J-3-4,_09-NEV-E.pdf
PDF 5 MB Posted
- Attached to
- Operational Rooms, Colombia Federal contract opportunity
- Solicitation number
- SAQMMA17R0127
About this file
Attach. J-3-4, 09
View the file
Other files for this federal contract opportunity
Show all 38
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UBICACION
CONTENEDOR
UBICACION 1
ESPACIO VARIABLE
ACOMETIDA
ELECTRICA 150m
PUNTO ELECTRICO
TRANSFORMADOR DE 75kVA
1 2 3 4 5 6
E
D
C
B
A
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
NOTICE:
THIS DOCUMENT IS THE PROPERTY OF
THE U.S. GOVERNMENT. FURTHER
REPRODUCTION AND/OR DISTRIBUTION IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT
SECTION, BOGOTA, COLOMBIA.
INFORMATION ON THIS DOCUMENT IS NOT
TO BE ALTERED EXCEPT WITH THE
WRITTEN APPROVAL OF THE OFFICE.
MANAGED BY:
I.N.L
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
SHEET No:
A & E DESIGN FIRM:
DIAZ VILLEGAS ARQUITECTOS
www.diazvillegasarquitectos.com
TELEFONO: 6262659 - 7042265
PROJECT:
LOCATION:
CONTRACT NUMBER:
COR VO.Bo.:
OF:
REVIEW:PLAN No:
CONTENIDO:
LEGEND:
REVIEWS:
PHASE:
10% 35% 60% 90% 100%
DRAWING DATE:
SIGNATURE:
PROFFESIONAL CARD:
PROFFESION:
LIFETED BY:
CONTENTS:
No. SUBMITTAL DATE
CONTRACT DATE:
SCALE:
OBSERVATIONS:
SHEET PLAN:
SHEET No:
OF:
REVIEW: PLAN No:
A&E OPERATIONAL CENTER FITOUT,
12 CITIES FOR THE COLOMBIAN
NATIONAL POLICE
SCO150-16-M-0313
OCT 03 / 2016
205-12713 CND
Electrical Engineer
Ing. Julio Cesar Garcia V.
UE-001
UE-001
1 : 100
087.08-NEIVA-EEC-101.dwg
SCALE
ESCALA
GENERAL WIRING DETAIL
1:100
DETALLE ACOMETIDA GENERAL
1:100
A1
DETALLE DE ACOMETIDA GENERAL
GENERAL WIRING DETAIL
AutoCAD SHX Text
ACOMETIDA GENERAL PARA ALIMENTACIONDE SALA DE CRISIS
AutoCAD SHX Text 60x60
AutoCAD SHX Text 60x60
AutoCAD SHX Text 60x60
AutoCAD SHX Text
EXISTING SUBSTATION
AutoCAD SHX Text
SUBESTACION EXISTENTE
AutoCAD SHX Text Y
AutoCAD SHX Text
CONTAINER
AutoCAD SHX Text
REPLACE EXISTING SUBSTATION (75KVA) FOR 112.5KVA
AutoCAD SHX Text
REEMPLAZAR SUBESTACION EXISTENTE (75KVA) POR UNA DE 112.5KVA
AutoCAD SHX Text
AutoCAD SHX Text 1ø3" PVC
AutoCAD SHX Text 2ø3" PVC
AutoCAD SHX Text 2ø3" PVC
AutoCAD SHX Text
GENERAL WIRING FOR ROOM CRISIS
A
B
A'
2 3 4 5
1 2 3 4 5 6
E
D
C
B
A
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
NOTICE:
THIS DOCUMENT IS THE PROPERTY OF
THE U.S. GOVERNMENT. FURTHER
REPRODUCTION AND/OR DISTRIBUTION IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT
SECTION, BOGOTA, COLOMBIA.
INFORMATION ON THIS DOCUMENT IS NOT
TO BE ALTERED EXCEPT WITH THE
WRITTEN APPROVAL OF THE OFFICE.
MANAGED BY:
I.N.L
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
SHEET No:
A & E DESIGN FIRM:
DIAZ VILLEGAS ARQUITECTOS
www.diazvillegasarquitectos.com
TELEFONO: 6262659 - 7042265
PROJECT:
LOCATION:
CONTRACT NUMBER:
COR VO.Bo.:
OF:
REVIEW:PLAN No:
CONTENIDO:
LEGEND:
REVIEWS:
PHASE:
10% 35% 60% 90% 100%
DRAWING DATE:
SIGNATURE:
PROFFESIONAL CARD:
PROFFESION:
LIFETED BY:
CONTENTS:
No. SUBMITTAL DATE
CONTRACT DATE:
SCALE:
OBSERVATIONS:
SHEET PLAN:
SHEET No:
OF:
REVIEW: PLAN No:
A&E OPERATIONAL CENTER FITOUT,
12 CITIES FOR THE COLOMBIAN
NATIONAL POLICE
SCO150-16-M-0313
OCT 03 / 2016
205-12713 CND
Electrical Engineer
Ing. Julio Cesar Garcia V.
ETC-101
DISEÑO TOMACORRIENTES
ETC-101
1 : 25
087.08-NEIVA-ETC-101.dwg
OUTLETS DESIGN
SCALE
ESCALA
OUTLETS DESIGN
1:25
DISEÑO TOMACORRIENTES
1:25
A1
AutoCAD SHX Text
(OPERARIOS)
AutoCAD SHX Text
OPERATORS
AutoCAD SHX Text
(RACK'S+UPS)
AutoCAD SHX Text
RACK'S+UPS
AutoCAD SHX Text
ACCESO PRINCIPAL
AutoCAD SHX Text
PRINCIPAL ACCES
AutoCAD SHX Text
(SALA DE REUNIONES)
AutoCAD SHX Text
MEETING ROOM
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text ø1"-1#2T Desnudo
AutoCAD SHX Text 15x15
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text Cw 5/8"x8' '
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text Cw 5/8"x8' '
AutoCAD SHX Text Cw 5/8"x8' '
AutoCAD SHX Text Cw 5/8"x8' '
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text T /T T 2/0 Cu
AutoCAD SHX Text
AutoCAD SHX Text ø3/4"-4#12+12T
AutoCAD SHX Text Pozo de inspección Malla de Puesta a Tierra
AutoCAD SHX Text ø3/4"-4#12+12T
AutoCAD SHX Text Malla de puesta a tierra 5x5m con 4 varillas Cu 5/8" 2.4m
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Ground bus bar
AutoCAD SHX Text Barraje de Tierras
AutoCAD SHX Text Ground mesh of 5x5m con 4 copper Cu 5/8" 2.4m
AutoCAD SHX Text
4. AISLAMIENTO Y TIPO DE LOS CONDUCTORES
AutoCAD SHX Text
CONDUCTOR DE TIERRA
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
AISLAMIENTO
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
NOTAS:
AutoCAD SHX Text
CALIBRE
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
TOMACORRIENTES
AutoCAD SHX Text
ALUMBRADO
AutoCAD SHX Text
PARTE DEL SISTEMA
AutoCAD SHX Text
ALIMENTADORES
AutoCAD SHX Text
SEGUN DIAGR.
