G-000
C O
V E
R
S
H E
E T
FINAL
FEDERAL MINISTRY OF HEALTH
NATIONAL BLOOD TRANSFUSION SERVICE
ADDIS ABABA ,ETHIOPIA
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
FINAL DESIGN
VOLUME 2
21 SEPTEMBER 2015
Z:\Abeselom@BET\ABESELOM TO SARA G_\3d perspective.jpg
G-001
D R
A W
I N
G
I N
D E
X
FINAL
NBTS MAIN BUILDING
GENERAL
G-000 COVER SHEET
G-001 DRAWING INDEX
G-002 GENERAL NOTES AND ABBREVIATIONS
G-003 DOCUMENT NUMBERING AND DRAWING SYMBOLS
G-101 PLANS_LIFE SAFETY _BASEMENT
G-102 PLANS_LIFE SAFETY_GROUND
G-103 PLANS_LIFE SAFETY_FIRST
G-104 PLANS_LIFE SAFETY_SECOND
G-105 PLANS_LIFE SAFETY_THIRD
CIVIL
C-000 CIVIL GENERAL NOTES AND SYMBOLS
C-100 CIVIL SITE SURVEY
C-101 PLAN_EXISTING SITE UTILITY AND PROPOSED SEWER EXTENSION
C-102 PLAN_SITE DEMOLISHING
C-103 PLAN_UTILITY RELOCATION & RECONSTRUCTION
C-104 SITE PLAN WITH TITLE DEED BOUNDARY
C-111 SITE PLAN
C-112 LOCATION PLAN
C-113 PLAN_SITE GRADING AND DRAINAGE
C-114 PLAN_SITE UTILITIES
C-115 ENLARGED PLAN_SITE UTILITY
C-116 PLAN_BASEMENT WALL UTILITY INLET AND OUTLET LOCATIONS
C-117 ELEVATION_BASEMENT WALL UTILITY INLET AND OUTLET LOCATIONS
C-118 PLAN_STAGING, PHASING & EROSION CONTROL
C-501 SECTION_SITE UTILITY
C-501' SECTION_UTILITY
C-502 DETAIL_ DRAINAGE DITCHES AND COVERS
C-505 DETAIL_ GREEN AREAS
C-505' DETAIL_GREEN AREA
C-506 DETAIL_ STAIRS AND RETAINING WALL
C-507 DETAIL_ PAVEMENT
C-508 WEST SIDE FENCE
C-509 SOUTH SIDE FENCE
ARCHITECTURAL
A-000 GENERAL NOTES AND SYMBOLS
A-101 FLOOR PLAN_BASEMENT
A-102 FLOOR PLAN_GROUND
A-103 FLOOR PLAN_FIRST
A-104 FLOOR PLAN_SECOND
A-105 FLOOR PLAN_THIRD
A-106 FLOOR PLAN_ROOF ACCESS
A-107 ROOF PLAN
A-111 CEILING PLAN_BASEMENT
A-112 CEILING PLAN_GROUND
A-113 CEILING PLAN_FIRST
A-114 CEILING PLAN_SECOND
A-115 CEILING PLAN_THIRD
A-116 CEILING PLAN _ROOF ACCESS
A-121 FURNITURE AND EQUIPMENT PLAN_BASEMENT
A-122 FURNITURE AND EQUIPMENT PLAN_GROUND
A-123 FURNITURE AND EQUIPMENT PLAN_FIRST
A-124 FURNITURE AND EQUIPMENT PLAN_SECOND
A-125 FURNITURE AND EQUIPMENT PLAN_THIRD
A-126 FURNITURE AND EQUIPMENT PLAN_ON ROOF SLAB
A-126' ENLARGED FLOOR PLAN _EQUIPMENT ROOM
A-126" EQUIPMENT ROOM DETAIL_SECTIONAL ELEVATIONS
A-131 FINISH AND SIGNAGE PLAN BASEMENT
A-132 FINISH AND SIGNAGE PLAN GROUNF\D
A-133 FINISH AND SIGNAGE PLAN FIRST
A-134 FINISH AND SIGNAGE PLAN SECOND
A-135 FINISH AND SIGNAGE PLAN THIRD
A-136 FINISH AND SIGNAGE PLAN ROOF ACCESS
A-137 FINISH AND SIGNAGE PLAN ROOF
A-201 EXTERIOR ELEVATIONS -EAST AND WEST
A-202 EXTERIOR ELEVATIONS - NORTH AND SOUTH
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-311 WALL SECTIONS AND WALL TYPES
A-312 WALL SECTIONS AND WALL TYPES
A-401 ENLARGED KITCHEN PLAN AND INTERIOR ELEVATIONS
A-402 ENLARGED KITCHEN PLAN AND INTERIOR ELEVATIONS
A-403 ENLARGED TOILET PLAN AND INTERIOR ELEVATIONS
A-404 ENLARGED TOILET PLAN AND INTERIOR ELEVATIONS
A-405 ENLARGED TOILET PLAN AND INTERIOR ELEVATIONS
A-406 ENLARGED CHANGING PLAN AND INTERIOR ELEVATIONS
A-407 ENLARGED CHANGING PLAN AND INTERIOR ELEVATIONS
A-408 ENLARGED CHANGING PLAN AND INTERIOR ELEVATIONS
A-409 ENLARGED LAUNDRY PLAN AND INTERIOR ELEVATIONS
A-410 ENLARGED LABORATORY PLAN INTERIOR ELEVATIONS
A-411 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-412 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-413 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-414 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
NBTS MAIN BUILDING
GENERAL
G-000 COVER SHEET
G-001 DRAWING INDEX
G-002 GENERAL NOTES AND ABBREVIATIONS
G-003 DOCUMENT NUMBERING AND DRAWING SYMBOLS
MECHANICAL
M-000 MECHANICAL GENERAL NOTES AND SYMBOLS
M-101 MECHANICAL PLAN_BASEMENT
M-102 MECHANICAL PLAN_GROUND
M-103 MECHANICAL PLAN_FIRST
M-104 MECHANICAL PLAN_SECOND
M-105 MECHANICAL PLAN_THIRD
M-106 MECHANICAL PLAN_ROOF ACCESS
M-107 MECHANICAL ROOF PLAN
M-108 VRF AIR CONDITIONING SYSTEM SCHEMATIC
M-109 MECHANICAL EQUIPMENT SCHEDULE
M-110 MECHANICAL DETAIL-1
M-111 MECHANICAL DETAIL-2
ELECTRICAL
E-000 ELECTRICAL GENERAL NOTES AND SYMBOLS
E-101 LIGHTING FLOOR PLAN_BASEMENT
E-102 LIGHTING FLOOR PLAN_GROUND
E-103 LIGHTING FLOOR PLAN_FIRST
E-104 LIGHTING FLOOR PLAN_SECOND
E-105 LIGHTING FLOOR PLAN_THIRD
E-106 LIGHTING FLOOR PLAN_ROOF
E-111 SOCKET & POWER OUTLET FLOOR PLAN_BASEMENT
E-112 SOCKET & POWER OUTLET FLOOR PLAN_GROUND
E-113 SOCKET & POWER OUTLET FLOOR PLAN_FIRST
E-114 SOCKET & POWER OUTLET FLOOR PLAN_SECOND
E-115 SOCKET & POWER OUTLET FLOOR PLAN_THIRD
E-116 SOCKET & POWER OUTLET FLOOR PLAN_ROOF
E-121 SOCKET & POWER OUTLET FLOOR PLAN_GROUND (CLEAN POWER -UPS)
E-122 SOCKET & POWER OUTLET FLOOR PLAN_FIRST (CLEAN POWER -UPS)
E-123 SOCKET & POWER OUTLET FLOOR PLAN_SECOND (CLEAN POWER -UPS)
E-124 SOCKET & POWER OUTLET FLOOR PLAN_THIRD (CLEAN POWER -UPS)
E-131 TELE/DATA SYSTEM FLOOR PLAN BASEMENT
E-132 TELE/DATA SYSTEM FLOOR PLAN_GROUND
E-133 TELE/DATA SYSTEM FLOOR PLAN_FIRST
E-134 TELE/DATA SYSTEM FLOOR PLAN_SECOND
E-135 TELE/DATA SYSTEM FLOOR PLAN_THIRD
E-141 FIRE ALARM & TV SYSTEM FLOOR PLAN_BASEMENT
E-142 FIRE ALARM & TV SYSTEM FLOOR PLAN_GROUND
E-143 FIRE ALARM & TV SYSTEM FLOOR PLAN_FIRST
E-144 FIRE ALARM & TV SYSTEM FLOOR PLAN_SECOND
E-145 FIRE ALARM & TV SYSTEM FLOOR PLAN_THIRD
E-151 PUBLIC ADDRESS SYSTEM FLOOR PLAN_GROUND
E-152 PUBLIC ADDRESS SYSTEM FLOOR PLAN_THIRD
E-161 LIGHTNING PROTECTION SYSTEM_ROOF LEVEL
E-501 DETAILS
E-502 DETAILS
E-503 DETAILS
E-504 DETAILS
E-601 POWER PANEL SCHEDULE
E-602 POWER PANEL SCHEDULE
E-603 LIGHT FIXTURES SCHEDULE AND RISER DIAGRAM
E-604 PLAN_SITE COMPOUND LIGHTING
E-605 DETAIL_ UTILITY MANHOLES AND TRENCHES
PLUMBING (SANITARY)
P-000 PLUMBING GENERAL NOTES AND SYMBOLS
P-101 PLUMBING BASEMENT FLOOR PLAN
P-102 PLUMBING GROUND FLOOR PLAN
P-102' ENLARGED PLUMBING GROUND FLOOR PLAN
P-103 PLUMBING FIRST FLOOR PLAN
P-103' ENLARGED PLUMBING FIRST FLOOR PLAN
P-104 PLUMBING SECOND FLOOR PLAN
P-104' ENLARGED PLUMBING SECOND FLOOR PLAN
P-105 PLUMBING THIRD FLOOR PLAN
P-105' ENLARGED PLUMBING THIRD FLOOR PLAN
P-106 PLUMBING ATTIC FLOOR PLAN
P-201 RISER DIAGRAMS PLUMBING
P-202 RISER DIAGRAMS PLUMBING
P-203 RISER DIAGRAMS PLUMBING
P-204 RISER DIAGRAMS PLUMBING
P-205 RISER DIAGRAMS PLUMBING
P-206 RISER DIAGRAMS PLUMBING
P-207 RISER DIAGRAMS PLUMBING
P-208 RISER DIAGRAMS PLUMBING
P-301 INTERNAL PLUMBING DETAIL
P-302 PLUMBING BASEMENT LAB WASTE TREATMENT TANKS
P-303 DETAILS - SEWER MANHOLE TRENCH AND SEWER CROSS
OVER SUBSURFACE DRAINAGE LINE
P-304 PLAN_SITE SUBSURFACE DRAINAGE SYSTEM
P-305 SECTION_SITE SUBSURFACE DRAINAGE SYSTEM
P-306 DETAIL_ UTILITY MANHOLES AND TRENCHES
A-415 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-416 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-417 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-418 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-419 ENLARGED LABORATORY PLAN AND INTERIOR ELEVATIONS
A-420 ENLARGED EMERGENCY SHOWER PLAN AND INTERIOR ELEVATIONS
A-501 EXTERIOR WALL SECTIONS
A-502 EXTERIOR WALL SECTIONS
A-503 EXTERIOR DETAILS
A-504 EXTERIOR DETAILS
A-505 EXTERIOR DETAILS
A-511 INTERIOR DETAILS
A-512 INTERIOR DETAILS
A-513 INTERIOR DETAILS
A-514 INTERIOR DETAILS
A-515 INTERIOR DETAILS
A-516 INTERIOR DETAILS
