Salient Characteristics for XFMR Purchase.pdf

PDF 205 KB Posted

Attached to
7 CES Transformers
Solicitation number
FA466126Q0111
Issued by

About this file

This document specifies the salient characteristics of three transformer products required under a federal contract solicitation.

CLIN 0001 requires a 300 KVA three-phase 120/208VAC Delta Y configuration ABB transformer with 12470 Delta high voltage at 95 kV BIL, equipped with two above and two below taps at 2.5%, and six 200A Wells & Inserts dead front loop feed bushings. The low voltage rating is 208 Y/120 at 30 kV BIL with four 4-hole spade bushings. Specifications include mineral oil fluid, 65°C temperature rise, ONAN cooling class, aluminum conductors, no fusing, 4-position LBOR switch, mild steel tank, and standard cabinet depth. The unit shall include a liquid level gauge, pressure vacuum gauge, dial-type thermometer, grounding provisions, Schrader valve, drain and sample valve, pressure relief valve, padmount green paint finish, and UL listing.

CLIN 0002 requires a 150 KVA three-phase 120/208VAC Delta Y configuration ABB transformer with identical high voltage specifications (12470 Delta, 95 kV BIL) and taps as CLIN 0001, along with the same low voltage configuration and accessories. CLIN 0003 requires a 100 KVA single-phase 120/208VAC pad mount ABB transformer operating at 65°C and 60Hz with standard impedance, 12470Y 7200 primary voltage at 95 kV BIL with loop feed, 240/120 secondary voltage at 30 kV BIL, no primary taps, 200A dead front wells with 15 kV insert primary bushings, 4-hole spade secondary bushings, bayonet fusing with fuse holder assembly, and FR3 insulating fluid.

View the file

Other files

File Type Posted
Vendor Questions - Answered 2.docx DOCX document
RFQ FA466126Q0111 Ammendment 2.pdf PDF
Vendor Questions - Answered.docx DOCX document
RFQ FA466126Q0111 Ammendment 1.pdf PDF
RFQ FA466126Q0111.pdf PDF
Atatchement 2 - Provisions and Clauses.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics of the Requested Transformers CLIN 0001: 300 KVA 3PH 120/208VAC Delta Y configuration ABB Transformer

High Voltage:

12470 Delta, 95 kV BIL

Taps: 2 Above, 2 Below @ 2.5%

HV Bushings: (6) 200A Wells & Inserts (dead front, loop feed)

Low Voltage:

208 Y/ 120, 30 kV BIL

LV Bushings: (4) 4-Hole Spades

Specifications:

Fluid: Mineral Oil

Temperature Rise:

65C Cooling Class:

ONAN Conductor: Al /

Al Fusing: None

Switch: 4 Pos. LBOR

Tank Material: Mild

Steel Arresters: None

Cabinet Depth: Standard

Features and Accessories:

Liquid Level Gauge

Pressure Vacuum Gauge

Dial-Type Thermometer

Grounding Provisions

Schrader Valve

Drain & Sample Valve

Pressure Relief Valve

Padmount Green Paint

UL Listed

CLIN 0002: 150 KVA 3PH 120/208VAC Delta Y configuration ABB Transformer

CLIN 0003 : 100 KVA 1PH 120/208VAC ABB Transformer

File details come from the government source that posted it. Updated .