AutoCAD SHX Text
CALIBRE MINIMO
AutoCAD SHX Text
TIPO DE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
SI
AutoCAD SHX Text
UNIFILAR
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTO TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTODONDE SE ESPECIFIQUE. 2. LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA NTC 979, DE LO CONTRARIO SERÁ TIPO EMT. 3. TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR DE TIERRA ASÍ:
AutoCAD SHX Text
* SOLO SI NO QUEDA COBIJADO POR LA RESOLUCIÓN MINMINAS 90708 DE 2013 NUMERAL 20.2.9 G) SE PODRÁ UTILIZAR CABLEADO CON AISLAMIENTO THHN-THWN. LLAMADO DE ATENCIÓN QUE INDICA SUBE Y/O BAJA SEGÚN ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE BAJA 1ø3/4" Y PASA 1 3/4" POR CADA UNA DE LAS CUENTAS DE LOS PISOS SUPERIORESSEGÚN INDICA EL ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE ESTA TOMACORRIENTE ES ESCLAVA DE OTRA TOMACORRIENTE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
4. INSULATING AND CONDUCTORS TYPE
AutoCAD SHX Text
GROUNDING CONDUTOR
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
INSULATING
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
CALINER
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
SOCKETS
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
SYSTEM PART
AutoCAD SHX Text
SUPPLIERS
AutoCAD SHX Text
ACCORDING TO SINGLE
AutoCAD SHX Text
MINIMUM CALIBER
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
LINE DIAGRAM
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. ALL PIPING SHALL BE 1/2" AND THE CONDUCT No.12 AWG EXCEPT ALL PIPING SHALL BE 1/2" AND THE CONDUCT No.12 AWG EXCEPTWHERE IT IS SPECIFIED. 2. ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO NTC 979 REGULATION, OTHERWISE IT SHALL BE EMT. 3. ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A GROUNDING CONDUTOR AS FOLLOWS:
AutoCAD SHX Text
* ONLY IF NOT COVERED BY THE MINIMUM RESOLUTION 90708 OF 2013 NUMERAL 20.2.9 G) THHN-THWN. INSULATION COULD BE USED WARNING SIGN INDICATES THAT GOES UP OR DOWN ACCORDING TO VERTICAL DIAGRAM. WARNING SIGN INDICATES THAT GOES DOWN 1ø3/4" AND GOES THROUGH 1 3/4" EACH OF THE SUPERIOR FLOOR COUNTS ACCORDINGTO VERTICAL DIAGRAM. WARNING TO INDICATE THAT THIS OUTLET IS SLAVED TO ANOTHER OUTLET.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
T-GENERAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
T-GENERAL
AutoCAD SHX Text
AutoCAD SHX Text
T-REGULATED
AutoCAD SHX Text
T-REGULADO
AutoCAD SHX Text
T-UTILITY (LIGHTING AND OUTLETS)
AutoCAD SHX Text
T-USO GENERAL (ALUMBRADO Y TOMAS)
AutoCAD SHX Text
T-AIRE (18 CIRCUITOS)
AutoCAD SHX Text
T-AIR (18 CIRCUITS)
AutoCAD SHX Text Llamado de atención para explicar que: El videowall se compone de 6 monitores c/u de 55 pulgadas, cada monitor tendra una tomacorriente doble que sirve al monitor y su respectivo amplificador de señal, de tal forma que en la indicación actual de cada toma se dejaran tres tomas (Altura 1.2m. 1.8m). La alimentación eléctrica del Rack, se compone de 6 circuitos regulados c/u cableado en 2#12+12T Cable aislado.
AutoCAD SHX Text
CIRCUITO REGULADO
AutoCAD SHX Text
EQUIPO
AutoCAD SHX Text
AutoCAD SHX Text Amplificador audio (600 VA) + Grabación CCTV (700 VA)
AutoCAD SHX Text
AutoCAD SHX Text Servidor (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Servidor (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Control de Video (700 VA) + KRM (500 VA)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text = ElectroimánElectroimán
AutoCAD SHX Text Warning sign to explain: Videowall is composed by 6 monitors, 55" each. Each monitor will have a double receptacle which connect the monitor and its signal amplifier, in such way that in the actual receptacle indication, three receptacles will be left. (Height 1.2m. 1.8m). Rack power feeding is composed by 6 regulated circuits, each one 2#12+12T wired with isolated copper.
AutoCAD SHX Text
REGULATED CIRCUIT
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
AutoCAD SHX Text Audio Amplifier (600 VA) + CCTV Recording (700 VA)
AutoCAD SHX Text
AutoCAD SHX Text Server (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Server (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Control de Video (700 VA) + KRM (500 VA)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text I
= ElectroimánElectroimán
B
A'
2 3 4 5
1 2 3 4 5 6
E
D
C
B
A
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
NOTICE:
THIS DOCUMENT IS THE PROPERTY OF
THE U.S. GOVERNMENT. FURTHER
REPRODUCTION AND/OR DISTRIBUTION IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT
SECTION, BOGOTA, COLOMBIA.
INFORMATION ON THIS DOCUMENT IS NOT
TO BE ALTERED EXCEPT WITH THE
WRITTEN APPROVAL OF THE OFFICE.
MANAGED BY:
I.N.L
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
SHEET No:
A & E DESIGN FIRM:
DIAZ VILLEGAS ARQUITECTOS
www.diazvillegasarquitectos.com
TELEFONO: 6262659 - 7042265
PROJECT:
LOCATION:
CONTRACT NUMBER:
COR VO.Bo.:
OF:
REVIEW:PLAN No:
CONTENIDO:
LEGEND:
REVIEWS:
PHASE:
10% 35% 60% 90% 100%
DRAWING DATE:
SIGNATURE:
PROFFESIONAL CARD:
PROFFESION:
LIFETED BY:
CONTENTS:
No. SUBMITTAL DATE
CONTRACT DATE:
SCALE:
OBSERVATIONS:
SHEET PLAN:
SHEET No:
OF:
REVIEW: PLAN No:
A&E OPERATIONAL CENTER FITOUT,
12 CITIES FOR THE COLOMBIAN
NATIONAL POLICE
SCO150-16-M-0313
OCT 03 / 2016
205-12713 CND
Electrical Engineer
Ing. Julio Cesar Garcia V.
