SOW Attachment 11 _ Hazmat Information _ Jefferson Barracks _ Building 1_Part2 02.pdf

PDF 18 MB Posted

Attached to
C1DA--EHRM Infrastructure Upgrades Design- Jefferson Barracks (St. Louis) Federal contract opportunity
Solicitation number
36C77621R0087
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This pre-solicitation notice seeks statements of qualifications from firms for architect-engineering design services for infrastructure upgrades at the St. Louis VA Medical Center Jefferson Barracks Division. Firms should have experience in network infrastructure installation, renovations, upgrades including fiber optics, data cable, electrical systems, UPS, bonding, building management systems, HVAC, IT room renovations and data centers. The scope of work includes electrical, communication and security upgrades across multiple buildings. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses. Statements of qualifications are due by May 4, 2021 with discussions and written responses from shortlisted firms to follow. The design contract is expected to be awarded by June 30, 2021 for a 184-day period of performance.

View the file

Other files for this federal contract opportunity

Other files attached to C1DA--EHRM Infrastructure Upgrades Design- Jefferson Barracks (St. Louis), newest first.
File Type Posted
SOW Attachment 2 - VA OEHRM Site Infrastructure Requirements - 2.0.pdf PDF
SOW - Rvd - Supplement B - 05042021 - EHRM Infra JB.pdf PDF
SOW Attachment 32 - NCO 15 Form 10-6298 AE Fee Proposal Submission Form.zip ZIP file
36C77621R0087_3.docx DOCX document
36C77621R0087_2.docx DOCX document
Attachment - PPQ.docx DOCX document
SOW Attachment 33 - VA Form 10-6238 Construction Cost Estimate (1).zip ZIP file
SOW Attachment 26 _ Hazmat Information _ Jefferson Barracks _ Building 57.pdf PDF
SOW Attachment 24 _ Hazmat Information _ Jefferson Barracks _ Building 55.pdf PDF
SOW Attachment 28 _ Hazmat Information _ Jefferson Barracks _ Building 59.pdf PDF
SOW Attachment 25 _ Hazmat Information _ Jefferson Barracks _ Building 56.pdf PDF
SOW Attachment 23 _ Hazmat Information _ Jefferson Barracks _ Building 53T.pdf PDF
SOW Attachment 17 _ Hazmat Information _ Jefferson Barracks _ Building 24.pdf PDF
SOW Attachment 19 _ Hazmat Information _ Jefferson Barracks _ Building 51.pdf PDF
SOW Attachment 30 _ Hazmat Information _ Jefferson Barracks _ Building 60T.pdf PDF
SOW Attachment 27 _ Hazmat Information _ Jefferson Barracks _ Building 58.pdf PDF
SOW Attachment 33 - VA Form 10-6238 Construction Cost Estimate.zip ZIP file
SOW Attachment 18 _ Hazmat Information _ Jefferson Barracks _ Building 25.pdf PDF
SOW Attachment 16 _ Hazmat Information _ Jefferson Barracks _ Building 23.pdf PDF
SOW Attachment 21 _ Hazmat Information _ Jefferson Barracks _ Building 52.pdf PDF
SOW Attachment 31 _ Hazmat Information _ Jefferson Barracks _ Building 75.pdf PDF
SOW Attachment 29 _ Hazmat Information _ Jefferson Barracks _ Building 60.pdf PDF
SOW Attachment 22 _ Hazmat Information _ Jefferson Barracks _ Building 53.pdf PDF
SOW Attachment 20 _ Hazmat Information _ Jefferson Barracks _ Building 51T.pdf PDF
SOW Attachment 12 _ Hazmat Information _ Jefferson Barracks _ Building 2.pdf PDF
36C77621R0087.docx DOCX document
SOW Attachment 11 _ Hazmat Information _ Jefferson Barracks _ Building 1_Part2.pdf PDF
SOW Attachment 7 - VHA Directive 1013 Seasonal Influenza with Vaccines.pdf PDF
SOW - Supplement B - 03032021 - 657 21 701JB.pdf PDF
SOW Attachment 10 - Jefferson Barracks Campus Map.pdf PDF
SOW Attachment 4 - Sensitive Infrastructure Data Classification Memo.pdf PDF
SOW - Attachment 2 - VA OEHRM Site Infrastructure Req - 1.9.pdf PDF
SOW - Attachment 1 - VHA Required Div 01 Spec Sections.docx DOCX document
SOW Attachment 15 _ Hazmat Information _ Jefferson Barracks _ Building 18.pdf PDF
SOW Attachment 14 _ Hazmat Information _ Jefferson Barracks _ Building 3T.pdf PDF
SOW Attachment 13 _ Hazmat Information _ Jefferson Barracks _ Building 3.pdf PDF
SOW Attachment 9 - Jefferson Barracks - EHRM Building Plans_Part1.pdf PDF
SOW Attachment 8 - VHA Directive 1061.pdf PDF
SOW Attachment 6 - PG 18-15 AE Submission Reqts Vol C.doc DOC document
SOW Attachment 5 - EHRM Arch and Eng CPM Schedule Spec.docx DOCX document
SOW Attachment 3 - SOCAMES 6 Design Alert 1.pdf PDF
Show all 41

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ST. LOUIS V.A. MEDICAL CENTER

JEFFERSON BARRACKS DIVISION

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 1C102F-01-JB magnesia pipe lag 10 lf 0 4.00

1C102G-01-JB magnesia pipe lag 20 lf 0 4.00

1C105A-01-JB tar mudded joint fitting on fbglass 0 lf 3 8.00

H106-01-JB tar mudded joint fitting on fbglass 0 ea 8 8.00

H107-01-JB tar mudded joint fitting on fbglass 0 ea 4 4.00 H107-01-JB tar mudded joint fitting on fbglass 0 ea 7 8.00

30 22

Building 1 - Center - 1st Floor

TOTALS

1ST FLOOR – EAST WING

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 1E01-01-JB magnesia pipe lag 70 lf 0 4.00

1E01A-01-JB magnesia pipe lag 25 lf 0 4.00

1E02-01-JB magnesia pipe lag 20 lf 0 4.00 1E02-01-JB mudded joint ftg on fiberglas piping 0 ea 6 4.00

1E04-01-JB magnesia pipe lag 40 lf 0 4.00

1E05-01-JB magnesia pipe lag 6 lf 0 4.00 1E05-01-JB white canvas duct insulation 8 sf 0 0.00

1E07-01-JB magnesia pipe lag 20 lf 0 4.00

1E08-01-JB magnesia pipe lag 20 lf 0 4.00

1E09-01-JB magnesia pipe lag 40 lf 0 4.00

1E11-01-JB magnesia pipe lag 40 lf 0 4.00

1E11A-01-JB magnesia pipe lag 55 lf 0 4.00

1E12-01-JB magnesia pipe lag 45 lf 0 4.00

1E14-01-JB magnesia pipe lag 20 lf 0 4.00

1E15-01-JB magnesia pipe lag 20 lf 0 4.00

1E16-01-JB magnesia pipe lag 15 lf 0 4.00

1E17-01-JB magnesia pipe lag 30 lf 0 4.00

1E17A-01-JB magnesia pipe lag 40 lf 0 4.00

1E18-01-JB magnesia pipe lag 95 lf 0 4.00

1E19-01-JB magnesia pipe lag 85 lf 0 4.00

1E35-01-JB magnesia pipe lag 45 lf 0 4.00

1E39-01-JB magnesia pipe lag 75 lf 0 4.00

Building 1 - East - 1st Floor

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI H101-01-JB tar mudded joint fitting on fbglass 0 lf 24 4.00

H102-01-JB tar mudded joint fitting on fbglass 0 ea 5 4.00

H105-01-JB tar mudded joint fitting on fbglass 0 ea 20 4.00 H105-01-JB tar mudded joint fitting on fbglass 0 ea 21 8.00

814 76TOTALS

2ND FLOOR – WEST WING

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 2W01-01-JB tar mudded joint fitting on fibglass 0 lf 10 4.00

2W04-01-JB magnesia pipe lag 35 lf 0 4.00 2W04-01-JB mudded joint fitting on magnesia la 0 lf 5 4.00

2W05-01-JB tar mudded joint fitting on fibglass 0 lf 2 4.00

2W06-01-JB magnesia pipe lag 10 lf 0 4.00 2W06-01-JB mudded joint fitting on magnesia la 0 lf 6 4.00

2W18-01-JB magnesia pipe lag 60 lf 0 4.00 2W18-01-JB mudded joint fitting on magnesia la 0 lf 12 4.00

