Attachment_J.2_-_HC_Prototype_Drawings_-_6_of_6_-_Electrical.pdf

PDF 1 MB Posted

Attached to
National Blood Transfusion Center and 17 Health Centers Construction Project
Solicitation number
SOL-663-16-000001
Issued by

About this file

Attachment J.2 - HC Prototype Drawings - 6 of 6 - Electrical

View the file

Other files

File Type Posted
Amendment_000002_(SF_30_with_Q A)_-_SOL-663-16-000001.pdf PDF
Attachment_J.15_-_AID1420-17_Contractor_Employee_Biographical_Data_Sheet.doc DOC document
Attachment_J.14_-_Geo-technical_Report.pdf PDF
Amendment__000001_full_package.pdf PDF
Attachment_J.5_-_Group_-3_Unpriced_BOQ_Girana_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_2.2_-GERBICHO_SITE_DEVELOPMENT_DWGS.pdf PDF
SOL-663-16-000001.pdf PDF
Attachment_J.6_-_NBTS_-_Drawings_Volume_2_of_2.pdf PDF
Attachment_J.4_-_Health_Centers_-_Specifications_(2015-10-09).pdf PDF
Attachment_J.5_-_Group_-7_Unpriced_BOQ_Gulem_Dejen_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_4.1_-WELELA_BAHER_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.11_-_Past_Performance_Information.docx DOCX document
Attachment_J.1_-_Pricing_Tables.xlsx XLSX spreadsheet
Attachment_J.5_-_Group_-5_Unpriced_BOQ_Lideta_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-6_Unpriced_BOQ_Gult_Health_Center.xls XLS spreadsheet
Attachment_J.8_-_NBTS_-_Quantity_Estimates.pdf PDF
Attachment_J.3_-_Site_5.2_-KUNI_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_3.2_-GIRANA_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_10_-_VAT_Reimbursement_Processes.pdf PDF
Attachment_J.2_-_HC_Prototype_Drawings_-_3_of_6_-_Architectural.pdf PDF
Attachment_J.5_-_Group_-3_Unpriced_BOQ_Gelsha_Health_Center.xls XLS spreadsheet
Attachment_J.7_-_NBTS_-_Specifications.pdf PDF
Attachment_J.5_-_Group_-5_Unpriced_BOQ_Kuni_Health_Center.xls XLS spreadsheet
Attachment_J.12_-_Contractor_Performance_Report_-_Short_Form.pdf PDF
Attachment_J.5_-_Group_-1_Unpriced_BOQ_Lemi_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Progress_Summary.pdf PDF
Attachment_J.3_-_Site_3.3_-GELSHA_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.2_-_HC_Prototype_Drawings_-_4_of_6_-_Structural.pdf PDF
Attachment_J.5_-_Group_-2_Unpriced_BOQ_Gerbicho_Health_Center.xls XLS spreadsheet
Attachment_J.8_-_NBTS_-_Product_Samples.pdf PDF
Attachment_J.5_-_Group_-2_Unpriced_BOQ_Finchawa_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_7.1_-KACHANA_GUDIE_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.5_-_Group_-5_Unpriced_BOQ_Agumamit_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-7_Unpriced_BOQ_Kechena_Gudie_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-2_Unpriced_BOQ_Haro_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-6_Unpriced_BOQ_Maksegnit_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-4_Unpriced_BOQ_Welela_Bahir_Health_Center.xls XLS spreadsheet
Attachment_J.9_-_Umbrella_EMMP_for_EHIP.pdf PDF
Attachment_J.5_-_Group_-4_Unpriced_BOQ_Addis_Bete_Chiristian_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-4_Unpriced_BOQ_Debat_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-3_Unpriced_BOQ_Kulmesk_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_5.3_-GULEM_DEJEN_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_2.3_-HARO_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.6_-_NBTS_-_Drawings_Volume_1_of_2.pdf PDF
Attachment_J.3_-_Site_4.2_-ADDIS_BET_CHRISTIAN_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_2.1_-FINCHAWA_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.5_-_Site_Progress_Tables_-_Available_Materials.pdf PDF
Attachment_J.3_-_Site_6.2_-MAKSEGNIT_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_6.1_-GULT_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_1.2_-LEMI_SITE_DEVELOPMENT_DWGS.pdf PDF
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESCRIPTION

WALL MOUNTED INCANDESCENT

LUMINAIRE

SURFACE SINGLE LAMP FLUORESCENT

LUMINAIRE (1x36W)

SURFACE DOUBLE LAMP FLUORESCENT

LUMINAIRE (2x36W)