A-601 ROOM FINISH SCHEDULE
A-602 ROOM FINISH SCHEDULE
A-611 DOOR SCHEDULE
A-612 DOOR SCHEDULE
A-621 WINDOW SCHEDULE
A-622 WINDOW SCHEDULE
A-631 SIGNAGE SCHEDULE
A-632 SIGNAGE SCHEDULE
A-641 TYPICAL DOOR HEAD DETAILS
A-642 TYPICAL DOOR JAMB DETAILS
A-643 TYPICAL DOOR SILL DETAILS
A-644 TYPICAL WINDOW SILL DETAILS
A-801 VERTICAL CIRCULATION - STAIR 1
A-802 VERTICAL CIRCULATION - STAIR 1
A-803 VERTICAL CIRCULATION - STAIR 2
A-804 VERTICAL CIRCULATION - STAIR 2
A-805 VERTICAL CIRCULATION - ELEVATOR
A-806 VERTICAL CIRCULATION - STEEL STAIR
STRUCTURAL
S-000 STRUCTURAL GENERAL NOTES AND SYMBOLS
S-101 FORMWORK PLAN_BASEPLATE
S-102 FORMWORK PLAN BASEMENT CEILING
S-103 FORMWORK PLAN TYPICAL CEILING
S-111 REINFORCEMENT PLAN - BASE PLATE 1/2
S-112 REINFORCEMENT PLAN - BASE PLATE 2/2
S-113 REINFORCEMENT PLAN BASEMENT CEILING
S-114 REINFORCEMENT PLAN TYPICAL CEILING
S-121 GENERAL PLAN - ROOF BEAM LAYOUT AND DETAIL
S-122 GENERAL PLAN - ROOF TRUSS LAYOUT
S-301 SECTION - SHEAR WALLS (1/2)
S-302 SECTION - SHEAR WALLS (2/2)
S-311 SECTION_GRAVITY AND RETAINING WALLS
S-501 REINFORCEMENT BASEMENT CEILING BEAM (1/3)
S-502 REINFORCEMENT BASEMENT CEILING BEAM (2/3)
S-503 REINFORCEMENT BASEMENT CEILING BEAM (3/3)
S-504 REINFORCEMENT TYPICAL CEILING BEAM (1/3)
S-505 REINFORCEMENT TYPICAL CEILING BEAM (2/3)
S-506 REINFORCEMENT TYPICAL CEILING BEAM (3/3)
S-507 REINFORCEMENT ROOF BEAM (1/3)
S-508 REINFORCEMENT ROOF BEAM (2/3)
S-509 REINFORCEMENT ROOF BEAM (3/3)
S-510 DETAIL - ROOF PARAPET WALLS
S-511 DETAIL - ROOF TRUSS (1/3)
S-512 DETAIL - ROOF TRUSS (2/3)
S-513 DETAIL_ROOF TRUSS (3/3)
S-521 DETAIL_COLUMNS
S-601 SCHEDULE_COLUMNS
S-602 SCHEDULE_ BASE PLATE
S-603 SCHEDULE_BASEMENT CEILING
S-604 SCHEDULE_TYPICAL CEILING
S-605 SCHEDULE - BEAMS
S-606 SCHEDULE - GRAVITY & RETAINING WALLS
S-607 SCHEDULE- STRUCTURAL STEEL - TRUSS AND ROOF SLAB
S-801 REINFORCEMENT _STAIR
S-802 REINFORCEMENT_RAMP
S-901 SITE LAYOUT
S-902 FENCE FOUNDATION, STEP, DITCH, DITCH COVER AND
TRANSFORMER PAD DETAIL
S-903 SITE RETAINING WALL AND EXHAUST DUCT
S-904 REINFORCEMENT GUARD HOUSE (1/2)
S-905 TRUSS DETAIL AND SCHEDULE GUARD HOUSE (2/2)
S-906 FIRE ESCAPE STAIR (1/3)
S-907 FIRE ESCAPE STAIR (2/3)
S-908 FIRE ESCAPE STAIR (3/3)
S-909 REINFORCEMENT AND TRUSS INCINERATOR
S-910 PUMP SUMP, PAD AND MANHOLE AND DITCH COVER DETAIL
FIRE PROTECTION
F-000 FIRE NOTES
F-101 FIRE WATER SUPPLY BASEMENT FLOOR PLAN
F-102 FIRE WATER SUPPLY GROUND FLOOR PLAN
F-103 FIRE WATER SUPPLY FIRST FLOOR PLAN
F-104 FIRE WATER SUPPLY SECOND FLOOR PLAN
F-105 FIRE WATER SUPPLY THIRD FLOOR PLAN
F-106 FIRE WATER SUPPLY ATTIC FLOOR
F-201 FIRE WATER SUPPLY RISER DIAGRAM
NBTS - GUARD HOUSE
ARCHITECTURAL
A-950 FLOOR PLAN,SECTIONS AND ELEVATIONS
ELECTRICAL
E-950 PLAN LIGHTING ,SOCKET AND TELEPHONE
NBTS - INCINERATOR PAD AND SHADE
ARCHITECTURAL
A-960 FLOOR PLAN,SECTIONS AND ELEVATIONS
ELECTRICAL
E-960 LIGHTING _FLOOR PLAN
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
VOLUME 1 DRAWINGS VOLUME 2 DRAWINGS
GENERAL ABBREVIATIONS
& AND
< ANGLE
@ AT
Ø DIAMETER
% PERCENT
1PH SINGLE PHASE
3PH THREE PHASE
AB ANCHOR BOLT
ABAN ABANDONED
ABV ABOVE
ACC ACCESSIBLE
ACRLC ACRYLIC
ADDL ADDITIONAL
ADJ ADJUSTABLE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARD INSTITUTE
APPRX APPROXIMATE; APPROXIMATELY
A ARCHITECTURAL (DRAWINGS)
AFF ABOVE FINISH FLOOR LEVEL
AMT AMENDMENT
BD BOARD
BT/W BETWEEN
BLCK BLOCK
BLKG BLOCKING
BM BENCHMARK
BO BOTTOM OF
BOT BOTTOM
BRK BRICK
CAB CABINET
CBL CABLE
CI CAST IRON
C CIVIL(DRAWINGS)
C/C CENTER TO CENTER
CHEM CHEMICAL
CHWB COMPACT HAND WASH BASIN
CHS CIRCULAR HOLLOW STEEL SECTION
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR(ANCE)
COL COLUMN
CM CENTIMETER
CO CLEAN OUT
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CT CERAMIC TILE
CTR CENTER
CW COLD WATER; CURTAIN WALL
D DOOR
DBL DOUBLE
DR DOOR
DEG DEGREE
DEMO DEMOLISH
DET,DTL DETAIL
DF DRINKING FOUNTAIN
DG DOOR GRILL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSARY
DISTRIB DISTRIBUTION
DMH DROP MANHOLE
DN DOWN
DP DOWN PIPE
DS DOWNSPOUT
DWG DRAWING
E EAST, EASTING, EYE,ELECTRICAL(DRAWINGS)
EA EACH
EEPCO ETHIOPIA ELECTRIC POWER CORPORATION
EF EXHAUST FAN
EL ELECTRICAL
ELEV, EL ELEVATION
EJ EXPANSION JOINT
EMLSN EMULSION
EMRG EMERGENCY
ENML ENAMEL
EP ELECTRICAL PANEL
EPT EXTERIOR PAINT
EPXY EPOXY
EQ EQUAL
EQP EQUIPMENT
ETC ET CETERA
EW EACH WAY
EWT ELEVATED WATER TANK
EXH EXHAUST
EXP EXPOSED; EXPANDED; EXPANSION
EXST EXISTING
EXT EXTERIOR; EXTRUDED; EXTENSION
ROOM NAME ABBREVIATIONS
ACC ACCESSIBLE
ADMIN ADMINISTRATION
ARCH ARCHIVE
CASH CASHIER
CEN CENTRAL
CHG CHANGING
CLD COLD
CORD COORDINATOR
CORR CORRIDOR
D DONOR
EL ELECTRICAL
EM EMERGENCY
EMRG EMERGENCY
ENG ENGINEERING
EXAM EXAMINATION
F FEMALE
GEN GENERAL
IT INFORMATION TECHNOLOGY
IDT INFECTIOUS DISEASE TESTING
JAN JANITOR
LAB LABORATORY
M MALE
NUCL NUCLEIC
OFF OFFICE
OFFR OFFICER
PROC PROCUREMENT
QUAR QUARANTINE
RM ROOM
RECEPT RECEPTION
SER SERVICE
STORE STORAGE
STRUCTURAL STEEL SHAPES
CHS DDxTT DIAMETER x THICKNESS (IN MM) FP WWxLLxTT WIDTH x LENGTH X THICKNESS (IN MM) RHS WWxHHxTT WIDTH x HEIGHT X THICKNESS (IN MM) SHS WWxTT WIDTH x THICKNESS (IN MM)
F/ FROM
FAV FOOT ACTUATED VALVE
FD FLOOR DRAIN
FE (WALL MOUNTED) FIRE EXTINGUISHER
FF FINISHED FLOOR
FFE FINISH FLOOR ELEVATION
FFL FINISH FLOOR LEVEL
FG FINISHED GRADE
FHR FIRE HOSE REEL BOX
FIN FINISH(ED)
FIXT FIXTURE
FLR FLOOR
FMRP FORMED METAL ROOF PANEL
FMOH FEDERAL MINISTRY OF HEALTH
FNC FENCE
FO FACE OF
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STEEL
FP FLAT PLATE; FLAT BAR
FTG FOOTING
FW FACE WASH
GA GAUGE; GAGE
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
GEN GENERAL
GL GRID LINE; GLASS
GWT GROUND MOUNTED WATER TANK
H HIGH, HEIGHT
HCB HOLLOW CONCRETE BLOCK
HC HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE PIPE
HDWR HARDWARE
HL HIGHER LEVEL
HOR HORIZONTAL
HPL HIGH PRESSURE LAMINATE
HWB HAND WASH BASIN
HW HOT WATER
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IDEN IDENTIFY; IDENTITY; IDENTIFICATION
IE INVERT ELEVATION
INCIN INCINERATOR
INCL INCLUDE; INCLUDES; INCLUDING
INT INTERIOR
JT JOINT; JANITOR TROUGH
KWHM KILOWATT-HOUR METER
KS KITCHEN SINK
L LENGTH
LAV LAVATORY
LL LOWER WATER
LM LINEAR METERS
LS LABORATORY SINK
LT LITTER
LTG LIGHTING
LVL LEVEL
M METER
MAT MATERIAL
MACH MACHINE
MAX MAXIMUM
MDB MAIN DISTRIBUTION BOARD
MDF MEDIUM DENSITY FIBERBOARD
MFR MANUFACTURER
MG MIRROR GLASS
MH, MHS MANHOLE, MANHOLES
MIN MINIMUM
MM MILLIMETER
MO MASONRY OPENING
MONO MONOLITHIC
MTD MOUNTED
MTL METAL
N NORTH; NOTHING
NBTS NATIONAL BLOOD TRANSFUSION SERVICE
NGL NATURAL GROUND LEVEL
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OH OVERHEAD
OTS OPEN TO STRUCTURE
P PLUMBING (DRAWINGS)
PART PARTITION; PARTIAL
PAV PAVING
PERC PERCOLATION
PERF PERFORATED
PERP PERPENDICULAR
PLAS PLASTER
PLC PT PLACENTA PIT
PLSTC PLASTIC
PLT PLATE
PLWD PLYWOOD
PNL PANEL
PT PRESSURE TREATED; PAINT; PAINTED
PV PHOTOVOLTAIC
PVC POLYVINYL CHLORIDE
R RADIUS; RISER
RC REINFORCED CONCRETE
RD ROOF DRAIN
RECEP RECEPTACLE
REF REFER TO; REFERENCE
REIN REINFORCEMENT
REQ REQUIRED
REV REVISION; REVISED
RF ROOF
RHS RECTANGULAR HOLLOW STEEL SECTION