2W19-01-JB magnesia pipe lag 25 lf 0 4.00 2W19-01-JB mudded joint fitting on magnesia la 0 lf 8 4.00

2W21-01-JB cardboard wrap pipe lagging 30 lf 0 4.00 2W21-01-JB magnesia pipe lag 20 lf 0 4.00 2W21-01-JB mudded joint fitting on magnesia la 0 lf 6 4.00

2W22C-01-JB cardboard wrap pipe lagging 20 lf 0 4.00 2W22C-01-JB magnesia pipe lagging 26 lf 0 4.00 2W22C-01-JB mudded joint fitting on magnesia la 0 lf 10 4.00

2W25-01-JB mudded joint fitting on fbglass pip 0 sf 60 4.00 2W25-01-JB mudded joint fitting on fbglass pip 0 sf 10 6.00

2W27-01-JB magnesia pipe lagging 40 lf 0 4.00 2W27-01-JB mudded joint fitting on magnesia la 0 lf 12 4.00

2W28-01-JB magnesia pipe lagging 18 lf 0 4.00 2W28-01-JB mudded joint fitting on magnesia la 0 lf 8 4.00

2W29-01-JB magnesia pipe lagging 135 lf 0 4.00 2W29-01-JB mudded joint fitting on magnesia la 0 lf 42 4.00 2W29-01-JB tar mudded joint fitting on fibglass 0 sf 8 6.00

2W29A-01-JB magnesia pipe lagging 65 lf 0 4.00 2W29A-01-JB mudded joint fitting on magnesia la 0 lf 18 4.00

2W29B-01-JB magnesia pipe lagging 65 lf 0 4.00 2W29B-01-JB mudded joint fitting on magnesia la 0 lf 20 4.00

Building 1 - West - 2nd Floor

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI

2W29D-01-JB magnesia pipe lagging 30 lf 0 4.00 2W29D-01-JB mudded joint fitting on magnesia la 0 lf 16 4.00

2W32-01-JB magnesia pipe lagging 15 lf 0 4.00 2W32-01-JB mudded joint fitting on magnesia la 0 lf 6 4.00

2W33-01-JB magnesia pipe lagging 18 lf 0 4.00 2W33-01-JB mudded joint fitting on magnesia la 0 lf 5 4.00

2W35-01-JB magnesia pipe lagging 40 lf 0 4.00 2W35-01-JB mudded joint fitting on magnesia la 0 lf 17 4.00

H208-01-JB mudded joint fitting on fbglass pip 0 sf 2 4.00 H208-01-JB tar mudded joint fitting on fibglass 0 sf 8 6.00

H209-01-JB tar mudded joint fitting on fibglass 0 sf 42 6.00

H210-01-JB mudded joint fitting on fbglass pip 0 sf 18 4.00 H210-01-JB tar mudded joint fitting on fibglass 0 sf 44 6.00

652 395TOTALS

2ND FLOOR – CENTER SECTION

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 2C01-01-JB magnesia pipe lag 30 lf 0 4.00 2C01-01-JB mudded joint fitting on mag lag 0 lf 12 4.00

2C02-01-JB magnesia pipe lag 60 lf 0 4.00 2C02-01-JB mudded joint fitting on mag lag 0 lf 28 4.00

2C03-01-JB cardboard wrap pipe lagging 25 lf 0 2.00 2C03-01-JB magnesia pipe lag 60 lf 0 4.00 2C03-01-JB mudded joint fitting on mag lag 0 ea 20 4.00

2C05-01-JB cardboard wrap pipe lagging b.wall 11 lf 0 2.00 2C05-01-JB cardboard wrap pipe lagging b.wall 11 lf 0 4.00

2C07-01-JB cardboard wrap pipe lagging b.wall 11 lf 0 2.00

2C08-01-JB cardboard wrap pipe lagging b.wall 33 lf 0 2.00 2C08-01-JB cardboard wrap pipe lagging b.wall 11 lf 0 4.00

2C09-01-JB cardboard wrap pipe lagging b.wall 22 lf 0 2.00 2C09-01-JB cardboard wrap pipe lagging s.wall 33 lf 0 2.00

2C10-01-JB pipe lag on backwall 22 lf 0 2.00 2C10-01-JB pipe lag on backwall 22 lf 0 4.00 2C10-01-JB pipe lag on ceiling 12 lf 0 2.00 2C10-01-JB pipe lag on sidewall 6 lf 0 2.00 2C10-01-JB pipe lag on sidewall 4 lf 0 4.00

2C11-01-JB cardboard wrap pipe lagging 40 lf 0 4.00 2C11-01-JB magnesia pipe lag 15 lf 0 4.00 2C11-01-JB mudded joint fitting on mag lag 0 lf 12 4.00

2C12-01-JB cardboard wrap pipe lagging 28 lf 0 4.00 2C12-01-JB magnesia pipe lag 20 lf 0 4.00 2C12-01-JB mudded joint fitting on mag lag 0 lf 10 4.00

2C13-01-JB cardboard wrap pipe lagging 45 lf 0 4.00 2C13-01-JB magnesia pipe lag 30 lf 0 4.00 2C13-01-JB mudded joint fitting on mag lag 0 lf 15 4.00

2C14-01-JB cardboard wrap pipe lagging 25 lf 0 2.00 2C14-01-JB magnesia pipe lag 25 lf 0 4.00 2C14-01-JB mudded joint fitting on mag lag 0 lf 12 4.00

Building 1 - Center - 2nd Floor

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI

2C15-01-JB cardboard wrap pipe lagging 75 lf 0 2.00 2C15-01-JB magnesia pipe lag 20 lf 0 4.00 2C15-01-JB mudded joint fitting on mag lag 0 lf 8 4.00

2C16-01-JB cardboard wrap pipe lagging 50 lf 0 2.00

2C18-01-JB cardboard wrap pipe lagging 25 lf 0 2.00 2C18-01-JB magnesia pipe lag 20 lf 0 4.00 2C18-01-JB mudded joint fitting on fbglass pip 0 lf 28 4.00 2C18-01-JB mudded joint fitting on fbglass pip 0 lf 10 6.00 2C18-01-JB mudded joint fitting on mag lag 0 lf 8 4.00

2C19-01-JB cardboard wrap pipe lagging 70 lf 0 2.00 2C19-01-JB magnesia pipe lag 100 lf 0 4.00 2C19-01-JB mudded joint fitting on magnesia la 0 lf 35 4.00

2C29-01-JB cardboard wrap pipe lagging 8 lf 0 2.00 2C29-01-JB magnesia pipe lag 20 lf 0 4.00 2C29-01-JB mudded joint fitting on magnesia la 0 lf 8 4.00

H204-01-JB tar mudded joint fitting on fibglass 0 sf 20 6.00

H205-01-JB tar mudded joint fitting on fibglass 0 sf 20 6.00

989 246TOTALS

2ND FLOOR – EAST WING

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 2E04-01-JB mudded joint fitting on fbglass pip 0 lf 38 4.00 2E04-01-JB mudded joint fitting on fbglass pip 0 lf 11 6.00

2E05-01-JB magnesia pipe lag 25 lf 0 4.00 2E05-01-JB mudded joint fitting on magnesia la 0 lf 10 4.00

2E06-01-JB magnesia pipe lag 60 lf 0 4.00 2E06-01-JB mudded joint fitting on magnesia la 0 lf 16 4.00

2E09-01-JB magnesia pipe lag 40 lf 0 4.00 2E09-01-JB mudded joint fitting on magnesia la 0 lf 16 4.00

2E11-01-JB magnesia pipe lag 45 lf 0 4.00 2E11-01-JB mudded joint fitting on magnesia la 0 lf 6 4.00

2E12-01-JB magnesia pipe lag 10 lf 0 4.00 2E12-01-JB mudded joint fitting on magnesia la 0 lf 6 4.00

2E13-01-JB cardboard wrap pipe lagging 30 lf 0 4.00 2E13-01-JB magnesia pipe lag 20 lf 0 4.00 2E13-01-JB mudded joint fitting on magnesia la 0 lf 6 4.00

2E15-01-JB cardboard wrap pipe lagging 30 lf 0 4.00

2E17-01-JB cardboard wrap pipe lagging 15 lf 0 2.00 2E17-01-JB magnesia pipe lag 5 lf 0 4.00 2E17-01-JB mudded joint fitting on magnesia la 0 lf 3 4.00