ETR-102
DISEÑO TOMACORRIENTES REGULADAS
ETR-102
1 : 25
087.08-NEIVA-ETR-102.dwg
REGULATED OUTLETS DESIGN
SCALE
ESCALA
REGULATED OUTLETS DESIGN
1:25
DISEÑO TOMACORRIENTES REGULADAS
1:25
A1
AutoCAD SHX Text
(OPERARIOS)
AutoCAD SHX Text
OPERATORS
AutoCAD SHX Text
(RACK'S+UPS)
AutoCAD SHX Text
RACK'S+UPS
AutoCAD SHX Text
ACCESO PRINCIPAL
AutoCAD SHX Text
PRINCIPAL ACCES
AutoCAD SHX Text
(SALA DE REUNIONES)
AutoCAD SHX Text
MEETING ROOM
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text 7R
AutoCAD SHX Text 7R
AutoCAD SHX Text 7R
AutoCAD SHX Text 7R
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text 10R
AutoCAD SHX Text 9R
AutoCAD SHX Text 9R
AutoCAD SHX Text 9R
AutoCAD SHX Text 2#12+12T
AutoCAD SHX Text 2(2#12+12T)
AutoCAD SHX Text 10R
AutoCAD SHX Text 10R
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UPS
AutoCAD SHX Text 2ø1½"½""
AutoCAD SHX Text
AutoCAD SHX Text 2ø1"-c/u-3(2#12+12T) Cir. 1-2-3 y 4-5-6R
AutoCAD SHX Text
20 KVA
AutoCAD SHX Text 17R
AutoCAD SHX Text c/uø1½"- ½"- "- c/u3#4+2+4T
AutoCAD SHX Text
AutoCAD SHX Text 1ø1½"½""
AutoCAD SHX Text 1ø1¼"¼""
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text I
AutoCAD SHX Text 17R
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text 8R
AutoCAD SHX Text 8R
AutoCAD SHX Text 8R
AutoCAD SHX Text 8R
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2(2#12+12T)
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text 12R
AutoCAD SHX Text 11R
AutoCAD SHX Text 11R
AutoCAD SHX Text 11R
AutoCAD SHX Text 11R
AutoCAD SHX Text 12R
AutoCAD SHX Text 12R
AutoCAD SHX Text 12R
AutoCAD SHX Text 17R
AutoCAD SHX Text I
AutoCAD SHX Text 17R
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text 3ø3/4"c/u-2(2#12+12T) ø1"-3(2#12+12)
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø1"-3(2#12+12)
AutoCAD SHX Text ø3/4"-2(2#12+12T)
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text 17R
AutoCAD SHX Text ø3/4"-2(2#12+12T) ø3/4"-2#12+12T
AutoCAD SHX Text R
AutoCAD SHX Text 15R
AutoCAD SHX Text R
AutoCAD SHX Text 13R
AutoCAD SHX Text R
AutoCAD SHX Text 14R
AutoCAD SHX Text x2
AutoCAD SHX Text x2
AutoCAD SHX Text x3
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text ø3/4"-2#12+12T
AutoCAD SHX Text 2ø3/4"-c/u 2#12+12T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
200 V.A CONTROL ACCESS
AutoCAD SHX Text
200 V.A CONTROLADOR DE ACCESO
AutoCAD SHX Text
VIDEOCONFERENCE CAMERA
AutoCAD SHX Text
CÁMARAS VIDEOCONFERENCIA
AutoCAD SHX Text
4. AISLAMIENTO Y TIPO DE LOS CONDUCTORES
AutoCAD SHX Text
CONDUCTOR DE TIERRA
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
AISLAMIENTO
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
NOTAS:
AutoCAD SHX Text
CALIBRE
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
TOMACORRIENTES
AutoCAD SHX Text
ALUMBRADO
AutoCAD SHX Text
PARTE DEL SISTEMA
AutoCAD SHX Text
ALIMENTADORES
AutoCAD SHX Text
SEGUN DIAGR.
AutoCAD SHX Text
CALIBRE MINIMO
AutoCAD SHX Text
TIPO DE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
SI
AutoCAD SHX Text
UNIFILAR
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTO TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTODONDE SE ESPECIFIQUE. 2. LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA NTC 979, DE LO CONTRARIO SERÁ TIPO EMT. 3. TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR DE TIERRA ASÍ:
AutoCAD SHX Text
* SOLO SI NO QUEDA COBIJADO POR LA RESOLUCIÓN MINMINAS 90708 DE 2013 NUMERAL 20.2.9 G) SE PODRÁ UTILIZAR CABLEADO CON AISLAMIENTO THHN-THWN. LLAMADO DE ATENCIÓN QUE INDICA SUBE Y/O BAJA SEGÚN ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE BAJA 1ø3/4" Y PASA 1 3/4" POR CADA UNA DE LAS CUENTAS DE LOS PISOS SUPERIORESSEGÚN INDICA EL ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE ESTA TOMACORRIENTE ES ESCLAVA DE OTRA TOMACORRIENTE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
4. INSULATING AND CONDUCTORS TYPE
AutoCAD SHX Text
GROUNDING CONDUTOR
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
INSULATING
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
CALINER
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
SOCKETS
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
SYSTEM PART
AutoCAD SHX Text
SUPPLIERS
AutoCAD SHX Text
ACCORDING TO SINGLE
AutoCAD SHX Text
MINIMUM CALIBER
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
LINE DIAGRAM
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. ALL PIPING SHALL BE 1/2" AND THE CONDUCT No.12 AWG EXCEPT ALL PIPING SHALL BE 1/2" AND THE CONDUCT No.12 AWG EXCEPTWHERE IT IS SPECIFIED. 2. ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO NTC 979 REGULATION, OTHERWISE IT SHALL BE EMT. 3. ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A GROUNDING CONDUTOR AS FOLLOWS:
AutoCAD SHX Text
* ONLY IF NOT COVERED BY THE MINIMUM RESOLUTION 90708 OF 2013 NUMERAL 20.2.9 G) THHN-THWN. INSULATION COULD BE USED WARNING SIGN INDICATES THAT GOES UP OR DOWN ACCORDING TO VERTICAL DIAGRAM. WARNING SIGN INDICATES THAT GOES DOWN 1ø3/4" AND GOES THROUGH 1 3/4" EACH OF THE SUPERIOR FLOOR COUNTS ACCORDINGTO VERTICAL DIAGRAM. WARNING TO INDICATE THAT THIS OUTLET IS SLAVED TO ANOTHER OUTLET.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
T-GENERAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
T-GENERAL
AutoCAD SHX Text
AutoCAD SHX Text
T-REGULATED
AutoCAD SHX Text
T-REGULADO
AutoCAD SHX Text
T-UTILITY (LIGHTING AND OUTLETS)
AutoCAD SHX Text
T-USO GENERAL (ALUMBRADO Y TOMAS)
AutoCAD SHX Text
T-AIRE (18 CIRCUITOS)
AutoCAD SHX Text
T-AIR (18 CIRCUITS)
AutoCAD SHX Text Llamado de atención para explicar que: El videowall se compone de 6 monitores c/u de 55 pulgadas, cada monitor tendra una tomacorriente doble que sirve al monitor y su respectivo amplificador de señal, de tal forma que en la indicación actual de cada toma se dejaran tres tomas (Altura 1.2m. 1.8m). La alimentación eléctrica del Rack, se compone de 6 circuitos regulados c/u cableado en 2#12+12T Cable aislado.
AutoCAD SHX Text
CIRCUITO REGULADO
AutoCAD SHX Text
EQUIPO
AutoCAD SHX Text
AutoCAD SHX Text Amplificador audio (600 VA) + Grabación CCTV (700 VA)
AutoCAD SHX Text
AutoCAD SHX Text Servidor (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Servidor (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Control de Video (700 VA) + KRM (500 VA)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text = ElectroimánElectroimán
AutoCAD SHX Text Warning sign to explain: Videowall is composed by 6 monitors, 55" each. Each monitor will have a double receptacle which connect the monitor and its signal amplifier, in such way that in the actual receptacle indication, three receptacles will be left. (Height 1.2m. 1.8m). Rack power feeding is composed by 6 regulated circuits, each one 2#12+12T wired with isolated copper.
AutoCAD SHX Text
REGULATED CIRCUIT
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
AutoCAD SHX Text Audio Amplifier (600 VA) + CCTV Recording (700 VA)
AutoCAD SHX Text
AutoCAD SHX Text Server (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Server (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Control de Video (700 VA) + KRM (500 VA)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text I
= ElectroimánElectroimán
B
A'
2 3 4 5
1 2 3 4 5 6
E
D
C
B
A
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
NOTICE:
THIS DOCUMENT IS THE PROPERTY OF
THE U.S. GOVERNMENT. FURTHER
REPRODUCTION AND/OR DISTRIBUTION IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT
SECTION, BOGOTA, COLOMBIA.
INFORMATION ON THIS DOCUMENT IS NOT
TO BE ALTERED EXCEPT WITH THE
WRITTEN APPROVAL OF THE OFFICE.