WIRING/CABLING RECESSED IN WALL,

SLAB

SINGLE (1way) SWITCH FLUSH MOUNTED

TWO-WAY FLUSH MOUNTED SWITCH

SINGLE SOCKET OUTLET 16/10A, 250V

FLUSH MOUNTED DOUBLE SOCKET

OUTLET 16/10A, 250V

FLUSH MOUNTED SINGLE SOCKET

OUTLET 16/10A, 250V

FLUSH MOUNTED SINGLE SOCKET OUTLET

WATER PROOF 16/10A, 250V

MANHOLE

FLUSH MOUNTED TELEPHONE/DATA OUTLET

SYMBOL

INDICATES TYPE NUMBER

X INDICATES RATING

SYMBOLS LEGEND

FLUSH MOUNTED TELEPHONE OUTLET

WALL MOUNTED SINGLE LAMP

FLUORESCENT LUMINAIRE (1x36W)

DOUBLE POLE FLUSH MOUNTED SWITCH

LPP-*

FLUSH MOUNTED - LIGHTING & POWER

PANEL, * INDICATES BLOCK NAME

TEL TERMINAL BOX

CEILING MOUNTED LUMINAIRE

CIRUIT HOME RUN WITH FEEDER PANEL

AND CIRCUIT NUMBER

x

**A

T

T/D

WATERPROOF FLUSH MOUNTED SOCKET

16/10A, 250V WITH WATER PROOF SWITCH

TEL CABLE IN PVC DUCT

TEL/DATA CABLE IN PVC DUCT

INDICATES SELF CONTAINED , WITH 3HRS

STANDBY BATTERY PACK

EXIT

8W, EXIT SIGN, SELF CONTAINED, WITH

3HRS STAND-BY BATTERY PACK & WITH

DIRECTION SIGN

EXTERIOR STAND ALONE SOLAR

POWERED FLOOD LIGHTING

EXTERIOR STAND ALONE SOLAR POWERED

FLOOD LIGHTING WITH 3.5m POLE

LABEL SIGNAGE ABOVE SWITCH OF

EMERGENCY LIGHT PER WALL SIGNAGE

DETAIL ON AR-085

NOTE

1. LIGHTING

1.1 INSTALLATION METHOD-INCONCRETE, ABOVE CEILING, IN SLAB

AS INDICATED ON THE DRAWINGS AND SPECIFICATIONS

1.2 LIGHT FITTING TO BE SURFACE MOUNTED WHERE FALSE CEILING

IS PROVIDED AND ON BEAMS OTHERWISE THEY ARE FLUSH MOUNTED.

1.3 PRIOR TO COMMENCEMENT OF WORK VERIFY THE FOLLOWING:-

- LOAD BALANCE ON PHASES,

- IP- CLASS IN DIFFERENT LOCATIONS.

1.4 PROVIDE ACCESS TO ALL JUNCTION BOXES AND APPLIANCES

INSTALLED ABOVE SUSPENDED CEILING.

1.5 CONDUITS SUPPORTS ARE TO BE USED FOR INSTALLATIONS

ABOVE CEILING AND WHENEVER INSTALLATION IS TO BE DONE ON

WALL OR BEAM SURFACES, CONDUITS SHOULD BE BURIED.

1.6 LIGHT SWITCHES SHALL BE INSTALLED AT 1200MM FROM THE

FINISHED FLOOR LEVEL AND 150MM FROM DOOR EDGE, ON

OPENING SIDE OF DOOR

2. POWER

2.1 INTERIOR ELECTRICAL/TELE/DATA INSTALLATION SHALL BE ABOVE

CEILING. NO ELECTRICAL INSTALLATION SHALL BE DONE IN FLOORING.

2.2 INSTALLATIONS IN BATH ROOM, KITCHEN, WET AREA AND

OUTDOOR ARE WEATHERPROOF.

2.3 ALL OUTLET INSTALLATION SHALL BE DONE WITH EARTH FAULT

CIRCUIT INTERRUPTER BREAKERS

2.4 CONFIRM TYPE AND GET APPROVAL TO ALL UNSPECIFIED

POWER APPLIANCES.

2.5 INSTALL CONDUITS FOR OUTLETS IN SLAB SCREED WHERE

REQUIRED.

2.6 FOLLOW TN-S SYSTEM (THREE PHASE + NEUTRAL + EARTH)

IN ALL INSTALLATIONS.

2.7 PRIOR TO COMMENCEMENT OF WORK VERIFY THE FOLLOWING:-

- LOAD BALANCE ON PHASES,

- IP- CLASS IN DIFFERENT LOCATIONS.

2.8 PROTECT ALL CABLES FROM MECHANICAL DAMAGE

2.9 OUTLETS SHALL BE INSTALLED AT 450MM FROM THE FINISHED

FLOOR LEVEL

3. AUXILIARY SYSTEMS

3.1 ALL SYSTEM WIRING AND CABLING TO BE DONE

ACCORDING TO SYSTEM SUPPLIER AND ACCORDING TO LOCAL

AUTHORITY REQUIREMENTS.

3.2 COMPLETE APPROVED OPERATIONAL SYSTEM TO BE PROVIDED BY

A SINGLE MANUFACTURER.

3.3 ADJUST FINAL LOCATION AND INSTALLATION OF ALL AUXILIARY

SYSTEMS ACCORDING TO SUPPLIER RECOMMENDATION.

