Attachment_J.5_-_Group_-4_Unpriced_BOQ_Debat_Health_Center.xls

XLS spreadsheet 388 KB Posted

Attached to
National Blood Transfusion Center and 17 Health Centers Construction Project
Solicitation number
SOL-663-16-000001
Issued by

About this file

Attachment J.5 - Group -4 Unpriced BOQ Debat Health Center

View the file

Other files

File Type Posted
Amendment_000002_(SF_30_with_Q A)_-_SOL-663-16-000001.pdf PDF
Attachment_J.15_-_AID1420-17_Contractor_Employee_Biographical_Data_Sheet.doc DOC document
Attachment_J.14_-_Geo-technical_Report.pdf PDF
Amendment__000001_full_package.pdf PDF
Attachment_J.5_-_Group_-3_Unpriced_BOQ_Girana_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_2.2_-GERBICHO_SITE_DEVELOPMENT_DWGS.pdf PDF
SOL-663-16-000001.pdf PDF
Attachment_J.6_-_NBTS_-_Drawings_Volume_2_of_2.pdf PDF
Attachment_J.4_-_Health_Centers_-_Specifications_(2015-10-09).pdf PDF
Attachment_J.5_-_Group_-7_Unpriced_BOQ_Gulem_Dejen_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_4.1_-WELELA_BAHER_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.11_-_Past_Performance_Information.docx DOCX document
Attachment_J.1_-_Pricing_Tables.xlsx XLSX spreadsheet
Attachment_J.5_-_Group_-5_Unpriced_BOQ_Lideta_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-6_Unpriced_BOQ_Gult_Health_Center.xls XLS spreadsheet
Attachment_J.8_-_NBTS_-_Quantity_Estimates.pdf PDF
Attachment_J.3_-_Site_5.2_-KUNI_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_3.2_-GIRANA_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_10_-_VAT_Reimbursement_Processes.pdf PDF
Attachment_J.2_-_HC_Prototype_Drawings_-_3_of_6_-_Architectural.pdf PDF
Attachment_J.5_-_Group_-3_Unpriced_BOQ_Gelsha_Health_Center.xls XLS spreadsheet
Attachment_J.7_-_NBTS_-_Specifications.pdf PDF
Attachment_J.5_-_Group_-5_Unpriced_BOQ_Kuni_Health_Center.xls XLS spreadsheet
Attachment_J.12_-_Contractor_Performance_Report_-_Short_Form.pdf PDF
Attachment_J.5_-_Group_-1_Unpriced_BOQ_Lemi_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Progress_Summary.pdf PDF
Attachment_J.3_-_Site_3.3_-GELSHA_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.2_-_HC_Prototype_Drawings_-_4_of_6_-_Structural.pdf PDF
Attachment_J.2_-_HC_Prototype_Drawings_-_6_of_6_-_Electrical.pdf PDF
Attachment_J.5_-_Group_-2_Unpriced_BOQ_Gerbicho_Health_Center.xls XLS spreadsheet
Attachment_J.8_-_NBTS_-_Product_Samples.pdf PDF
Attachment_J.5_-_Group_-2_Unpriced_BOQ_Finchawa_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_7.1_-KACHANA_GUDIE_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.5_-_Group_-5_Unpriced_BOQ_Agumamit_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-7_Unpriced_BOQ_Kechena_Gudie_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-2_Unpriced_BOQ_Haro_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-6_Unpriced_BOQ_Maksegnit_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-4_Unpriced_BOQ_Welela_Bahir_Health_Center.xls XLS spreadsheet
Attachment_J.9_-_Umbrella_EMMP_for_EHIP.pdf PDF
Attachment_J.5_-_Group_-4_Unpriced_BOQ_Addis_Bete_Chiristian_Health_Center.xls XLS spreadsheet
Attachment_J.5_-_Group_-3_Unpriced_BOQ_Kulmesk_Health_Center.xls XLS spreadsheet
Attachment_J.3_-_Site_5.3_-GULEM_DEJEN_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_2.3_-HARO_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.6_-_NBTS_-_Drawings_Volume_1_of_2.pdf PDF
Attachment_J.3_-_Site_4.2_-ADDIS_BET_CHRISTIAN_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_2.1_-FINCHAWA_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.5_-_Site_Progress_Tables_-_Available_Materials.pdf PDF
Attachment_J.3_-_Site_6.2_-MAKSEGNIT_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_6.1_-GULT_SITE_DEVELOPMENT_DWGS.pdf PDF
Attachment_J.3_-_Site_1.2_-LEMI_SITE_DEVELOPMENT_DWGS.pdf PDF
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cover

Ethiopia Health Infrastructure Project ( EHIP)
Health Center Design-Site Adaptation
Bill of Quantities
Debat,Site 222
Prepared by USAID/Ethiopia
August 20, 2015
Line items, quantities, and completion percentages serve only as estimates for USAID's cost estimates. This information is not binding in any way and is provided for informational purposes only. The Contractor is responsible for determining materials, quantities, and completion percentages based on the drawings, specifications, and site conditions.

Sum

EHIPDebat,Site 222
Date:20-Aug-15
DescriptionTotal
USD
1. BUILDING CONSTRUCTION
Block-AWAITING AND REGISTRATION- 0
Block-BOPD BLOCK- 0
Block-CADMINISTRATION AND PHARMACY- 0
Block-DDELIVERY- 0
Block-EIPD WARD- 0
Block-FINFECTIOUS DISEASES- 0
Block-GPIT LATRINE- 0
Block-HGUARD HOUSE (Deleted)- 0
Block-ILAUNDRY- 0
Block-JCOVERED WALK WAY- 0
Block-KPUMP HOUSE (Deleted)
SUB TOTAL Section 1- 0
2. SITE WORKS (Site Utilities and Auxiliary Facilities)
2A GRADING, DRAINAGE, LANDSCAPING AND PAVING
1Excavation and Earthwork- 0
2Retaining Walls- 0
3Drainage Structures- 0
4Erosion Control- 0
5Site Paving- 0
2B Site Utilities- 0
2C Septic Tank and Effluent Disposal- 0
2D Site Electrical Work- 0
2E Elevated Water Tower- 0
2F Rainwater Collection
3. ANCILLARY FACILITIES
3A Incinerator- 0
3B Ash Pit- 0
3C Placenta Pit- 0
3D Site Security (Fence)- 0
SUB TOTAL Sections 2 and 3- 0
4. CM Temporary Office Facility- 0
TOTAL COST (1+2+3+4)- 0
Total Direct cost After Rebate- 0
Grand Total- 0

