S02 Vol 1-0.pdf
PDF 8 MB Posted
- Solicitation number
- 36C24225R0007
About this file
This file contains the first portion of the Bid Document drawings for VA Project 632-16-101 "Upgrade Emergency Generators Phase I" at the Northport VA Medical Center in New York. The drawings include general project information, life safety plans, infection control plans, site plans, and detailed architectural, structural, mechanical, electrical and plumbing drawings for a new 2,000 GSF building addition.
The scope involves replacing the hospital's generator emergency system by constructing a new building addition to house two new emergency generators with space for a future third generator, installing underground fuel storage tanks, and removing existing Building 200 generator/fuel tanks. The work includes demolition of existing equipment, installation of new concrete pads for chillers and switchgear, and providing a temporary emergency generator during construction to maintain power. The project requires careful coordination of utilities and protection of critical infrastructure that must remain operational, including the loading dock access road, 15KVA primary duct bank, and underground utilities. The drawings emphasize infection control requirements, life safety measures, and maintaining hospital operations during construction through detailed phasing and temporary measures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24224R0033 PROPOSAL ITEMS.docx | DOCX document | |
| S06_Custom Soil Resource Report.pdf | ||
| 36C24225R0007 0003.docx | DOCX document | |
| Site Visit Sign Sheet.doc | DOC document | |
| S06_Drawing_Amend.pdf | ||
| P07_Wage Determination.txt | TXT text file | |
| Construction Cost Breakdown Sheet.pdf | ||
| 36C24225R0007 0002.docx | DOCX document | |
| 36C24225R0007 0001.docx | DOCX document | |
| Wage Determination.pdf | ||
| S02 Vol 1-1.pdf | ||
| S02 Vol 1-2.pdf | ||
| FAR 52.225-2 Buy American Certification.pdf | ||
| 013200 Construction Documentation.docx | DOCX document | |
| S02 Vol 3-1.pdf | ||
| 852.219-77 VA Notice of Limitations on Subcontracting.docx | DOCX document | |
| S02 Vol 1-3.pdf | ||
| 36C24225R0007.docx | DOCX document | |
| S02 Vol 3-0.pdf | ||
| Past Performace Questionaire_PPQ.pdf | ||
| S02 Vol 1.pdf | ||
| S02 Vol 2.pdf | ||
| S02 Vol 3-2.pdf | ||
| S02 Vol 2-0.pdf | ||
| S02 Vol 2-1.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UPGRADE EMERGENCY
632-16-101
NOVEMBER 9, 2023
GENERATORS
H A R R E L L
DESIGN GROUP, PC
FULLY SPRINKLERED
BID DOCUMENTS
COVER SHEET
GI001
GENERAL
GI001 COVER SHEET
GI101 BUILDING 200 LIFE SAFETY PLAN
GI102 BUILDING 200 INTERIM LIFE SAFETY PLAN
GC101 ICRA PLAN
SURVEY
V100 EXISTING SITE PLAN
V101 TOPOGRAPHIC SURVEY
CIVIL
C-0.0 DEMOLITION PLAN
C-1.0 LAYOUT AND MATERIALS PLAN
C-2.0 GRADING, DRAINAGE, AND UTILITIES PLAN
C-3.0 DETAILS
C-3.1 DETAILS
C-3.2 DETAILS
STRUCTURAL
S001 STRUCTURAL GENERAL NOTES
S002 STRUCTURAL GENERAL NOTES
S003 FOUNDATION TYPICAL DETAILS
S004 FRAMING TYPICAL DETAILS
S101 FOUNDATION PLAN
S102 STRUCTURAL ROOF FRAMING PLAN
S301 STRUCTURAL SECTIONS AND DETAILS
S302 STRUCTURAL SECTIONS AND DETAILS
S303 STRUCTURAL SECTIONS AND DETAILS
ARCHITECTURAL
AI001 ARCHITECTURAL GENERAL NOTES & ABBREVIATIONS
AD001 ARCHITECTURAL DEMOLITION SITE PLAN
AD101 ARCHITECTURAL DEMOLITION PLAN
AS101 ARCHITECTURAL SITE PLAN
AE101 FLOOR PLAN
AE102 ROOF PLAN
AE201 BUILDING ELEVATIONS
AE301 BUILDING SECTION
AE302 BUILDING SECTION
AE401 ARCHITECTURAL DETAILS
AE402 ARCHITECTURAL DETAILS
AE601 DOOR SCHEDULE & DETAILS
AF101 ARCHITECTURAL FINISHES PLAN
AF601 FINISH SCHEDULE & SIGNAGE SCHEDULE
FIRE ALARM
FA001 LEGEND, MATRIX, RISER, AND NOTES
FA101 FLOOR PLAN - FIRE ALARM
FIRE PROTECTION
FP001 FIRE PROTECTION GENERAL NOTES, LEGENDS, &
SYMBOLS
FP101 FIRE PROTECTION FLOOR PLAN
PLUMBING
P001 PLUMBING NOTES, SYMBOLS, LEGENDS, & SCHEDULES
PD101 PLUMBING DEMOLITION FLOOR PLAN
P101 PLUMBING FLOOR PLAN
P102 PLUMBING ROOF PLAN
P501 PLUMBING DETAILS & SCHEMATICS
MECHANICAL
MH001 MECHANICAL LEGEND AND GENERAL NOTES
MD101 MECHANICAL DEMOLITION FLOOR PLAN
MH101 MECHANICAL FLOOR PLAN
MH102 MECHANICAL ROOF PLAN
MP100 MECHANICAL PIPING SUB-BASEMENT FLOOR PLAN
MP101 MECHANICAL PIPING FLOOR PLAN
MP102 MECHANICAL PIPING ROOF PLAN
MH501 MECHANICAL DETAILS
MH502 MECHANICAL DETAILS
MH601 MECHANICAL SCHEDULES
MH701 MECHANICAL CONTROLS
ELECTRICAL
EG001 LEGENDS, GENERAL NOTES, AND SCHEDULES
ED101 ELECTRICAL DEMOLITION PLAN
EL101 FLOOR PLAN - LIGHTING
EP101 FLOOR PLAN - POWER
EE102 ROOF PLAN - ELECTRICAL
EP103 LOWER LEVEL PLAN - POWER
EP104 PENTHOUSE PLAN - POWER
EY101 FLOOR PLAN - SYSTEMS
EY103 LOWER FLOOR PLAN - SYSTEMS
EE401 EQUIPMENT ELEVATIONS
EE402 ENLARGED GENERATOR ROOM
EE403 ENLARGED ELECTRICAL ROOM AND GENERATOR
EQUIPMENT ROOM PLAN DEMOLITION
EE404 ENLARGED ELECTRICAL ROOM AND GENERATOR
EQUIPMENT ROOM PLAN POWER
EE405 ENLARGED 200N ELECTRICAL PLANS
EE501 ELECTRICAL DETAILS
EE502 ELECTRICAL DETAILS
EE601 EXISTING ELECTRICAL SINGLE LINE DIAGRAM -
DEMOLITION
EE602 NEW ELECTRICAL SINGLE LINE DIAGRAM
EE701 ELECTRICAL EQUIPMENT SCHEDULE
EE702 PANEL SCHEDULES
EE703 PANEL SCHEDULES
EE704 PANEL SCHEDULES
E
N
NW
SW
NE
SE
S
W
THE SCOPE OF WORK IS TO REPLACE THE HOSPITAL'S GENERATOR EMERGENCY SYSTEM.