4. GENERAL NOTES

4.1 ELECTRICAL POWER DISTRIBUTION SYSTEM, OUTSIDE THE BLOCKS

INCLUDING LINES SUPPLYING POWER FROM ONE BLOCK TO

ANOTHER SHALL BE INSTALLED UNDERGROUND. WARNING TAPE

SHALL BE INSTALLED ABOVE.

4.2 THE PV PANEL MODULE OF THE EXTERIOR STANDALONE SOLAR

POWERED FLOOD LIGHT UNIT SHALL BE INSTALLED FACING SOUTH AT

AN ANGLE EQUAL TO THE SITE LATITUDE, FOR MAXIMUM EFFICIENCY

OR OPTIMUM POWER OUTPUT OVER A YEAR.

4.3 PLASTIC EXTRUDED WIRE TRAY SIZE 25 X 25MM SHOULD BE

INSTALLED IN EACH ELECTRIC DISTRIBUTION BOARD.

4.4 ELECTRICAL CABLE SHALL BE INSTALLED IN SUITABLE CONDUIT

AND MINIMUM OF 600MM FROM LIQUID SERVICE LINES(PARALLEL)

OR 100MM ABOVE LIQUID LINES(CROSSOVER).

LIGHTNING PROTECTION NOTE

1. THE PROTECTION ZONE SHALL BE THE ELEVATED WATER TANKS,

INSTALL OTHER AIR TERMINATIONS IF ONE AIR TERMINATION CAN

NOT COVER THE WATER TANKS

2. IF PORTIONS OF A STRUCTURE OR COMPOUND VARY

CONSIDERABLY IN HEIGHT, ANY NECESSARY AIR TERMINATION OR AIR

TERMINATION NETWORK FOR THE LOWER PORTIONS SHALL BE

JOINED TO THE DOWN CONDUCTORS OF THE TALLER PORTIONS IN

ADDITION TO BEING JOINED TO THEIR OWN DOWN CONDUCTOR

3. THE AIR TERMINAL UNIT SHALL POSSES EXCEPTIONAL ELECTRICAL

CHARACTERISTICS, NO ANTENNA AND BEACON INTERFERENCE,

100KPH SURVIVAL WIND SPEED AND REPLACEABLE DISSIPATING TIPS

4. VERTICAL AIR TERMINAL SHALL BE MADE OF SOLID 16MM DIAM

COPPER ROD, AND THE INSTALLATION HEIGHT SHALL ENABLE THE

TERMINAL TO PROTECT THE NEARBY OBJECTS

5. AIR TERMINAL STAND IS TO BE FIXED BY 4X10MM BOLT, USE BOLTED

CLAMP MADE OF COPPER TO CONNECT AIR TERMINAL UNIT WITH

DOWN CONDUCTOR

6. PROVIDE AT LEAST TWO DOWN CONDUCTORS FOR ANY KIND OF

BUILDING STRUCTURE.

7. DOWN CONDUCTORS SHALL BE 50 MM SQ ROD/STRIP. THE

CONDUCTORS SHOULD TERMINATE AT EARTH RODS, THE

TERMINATION SHALL BE MADE BY CLAMPING AND CLAMPS SHALL BE

SECURED WITH AT LEAST TWO BOLTS AND SHALL MAKE CONTACT

WITH THE EARTH ROD FOR AT LEAST 380MM SQ.

8. PROTECT THE DOWN CONDUCTORS FROM MECHANICAL DAMAGE

2 METERS ABOVE GRADE LEVEL

9. SHARP BEND - NO BEND OF A CONDUCTOR SHALL FORM AN

INCLUDED ANGLE OF LESS THAN 90 DEGREE OR HAVE A RADIUS OF

BEND LESS THAN 203MM

10. ANY METAL IN OR FORMING PART OF THE STRUCTURE IN

CONTACT WITH THE EARTH SHALL BE BONDED TO THE AIR

TERMINATION NETWORK OR TO DOWN CONDUCTOR AND EARTHING

CONNECTION SHALL BE MADE TO EACH STEEL COLUMN AROUND THE

PERIMETER

11. INSTALL DIAM 16MM L 3000MM COPPER ROD AT 600MM FROM

THE STRUCTURE

12. EARTHING RESISTANCE OF THE WHOLE EARTH TERMINATION

NETWORK SHOULD NOT BE GREATER THAN 5 OHMS, IF IT IS GREATER

THAN 5 OHMS INSTALL ANOTHER EARTHING ROD WITHIN A DISTANCE

NOT GREATER THAN THE LENGTH OF THE ROD

13. IF ELECTRIC, TELEPHONE OR OTHER SYSTEMS ARE EARTHED TO A

COMMON TERMINAL, ONE CONNECTION FROM THE LIGHTNING

PROTECTION SYSTEM TO THE TERMINAL IS REQUIRED.