2E18-01-JB magnesia pipe lag 20 lf 0 4.00

2E19-01-JB cardboard wrap pipe lagging 45 lf 0 2.00

2E20-01-JB magnesia pipe lag 30 lf 0 4.00

2E21-01-JB cardboard wrap pipe lagging 36 lf 0 2.00 2E21-01-JB magnesia pipe lag 40 lf 0 4.00 2E21-01-JB mudded joint fitting on magnesia la 0 lf 12 4.00

2E22-01-JB magnesia pipe lag 80 lf 0 4.00 2E22-01-JB mudded joint fitting on magnesia la 0 lf 32 4.00

2E23-01-JB cardboard wrap pipe lagging 65 lf 0 4.00

Building 1 - East - 2nd Floor

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 2E23-01-JB magnesia pipe lag 45 lf 0 4.00 2E23-01-JB mudded joint fitting on magnesia la 0 lf 10 4.00 2E23-01-JB tar mudded joint fitting on fibglass 0 lf 3 8.00

2E25A-01-JB magnesia pipe lag 50 lf 0 4.00 2E25A-01-JB mudded joint fitting on magnesia la 0 lf 30 4.00

2E26-01-JB cardboard wrap pipe lagging 50 lf 0 4.00 2E26-01-JB magnesia pipe lag 40 lf 0 4.00 2E26-01-JB mudded joint fitting on magnesia la 0 lf 18 4.00

2E27-01-JB magnesia pipe lag 45 lf 0 4.00 2E27-01-JB mudded joint fitting on magnesia la 0 lf 18 4.00

2E29-01-JB cardboard wrap pipe lagging 20 lf 0 4.00 2E29-01-JB magnesia pipe lag 35 lf 0 4.00 2E29-01-JB mudded joint fitting on magnesia la 0 lf 16 4.00

H201-01-JB tar mudded joint fitting on fibglass 0 sf 20 6.00

H202-01-JB cardboard wrap pipe lagging 40 lf 0 4.00

H203-01-JB tar mudded joint fitting on fibglass 0 sf 20 6.00

S201-01-JB magnesia pipe lagging 10 lf 0 4.00 S201-01-JB mudded joint fitting on magnesia la 0 lf 1 4.00 S201-01-JB tar wrap pipe lagging 10 lf 0 4.00

941 292TOTALS

3RD FLOOR – WEST WING

3RD FLOOR – CENTER SECTION

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 3C01-01-JB magnesia pipe lagging 10 lf 0 2.00

3C04-01-JB magnesia pipe lagging 15 lf 0 2.00

3C12-01-JB magnesia pipe lagging 11 lf 0 2.00 3C12-01-JB magnesia pipe lagging 11 lf 0 4.00

3C13-01-JB magnesia pipe lagging 22 lf 0 2.00

3C14-01-JB cardboard wrap pipe lagging 27 lf 0 2.00 3C14-01-JB mudded joint fitting on cardboard l 0 sf 5 2.00

3C15-01-JB magnesia pipe lagging 22 lf 0 2.00

3C17-01-JB magnesia pipe lagging 33 lf 0 2.00

3C18-01-JB magnesia pipe lagging 22 lf 0 2.00

H303-01-JB tar mudded joint fitting on fbglass 0 sf 16 6.00

H304-01-JB tar mudded joint fitting on fbglass 0 sf 25 6.00

H305-01-JB tar mudded joint fitting on fbglass 0 sf 10 6.00

173 56

Building 1 - Center - 3rd Floor

3RD FLOOR – EAST WING

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 3E06-01-JB tar mudded joint fitting on fbglass 0 lf 10 6.00

3E11-01-JB mudded joint fitting on fbglass 0 sf 42 4.00 3E11-01-JB mudded joint fitting on fbglass 0 sf 12 6.00

H301-01-JB mudded joint fitting on fbglass 0 sf 25 6.00

H302-01-JB mud patch on fibglass duct insula 25 sf 0 0.00 H302-01-JB tar mudded joint fitting on fbglass 0 sf 6 6.00

25 95

Building 1 - East - 3rd Floor

PENTHOUSE – CENTER SECTION

2008 THREE-YEAR REINSPECTION

THERMAL SYSTEM INSULATION (TSI) SUMMARY TABLE

Room # Description Qty S/LF Ftgs TH/DI 4C02-01-JB magnesia pipe lag 10 lf 0 4.00 4C02-01-JB mudded joint ftg on cardboard 0 ea 25 4.00 4C02-01-JB duct insulation 50 sf 0

4C03-01-JB magnesia pipe lag 2 lf 0 4.00 4C03-01-JB mudded joint ftg on cardboard 0 ea 5 4.00

4C03A-01-JB magnesia pipe lag 3 lf 0 4.00 4C03A-01-JB mudded joint ftg on cardboard 0 ea 5 4.00

65 35

Building 1 - Center - Penthouse

PENTHOUSE – EAST WING

Condition and Removal Priority Table

Qualitative Ranking Numerical Rating

Good 8, 9, 10

Fair 4, 5, 6, 7

Poor 1, 2, 3

Physical Disturbance Environmental Disturbance

Low 1, 2, 3

Medium 4, 5, 6, 7

High 8, 9, 10

Qualitative Ranking Numerical Rating High 1, 2, 3

Medium 4, 5, 6, 7

Low 8, 9, 10

1 Qualitative Rankings and Quantitative (Numerical) Ratings for Current Condition

2 Qualitative Rankings and Quantitative (Numerical) Ratings for Potential for Disturbance

Assessment FactorsQualitative Ranking Numerical Rating

Description of Current Condition Surfacing material has no visible damage or small amounts of damage; covering on thermal system insulation is intact or has small amounts of damage; miscellaneous materials intact; no visible debris or small amounts of debris.

Address with on-going maintenance procedures

Maintain in good condition

Surfacing material has moderate but not extensive amounts of visible damage; covering on thermal system insulation is cut or torn, exposing moderate but not extensive amounts of insulation; moderate but not extensive damage to miscellaneous materials such as floor tile; moderate but not extensive amounts of visible dust and debris..

3 Qualitative Rankings and Quantitative (Numerical) Ratings for Removal Priority

Description of Current Condition Address short-term

Extensive damage to surfacing material; covering on thermal system insulation is cut or torn extensively and insulation itself is damage; miscellaneous materials such as floor tile extensively damaged and underlying mastic exposed; extensive amounts of dust and debris.

Accessibility: accessibility during normal operations

Activities: activities that people do and how often they do them

Vibration: vibration from operating machinery, HVAC equipment, and so forth

Air/Dust: air currents strong enough to dislodge loose ACM; airborne dust that can erode material

Corrosive: corrosive atmosphere or liquids that can erode the covering or matrix

Water Damage: water damage from leaking roof, pipe or other source

ST. LOUIS V. A. MEDICAL CENTER

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Rating Based On Rating Based On

HMA-01 1 Basement 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 Basement Flooring Adhesive No No 10 Intact 1 Access 9

HMA-03 1 Basement 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-08 1 Basement Transite Panels No No 10 Intact 1 Access 9

HMA-09 1 Basement Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 Basement Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-12 1 Basement White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-13 1 3 Duct Insulation No No 10 Intact 1 Maintenance 9

HMA-15 1 Basement Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-01 1 Basement 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 Basement Flooring Adhesive No No 10 Intact 1 Access 9

HMA-03 1 Basement 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-04 1 Basement 9"x9" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-08 1 Basement Transite Panels No No 10 Intact 1 Access 9

Material Description Removal Priority 3

Building 1 - Basement - Center Section

Current Condition 1

Building 1 - Basement - West Wing

Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Material Description Removal Priority 3

Current Condition 1Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

HMA-09 1 Basement Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 Basement Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-13 1 3 Duct Insulation No No 10 Intact 1 Maintenance 9

HMA-15 1 Basement Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-21 1 Basement Tank Insulation Yes No 7 Damage 2 Maintenance 6

HMA-01 1 Basement 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 Basement Flooring Adhesive No No 10 Intact 1 Access 9

HMA-05 1 Basement Linoleum No Yes 10 Intact 2 Floor Maintenance 7

HMA-09 1 Basement Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 Basement Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-11 1 Basement Pipe Hangers Yes No 7 Damage 2 Access 6

HMA-12 1 Basement White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-15 1 Basement Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-16 1 Basement Felt Roofing Tar No No 10 Intact 1 Maintenance 10

HMA-17 1 Basement Gray Reflective Paper No No 9 Intact 1 Access 10

Building 1 - Basement - East Wing

Building 1 - 1st Floor - West Wing

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Material Description Removal Priority 3

Current Condition 1Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

HMA-01 1 1 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-03 1 1 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-04 1 1 9"x9" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-06 1 1 12"x12" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-09 1 1 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 1 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-12 1 1 White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-02 1 1 Flooring Adhesive No No 10 Intact 1 Access 9