RM ROOM
RO ROUGH OPENING
S SEWER, SOUTH, STRUCTURAL(DRAWINGS)
SAN SANITARY
SC SOLID CORE
SCHED SCHEDULE
SDB STANDARD DETAIL BOOK
SECT SECTION
SH SHOWER
SHS SQUARE HOLLOW STEEL SECTION
SHT SHEET
SKTG SKIRTING
SLR SEALER
SM SQUARE METER(S)
SPEC SPECIFICATION
SPH SOAP HOLDER
SQ SQUARE
SS SANITARY SEWER
SSMH SUBSURFACE MANHOLE
SSTL STAINLESS STEEL
SSW STAINLESS STEEL HAND WASH BASIN
SS WD SEMI SOLID WOOD
ST STIRRUP
STD STANDARD
STL STEEL
STRUCT STRUCTURAL (DRAWINGS)
SUSP SUSPENDED
SYM SYMETRICAL
SYST SYSTEM
SYNTH SYNTHETIC
T TREAD
TB TOWEL BAR
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERED
THK THICK
THRU THROUGH
TL TILE
TLT TOILET
TO TOP OF
TOS TOP OF SLAB OR STEEL
TPVLV TEMPERATURE AND PRESSURE RELIEF VALVE
TRT TREATED
TTD TOILET TISSUE DISPENSER
TU TUB
TYP TYPICAL
UG UNDERGROUND
UNF UNFINISHED
UNO UNLESS NOTED OTHERWISE
UPVC UNPLASTICIZED POLYVINYL CHLORIDE
UTIL UTILITY
VAR VARIES
VCT VINYL COMPOSITION TILE
VENT VENTILATING
VER VERIFY
VERT VERTICAL
VL VINYL
VTR VENT THROUGH ROOF
W WINDOW; WIDE; WIDTH; WEST; WASHER; WATER; WAY
WAS WASH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDL WATER DISTRIBUTION LINE
WH WATER HEATER
WL WALL
WM WATER METER
WP WATERPROOF
WR WATER RESISTANT
WS WATER SUPPLY
WT WEIGHT
WW WASTEWATER
WWL WASTEWATER LINE
Z Z COORDINATE
G-002
G
EN
ER
A
L N
O
TE
S
A B
B R
EV
IA
TI
O
N S
FINAL
GENERAL NOTES
& ABBREVIATIONS
w w w .te tra te ch .c om O ne G ra nt
S tre et Fr am in gh am
, M A
8.
3.
GENERAL NOTES
1. REFER TO STANDARD DETAIL BOOK FOR TYPICAL DETAILS. ALL
TYPICAL DETAILS ARE NOT CALLED OUT INDIVIDUALLY; APPLY
TYPICAL DETAILS IN ALL APPLICABLE CASES.
2. ALL WORK SHALL COMPLY WITH 2009 INTERNATIONAL BUILDING
CODE; 2009 NATIONAL FIRE PROTECTION ASSOCIATION 101 LIFE
SAFETY CODE; AND LOCAL BUILDING CODES.
3. VERIFY EXISTING SITE LAYOUT, DIMENSIONS, AND SITE CONDITIONS,
INCLUDING LOCATION OF ALL BELOW-GRADE UTILITIES, IN THE FIELD
PRIOR TO COMMENCEMENT OF DEMOLITION/RENOVATION WORK.
REPORT ANY DISCREPANCIES TO THE COR BEFORE PROCEEDING
WITH AFFECTED PORTION OF WORK.
4. REVIEW EXISTING CONDITION OF LANDSCAPE PLANTING PRIOR TO
COMMENCEMENT OF WORK. PROTECT PLANTING FROM DAMAGE
DURING WORK. RESTORE DAMAGED PLANTING AT CLOSE OF WORK.
5. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS
REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. THE
CONTRACTOR SHALL COORDINATE ALL PORTIONS OF WORK AS
DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE COR FOR
RESOLUTION OF ALL DISCREPANCIES PRIOR TO COMMENCEMENT OF
WORK.
6. DIMENSIONS ARE TO STRUCTURAL GRID OR TO FINISH SURFACES,
UNLESS NOTED OTHERWISE. VERIFY IN FIELD AND REPORT ANY
DISCREPANCIES TO THE COR BEFORE PROCEEDING WITH AFFECTED
PORTION OF WORK.
7. ALL EXISTING STRUCTURES, APPURTENANCES, BURIED UTILITY
LINES, AND FINISH ELEMENTS NOT INDICATED TO BE DEMOLISHED
SHALL BE PROTECTED FROM DAMAGE.
8. ALL DEMOLITION WORK SHALL BE NONDESTRUCTIVE AND
PERFORMED NEATLY, DISTURBING ADJACENT ELEMENTS TO THE
MINIMUM EXTENT PRACTICAL. ADJACENT ELEMENTS DAMAGED IN
THE PROCESS SHALL BE PATCHED TO MATCH SUCH THAT THE
PATCH, WHEN COMPLETED, IS NOT NOTICEABLE AS SUCH.
9. FMOH BUILDING TO REMAIN OCCUPIED AND OPERATIONAL
THROUGHOUT THE CONSTRUCTION PERIOD. MAINTAIN OPERABILITY
OF ALL UTILITIES. MAINTAIN OCCUPANT ACCESS TO AND EGRESS
FROM ALL OCCUPIED BUILDINGS THROUGHOUT ENTIRETY OF
CONSTRUCTION PERIOD.
10. CONTRACTOR SHALL DESIGNATE THE "LIMIT OF WORK AREA"
WHEREIN ALL WORK AND ACTIVITIES SHALL BE CONDUCTED.
MATERIAL AND EQUIPMENT STORAGE SHALL BE WITHIN THIS AREA.
THIS AREA SHALL BE KEPT NEAT AND CLEAN AT ALL TIMES.
APPROPRIATE BARRICADES SHALL BE ERECTED TO PREVENT
UNAUTHORIZED PERSONS FROM ENTERING THE WORK AREA OR
FROM CONSTRUCTION WORKERS FROM ENTERING OCCUPIED FMOH
11. PROTECT ADJACENT BUILDINGS FROM DUST, CONSTRUCTION
DEBRIS AND MOISTURE DURING WORK.
12. REPETITIVE FEATURES NOT NOTED ON THE DWGS SHALL BE
PROVIDED AS IF DRAWN IN FULL.
13. CHAMFER EXTERNAL CORNERS ON EXPOSED CIP CONC 20 MM TYP,
UNO.
14. ROOM AND DOOR NUMBERS SHOWN ON DWGS ARE FOR
CONSTRUCTION PURPOSES ONLY.
15. ALL WOOD EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE
OR MASONRY SHALL BE PRESERVATIVE-TREATED WOOD.
16. PRIOR TO COMMENCEMENT OF ANY WORK AT THE SITE, THE
CONTRACTOR SHALL PREPARE PROJECT PHASING AND STAGING
PLAN, WHICH WILL DESCRIBE HOW THE CRITICAL NEEDS OF THE
NBTS PROJECT SHALL BE PRESERVED UNINTERRUPTED DURING THE
CONSTRUCTION PERIOD. THE PROJECT PHASING AND STAGING PLAN
MUST BE APPROVED BY THE SITE ENGINEER AND ENDORSED BY THE
HEALTH CENTER HEAD BEFORE THE CONTRACTOR MAY MOBILIZE
ONTO THE SITE.
17. FOR ELECTRICAL DRAWINGS INDICATE AS KEYED PLAN NOTES, IN
FIXTURE SCHEDULES AND IN GENERAL NOTES APPROPRIATELY:
17.1. EXTERIOR EMERGENCY LIGHTING FIXTURES WITH BATTERY
BACK-UP POWER KITS ARE N.I.C.
17.2. INTERIOR EMERGENCY LIGHTING FIXTURES WITH BATTERY BACK-UP
POWER KITS ARE N.I.C.
17.3. INTERIOR AND EXTERIOR LIGHTING FIXTURES ARE N.I.C. PROVISIONS
FOR FIXTURE MOUNTING AND CONDUITS AND CABLING FOR INTERIOR
AND EXTERIOR LIGHTING FIXTURES ARE TO VERIFIED WITH THE
OWNER PRIOR TO COMMENCEMENT OF WORKS.
17.4. SATELLITE DISH AND ASSOCIATED CABLING AND TV ARE N.I.C.
DOCUMENT NUMBERING SYSTEM
DISCIPLINE SHEET TYPE SEQUENTIAL
X-XXX
A-101
CODE DISCIPLINE
G GENERAL
C CIVIL
A ARCHITECTURAL
S STRUCTURAL
P PLUMBING
E ELECTRICAL
CODE SHEET TYPE DESIGNATOR
0 GENERAL
1 PLANS
2 ELEVATIONS
3 SECTIONS
4 ENLARGED VIEWS
5 DETAILS
6 SCHEDULES AND DIAGRAMS
8 VERTICAL CIRCULATION
9 3D IMAGE
DOCUMENT REFERENCING SYSTEM
CROSS REFERENCING IS DONE IN THE FOLLOWING
MANNER:
PLAN1
SCALE: NTS
SOURCE PLAN REFERENCE:
PLAN / DETAIL1
A-101 SCALE: NTS
DETAIL / ENLARGED PLAN REFERENCE:
REFERENCE DESIGNATION NUMBER
SOURCE SHEET
SECTION REFERENCE:
REFERENCE DESIGNATION NUMBER
SOURCE SHEET
REFERENCE DESIGNATION NUMBER
NOT USED
EXTERIOR ELEVATION REFERENCE:
A- ##
REFERENCE DESIGNATION LETTER
SHEET WHERE ELEVATION IS DRAWN
A-202
REFERENCE
DESIGNATION
NUMBER, TYP
SHT WHERE ELEV IS DRAWN
BAR SCALE
1 REVISION
CL
00 KEY NOTE TAG
A- ##
REFERENCE DESIGNATION NUMBER
SHEET WHERE DETAIL IS DRAWN
INTERIOR ELEVATION REFERENCE:
A-202
REFERENCE
DESIGNATION
NUMBER
SHT WHERE ELEV IS DRAWN
BUILDING SECTION REFERENCE:
REFERENCE DESIGNATION NUMBER
SHEET WHERE SECT IS DRAWN
DETAIL OR PARTIAL SECTION REFERENCE:
REFERENCE DESIGNATION NUMBER
SHEET WHERE DET OR PART SECT IS DRAWN
A- ##
DETAIL CALLOUT:
BREAK LINE
MULTIPLE
ELEVATIONS:
ONE
ELEVATION:
GENERAL SYMBOLS
STANDARD DETAIL BOOK REFERENCING IS DONE IN
THE FOLLOWING MANNER:
AX- ##
REFERENCE DESIGNATION NUMBER
SHEET WHERE DETAIL IS DRAWN
DETAIL CALLOUT:
4 TYP NOTE APPLIES TO
ALL SIMILAR
ELEMENTS ON
SHEET
33 NOTE APPLIES TO
BOUNDED AREA
DIMENSION LINE
CENTERLINE
SPOT ELEVATION
(EXISTING)
PLAN
NORTH
NORTH ARROW
100.00 BM OR SPOT
ELEVATION
(NEW)
RIGHTS IN DATA
1. THE DRAWINGS CONTAINED HEREIN WERE DEVELOPED BY TETRA
TECH, INC., FRAMINGHAM, MASSACHUSETTS, USA UNDER CONTRACT
NO. EDH-I-00-08-0027 ORDER NO. AID-663-TO-11-00001 AND ARE
SUPPLIED IN ACCORDANCE WITH THE FOLLOWING CLAUSE
CONTAINED WITHIN THIS CONTRACT, FEDERAL ACQUISITION
REGULATIONS (FAR) 52.227-14, RIGHTS IN DATA - GENERAL
(DECEMBER 2007).