MANAGED BY:
I.N.L
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
SHEET No:
A & E DESIGN FIRM:
DIAZ VILLEGAS ARQUITECTOS
www.diazvillegasarquitectos.com
TELEFONO: 6262659 - 7042265
PROJECT:
LOCATION:
CONTRACT NUMBER:
COR VO.Bo.:
OF:
REVIEW:PLAN No:
CONTENIDO:
LEGEND:
REVIEWS:
PHASE:
10% 35% 60% 90% 100%
DRAWING DATE:
SIGNATURE:
PROFFESIONAL CARD:
PROFFESION:
LIFETED BY:
CONTENTS:
No. SUBMITTAL DATE
CONTRACT DATE:
SCALE:
OBSERVATIONS:
SHEET PLAN:
SHEET No:
OF:
REVIEW: PLAN No:
A&E OPERATIONAL CENTER FITOUT,
12 CITIES FOR THE COLOMBIAN
NATIONAL POLICE
SCO150-16-M-0313
OCT 03 / 2016
205-12713 CND
Electrical Engineer
Ing. Julio Cesar Garcia V.
EIL-101
DISEÑO DE ILUMINACION
EIL-101
1 : 25
087.08-NEIVA-EIL-101.dwg
LIGHTING DESIGN
SCALE
ESCALA
LIGHTING DESIGN
1:25
DISEÑO ILUMINACION
1:25
A1
AutoCAD SHX Text
(OPERARIOS)
AutoCAD SHX Text
OPERATORS
AutoCAD SHX Text
(RACK'S+UPS)
AutoCAD SHX Text
RACK'S+UPS
AutoCAD SHX Text
ACCESO PRINCIPAL
AutoCAD SHX Text
PRINCIPAL ACCES
AutoCAD SHX Text
(SALA DE REUNIONES)
AutoCAD SHX Text
MEETING ROOM
AutoCAD SHX Text A'
AutoCAD SHX Text U
AutoCAD SHX Text U
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text V
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
LBE
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text ø3/4"-6#12+12T
AutoCAD SHX Text
CI
AutoCAD SHX Text ø1"-6#12+12T
AutoCAD SHX Text
AutoCAD SHX Text ø3/4"
AutoCAD SHX Text
AutoCAD SHX Text 12E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text a control iluminación
AutoCAD SHX Text 2ø3/4"
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
LBE
AutoCAD SHX Text 12E
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text Cir.9-10-11
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
LBE
AutoCAD SHX Text 12E
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text a control iluminación
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
LBE
AutoCAD SHX Text 12E
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text Cinta Led
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text 2x16
AutoCAD SHX Text 2x16
AutoCAD SHX Text Cinta Led
AutoCAD SHX Text Led Tape
AutoCAD SHX Text Atenuable
AutoCAD SHX Text Dimmable
AutoCAD SHX Text Lighting Control
AutoCAD SHX Text Atenuable
AutoCAD SHX Text Dimmable
AutoCAD SHX Text Atenuable
AutoCAD SHX Text Dimmable
AutoCAD SHX Text Cinta Led
AutoCAD SHX Text Led Tape
AutoCAD SHX Text a control iluminación
AutoCAD SHX Text Lighting Control
AutoCAD SHX Text Led Tape
AutoCAD SHX Text Lighting Control
AutoCAD SHX Text Solo emergencia
AutoCAD SHX Text Emergency Only
AutoCAD SHX Text Cinta Led
AutoCAD SHX Text Led Tape
AutoCAD SHX Text G
AutoCAD SHX Text
(LAMPARA TENSOFLEX 3D)
AutoCAD SHX Text
TENSOFLEX LAMP 3D
AutoCAD SHX Text Llamado de atencion para explicar: La caja de control de luces, se compondrá de interrutor de 15amp, 5 on-off, adicionalmente con dimmer y un control inteligente para la cinta led (RGB). Este tubo de ø3/4" permitirá servir el control de iluminación de la cinta led del perímetro de la sala de crisis. Los plafones luminarias ubicadas encima de la mesa central serán atenuables desde la caja de control de luces.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Warning sign to explain: The control box lights, be composed of switch 15amp, 6 on-off, additionally with dimmer and intelligent control for the tape led (RGB). This tube ø3/4" allowed to serve lighting control tape led the perimeter of the room crisis. The ceiling lights located above the central table are dimmable from the control box lights.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text U
AutoCAD SHX Text
(BALA MOON RS + LED 10.4W APERTURA 36°)
AutoCAD SHX Text
BULLET MOON RS + LED 10.4W OPENING 36°
AutoCAD SHX Text V
AutoCAD SHX Text
(LAMPARA HERMETICA LED TCI 2X25W)
AutoCAD SHX Text
HERMETIC LED LAMP TCI 2X25W
AutoCAD SHX Text A'
AutoCAD SHX Text
(LUMINARIA LINEAL LED FLEX STRIP BLANCO)
AutoCAD SHX Text
LINEAR LUMINAIRE WHITE LED FLEX STRIP
AutoCAD SHX Text X
AutoCAD SHX Text
(LUMINARIA LINEAL LED FLEX STRIP AZUL)
AutoCAD SHX Text
LINEAR LUMINAIRE BLUE LED FLEX STRIP
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text
SALIDA PARA BALA LED
AutoCAD SHX Text
PROYECTOR (EN EXTERIORES )
AutoCAD SHX Text
TOMA SENCILLA
AutoCAD SHX Text
TOMA EN PISO
AutoCAD SHX Text
TOMA UTENSILIOS
AutoCAD SHX Text
TOMA NEVERA
AutoCAD SHX Text
CAJA DE PASO DE 10X10
AutoCAD SHX Text
CONVENCIONES ELECTRICAS
AutoCAD SHX Text
BLOQUE
AutoCAD SHX Text
DESCRIPCIÓN
AutoCAD SHX Text
LÁMPARA LINEAL LED
AutoCAD SHX Text S
AutoCAD SHX Text
INTERRUPTOR
AutoCAD SHX Text
TABLEROS
AutoCAD SHX Text
SALIDA PARA ROSETA
AutoCAD SHX Text
DETECTOR DE PRESENCIA
AutoCAD SHX Text
DP
AutoCAD SHX Text
TUBO POR PISO
AutoCAD SHX Text
INTERRUMPIDO
AutoCAD SHX Text G
AutoCAD SHX Text
TOMA G.F.C.I.
AutoCAD SHX Text
SALIDA DE DATOS
AutoCAD SHX Text D
AutoCAD SHX Text
LÁMPARA BATERÍA DE EMERGENCIA
AutoCAD SHX Text
LBE
AutoCAD SHX Text
BLOQUE
AutoCAD SHX Text
DESCRIPCIÓN
AutoCAD SHX Text
LLAMADO DE ATENCIÓN
AutoCAD SHX Text
CONDUCTOR DE TIERRA
AutoCAD SHX Text
NOTAS:
AutoCAD SHX Text
TOMACORRIENTES
AutoCAD SHX Text
ALUMBRADO
AutoCAD SHX Text
PARTE DEL SISTEMA
AutoCAD SHX Text
ALIMENTADORES
AutoCAD SHX Text
SEGUN DIAGR.