&LRefer the desclaimer on the cover page&C&P of &N&R&D

Waiting

Project:Debat,Site 22220-Aug-15
Bid SectionBid ItemDescriptionBill of Quantities
Spec. Div.QuantityUnit% complete
Section 1, Block A - Waiting & Registration
1.00Concrete Work, FoundationDiv 2, 3
1.01Structural Excavation22.19M388%
1.02Lean Concrete, 50 mm thickness6.18M386%
1.03Reinforced Concrete in Grade Beams, C-258.66M390%
1.04Reinforced Concrete in Floor Slab, C-2515.18M386%
1.05Concrete formwork, Ground Contact37.69M286%
1.06Waterproofing Membrane,0.2mm Poly Sheet170.08M290%
1.07Reinforcing Steel, 6mm Dia21.58kg86%
1.08Reinforcing Steel, 12mm Dia212.55kg90%
1.09Reinforcing Steel, 14mm Dia1,349.37kg90%
1.10Reinforcing Steel, 16mm Dia2,164.42kg90%
1.11Reinforcing Steel, 20mm Dia92.70kg90%
1.12Expansion Joint Material, 10mm thickness8.80M20%
Sub-Total
2.00Concrete Work, StructureDiv. 3
2.01Reinforced Concrete in Columns, C-251.56M390%
2.02Reinforced Concrete in Roof Beams, C-252.77M390%
2.03Concrete(steel or timber) formwork for Columns31.20M290%
2.04Concrete(steel or timber) formwork for Roof Beams50.14M290%
2.05Reinforcing Steel, 8mm Dia402.94kg90%
2.06Reinforcing Steel, 12mm Dia434.94kg90%
2.07Reinforcing Steel, 20mm Dia698.23kg90%
Sub-Total
3.00Masonry WorkDiv 4, 9
3.01Hollow Core Concrete Block, Class B, 200mm thickness95.21M290%
3.02Hollow Core Concrete Block, Class B, 150mm thickness31.00M272%
3.03Hollow Core Concrete Block, Class B, 100mm thickness6.30M20%
3.04Terrazzo Wall Cap, 200mm Width17.40ML0%
Sub-Total
4.00Structural SteelDiv 5
The work Includes mortar adjustment.
TRUSS
4.01Cords, Girder Struts, Roof Post, SHS 30x2mm143.83Kg81%
4.02Brace, Girder struts, SHS 25x2mm65.06Kg81%
PURLIN
4.03Roof Purlin, RHS 80x40x2mm330.15Kg81%
4.04Roof Purlin, RHS 80x40x2.5mm220.90Kg81%
STEEL COLUMN
4.05Column, SHS 40x2.5mm with Erection.16.92Kg81%
STEEL PLATES
4.06Steel Plates, 2xFL 60x42-55x5mm10.00Pcs81%
4.07Steel Plates, 2xFL 140x42-72x5mm16.00Pcs81%
4.08Steel Plates, 2xFL 150x120x5mm88.00Pcs81%
4.09Steel Plates, 4xFL 100x150x5mm1.00Pcs81%
4.10Steel Plates, FL 180x150x10mm4.00Pcs81%
4.11Steel Plates, FL 130x65x10mm10.00Pcs81%
4.12Steel Plates, FL 150x70x10mm16.00Pcs81%
4.13Steel Plates, FL 180x65x10mm2.00Pcs81%
4.14Steel Plates, FL 180x80x10mm2.00Pcs81%
4.15Steel Plates, FL 150x150x10mm2.00Pcs81%
4.16Steel End Plate, FL 26x26x2mm8.00Pcs81%
4.17Steel End Plate, FL 36x76x2mm30.00Pcs81%
BOLTS & ANCHOR
CONCRETE WEDGE ANCHOR 15cmx12mm4.00Pcs81%
4.18M12 bolts146.00Pcs81%
Sub-Total
5.00Carpentry and JoineryDiv 6, 9, 10
5.01Suspended Ceiling System (Magn. Board or Grid)38.40M20%
Sub-Total
6.00Roofing, Gutters & Misc. MetalsDiv 5, 7
6.01EGA-500 Roof Panels133.12M20%
6.02G-28 Flat Metal Flashing, Development Length 500mm36.80ML0%
6.03Splalash Trough along Roof Line using Water Proof Membrane22.00ML0%
6.04Splalash Trough along Roof Line U-drainTyp. Including grating4.00ML0%
6.05G-28 Flat Metal Roof Cap, Development Length 550mm17.80ML0%
Sub-Total
7.00Doors & WindowsDiv 6, 8, 12
7.01Door, Type D2A, Steel 90x280mm1.00Pcs0%
7.02Door, Type D3, Wooden 80x280mm1.00Pcs0%
7.03Window/Door Combo, Type WD2, Steel 198x280mm1.00Pcs0%
7.04Window, Type W1, 80x1804.00Pcs0%
7.05Window, Type W2, 80x702.00Pcs0%
7.06Window, Type W4, 90x1801.00Pcs0%
7.07Glazing, 5mm thickness12.69M20%
7.08Window/Door Bar Grills5.18M20%
Sub-Total
8.00FinishingDiv 9
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar177.61M254%
8.02Internal Wall Surface, fine Coat plastering cement/sand177.61M20%
8.03External Wall Surface, fine Coat plastering cement/sand140.31m20%
8.04External HCB Wall Plastering, two Coats Cement/Sand140.31M254%
8.05External HCB Wall Plastering, Slotted, Two Coats Cement/Sand3.20M245%
8.06Floor Mortar, Smooth 48mm thick for Plastic Tile35.72M20%
8.07PVC Floor Tiles35.72M20%
8.08PVC Skirting40.03ML0%
8.09Ceramic Threshold, Door, 8mm Thickness12.15ML0%
8.10Plastic Emulsion Paint, three Coats on Internal Plaster116.01M20%
8.11Synthetic Enamel Paint, three Coats on Internal Plaster61.59M20%
8.12Plastic Emulsion Paint, three Coats on External Plaster140.31M20%
8.13Floor Mortar, Smooth 20 mm thick for terrazzo Tile66.24M20%
8.14Terrazzo tile flooring66.24m20%
8.15Terrazzo tile Skirting38.95ml0%
8.16Terrazzp Window Sill, Chmfered with Drip Ledge6.00ml0%
8.17Broom-Finish on Monolithic Concrete Slab12.95M20%
Sub-Total
9.00SpecialtiesDiv 10, 12, 15
9.01Signs, Type 12.00Pcs0%
9.02Signs, Type 32.00Pcs0%
9.03Signs, Type 41.00Pcs0%
9.04Fire Extinguisher, 6 Kg1.00Pcs0%
9.05Steel framed Wooden Benches Type A7.00Pcs0%
9.06Marble plaque (40cmX80cmx3cm) on plastered masonry stand1.00Pcs0%
Sub-Total
10.00Sanitary FixturesDiv 10, 15
Sub-Total
11.00ElectricalDiv 16
11.01Flush mounted Distribution Board size 400x125x200mm, LPP-A, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 25A/1Phase ACB, 2 pcs 10A/1Phase MCBs, 2 pcs 16A/1Phase MCBs, 3 pcs 16A/1Phase GFCI MCBs1.00No0%
11.02Electric Cable, Multi-Core Copper, PVC/PVC Coated, Color Coded in 50mm diam PVC Pipe, 3x4mm sq. with Red warning tape from MSB45.00ML0%
11.03Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x2.5mm sq. inside PVC conduit of 16mm diameter, including junction boxes with covers and insulating screw cap connectors, complete12.00No0%
11.04Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x1.5mm sq. inside PVC conduit of 16mm diameter From Battery and Inverter Pack, including junction boxes with covers and insulating screw cap connectors, complete1.00No0%
11.05Light Switch Flush Mounted, Single Switch2.00No0%
11.06Light Switch Flush Mounted, Double Switch3.00No0%
11.0716A/1Phase flush mounted socket outlet point fed through PVC insulated color coded copper conductors of 3x2.5mm sq. inside PVC conduit of 16mm diameter including junction boxes with covers and insulating screw cap connectors9.00No0%
11.08Outlet Socket Flush Mounted, Earth Contact 16A 1 Phase4.00No0%
11.09Outlet Socket Flush Mounted, Earth Contact 16A 1 Phase with cover1.00No0%
11.10Outlet Socket Flush Mounte Twin Socket, Earth Contact 16A 1 Phase4.00No0%
11.11Light Fixtures, Type 25.00No0%
11.12Light Fixtures, Type 47.00No0%
11.13Light Fixtures, Type 6.1, Feed From Battery Pack1.00No0%
11.14Surface Mtd., Enclosed Patch Panel with (1x24) I/O Termination Points, XL Brand1.00No0%
11.15CAT 6E Full Copper Cable with Terminations & Testing and Interior Conduit, 20mm diameter PVC32.00ML0%
11.16Telephone/Data Outlet Box with (2) RJ 45 Connections3.00No0%
Sub-Total
Section Total