2. FURTHERMORE, IN ACCORDANCE WITH FAR 52.227-14 (B) (2) (III),
THESE DOCUMENTS HAVE BEEN PRODUCED IN HARD COPY FORMAT
FOR USE BY THE CONSTRUCTION CONTRACTOR. IF THERE ARE ANY
QUESTIONS OR DISCREPANCIES BETWEEN THESE DOCUMENTS AND
COPIES MADE FROM AN ELECTRONIC FILE, THE HARD COPY
DOCUMENTS WILL TAKE PRECEDENCE. TETRA TECH, INC., WILL NOT
BE RESPONSIBLE FOR ANY VERSIONS OF THESE DOCUMENTS
PRINTED FROM THE ELECTRONIC FILES BY OTHERS.
1 2 3 4
5 6 7 8
9 10 11 12
DETAIL NUMBERS ARE BASED ON
LOCATION OF THE DETAIL
DRAWING ON THE DETAIL SHEET
AND MAY NOT BE SEQUENTIAL.
DET 10
DET 11DET 9
100.00 ELEVATION
U WC
2.6 SM
ROOM NAME,
NUMBER AND
SQUARE METER
TAG
LINETYPE SYMBOLS
LIMITS OF CONST
SITE WATER UG DISTRIB PIPING - EXSTW
SITE POWER UG LINE - EXSTUE
STRUCT GL IDEN
GENERAL - EXISTING
GENERAL - DEMO
GENERAL - NEW
PROPERTY LINE
xxxx FENCE - EXISTING xxxx FENCE - DEMO OR NEW
SITE WATER UG DISTRIB PIPING - DEMO/NEWW
SITE SAN SEWER UG PIPING - DEMO/NEWSS
SITE POWER UG LINE - DEMO/NEWUE
SITE TELECOMM UG LINE - EXSTUT
SITE TELECOMM UG LINE - DEMO/NEWUT
SITE POWER OVHD LINE - EXSTOE
SITE POWER OVHD LINE - DEMO/NEWOE
SITE TELECOMM OVHD LINE - EXSTOT
SITE TELECOMM OVHD LINE - DEMO/NEWOT
G-003
D O
C U
M
EN
T N
U M
B
ER
IN
G
A N
D D
R A
W
IN
G S
YM
B
O
LS
FINAL
DOCUMENT NUMBERING
AND DRAWING SYMBOLS
A-xx
A- ## w w w .te tra te ch .c om O ne G ra nt
S tre et Fr am in gh am
, M A
8.
3.
FLOOR WALL CEILING
FINISHING NOTE TAG
33333
CW1
WINDOW AND
CURTAIN WALL
TYPE TAG
W1
WL1 WALL TYPE TAG
DOOR TAG100
ROOM SIGNAGE100
A-1 EQUIPMENT CODE
FROM ABOVE
GENERAL NOTES
1. ALL DIMENSIONS ARE IN MILLIMETER
2. MECHANICAL SERVICES SHALL NOT PASS THROUGH STRUCTURAL BEAMS OR
ANY OTHER STRUCTURAL ELEMENTS UNLESS A PRIOR WRITTEN APPROVAL
HAS BEEN TAKEN FROM THE USID.
3. CONTRACTOR SHALL EXECUTE ALL WORKS AS PER APPROVED SHOP DRAWINGS.
4. CONTRACTOR SHALL PROVIDE VOLUME DAMPERS WHERE SHOWN ON THE DRAWING
5. ALL DUCTWORK CONSTRUCTION AND INSTALLATION SHALL BE IN COMPLIANCE WITH
SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION("SMACNA)
MEDIUM PRESSURE AS PER ETHIOPIAN BUILDING CODE STANDARD FOR VENTILATION AND
AIR CONDITIONING SERVICES (EBCS-11,1995)
9. DUCT SHALL BE LEAK TESTED AS PER ETHIOPIAN BUILDING COD STANDARD FOR
VENTILATION AND AIR CONDITIONING SERVICES (EBCS-11,1995)
6. CONTRACTOR SHALL CALCULATE THE STATIC PRESSURE REQUIREMENT OF THE
FANS TO THE USAID FOR APPROVAL, BASED ON THE TYPE OF THE FINAL
MECHANICAL EQUIPMENT PARTS TO BE INSTALLED AND ACTUAL DUCT LAYOUT.
10. CONTRACTOR IS RESPONSIBLE FOR TESTING ADJUSTING AND BALANCING OF
THE HEATING VENTILATION AND AIR CONDITIONING(HVAC) SYSTEM.
8 THERMOSTAT SHALL BE MOUNTED MIN. 1500mm ABOVE FLOOR FINISH LEVEL FOR AIR
CONDITIONING SYSTEMS
7. MECHANICAL SUB CONTRACTOR SHALL PROVIDE SLEEVES ON ALL DUCTS AND PIPES
PENETRATING WALLS, BEAMS & SLABS FOR ALL WALL MOUNTED GRILLES, LOUVERS,
EQUIPMENT AND WHERE REQUIRED
12. AIR TERMINALS LOCATIONS SHALL BE COORDINATED WITH RESPECT TO OTHER
SERVICES SUCH AS ELECTRICAL AND ARCHITECTURAL CEILING PLANS.
D I R E C T I O N S
A I R O U T L E T S
EXHAUST AIR LOUVER (WEATHER PROOF)
FIRE RATED EXHAUST GRILLES FOR STORES
EL
FEg
IN-LINE EXHAUST FAN
I-EF
E Q U I P M E N T
DESIGNATION
FIRE RATED EXHAUST GRILLES FOR PARKING
KITCHEN HOOD WITH RE-CIRCULATING FAN
KHRF
OUTDOOR UNIT
ODU
DOOR/TRANSFER GRILLES
DG/TG
DOOR UNDER CUT
DUC
F/A
FROM BELOWF/B
TO HIGHER LEVELT/HL
AT HIGHER LEVEL@HL
TO BELOWT/B
TO LOWER LEVELT/LL
TO ABOVET/A
OR SYMBOL
ABBREVIATION
S E R V I C E L I N E S
CONDENSATE DRAIN PIPE
REFRIGERANT PIPE
M I S C E L L A N E O U S
TOTAL STATIC PRESSURE
TSP
LITER PER SECOND
LPS
DOOR GRILLE OR LOUVER
DOOR UNDERCUT
A I R O U T L E T S
VOLUME DAMPER
EXHAUST DUCT-IN SECTION
DUCT ELBOW WITH TURNING VANES
DUCT ELBOW
DESIGNATIONSYMBOL
D U C T W O R K
SIZE IS IN mm
DUCT SIZE : 1st FIGURE SIDE SHOWN, 2nd FIGURE SIDE NOT SHOWN, EXHAUST AIR LOUVER
EXHAUST AIR GRILLE
THERMOSTAT
CASSETTE FAN COIL UNIT
CAS
PARKING EXHAUST AIR FAN
PEF
VD
VOLUME DAMPER
PASSCAL
PA
11. ACCESS DOORS SHALL BE PROVIDED IN DUCT WORK FOR EASY CLEANING OF
WHOLE SYSTEM AS PER APPROVED STANDARD RECOMMENDATION.
PROVIDE 300x250mm ACCESS DOOR ON BASEMENT MAIN BRANCH DUCTS OF
SIZE 450x300mm EVERY 6 METER FOR CLEANING
WINDOW MOUNTED AXIAL EXHAUST FAN
WMEF
EGp
AND WORKSHOPS
C.D.P.
FRESH AIR LOUVER
EXHAUST GRILLES FOR LABORATORIES
Eg
FIL
INLET AIR LOUVER (WEATHER PROOF)
FRESH AIR SUPPLY GRILLES FOR STORES
Sg
AND WORKSHOPS
IN-LINE SUPPLY FAN
I-SF
MECHANICAL NOTES,SYMBOLS AND ABBREVIATIONS
SCALE: 1:100
M-000
M E
C H
A N
I C
A L
N O
T E
S S
Y M
B O
L E
S
A
N D
A B
B R
E V
I A
T I O
N S
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
UP UP
U P
D N
U P
D N
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
FLOOR FINISH
LEVEL
-3.57 m
FLOOR FINISH
LEVEL
-3.57 m
FLOOR FINISH
LEVEL
-3.57 m
ENG MAINTENANCE
WORKSHOP
B05
47.5 SM
BIOMEDICAL
WORKSHOP
B08
ENG
UNIT STORE
B06
25.0 SM
PARKING
B01
854.0 SM
BULK
STORE
B02
127.0 SM
POWER
BACKUP
B09
55.0 SM
MECHANICAL
RM
B10
67.4 SM
STAIR
B03
15.8 SM
LOAD UNLOAD
BAY
B04
57.5 SM
VEHICULAR ACCESS
RAMP
B01'
260.0 SM
STAIR
B11
15.8 SM
EL RM
B02'
8.4 SM
EGp-1: 350x350
235Lps
EGp-1: 350x350
235Lps
EGp-1: 350x350
235Lps
350x200
235Lps
350x300
470Lps
350x200
235Lps
VD
VD
VD
450x300
705Lps
350x200
235Lps
350x200
235Lps
VD
VD
VD
VD
400x175
235Lps
400x175
235Lps
400x175
235Lps
EGp-1: 350x350
235Lps @LL
600x300
1175Lps
600x350
1410Lps
700x350
1645Lps
VD
350x200
235Lps
700x400
1880Lps
VD
VD
350x200
235Lps
350x300
470Lps
350x200
235Lps
VD
450x300
685Lps
450x350
920Lps
VD
EGp-1: 350x350
235Lps @LL
EGp-1: 350x350
235Lps @LL
400x175
235Lps
VD
400x175
235Lps
550x350
1155Lps
600x350
1390Lps
VD
VD
EGp-1: 350x350
235Lps @LL
EGp-1: 350x350
235Lps
EGp-1: 350x350
235Lps
350x200
235Lps
800x400
2350Lps
400x175
235Lps
450x350
920Lps
950x450
3740Lps
EGp-1: 350x350
235Lps
EGp-1: 350x350
235Lps
EGp-1: 350x350
235Lps @LL
EGp-1: 350x350
235Lps @LL
250x250
270Lps
FlL-1: 400x400
Sg-2: 250x250
100Lps,Ø200 Tip
VD
150x150
80Lps
FEg-2: 200x200
80Lps
VD
FEg-1: 150x150
30Lps
100x100
30Lps
Sg-2: 250x250
FEg-2: 200x200
60Lps
200x200
132Lps
125x125
38Lps
VD
VD
VD
200x150
94Lps
100x100
30Lps
150x150
45Lps
FEg-1: 150x150
15Lps
VD
200x200
185Lps
300x200
215Lps
215Lps
I-SF/1
200x200
170Lps
VD
100x100
30Lps
VD
125x125
38Lps
VD
200x200
90Lps
200x200
170Lps
200x150
100Lps
FEg-1: 150x150
30Lps
Sg-1: 150x150
Sg-1: 150x150
EGp-1: 350x350
235Lps @LL
400x175
235Lps
EGp-1: 350x350
235Lps @LL
400x175
235Lps
100x100
15Lps
94Lps,Ø200 Tip
38Lps,Ø125 Tip
200x200
170Lps
38Lps,Ø125 Tip
150x150
60Lps
MECHANICAL PLAN BASEMENT FLOOR1
SCALE: 1:100
PLAN
NORTH
M-101
M E
C H
A N
I C
A L
P
A
N
B A
S E
M E
N T
F
O
O R
FINAL
1 PARKING EXHAUST AIR FAN
KEYED NOTES
50mmØ STEEL EXHAUST PIPE FOR FIRE DIESEL
PUMP.