AutoCAD SHX Text
CALIBRE MINIMO
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
SI
AutoCAD SHX Text
UNIFILAR
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
1. TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTO DONDE SE TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTO DONDE SEESPECIFIQUE. 2. LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA NTC LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA NTC 979, DE LO CONTRARIO SERÁ TIPO EMT. 3. TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR DE TIERRA ASÍ:
AutoCAD SHX Text
4. AISLAMIENTO Y TIPO DE LOS CONDUCTORES
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
AISLAMIENTO
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
CALIBRE
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
TIPO DE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
AutoCAD SHX Text
* SOLO SI NO QUEDA COBIJADO POR LA RESOLUCIÓN MINMINAS 90708 DE 2013 NUMERAL 20.2.9 G) SE PODRÁ UTILIZAR CABLEADO CON AISLAMIENTO THHN-THWN. LLAMADO DE ATENCIÓN QUE INDICA SUBE Y/O BAJA SEGÚN ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE BAJA 1ø3/4" Y PASA 1 3/4" POR CADA UNA DE LAS CUENTAS DE LOS PISOS SUPERIORESSEGÚN INDICA EL ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE ESTA TOMACORRIENTE ES ESCLAVA DE OTRA TOMACORRIENTE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text
OUTLET FOR BULLET LED LIGHTING FIXTURE
AutoCAD SHX Text
PROJECTOR (OUTDOORS)
AutoCAD SHX Text
SINGLE RECEPTACLE
AutoCAD SHX Text
FLOOR RECEPTACLE
AutoCAD SHX Text
APPLIANCES RECEPTACLE
AutoCAD SHX Text
REFRIGERATOR RECEPTACLE
AutoCAD SHX Text
PASSING BOX 10X10
AutoCAD SHX Text
ELECTRIC LEGEND
AutoCAD SHX Text
BLOCK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
LED LINEAL LUMINAIRE
AutoCAD SHX Text S
AutoCAD SHX Text
SINGLE SWITCH
AutoCAD SHX Text
PANELBOARDS
AutoCAD SHX Text
SOCKET OUTLET
AutoCAD SHX Text
OCCUPANCY DETECTOR
AutoCAD SHX Text
DP
AutoCAD SHX Text
PIPE THROUGH FLOOR
AutoCAD SHX Text
INTERRUPTED
AutoCAD SHX Text G
AutoCAD SHX Text
G.F.C.I. RECEPTACLERECEPTACLE
AutoCAD SHX Text
DATA OUTLET
AutoCAD SHX Text D
AutoCAD SHX Text
EMERGENCY LIGHTING FIXTURE
AutoCAD SHX Text
LBE
AutoCAD SHX Text
BLOCK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
GROUNDING CONDUCTOR
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
RECEPTACLES
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
SYSTEM PART
AutoCAD SHX Text
FEEDERS
AutoCAD SHX Text
ACCORDING TO SINGLE
AutoCAD SHX Text
MINIMUM GAUGE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
LINE DIAGRAM
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
1. ALL PIPING SHALL BE 1/2" AND THE CONDUCTOR No.12 AWG EXCEPT WHERE IT ALL PIPING SHALL BE 1/2" AND THE CONDUCTOR No.12 AWG EXCEPT WHERE ITIS SPECIFIED. 2. ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO NTC979 STANDARD OTHERWISE IT SHALL BE EMT. 3. ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A GROUNDING CONDUCTOR AS FOLLOWS:
AutoCAD SHX Text
4. INSULATING AND CONDUCTORS TYPE
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
INSULATING
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
GAUGE
AutoCAD SHX Text
10 AND SMALLER
AutoCAD SHX Text
8 AND LARGER
AutoCAD SHX Text
AWG
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
AutoCAD SHX Text
* ONLY IF NOT COVERED BY THE MINIMUM REQUIRED IN RESOLUTION 90708 OF 2013 NUMERAL 20.2.9 G) THHN-THWN. INSULATION COULD BE USED WARNING SIGN INDICATES THAT GOES UP OR DOWN ACCORDING TO VERTICAL DIAGRAM. WARNING SIGN INDICATES THAT GOES DOWN 1ø3/4" AND GOES THROUGH 1 3/4" EACH FLOOR ACCORDING TO VERTICAL DIAGRAM.WARNING TO INDICATE THAT THIS RECEPTACLE IS SLAVED TO ANOTHER RECEPTACLE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
1 2 3 4 5 6
E
D
C
B
A
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
NOTICE:
THIS DOCUMENT IS THE PROPERTY OF
THE U.S. GOVERNMENT. FURTHER
REPRODUCTION AND/OR DISTRIBUTION IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT
SECTION, BOGOTA, COLOMBIA.
INFORMATION ON THIS DOCUMENT IS NOT
TO BE ALTERED EXCEPT WITH THE
WRITTEN APPROVAL OF THE OFFICE.
MANAGED BY:
I.N.L
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
SHEET No:
A & E DESIGN FIRM:
DIAZ VILLEGAS ARQUITECTOS
www.diazvillegasarquitectos.com
TELEFONO: 6262659 - 7042265
PROJECT:
LOCATION:
CONTRACT NUMBER:
COR VO.Bo.:
OF:
REVIEW:PLAN No:
CONTENIDO:
LEGEND:
REVIEWS:
PHASE:
10% 35% 60% 90% 100%
DRAWING DATE:
SIGNATURE:
PROFFESIONAL CARD:
PROFFESION:
LIFETED BY:
CONTENTS:
No. SUBMITTAL DATE
CONTRACT DATE:
SCALE:
OBSERVATIONS:
SHEET PLAN:
SHEET No:
OF:
REVIEW: PLAN No:
A&E OPERATIONAL CENTER FITOUT,
12 CITIES FOR THE COLOMBIAN
NATIONAL POLICE
SCO150-16-M-0313
OCT 03 / 2016
205-12713 CND
Electrical Engineer
Ing. Julio Cesar Garcia V.
EVW-501
DETALLE VIDEO WALL
EVW-501
1 : 10
087.08-NEIVA-EVW-501.dwg
VIDEO WALL DETAIL
SCALE
ESCALA
VIDEO WALL DETAIL
1:10
DETALLE VIDEO WALL
1:10
B1
AutoCAD SHX Text Nivel Piso
AutoCAD SHX Text
VIDEO WALL 6 PANTALLAS TV DE 55"
AutoCAD SHX Text 13R
AutoCAD SHX Text 13R
AutoCAD SHX Text ø "-2#12+12T34"-2#12+12T
AutoCAD SHX Text 14R
AutoCAD SHX Text 14R
AutoCAD SHX Text ø "-2#12+12T34"-2#12+12T
AutoCAD SHX Text 15R
AutoCAD SHX Text 15R
AutoCAD SHX Text ø "-2#12+12T34"-2#12+12T
AutoCAD SHX Text Cámaras Videoconferencia
AutoCAD SHX Text ø "-2#12+12T34"-2#12+12T
AutoCAD SHX Text
AutoCAD SHX Text 2ø "-c/u 2#12+12T34"-c/u 2#12+12T
AutoCAD SHX Text ø "-2#12+12T 34"-2#12+12T ø "-2(2#12+12T)34"-2(2#12+12T)
AutoCAD SHX Text ø "-2#12+12T34"-2#12+12T
AutoCAD SHX Text 14R
AutoCAD SHX Text T-Regulated
AutoCAD SHX Text T-Regulado
AutoCAD SHX Text
4. AISLAMIENTO Y TIPO DE LOS CONDUCTORES
AutoCAD SHX Text
CONDUCTOR DE TIERRA
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
AISLAMIENTO
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
NOTAS:
AutoCAD SHX Text
CALIBRE
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
TOMACORRIENTES
AutoCAD SHX Text
ALUMBRADO
AutoCAD SHX Text
PARTE DEL SISTEMA
AutoCAD SHX Text
ALIMENTADORES
AutoCAD SHX Text
SEGUN DIAGR.