14. ALL MATERIALS AND ACCESSORIES SHOULD BE RUST/CORROSION

PROOF, ALL COMPONENTS LOCATED WITH IN 610MM OF CHIMNEY

GASES OR OTHER SIMILAR CORROSIVE GASES SHALL BE PROTECTED

BY A CONTINUOUS HOT-DIPPED COATING OF LEAD

EL-000

S Y M

B O

LS

N

O

TE

S A

N D

A B B R

EV

IA

TI

O N

S

SYMBOLS, NOTES AND ABBREVIATIONS, SCALE NTS

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

IG

N

S U

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

Power Utility Company Transformer

15/0.4kV, 50kVA, 4Wire+E, 0.8Cos , 50Hz

Y

D

N-PE LINK

E16x2400mm Earth Rod

16x2400mm Earth Rod

MSB

(1x16) sq mm Earth Conductor

(1x16) sq mm Earth Conductor by others

(by the Power Utility Company)

REFERENCE DRAWINGS:

- EL-000 Symbols, Notes and Abbreviations

- EL-005 Distribution Board Schedules

- C-005 Site Electrical Layout

2. If earthing resistance is greater than 5 Ohm additional electrode shall be buried spaced not less than the length of the electrode.

1. Earthing resistance shall not be greater than 5 Ohm.

NOTE

Earthing conductor 1x16 sq mm to MSB

Earthing Rod copper clad steel Diameter 16 mm, length 2400 mm

Ground level

Manhole 700x700x700 mm

( MAIN SWITCH BOARD )

Pmax.= 39.66 kVA Ptot.= 56.65 kVA

3x80A, 20kA(4x16+1x16) sq mm

Power Utility Company Transformer

15/0.4kV, 50kVA, 4Wire+E, 0.8Cos , 50Hz kWatt- Hour-Meter

0A m p, P ha se

, 4 W

E, 0.

Po w er F ac to r, H z 6

No

LPP-A

Distribution Panel A(mm )2

1x25

I(A)

03.55

Load (kVA)

2x4+1x4

Spare Spare

LPP-B 3x50 19.054x10+1x10 LPP-C 3x25 07.904x4+1x4 LPP-D 3x40 12.004x6+1x6 LPP-E 3x25 08.804x6+1x6 LPP-F 1x20 02.35

Spare Spare Pump Control Panel

2x4+1x4

Spare

3x16 03.004x2.5+1x2.5 3x40 3x25 3x25 by others

(by the Power Utility Company)

EL-001

EL

EC

TR

IC

A L

FI

TT

IN

G

S C

H

ED

U

LE

S

ELECTRICAL FITTING SCHEDULES, SCALE NTS

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

DESCRIPTION

LIGHTING FITTING SCHEDULE

NUMBER

MOUNTINGNO

WATTAGE

LAMP

IP RATING

TYPE

2 1 36 65FluorescentCeiling

3 Ceiling 2

Wall

1 13 65

5.1

RZB 25102.962 with 1xTC-D 18W Compact Fluorescent Lamp1 18 43Compact Fluorescent

1 Ceiling Fluorescent Fitting Philips TMS 022/136 IC with 1xTL-D 36 W Lamp 1 36 20Fluorescent

Fluorescent Fitting Philips TMW 065/136 IC with 1xTL-D 36 W Lamp

36 65Fluorescent

Ceiling 2 36 20Fluorescent Fluorescent Fitting Philips TMS 022/236 IC with 2xTL-D 36 W Lamps

Ceiling

Compact Fluorescent RZB 20146.922 with 1xTC-D 13W Compact Fluorescent Lamp, Supplied by Battery

Fluorescent Fitting Philips TMW 065/236 IC with 2xTL-D 36 W Lamps

Wall 1 13 44Compact Fluorescent RZB 20146.922 with 1xTC-D 13W Compact Fluorescent Lamp

7 Wall 1 08 Fluorescent Exit Light, self contained, 3hrs stand-by battery, Type MODUS Star 8FP3 with 1x8W Linear Fluorescent Lamp T5 + Direction (Pictograms)

6.1 Wall 1 13 65Compact Fluorescent RZB 20146.922 with 1xTC-D 13W Compact Fluorescent Lamp, Supplied by Battery

EL-001A

EL

EC

TR

IC

A L

FI

TT

IN

G

S C

H

ED

U

LE

S

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

ELECTRICAL FITTING SCHEDULES, SCALE NTS

BLOCK-A,

WAITING & REGISTRATION

BLOCK-C, ADMINISTRATION & PHARMACY

BLOCK-E, IPD (WARD)BLOCK-D, DELIVERY

BLOCK-B, OPD

BLOCK-G,

PIT LATRINE

BLOCK-I,

LAUNDRY

BLOCK-F

INFECTIOUS

DISEASE

LPP-E

LPP-C

LPP-B

LPP-D

3 3

4 4

5 4

EX

IT

EX

IT

EX

IT

EX

IT

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

Lighting Line under Floor/Ground 3x2.5mm2 cable in 32mm diameter pvc

4 3

7 7 7 7

Reference Drawings:

- EL-000 Symbols, Notes and Abbreviations

- EL-001 Electrical Fitting Schedules

- EL-005 Distribution Board Schedules

- C-005 Site Electrical Layout

1. Socket Outlet, Telephone Outlet, TV Outlet shall be at 450mm from the finished floor level.

2. Light switches shall be at 1200mm from the finished floor level and 150mm from the door edge.

3. Use Trench and Electrical Manholes in C-005 as

Required

4. Connections of Battery, Inverter and Load shall be per

Manufacturer Recommendation

Installation Notes

Roof Ceiling

LUMINAIRE UNDER CEILING

CONCEALED WIRING TYPICAL

INSTALLATION DETAIL

LUMINAIRE UNDER CEILING

EXPOSED WIRING TYPICAL

INSTALLATION DETAIL

2 3

Wiring box, connection and outlet to luminaire

Conduit, above ceiling

Luminaire, surface mounting

Roof truss

1 3

Cable, clipped to the ceiling, from panel, switch, or from other luminaire

Wiring box, connection able, clipped to the ceiling to / from luminaire only

Luminaire, surface mounting, with through wiring to next luminaire

LPP-F

MALE WARD

JANITOR

ROOM

NURSE

STATION

FEMALE &

PEDIATRIC

WARD

COVERED

WALK WAY

MEDICAL SUPPLIES

STORE

PHARMACY

STORE

ADMIN. 02

HMIS

ADMIN. 01

COVERED WALK WAY

A B C D

S T

CORRIDOR

BLOCK-J

IRONING

/CLEAN LINEN

STORE

U

K L M N

Z6 Z7 Z8

LABORATORY

EXAM 01

FAMILY PLANNING

EMERGENCY

VCT

(HIV counseling)

VACCINATION/

TREATMENT

E F G H

EXAM 02

ANC/PMTCT

UNDER FIVE CLINIC

ART

PNC

I J

TRIAGE ROOM

REGISTRATION

CASHIER

NURSE

STATION

EN

TR

Y F

O R I N

FE

C

TI

O

U S D

IS

EA

S E

Z3 Z4

SHOWER(GENTS)

SHOWER(LADIES)

COVERED

WALK WAY

CORRIDORCORRIDOR

CORRIDOR

±0.00

BEAM LINE ABOVE

NURSE PREP.

ELEVATED

WATER TANK

X

PIT(GENTS)

PIT

PIT FOR

DISABLED

PIT

PIT FOR

DISABLED

PIT(LADIES)

PIT

PIT FOR

DISABLED

PIT(GENTS

AND LADIES)

Y Y' Y''

V

INFECTIOUS

WAITING AREA

INFECTIOUS

DISEASE

STORE

W

P Q R

SCRUB STERILIZAT.

DELIVERY

RECOVERY BEDS

MINOR OPERATION

ROOM

LABOUR

PREPARATION/

NURSE STATION

SLUICE

RM.

STORE

O

TOILET

CORRIDOR

CHANGING

J'K'

O' U'

WALK WAY

SAMPLE

EXTRACTION

WC

10'

8'

14'

12'

2 2 2 2 2 2

LIGHT FIXTURE TO BE

INSTALLED ABOVE LPP-F

WATER PROOF

SWITCH

WATER PROOF

SWITCH

4 44

2 2

4 4

WAITING AREA

5.1

5.1

5.1 5.1

5.1

5.1 5.1

5.1

6.1

6.1

6.1

6.1

WATER PROOF

SWITCH

WATER PROOF

SWITCH

BATTERY AND

INVERTER RACK

LPP-BATTERY

POWER SUPPLY

FROM MSB

UNLESS OTHERWISE NOTED, ALL

DIMENSIONS SHOWN ARE IN CENTIMETERS.

EL-002

EL

EC

TR

IC

A L

FL

O

O R P

LA

N

L

IG

H

TI

N

G L

A Y O

U T

ELECTRICAL FLOOR PLAN - LIGHTING LAYOUT SCALE 1:125

1:150

5 0 5 10 15

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

LPP-E

LPP-C LPP-B

LPP-F

LPP-D

LPP-A

6 117 1312

Reference Drawings:

- EL-000 Symbols, Notes and Abbreviations

- EL-001 Electrical Fitting Schedules

- EL-005 Distribution Board Schedules

- C-005 Site Electrical Layout

1. Socket Outlet, Telephone Outlet, TV Outlet shall be at 450mm from the finished floor level.

2. Light switches shall be at 1200mm from the finished floor level and 150mm from the door edge.

Positions of Electrical Outlets

BLOCK-A,

WAITING & REGISTRATION

BLOCK-C, ADMINISTRATION & PHARMACY

BLOCK-E, IPD (WARD)