IN-LINE FRESH AIR SUPPLY FAN
LOWER LEVEL PARKING EXHAUST GRILL
DETAIL IS SHOWN ON DRAWING NO. M-11O
300x250mm ACCESS DOOR ON DUCT
CIVIL AND STRUCTURAL DETAIL OF PARKING
EXHAUST DUCT RUNNING CHANNEL OUTSIDE
BASEMENT IS SHOWN ON DRAWING NO. C-131
C-133 AND S-903.
THE SUPPLY FAN SHALL BE INTERLOCKED WITH
FIRE ALARM SYSTEM FOR SWITCHING OFF DURING
FIRE.
DETAIL OF STACK SUPPORT,GOOSENECK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111.
250mmØ INSULATED GENERATOR EXHAUST PIPE
PIPE SHALL PIERCE THE WALL AND RISE UP INTO
RAISED PLANTING. EXTEND 0.5METERS ABOVE
GRADE.TERMINATE WITH TWO ELBOWS POINTING
DOWNWARD.
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO.S-102 & S-103
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO.S-102 & S-103
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
FLOOR FINISH
LEVEL
0.00 m
FLOOR FINISH
LEVEL
0.00 m
FLOOR FINISH
LEVEL
0.00 m
SECURITY
10.5 SM
DUITY
RM
12.5 SM
DISTRIBUTION
OFFR
15.1 SM
COMMUNICATION
RM
11.9 SM
RELEASE RM
RED CELL
19.5 SM
DISTRIBUITON
15.5 SM
WAITING
AREA
9.7 SM
RELEASE FREEZER
FOR PLASMA
17.5 SM
RELEASE STORE
PLATLATES
19.0 SM
MEETING
RM
16.7 SM
BLEEDING
RM
95.1 SM
LOBBY
119.5 SM
DONORS REST
RM
19.5 SM
INTERVIEW
9.2 SM
INTERVIEW
9.6 SM
EXAM
RM
10.5 SM
EXAM
RM
10.5 SM
HOMOGLOBIN
CHECKING
12.8 SM
REGISTRATION
24.7 SM
CORR
39.5 SM
WAITING
72.4 SM
CHANGING.M
7.5 SM
TOILET M
9.0 SM
TOILET F
9.0 SM
CORR
11.2 SM
JAN RM
4.2 SM
CHANGING. F
8.3 SM
DONOR'S
CAFE
56.5 SM
STAIR
19.0 SM
STAIR
15.6 SM
ACC
TOILET F
4.2 SM
ACC
TOILET M
4.2 SM
STAFF
RM
11.0 SM
CORR
33.0 SM
COUNCLING
POST DONATION
7.8 SM
DONOR'S
DATA RM
9.5 SM
RECEPTION
4.5 SM
AUTOCLAVE
ROOM
EL RM
3.8 SM
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
UP
U P
D N
D N
U P
U P
D N
80lt
WH
80lt
WH
DP
DP
DP
DP
DP
DP
DP
D
P
D
P
FHR
FE
FHR
FE
FHR
FEFE
CAS -2
TT
RBM-BY53E
WMEF-1
WMEF-1
CAS -2
25mm C.D.P. 25mm
25mm C.D.P.
Ø9.52
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø15.88
25mm C.D.P.
F/HL & T/B
32mm C.D.P.
F/A & T/B
Ø9.52
Ø15.88
FOR REFRIGERANT
DRAWING NO. M-108
Ø9.52
Ø15.88
RISER PIPE SIZE REFER
150x150
60Lps
Eg-2: 200x200
60Lps,Ø150Tip
Dg-2: 400x300
60Lps
El-1: 200x200
60Lps
I-EF/1
STORE
5.6 SM
KITCHEN
10.5 SM
MECHANICAL PLAN GROUND FLOOR
SCALE: 1:100
PLAN
NORTH
M-102
M E
C H
A N
I C
A
N
G R
O U
O
O R
FINAL
KEYED NOTES
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
4 250mmØ INSULATED GENERATOR EXHAUST PIPE
WINDOW MOUNTED TOILET EXHAUST FAN
2 INSULATED REFRIGERANT PIPES
1 CASSETTE TYPE AIR CONDITIONG UNIT
CONDENSATE DRAIN PIPES SHALL DISCHARGE
TO PLANTERS AT GROUND LEVEL.
DETAIL OF STACK SUPPORT,GOOSENECK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111.
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO. S-102 & S-103
IN-LINE EXHAUST FAN
LEVEL
3.57 m
QUAR COOL RM
PLASMA
14.0 sm
FREEZING
PLASMA
14.0 sm
QUARENTINE
PLASMA
37.5 sm
LOBBY
34.5 sm
JAN RM
4.2 sm
BLOOD IRRADIATION
WASHING/PATHOGEN
25.8 sm
CORR
56.4 sm
CHANGING
M
9.0 sm
CHANGING
F
10.2 sm
STAIR
15.8 sm
LAB MANAGER
/ LAB TECHNICAL MANAGER
43.3 sm
OFF
CEN SER
19.5 sm
STAIR
15.6 sm
CORR
57.3 sm
WORK RM
9.5 sm
QUARENTINE
PLATLATES
11.0 sm
SAMPLE RECIPT/
REGISTRATION
23.8 sm
COMPONENT
PREPARATION
151.5 sm
BLOOD GROUP
TESTING
76.0 sm
SERIOLOGY
14.2 sm
NUCL ACID
TESTING
32.8 sm
IDT OFF
VIRIOLOGY
13.0 sm
IDT OFF
SCIENTISTS
14.0 sm
TOILET M
9.0 sm
TOILET F
9.1 sm
CORR
11.2 sm
ACC
TOILET F
4.2 sm
ACC.
TOILET M
4.2 sm
INFECTIOUS
WASTE
10.0 sm
TRANSITION
5.2 sm
INFECTIOUS DISEASES
TESTING LAB
61.0 sm
EL RM
3.8 SM
T
CAS -1 CAS -1
CAS -1CAS -1
T
T
T
RBM-BY53E
WMEF-1 WMEF-1
RBM-BY53E
RBM-BY103E
25mm C.D.P.
25mm C.D.P.
Ø12.7
Ø22.22
Ø6.53
Ø12.7
Ø6.53
Ø12.7
Ø6.53
Ø12.7
Ø6.53
Ø12.7
Ø9.53
Ø15.88
Ø9.53
Ø15.88
150x150
60Lps
300x150
210Lps
200x150
105Lps
200x150
105Lps
200x200
130Lps
500x400
1165Lps
VD
VD
VD VD
VD
VD
VD
VD
25mm C.D.P.
2xDg-3: 400x400
Dg-3: 400x400
115Lps
2x105Lps
2xDg-3: 400x400
2x130Lps
2xDg-4: 550x400
2x260Lps
2xFIL-3: 750x750
2x583Lps
2xDg-2: 400x300
60Lps
Eg-2: 200x200
60Lps,Ø150 Tip
Eg-3: 250x250
105Lps,Ø200Tip
Eg-3: 250x250
130Lps,Ø200 Tip
Eg-5: 400x00
260Lps,Ø300 Tip
300x250
340Lps
I-EF/3
Eg-3: 250x250
105Lps,Ø200Tip
Eg-3: 250x250
115Lps,Ø200Tip
Eg-3: 250x250
130Lps,Ø200 Tip
Eg-5: 400x400
260Lps,Ø300 Tip
El-3: 1200x400
1165Lps
VD
VD
Eg-3: 250x250
130Lps,Ø200 Tip
Eg-2: 200x200
90Lps,Ø175Tip
Eg-1: 150x150
50Lps,Ø150 Tip
Eg-1: 150x150
40Lps,Ø125 Tip
200x200
130Lps
300x300
260Lps
300x300
320Lps
300x300
260Lps
350x300
580Lps
200x200
130Lps
200x200
115Lps
Dg-3: 400x400
130Lps
Ø12.7
Ø22.22
150x150
50Lps
250x250
310Lps
125x125
40Lps
VD
200x150
90Lps
El-2: 400x400
310Lps
I-EF/2
FIL-2: 600x600
310Lps
25mm C.D.P.
Dg-2: 400x300
90Lps
250x200
220Lps
32mm C.D.P.