THIS PROJECT ENTAILS CIVIL, STRUCTURAL, ARCHITECTURAL AND MECHANICAL/ELECTRICAL/PLUMBING WORK TO PROVIDE FOR A NEW 2000 GSF BUILDING ADDITION THAT WILL HOUSE 2 NEW EMERGENCY GENERATORS AND SPACE FOR A FUTURE 3RD GENERATOR, WITH UNDERGROUND FUEL STORAGE TANKS.
DEMOLITION INCLUDES REMOVAL OF EXISTING BUILDING 200 GENERATOR AND FUEL TANKS AND AUTOMATIC TRANSFER SWITCHES. THE EXISTING GENERATOR ROOM WILL RECEIVE NEW CONCRETE PADS FOR THE INSTALLATION OF A NEW CHILLER AND SWITCHGEAR, AND THE EXISTING SWITCHGEAR ROOM WILL RECEIVE
A NEW CONCRETE PAD FOR NEW SWITCHBOARD.
THE SCOPE OF WORK FOR THE BOILER BUILDING 203 REPLACEMENT GENERATOR IS AS FOLLOWS:
BUILDING 203 WORK INCLUDES REMOVAL OF THE EXISTING EMERGENCY GENERATOR AND ITS AUTOMATIC TRANSFER SWITCH BY REMOVING THE EXISTING BUILDING LOUVER AS IDENTIFIED IN THE DOCUMENTS. THE EXISTING GENERATOR ROOM RECEIVES A NEW 250 KW GENERATOR, CONCRETE PAD AND A NEW AUTOMATIC TRANSFER SWITCH SHALL BE LOCATED IN THE EXISTING SWITCHGEAR ROOM. DURING THIS PERIOD A TEMPORARY EMERGENCY GENERATOR WILL BE PROVIDED TO MAINTAIN EMERGENCY POWER SERVICE FOR THE DURATION OF THE CONSTRUCTION.
LOCATION MAP
CAMPUS MAP LIST OF DRAWINGS
PROJECT DESCRIPTION AND GENERAL REQUIREMENTS
E
N
NW
SW
NE
SE
S
W
THE MECHANICAL CONTRACTOR SHALL TAKE THE LEAD IN PREPARATION OF COORDINATION DRAWINGS. SUCH DRAWINGS SHALL BE ARRANGED AND DESIGNED THROUGH AND FROM COORDINATION WITH ALL OTHER MAJOR AND MINOR SUBCONTRACTORS AND THE GENERAL CONTRACTOR. PROVIDE PLAN VIEWS, SECTIONS AND ELEVATIONS AS REQUIRED TO FULLY COORDINATE ALL NEW WORK WITH ITSELF AND EXISTING CONDITIONS. DRAW TO SCALE (AT NOT LESS THAN 3/8" = 1'-0"). DRAWINGS SHALL SHOW, BUT NOT BE LIMITED TO: ALL DUCTWORK; ALL AIR DISTRIBUTION; MECHANICAL EQUIPMENT; MECHANICAL PIPING; FIRE PROTECTION PIPING; ALL PLUMBING PIPING; CABLE TRAYS (WITH ELEVATIONS NOTED); LIGHTING FIXTURES (WHEN CEILING MOUNTED); CEILING GRID AND CEILING HEIGHT; MAJOR BEAMS AND JOISTS (WITH ELEVATIONS MARKED); FIRE ALARM DEVICES AND SPEAKERS (WHERE CEILING MOUNTED); ELECTRICAL CONDUITS LARGER THAN 2-INCH DIAMETER; ELECTRICAL BUSWAY AND REQUIRED CLEARANCES; EQUIPMENT PROVIDED BY OTHERS THAT PROTRUDE INTO CEILING CAVITIES OR IMPEDE THE LOCATION OR ACCESS TO ABOVE CEILING PIPING, HANGER SUPPORTS FOR PATIENT LIFTS, DUCTWORK OF OTHER EQUIPMENT.
SECTIONS SHALL BE CUT THROUGH AREAS SHOWING MATERIALS AND SYSTEMS OF ALL CONTRACTS. IF THERE ARE ANY OUTSTANDING ISSUES THAT CANNOT BE RESOLVED, CONSULT WITH THE ARCHITECT AND/OR ENGINEER (THROUGH THE VA COR) FOR GUIDANCE AND MAKE CORRECTIONS IN ACCORDANCE WITH DIRECTIONS GIVEN. IT IS IMPORTANT TO NOTE THAT FABRICATION CANNOT BEGIN UNTIL COORDINATION DRAWINGS HAVE BEEN APPROVED. ANY MATERIAL, EQUIPMENT, SYSTEMS, ETC., PROCUREMENT OR INSTALLATION COMMENCED PRIOR TO APPROVAL IS TAKEN AT THE CONTRACTORS OWN RISK AND MAY HAVE
TO BE MODIFIED, MOVED AND/OR RECONFIGURED AT THE CONTRACTORS COST.