OPD

Project:Debat,Site 22220-Aug-15
Bid SectionBid ItemDescriptionBill of Quantities
Spec. Div.QuantityUnit% complete
Section 1, Block B - Out Patient Department
1.00Concrete Work, FoundationDiv 2, 3
1.01Structural Excavation46.29M388%
1.02Lean Concrete, 50 mm thickness13.43M386%
1.03Reinforced Concrete in Grade Beams, C-2518.86M390%
1.04Reinforced Concrete in Floor Slab, C-2533.82M386%
1.05Concrete formwork, Ground Contact95.21M286%
1.06Waterproofing Membrane, 0.2mm Poly Sheet345.12M290%
1.07Reinforcing Steel, 8mm Dia120.00kg86%
1.08Reinforcing Steel, 12mm Dia85.79kg86%
1.09Reinforcing Steel, 14mm Dia2,635.62kg90%
1.10Reinforcing Steel, 16mm Dia5,680.29kg90%
1.11Reinforcing Steel, 20mm Dia331.29kg90%
1.12Expansion Joint Material, 10mm thickness9.42M20%
Sub-Total
2.00Concrete Work, StructureDiv. 3
2.01Reinforced Concrete in Columns, C-253.12M30%
2.02Reinforced Concrete in Roof Beams, C-256.22M30%
2.03Concrete(steel or timber) formwork for Columns62.40M20%
2.04Concrete(steel or timber) formwork for Roof Beams91.28M20%
2.05Reinforcing Steel, 8mm Dia581.19kg0%
2.06Reinforcing Steel, 12mm Dia825.51kg0%
2.07Reinforcing Steel, 20mm Dia1,348.36kg0%
Sub-Total
3.00Masonry WorkDiv 4, 9
3.01Hollow Core Concrete Block, Class B, 200mm thickness363.49M20%
3.02Hollow Core Concrete Block, Class B, 150mm thickness183.00M20%
3.03Hollow Core Concrete Block, Class B, 100mm thickness4.62M20%
Sub-Total
4.00Structural SteelDiv 5
The work Includes mortar adjustment.
TRUSS
4.01Cords, Girder Struts, Roof Post, SHS 30x2mm359.65Kg0%
4.02Brace, Girder struts, SHS 25x2mm36.69Kg0%
4.03Rafter 100x60x2.5mm, Awning28.01Kg0%
PURLIN
4.04Roof Purlin, RHS 80x40x2mm731.94Kg0%
4.05Roof Purlin, RHS 80x40x2.5mm690.11Kg0%
COLUMN
4.06Steel Column SHS 40x2.5mm16.92Kg0%
PLATES
4.07Steel Plates, 2xFL 60x42-55x5mm12.00Pcs0%
4.08Steel Plates, 2xFL 140x42-72x5mm12.00Pcs0%
4.08Steel Plates, 2xFL 150x120x5mm174.00Pcs0%
4.09Steel Plates, 2xFL 60x57x5mm12.00Pcs0%
4.10Steel Plates, 2xFL 180x60x10mm2.00Pcs0%
4.11Steel Plates, FL 180x150x10mm12.00Pcs0%
4.12Steel Plates, FL 150x70x10mm36.00Pcs0%
4.13Steel Plates, FL 180x65x10mm24.00Pcs0%
4.14Steel Plates, FL 150x150x10mm2.00Pcs0%
4.15Steel Plates, FL 100x36x5mm20.00Pcs0%
4.16Steel Plates, FL 100x55x5mm8.00Pcs0%
4.17Steel Plates, FL 110x32x5mm8.00Pcs0%
4.18Steel End Plate, FL 21x21x2mm20.00Pcs0%
4.19Steel End Plate, FL 26x26x2mm12.00Pcs0%
4.20Steel End Plate, FL 36x76x2mm34.00Pcs0%
4.21Steel End Plate, FL 96x56x2mm2.00Pcs0%
BOLTS & ANCHORAGES
4.22M12 bolts316.00Pcs0%
4.2315cmx12mm Concrete Wedge Anchor4.00Pcs0%
Sub-Total
5.00Carpentry and JoineryDiv 6, 9, 10
5.01Suspended Ceiling System (Magn. Board or Grid)166.03M20%
5.02PVC Ceiling System26.80M20%
5.03Cabinets, with Standard Lab Sink1.00Pcs0%
5.04Nurse station Counter including door1.00Pcs0%
Sub-Total
6.00Roofing, Gutters & Misc. MetalsDiv 5, 7
6.01EGA-500 Roof Panels299.02M20%
6.02Danpalon Roof Panels23.28M20%
6.03Wire Mesh with Framing8.00M20%
6.04G-28 Flat Metal Flashing, Development Length 500mm40.80ML0%
6.05G-28 Flat Metal Roof Cap, Development Length 550mm24.40ML0%
6.06Splalash Trough along Roof Line using Water Proof Membrane41.00ML0%
Sub-Total
7.00Doors & WindowsDiv 6, 8, 12
7.01Door, Type D1, Wooden 120x280mm1.00Pcs0%
7.02Door, Type D1A, Steel 120x280mm1.00Pcs0%
7.03Door, Type D2, Wooden 90x280mm11.00Pcs0%
7.04Door, Type D7, wooden\ 80x280mm2.00Pcs0%
7.05Window, Type W1, 80x18020.00Pcs0%
7.06Window, Type W1A, 80x1803.00Pcs0%
7.06Window, Type W2, 80x701.00Pcs0%
7.07Glazing32.79M20%
Sub-Total
8.00FinishingDiv 9
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar784.98M20%
8.02Internal Wall Surface, fine Coat plastering cement/sand784.98M20%
8.03External Wall Surface, fine Coat plastering cement/sand253.00m20%
8.04External HCB Wall Plastering, Two Coats Cement/Sand253.00M20%
8.05External HCB Wall Plastering, Slotted, Two Coats Cement/Sand16.00M20%
8.06Floor Mortar, Smooth 48mm thick for Plastic Tile157.68M20%
8.07Floor Mortar, Smooth 40mm thick for 10mm Ceramic Tile53.07M20%
8.08PVC Floor Tiles157.68M20%
8.09PVC Skirting179.48ML0%
8.10Ceramic Floor Tile,Non Slip, 10mm thickness53.07M20%
8.11Ceramic Threshold, Door, 8mm Thickness14.55ML0%