F/A & T/B
FOR REFRIGERANT
DRAWING NO. M-108
RISER PIPE SIZE REFER
VD
Ø12.7
Ø22.22
Dg-1: 400x200
50Lps
Dg-1: 400x200
40Lps
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
U P D
N
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N l t
W H l t
W H
FHR
MECHANICAL PLAN FIRST FLOOR1
SCALE: 1:100
PLAN
NORTH
M-103
M E
C H
A N
I C
A
N
F I R
S
O
O R
FINAL
KEYED NOTES
IN-LINE EXHAUST FANS
3 WINDOW MOUNTED TOILET EXHAUST FAN
INSULATED REFRIGERANT PIPES
1 CASSETTE TYPE AIR CONDITIONG UNIT
250mmØ INSULATED GENERATOR EXHAUST PIPE
DETAIL OF STACK SUPPORT,GOOSENECK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111
FRESH AIR INLET LOUVERS SHALL BE COORDINATED
WITH ARCHITECTURAL DETAIL
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO. S-102 & S-103
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
7.14m
JAN RM
4.2 SM
CORR
11.2 SM
LOBBY
34.4 SM
MOLECULAR LAB
42.0 SM
DARK
RM
10.0 SM
SERIOLOGY
LAB
45.7 SM
QUALITY MANAGMENT
LAB
61.0 SM
MOBILE TEAM GADGET &
EQUIPIPMENT STORE
35.0 SM
POOL OFF
TELE RECRUITER
138.0 SM
MOBBILE TEAM
MANAGER
22.5 SM
CLINICAL SERVICE
21.4 SM
LAUNDRY
RM
21.9 SM
CORR
52.8 SM
CORR
60.0 SM
CHANGING
M
9.0 SM
CHANGING
F
10.2 SM
SAMPLE LAB
25.0 SM
DOCUMENTATION
REGISTRATION AND REPORT
36.0 SM
TOILET M
9.0 SM
TOILET F
9.1 SM
STERILIZATION AND
AUTOCLAVE
41.0 SM
SOLID PHASE LAB
29.2 SM
STAIR
15.8
STAIR
19.0 SM
SERVICE
13.5 SM
ACC
TOILET F
4.2 SM
ACC
TOILET M
4.2 SM
DONOR RECRUITERS &
MOBILE COLLECTION TEAM CORD
50.0 SM
EL RM
3.8 SM
T
CAS -4
CAS -3
CAS -3
Ø9.53
Ø15.88
T
T
RBM-BY103E
RBM-BY103E
25mm C.D.P.
FOR REFRIGERANT
DRAWING NO. M-108
WMEF-1 WMEF-1
25mm C.D.P. F/A
Ø9.53
Ø15.88
Ø9.53
Ø15.88
Ø12.7
Ø22.22
Ø12.7
Ø22.22
200x150
85Lps
250x200
190Lps
350x350
675Lps
Eg-2 200x200
85Lps,Ø175 Tip
Eg-3: 250x250
105Lps,Ø200 Tip
VD
VD
VD
VD
225x225
145Lps
200x150
105Lps
225x225
145Lps
VD
125x125
35Lps
VD
Eg-4: 300x300
145Lps,Ø225 Tip
Eg-4: 300x300
160Lps,Ø225 Tip
Eg-1: 150x150
35Lps,Ø125 Tip
Dg-2: 400x300
85Lps
Dg-3: 400x400
105Lps
Dg-2: 400x300
80Lps
Dg-4: 550x400
180Lps
FIL-3: 750x750
675Lps
Dg-3: 400x400
145Lps
El-4: 800x400
675Lps
I-EF/4
Dg-2: 400x300
80Lps
Eg-4: 300x300
145Lps,Ø225 Tip
225x225
180Lps
& 32mm T/B
32mm C.D.P.
225x225
160Lps
300x300
495Lps
25mm
RISER PIPE SIZE REFER
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
D N
U P
U P
D N l t
W H l t
W H
MECHANICAL PLAN SECOND FLOOR
SCALE: 1:100
PLAN
NORTH
M-104
M E
C H
A N
I C
A
N
S E
C O
O
O R
FINAL
KEYED NOTES
WINDOW MOUNTED TOILET EXHAUST FAN
2 INSULATED REFRIGERANT PIPES
1 CASSETTE TYPE AIR CONDITIONG UNIT
250mmØ INSULATED GENERATOR EXHAUST PIPE
DETAIL OF STACK SUPPORT,GOOSENECK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111
FRESH AIR INLET LOUVERS SHALL BE COORDINATED
WITH ARCHITECTURAL DETAILS
IN-LINE EXHAUST FAN
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO. S-102 & S-103
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
JAN RM
4.2 sm
LOBBY
30.0 sm
CORR
75.0 sm
PROCUREMENT MANAGER
PROC.SUPPLY
35.0 sm
IT
SERVER
19.0 sm
DOCUMENT
STORE
8.5 sm CORR
22.0 sm
CORR
27.5 sm
MEETING HALL
286.5 sm
GENERAL
SECRETARY
21.5 sm
DEPUTY DIRECTOR
22.5 sm
GENERAL DIRECTOR
30.6 sm
KITCHEN
14.7 sm
DEPUT DIRECTOR
OPPERATION WING
32.7 sm
BLOOD TRANSFUSION
SERVICE MANAGER/ RECORDS
18 sm
HUMAN
RESOURCE
12.3 sm
IT
MANAGER
12.3 sm
FINANCE
DEPARTMENT
20.0 sm
STAIR
15.8 sm
QUALITY MANAGMENT
DEPARTMENT
19.0 sm
TRAINING RM/
LIBRARY
43.5 sm
ARCHIVE
15.5 sm
LEGAL/ GENDER
AFFAIRS
25.8 sm
STAIR
15.6 sm
TOILET M
9.0 sm
TOILET F
9.1 sm
CORR
11.2 sm
ACC.
TOILET F
4.2 sm
ACC.
TOILET M
4.2 sm
EXECUTIVE
SECRETARY
14.5 sm
EL RM
3.8 SM
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
T
T
25mm C.D.P. T/B
CASCAS
Ø9.53
Ø15.88
25mm C.D.P.
3WMEF-1
WMEF-1
FROM ODU-1
Ø9.53
Ø15.88
Ø9.53
Ø15.88
Ø9.53
Ø15.88
Ø9.53
Ø15.88
Ø9.53
Ø15.88
Ø9.53
Ø15.88
FOR REFRIGERANT
RISER PIPE SIZE REFER
DRAWING NO. M-108
FROM ODU-2
WMEF-1
ENGINEERING
DEPARTMENT
16.0 sm
MECHANICAL PLAN THIRD FLOOR1
SCALE: 1:100
PLAN
NORTH
M-105
M E
C H
A N
I C
A
N
T H
I R
D
F
L O
O R
FINAL
KEYED NOTES
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
WINDOW MOUNTED TOILET EXHAUST FAN
2 INSULATED REFRIGERANT PIPES
1 CASSETTE TYPE AIR CONDITIONG UNIT
250mmØ INSULATED GENERATOR EXHAUST PIPE
DETAIL OF STACK SUPPORT,GOOSENEK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO. S-102 & S-103
15.28 m
FLOOR FINISH
LEVEL
14.28 m
STAIR
15.8 SM
MAINTENANCE
15.8 SM
MACHINE RM
6.8 SM
EGA SHEET
EGA SHEET
EGA SHEET
EGA SHEET
12%
SLOPE
12%
SLOPE
12%
SLOPE
12%
SLOPE
STAIR
19.0 SM
Ø15.88
Ø35
Ø9.53
Ø15.88
ODU-2
ODU-1
Ø9.53
Ø15.88
INSULATED REFRIGERANT
PIPES T/B
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
RD
R
D
MECHANICAL PLAN-LIFT ROOM & ROOF ACCESS1
SCALE: 1:100
PLAN
NORTH
M-106
M E
C H
A N
I C
A
N L
I F
T
R O
O M
R
O
F
A
C C
E S
S
FINAL
KEYED NOTES
SERVER ROOM OUTDOOR UNITS
GROUND,FIRST AND SECOND FLOOR
SELECTED ROOMS AIR CONDITIONING
OUTDOOR UNITS
INSULATED REFRIGERANT PIPES
IF THERE IS AN OBSTACLE AT THE UPPER
SIDE OF THE OUTDOOR UNIT,SET THE TOP
END OF THE OUTDOOR UNIT 2000mm
APART FROM THE OBSTACLE
LIMIT THE HEIGHT OF THE OBSTACLE
SURROUNDING THE OUTDOOR UNIT TO
800mm OR LESS FROM THE BOTTOM END
OF THE OUTDOOR.
250mmØ INSULATED GENERATOR EXHAUST PIPE w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
DETAIL OF STACK SUPPORT,GOOSENECK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111
STRUCTURAL DETAIL OF OPENING IS SHOWN ON
DRAWING NO. S-102 & S-103
ROOF
1428.0 cm
ROOF
LEVEL
1698.0 cm
ROOF
LEVEL
1698.0 cm
12%
SLOPE
S L
O P
E
S L
O P
E
S L
O P
E
EGA
SHEET
EGA
SHEET
EGA
SHEET
12%
SLOPE
12%
SLOPE
2%
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
RD
RD
RD
RD RD RD
RD
R
D
R
D
ODU-2
ODU-1
Ø15.88
Ø35
Ø9.53
Ø15.88
Ø9.53
Ø15.88
MECHANICAL ROOF PLAN1
SCALE: 1:100
PLAN
NORTH
M-107
E C
H A
N I C
O
F
P
L A
N
FINAL
SERVER ROOM OUTDOOR UNITS
GROUND,FIRST AND SECOND FLOOR
SELECTED ROOMS AIR CONDITIONING
OUTDOOR UNITS
KEYED NOTES
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
INSULATED REFRIGERANT PIPES
IF THERE IS AN OBSTACLE AT THE UPPER
SIDE OF THE OUTDOOR UNIT,SET THE TOP
END OF THE OUTDOOR UNIT 2000mm
APART FROM THE OBSTACLE
LIMIT THE HEIGHT OF THE OBSTACLE
SURROUNDING THE OUTDOOR UNIT TO
800mm OR LESS FROM THE BOTTOM END
OF THE OUTDOOR.
250mmØ GENERATOR EXHAUST PIPE
DETAIL OF STACK SUPPORT,GOOSENECK AND
PIPE ALIGNMENT IS SHOWN ON DRAWING NO.
M-111
STRUCTURAL DETAIL OF OPENING IS SHOWN
ON DRAWING NO. S-102 & S-103
MMY-MAP2411T8
MMY-MAP1201T8
0.6m
RBM-BT13E
OIL - Ø9.52
MMY-MAP1201T8
1.2m
8.0m
RBM-BY203E
1.5m
Ø28.6
Ø15.88
4.0m
RBM-BY103E
27.0m
41.5m
RBM-BY103E
Ø15.88
Ø9.52
9.0m
1.5m
RBM-BY53E
4.5m
10.0m
RBM-BY103E
1.0m
5.5m
MMU-AP0271H (3)
5.90 kW / 4.74 kW
MMU-AP0271H (3)
5.90 kW / 4.74 kW
RBM-BY53E
3.9m
3.9m
RBM-BY53E
3.5m
4.5m
MMU-AP0151H (1.7)
3.32 kW / 2.67 kW
MMU-AP0151H (1.7)
3.32 kW / 2.67 kW
MMU-AP0151H (1.7)
3.32 kW / 2.67 kW
MMU-AP0151H (1.7)
3.32 kW / 2.67 kW
RBM-BY103E
7.5m
2.5m
MMU-AP0361H (4)
8.27 kW / 6.64 kW
MMU-AP0301H (3.2)
6.64 kW / 5.34 kW
MMU-AP0301H (3.2)
6.64 kW / 5.34 kW
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø22.22
Ø12.7
Ø12.7
Ø6.35
Ø12.7
Ø6.35
Ø15.88
Ø9.52
Ø12.7
Ø6.35
Ø12.7
Ø6.35
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø15.88
Ø9.52
Ø22.22
Ø12.7
Ø22.22
Ø12.7
Ø35
Ø15.88
Ø28.6
Ø12.7
Ø28.6
Ø12.7
VRF AIR CONDITIONING SYSTEM SCHEMATIC1
SCALE: 1:100
M-108
V R
F
A
I
N
D I T
I O
N I N
G
S Y
S T
H
E M
A T
I C
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
4. FANS
EXHAUST AIR FANS CAPACITY
REFE.NUM
SYSTEM
LPS
CAPACITY
EXT. STATIC
TYPE
KW
MODEL
MOTOR DATA
VOLTS PHASE HZ
7.0
DYN AIR or Equivalent
QTY
0.25
3740 - 6900
LOCATION
5. SUPPLY AND EXHAUST AIR GRILLES
REFE.NUM
EXHAUST AIR GRILLS
CAPACITY
Liter/sec.