COORDINATION DRAWINGS
NORTHPORT VA MEDICAL CENTER
UPGRADE EMERGENCY GENERATORS PH. 1
79 MIDDLEVILLE ROAD - NORTHPORT, NY 11768
VETERANS HEALTH ADMINISTRATION
| PROJECT NUMBER: 632-16-101
ITEMS REMAINING IN SERVICE DURING CONSTRUCTION REQUIRING CONTRACTOR PROTECTION:
1. LOADING DOCK ACCESS: EXISTING LOADING DOCK ACCESS ROAD MUST REMAIN IN SERVICE
DURING THE ENTIRE CONSTRUCTION PERIOD FOR THIS PROJECT. COVER EXCAVATIONS DAILY W/
1-1/4” THICK ASTM A36 STEEL ROAD PLATES CAPABLE OF SUPPORTING H-20 TRUCK LOADS.
PROVIDE TEMPORARY PROVISIONS INCLUDING STEEL ROAD PLATES, PHASED TRENCH WORK,
FLAGMEN, AND CAUTION SIGNAGE.
2. 15KVA PRIMARY DUCT BANK: EXISTING 15KVA PRIMARY DUCT BANK MUST REMAIN IN SERVICE, PROTECTED, AND UNDISTURBED DURING THE PROJECT'S ENTIRE CONSTRUCTION PERIOD. INSTALL
SHEETING AND SHORING ALONG DUCT BANK EDGES ADJACENT TO CONSTRUCTION.
3. UNDERGROUND UTILITIES: UNDERGROUND UTILITIES IN PLAN SOUTH AREA OF THE PROJECT
AREA SHALL REMAIN IN SERVICE FOR THE PROJECT DURATION, WITHOUT DISTURBANCE. ALL
REQUESTED MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL SHUTDOWNS SHALL BE
REQUESTED FROM, COORDINATED WTH, AND APPROVED BY THE VA-COR. SHUTDOWN REQUESTS
MUST PROVIDE WRITTEN PLAN DESCRIBING AFFECTED UTILITIES, DURATION, AND SAFETY
PRECAUTIONS (ACTIVITY HAZARD ANALYSES--SEE SPEC SECTION 013526). SUBMIT WRITTEN
SHUTDOWN REQUESTS TO VA-COR NOT LESS THAN 14 CALENDAR DAYS PRIOR TO THE REQUESTED
SHUTDOWN.
PROJECT DESCRIPTION
A. ITEM 1; GENERAL CONSTRUCTION: THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TOOLS, LABOR, MATERIAL, EQUIPMENT, PERMITS, LICENSES, AND SUPERVISION FOR "UPGRADE EMERGENCY GENERATORS PHASE 1" PROJECT NUMBER 632-16-101 IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. WORK INCLUDES BUT IS NOT LIMITED TO, SITE WORK, SITE DEMOLITION, REMOVAL OF UNDERGROUND FUEL STORAGE TANK, NEW ADDITION FOR EMERGENCY GENERATORS, INTERIOR RENOVATION, CONSTRUCTION, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL, FIRE ALARM, AND FIRE
PROTECTION.
B. ITEM 2; DEDUCT ALTERNATE 1: PERFORM ALL WORK AS STATED IN BID ITEM 1, EXCEPT REMOVE ALL WORK IN BUILDING 200N (ROOM D0-5 GENERATOR ROOM)
FROM THE SCOPE OF WORK.
SCHEDULE OF BID ITEMS
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text Affairs
AutoCAD SHX Text Date
AutoCAD SHX Text Project Number
AutoCAD SHX Text DRAWING No.
AutoCAD SHX Text Building Number
AutoCAD SHX Text Reviewed
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Const. Contract No.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Veterans
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Department of Veterans Affairs
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text By
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BC
AutoCAD SHX Text
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
REVISION DESCRIPTION
AutoCAD SHX Text
REVISION NO.
AutoCAD SHX Text
SEAL
AutoCAD SHX Text Recommended Approvals:
AutoCAD SHX Text
1. MEDICAL DIRECTOR
AutoCAD SHX Text
6. OPERATIONS SERVICE LINE MANAGER
AutoCAD SHX Text
7. INFECTION CONTROL MANAGER
AutoCAD SHX Text
2. ASSOCIATE DIRECTOR
AutoCAD SHX Text
8. SAFETY MANAGER
AutoCAD SHX Text
3. CHIEF OF STAFF
AutoCAD SHX Text
4. ASSOC. DIRECTOR
AutoCAD SHX Text
9. GENERAL ENGINEER
AutoCAD SHX Text
5. SERVICE LINE MGRS.
AutoCAD SHX Text
10. COR
AutoCAD SHX Text Architect/Engineer Address
AutoCAD SHX Text
WWW.HARRELLDG.COM
AutoCAD SHX Text F 704.321.0833
AutoCAD SHX Text P 704.814.1320
AutoCAD SHX Text
CHARLOTTE, NC 28227
AutoCAD SHX Text
8016 TOWER POINT DRIVE
AutoCAD SHX Text
COPYRIGHT HARRELL DESIGN GROUP, PC
AutoCAD SHX Text c
AutoCAD SHX Text
AutoCAD SHX Text
HDG PROJECT # 17011
AutoCAD SHX Text
NORTHPORT VA MEDICAL CENTER
AutoCAD SHX Text
NORTHPORT, NY 11768
AutoCAD SHX Text
79 MIDDLEVILLE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
GG
AutoCAD SHX Text
LK
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
PROJECT LOCATION AT HOSPITAL
jcarr JC NC Electronic Seal.jpg
ASPHALT
ELECTRICAL MH
GRASS
WALK
EXISTING
UPGRADE EMERGENCY
632-16-101
NOVEMBER 9, 2023
GENERATORS
H A R R E L L
DESIGN GROUP, PC
FULLY SPRINKLERED
BID DOCUMENTS
BUILDING 200
LIFE SAFETY PLAN
GI101
START OF EGRESS ROUTE
DIRECTION OF TRAVEL
END OF EGRESS ROUTE (EXIT)
PROVIDED EGRESS WIDTH
MINIMUM REQUIRED EGRESS WIDTH
EGRESS OCCUPANT LOAD
EXIT SIGN
OCCUPANT LOAD PER ROOM
ROOM AREA
## NET
### SQFT
## PEOPLE
NAME ROOM NAME
AREA PER OCCUPANT (NET OR GROSS)
X" REQ'D.