HMA-03 1 1 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-09 1 1 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 1 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-01 1 1 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-03 1 1 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-04 1 1 9"x9" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-06 1 1 12"x12" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

Building 1 - 1st Floor - East Wing

Building 1 - 1st Floor - Center Section

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Material Description Removal Priority 3

Current Condition 1Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

HMA-09 1 1 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 1 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-12 1 1 White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-15 1 1 Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-02 1 2 Flooring Adhesive No No 10 Intact 1 Access 9

HMA-05 1 2 Linoleum No Yes 10 Intact 2 Floor Maintenance 7

HMA-09 1 2 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 2 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-15 1 2 Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-01 1 2 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 2 Flooring Adhesive No No 10 Intact 1 Access 9

HMA-03 1 2 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-04 1 2 9"x9" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-06 1 2 12"x12" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-08 1 2 Transite Panels No No 10 Intact 1 Access 9

Building 1 - 2nd Floor - West Wing

Building 1 - 2nd Floor - Center Section

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Material Description Removal Priority 3

Current Condition 1Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

HMA-09 1 2 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 2 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-12 1 2 White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-15 1 2 Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-18 1 2 Lab Counter Tops No Yes 10 Intact 1 Maintenance 10

HMA-19 1 2 Transite Vent Hood No No 10 Intact 1 Access 9

HMA-02 1 2 Flooring Adhesive No No 10 Intact 1 Access 9

HMA-04 1 2 9"x9" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-07 1 2 Linoleum & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-08 1 2 Transite Panels No No 10 Intact 1 Access 9

HMA-09 1 2 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 2 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-12 1 2 White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-15 1 2 Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-03 1 3 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

Building 1 - 2nd Floor - East Wing

Building 1 - 3rd Floor - West Wing

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Material Description Removal Priority 3

Current Condition 1Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

HMA-04 1 3 9"x9" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-05 1 3 Linoleum No Yes 10 Intact 2 Floor Maintenance 7

HMA-06 1 3 12"x12" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-09 1 3 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-15 1 3 Fire Doors (Assumed) No Restricted 10 Intact 1 Maintenance 10

HMA-01 1 3 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 3 Flooring Adhesive No No 10 Intact 1 Access 9

HMA-03 1 3 12"x12" Floor Tile & Adhesive No Yes 10 Intact 2 Floor Maintenance 7

HMA-09 1 3 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 3 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-18 1 3 Lab Counter Tops No Yes 10 Intact 1 Maintenance 10

HMA-19 1 3 Transite Vent Hood No No 10 Intact 1 Access 9

HMA-01 1 3 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 3 Flooring Adhesive No No 10 Intact 1 Access 9

HMA-06 1 3 12"x12" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

Building 1 - 3rd Floor - East Wing

Building 1 - 3rd Floor - Center Section

2008 THREE-YEAR ASBESTOS REINSPECTION

CONDITION AND REMOVAL PRIORITY TABLE

Material Description Removal Priority 3

Current Condition 1Friable Yes/No

Accessibility Yes/No

Restricted

Potential for Disturbance 2

Homogeneous Area No. Bldg Floor

HMA-09 1 3 Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 3 Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-13 1 3 Duct Insulation No No 10 Intact 1 Maintenance 9

HMA-12 1 3 White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-18 1 3 Lab Counter Tops No Yes 10 Intact 1 Maintenance 10

HMA-19 1 3 Transite Vent Hood No No 10 Intact 1 Access 9

HMA-01 1 Penthouse 9"x9" Floor Tile No Yes 10 Intact 2 Floor Maintenance 7

HMA-02 1 Penthouse Flooring Adhesive No No 10 Intact 1 Access 9

HMA-09 1 Penthouse Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-10 1 Penthouse Pipe Insulation & Fittings Yes No 7 Damage 2 Access 6

HMA-12 1 Penthouse White Duct Connector (Vibration Isolator) No No 10 Intact 1 Access 10

HMA-13 1 3 Duct Insulation No No 10 Intact 1 Maintenance 9

HMA-09 1 Penthouse Tan Exterior Coating No Yes 9 Condition 2 Accessibility 9

HMA-14 1 Penthouse Thermal Insulation Debris Yes Yes 5 Debris 7 Accessibility 6

HMA-20 1 Penthouse Roofing Mastic No No 10 Intact 1 Access 10

Building 1 - Penthouse - East Wing

Building 1 - Penthouse - Center Section

Master Summary Table Asbestos Bulk Samples

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

JB01 00 GC03 JB-01-00-M-GC03-23 4x8 perforated panels cement asbestos board JB01 00 GC10A JB-01-00-M-GC10-57 2x2 gray pin & gouge ceiling tile JB01 00 GC10A JB-01-00-M-GC10A-53 4" black cove base JB01 00 GC10A JB-01-00-M-GC10A-54 2x2 gray worm & pin ceiling tile JB01 00 GC17 JB-01-00-M-GC17-09 Black condensate wrap JB01 00 GC17 JB-01-00-M-GC17-50 White gypsum drywall JB01 00 GC17A JB-01-00-M-GC17A-39 2x4 gray large & small pin ceiling tile JB01 00 GC17A JB-01-00-M-GC17A-40 2x4 gray pin pattern ceiling tile JB01 00 GC17A JB-01-00-M-GC17A-41 2x4 gray pin & jagged worm ceiling tile JB01 00 GE01 JB-01-00-M-GE01-26 Gray reflective paper JB01 00 GE22 JB-01-00-M-GE22-18 Brown speckled linoleum JB01 00 GE26 JB-01-00-M-GE26-01A Black other JB01 00 GE29 JB-01-00-M-GE29-25 2x2 gray worm & gouge ceiling tile JB01 00 GE31 JB-01-00-M-GE31-24 2x2 white w/pin pattern ceiling tile JB01 00 GE32 JB-01-00-M-GE32-55 2x2 gray jagged worm & pin ceiling tile JB01 00 GE32 JB-01-00-M-GE32-56 6" black cove base JB01 00 GW13 JB-01-00-M-GW13-58 2x4 gray pin & gouge ceiling tile JB01 00 GW13 JB-01-00-M-GW13-61 2x4 gray pin & angle worms ceiling tile JB01 00 GW14 JB-01-00-M-GW14-62 2x4 gray random worm & gouge ceiling tile JB01 00 H003 JB-01-00-M-H003-33 4" beige cove base JB01 00 H004 JB-01-00-M-H004-21 4" brown cove base JB01 00 H009 JB-01-00-M-H009-45 2" gray cove base JB01 00 H009 JB-01-00-M-H009-46 2x4 gray worm & pin ceiling tile JB01 00 H009 JB-01-00-M-H009-47 2x4 gray rough worm & pin ceiling tile JB01 00 S001 JB-01-00-M-S001-22 Beige stair tread JB01 00 GC17 JB-01-00-S-GC17-15 Off-white hardwall plaster JB01 00 GC02 JB-01-00-T-GC02-37 Gray TSI JB01 00 GC02 JB-01-00-T-GC02-38 Gray TSI JB01 00 GC17 JB-01-00-T-GC17-13 Gray mudded joint fitting on tar wrap JB01 00 GC17 JB-01-00-T-GC17-14 Black/off-white tar wrap pipe lagging JB01 00 GC17 JB-01-00-T-GC17-51 Brown/off-white TSI JB01 00 GC17 JB-01-00-T-GC17-52 Gray TSI JB01 00 GC17A JB-01-00-T-GC17A-10 Gray mudded joint fitting on cardboard lagging JB01 00 GC17A JB-01-00-T-GC17A-11 Brown cardboard wrap pipe lagging JB01 00 GC18 JB-01-00-T-GC18-07 Gray mudded joint fitting on magnesia pipe lagging JB01 00 GC18 JB-01-00-T-GC18-08 Off-white magnesia pipe lagging JB01 00 GC18 JB-01-00-T-GC18-12 Off-white mudded joint fitting on fiberglass JB01 00 GC22 JB-01-00-T-GC22-01 Gray tank #1 insulation JB01 00 GC22 JB-01-00-T-GC22-02 Amber/gray TSI JB01 00 GC22 JB-01-00-T-GC22-03 Amber/gray TSI JB01 00 GC22 JB-01-00-T-GC22-04 Gray tank #2 insulation JB01 00 GC22 JB-01-00-T-GC22-05 Gray TSI JB01 00 GC22 JB-01-00-T-GC22-06 Gray TSI JB01 00 GE07 JB-01-00-T-GE07-27 White canvas duct connector (woven) JB01 00 GE07 JB-01-00-T-GE07-28 Gray/off-white TSI