8.12Ceramic Tile Skirting58.97ML0%
8.13Epoxy Floor Finish, Chemical Resistant, Self Leveling26.60M20%
8.14Epoxy Skirting29.91M20%
8.15Terrazzo Window Sill, Chamfered with Drip Ledge18.90ML0%
8.16Plastic Emulsion Paint, three Coats on Internal Plaster652.73M20%
8.17Synthetic Enamel Paint, three Coats on Internal Plaster132.25M20%
8.18Plastic Emulsion Paint, three Coats on External Plaster520.48253.00M20%
8.19Ceramic Wall Tile18.72M20%
8.20Broom-Finish on Concrete Slab6.48M20%
Sub-Total
9.00SpecialtiesDiv 10, 12, 15
9.01Signs, Type 114.00Pcs0%
9.02Signs, Type 31.00Pcs0%
9.03Signs, Type 41.00Pcs0%
9.04Toilet Accessory, Stainless Steel Grab Bar, 32mmx 500mm2.00Pcs0%
9.05Fire Extinguisher, 6 Kg1.00Pcs0%
9.06Steel framed Wooden Benches Type B2.00Pcs0%
9.07Steel framed Wooden Benches Type C7.00Pcs0%
Sub-Total
10.00Sanitary FixturesDiv 10, 15
10.01Vitreous Hand Wash Basin with Fittings3.00No0%
10.02Stailess Steel Laboratory Sink with Fittings, Chemical Resistant1.00No0%
10.03Stainless Steel Handwash Basin with fittings2.00No0%
10.04Electric Water Heater, 50 Liter with fittings2.00No0%
10.05Polypropylene (PPR-PN20) Water Pipe, 20mm9.00ML0%
10.06Polypropylene (PPR-PN20) Water Pipe, 25mm63.54ML0%
10.07Stop Valves, 20mm19.00No0%
10.08uPVC Waste and Vent Pipe. 50mm10.00ML18%
10.09uPVC Waste and Vent Pipe. 80mm21.74ML63%
10.10uPVC Waste and Vent Pipe. 110mm2.00ML0%
10.11uPVC Vent Cap, 110mm6.00No0%
10.12Stainless Steel Compact Handwash Basin, 23x39mm1.00No0%
Sub-Total
11.00ElectricalDiv 16
11.01Flush mounted Distribution Board size 500x150x600mm, LPP-B, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 50A/3Phase ACB, 5 pcs 10A/1Phase MCBs,3 pcs 16A/1Phase MCBs, 15 pcs 16A/1Phase GFCI MCBs.1.00No0%
11.02Flush mounted Distribution Board size 400x125x200mm, LPP-Battery, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 16A/1Phase MCB, 2 pcs 10A/1Phase MCBs.1.00No0%
11.03Battery, Sealed Lead Acid 12V, 2x200Ah Train or equivalent Brand with Inverter (Siemense or Equivalent brand) 220VAC input and 12VDC output to Battery and 220VAC output to Load, with Enclosed Rack for Battery and Inverter1.00Set0%
11.04Electric Cable, Multi-Core Copper, PVC/PVC Coated, Color Coded in 50 mm diam PVC pipe, 5x10mm sq. with Red warning tape25.00ML0%
11.05Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x2.5mm sq. inside PVC conduit of 16mm diameter, including junction boxes with covers and insulating screw cap connectors, complete42.00No0%
11.06Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x1.5mm sq. inside PVC conduit of 16mm diameter From Battery and Inverter Pack, including junction boxes with covers and insulating screw cap connectors, complete3.00No0%
11.07Light Switch Flush Mounted, Single Switch4.00No0%
11.08Light Switch Flush Mounted, Single Switch Water Proof1.00No0%
11.09Light Switch Flush Mounted, Double Switch11.00No0%
11.10Light Switch Flush Mounted, Two-Way Switch4.00No0%
11.1116A/1Phase flush mounted socket outlet point fed through PVC insulated color coded copper conductors of 3x2.5mm sq. inside PVC conduit of 16mm diameter including junction boxes with covers and insulating screw cap connectors48.00No0%
11.12Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase23.00No0%
11.13Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase with cover6.00No0%
11.14Outlet Socket Flush Mounte Twin Socket, Earth Contact 16A 1 Phase15.00No0%
11.15Outlet Socket Flush Mounted Twin Socket, Earth Contact 16A 1 Phase with cover2.00No0%
11.16Outlet Socket Twin Flush Mounted, Earth Contact 16A 1 Phase for Water Heater2.00No0%
11.17Light Fixtures, Type 27.00No0%
11.18Light Fixtures, Type 34.00No0%
11.19Light Fixtures, Type 429.00No0%
11.20Light Fixtures, Type 51.00No0%
11.21Light Fixtures, Type 61.00No0%
11.22Light Fixtures, Type 5.1,Feed From Battery Pack2.00No0%
11.23Light Fixtures, Type 6.1, Feed From Battery Pack1.00No0%
11.24Surface Mtd., Enclosed Patch Panel with (1x24) I/O Termination Points, XL Brand2.00No0%
11.25CAT 6E Full Copper Cable with Terminations & Testing and Interior Conduit, 20mm diameter PVC160.00ML0%
11.26Telephone/Data Outlet Box with (2) RJ 45 Connections12.00No0%
Sub-Total
Section Total