BLOCK-D, DELIVERY

BLOCK-B, OPD

BLOCK-G,

PIT LATRINE

BLOCK-I,

LAUNDRY

BLOCK-F

INFECTIOUS

DISEASE

MALE WARD

JANITOR

ROOM

NURSE

STATION

FEMALE & PEDIATRIC

WARD

COVERED

WALK WAY

MEDICAL SUPPLIES

STORE PHARMACY

STORE

ADMIN. 02

WAITING AREA

HMIS

ADMIN. 01

COVERED WALK WAY

A B C D

S T

CORRIDOR

BLOCK-J

IRONING

/CLEAN LINEN

STORE

U

K L M N

Z6 Z7 Z8

LABORATORY

EXAM 01

FAMILY PLANNING

EMERGENCY

VCT

(HIV counseling)

VACCINATION/

TREATMENT

E F G H

EXAM 02

ANC/PMTCT

UNDER FIVE CLINIC

ART

PNC

I J

TRIAGE ROOM

REGISTRATION

CASHIER

NURSE

STATION

EN

TR

Y F

O R I N

FE

C

TI

O

U S D

IS

EA

S E

Z3 Z4

SHOWER(GENTS)

SHOWER

(LADIES)

COVERED

WALK WAY

CORRIDOR

CORRIDOR

CORRIDOR

±0.00

BEAM LINE ABOVE

NURSE PREP.

X

PIT(GENTS)

PIT

PIT FOR

DISABLED

PIT

PIT FOR

DISABLED

PIT(LADIES)

PIT

PIT FOR

DISABLED

PIT(GENTS

AND LADIES)

Y Y' Y''

V

INFECTIOUS

WAITING AREA

INFECTIOUS

DISEASE

STORE

W

P Q R

SCRUB

STERILIZAT.

DELIVERY

RECOVERY BEDS

MINOR OPERATION

ROOM

LABOUR PREPARATION/

NURSE STATION

SLUICE

RM.

STORE

O

TOILET

CORRIDOR

CHANGING

J'K'

O' U'

WALK WAY

SAMPLE

EXTRACTION

WC

10'

8'

14'

12'

LIGHT FIXTURE TO BE

INSTALLED ABOVE LPP-F

WATER PROOF

SWITCH

WATER PROOF

SWITCH

ELEVATED

WATER TANK

DOUBLE SOCKETS WITH COVER,

INSTALL 20CM ABOVE COUNTER

1.8M ABOVE FFL

1.8M ABOVE FFL

1.8M ABOVE FFL

1.8M ABOVE FFL

UNLESS OTHERWISE NOTED, ALL

DIMENSIONS SHOWN ARE IN CENTIMETERS.

EL-003

EL

EC

TR

IC

A L

FL

O

O R P

LA

N

S

O C

K

ET

L A

Y O

U T

ELECTRICAL FLOOR PLAN - SOCKET LAYOUT SCALE 1:125

1:150

5 0 5 10 15

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

Tel Intake PVC Pipe Ø 50mm from Tel Utility Company System (Incoming Direction Indicative)

Main Tel Terminal Box

T/D T/D

T/D

T/D T/D

T/D T/D

T/D

T/D T/D

T/D

T/DT/D

T/D T/D

T/D

T/D

T/D

T/D

T/D

T/D

Reference Drawings:

- EL-000 Symbols, Notes and Abbreviations

- C-005 Site Electrical Layout

1. Socket Outlet, Telephone Outlet, TV Outlet shall be at 450mm from the finished floor level.

2. Tele/Data cable shall be installed in suitable conduit at min 30cm from electric lines(parallel) or 20cm above electric lines(crossing).

3. Install CAT-6E outdoor full copper Tele/Data cable.

4. Use the manholes in C-005 as required and per note 2 above.

Construction Notes:

Telephone/Data line under Floor/Ground PVC pipe diam 32mm Telephone/Data line under Floor/Ground

PVC pipe diam 32mm

Telephone/Data line underground PVC pipe diam 50mm each

Telephone/Data line under Floor/Ground PVC pipe diam 32mm

BLOCK-A,

WAITING & REGISTRATION

BLOCK-C, ADMINISTRATION & PHARMACY

BLOCK-E, IPD (WARD)

BLOCK-D, DELIVERY

BLOCK-B, OPD

BLOCK-G,

PIT LATRINE

BLOCK-I,

LAUNDRY

BLOCK-F

INFECTIOUS

DISEASE

MALE WARD

JANITOR

ROOM

NURSE

STATION

FEMALE & PEDIATRIC

WARD

COVERED

WALK WAY

MEDICAL SUPPLIES

STORE

PHARMACY

STORE

ADMIN. 02

WAITING AREA

HMIS

ADMIN. 01

COVERED WALK WAY

A B C D

S T

CORRIDOR

BLOCK-J

IRONING

/CLEAN LINEN

STORE

U

K L M N

Z6 Z7 Z8

LABORATORY

EXAM 01

FAMILY PLANNING

EMERGENCY

VCT

(HIV counseling)

VACCINATION/

TREATMENT

E F G H

EXAM 02

ANC/PMTCT

UNDER FIVE CLINICART

PNC

I J

TRIAGE ROOM

REGISTRATION

CASHIER

NURSE

STATION

EN

TR

Y F

O R I N

FE

C

TI

O

U S D

IS

EA

S E

Z3 Z4

SHOWER(GENTS)

SHOWER(LADIES)

COVERED

WALK WAY

CORRIDORCORRIDOR

CORRIDOR

±0.00

BEAM LINE ABOVE

NURSE PREP.