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

1994 Initial Asbestos Inspection

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 00 GE07 JB-01-00-T-GE07-31 Gray TSI JB01 00 GE07 JB-01-00-T-GE07-32 Gray TSI JB01 00 GE26 JB-01-00-T-GE26-16 Gray aircell pipe lagging JB01 00 GE26 JB-01-00-T-GE26-17 Gray mudded joint fitting on aircell lagging JB01 00 GW03 JB-01-00-T-GW03-42 White TSI JB01 00 GW03 JB-01-00-T-GW03-43 Gray TSI JB01 00 GW03 JB-01-00-T-GW03-44 White TSI JB01 00 GW13 JB-01-00-T-GW13-59 Brown TSI JB01 00 GW13 JB-01-00-T-GW13-60 White TSI JB01 00 GW18 JB-01-00-T-GW18-48 Gray TSI JB01 00 GW18 JB-01-00-T-GW18-49 Gray TSI JB01 00 H001 JB-01-00-T-H001-29 Off-white/yellow TSI JB01 00 H001 JB-01-00-T-H001-30 White canvas duct insulation JB01 00 H003 JB-01-00-T-H003-34 Brown TSI JB01 00 H003 JB-01-00-T-H003-35 Gray TSI JB01 00 H003 JB-01-00-T-H003-36 Gray TSI JB01 00 H004 JB-01-00-T-H004-19 Off-white TSI JB01 00 H004 JB-01-00-T-H004-20 Gray TSI JB01 01 1W02 JB-01-01-1W02-42 White mudded joint fitting on fiberglass lagging JB01 01 1C102F JB-01-01-M-1C102F-35 White ceiling tile JB01 01 1C106 JB-01-01-M-1C106-45 2x4 gray pin & jagged worm ceiling tile JB01 01 1C115 JB-01-01-M-1C115-20 2x4 gray worm & pin ceiling tile JB01 01 1C123 JB-01-01-M-1C123-22 Black ceiling tile mastic JB01 01 1C125 JB-01-01-M-1C125-01A Black other JB01 01 1C125 JB-01-01-M-1C125-26 White/brown gypsum drywall JB01 01 1E07 JB-01-01-M-1E07-34 2x2 gray rough worm & pin ceiling tile JB01 01 1E17 JB-01-01-M-1E17-44 2x2 gray worm & pin ceiling tile JB01 01 1E17 JB-01-01-M-1E17-46 2x2 gray jagged & pin ceiling tile JB01 01 1E17 JB-01-01-M-1E17-47 4" brown cove base JB01 01 1E35 JB-01-01-M-1E35-04 Gray reflective paper JB01 01 1W08A JB-01-01-M-1W08-18 2" brown cove base JB01 01 1W08A JB-01-01-M-1W08A-16 2" black cove base JB01 01 1W11 JB-01-01-M-1W11-25 1x1 off-white fissure ceiling tile JB01 01 1W15 JB-01-01-M-1W15-21 1x1 gray pin & peck ceiling tile JB01 01 1W18 JB-01-01-M-1W18-06 6" black cove base JB01 01 1W20 JB-01-01-M-1W20-15 2x2 gray random peck ceiling tile JB01 01 1W24 JB-01-01-M-1W24-27 Blue cove base JB01 01 1W26 JB-01-01-M-1W26-17 1x1 off-white moon crater ceiling tile JB01 01 H101 JB-01-01-M-H101-48 2x2 gray pin & gouge ceiling tile JB01 01 H102 JB-01-01-M-H102-03 2" gray cove base JB01 01 H106 JB-01-01-M-H106-43 2x2 off-white worm & random gouge ceiling tile JB01 01 H107 JB-01-01-M-H107-29 4" gray cove base JB01 01 H107 JB-01-01-M-H107-30 2x2 off-white rough ceiling tile JB01 01 H112 JB-01-01-M-H112-24 2x4 gray rough worm & pin ceiling tile JB01 01 H116 JB-01-01-M-H116-13 2" beige cove base JB01 01 H117 JB-01-01-M-H117-19 4" beige cove base

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 01 H119 JB-01-01-M-H119-14 2x4 gray pin & peck ceiling tile JB01 01 S101 JB-01-01-M-S101-05 Beige stair tread JB01 01 S101 JB-01-01-M-S101-28 4" black cove base JB01 01 1E05 JB-01-01-S-1E05-36 White/gray hardwall plaster JB01 01 1C105A JB-01-01-T-1C105A-39 Black/yellow TSI JB01 01 1E01 JB-01-01-T-1E01-08 White TSI JB01 01 1E01 JB-01-01-T-1E01-10 Gray mudded joint fitting on magnesia pipe lagging JB01 01 1E05 JB-01-01-T-1E05-31 White duct insulation JB01 01 1E05 JB-01-01-T-1E05-32 Gray TSI JB01 01 1E05 JB-01-01-T-1E05-40 White TSI JB01 01 1E05 JB-01-01-T-1E05-41 Off-white TSI JB01 01 1E17 JB-01-01-T-1E17-09 White TSI JB01 01 1E17 JB-01-01-T-1E17-12 Gray TSI JB01 01 1W02 JB-01-01-T-1W02-23 White canvas duct connector (woven) JB01 01 1W02 JB-01-01-T-1W02-33 Off-white/gray TSI JB01 01 1W20 JB-01-01-T-1W20-07 White magnesia pipe lagging JB01 01 1W20 JB-01-01-T-1W20-11 Gray TSI JB01 01 H101 JB-01-01-T-H101-37 Black/brown mudded joint fitting on fiberglass JB01 01 H101 JB-01-01-T-H101-38 Black/yellow TSI JB01 01 H105 JB-01-01-T-H105-01 Black condensate wrap JB01 01 H105 JB-01-01-T-H105-02 Brown canvas duct connector JB01 02 2E04 JB-01-02-T-2E04-16 Gray TSI JB01 02 2C04 JB-01-02-M-2C04-39 4" green cove base JB01 02 2C04 JB-01-02-M-2C04-40 4" olive cove base JB01 02 2C10 JB-01-02-M-2C10-43 4'x8' white perforated panels JB01 02 2C12 JB-01-02-M-2C12-41 Black acoustical panels JB01 02 2E05 JB-01-02-M-2E05-38 2x4 gray giant worm & pin ceiling tile JB01 02 2E17 JB-01-02-M-2E17-30 2x4 gray pin pattern ceiling tile JB01 02 2E18 JB-01-02-M-2E18-34 2x2 gray pin & peck ceiling tile JB01 02 2E20 JB-01-02-M-2E20-29 Gray ceiling tile JB01 02 2W15 JB-01-02-M-2W15-47 4" brown cove base JB01 02 2W22C JB-01-02-M-2W22C-27 White/brown gypsum drywall JB01 02 2W32 JB-01-02-M-2W32-49 Gray ceiling tile JB01 02 2W33 JB-01-02-M-2W33-48 6" beige cove base JB01 02 2E11 JB-01-02-M-2E11-32 Gray ceiling tile JB01 02 H201 JB-01-02-M-H201-28 2x2 gray worm & pin ceiling tile JB01 02 H202 JB-01-02-M-H202-35 4" gray cove base JB01 02 H203 JB-01-02-M-H203-31 2x2 off-white pin & gouge ceiling tile JB01 02 H203 JB-01-02-M-H203-33 Gray speckled linoleum JB01 02 H205 JB-01-02-M-H205-45 4" white cove base JB01 02 H205 JB-01-02-M-H205-46 2x2 gray random worm & gouge ceiling tile JB01 02 S201 JB-01-02-M-S201-36 Beige stair tread JB01 02 S202 JB-01-02-M-S202-42 2" black cove base JB01 02 2W29 JB-01-02-S-2W29-26 Off-white hardwall plaster JB01 02 2C15 JB-01-02-T-2C15-02 White TSI JB01 02 2C15 JB-01-02-T-2C15-05 White mudded joint fitting on magnesia lagging