X" PROV'D.
# PEOPLE
FEC SEPARATION TRAVEL
COMMON PATH OF TRAVEL
REQUIRED EXIT
APPLICABLE CODES IN ORDER OF PRECEDENCE:
OCCUPANCY CLASSIFICATION:
MAIN USE:
SECONDARY USES: N/A
HIGH-RISE / NOT HIGH-RISE: NOT HIGH-RISE ( 3.3.36.7 )
NO. OF STORIES ( PROPOSED / PERMITTED ): 3 STORIES / 1 STORY
CONSTRUCTION TYPE LIMITATIONS: NFPA 101 TABLE 20.1.6.1
HEIGHT (FT) TO ROOF ( PROPOSED / PERMITTED ): 3 STORIES / 1 STORY
MINIMUM CONSTRUCTION CLASSIFICATION: TYPE II (222)
RELEVANT FIRE RESISTANCE RATINGS PER NFPA TABLE A.8.2.1.2:
FIRE SEPARATION DISTANCE NA
CONSTRUCTION ELEMENT TYPE II (222) UL DESIGN
REQUIRED RATING (IF APPLICABLE)
ROOF CEILING / ASSEMBLY 1 UL P701
BEAMS, GIRDERS, TRUSSES, AND ARCHES 1 UL P701)
[SUPPORTING ROOFS ONLY]
COLUMNS [SUPPORTING ROOF ONLY] 1 UL X845
MAX. PERMITTED AREA UL SF
EXISTING SQFT ON PROPOSED FLOOR
NEW ADDITION 1,747 SQFT
NEW FIRST FLOOR TOTAL (EXISTING + NEW) 144,380 SQFT
AUTOMATIC QUICK RESPONSE HEAD SPRINKLERS THROUGHOUT: YES
PER VA FIRE PROTECTION DESIGN MANUAL (2015, P.23 (K)), SEE FIRE PROTECTION
DRAWINGS FOR FURTHER CLARIFICATION
NFPA 101 20.3.7.3 - MAX SMOKE COMPARTMENT PERMITTED = 40,000 SQFT
NFPA 101 20.3.7.3 TABLE 40.2.6 - MAX TRAVEL DISTANCE WITHIN SMOKE BARRIER = 400 FT
STANDPIPE SYSTEM: NO
SEPARATION OF USES: YES, 2 HR PER NFPA 101, TABLE 6.1.14.4.1(6)
AREA INCREASE DUE TO OPEN SPACE: N/A
AREA INCREASE FOR SPRINKLER SYSTEM: N/A
FLOOR AREA (SF) LARGEST FLOOR ( PROPOSED / PERMITTED BY CONSTRUCTION TYPE):
UL
TOTAL PERMITTED FLOOR AREA WITH AREA INCREASES: N/A
ELECTRICAL SUPERVISION OF AUTOMATIC SPRINKLER SYSTEMS:
YES ( 9.7.2 )
ELECTRICAL SUPERVISION OF BUILDING ALARM AND FIRE DETECTION DEVICES:
YES ( 9.6.2 )
FIRE DEPARTMENT NOTIFICATION VIA APPROVED MONITORING OF FIRE SUPPRESSION,
DETECTION AND ALARM DEVICES: YES ( 9.6.4 )
FIRE ALARM SYSTEM SOUNDS AN AUDIBLE AND VISIBLE ALARM IN A CONSTANTLY
ATTENDED RECEIVING STATION WITHIN THE BUILDING: YES (9.6.7 )
BUILDING FIRE COMMAND CENTER: NO
SEISMIC AND WIND LOADING:
PER VA H-18-8 SEISMIC DESIGN MANUAL, P. 15 - SEISMIC BRACING IS NOT REQUIRED,
EXCEPT 4.1 (C) NFPA 13 9.3.5
CODE SUMMARY
INDUSTRIAL OCCUPANCIES
NFPA 101 CHAPTER 40
SUBCLASSIFICATION IS "SPECIAL-PURPOSE
INDUSTRIAL CLASSIFICATION"
ORDINARY HAZARD
ROOF-CEILING ASSEMBLY 1 HOUR
EXTERIOR NON-BEARING WALLS 0 HOUR
142,633 SQFT
HEADROOM AND CORRIDOR / AISLE WIDTH:
MINIMUM HORIZONTAL DIMENSION: 22 IN. CLEAR
MINIMUM HEADROOM: 6'-8"
MINIMUM DOOR WITH: 22 IN. CLEAR
CODE EDITIONS
NFPA 10 PORTABLE FIRE EXTINGUISHERS, 2018 EDITION
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2019 EDITION
NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS, 2019 EDITION NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2019 EDITION
NFPA 54 NATIONAL FUEL GAS CODE, 2018 EDITION
NFPA 70 NATIONAL ELECTRICAL CODE, 2020 EDITION
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2019 EDITION
NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2019 EDITION
NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2018 EDITION NFPA 90B STANDARD FOR THE INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS, 2018 EDITION NFPA 96 STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS, 2017 EDITION
NFPA 99 HEALTH CARE FACILITIES CODE, 2018 EDITION
NFPA 101 LIFE SAFETY CODE, 2018 EDITION
NFPA 105 STANDARD FOR SMOKE DOOR ASSEMBLIES AND OTHER OPENING PROTECTIVES, 2019 EDITION
NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, 2019 EDITION
NFPA 241 STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2019 EDITION ASHRAE 90.1 ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS, 2016 EDITION
NFPA 220 STANDARD ON TYPES PF BUILDING CONSTRUCTION
NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE
FIRE EXTINGUISHER MOUNTED ON WALL, W/ AMEREX
EXTINGUISHER BRACKET (TOP MAX. @ 3'6" AFF)
ITEMS REMAINING IN SERVICE DURING CONSTRUCTION REQUIRING CONTRACTOR PROTECTION:
1. LOADING DOCK ACCESS: EXISTING LOADING DOCK ACCESS ROAD MUST REMAIN IN SERVICE
DURING THE ENTIRE CONSTRUCTION PERIOD FOR THIS PROJECT. COVER EXCAVATIONS DAILY W/
1-1/4” THICK ASTM A36 STEEL ROAD PLATES CAPABLE OF SUPPORTING H-20 TRUCK LOADS.
