS WITH THE ARCHITECT

AND THE CONSTRUCTION MANAGER.

(3)4"VS DN&RISE

(3)4"VS UP

4"W&T UP

2"V UP

2" D

H W

H

1/

2" D

C W

H

4" S

A N

(M .C

2" V

4" NG

1/

2" N

G

1/2" TP

1/ 2"

T P

2" V

2" V

1/ 2"

T P

4" V 2" V

P-712

2 1/2" DCWH

2" DHWH

2" D

H W

H

1 1/4" DHWH

1 1/4" DHWH

2 1/2" DCWH

1/2"DHWH DROP

2"W DN & V RISE

1/2"DCWH DROP

(2)2"W DN & V RISE

3/4"DHWH DROP

3/4"DCWH DROP

2"W DN & V RISE

1" D

C W

H

3/4" DCWH

2 1/2" DHWH(140)

2 1/2" DHWH(140)

1/

2" D

H W

H (1

TP MANIFOLD

3/4"DCWL DROP

(2)1/2"TP DN

TO FD'S

3/ 4"

D C

W H

(3)1/2"TP UP

TO MANIFOLD

TP MANIFOLD

3/4"DCWH DROP

(2)1/2"TP DN

TO FD'S

P-804 P-804

(2)2"V UP

SANITARY DRAINAGE PIPING

FROM FLOOR DRAINA

AT THE CONCOURSE

FOR CONTINUATION

REFER TO CONCORSE

DWGS.

4"W DN

10" OFD

6" R

L

" O

FD

6" RL

8" OFD

1/

4" D

H W

H

1/

2" D

H W

H (1

CHEMICAL DISPENSING

SYSTEM SEE DETAIL

ON DWG 0P508

DSP-1

CHEMICAL DISPENSING

SYSTEM SEE DETAIL

ON DWG OP508

DSP-1

4"RL UP TO

PLENUM DRAIN

4"RL UP TO

PLENUM DRAIN

4"RL DN

4"V UP

4" NG

1 1/2" DHWH 1 1/2" DHWH

2" DHWH

10"OFD UP

(7,400 SQ.FT.)

P-104A

(2)P-413

2"V DN & RISE

1-1/2"DCWL DROP

1-1/2"RPBP FOR

HVAC

4"FD-B

4" SAN (M.C.)

4" SAN (M.C.)

2" V

2"W UP

2"W UP

2" SAN (M.C.)

1/3"DCWH DROP

2"W DN&V RISE

1/2"DCWH DROP

2"W UP

8" R

L

4" RL

8" R

L

4" SAN (M.C.)

2"V UP

" O

FD

4" RL

" O

FD

1/

2" D

H W

H

1/

2" D

H W

L

1/

2" D

H W

H 3"

D C

W H

4" RL

02 E 02 D C

02 B

XA

02 H F.9

A.5

AA

AA.2

16.1

EJ

3.1

A

02 F

4" N

G

2 1/2" DHWH

2 1/2" DCWH

1" D

C W

H

2" DCWH

2" D

H W

H

3" D

C W

H

1/

2" D

H W

H (1

1/

2" D

H W

L

1/

2" D

H W

H

1/

2" D

C W

H

1/

4" D

H W

R H

(1

SL

1D

SS

4A

VS

4A

SV

4B

SS

4B

SS

4C

VS

4C

SS

4D

VS

4D

SS

4E

VS

4E

SS

4F

VS

4F

SS

4G

VS

4G

4" V 4" V

4" V

3" V

2" V

4" NG

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

08 P

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

2PL104-G

BLDG 2 FOURTH FLOOR PLUMBING PLAN - AREA G

RVD CADDFebruary 29, 2012

02629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING/ PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

1. ALL HORIZONTAL PIPING SHALL BE INSTALLED IN THE INTERSTITIAL

SPACE UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OWN ALL

REQUIRED CORING, SLEEVING, FIRESTOPPING, ETC. REFER TO

ARCHITECTURAL PLANS FOR INTERSITIAL SLAB CONSTRUCTION.

2. ALL DOMESTIC (POTABLE)AND NON DOMESTIC (NONPOTABLE) HOT,

COLD, AND HOT WATER CIRCULATION PIPING SHALL BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR IN ORDER TO MAINTAIN HOT WATER

TEMPERATURE TO ALL FIXTURES. IF PIPING CAN'T BE INSTALLED AT

THE INTERSTITIAL SPACE FLOOR, PIPING SHALL BE INSTALLED

BETWEEN THE INTERSTITIAL SPACE FLOOR AND THE CEILING AND THE

PIPING SHALL BE LOOPED TO ALLOW CONTINUOS HOT WATER

CIRCULATION.

3. ALL STACKS AND RISERS SHALL BE SUPPORTED AT THE INTERSTITIAL

SPACE FLOOR OR JUST ABOVE THE CEILING WHERE THE INTERSTIAL

SPACE DOES NOT EXIST. SEE DETAILS ON DWG 0P506.

4. PROVIDE A BALL VALVE IN THE OPEN POSITION WITH A LOCK AND CHAIN

AT ALL EMERGENCY SHOWERS

5. DRAIN VALVES SHALL BE PROVIDED AT THE BASE OF ALL PLUMBING

RISERS

6. ALL ISOLATION VALVES AT RISERS SHALL BE INSTALLED IN AN

ACCESSIBLE LOCATION, NO MORE THAN 12" ABOVE FINISHED CEILING

7. ALL MIXING VALVE AT SHOWERS SHALL HAVE THE TEMPATURE LIMIT

STOP ADJUSTED TO THE REQUIRED VA STANDARDS

GENERAL NOTES

REFER TO SKETCH:

SK-8-1-NJ-2-PL-104-G-1

REFER TO SKETCH:

SK-8-1-NJ-2-PL-104-G-1

RFI:01639 - Fixtures shall be type P-101

Correspondence No.

04924: Trap Primers have been deleted and Trap Guards Installed

Correspondence No.

04924: Trap Primers have been deleted and Trap Guards Installed

RFI 01809.1: DELETE (1) 4" FD-B's,

(1) P-804, (1) P-712, (1) RPBP for HVAC ((1) 4" FD-B to remain for humidifier and add (1) 4" OED)

RFI 01809.1:

DELETE (1) P-804,

(1) P-712 ((1) 4" FD-B t remain and add (1) 4" OED)

RFI 03032: Provide P-528 stainless steel sink.

15"

15"

SEE RFI 03553: Revises OFD piping to accomodate 12" Line from CON-A4

Re-routed out of column per PCO

811327, CO-07C

RFI 05524: Relocate plumbing lines out of the MCR

RFI 05524: Relocate plumbing lines out of the MCR

RFI 05524: Relocate plumbing lines out of the MCR

REFER TO SKETCH: nova Bulletin 040 Sketch - MCR plumbing revision - 2PL104-G

RFI 06587: P-609 fixture not required at this location

RFI 06587: P-609

fixture not required at this location

File details come from the government source that posted it. Updated .