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 02 2C15 JB-01-02-T-2C15-08 Gray/black TSI JB01 02 2C15 JB-01-02-T-2C15-11 Gray/off-white TSI JB01 02 2C18 JB-01-02-T-2C18-17 White mudded joint fitting on fiberglass JB01 02 2C18 JB-01-02-T-2C18-20 Yellow/white TSI JB01 02 2E04 JB-01-02-T-2E04-19 White canvas duct insulation JB01 02 2E29 JB-01-02-T-2E29-03 White TSI JB01 02 2E29 JB-01-02-T-2E29-06 Gray TSI JB01 02 2E29 JB-01-02-T-2E29-12 Gray TSI JB01 02 2W21 JB-01-02-T-2W21-07 Gray/black cardboard wrap pipe lagging JB01 02 2W21 JB-01-02-T-2W21-10 Gray mudded joint fittings on cardboard JB01 02 2W25 JB-01-02-T-2W25-18 Gray TSI JB01 02 2W25 JB-01-02-T-2W25-21 Yellow/white TSI JB01 02 2W25 JB-01-02-T-2W25-37 White canvas duct connector (woven) JB01 02 2W29 JB-01-02-T-2W29-01 White magnesia pipe lagging JB01 02 2W29 JB-01-02-T-2W29-04 Gray TSI JB01 02 2W29 JB-01-02-T-2W29-24 Black/yellow TSI JB01 02 H209 JB-01-02-T-H209-22 Yellow/black tar mudded joint fitting on fiberglass JB01 02 H210 JB-01-02-T-H210-23 Black/yellow TSI JB01 02 S201 JB-01-02-T-S201-13 Brown/black TSI JB01 02 S201 JB-01-02-T-S201-14 Brown/black tar wrap pipe lagging JB01 02 S201 JB-01-02-T-S201-15 Brown/black TSI JB01 02 H205 JB-01-2-M-H205-44 4" beige cove base JB01 02 2E29 JB-02-02-T-2E29-09 Gray TSI JB01 02 2E27 JB-01-02-M-2E27-25 4" black cove base JB01 03 3C09 JB-01-03-M-3C09-41 4" brown cove base JB01 03 3C11 JB-01-03-M-3C11-40 2" black cove base JB01 03 3C26 JB-01-03-M-3C26-44 2x4 gray worm & pin ceiling tile JB01 03 3E05 JB-01-03-M-3E05-28 4" black cove base JB01 03 3E06A JB-01-03-M-3E06A-27 2x4 gray pin & angle worms ceiling tile JB01 03 3E09 JB-01-03-M-3E09-29 2x4 gray pin & gouge ceiling tile JB01 03 3E09 JB-01-03-M-3E09-30 4" gray cove base JB01 03 E311 JB-01-03-M-E311-26 Off-white gypsum drywall JB01 03 E311 JB-01-03-M-E311-33 2x4 gray pin & peck ceiling tile JB01 03 E313 JB-01-03-M-E313-34 4" light gray cove base JB01 03 H301 JB-01-03-M-H301-36 2x2 gray random worm & gouge ceiling tile JB01 03 H301 JB-01-03-M-H301-37 2x2 gray pin & gouge ceiling tile JB01 03 H301 JB-01-03-M-H301-38 2x2 gray rough worm & pin ceiling tile JB01 03 H303 JB-01-03-M-H303-39 2x2 gray worm & pin ceiling tile JB01 03 H303 JB-01-03-M-H303-42 2x2 gray pin & peck ceiling tile JB01 03 H304 JB-01-03-M-H304-43 Off-white cove base JB01 03 W314 JB-01-03-M-W314-01A Black rubberized duct connector JB01 03 W314 JB-01-03-M-W314-45 Gray other JB01 03 3C04 JB-01-03-T-3C04-19 Gray/white cardboard wrap pipe lagging JB01 03 3C04 JB-01-03-T-3C04-22 White mudded joint fitting on cardboard lagging JB01 03 3C12 JB-01-03-T-3C12-13 White magnesia pipe lagging JB01 03 3C13 JB-01-03-T-3C13-14 White TSI

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 03 3C13 JB-01-03-T-3C13-15 White TSI JB01 03 3C13 JB-01-03-T-3C13-16 Gray mudded joint fitting on magnesia pipe lagging JB01 03 3C13 JB-01-03-T-3C13-17 Gray TSI JB01 03 3C13 JB-01-03-T-3C13-18 Gray TSI JB01 03 3C14 JB-01-03-T-3C14-20 Gray TSI JB01 03 3C14 JB-01-03-T-3C14-23 Gray TSI JB01 03 3C18 JB-01-03-T-3C18-21 Gray TSI JB01 03 3C18 JB-01-03-T-3C18-24 Gray TSI JB01 03 3E03 JB-01-03-T-3E03-10 Black/orange tar on fiberglass duct insulation JB01 03 3E06 JB-01-03-T-3E06-02 Black/yellow TSI JB01 03 3E11 JB-01-03-T-3E11-04 White canvas duct insulation JB01 03 3E11 JB-01-03-T-3E11-05 Green/white TSI JB01 03 3E11 JB-01-03-T-3E11-06 White/gray TSI JB01 03 3E11 JB-01-03-T-3E11-07 White mudded joint fitting on fiberglass JB01 03 3E11 JB-01-03-T-3E11-08 White TSI JB01 03 3E11 JB-01-03-T-3E11-09 White TSI JB01 03 3E11 JB-01-03-T-3E11-31 Gray TSI JB01 03 H302 JB-01-03-T-H302-11 Black/orange TSI JB01 03 H302 JB-01-03-T-H302-12 Black/yellow TSI JB01 03 H302 JB-01-03-T-H302-35 Gray/orange mud patch on fiberglass duct insulation JB01 03 H304 JB-01-03-T-H304-01 Black/yellow tar mudded joint fitting on fiberglass JB01 03 H305 JB-01-03-T-H305-03 Black/yellow TSI JB01 03 3E12 JB-03-S-3E12-25 White/off-white hardwall plaster JB01 04 4C02B JB-01-04-M-4C02B-01A Black rubberized duct connector JB01 04 4E01B JB-01-04-M-4E01B-19 Black tar covering JB01 04 S402 JB-01-04-M-S402-14 White gypsum drywall JB01 04 4C03A JB-01-04-S-4C03-13 Off-white hardwall plaster JB01 04 4C02 JB-01-04-T-4C02-04 Off-white mudded joint fitting on fiberglass lagging JB01 04 4C02 JB-01-04-T-4C02-05 White TSI JB01 04 4C02 JB-01-04-T-4C02-06 White unknown JB01 04 4C02 JB-01-04-T-4C02-07 White canvas duct insulation JB01 04 4C02 JB-01-04-T-4C02-08 White/gray TSI JB01 04 4C02 JB-01-04-T-4C02-09 Yellow/white TSI JB01 04 4C02 JB-01-04-T-4C02-15 White canvas duct connector (woven) JB01 04 4C02 JB-01-04-T-4C02-17 Green canvas duct connector JB01 04 4C02 JB-01-04-T-4C02-18 Brown canvas duct connector JB01 04 4C03A JB-01-04-T-4C03A-01 White magnesia pipe lagging JB01 04 4C03A JB-01-04-T-4C03A-02 White TSI JB01 04 4C03A JB-01-04-T-4C03A-03 White TSI JB01 04 4E01B JB-01-04-T-4E01B-10 White/orange debris from thermal insulation JB01 04 4E01B JB-01-04-T-4E01B-11 White TSI JB01 04 4E01B JB-01-04-T-4E01B-12 Gray TSI JB01 04 4W01 JB-01-04-T-4W01-16 Lightweight white canvas duct connector

JB01 00 GW13 JB-01-00-F-GW13-001A Gray 12x12 floor tile, black mastic JB01 00 GW13 JB-01-00-S-GW13-002A Gray transite peg board wall panel