Admin

Project:Debat,Site 22220-Aug-15
Bid SectionBid ItemDescriptionBill of Quantities
Spec. Div.QuantityUnit% complete
Section 1, Block C - Administration & Pharmacy
1.00Concrete Work, FoundationDiv 2, 3
1.01Structural Excavation29.16M388%
1.02Lean Concrete, 50 mm thickness8.40M386%
1.03Reinforced Concrete in Grade Beams, C-2511.83M390%
1.04Reinforced Concrete in Floor Slab, C-2520.86M386%
1.05Concrete formwork, Ground Contact82.26M286%
1.06Waterproofing Membrane, 0.2mm Poly Sheet210.88M290%
1.07Reinforcing Steel, 8mm Dia120.00kg86%
1.08Reinforcing Steel, 12mm Dia65.47kg86%
1.09Reinforcing Steel, 14mm Dia1,658.94kg90%
1.10Reinforcing Steel, 16mm Dia3,279.68kg90%
1.11Reinforcing Steel, 20mm Dia192.56kg90%
1.12Expansion Joint Material, 10mm thickness1.53M20%
Sub-Total
2.00Concrete Work, StructureDiv. 3
2.01Reinforced Concrete in Columns, C-252.08M390%
2.02Reinforced Concrete in Roof Beams, C-253.90M390%
2.03Concrete(steel or timber) formwork for Columns41.60M290%
2.04Concrete(steel or timber) formwork for Roof Beams56.88M290%
2.05Reinforcing Steel, 8mm Dia348.19kg90%
2.06Reinforcing Steel, 12mm Dia592.78kg90%
2.07Reinforcing Steel, 20mm Dia939.54kg90%
Sub-Total
3.00Masonry WorkDiv 4, 9
3.01Hollow Core Concrete Block, Class B, 200mm thickness208.38M290%
3.02Hollow Core Concrete Block, Class B, 150mm thickness83.74M263%
3.03Hollow Core Concrete Block, Class B, 100mm thickness4.62M20%
Sub-Total
4.00Structural SteelDiv 5
The work Includes mortar adjustment.
TRUSS
4.01Cords, Girder Struts, Roof Post, SHS 30x2mm239.77Kg81%
4.02Brace, Girder struts, SHS 25x2mm29.54Kg81%
4.03Rafter 100x60x2.5mm, Awning28.01Kg81%
PURLIN
4.04Roof Purlin, RHS 80x40x2mm458.53Kg81%
4.05Roof Purlin, RHS 80x40x2.5mm437.24Kg81%
COLUMN
4.06Steel Column SHS 40x2.5mm16.92Kg81%
PLATES
4.07Steel Plates, 2xFL 60x42-55x5mm8.00Pcs81%
4.08Steel Plates, 2xFL 140x42-72x5mm8.00Pcs81%
4.09Steel Plates, 2xFL 150x120x5mm112.00Pcs81%
4.10Steel Plates, 2xFL 60x57x5mm8.00Pcs81%
4.11Steel Plates, 2xFL 180x60x10mm2.00Pcs81%
4.12Steel Plates, FL 180x150x10mm8.00Pcs81%
4.13Steel Plates, FL 150x70x10mm16.00Pcs81%
4.14Steel Plates, FL 180x65x10mm16.00Pcs81%
4.15Steel Plates, FL 150x150x10mm2.00Pcs81%
4.16Steel Plates, FL 100x36x5mm16.00Pcs81%
4.17Steel Plates, FL 100x55x5mm8.00Pcs81%
4.18Steel Plates, FL 110x32x5mm8.00Pcs81%
4.19Steel End Plate, FL 21x21x2mm16.00Pcs81%
4.20Steel End Plate, FL 26x26x2mm8.00Pcs81%
4.21Steel End Plate, FL 36x76x2mm34.00Pcs81%
4.22Steel End Plate, FL 96x56x2mm2.00Pcs81%
BOLTS & ANCHORAGES
4.23M12 bolts192.00Pcs81%
4.2415cmx12mm Concrete Wedge Anchor4.00Pcs81%
Sub-Total
5.00Carpentry and JoineryDiv 6, 9, 10
5.01Suspended Ceiling System (Magn. Board or Grid)111.20M20%
5.02Dispensary Counter1.00M20%
Sub-Total
6.00Roofing, Gutters & Misc. MetalsDiv 5, 7
6.01EGA-500 Roof Panels173.80M20%
6.02Danpalon Roof Panels11.52M20%
6.03Wire Mesh with Framing4.50M20%
6.04G-28 Flat Metal Flashing, Development Length 500mm36.00ML0%
6.05Splalash Trough along Roof Line using Water Proof Membrane22.00ML0%
6.06Splalash Trough along Roof Line U-drainTyp. Including grating2.50ML0%
6.07G-28 Flat Metal Roof Cap, Development Length 550mm21.68ML0%
Sub-Total
7.00Doors & WindowsDiv 6, 8, 12
7.01Door, Type D2, Wooden90x280mm7.00Pcs0%
7.02Window, Type W1, 80x1804.00Pcs0%
7.03Window, Type W1A, 80x1809.00Pcs0%
7.04Glazing18.72M20%
7.05Window/Door Bar Grills12.96M20%
Sub-Total
8.00FinishingDiv 9
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar442.76M272%
8.02Internal Wall Surface, fine Coat plastering cement/sand442.76M20%
8.03External Wall Surface, fine Coat plastering cement/sand190.00m20%
8.04External HCB Wall Plastering, Two Coats Cement/Sand190.00M268%
8.04'External HCB Wall Plastering, Slotted, Two Coats Cement/Sand10.40M268%
8.05Floor Mortar, Smooth 48mm thick for Plastic Tile111.20M20%
8.06Floor Mortar, Smooth 40mm for 10mm Ceramic Tile26.28M20%
8.07PVC Floor Tiles111.20M20%
8.08PVC Skirting103.60ML0%
8.09Ceramic Floor Tiles, Non-slip, 10mm thickness26.28M20%
8.10Ceramic Tile Skirting33.80ML0%
8.11Ceramic Threshold, Door, 8mm Thickness6.30ML0%
8.12Terrazzo Window Sill, Chamfered with Drip Ledge10.40ML0%
8.13Plastic Emulsion Paint, three Coats on Internal Plaster398.32M20%
8.14Synthetic Enamel Paint, three Coats on Internal Plaster42.64M20%
8.15Plastic Emulsion Paint, three Coats on External Plaster190.00M20%
8.16Broom-Finish on Concrete Slab6.60M20%
Sub-Total
9.00SpecialtiesDiv 10, 12, 150%
9.01Signs, Type 15.00Pcs0%
9.02Signs, Type 22.00Pcs0%
9.03Signs, Type 32.00Pcs0%
9.04Signs, Type 41.00Pcs0%
9.05Toilet Accessory, Mirror2.00Pcs0%
9.06Toilet Accessory, Ceramic Soap Holder 185x95mm3.00Pcs0%
9.07Toilet Accessory, Stainless Steel Grab Bar, 32mmx 500mm2.00Pcs0%
9.08Toilet Accessory, Chrome Towel Rail2.00Pcs0%
9.09Fire Extinguisher, 6 Kg1.00Pcs0%
Sub-Total
10.00Sanitary FixturesDiv 10, 15
10.01Stainless Steel Handwash Basin with fittings1.00No0%
10.02Polypropylene (PPR-PN20) Water Pipe, 25mm8.00ML0%
10.03Stop Valves, 20mm1.00No0%
10.04uPVC Waste and Vent Pipe. 50mm2.00ML18%
10.05uPVC Waste and Vent Pipe. 80mm4.00ML63%
10.06uPVC Waste and Vent Pipe. 110mm5.00ML0%
10.07uPVC Vent Cap, 110mm1.00No0%
Sub-Total
11.00ElectricalDiv 16
11.01Flush mounted Distribution Board size 400x150x500mm, LPP-C, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 25A/3Phase ACB, 3 pcs 10A/1Phase MCBs, 3 pcs 16A/1Phase MCBs, 6 pcs 16A/1Phase GFCI MCBs.1.00No0%
11.02Electric Cable, Multi-Core Copper, PVC/PVC Coated, Color Coated in 50mm diam PVC pipe, 5x4 mm sq. with Red warning tape30.00ML0%
11.03Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x2.5mm sq. inside PVC conduit of 16mm diameter, including junction boxes with covers and insulating screw cap connectors, complete22.00No0%
11.04Light Switch Flush Mounted, Double Switch7.00No0%
11.05Light Switch Flush Mounted, Two-Way Switch2.00No0%
11.0616A/1Phase flush mounted socket outlet point fed through PVC insulated color coded copper conductors of 3x2.5mm sq. inside PVC conduit of 16mm diameter including junction boxes with covers and insulating screw cap connectors19.00No0%
11.07Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase7.00No0%
11.08Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase with cover2.00No0%
11.09Outlet Socket Flush Mounted Twin Socket, Earth Contact 10-16A/16A 1 Phase10.00No0%
11.10Light Fixtures, Type 24.00No0%
11.11Light Fixtures, Type 418.00No0%
11.12Surface Mtd., Enclosed Patch Panel with (1x24) Termination Points1.00No0%
11.13CAT 6E Full Copper Cable with Terminations & Testing and Interior Conduit, 20mm diameter PVC50.00ML0%
11.14Telephone/Data Outlet Box with (2) RJ 45 Connections3.00No0%
Sub-Total
Section Total