PROVIDE TEMPORARY PROVISIONS INCLUDING STEEL ROAD PLATES, PHASED TRENCH WORK,
FLAGMEN, AND CAUTION SIGNAGE.
2. 15KVA PRIMARY DUCT BANK: EXISTING 15KVA PRIMARY DUCT BANK MUST REMAIN IN SERVICE, PROTECTED, AND UNDISTURBED DURING THE PROJECT'S ENTIRE CONSTRUCTION PERIOD. INSTALL
SHEETING AND SHORING ALONG DUCT BANK EDGES ADJACENT TO CONSTRUCTION.
3. UNDERGROUND UTILITIES: UNDERGROUND UTILITIES IN PLAN SOUTH AREA OF THE PROJECT
AREA SHALL REMAIN IN SERVICE FOR THE PROJECT DURATION, WITHOUT DISTURBANCE. ALL
REQUESTED MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL SHUTDOWNS SHALL BE
REQUESTED FROM, COORDINATED WTH, AND APPROVED BY THE VA-COR. SHUTDOWN REQUESTS
MUST PROVIDE WRITTEN PLAN DESCRIBING AFFECTED UTILITIES, DURATION, AND SAFETY
PRECAUTIONS (ACTIVITY HAZARD ANALYSES--SEE SPEC SECTION 013526). SUBMIT WRITTEN
SHUTDOWN REQUESTS TO VA-COR NOT LESS THAN 14 CALENDAR DAYS PRIOR TO THE REQUESTED
SHUTDOWN.
NEW ADDITION
CONSTRUCTION TYPE
II (2,2,2) SPECIAL
PURPOSE INDUSTRIAL
2 HR FIRE BARRIER
MAIN HOSPITAL
EXISTING HEALTHCARE
CONSTRUCTION TYPE II
(2,2,2)
EXISTING BUILDING TO
REMAIN
FE FE
FE
RE
RE
RE
RE32" REQ'D.
68" PROV'D.
24 PEOPLE
32" REQ'D.
92" PROV'D.
24 PEOPLE
32" REQ'D.
92" PROV'D.
10 PEOPLE
TD LEG 2 - 102.4'
CPOT = 19'
TD LEG 1 - 88.5'
CPOT = 56.5'
RE
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DAY TANK (FUTURE)
AutoCAD SHX Text
SHAFT.7
AutoCAD SHX Text
SHFT. 16
AutoCAD SHX Text
SHFT. 5
AutoCAD SHX Text
SHAFT. 6
AutoCAD SHX Text
SWITCHGEAR
AutoCAD SHX Text A0-28
AutoCAD SHX Text
STAFF.TOIL
AutoCAD SHX Text
AO-29
AutoCAD SHX Text
CLEANLINEN
AutoCAD SHX Text A0-20C
AutoCAD SHX Text
X-RAY FILE
AutoCAD SHX Text A0-20
AutoCAD SHX Text
TELECOMMUNICATION
AutoCAD SHX Text B0-24F
AutoCAD SHX Text
ELEC. RM.
AutoCAD SHX Text B0-29A
AutoCAD SHX Text
CL.
AutoCAD SHX Text B0-22A
AutoCAD SHX Text
AC.SHOP
AutoCAD SHX Text B0-26
AutoCAD SHX Text
ELEV. LOBB
AutoCAD SHX Text A0-5
AutoCAD SHX Text A0-15A
AutoCAD SHX Text
AO-26
AutoCAD SHX Text
STAFF.TOIL
AutoCAD SHX Text A0-11C
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text A0-20A
AutoCAD SHX Text A0-C3B
AutoCAD SHX Text
ST. 5
AutoCAD SHX Text 148.75
AutoCAD SHX Text F-5
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text A0-C2
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text B0-C2
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A0-11D
AutoCAD SHX Text
UTILITY
AutoCAD SHX Text A0-17
AutoCAD SHX Text
CATEEN PRE
AutoCAD SHX Text A0-2
AutoCAD SHX Text
WAITING ROOM
AutoCAD SHX Text A0-20A
AutoCAD SHX Text
X-RAY FILE
AutoCAD SHX Text A0-10D
AutoCAD SHX Text
TOILET
AutoCAD SHX Text D0-6
AutoCAD SHX Text
PUMP RM.
AutoCAD SHX Text A0-4
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text D0-C2B
AutoCAD SHX Text
ST. 7
AutoCAD SHX Text D0-C2C
AutoCAD SHX Text
FEC
AutoCAD SHX Text A0-16A
AutoCAD SHX Text
AGENT CASH
AutoCAD SHX Text A0-6
AutoCAD SHX Text
DARK ROOM
AutoCAD SHX Text A0-22
AutoCAD SHX Text
SPD
AutoCAD SHX Text A0-10B
AutoCAD SHX Text A0-14
AutoCAD SHX Text
BENEFICARY
AutoCAD SHX Text B0-25
AutoCAD SHX Text
HOUSEKEEPI
AutoCAD SHX Text A0-10C
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text A0-19
AutoCAD SHX Text
CATEEN PRE
AutoCAD SHX Text A0-1
AutoCAD SHX Text
RECEPTIONIST
AutoCAD SHX Text B0-24C
AutoCAD SHX Text
FEC
AutoCAD SHX Text A0-10
AutoCAD SHX Text
CREDIT
AutoCAD SHX Text A0-13
AutoCAD SHX Text B0-C24B
AutoCAD SHX Text
C.CLOSET
AutoCAD SHX Text B0-C24D
AutoCAD SHX Text
ST.1
AutoCAD SHX Text 131.34
AutoCAD SHX Text A0-7
AutoCAD SHX Text A0-9A
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text B0-C24E
AutoCAD SHX Text
ELEC. CL.