2008 Asbestos Reinspection

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 00 GW15 JB-01-00-F-GW15-003A Gray 12x12 floor tile, black mastic JB01 00 GW17 JB-01-00-F-GW17-004A Layer 1 - Brown 9x9 floor tile JB01 00 GW17 JB-01-00-F-GW17-004A Layer 2 - Black mastic JB01 00 GW02 JB-01-00-F-GW02-005A Layer 1 - Brown 9x9 floor tile JB01 00 GW02 JB-01-00-F-GW02-005A Layer 2 - Black mastic JB01 00 GW01 JB-01-00-F-GW01-006A Layer 1 - Brown 9x9 floor tile JB01 00 GW01 JB-01-00-F-GW01-006A Layer 2 - Black mastic JB01 00 GW10A JB-01-00-F-GW10A-007A Gray 12x12 floor tile, black mastic JB01 00 GW03 JB-01-00-M-GW03-008A White vibration isolator JB01 00 GW03 JB-01-00-T-GW03-009A White TSI wrapping on duct JB01 00 GW04B JB-01-00-F-GW04B-010A Green 12x12 floor tile, black mastic JB01 00 H010 JB-01-00-F-H010-011A White 12x12 floor tile, black mastic JB01 00 GC17A JB-01-00-F-GC17A-012A Layer 1 - Dark white 9x9 floor tile JB01 00 GC17A JB-01-00-F-GC17A-012A Layer 2 - Black mastic JB01 00 GC17C JB-01-00-F-GC17C-013A Layer 1 - Brown 9x9 floor tile JB01 00 GC17C JB-01-00-F-GC17C-013A Layer 2 - Black mastic JB01 00 GC17 JB-01-00-F-GC17-014A Tan 12x12 floor tile, yellow mastic, black mastic JB01 00 GC17 JB-01-00-F-GC17-015A Layer 1 - Brown 9x9 floor tile JB01 00 GC17 JB-01-00-F-GC17-015A Layer 2 - Black mastic JB01 00 GC01 JB-01-00-F-GC01-016A Light gray 12x12 floor tile, yellow mastic, black mastic JB01 00 GC02 JB-01-00-F-GC02-017A Black felt, black mastic JB01 00 GC01 JB-01-00-M-GC01-018A White vibration isolator JB01 00 GC01 JB-01-00-M-GC01-019A White vibration isolator JB01 00 GC03 JB-01-00-F-GC03-020A Gray 12x12 floor tile, black mastic JB01 00 H006 JB-01-00-F-H006-021A White 12x12 floor tile, yellow mastic, black mastic JB01 00 H006 JB-01-00-F-H006-022A White 12x12 floor tile, black mastic JB01 00 GC14 JB-01-00-F-GC14-023A Layer 1 - Gray 9x9 floor tile JB01 00 GC14 JB-01-00-F-GC14-023A Layer 2 - Black mastic JB01 00 GC15 JB-01-00-F-GC15-024A Dark brown 9x9 floor tile, black mastic JB01 00 GC15 JB-01-00-F-GC15-025A Tan 9x9 floor tile, black mastic JB01 00 GC12 JB-01-00-F-GC12-026A White 12x12 floor tile, black mastic JB01 00 GC12 JB-01-00-F-GC12-027A Layer 1 - Dark gray 9x9 floor tile JB01 00 GC12 JB-01-00-F-GC12-027A Layer 2 - Black mastic JB01 00 GC11 JB-01-00-F-GC11-028A Layer 1 - White 12x12 floor tile JB01 00 GC11 JB-01-00-F-GC11-028A Layer 2 - Black mastic JB01 00 GC11 JB-01-00-F-GC11-028A Layer 3 - Yellow mastic JB01 00 GC09 JB-01-00-F-GC09-029A Layer 1 - Brown 12x12 floor tile JB01 00 GC09 JB-01-00-F-GC09-029A Layer 2 - Black mastic JB01 00 GE19 JB-01-00-F-GE19-030A Layer 1 - Brown 12x12 floor tile JB01 00 GE19 JB-01-00-F-GE19-030A Layer 2 - Black mastic JB01 00 H004 JB-01-00-F-H004-031A Layer 1 - Brown 12x12 floor tile JB01 00 H004 JB-01-00-F-H004-031A Layer 2 - Black mastic JB01 00 GE18C JB-01-00-S-GE18C-032A Tan textured material JB01 00 GE18 JB-01-00-M-GE18-033A Felt, roofing tar JB01 00 GE04 JB-01-00-F-GE04-034A Layer 1 - Brown 9x9 floor tile JB01 00 GE04 JB-01-00-F-GE04-034A Layer 2 - Black mastic

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 00 GE05 JB-01-00-F-GE05-035A Black mastic JB01 00 GE09 JB-01-00-F-GE09-036A Layer 1 - Dark brown 9x9 floor tile JB01 00 GE09 JB-01-00-F-GE09-036A Layer 2 - Black mastic JB01 00 GE10 JB-01-00-F-GE10-037A Tan 12x12 floor tile, yellow mastic

JB01 00 H001 JB-01-00-T-H001-038A 6" horizontal - white wrap, foil backing, yellow fiberglass pipe insulation

JB01 00 H001 JB-01-00-T-H001-039A 6" horizontal pipe hanger - white wrap, foil backing, yellow fiberglass pipe insulation

JB01 00 GC17 JB-01-00-F-GC17E-040A Layer 1 - Dark white 9x9 floor tile JB01 00 GC17 JB-01-00-F-GC17E-040A Layer 2 - Black mastic JB01 00 GW09 JB-01-00-F-GW09-041A Layer 1 - Light white 12x12 floor tile JB01 00 GW09 JB-01-00-F-GW09-041A Layer 2 - Yellow mastic JB01 00 GW09 JB-01-00-F-GW09-041A Layer 3 - Brown 9x9 floor tile JB01 00 GW09 JB-01-00-F-GW09-041A Layer 4 - Black mastic JB01 00 GW08A JB-01-00-F-GW08A-042A Layer 1 - Light white 12x12 floor tile JB01 00 GW08A JB-01-00-F-GW08A-042A Layer 2 - Yellow mastic JB01 00 GW08A JB-01-00-F-GW08A-042A Layer 3 - Brown 9x9 floor tile JB01 00 GW08A JB-01-00-F-GW08A-042A Layer 4 - Black mastic JB01 00 GW04 JB-01-00-F-GW04-043A Layer 1 - Green 12x12 floor tile JB01 00 GW04 JB-01-00-F-GW04-043A Layer 2 - Yellow mastic JB01 00 GW04 JB-01-00-F-GW04-043A Layer 3 - Black mastic JB01 00 GW05A JB-01-00-F-GW05A-044A Layer 1 - Light white 12x12 floor tile JB01 00 GW05A JB-01-00-F-GW05A-044A Layer 2 - Yellow mastic JB01 00 GW05A JB-01-00-F-GW05A-044A Layer 3 - Green 12x12 floor tile JB01 00 GW05A JB-01-00-F-GW05A-044A Layer 4 - Black mastic JB01 01 1E21 JB-01-01-F-1E21-045A Layer 1 - Light white 12x12 floor tile JB01 01 1E21 JB-01-01-F-1E21-045A Layer 2 - Yellow mastic JB01 01 1E21 JB-01-01-F-1E21-045A Layer 3 - Green 9x9 floor tile JB01 01 1E21 JB-01-01-F-1E21-045A Layer 4 - Black mastic JB01 01 1E34 JB-01-01-F-1E34-046A Layer 1 - Brown 9x9 floor tile JB01 01 1E34 JB-01-01-F-1E34-046A Layer 2 - Black mastic JB01 01 1E39A JB-01-01-F-1E39A-047A Tan 12x12 floor tile, black mastic JB01 01 1E39 JB-01-01-M-1E39-048A Black lab countertop

JB01 01 H105 JB-01-01-T-H105-049A 10" horizontal - white wrap, foil backing, white block insulation

JB01 01 H105 JB-01-01-F-H105-050A Green 9x9 floor tile, black mastic JB01 01 1E38 JB-01-01-F-1E38-051A Layer 1 - Light white 12x12 floor tile JB01 01 1E38 JB-01-01-F-1E38-051A Layer 2 - Yellow mastic JB01 01 1E38 JB-01-01-F-1E38-051A Layer 3 - Brown 9x9 floor tile JB01 01 1E38 JB-01-01-F-1E38-051A Layer 4 - Black mastic JB01 01 H102 JB-01-01-F-H102-052A Layer 1 - Green 9x9 floor tile JB01 01 H102 JB-01-01-F-H102-052A Layer 2 - Black mastic

JB01 01 1E33 JB-01-01-F-1E33-053A Dark gray 12x12 floor tile, yellow mastic, black mastic

JB01 01 H103 JB-01-01-F-H103-054A Layer 1 - Dark white 9x9 floor tile JB01 01 H103 JB-01-01-F-H103-054A Layer 2 - Black mastic