TYPE
MODEL
DESCRIPTION
SIZE
mmxmm
QTY
15,30
FEg-1
-EGp-1
150x150
350x350
Fire rated Exhaust air grille
WORKSHOP & STORES
TWO SPEED FAN (BOX-T HT type)
PEF-1
Note :
3. SPLIT AIR CONDITIONING UNITS
1:1
OUTDOOR&INDOOR
COMBINATION
TOTAL COOLING LOAD
YORK
EQUIVALENT
OR
CONNECTION
Dia. 15.88
0.03
I-EF/1
[KW]
MODEL
INDOOR UNIT OUTDOOR UNIT
ELECTRICAL DATA
VOLTSKW* PHASES HZ
230 1 50
TYPE
2 9.3 YHKJXH 36
WMEF-1
WINDOW MOUNTED FAN
PRESSURE(Pa)
ELECTRICAL DATA
ELECTRICAL DATA
YHUJXH 36
Dia. 9.52
QTY
FEg-2
60,80 200x200
Nailor or
CAR PARKING
Equivalent
VENTS or Equivalent
VENT150MA01 turbo
EG-2
60,80,85,90 200x200
EG-3
105,115,130 250x250
EG-4
145,160 300x300
Exhaust air grille
Fire rated Exhaust air grille
EG-1 FIRST AND SECOND FLOORS LAB.
35,40,40
150x150
I-EF/2
I-EF/3 945
0.75
0.5 - - -
LOCATION
6. DOOR/TRANSFER GRILLES
REFE.NUM
CAPACITY
Liter/sec.
TYPE
MODEL
DESCRIPTION
SIZE
mmxmm
QTY
60,80,85,90
Dg-2
400x300
Dg-3
Dg-4
180,260
105,115,130
550x400
400x400
Nailor or
Equivalent
DOOR/TRANSFER GRILLES
LOCATION
7. WEATHER PROOF SUPPLY AND EXHAUST AIR LOUVERS
REFE.NUM
CAPACITY
Liter/sec.
TYPE
MODEL
DESCRIPTION
SIZE
mmxmm
QTY
400x400
800x400
Nailor or
Equivalent
1200x400
SUPPLY AND EXHAUST AIR LOUVERS
EL-2
EL-3
SECOND FLOOR
FIRST FLOOR
IN-LINE FAN (AxB type)
EL-4
FIRST FLOOR
I-EF/4
IN-LINE FAN (AxB type)
IN-LINE FAN (AxB type)
IN-LINE FAN (AxB type)
0.1
EL-1
GROUND FLOOR
Exhaust air louver
200x200
600x600
FIL-2
FIRST FLOOR
750x750
583,675
FIL-3
FIRST AND SECOND FLOOR
Dg-1
Double Flange Door grilles
FIRST AND SECOND FLOORS LAB.
400x200
40,50
FIRST AND SECOND FLOORS LAB.
GROUND - SECOND FLOORS LAB.
EG-5
260 400x400
SUPPLY AIR FANS CAPACITY
0.3 - - --
I-SF/1
IN-LINE FAN (AxB type)
DYN AIR or Equivalent
SUPPLY AIR GRILLS
Supply air grille
Sg-1
38 -
150x150
Sg-2 94,100
250x250
WORKSHOP & STORES
Nailor or
Equivalent
400x400
FIL-1
Inlet air louver
BASEMENT FLOOR
MECHANICAL EQUIPMENT SCHEDULE1
SCALE: 1:100
M-109
M E
C H
A N
I C
Q U
I P
M E
N T
S C
H E
D U
L E
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
HEMMED "S" SLIP
FLANGED
(CAULK OR GASKET)
DRIVE SLIP
DUCT CONSTRUCTIONS (Follow SMACNA recommendation)
STANDING SLIP
STANDING SEAM
MECHANICAL DETAIL-1
SCALE: 1:100
M-110
M E
C H
A N
I C
T
A I L
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
EXHAUST AIR DUCT
DUCT COLLAR
STYROFOAM PAD CONCRETE BASE
FLOOR/ROOF SLAB
FLEXIBLE CONNECTION
CONSTRUCTION REF:
ARCH. & STRUC.
DRAWINGS.
CHASE
WATERPROOF JOINTS
WELDED AS REQUIRED
ANGLE, RIVETED OR TACK
MESH BIRD SCREEN
GALVANIZED STEEL
12mm x 12mm x 1.3mmØ
R=DIA/2
GOOSENECK - FACE IN DIRECTION
135°
INSULATION
250mmØ 4.3mm BLACK STEEL(WELDED)
CHASE
75mm AIR GAP
INSULATION
GENERATOR EXHAUST PIPE
SPLIT-RING
PIPE CLAMP
SPLIT-RING
PIPE CLAMP
DO NOT
TIGHTEN TO
PIPE CLAMP
15mm ROD
SECURE CLAMP
INSULATION
AROUND
ROOF
SECURE TO VENT
THIMBLE COLLAR
HIGH TEMPERATE
SEALANT
VENT STORM COLLAR
HOOD 2.75mm
VENT FLASHING (3.5mm
COUNTER FLASHING)
EXTEND ROOFING
UNDER COUNTER
FLASHING
SECURE 15mm
CONCRETE
ROD IN
EDGE OF SLAB
OF PREVAILING WIND
WIND
MATCH HEIGHT
OF PARAPET
(FIRE-WRAP)
250mmØ 4.3mm BLACK STEEL
GENERATOR EXHAUST PIPE
(FIRE-WRAP)
75mm AIR GAP
NEOPRENE PAD
GENERATOR
INSULATION
EXHAUST
250mmØ 9.3mm
"T" FITTING
BLACK STEEL
10mm BLACK
STEEL PLATE
CONNECTIONS
WELD ALL PIPE
125mmØ CLEANOUT
250mmØ 9.3mm
"T" FITTING
BLACK STEEL
INSULATION
10mm BLACK STEEL
REMOVEABLE
CLEANOUT PLATE
10mm BLACK STEEL
REMOVEABLE
CLEANOUT PLATE
15mmØ REMOVEABLE
THREADED RODS
WELD "T" FITTING
TO STEEL PLATE
SUPPORT AT FLOOR
15mmØ REMOVEABLE
THREADED RODS
10mm BLACK
STEEL PLATE
TO FLOOR (TYPICAL
EACH CORNER)
STEEL SUPPORTS
PROVIDE CROSS-
BRACING AS
REQUIRED
A
NOTE
* PROVIDE BELLOWS TYPE EXPANSION COMPENSATOR
BETWEEN THE GENERATOR AND EXHAUST PIPE
MECHANICAL DETAIL-2
SCALE: 1:100
M-111
M E
C H
A N
I C
T
A I L
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
MBG
H
I
FACP
I
AC
D
HD
SH
D
SD
SP
TEL
TV
EMH
TMH
MDF
PBX
CS
T
E-000
E L
E C
T R
I C
Y M
B O
L S
A N
D
N
O T
E S
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
GENERAL NOTES
1. POWER SUPPLY LINES WHICH ARE PART OF THE SITE ELECTRICAL
POWER DISTRIBUTION SYSTEM, FROM POLE OR TRANSFORMER TO
THE MAIN DISTRIBUTION BOARD, COMPOUND LIGHTING FROM POLE
TO POLE SHALL BE INSTALLED UNDERGROUND, WARNING TAPE
SHALL BE INSTALLED ABOVE
2. USE OF EXISTING ELECTRIC MANHOLE TO THE COMPOUND LIGHT IS
PROHIBITED
3. PLASTIC EXTRUDED WIRE TRAY SIZE 25 X 25MM SHOULD BE
INSTALLED IN ELECTRIC DISTRIBUTION BOARDS
POWER NOTES
1. ELECTRICAL INSTALLATION IN INTERNAL WALL AND SLAB SHALL BE
CONTAINED INSIDE RIGID CONDUIT
2. CONFIRM TYPE AND GET APPROVAL TO ALL UNSPECIFIED POWER
APPLIANCES
3. ALL OUTLET CIRCUIT BREAKER SHALL BE GFCI PROTECTED
4. ALL OUTLET INSTALLATIONS AT WATER CLOSETS, SHOWERS, SINKS
AND OTHER WET AREAS SHALL BE WATERPROOF/COVERED
5. OUTDOOR INSTALLATIONS SHALL BE WEATHERPROOF
6. INSTALL CONDUITS FOR OUTLETS IN SLAB SCREED WHERE
REQUIRED
7. FOLLOW TN-S SYSTEM (THREE PHASE + NEUTRAL + EARTH) IN ALL
INSTALLATIONS.