X

PIT(GENTS)

PIT

PIT FOR

DISABLED

PIT

PIT FOR

DISABLED

PIT(LADIES)

PIT

PIT FOR

DISABLED

PIT(GENTS

AND LADIES)

Y Y' Y''

V

INFECTIOUS

WAITING AREA

INFECTIOUS

DISEASE

STORE

W

P Q R

SCRUB STERILIZAT.

DELIVERY

RECOVERY BEDS

MINOR OPERATION

ROOM

LABOUR

PREPARATION/

NURSE STATION

SLUICE

RM.

STORE

O

TOILET

CORRIDOR

CHANGING

J'K'

O' U'

WALK WAY

SAMPLE

EXTRACTION

WC

10'

8'

14'

12'

LIGHT FIXTURE TO BE

INSTALLED ABOVE LPP-F

WATER PROOF

SWITCH

WATER PROOF

SWITCH

P1 P2

P

P

Manhole 600x600x700mm

UNLESS OTHERWISE NOTED, ALL

DIMENSIONS SHOWN ARE IN CENTIMETERS.

EL-004

EL

EC

TR

IC

A L

FL

O

O R P

LA

N

T

EL

D

A

TA

L A

Y O

U T

ELECTRICAL FLOOR PLAN - TEL/DATA LAYOUT SCALE 1:125

1:150

5 0 5 10 15

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

0900.00

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0900.00

SUB TOTAL

kVA CONNECTED

2300.00

LINE AMPERE

kVA DEMAND

DIVERSITY

07.90

12.00 07.90 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-C

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

25 Ampere, 3 Phase, ACB

(4x4+1x4) sq mm

3100.00 2500.00

103x2.5 1Lighting

C103x2.5 1Lighting C161 C161 C161 C161

1000.00 1200.00

C161

Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet*

Socket Outlet* 3x2.5 3x2.5 3x2.5 3x2.5 3x2.5

Patch Panel* Spare Spare

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

SPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

0250.00

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0700.00

SUB TOTAL

kVA CONNECTED

LINE AMPERE

kVA DEMAND

DIVERSITY

03.55

16.14 03.55 01.00

CIRCUIT LOAD PER PHASE

2 Wire+E, 50 Hz 220 Volt, 1 Phase, LPP-A

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE CIRCUIT

NUMBER DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

25 Ampere, 1 Phase, ACB

(2x4+1x4) sq mm

3550.00

103x2.5 1Lighting

1000.00C163x2.5 1

Patch Panel* Spare

Lighting2

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

0900.00

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0950.00

SUB TOTAL

kVA CONNECTED

6550.00

LINE AMPERE

kVA DEMAND

DIVERSITY

19.05

28.94 19.05 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-B

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

50 Ampere, 3 Phase, ACB

(4x10+1x10) sq mm

6400.006100.00

103x2.5 1Lighting

C163x2.5 1 C161 C161 C161

4 0800.00

3x2.5 3x2.5 3x2.5

Socket Outlet*

C161 C161

3x2.5 3x2.5

1400.00C163x2.5 1

Spare

C103x2.5 1Lighting C103x2.5 1Lighting C103x2.5 1Lighting

C1613x2.5 C1613x2.5 C1613x2.5 C1613x2.5 C1613x2.5

1200.00 1000.00

1200.00 1200.00

1200.00

C161 C161

C161 C

C161 C161 C161

Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet*

* : with 300mA Earth Fault Interrupter

* : with 300mA Earth Fault Interrupter

Patch Panel 2*20 Patch Panel 1*19

3x2.5 Socket Outlet*

C C161 C161

Water Heater* 3x2.5 C

C Water Heater*

3x2.5

1000.00 1200.00

1200.00

(mm²)

(mm²)

(mm²)

0300.00

1000.00 1200.00

1200.00

1000.00

0400.00 0800.00

1200.00 1000.00

1200.00 1200.00

0200.00 0200.003x2.5

Spare22 Spare23

C161 C161

Spare7 C161

0200.003x2.5

11 Spare C161

3x2.5 0200.00

Socket Outlet* Socket Outlet*

* : with 300mA Earth Fault Interrupter

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

1050.00

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0250.00

SUB TOTAL

kVA CONNECTED

4250.00

LINE AMPERE

kVA DEMAND

DIVERSITY

12.00

18.23 12.00 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-D

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

40 Ampere, 3 Phase, ACB

(4x6+1x6) sq mm

3350.00 4400.00

103x2.5 1Lighting

1200.00C103x2.5 1 C

C

C

1000.00 0800.00

Water Heater*

3x2.5 3x2.5 3x2.5

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

0300.00

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0700.00

SUB TOTAL

kVA CONNECTED

2900.00

LINE AMPERE

kVA DEMAND

DIVERSITY

08.80

13.37 08.80 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-E

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

25 Ampere, 3 Phase, ACB

(4x6+1x6) sq mm

2900.003000.00

103x2.5 1Lighting

C163x2.5 1 C161 C161

1000.00 3x2.5 3x2.5

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

SPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

0400.00

(VOLT-AMPERE)