LabDel

Project:Debat,Site 22220-Aug-15
Bid SectionBid ItemDescriptionBill of Quantities
Spec. Div.QuantityUnit% complete
Section 1, Block D - Delivery
1.00Concrete Work, FoundationDiv 2, 3
1.01Structural Excavation29.87M388%
1.02Lean Concrete, 50 mm thickness17.68M386%
1.03Reinforced Concrete in Grade Beams, C-2512.60M390%
1.04Reinforced Concrete in Floor Slab, C-2522.08M386%
1.05Concrete formwork, Ground Contact71.51M286%
1.06Waterproofing Membrane, 0.2mm Poly Sheet229.36M290%
1.07Reinforcing Steel, 8mm Dia120.00kg86%
1.08Reinforcing Steel, 12mm Dia74.46kg86%
1.09Reinforcing Steel, 14mm Dia1,649.00kg90%
1.10Reinforcing Steel, 16mm Dia3,399.74kg90%
1.11Reinforcing Steel, 20mm Dia192.56kg90%
1.12Expansion Joint Material, 10mm thickness3.06M20%
Sub-Total
2.00Concrete Work, StructureDiv. 3
2.01Reinforced Concrete in Columns, C-252.08M390%
2.02Reinforced Concrete in Roof Beams, C-254.00M390%
2.03Concrete(steel or timber) formwork for Columns41.60M290%
2.04Concrete(steel or timber) formwork for Roof Beams60.00M290%
2.05Reinforcing Steel, 8mm Dia386.90kg90%
2.06Reinforcing Steel, 12mm Dia617.51kg90%
2.07Reinforcing Steel, 20mm Dia1,348.36kg90%
Sub-Total
3.00Masonry WorkDiv 4, 9
3.01Hollow Core Concrete Block, Class B, 200mm thickness295.19M290%
3.02Hollow Core Concrete Block, Class B, 150mm thickness95.50M263%
3.03Hollow Core Concrete Block, Class B, 100mm thickness5.67M20%
Sub-Total
4.00Structural SteelDiv 5
The work Includes mortar adjustment.
TRUSS
4.01Cords, Girder Struts, Roof Post, SHS 30x2mm248.37Kg81%
4.02Brace, Girder struts, SHS 25x2mm33.15Kg81%
4.03Rafter 100x60x2.5mm, Awning28.01Kg81%
PURLIN
4.04Roof Purlin, RHS 80x40x2mm458.53Kg81%
4.05Roof Purlin, RHS 80x40x2.5mm384.56Kg81%
COLUMN
4.06Steel Column SHS 40x2.5mm16.92Kg81%
PLATES
4.07Steel Plates, 2xFL 60x42-55x5mm8.00Pcs81%
4.08Steel Plates, 2xFL 140x42-72x5mm8.00Pcs81%
4.09Steel Plates, 2xFL 150x120x5mm112.00Pcs81%
4.10Steel Plates, 2xFL 60x57x5mm8.00Pcs81%
4.11Steel Plates, 2xFL 180x60x10mm2.00Pcs81%
4.12Steel Plates, FL 180x150x10mm8.00Pcs81%
4.13Steel Plates, FL 150x70x10mm16.00Pcs81%
4.14Steel Plates, FL 180x65x10mm16.00Pcs81%
4.15Steel Plates, FL 150x150x10mm2.00Pcs81%
4.16Steel Plates, FL 100x36x5mm16.00Pcs81%
4.17Steel Plates, FL 100x55x5mm8.00Pcs81%
4.18Steel Plates, FL 110x32x5mm8.00Pcs81%
4.19Steel End Plate, FL 21x21x2mm16.00Pcs81%
4.20Steel End Plate, FL 26x26x2mm8.00Pcs81%
4.21Steel End Plate, FL 36x76x2mm34.00Pcs81%
BOLTS & ANCHORAGES
4.22M12 bolts192.00Pcs81%
4.2315cmx12mm Concrete Wedge Anchor4.00Pcs81%
Sub-Total
5.00Carpentry and JoineryDiv 6, 9, 10
5.01Suspended Ceiling System (Magn. Board or Grid)54.30M20%
5.02PVC Ceiling System54.30M20%
5.03Nurse station Counter including door1.00Pcs0%
Sub-Total
6.00Roofing, Gutters & Misc. MetalsDiv 5, 7
6.01EGA-500 Roof Panels187.64M20%
6.02Danpalon Roof Panels12.48M20%
6.03Wire Mesh with Framing4.50M20%
6.04G-28 Flat Metal Flashing, Development Length 500mm37.60ML0%
6.05Splalash Trough along Roof Line using Water Proof Membrane29.20ML0%
6.08G-28 Flat Metal Roof Cap, Development Length 550mm20.20ML0%
Sub-Total
7.00Doors & WindowsDiv 6, 8, 12
7.01Door, Type D1, Wooden 120x280mm7.00Pcs0%
7.02Door, Type D2, Wooden 90x280mm2.00Pcs0%
7.03Door, Type D3, Wooden 80x280mm3.00Pcs0%
7.04Door, Type D3A, Steel 80x280mm2.00Pcs0%
7.05Door, Type D4, Steel 160x280mm2.00Pcs0%
7.06Door, Type D7, Wooden 80x280mm1.00Pcs0%
7.07Window, Type W1, 80x1809.00Pcs0%
7.08Window, Type W2, 80x701.00Pcs0%
7.09Glazing15.68M20%
Sub-Total
8.00FinishingDiv 9
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar406.26M245%
8.02Internal Wall Surface, fine Coat plastering cement/sand408.34M20%
8.03External Wall Surface, fine Coat plastering cement/sand174.00m20%
8.04External HCB Wall Plastering, Two Coats Cement/Sand174.00M254%
8.05External HCB Wall Plastering, Slotted, Two Coats Cement/Sand5.60M254%
8.06Floor Mortar, Smooth 48mm thick for Plastic Tile45.00M20%
8.07Floor Mortar, Smooth 40mm for 10mm Ceramic Tile37.70M20%
8.08PVC Floor Tiles45.00M20%
8.09PVC Skirting53.00ML0%
8.10Ceramic Floor Tiles, Non-slip, 10mm thickness37.70M20%
8.11Ceramic Tile Skirting42.80ML0%
8.12Ceramic Threshold, Door, 8mm Thickness17.70ML0%
8.13Epoxy Floor Finish, Chemical Resistant, Self Leveling28.00M20%
8.14Epoxy Skirting35.20M20%
8.15Terrazzo Window Sill, Chamfered with Drip Ledge8.50ML0%
8.16Plastic Emulsion Paint, three Coats on Internal Plaster200.96M20%
8.17Synthetic Enamel Paint, three Coats on Internal Plaster91.26M20%
8.18Plastic Emulsion Paint, three Coats on External Plaster174.00M20%
8.19Acrylic Wall Coating System98.56m20%
8.20Ceramic Wall Tile15.48M20%
8.21Broom-Finish on Concrete Slab5.50M20%
Sub-Total
9.00SpecialtiesDiv 10, 12, 15
9.01Signs, Type 111.00Pcs0%
9.02Signs, Type 23.00Pcs0%
9.03Signs, Type 31.00Pcs0%
9.04Signs, Type 41.00Pcs0%
9.05Toilet Accessory, Paper Holder1.00Pcs0%
9.06Toilet Accessory, Mirror5.00Pcs0%
9.07Toilet Accessory, Ceramic Soap Holder 185x95mm5.00Pcs0%
9.08Toilet Accessory, Stainless Steel Grab Bar, 32mmx 500mm4.00Pcs0%
9.09Toilet Accessory, Chrome Towel Rail1.00Pcs0%
9.10Fire Extinguisher, 6 Kg1.00Pcs0%
Sub-Total
10.00Sanitary FixturesDiv 10, 15
10.01Vitreous Water Closet with fittings (Eastern-Style)1.00No0%
10.02Vitreous Hand Wash Basin with Fittings1.00No0%
10.03Stainless Steel Sluice Sink with Fittings1.00No0%
10.04Stainless Steel Scrub Sink with Fittings1.00No0%
10.05Shower Installation, Ceramic Tile Pan, Complete1.00No0%
10.06Electric Water Heater, 50 Liter with fittings2.00No0%
10.07Electric Water Heater, 80 Liter with fittings (Not installed under PV Option)1.00No0%
10.08Polypropylene (PPR-PN20) Water Pipe, 20mm4.00ML0%
10.09Polypropylene (PPR-PN20) Water Pipe, 25mm40.00ML0%
10.10Stop Valves, 20mm11.00No0%
10.11uPVC Waste and Vent Pipe. 50mm12.00ML18%
10.12uPVC Waste and Vent Pipe. 80mm10.00ML63%
10.13uPVC Waste and Vent Pipe. 110mm36.00ML63%
10.14uPVC Vent Cap, 110mm2.00No0%
10.15Floor Drain with Trap, 50mm1.00No0%
Sub-Total
11.00ElectricalDiv 16
11.01Flush mounted Distribution Board size 400x150x500mm, LPP-D, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 40A/3Phase ACB, 3 pcs 10A/1Phase MCBs, 3 pcs 16A/1Phase MCBs, 9 pcs 16A/1Phase GFCI MCBs.1.00No0%
11.02Electric Cable, Multi-Core Copper, PVC/PVC Coated, Color Coded in 50mm diam PVC pipe, 5x6mm sq. with warning tape40.00ML0%
11.03Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x2.5mm sq. inside PVC conduit of 16mm diameter, including junction boxes with covers and insulating screw cap connectors, complete27.00No0%
11.04Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x1.5mm sq. inside PVC conduit of 16mm diameter From Battery and Inverter Pack, including junction boxes with covers and insulating screw cap connectors, complete6.00No0%
11.05Light Switch Flush Mounted, Single Switch9.00No0%
11.06Light Switch Flush Mounted, Single Switch, Water Proof1.00No0%
11.07Light Switch Flush Mounted, Double Switch5.00No0%
11.08Light Switch Flush Mounted, Two-Way Switch8.00No0%
11.0916A/1Phase flush mounted socket outlet point fed through PVC insulated color coded copper conductors of 3x2.5mm sq. inside PVC conduit of 16mm diameter including junction boxes with covers and insulating screw cap connectors28.00No0%
11.10Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase15.00No0%
11.11Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase with cover6.00No0%
11.12Outlet Socket Flush Mounted Twin Socket, Earth Contact 10-16A/16A 1 Phase4.00No0%
11.13Outlet Socket Twin Flush Mounted, Earth Contact 10-16A/16A 1 Phase for Water Heater3.00No0%
11.14Light Fixtures, Type 12.00No0%
11.15Light Fixtures, Type 26.00No0%
11.16Light Fixtures, Type 35.00No0%
11.17Light Fixtures, Type 410.00No0%
11.18Light Fixtures, Type 51.00No0%
11.19Light Fixtures, Type 61.00No0%
11.20Light Fixtures, Type 5.1, Feed From Battery Pack5.00No0%
11.21Light Fixtures, Type 6.1,Feed From Battery Pack1.00No0%
11.22Light Fixtures, Type 72.00No0%
11.23Telephone/Data Outlet Box with (2) RJ 45 Connections1.00No0%
Sub-Total
Section Total