AutoCAD SHX Text
CALIBRE MINIMO
AutoCAD SHX Text
TIPO DE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
SI
AutoCAD SHX Text
UNIFILAR
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTO TODA LA TUBERÍA SERÁ 1/2" Y EL CONDUCTOR No.12 AWG EXCEPTODONDE SE ESPECIFIQUE. 2. LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA LA TUBERÍA EMBEBIDA EN PLACA O MURO SERÁ TIPO PVC, SEGÚN NORMA NTC 979, DE LO CONTRARIO SERÁ TIPO EMT. 3. TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR TODA LA TUBERÍA DE INSTALACIONES ELÉCTRICAS LLEVARA UN CONDUCTOR DE TIERRA ASÍ:
AutoCAD SHX Text
* SOLO SI NO QUEDA COBIJADO POR LA RESOLUCIÓN MINMINAS 90708 DE 2013 NUMERAL 20.2.9 G) SE PODRÁ UTILIZAR CABLEADO CON AISLAMIENTO THHN-THWN. LLAMADO DE ATENCIÓN QUE INDICA SUBE Y/O BAJA SEGÚN ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE BAJA 1ø3/4" Y PASA 1 3/4" POR CADA UNA DE LAS CUENTAS DE LOS PISOS SUPERIORESSEGÚN INDICA EL ESQUEMA VERTICAL. LLAMADO DE ATENCIÓN PARA EXPRESAR QUE ESTA TOMACORRIENTE ES ESCLAVA DE OTRA TOMACORRIENTE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
4. INSULATING AND CONDUCTORS TYPE
AutoCAD SHX Text
GROUNDING CONDUTOR
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
INSULATING
AutoCAD SHX Text
HFFR-LS *
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
CALINER
AutoCAD SHX Text
10 Y MENORES
AutoCAD SHX Text
8 Y MAYORES
AutoCAD SHX Text
AWG
AutoCAD SHX Text
SOCKETS
AutoCAD SHX Text
LIGHTING
AutoCAD SHX Text
SYSTEM PART
AutoCAD SHX Text
SUPPLIERS
AutoCAD SHX Text
ACCORDING TO SINGLE
AutoCAD SHX Text
MINIMUM CALIBER
AutoCAD SHX Text
CONDUCTOR
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
CABLE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
LINE DIAGRAM
AutoCAD SHX Text
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. ALL PIPING SHALL BE 1/2" AND THE CONDUCT No.12 AWG EXCEPT ALL PIPING SHALL BE 1/2" AND THE CONDUCT No.12 AWG EXCEPTWHERE IT IS SPECIFIED. 2. ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO ALL EMBEDDED PIPING IN SLABS OR WALLS SHALL BE PVC, ACCORDING TO NTC 979 REGULATION, OTHERWISE IT SHALL BE EMT. 3. ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A ALL ELECTRICAL PIPING INSTALLATION WILL BE CONSTRUCTED BY ADDING A GROUNDING CONDUTOR AS FOLLOWS:
AutoCAD SHX Text
* ONLY IF NOT COVERED BY THE MINIMUM RESOLUTION 90708 OF 2013 NUMERAL 20.2.9 G) THHN-THWN. INSULATION COULD BE USED WARNING SIGN INDICATES THAT GOES UP OR DOWN ACCORDING TO VERTICAL DIAGRAM. WARNING SIGN INDICATES THAT GOES DOWN 1ø3/4" AND GOES THROUGH 1 3/4" EACH OF THE SUPERIOR FLOOR COUNTS ACCORDINGTO VERTICAL DIAGRAM. WARNING TO INDICATE THAT THIS OUTLET IS SLAVED TO ANOTHER OUTLET.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HFFR-LS = HALOGEN FREE FLAME RETARDANT - LOW SMOKE
AutoCAD SHX Text
T-GENERAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
T-GENERAL
AutoCAD SHX Text
AutoCAD SHX Text
T-REGULATED
AutoCAD SHX Text
T-REGULADO
AutoCAD SHX Text
T-UTILITY (LIGHTING AND OUTLETS)
AutoCAD SHX Text
T-USO GENERAL (ALUMBRADO Y TOMAS)
AutoCAD SHX Text
T-AIRE (18 CIRCUITOS)
AutoCAD SHX Text
T-AIR (18 CIRCUITS)
AutoCAD SHX Text Llamado de atención para explicar que: El videowall se compone de 6 monitores c/u de 55 pulgadas, cada monitor tendra una tomacorriente doble que sirve al monitor y su respectivo amplificador de señal, de tal forma que en la indicación actual de cada toma se dejaran tres tomas (Altura 1.2m. 1.8m). La alimentación eléctrica del Rack, se compone de 6 circuitos regulados c/u cableado en 2#12+12T Cable aislado.
AutoCAD SHX Text
CIRCUITO REGULADO
AutoCAD SHX Text
EQUIPO
AutoCAD SHX Text
AutoCAD SHX Text Amplificador audio (600 VA) + Grabación CCTV (700 VA)
AutoCAD SHX Text
AutoCAD SHX Text Servidor (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Servidor (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Control de Video (700 VA) + KRM (500 VA)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text = ElectroimánElectroimán
AutoCAD SHX Text Warning sign to explain: Videowall is composed by 6 monitors, 55" each. Each monitor will have a double receptacle which connect the monitor and its signal amplifier, in such way that in the actual receptacle indication, three receptacles will be left. (Height 1.2m. 1.8m). Rack power feeding is composed by 6 regulated circuits, each one 2#12+12T wired with isolated copper.
AutoCAD SHX Text
REGULATED CIRCUIT
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
AutoCAD SHX Text Audio Amplifier (600 VA) + CCTV Recording (700 VA)
AutoCAD SHX Text
AutoCAD SHX Text Server (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Server (1500 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Switch (1300 VA)
AutoCAD SHX Text
AutoCAD SHX Text Control de Video (700 VA) + KRM (500 VA)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text I
= ElectroimánElectroimán
5.00
D
C
B
A
EMBASSY OF THE UNITED STATES
INTERNATIONAL NARCOTICS AND
LAW ENFORCEMENT
BOGOTA, COLOMBIA
NOTICE:
THIS DOCUMENT IS THE PROPERTY OF
THE U.S. GOVERNMENT. FURTHER
REPRODUCTION AND/OR DISTRIBUTION IS
PROHIBITED WITHOUT THE WRITTEN
PERMISSION OF THE INTERNATIONAL
NARCOTICS AND LAW ENFORCEMENT
SECTION, BOGOTA, COLOMBIA.
INFORMATION ON THIS DOCUMENT IS NOT
TO BE ALTERED EXCEPT WITH THE
WRITTEN APPROVAL OF THE OFFICE.
MANAGED BY:
I.N.L
INTERNATIONAL NARCOTICS AND LAW
ENFORCEMENT EMBASSY OF THE
UNITED STATES.