AutoCAD SHX Text B0-15
AutoCAD SHX Text
SPIECT.CAM
AutoCAD SHX Text A0-15
AutoCAD SHX Text
AGENT CASH
AutoCAD SHX Text
AO-22E
AutoCAD SHX Text
TOILET
AutoCAD SHX Text A0-25
AutoCAD SHX Text
SPECIMEN ROOM
AutoCAD SHX Text A0-21
AutoCAD SHX Text
KITCHEN ME
AutoCAD SHX Text B0-23A
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text B0-27M
AutoCAD SHX Text
ELEC. CL.
AutoCAD SHX Text B0-22
AutoCAD SHX Text
SWITCHGEAR
AutoCAD SHX Text B0-19
AutoCAD SHX Text
TOILET
AutoCAD SHX Text A0-C2
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AO-11B
AutoCAD SHX Text A0-C6
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A0-30
AutoCAD SHX Text B0-C24A
AutoCAD SHX Text
C.CLOSET
AutoCAD SHX Text F-4
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text B0-30A
AutoCAD SHX Text B0-C3
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
ELEVATOR 3
AutoCAD SHX Text
HOUSEKEEPI
AutoCAD SHX Text
BO-27B
AutoCAD SHX Text B0-22B
AutoCAD SHX Text B0-24
AutoCAD SHX Text
AC.SHOP
AutoCAD SHX Text A0-3
AutoCAD SHX Text
COUNTING ROOM
AutoCAD SHX Text A0-10A
AutoCAD SHX Text
POLYSCAN
AutoCAD SHX Text A0-11A
AutoCAD SHX Text A0-23
AutoCAD SHX Text
COOLER
AutoCAD SHX Text A0-24
AutoCAD SHX Text
AUTOPSY
AutoCAD SHX Text
AO-30
AutoCAD SHX Text
HOUSE KEEPING
AutoCAD SHX Text A0-18
AutoCAD SHX Text
SPD
AutoCAD SHX Text D0-3
AutoCAD SHX Text
ELEC. RM.
AutoCAD SHX Text A0-11
AutoCAD SHX Text
FIRE ALARM
AutoCAD SHX Text A0-C3A
AutoCAD SHX Text
FEC
AutoCAD SHX Text A0-9
AutoCAD SHX Text
CLASS ROOM
AutoCAD SHX Text
BO-29
AutoCAD SHX Text
EQUIP. STO
AutoCAD SHX Text B0-18
AutoCAD SHX Text
TOILET
AutoCAD SHX Text D0-C1
AutoCAD SHX Text
ELEV. LOBBY
AutoCAD SHX Text D0-2
AutoCAD SHX Text
SERVICE LO
AutoCAD SHX Text D0-1
AutoCAD SHX Text
ELEV. MECH
AutoCAD SHX Text D0-2B
AutoCAD SHX Text P 6
AutoCAD SHX Text D0-2A
AutoCAD SHX Text P 7
AutoCAD SHX Text D0-C5
AutoCAD SHX Text
SECRETARY/
AutoCAD SHX Text B0-16
AutoCAD SHX Text
INVITRO LAB
AutoCAD SHX Text B0-16A
AutoCAD SHX Text
CHF.TECH.
AutoCAD SHX Text D0-C3
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text D0-22
AutoCAD SHX Text
H.R.LINKS
AutoCAD SHX Text D0-10
AutoCAD SHX Text
MRI
AutoCAD SHX Text D0-12
AutoCAD SHX Text H.A.C.
AutoCAD SHX Text D0-25
AutoCAD SHX Text
TOILET
AutoCAD SHX Text D0-48
AutoCAD SHX Text
PHYSICIAN
AutoCAD SHX Text D0-34
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text D0-33
AutoCAD SHX Text
RADIATION ONCOLOGY
AutoCAD SHX Text A0-1600
AutoCAD SHX Text
FISCAL SER
AutoCAD SHX Text 1,266.18
AutoCAD SHX Text A0-200
AutoCAD SHX Text I.R.M.
AutoCAD SHX Text A0-2400
AutoCAD SHX Text
MORGUE
AutoCAD SHX Text A0-1900
AutoCAD SHX Text
CANTEEN
AutoCAD SHX Text A0-1400
AutoCAD SHX Text
TRAVEL
AutoCAD SHX Text 509.20
AutoCAD SHX Text
BO-2200
AutoCAD SHX Text
AC.SHOP
AutoCAD SHX Text B0-2360
AutoCAD SHX Text
NEUROLOGY
AutoCAD SHX Text B0-1600
AutoCAD SHX Text
NUCLEARMED
AutoCAD SHX Text 8,259.25
AutoCAD SHX Text D0-21
AutoCAD SHX Text
RADIOLOGY
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
RADIOLOGY
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
PANEL
AutoCAD SHX Text A0-11
AutoCAD SHX Text
ACCESS TO UTILITIES ROOM
AutoCAD SHX Text
MEDICINE
AutoCAD SHX Text
SCHOOL OF NUCLEAR
AutoCAD SHX Text D0-33
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
PHARMACY
AutoCAD SHX Text D0-32
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
MEDICINE
AutoCAD SHX Text
NUCLEAR
AutoCAD SHX Text
ATTENDING PHYSICIAN
AutoCAD SHX Text
NUCLEAR MEDICINE
AutoCAD SHX Text
CHEIEF
AutoCAD SHX Text
DIGITAL SCANNER
AutoCAD SHX Text
THYROID LAB
AutoCAD SHX Text
UNION
AutoCAD SHX Text
NUCLEAR MEDICINE
AutoCAD SHX Text E0-7
AutoCAD SHX Text A0-18A
AutoCAD SHX Text
TRAVEL
AutoCAD SHX Text
TRAVEL
AutoCAD SHX Text
BENEFICIARY
AutoCAD SHX Text D0-15
AutoCAD SHX Text
DRESSING AREA
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text A0 C2
AutoCAD SHX Text
CLIMATE CONTROL
AutoCAD SHX Text A0-20C
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
TELECOMMUNICATION
AutoCAD SHX Text
EO-2
AutoCAD SHX Text
X-RAY # 1
AutoCAD SHX Text
EO-46
AutoCAD SHX Text
CARD
AutoCAD SHX Text
EO-32
AutoCAD SHX Text
PORTABLE
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
EO-51
AutoCAD SHX Text
BIOMED
AutoCAD SHX Text
EO-47A
AutoCAD SHX Text
NRSCAN
AutoCAD SHX Text
EO-1A
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
DARK ROOM
AutoCAD SHX Text
CARD READER
AutoCAD SHX Text
READER
AutoCAD SHX Text
EO-49
AutoCAD SHX Text
BIO MEDICAL
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
EO-48
AutoCAD SHX Text
EO-47
AutoCAD SHX Text
CHANGING
AutoCAD SHX Text
ROOMS
AutoCAD SHX Text
CHANGING
AutoCAD SHX Text
ROOMS
AutoCAD SHX Text
EXISTING AREAWAY
AutoCAD SHX Text
GENERATOR EQUIPMENT ROOM
AutoCAD SHX Text A0-12
AutoCAD SHX Text
GENERATOR ROOM
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text Affairs
AutoCAD SHX Text Date
AutoCAD SHX Text Project Number
AutoCAD SHX Text DRAWING No.