IPD

Project:Debat,Site 22220-Aug-15
Bid SectionBid ItemDescriptionBill of Quantities
Spec. Div.QuantityUnit% complete
Section 1, Block E - Inpatient Department
1.00Concrete Work, FoundationDiv 2, 3
1.01Structural Excavation21.13M388%
1.02Lean Concrete, 50 mm thickness12.18M386%
1.03Reinforced Concrete in Grade Beams, C-259.34M390%
1.04Reinforced Concrete in Floor Slab, C-2514.96M386%
1.05Concrete formwork, Ground Contact66.82M286%
1.06Waterproofing Membrane, 0.2mm Poly Sheet143.89M290%
1.07Reinforcing Steel, 8mm Dia120.00kg86%
1.08Reinforcing Steel, 12mm Dia66.64kg86%
1.09Reinforcing Steel, 14mm Dia1,097.91kg90%
1.10Reinforcing Steel, 16mm Dia2,124.02kg90%
1.11Reinforcing Steel, 20mm Dia123.09kg90%
1.12Expansion Joint Material, 10mm thickness3.06M20%
Sub-Total
2.00Concrete Work, StructureDiv. 3
2.01Reinforced Concrete in Columns, C-251.56M390%
2.02Reinforced Concrete in Roof Beams, C-252.82M390%
2.03Concrete(steel or timber) formwork for Columns31.20M290%
2.04Concrete(steel or timber) formwork for Roof Beams45.12M290%
2.05Reinforcing Steel, 8mm Dia255.39kg90%
2.06Reinforcing Steel, 12mm Dia429.15kg90%
2.07Reinforcing Steel, 20mm Dia707.14kg90%
Sub-Total
3.00Masonry WorkDiv 4, 9
3.01Hollow Core Concrete Block, Class B, 200mm thickness225.11M245%
3.02Hollow Core Concrete Block, Class B, 150mm thickness82.31M245%
3.03Hollow Core Concrete Block, Class B, 100mm thickness11.50M20%
Sub-Total
4.00Structural SteelDiv 5
The work Includes mortar adjustment.
TRUSS
4.01Cords, Girder Struts, Roof Post, SHS 30x2mm186.28Kg81%
4.02Brace, Girder struts, SHS 25x2mm28.67Kg81%
4.03Rafter 100x60x2.5mm, Awning28.01Kg81%
PURLIN
4.04Roof Purlin, RHS 80x40x2mm279.10Kg81%
4.05Roof Purlin, RHS 80x40x2.5mm310.81Kg81%
COLUMN
4.06Steel Column SHS 40x2.5mm16.92Kg81%
PLATES
4.07Steel Plates, 2xFL 60x42-55x5mm6.00Pcs81%
4.08Steel Plates, 2xFL 140x42-72x5mm7.00Pcs81%
4.09Steel Plates, 2xFL 150x120x5mm84.00Pcs81%
4.10Steel Plates, 2xFL 60x57x5mm6.00Pcs81%
4.11Steel Plates, 2xFL 180x60x10mm2.00Pcs81%
4.12Steel Plates, FL 180x150x10mm7.00Pcs81%
4.13Steel Plates, FL 150x70x10mm12.00Pcs81%
4.14Steel Plates, FL 180x65x10mm12.00Pcs81%
4.15Steel Plates, FL 150x150x10mm2.00Pcs81%
4.16Steel Plates, FL 100x36x5mm14.00Pcs81%
4.17Steel Plates, FL 100x55x5mm8.00Pcs81%
4.18Steel Plates, FL 110x32x5mm8.00Pcs81%
4.19Steel End Plate, FL 21x21x2mm14.00Pcs81%
4.20Steel End Plate, FL 26x26x2mm7.00Pcs81%
4.21Steel End Plate, FL 36x76x2mm34.00Pcs81%
4.22Steel End Plate, FL 96x56x2mm2.00Pcs81%
BOLTS & ANCHORAGES
4.23M12 bolts158.00Pcs81%
4.2415cmx12mm Concrete Wedge Anchor4.00Pcs81%
Sub-Total
5.00Carpentry and JoineryDiv 6, 9, 10
5.01Suspended Ceiling System (Magn. Board or Grid)43.40M20%
5.02PVC Ceiling System29.00M20%
5.03Nurse station Counter including door1.00Pcs0%
Sub-Total
6.00Roofing, Gutters & Misc. MetalsDiv 5, 7
6.01EGA-500 Roof Panels120.75M20%
6.02Fiberglass EGA Roof Panels12.48M20%
6.03Wire Mesh with Framing3.00M20%
6.04G-28 Flat Metal Flashing, Development Length 500mm35.00ML0%
6.05Splalash Trough along Roof Line using Water Proof Membrane10.00ML0%
6.06Splalash Trough along Roof Line U-drainTyp. Including grating10.00ML0%
6.07G-28 Flat Metal Roof Cap, Development Length 550mm12.60ML0%
Sub-Total
7.00Doors & WindowsDiv 6, 8, 12
7.01Door, Type D1, Wooden 120x280mm2.00Pcs0%
7.02Door, Type D3, Wooden 80x280mm1.00Pcs0%
7.03Door, Type D3A, Steel 80x280mm2.00Pcs0%
7.04Door, Type D4, Steel 160x280mm2.00Pcs0%
7.05Door, Type D6, Wooden 100x280mm2.00Pcs0%
7.06Door, Type D8, Wooden 100x200mm2.00Pcs0%
7.07Window, Type W1, 80x1807.00Pcs0%
7.08Window, Type W2, 80x704.00Pcs0%
7.09Window, Type W3, 100x1801.00Pcs0%
7.10Glazing17.48M20%
Sub-Total
8.00FinishingDiv 9
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar390.00M20%
8.03Internal Wall Surface, fine Coat plastering cement/sand381.60M20%
8.04External Wall Surface, fine Coat plastering cement/sand144.60m20%
8.05External HCB Wall Plastering, Two Coats Cement/Sand144.60M20%
8.06External HCB Wall Plastering, Slotted, Two Coats Cement/Sand5.60M20%
8.07Floor Mortar, Smooth 48mm thick for Plastic Tile38.32M20%
8.08Floor Mortar, Smooth 42mm thick for 8mm Ceramic Tile34.53M20%
8.09Floor Mortar, Smooth 40mm for 10mm Ceramic Tile25.48M20%
8.10PVC Floor Tiles38.32M20%
8.11PVC Skirting47.00ML0%
8.12Ceramic Floor Tiles, Non-slip, 8mm thickness34.53M20%
8.13Ceramic Floor Tiles, Non-slip, 10mm thickness25.48M20%
8.14Ceramic Tile Skirting72.40ML0%
8.15Ceramic Threshold, Door, 8mm Thickness9.40ML0%
8.16Terrazzo Window Sill, Chamfered with Drip Ledge9.80ML0%
8.17Plastic Emulsion Paint, three Coats on Internal Plaster296.08M20%
8.18Synthetic Enamel Paint, three Coats on Internal Plaster54.52M20%
8.19Plastic Emulsion Paint, three Coats on External Plaster144.60M20%
8.20Ceramic Wall Tile27.36M20%
8.21Broom-Finish on Concrete Slab9.00M20%
Sub-Total
9.00SpecialtiesDiv 10, 12, 15
9.01Signs, Type 17.00Pcs0%
9.02Signs, Type 23.00Pcs0%
9.03Signs, Type 31.00Pcs0%
9.04Signs, Type 41.00Pcs0%
9.05Toilet Accessory, Mirror2.00Pcs0%
9.06Toilet Accessory, Ceramic Soap Holder 185x95mm2.00Pcs0%
9.07Toilet Accessory, Stainless Steel Grab Bar, 32mmx 500mm2.00Pcs0%
9.08Toilet Accessory, Chrome Towel Rail2.00Pcs0%
9.09Fire Extinguisher, 6 Kg1.00Pcs0%
Sub-Total
10.00Sanitary FixturesDiv 10, 15
10.01Cast in-situ Handwash Basin with fittings2.00No0%
10.02Stainless Steel Handwash Basin with Fittings1.00No0%
10.03Shower Installation, Ceramic Tile Pan, Complete2.00No0%
10.04Electric Water Heater, 80 Liter with fittings (Not installed under PV Option)2.00No0%
10.05Janitor Trough, Ceramic Tile with Fittings1.00No0%
10.06Polypropylene (PPR-PN20) Water Pipe, 20mm4.00ML0%
10.07Polypropylene (PPR-PN20) Water Pipe, 25mm35.00ML0%
10.08Polypropylene (PPR-PN20) Water Pipe, 32mm4.00ML0%
10.09Stop Valves, 20mm10.00No0%
10.10uPVC Waste and Vent Pipe. 50mm20.00ML0%
10.11uPVC Waste and Vent Pipe. 80mm20.00ML72%
10.12uPVC Waste and Vent Pipe. 110mm18.00ML72%
10.13uPVC Vent Cap, 110mm1.00No0%
Sub-Total
11.00ElectricalDiv 16
11.01Flush mounted Distribution Board size 400x150x500mm, LPP-E, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 40A/3Phase ACB, 3 pcs 10A/1Phase MCBs, 1 pcs 16A/1Phase MCBs, 7 pcs 16A/1Phase GFCI MCBs.1.00No0%
11.02Electric Cable, Multi-Core Copper, PVC/PVC Coated, Color Coded in 50 mm diam PVC pipe, (5x6)mm sq. with Red warning tape35.00ML0%
11.03Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x2.5mm sq. inside PVC conduit of 16mm diameter, including junction boxes with covers and insulating screw cap connectors, complete25.00No0%
11.04Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x1.5mm sq. inside PVC conduit of 16mm diameter From Battery and Inverter Pack, including junction boxes with covers and insulating screw cap connectors, complete1.00No0%
11.05Light Switch Flush Mounted, Single Switch7.00No0%
11.06Light Switch Flush Mounted, Double Switch4.00No0%
11.07Light Switch Flush Mounted, Two-Way Switch2.00No0%
11.0816A/1Phase flush mounted socket outlet point fed through PVC insulated color coded copper conductors of 3x2.5mm sq. inside PVC conduit of 16mm diameter including junction boxes with covers and insulating screw cap connectors19.00No0%
11.09Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase12.00No0%
11.10Outlet Socket Flush Mounted, Earth Contact 10-16A/16A 1 Phase with cover4.00No0%
11.11Outlet Socket Flush Mounte Twin Socket, Earth Contact 10-16A/16A 1 Phase1.00No0%
11.12Outlet Socket Twin Flush Mounted, Earth Contact 10-16A/16A 1 Phase for Water Heater2.00No0%
11.13Light Fixtures, Type 212.00No0%
11.14Light Fixtures, Type 31.00No0%
11.15Light Fixtures, Type 49.00No0%
11.16Light Fixtures, Type 5.1, Feed From Battery Pack1.00No0%
11.17Light Fixtures, Type 72.00No0%
11.18Telephone/Data Outlet Box with (2) RJ 45 Connections1.00No0%
Sub-Total
Section Total