BOGOTA, COLOMBIA
SHEET No:
A & E DESIGN FIRM:
DIAZ VILLEGAS ARQUITECTOS
www.diazvillegasarquitectos.com
TELEFONO: 6262659 - 7042265
PROJECT:
LOCATION:
CONTRACT NUMBER:
COR VO.Bo.:
OF:
REVIEW:PLAN No:
CONTENIDO:
LEGEND:
REVIEWS:
PHASE:
10% 35% 60% 90% 100%
DRAWING DATE:
SIGNATURE:
PROFFESIONAL CARD:
PROFFESION:
LIFETED BY:
CONTENTS:
No. SUBMITTAL DATE
CONTRACT DATE:
SCALE:
OBSERVATIONS:
SHEET PLAN:
SHEET No:
OF:
REVIEW: PLAN No:
A&E OPERATIONAL CENTER FITOUT,
12 CITIES FOR THE COLOMBIAN
NATIONAL POLICE
SCO150-16-M-0313
OCT 03 / 2016
205-12713 CND
Electrical Engineer
Ing. Julio Cesar Garcia V.
EED-502
EED-502
SIN
087.08-NEIVA-EED-502.dwg
TABLE OF CIRCUITS
GROUNDING ROD
DETAIL GROUNDING BUS BAR
CUADRO DE CIRCUITOS
VARILLA PUESTA A TIERRA
DETALLE BARRAJE PUESTA A TIERRA
SCALE
ESCALA
TABLE OF CIRCUITS
SIN
CUADRO DE CIRCUITOS
SIN
A4
SCALE
ESCALA
SINGLE LINE DIAGRAM
SIN
DIAGRAMA UNIFILAR
SIN
C1
SCALE
ESCALA
GROUNDING ROD
SIN
VARILLA PUESTA A TIERRA
SIN
D5
SCALE
ESCALA
DETAIL GROUNDING BUS BAR
SIN
DETALLE BARRAJE PUESTA A TIERRA
SIN
A1
AutoCAD SHX Text
TABLERO
AutoCAD SHX Text
TOMAS O CIRCUITOS ESPECIALES
AutoCAD SHX Text 3ø
AutoCAD SHX Text
G.F.C.I. EN BAÑOS
AutoCAD SHX Text
TOMACORRIENTES
AutoCAD SHX Text 1ø
AutoCAD SHX Text 2ø
AutoCAD SHX Text
CARGA V.A
AutoCAD SHX Text
AUTOMATICOS AMPS
AutoCAD SHX Text
180 VA.
AutoCAD SHX Text 180 V.A
AutoCAD SHX Text
DOBLE DE MURO
AutoCAD SHX Text
REGULADAS
AutoCAD SHX Text
PUNTO DE DERIVACION A LAMPARA
AutoCAD SHX Text
OBSERVACIONES
AutoCAD SHX Text
LAMPARAS
AutoCAD SHX Text
BULLET LED 7W 36º
AutoCAD SHX Text
BULLET LED 7W 8º
AutoCAD SHX Text 20 V.A
AutoCAD SHX Text 10 V.A
AutoCAD SHX Text 10 V.A
AutoCAD SHX Text
180 VA.
AutoCAD SHX Text
DOBLE DE PISO
AutoCAD SHX Text
180 VA.
AutoCAD SHX Text
CIRCUITOS
AutoCAD SHX Text
LBE
AutoCAD SHX Text
TENSOFLEX LAMP 3D
AutoCAD SHX Text 200 V.A
AutoCAD SHX Text
LINEAL LED FLEX STRIP BLANCO
AutoCAD SHX Text 20 V.A
AutoCAD SHX Text
LED FLEX STRIP BLUE
AutoCAD SHX Text 20 V.A
AutoCAD SHX Text
LED TA 2X18W
AutoCAD SHX Text 70 V.A
AutoCAD SHX Text
HERMETIC LED TCI 2X25W
AutoCAD SHX Text 50 V.A
AutoCAD SHX Text
LAMPARA CON BATERIA DE EMERGENCIA
AutoCAD SHX Text 20 V.A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text
T-LIGHTING AND OUTLETS
AutoCAD SHX Text
BOARD
AutoCAD SHX Text
CIRCUITS
AutoCAD SHX Text
LAMPS
AutoCAD SHX Text
OUTLETS
AutoCAD SHX Text
OUTLETS OR SPECIAL CIRCUITS
AutoCAD SHX Text
V.A LOAD
AutoCAD SHX Text
AMPS AUTOMATIC
AutoCAD SHX Text
ANNOTATION
AutoCAD SHX Text
T-ILUMINACION Y TOMAS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 9+6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Alim.ø1¼"-3#8+1#10+1#10T¼"-3#8+1#10+1#10T"-3#8+1#10+1#10T
AutoCAD SHX Text
T-REGULATED
AutoCAD SHX Text
SUMMARY
AutoCAD SHX Text
T-REGULADO
AutoCAD SHX Text
RESUMEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1+1
AutoCAD SHX Text
AutoCAD SHX Text x2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text x2
AutoCAD SHX Text x2
AutoCAD SHX Text 9+14+3
AutoCAD SHX Text 6+4
AutoCAD SHX Text
AutoCAD SHX Text x2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 20000
AutoCAD SHX Text Alim.ø1½"-3#4+1#2+1#4T½"-3#4+1#2+1#4T"-3#4+1#2+1#4T
AutoCAD SHX Text
AutoCAD SHX Text Switch
AutoCAD SHX Text Amplificador CCTV.
AutoCAD SHX Text 18 Cir.=1
AutoCAD SHX Text 24 Cir.=1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1x20=26
AutoCAD SHX Text Toma en Canaleta
AutoCAD SHX Text Luminaria Atenuable
AutoCAD SHX Text Amplificador CCTV.
AutoCAD SHX Text Servidor
AutoCAD SHX Text Servidor
AutoCAD SHX Text Switch
AutoCAD SHX Text Switch
AutoCAD SHX Text Switch
AutoCAD SHX Text Control Video
AutoCAD SHX Text Toma en Canaleta
AutoCAD SHX Text Electroimán
AutoCAD SHX Text Reserva
AutoCAD SHX Text
AutoCAD SHX Text x2
AutoCAD SHX Text
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text 1x20
AutoCAD SHX Text Chute in outlets
AutoCAD SHX Text Dimmable luminaire
AutoCAD SHX Text Server
AutoCAD SHX Text Server
AutoCAD SHX Text Video Control
AutoCAD SHX Text Chute in outlets
AutoCAD SHX Text Electromagnet
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
TABLERO GENERAL DE DISTRIBUCION SALA CRISIS 2AWG
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
EQUIPOS COMUNICACIONES
AutoCAD SHX Text
COMMUNICATION EQUIPMENT
AutoCAD SHX Text 1/0 SPT 5/8" 2.4m
AutoCAD SHX Text
CONEXIONES LIBRES
AutoCAD SHX Text
BARRA DE TIERRAS
AutoCAD SHX Text
EQUIPOS COMUNICACIONES
AutoCAD SHX Text
COMMUNICATION EQUIPMENT
AutoCAD SHX Text
EQUIPOS COMUNICACIONES
AutoCAD SHX Text
COMMUNICATION EQUIPMENT
AutoCAD SHX Text
FREES CONNECTIONS
AutoCAD SHX Text 1/0 SPT 5/8" 2.4m
AutoCAD SHX Text
TABLERO GENERAL DE DISTRIBUCION POLICIA 1/0 AWG
AutoCAD SHX Text
GENERAL PANELBOARD CRISIS ROOM CRISIS 2AWG
AutoCAD SHX Text
GENERAL ELECTRICAL PANELBOARD POLICE 1/0 AWG
AutoCAD SHX Text SE RECOMIENDA LA INSTALACION DE UNA MALLA DE PUESTA A TIERRA DE 5x5m CON 4 VARILLAS DE COBRE, SOLDADURA EXOTERMICA Y TRATAMIENTO AL TERRENO, EQUIPOTENCIALIZAR CON TODAS LAS TIERRAS EXISTENTES Y PROYECTADAS.