AutoCAD SHX Text Building Number
AutoCAD SHX Text Reviewed
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Const. Contract No.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Veterans
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Department of Veterans Affairs
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text By
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BC
AutoCAD SHX Text
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
REVISION DESCRIPTION
AutoCAD SHX Text
REVISION NO.
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
CONCRETE SHEAR WALL
AutoCAD SHX Text
SEE COVER SHEET FOR COORDINATION NOTES.
AutoCAD SHX Text Recommended Approvals:
AutoCAD SHX Text
1. MEDICAL DIRECTOR
AutoCAD SHX Text
6. OPERATIONS SERVICE LINE MANAGER
AutoCAD SHX Text
7. INFECTION CONTROL MANAGER
AutoCAD SHX Text
2. ASSOCIATE DIRECTOR
AutoCAD SHX Text
8. SAFETY MANAGER
AutoCAD SHX Text
3. CHIEF OF STAFF
AutoCAD SHX Text
4. ASSOC. DIRECTOR
AutoCAD SHX Text
9. GENERAL ENGINEER
AutoCAD SHX Text
5. SERVICE LINE MGRS.
AutoCAD SHX Text
10. COR
AutoCAD SHX Text Architect/Engineer Address
AutoCAD SHX Text
WWW.HARRELLDG.COM
AutoCAD SHX Text F 704.321.0833
AutoCAD SHX Text P 704.814.1320
AutoCAD SHX Text
CHARLOTTE, NC 28227
AutoCAD SHX Text
8016 TOWER POINT DRIVE
AutoCAD SHX Text
COPYRIGHT HARRELL DESIGN GROUP, PC
AutoCAD SHX Text c
AutoCAD SHX Text
AutoCAD SHX Text
HDG PROJECT # 17011
AutoCAD SHX Text
NO PIPING OR DUCTWORK SHALL BE ROUTED THROUGH ELECTRICAL AND/OR DATA ROOMS.
AutoCAD SHX Text HATCHING INDICATES AREAS OUTSIDE PRIMARY PROJECT LIMITS. SOME PROJECT LIMITS. SOME ACCESSORY WORK WILL OCCUR IN SHADED AREAS. REFER TO ALL DISCIPLINE DRAWINGS FOR COMPLETE SCOPE.
AutoCAD SHX Text
SYMBOL LEGEND
AutoCAD SHX Text
COORDINATION DRAWINGS
AutoCAD SHX Text
NORTHPORT VA MEDICAL CENTER
AutoCAD SHX Text
NORTHPORT, NY 11768
AutoCAD SHX Text
79 MIDDLEVILLE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL SHEET NOTES
AutoCAD SHX Text
KEYPLAN
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text
NW
AutoCAD SHX Text
SW
AutoCAD SHX Text
NE
AutoCAD SHX Text
SE
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
1-HOUR FIRE RATED WALL
AutoCAD SHX Text
NEW WALL
AutoCAD SHX Text EXISTING WALL, DOOR, WINDOW, MILLWORK, FIXTURE OR OTHER FIXTURE OR ASSEMBLY TO BE REMOVED..
AutoCAD SHX Text EXISTING WALL, DOOR, WINDOW, MILLWORK, FIXTURE OR OTHER FIXTURE OR ASSEMBLY TO REMAIN..
AutoCAD SHX Text
2-HOUR FIRE/SMOKE RATED WALL
AutoCAD SHX Text
SMOKE TIGHT WALL
AutoCAD SHX Text
3-HOUR FIRE/SMOKE RATED WALL
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
AutoCAD SHX Text 5'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text 3/32" = 1'-0"
AutoCAD SHX Text
BUILDING 200
AutoCAD SHX Text
LIFE SAFETY PLAN
AutoCAD SHX Text E2
AutoCAD SHX Text
GG
AutoCAD SHX Text
LK
AutoCAD SHX Text
LIFE SAFETY SYMBOL LEGEND
AutoCAD SHX Text
RE
AutoCAD SHX Text
FE
GRASS
ASPHALT
STORM
GRATE
(EXISTING)
STORM
GRATE
(EXISTING)
ELECTRICAL MH
GRASS
GRASS
GRASS
GRASS
WALK
WALK
WALK
WALK
WALK
CONCRETE
GRASS
ASPHALT
WALK
GRASS
GRASS
WALK
WALK
EXISTING
MH
(EXISTING)
SAN
MH
(EXISTING)
UPGRADE EMERGENCY
632-16-101
NOVEMBER 9, 2023
GENERATORS
H A R R E L L
DESIGN GROUP, PC
FULLY SPRINKLERED
BID DOCUMENTS
BUILDING 200 INTERIM
LIFE SAFETY PLAN
GI102
START OF TEMPORARY EGRESS ROUTE
DIRECTION OF TRAVEL
END OF TEMPORARY EGRESS ROUTE (EXIT)
PROVIDED EGRESS WIDTH
MINIMUM REQUIRED EGRESS WIDTH
EGRESS OCCUPANT LOAD
EXIT SIGN
OCCUPANT LOAD PER ROOM
ROOM AREA
## NET
### SQFT
## PEOPLE
NAME ROOM NAME
AREA PER OCCUPANT (NET OR GROSS)
X" REQ'D.