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 01 H103 JB-01-01-F-H103-055A Layer 1 - Tan 12x12 floor tile JB01 01 H103 JB-01-01-F-H103-055A Layer 2 - Black mastic JB01 01 1E07 JB-01-01-F-1E07-056A Brown 12x12 floor tile, yellow mastic JB01 01 1E05 JB-01-01-M-1E05-057A White vibration isolator JB01 01 1E17A JB-01-01-F-1E17A-058A Light white 12x12 floor tile, yellow mastic JB01 01 1E02 JB-01-01-F-1E02-059A Brown 12x12 floor tile, yellow mastic, black mastic JB01 01 1E01A JB-01-01-F-1E01A-060A Layer 1 - Brown 12x12 floor tile JB01 01 1E01A JB-01-01-F-1E01A-060A Layer 2 - Yellow mastic JB01 01 1E01A JB-01-01-F-1E01A-060A Layer 3 - Dark white 9x9 floor tile JB01 01 1E01A JB-01-01-F-1E01A-060A Layer 4 - Black mastic JB01 01 H104 JB-01-01-F-H104-061A Layer 1 - White 12x12 floor tile JB01 01 H104 JB-01-01-F-H104-061A Layer 2 - Yellow mastic JB01 01 H104 JB-01-01-F-H104-061A Layer 3 - Light white 12x12 floor tile JB01 01 H104 JB-01-01-F-H104-061A Layer 4 - Black mastic JB01 01 1C121A JB-01-01-F-1C121A-062A Gray 12x12 floor tile, black mastic JB01 01 1C102 JB-01-01-F-1C102-063A Gray 12x12 floor tile, black mastic JB01 01 1C104 JB-01-01-F-1C104-064A Gray 12x12 floor tile

JB01 01 H116 JB-01-01-F-H116-065A White 12x12 floor tile, yellow mastic, light white 12x12 floor tile, yellow mastic, black mastic

JB01 01 H119 JB-01-01-T-H119-066A Layer 1 - 6" elbow black mastic JB01 01 H119 JB-01-01-T-H119-066A Layer 2 - Brown wrap fiberglass insulation JB01 01 H119 JB-01-01-T-H119-067A 6" horizontal - gray TSI insulation JB01 01 H119 JB-01-01-T-H119-068A Layer 1 - 4" elbow - black mastic

JB01 01 H119 JB-01-01-T-H119-068A Layer 2 - Brown wrap fiberglass insulation, foil backing

JB01 01 H119 JB-01-01-T-H119-069A Layer 1 - 4" horizontal - brown wrap, foil backing JB01 01 H119 JB-01-01-T-H119-069A Layer 2 - Gray TSI JB01 01 H119 JB-01-01-F-H119-070A Layer 1 - White 12x12 floor tile JB01 01 H119 JB-01-01-F-H119-070A Layer 2 - Yellow mastic JB01 01 H119 JB-01-01-F-H119-070A Layer 3 - Light brown 12x12 floor tile JB01 01 H119 JB-01-01-F-H119-070A Layer 4 - Black mastic JB01 01 1W01 JB-01-01-F-1W01-071A Layer 1 - Light white 12x12 floor tile JB01 01 1W01 JB-01-01-F-1W01-071A Layer 2 - Black mastic JB01 01 1W05 JB-01-01-F-1W05-072A Layer 1 - Brown 12x12 floor tile JB01 01 1W05 JB-01-01-F-1W05-072A Layer 2 - Yellow mastic JB01 01 1W05 JB-01-01-F-1W05-072A Layer 3 - Black mastic JB01 01 1W26 JB-01-01-F-1W26-073A Layer 1 - Light white 12x12 floor tile JB01 01 1W26 JB-01-01-F-1W26-073A Layer 2 - Yellow mastic JB01 01 1W26 JB-01-01-F-1W26-073A Layer 3 - Gray 9x9 floor tile JB01 01 1W26 JB-01-01-F-1W26-073A Layer 4 - Black mastic JB01 01 1W23 JB-01-01-F-1W23-074A Layer 1 - Adhesive, gray 9x9 floor tile JB01 01 1W23 JB-01-01-F-1W23-074A Layer 2 - Black mastic JB01 01 H117 JB-01-01-F-H117-075A Layer 1 - White 12x12 floor tile JB01 01 H117 JB-01-01-F-H117-075A Layer 2 - Yellow mastic JB01 01 H117 JB-01-01-F-H117-075A Layer 3 - Brown 9x9 floor tile, black mastic JB01 01 H117 JB-01-01-F-H117-075A Layer 4 - Black mastic

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 02 2E04 JB-01-02-F-2E04-076A Brown 9x9 floor tile, black mastic JB01 02 2E04 JB-01-02-F-2E04-077A Layer 1 - Dark brown 9x9 floor tile JB01 02 2E04 JB-01-02-F-2E04-077A Layer 2 - Black mastic JB01 02 2E04 JB-01-02-M-2E04-078A White vibration isolator JB01 02 2E04 JB-01-02-T-2E04-079A 6" elbow - white wrap, white block insulation

JB01 02 2E04 JB-01-02-T-2E04-080A 6" horizontal - white wrap, foil backing, yellow fiberglass insulation

JB01 02 2E04 JB-01-02-T-2E04-081A 2" elbow - white wrap, white block insulation JB01 02 2E04 JB-01-02-T-2E04-082A 2" horizontal - white wrap, white block insulation JB01 02 H201 JB-01-02-F-H201-083A Layer 1 - Gray linoleum JB01 02 H201 JB-01-02-F-H201-083A Layer 2 - Yellow mastic JB01 02 2E07A JB-01-02-F-2E07A-084A Layer 1 - White 12x12 floor tile JB01 02 2E07A JB-01-02-F-2E07A-084A Layer 2 - Black mastic JB01 02 2E15 JB-01-02-F-2E15-085A Layer 1 - Gray linoleum JB01 02 2E15 JB-01-02-F-2E15-085A Layer 2 - Black mastic JB01 02 2E19 JB-01-02-F-2E19-086A Layer 1 - Light white 12x12 floor tile JB01 02 2E19 JB-01-02-F-2E19-086A Layer 2 - Yellow mastic JB01 02 2E19 JB-01-02-F-2E19-086A Layer 3 - Black mastic JB01 02 H203 JB-01-02-F-H203-087A Layer 1 - Gray linoleum JB01 02 H203 JB-01-02-F-H203-087A Layer 2 - Yellow mastic JB01 02 H203 JB-01-02-F-H203-087A Layer 3 - Black mastic JB01 02 2W13 JB-01-02-F-2W13-088A Layer 1 - White 12x12 floor tile JB01 02 2W13 JB-01-02-F-2W13-088A Layer 2 - Yellow mastic JB01 02 2W13 JB-01-02-F-2W13-088A Layer 3 - Black mastic JB01 02 2W06 JB-01-02-F-2W06-089A Layer 1 - Brown linoleum JB01 02 2W06 JB-01-02-F-2W06-089A Layer 2 - Black mastic JB01 02 2W22C JB-01-02-F-2W22C-090A Layer 1 - Brown linoleum JB01 02 2W22C JB-01-02-F-2W22C-090A Layer 2 - Black mastic JB01 02 H208 JB-01-02-F-H208-091A Layer 1 - Light white 12x12 floor tile JB01 02 H208 JB-01-02-F-H208-091A Layer 2 - Black mastic JB01 02 2W25 JB-01-02-T-2W25-092A White wrap, white tape, yellow fiberglass insulation JB01 02 H208 JB-01-02-F-H208-093A Light white 12x12 floor tile, black mastic JB01 02 H210 JB-01-02-F-H210-094A Light white 12x12 floor tile, yellow mastic JB01 02 H207 JB-01-02-F-H207-095A Layer 1 - Blue 12x12 floor tile JB01 02 H207 JB-01-02-F-H207-095A Layer 2 - Black mastic JB01 02 2C20 JB-01-02-F-2C20-096A Layer 1 - Dark white 12x12 floor tile JB01 02 2C20 JB-01-02-F-2C20-096A Layer 2 - Yellow mastic and black mastic JB01 02 2C19 JB-01-02-M-2C19-097A Gray transite vent hood JB01 02 2C19 JB-01-02-M-2C19-098A Black lab table tops JB01 02 2C15 JB-01-02-F-2C15-099A Layer 1 - Brown 12x12 floor tile JB01 02 2C15 JB-01-02-F-2C15-099A Layer 2 - Black mastic JB01 02 2C29 JB-01-02-F-2C29-100A Level 1 - Gray 12x12 floor tile JB01 02 2C29 JB-01-02-F-2C29-100A Level 2 - Carpet glue JB01 02 2C29 JB-01-02-F-2C29-100A Level 3 - Black mastic JB01 02 2C22 JB-01-02-F-2C22-101A Layer 1 - Green 9x9 floor tile JB01 2 2C22 JB-01-02-F-2C22-101A Layer 2 - Carpet glue and black mastic

2008 THREE-YEAR ASBESTOS REINSPECTION

SUMMARY OF BULK SAMPLES TAKEN TO DATE

Building Floor Room Sample ID Material Description

Red = Asbestos-Containing Material (ACM) Blue = Non ACM Purple = Abated ACM

JB01 2 2C24 JB-01-02-F-2C24-102A Layer 1 - Dark white 12x12 floor tile JB01 02…