AutoCAD SHX Text IT'S RECOMMENDED TO INSTALL A GROUND MESH OF 5.0 X 5.0 WITH 4 COPPER ROD AND TREATMENT FOR ALL GROUND, AND EQUIPOTENTIALIZE WITH ALL EXISTING AND PROJECT GROUNDS.
AutoCAD SHX Text INSPECTION HANDHOLE 30x30x30cm
AutoCAD SHX Text POZO DE INSPECCION 30x30x30cm
AutoCAD SHX Text GROUNDING ROD 2.4m 5/8" Cu.
AutoCAD SHX Text VARILLA DE PUESTA A TIERRA 2.4m 5/8" Cu.
AutoCAD SHX Text MALLA DE PUESTA A TIERRA 5x5m
AutoCAD SHX Text 2/0 Cu.
AutoCAD SHX Text 2/0 Cu.
AutoCAD SHX Text GROUNDING MESH 5x5m
AutoCAD SHX Text DETAIL HANDHOLE COVER 0.3x0.3 cm
AutoCAD SHX Text DETALLE TAPA POZO DE INSPECCION 0.3x0.3 cm
AutoCAD SHX Text
TABLERO GENERAL DE ALIMENTADORES SALA DE CRISIS
AutoCAD SHX Text In=157A. 3Ø,4H,220/127 V. V.V.
AutoCAD SHX Text
RESERVA
AutoCAD SHX Text 3x150
AutoCAD SHX Text 25kA
AutoCAD SHX Text 20kAkA
AutoCAD SHX Text 3x60
AutoCAD SHX Text 20kAkA
AutoCAD SHX Text 20kAkA
AutoCAD SHX Text 3x80
AutoCAD SHX Text 3x3/0+1/0+2T Cu. 3/0+1/0+2T Cu. +1/0+2T Cu. 1/0+2T Cu. ø3"
AutoCAD SHX Text BARRAJE mm. FASE 20x5 NEUTRO 20x3 TIERRA 15x3
AutoCAD SHX Text
DPS B.T.
AutoCAD SHX Text
AutoCAD SHX Text
RESERVA
AutoCAD SHX Text 4 2 4T
AutoCAD SHX Text Ø1½"
AutoCAD SHX Text 6 8 8T
AutoCAD SHX Text Ø1¼"
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text 3x50
AutoCAD SHX Text 8 10 10T
AutoCAD SHX Text Ø1¼"
AutoCAD SHX Text
TABLERO
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text 37.95
AutoCAD SHX Text kVA INSTAL.
AutoCAD SHX Text A.A
AutoCAD SHX Text 14.25
AutoCAD SHX Text 3.7
AutoCAD SHX Text 20.0
AutoCAD SHX Text
ILU Y TOMAS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
BARRA DE TIERRAS
AutoCAD SHX Text
DIAGRAMA UNIFILAR COMANDO REGIONAL DE POLICIA NEIVA S/E 112.5 KVA
AutoCAD SHX Text CABINET INSTALL MEASURING EQUIPMENT B.T. (0.4x0.8x2.0 m.)ACCORDING EXISTING ELECTROHUILA ARMARIO PARA INSTALAR,EQUIPO DE MEDIDA EN B.T. (0.4x0.8x2.0 m.) SEGUN ELECTROHUILA EXISTENTE
AutoCAD SHX Text 3T.C. 300/5A
AutoCAD SHX Text kWh kVARH
AutoCAD SHX Text 3x350
AutoCAD SHX Text 15kA
AutoCAD SHX Text MECANICAL BLOCKING ACCORDING ROLE AE 100 Bloqueador Mecánico Según Norma AE 100
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text GROUND CONNECTION R<5 ohm. 4 Cu-Cu 5/8"x8' PUESTA A TIERRA R<5 ohm. 4 Cu-Cu 5/8"x8'
AutoCAD SHX Text 3 Cortacircuitos 100 A-15 kV. con Hilos Fusibles Tipo Dual
AutoCAD SHX Text
13.200 V. Transformador Trifasico en Poste Refrigerado en Aceite de 112.5 kVA 220/127 V. In=295.3 A. Uz=0.030 Icc=9841.2 A.
AutoCAD SHX Text Y
AutoCAD SHX Text GROUND CONNECTION Cu-Cu 5/8"x8' R 10 ohm. Puesta a Tierra Cu-Cu 5/8"x8' R 10 ohm.
AutoCAD SHX Text
AutoCAD SHX Text 3 Descargadores de Sobre Tensión 12.0 kV.-10 kA. de Oxido Metálico
AutoCAD SHX Text
4 AWG
AutoCAD SHX Text S
AutoCAD SHX Text 3 CIRCUITS BREAKERS 100 A-15kV WITH WINE FUSIBLES DUALTYPE 3 FUSIBLE TIPO NH-2 (400 A.)
AutoCAD SHX Text Baja 2Ø3"
AutoCAD SHX Text GENERAL BOARD COMANDO REGIONAL DE POLICIA NEIVA TABLERO GENERAL COMANDO REGIONAL DE POLICIA NEIVA
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
TABLERO
AutoCAD SHX Text BARRAJE m.m. FASE 40x5 NEUTRO 30x5 TIERRA 20x5
AutoCAD SHX Text 112.5
AutoCAD SHX Text CARGA kVA
AutoCAD SHX Text
AutoCAD SHX Text
T-SALA DE CRISIS
AutoCAD SHX Text 37.95
AutoCAD SHX Text 10kA
AutoCAD SHX Text 3x150
AutoCAD SHX Text Ø3"
AutoCAD SHX Text 3/0 1/0 2T
AutoCAD SHX Text In=420 A. 3Ø,4H,220/127 V.
AutoCAD SHX Text NED LOCAL AREA LEVEL II (13.2kV) EXISTING RED AEREA LOCAL NIVEL II (13.2kV) EXISTENTE
AutoCAD SHX Text X X X
AutoCAD SHX Text 3x..... ACSR ELECTROHUILA S.A ESP.
AutoCAD SHX Text 2(3#4/0#2/0#2T) AluminioAluminio
AutoCAD SHX Text 2(3#350#4/0#2T) Aluminio Aluminio L=100m
AutoCAD SHX Text LA CANTIDAD DE SALIDAS LIBRES EN EL TABLERO GENERAL, DEPENDERA DE LA CANTIDAD DE ALIMENTADORES EXISTENTES EN EL COMANDO DE POLICIA
AutoCAD SHX Text X X X
AutoCAD SHX Text 3x..... ACSR ELECTROHUILA S.A ESP.
AutoCAD SHX Text THE INSTALLATION OF THR NEW 112.5kVA TRANSFORMERS IS PLANNED ON THE EXISTING STUCTURE SE HA PROYECTADO EL MONTAJE DEL NUEVO TRANSFORMADOR DE 112.5kVA SOBRE LA ESTRUCTURA EXISTENTE.
AutoCAD SHX Text THE LOCATION OF THE GENERAL DISTRIBUTION BOARD SHOULD BE COORDINATED. FROM HERE IT HAS TO FEED THE NEW OPERATING ROOM
AutoCAD SHX Text AL GRUPO DE MEDIDA EXISTENTE SE LE DEBERAN CAMBIAR LOS TRANSFORMADORES DE CORRIENTE Y LA PROTECCION PRINCIPAL SEGUN EL DIAGRAMA UNIFILAR
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
Auto…
This is the start of the file's text. The full file is on GovTribe.