8. PRIOR TO COMMENCEMENT OF WORK, VERIFY THE FOLLOWING:
8.1. LOAD BALANCE ON PHASES
8.2. IP-CLASS IN DIFFERENT LOCATIONS
9. PROTECT ALL CABLES FROM MECHANICAL DAMAGE
10. REF DRAWING FOR TYP EARTHING DETAIL
11. SOCKET OUTLETS SHALL BE AT 500MM FROM THE FINISHED FLOOR
LEVEL
12. AUXILIARY SYSTEMS
12.1. ALL SYSTEM WIRING AND CABLING TO BE DONE ACCORDING TO
SYSTEM SUPPLIER AND ACCORDING TO LOCAL AUTHORITY
REQUIREMENTS
12.2. COMPLETE APPROVED OPERATIONAL SYSTEM TO BE PROVIDED
BY A SINGLE MANUFACTURER
12.3. ADJUST FINAL LOCATION AND INSTALLATION OF ALL AUXILIARY
SYSTEMS ACCORDING TO SUPPLIER RECOMMENDATION
LIGHTING NOTES
1. INSTALLATION METHOD IN CONCRETE, ABOVE CEILING, OR IN SLAB
AS INDICATED ON THE DRAWINGS AND SPECIFICATIONS
2. LIGHT FITTINGS TO BE FLUSH MOUNTED, UNO, EXCEPT AT
SUSPENDED CEILINGS, WHERE THEY ARE TO BE SUSPENDED IN
CEILING SYSTEM
3. PRIOR TO COMMENCEMENT OF THE NBTS BUILDING CONSTRUCTION,
VERIFY THE FOLLOWING:
3.1. LOAD BALANCE ON PHASES
3.2. IP-CLASS IN DIFFERENT LOCATIONS
4. REF DRAWINGS FOR STD LUMINAIRE INSTALLATION DETAILS
5. PROVIDE ACCESS TO ALL JUNCTION BOXES AND APPLIANCES
INSTALLED ABOVE CEILING, COORDINATE WITH CEILING SYSTEM
6. CONDUIT SUPPORTS ARE TO BE USED FOR INSTALLATIONS ABOVE
CEILING AND WHENEVER INSTALLATION IS TO BE DONE ON WALL OR
BEAM SURFACES, CONDUITS SHOULD BE BURIED
7. LIGHT SWITCHES SHALL BE AT 1200MM FROM THE FINISHED FLOOR
LEVEL AND 150MM FROM DOOR EDGE, ON OPENING SIDE OF DOOR
8. LABEL SIGNAGE ABOVE SWITCH OF EMERGENCY LIGHT PER WALL
SIGNAGE DETAIL
1. THE PROTECTION ZONE SHALL BE THE WHOLE NBTS
BUILDING
2. IF A STRUCTURE OR COMPOUND VARY CONSIDERABLY IN
HEIGHT, ANY NECESSARY AIR TERMINATION OR AIR
TERMINATION NETWORK FOR THE LOWER PORTIONS SHALL BE
JOINED TO THE DOWN CONDUCTORS OF THE TALLER PORTIONS
IN ADDITION TO BEING JOINED TO THEIR OWN DOWN
CONDUCTOR
3. THE AIR TERMINAL UNIT SHALL POSSES EXCEPTIONAL
ELECTRICAL CHARACTERISTICS, NO ANTENNA AND BEACON
INTERFERENCE, 100KPH SURVIVAL WIND SPEED AND
REPLACEABLE DISSIPATING TIPS
4. VERTICAL AIR TERMINAL SHALL BE MADE OF SOLID 16MM
DIAM COPPER ROD, AND THE INSTALLATION HEIGHT SHALL
ENABLE THE TERMINAL TO PROTECT THE NEARBY OBJECTS
5. AIR TERMINAL STAND IS TO BE FIXED BY 4X10MM BOLT, USE
BOLTED CLAMP MADE OF COPPER TO CONNECT AIR TERMINAL
UNIT WITH DOWN CONDUCTOR
6. DOWN CONDUCTORS SHALL BE 50 MM SQ ROD/STRIP. THE
CONDUCTORS SHOULD TERMINATE AT EARTH RODS, THE
TERMINATION SHALL BE MADE BY CLAMPING AND CLAMPS
SHALL BE SECURED WITH AT LEAST TWO BOLTS AND SHALL
MAKE CONTACT WITH THE EARTH ROD FOR AT LEAST 380MM SQ
7. PROVIDE THREE DOWN CONDUCTORS FOR NBTS BUILDING
8. PROTECT THE DOWN CONDUCTORS FROM MECHANICAL
DAMAGE 2 METERS ABOVE GRADE LEVEL
9. SHARP BEND - NO BEND OF A CONDUCTOR SHALL FORM AN
INCLUDED ANGLE OF LESS THAN 90 DEGREE OR HAVE A RADIUS
OF BEND LESS THAN 203MM
10. EXTERIOR STEEL EXIT STAIR, MECHANICAL DUCTS AND ANY
METAL IN OR FORMING PART OF THE STRUCTURE IN CONTACT
WITH THE EARTH SHALL BE BONDED TO THE AIR TERMINATION
NETWORK OR TO DOWN CONDUCTOR AND EARTHING
CONNECTION SHALL BE MADE TO EACH STEEL COLUMN
AROUND THE PERIMETER
11. INSTALL DIAM 16MM L 3000MM COPPER EARTH ROD AT
600MM FROM THE STRUCTURE IN MANHOLES LOCATED PER
DRAWING AND QUANTITY PER MANUFACTURER
RECOMMENDATION
12. EARTHING RESISTANCE OF THE WHOLE EARTH
TERMINATION NETWORK SHOULD NOT BE GREATER THAN 5
OHMS, IF IT IS GREATER THAN 5 OHMS INSTALL ANOTHER
EARTHING ROD WITHIN A DISTANCE NOT GREATER THAN THE
LENGTH OF THE ROD
13. IF ELECTRIC, TELEPHONE OR OTHER SYSTEMS ARE
EARTHED TO A COMMON TERMINAL, ONE CONNECTION FROM
THE LIGHTNING PROTECTION SYSTEM TO THE COMMON
TERMINAL IS REQUIRED.
LIGHTNING PROTECTION NOTES
ELECTRICAL SYMBOLS AND NOTES 1
CMDB
SDB/PU
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
4E
ENG MAINT
WSHOP
B05
BIOMED
WSHOP
B08
ENG
UNIT STORE
B06
BULK
STORE
B02
MECHANICAL
RM
B10
STAIR
B03
LOAD UNLOAD
BAY
B04
PARKING
B01
VEHICULAR ACCESS
RAMP
B01'
CHEMICAL
STORE
B07
EL RM
B02' b ca b
NOTE
*EXIT SIGNS SHALL BE CIRCUITED
ON AN UN-SWITCHED LEG OF THE
LIGHTING CIRCUIT SERVING THE
AREA.
UPUP
U P
D N
CMDB
CMDB
CMDB
CMDB
CMDB
CMDB
SDB/PU
1 b
1 b
1 b
1 b
1 b
1 b
1 b
1 b
1 b
1 b
1 b
1 a
1 a
1 a
1 a
1 a
1 a
1 a
1 a
1 1 1
4E
4E
4E
1 c
1 c
1 c
1 c
1 c
1 c
CMDB
U P
D N
LIGHTING FLOOR PLAN
BASEMENT1
SCALE: 1:100
PLAN
NORTH
E-101
L I G
H T
I N
G
F
L O
A
N
B A
S E
M E
N T
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
E-102
4E
4E
4E
4E
4 4
8 8
6E
6E
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SDB/GF
SECURITY
12.2 SM
DUITY
RM
DISTRN
OFFR
COMMUNICATION
RELEASE RM
RED CELL
DISTRIBUITON
WAITING
AREA
RELEASE FREEZER
FOR PLASMA
RELEASE STORE
PLATLATES
MEETING
BLEEDING
LOBBY
DONORS REST
STOR
KITCH
INTERVIEW
EXAM
HOMOGLOBIN
CHECKING
REGISTRATION
CORR
CHGNG
TLT M
TLT F
CORR
DONOR'S
CAFE
STAIR
STAIR
ACC
STAFF
CNCLG
P DON
DONOR'S
DATA RM
RECEPTION
AUTOCLAVE
ROOM
EXIT
SWITCH FOR 2ND
FLOOR PENDANT
LIGHT C'C'T' NO 38
6b6b
6b 6b6b
6b 6b
6 6
6a 6a 6a
6a
6a6a6a
6E
6E
6E
6E
6E-b
6E-a
6E 6E 6E
6E
6E
6E
6E6E6E
6E
6E
6E
6E
6E
6E
6a 6a
6 6 6
6 6
6 6
6 66666666
6 6
6 6 6 6 6 6 6
6E
6E
6E
6E a b
7 7
SDB/GF
U P
D N
U P
D N
U P
D N
UP
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
UP
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
DP
SDB/GF
12 SDB/GF
NOTE
1-EXIT SIGNS SHALL BE CIRCUITED ON AN
UN-SWITCHED LEG OF THE LIGHTING
CIRCUIT
2-LIGHT FIXTURES AND FIRE ALARM UNITS
SHOULD BE INSTALLED IN ONE STRAIGHT
LINE. SPECIALLY AT THE CORRIDOR.
3-ANY ONE SINGLE STROKE SWITCH (SINGLE
POLE SWITCH) IS DEDICATED TO CONTROL
EMERGENCY LUMINARIES.
EL
RM
KEY NOTES
SDB/GF
SDB/GF/UPS
PATCH PANEL
4 4
8 8
CHGNG
M
ACC
EXIT
6E
7 7
12 SDB/GF
LIGHTING FLOOR PLAN
GROUND1
SCALE: 1:100
PLAN
NORTH
E-102
L I G
H T
I N
G
F
L O
A
N
G R
O U
N D
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
ENLARGED TOILET AND CHANGING
LIGHTING INSTALATION
SCALE: 1:50
6 6
4E
4E
6 6 6
6 6
6 6
6 6 6 6
6 6 6
6 6 6
6 6
6 6 6
6 6
4E
4E
6 6 6 6
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E 6E
6E
6E
6E
6E
6E
6E
SDB/FF
SDB/FF
SDB/FF
SDB/FF
SDB/FF
SDB/FF
SDB/FF
SDB/FF
SDB/FF
6E
6E
6E6E
6E
6E
6E
6E
66E
QUAR COOL RM PLASMA
FREEZING PLASMA
QUAR.
PLASMA
BLD IRDN
WSHG/PTHGN
CHG. M
CHG. F
STAIR
LAB M./
LAB T MANAGER
OFF
CEN SER
WORK RM
QRTN PLAT
VERIF &
LBNG
S. RECIPT/
REGIS.
COMPONENT
PREPARATION
B. GROUP
TESTING
SCIENTISTS
SERIOLOGY
NUCL ACID
TESTING
IDT OFF
VIRIOLOGY
SCIENTISTS
TLT F
TLT M
INFEC.
WASTE
TRANS
INFECTIOUS DISEASES
TESTING LAB
EL RM
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
U P
D N
G
H
H'
H
H'
G
F
E
D
C
B
A
1 2 3 4 5 6
D
C
B
A
4 5 6
F
E
1 2 3
E'
D'
E-103
NOTE
1-EXIT SIGNS SHALL BE CIRCUITED
ON AN UN-SWITCHED LEG OF
THE LIGHTING CIRCUIT
2-LIGHT FIXTURES AND FIRE
ALARM UNITS SHOULD BE
INSTALLED IN ONE STRAIGHT
LINE. SPECIALLY AT THE
CORRIDOR.
3-ANY ONE SINGLE STROKE
SWITCH (SINGLE POLE SWITCH)
IS DEDICATED TO CONTROL
EMERGENCY LUMINARIES.
SDB/FF
SDB/FF
SDB/FF
SDB/FF
SDB/FF
KEY NOTES
SDB/FF
SDB/FF/UPS
PATCH PANEL
CHG. M
CHG. F
TLT M
TLT F
TLT M
INFEC.
WASTE
TRANS
LIGHTING FLOOR PLAN
FIRST1
SCALE: 1:100
PLAN
NORTH
E-103
L I G
H T
I N
G
F
L O
A
N
F I R
S T
FINAL
w w w t e t r a t e c h c o m
O n e
G r a n t
S t r e e t
F r a m i n g h a m
M
A
ENLARGED TOILET AND CHANGING
LIGHTING INSTALATION2
6 6
6 6
6 6
6 6
6 6
6 6
6 6 6
6 6
6 6
4E
4E
EXIT
6 6
6 6 6
6 6
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
6E
SDB/2F
SDB/2F
SDB/2F
SDB/2F
SDB/2F
SDB
SDB/2F
SDB/2F
SDB/2F
SDB/2F
SDB/2F
SDB/2F
SDB/2F
7 7
8 8
4E
4E
EXIT
EXIT
SDB/2F
SDB/2F
66E
6E
4 4
6E
6E
6E
6 6 6 6
CORR
LOBBY
MOLECUL LAB
DARK
RM
SERIOLOGY
LAB
QLTY MGT
LAB
MOBILE TEAM GADGET &
EQUIPMENT STORE
POOL OFF
TELE RECRU
STAFF
RM
LNDRY
RM
CORR
CORR
SAMPLE LAB
DOC, REG
& REPORT
TLT M
TLT F