ID

Project:Debat,Site 22220-Aug-15
Bid SectionBid ItemDescriptionBill of Quantities
Spec. Div.QuantityUnit% complete
Section 1, Block F - Infectious Diseases
1.00Concrete Work, FoundationDiv 2, 3
1.01Structural Excavation12.02M30%
1.02Lean Concrete, 50 mm thickness5.42M30%
1.03Reinforced Concrete in Grade Beams, C-254.46M30%
1.04Reinforced Concrete in Floor Slab, C-256.65M30%
1.05Concrete formwork, Ground Contact34.54M20%
1.06Waterproofing Membrane, 0.2mm Poly Sheet74.22M20%
1.07Reinforcing Steel, 8mm Dia323.69kg0%
1.08Reinforcing Steel, 14mm Dia861.14kg0%
1.09Reinforcing Steel, 16mm Dia743.82kg0%
1.10Reinforcing Steel, 20mm Dia66.55kg0%
Sub-Total
2.00Concrete Work, StructureDiv. 3
2.01Reinforced Concrete in Columns, C-251.04M30%
2.02Reinforced Concrete in Roof Beams, C-253.07M30%
2.03Concrete(steel or timber) formwork for Columns20.80M20%
2.04Concrete(steel or timber) formwork for Roof Beams23.28M20%
2.05Reinforcing Steel, 8mm Dia157.12kg0%
2.06Reinforcing Steel, 12mm Dia362.41kg0%
2.07Reinforcing Steel, 14mm Dia471.43kg0%
Sub-Total
3.00Masonry WorkDiv 4, 9
3.01Hollow Core Concrete Block, Class B, 200mm thickness108.28M20%
3.02Hollow Core Concrete Block, Class B, 150mm thickness17.50M20%
3.03Hollow Core Concrete Block, Class B, 100mm thickness4.62M20%
3.04Terrazzo Wall Cap, 200mm Width10.10ML0%
Sub-Total
4.00Structural SteelDiv 5
The work Includes mortar adjustment.
TRUSS
4.01Cords, Girder Struts, Roof Post, SHS 30x2mm119.88Kg0%
4.02Brace, Girder struts, SHS 25x2mm22.39Kg0%
PURLIN
4.03Roof Purlin, RHS 80x40x2mm142.40Kg0%
4.04Roof Purlin, RHS 80x40x2.5mm131.70Kg0%
PLATES
4.05Steel Plates, 2xFL 60x42-55x5mm4.00Pcs0%
4.06Steel Plates, 2xFL 140x42-72x5mm4.00Pcs0%
4.07Steel Plates, 2xFL 150x120x5mm56.00Pcs0%
4.08Steel Plates, 2xFL 60x57x5mm4.00Pcs0%
4.09Steel Plates, FL 180x150x10mm4.00Pcs0%
4.10Steel Plates, FL 150x70x10mm8.00Pcs0%
4.11Steel Plates, FL 180x65x10mm8.00Pcs0%
4.12Steel Plates, FL 100x36x5mm20.00Pcs0%
4.13Steel Plates, FL 100x55x5mm16.00Pcs0%
4.14Steel Plates, FL 110x32x5mm16.00Pcs0%
4.15Steel End Plate, FL 21x21x2mm20.00Pcs0%
4.16Steel End Plate, FL 26x26x2mm4.00Pcs0%
4.17Steel End Plate, FL 36x76x2mm28.00Pcs0%
BOLTS & ANCHORAGES
4.18M12 bolts104.00Pcs0%
Sub-Total
5.00Carpentry and JoineryDiv 6, 9, 10
5.01Suspended Ceiling System (Magn. Board or Grid)25.20M20%
Sub-Total
6.00Roofing, Gutters & Misc. MetalsDiv 5, 7
6.01EGA-500 Roof Panels66.04M20%
6.02Wire Mesh with Framing1.44M20%
6.03G-28 Flat Metal Flashing, Development Length 500mm24.80ML0%
6.04Splalash Trough along Roof Line using Water Proof Membrane10.00ML0%
6.05G-28 Flat Metal Roof Cap, Development Length 550mm5.00ML0%
Sub-Total
7.00Doors & WindowsDiv 6, 8, 12
7.01Door, Type D2, Wooden 90x280mm1.00Pcs0%
7.02Door, Type D3, Wooden 80x280mm1.00Pcs0%
7.03Door, Type D3A, Steel 80x280mm1.00Pcs0%
7.04Window, Type W1, 80x1804.00Pcs0%
7.05Window, Type W2, 80x702.00Pcs0%
7.06Glazing7.44M20%
Sub-Total
8.00FinishingDiv 9
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar117.44M20%
8.02Internal Wall Surface, fine Coat plastering cement/sand117.44M20%
8.03External Wall Surface, fine Coat plastering cement/sand72.60m20%
8.04External HCB Wall Plastering, Two Coats Cement/Sand72.60M20%
8.05External HCB Wall Plastering, Slotted, Two Coats Cement/Sand3.20M20%
8.06Floor Mortar, Smooth 48mm thick for Plastic TileM20%
8.07Floor Mortar, Smooth 42mm thick for 8mm Ceramic Tile27.00M20%
8.08Ceramic Floor Tiles, Non-slip, 8mm thickness27.00M20%
8.09Ceramic Tile Skirting30.00ML0%
8.10Ceramic Threshold, Door, 8mm Thickness2.65ML0%
8.11Terrazzo Window Sill, Chamfered with Drip Ledge4.80ML0%
8.12Plastic Emulsion Paint, three Coats on Internal Plaster91.70M20%
8.13Synthetic Enamel Paint, three Coats on Internal Plaster22.10M20%
8.14Plastic Emulsion Paint, three Coats on External Plaster72.60M20%
8.15Floor Mortar, Smooth 20 mm thick for terrazzo Tile22.50M20%
8.16Terrazzo tile flooring22.50M20%
8.17Terrazzo tile Skirting11.75Ml0%
Sub-Total
9.00SpecialtiesDiv 10, 12, 15
9.01Signs, Type 12.00Pcs0%
9.02Signs, Type 26.00Pcs0%
9.03Signs, Type 32.00Pcs0%
9.04Signs, Type 41.00Pcs0%
9.05Fire Extinguisher, 6 Kg1.00Pcs0%
9.06Steel framed Wooden Benches Type A7.00Pcs0%
Sub-Total
10.00Sanitary FixturesDiv 10, 15
10.01Stainless Steel Handwash Basin with fittings1.00Pcs0%
10.02Polypropylene (PPR-PN20) Water Pipe, 20mm2.00ML0%
10.03Polypropylene (PPR-PN20) Water Pipe, 25mm6.00ML0%
10.04Stop Valves, 20mm1.00No0%
10.05uPVC Waste and Vent Pipe. 50mm6.00ML0%
10.06uPVC Waste and Vent Pipe. 80mm2.00ML0%
10.07uPVC Waste and Vent Pipe. 110mm4.00ML0%
10.08uPVC Vent Cap, 110mm1.00No0%
Sub-Total
11.00ElectricalDiv 16
11.01Flush mounted Distribution Board size 400x125x200mm, LPP-F, with lockable door and including all necessary fixing and connecting accessories, complete and consisting of 1 pc main 20A/1Phase ACB, 2 pcs 10A/1Phase MCBs, 1 pcs 16A/1Phase MCB, 2 pcs 16A/1Phase GFCI MCBs.1.00No0%
11.02Electric Cable, Multi-Core Copper, PVC/PVC, Color Coded in 50mm diam PVC pipe, (3x4)mm sq. with Red warning tape65.00ML0%
11.03Flush mounted light point, fed through PVC insulated color coded copper conductor of 3x2.5mm sq. inside PVC conduit of 16mm diameter, including junction boxes with covers and insulating screw cap connectors, complete6.00No0%
11.04Light Switch Flush Mounted, Single Switch1.00No0%
11.05Light Switch Flush Mounted, Double Switch1.00No0%
11.06Light Switch Flush Mounted, Two-Way Switch2.00No0%
11.07Socket Point Flush Mtd, 10-16A/1 phase PVC Coated Copper, 3x2.5mm sq in 16mm diameter Conduit including junction boxes with cover and insulating screw cap connectors, complete6.00No0%
11.08Outlet Socket Flush Mounted, Earth Contact 16A 1 Phase4.00No0%
11.09Outlet Socket Flush Mounted, Earth Contact 16A 1 Phase with cover1.00No0%
11.10Outlet Socket Flush Mounte Twin Socket, Earth Contact 16A 1 Phase1.00No0%
11.11Light Fixtures, Type 21.00No0%
11.12Light Fixtures, Type 45.00No0%
11.13Telephone/Data Outlet Box with (2) RJ 45 Connections1.00No0%
Sub-Total
Section Total

PitLatr

Project:Debat,Site 22220-Aug-15