C

C

1RATING

BREAKER

TYPE

0550.00

SUB TOTAL

kVA CONNECTED

LINE AMPERE

kVA DEMAND

DIVERSITY

02.35

10.68 02.35 01.00

CIRCUIT LOAD PER PHASE

2 Wire+E, 50 Hz 220 Volt, 1 Phase, LPP-F

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE CIRCUIT

NUMBER DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

20 Ampere, 1 Phase, ACB

(2x2.5+1x2.5) sq mm

2350.00

103x2.5 1Lighting

0800.00 C163x2.5 1

Spare

Socket Outlet*

Spare

1613x2.5

3x2.5

161Exit Signage 3x2.5

C C C

1000.00 1000.00

1000.00

Spare

C161 Socket Outlet (Iron.)*

3x2.5

C103x2.5 1Lighting

Lighting

1200.00

Socket Outlet*

C103x2.5 1Lighting to PIT LAT

0600.00

161 C

161 C 161 C

C161 C161 C161

C161

1000.00

Socket Outlet* Socket Outlet* Socket Outlet* Socket Outlet*

Socket Outlet* Socket Outlet* Socket Outlet*

* : with 300mA Earth Fault Interrupter

* : with 300mA Earth Fault Interrupter

* : with 300mA Earth Fault Interrupter

Water Heater* 3x2.5

Spare

161 C

1200.00

(mm²)

(mm²)

(mm²)

161 C Water Heater* 3x2.5 1200.00

161 C

Socket Outlet* 3x2.55 1000.00

3x2.5

C161

Exit Signage

Water Heater* 3x2.5 1200.00

0100.00

Water Heater* Water Heater*

3x2.5 3x2.5

0700.00 0100.00

1400.00

1200.00 1200.00

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

100A, 25 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

(VOLT-AMPERE)

C

1RATING

BREAKER

TYPE

SUB TOTAL

kVA CONNECTED

19750.00

LINE AMPERE

kVA DEMAND

DIVERSITY

56.650

60.240 39.655 00.700

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, MSB

SERVICE

VOLTAGE :

PANEL NO :

SIZE OF

WIRE

CIRCUIT

NUMBER

DESCRIPTION

Power Supply System

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

80 Ampere, 3 Phase, ACB

(4x16+1x16) sq mm

253x4 1LPP-A

Pump Control Panel Inverter/Battery Pack Spare

3550.00 C505x10 3LPP-B 6550.00 6400.006100.00 C255x4 3LPP-C 2300.00 3100.00 2500.00 C405x6 3LPP-D 4250.003350.00 4400.00 C255x4 3LPP-E 3000.00 2900.002900.00

LPP-F 2350.00C203x2.5 1

17350.00 19550.00

Spare

C165x2.5 3 1000.001000.00 1000.00

Reference Drawings:

- EL-000 Symbols, Notes and Abbreviations

- EL-001 Electrical Fitting Schedules

- C-005 Site Electrical Layout

(mm²)

C C C

TOTAL POWER DEMAND - 45.32KW

11 Spare 253 C

1000.00

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

SPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

(VOLT-AMPERE)

C

1RATING

BREAKER

TYPE

0600.00

SUB TOTAL

kVA CONNECTED

LINE AMPERE

kVA DEMAND

DIVERSITY

00.65

02.95 00.65 01.00

CIRCUIT LOAD PER PHASE

2 Wire+E, 50 Hz 220 Volt, 1 Phase, LPP- BATTERY

SERVICE

VOLTAGE :

PANEL NO :

SIZE OF

WIRE CIRCUIT

NUMBER DESCRIPTION

MSB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

16 Ampere, 1 Phase, ACB

(3x2.5) sq mm

0650.00

103x1.5 1Room & Compound

0050.00C103x1.5 1 Lighting

3 C103x2.5 1

(mm²)

Entrance Pole Light Spare

EL-005

EL

EC

TR

IC

A L

D

IS

TR

IB

U

TI

O N

B O

A R D

S C

H

ED

U

LE

S

ELECTRICAL DISTRIBUTION BOARD SCHEDULES, SCALE NTS

BE

T

BE

T

TE

TR

A T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

F

IN

A L

D

ES

B M

IT

TA

L

TTD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

AP

R

SY

MB

100%

FINAL

DESIGN

SUBMITTAL

FI

NA

L D

ES

IG

N

DR

AW

IN

GS

File details come from the government source that posted it. Updated .