X" PROV'D.
# PEOPLE
FEC SEPARATION TRAVEL
COMMON PATH OF TRAVEL
REQUIRED EXIT
NEW ADDITION
CONSTRUCTION TYPE
II (2,2,2) SPECIAL
PURPOSE INDUSTRIAL
MAIN HOSPITAL
EXISTING HEALTHCARE
CONSTRUCTION TYPE II
(2,2,2)
CODE EDITIONS
NFPA 10 PORTABLE FIRE EXTINGUISHERS, 2018 EDITION
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2019 EDITION
NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS, 2019 EDITION NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2019 EDITION
NFPA 54 NATIONAL FUEL GAS CODE, 2018 EDITION
NFPA 70 NATIONAL ELECTRICAL CODE, 2020 EDITION
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2019 EDITION
NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2019 EDITION
NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2018 EDITION NFPA 90B STANDARD FOR THE INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS, 2018 EDITION NFPA 96 STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS, 2017 EDITION
NFPA 99 HEALTH CARE FACILITIES CODE, 2018 EDITION
NFPA 101 LIFE SAFETY CODE, 2018 EDITION
NFPA 105 STANDARD FOR SMOKE DOOR ASSEMBLIES AND OTHER OPENING PROTECTIVES, 2019 EDITION
NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS, 2019 EDITION
NFPA 241 STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2019 EDITION ASHRAE 90.1 ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS, 2016 EDITION
NFPA 220 STANDARD ON TYPES PF BUILDING CONSTRUCTION
NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE
EXISTING BUILDING TO
REMAIN
FIRE EXTINGUISHER MOUNTED ON WALL, W/ AMEREX
EXTINGUISHER BRACKET (TOP MAX. @ 3'6" AFF)
A. CONTRACTOR SHALL MAINTAIN UNOBSTRUCTED
EXISTS FOR EGRESS AND PROVIDE ALL REQUIRED
TEMPORARY SIGNAGE NECESSARY FOR EGRESS.
B. CONTRACTOR SHALL ENSURE FIRE ALARM,
DETECTION, AND SUPPRESSION SYSTEMS ARE
FUNCTIONING PROPERLY AND ARE NOT IMPAIRED.
WHEN CEILING IS REMOVED THE SPRINKLER HEADS
SHALL BE TURNED TO FACE UP DURING
CONSTRUCTION.
C. TEMPORARY CONSTRUCTION PARTITIONS SHALL BE
CONSTRUCTED TO MEET VA REQUIREMENTS FOR
1-HOUR FIRE SEPARATION BETWEEN CONSTRUCTION
AREA AND HOSPITAL. IN FULLY SPRINKLERED
FACILITIES THE 1-HOUR FIRE-RATED PARTITION MAY
TERMINATE AT THE CEILING.
D. CONTRACTOR SHALL PROVIDE ADDITIONAL
FIRE-FIGHTING EQUIPMENT AND USE TRAINING FOR
CONSTRUCTION PERSONNEL IN THE CONSTRUCTION
AREA.
E. CONTRACTOR SHALL PROVIDE A FIRE-WATCH FOR 9
MONTHS FROM THE START OF THE PROJECT SITE
WORK WHILE EXISTING EXIT IS BLOCKED AND NOT IN
USE.
NOT AN EXIT DURING
CONSTRUCTION
TEMPORARY CLOSURE
OR EXIT DURING
CONSTRUCTION OF
NEW GENERATOR
ADDITION AND
SITEWORK
TEMPORARILY COVER EXIT SIGN ON THIS
SIDE OF THE DOUBLE EGRESS DOORS
ITEMS REMAINING IN SERVICE DURING CONSTRUCTION REQUIRING CONTRACTOR PROTECTION:
1. LOADING DOCK ACCESS: EXISTING LOADING DOCK ACCESS ROAD MUST REMAIN IN SERVICE
DURING THE ENTIRE CONSTRUCTION PERIOD FOR THIS PROJECT. COVER EXCAVATIONS DAILY W/
1-1/4” THICK ASTM A36 STEEL ROAD PLATES CAPABLE OF SUPPORTING H-20 TRUCK LOADS.
PROVIDE TEMPORARY PROVISIONS INCLUDING STEEL ROAD PLATES, PHASED TRENCH WORK,
FLAGMEN, AND CAUTION SIGNAGE.
2. 15KVA PRIMARY DUCT BANK: EXISTING 15KVA PRIMARY DUCT BANK MUST REMAIN IN SERVICE, PROTECTED, AND UNDISTURBED DURING THE PROJECT'S ENTIRE CONSTRUCTION PERIOD. INSTALL
SHEETING AND SHORING ALONG DUCT BANK EDGES ADJACENT TO CONSTRUCTION.
3. UNDERGROUND UTILITIES: UNDERGROUND UTILITIES IN PLAN SOUTH AREA OF THE PROJECT
AREA SHALL REMAIN IN SERVICE FOR THE PROJECT DURATION, WITHOUT DISTURBANCE. ALL
REQUESTED MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL SHUTDOWNS SHALL BE
REQUESTED FROM, COORDINATED WTH, AND APPROVED BY THE VA-COR. SHUTDOWN REQUESTS
MUST PROVIDE WRITTEN PLAN DESCRIBING AFFECTED UTILITIES, DURATION, AND SAFETY
PRECAUTIONS (ACTIVITY HAZARD ANALYSES--SEE SPEC SECTION 013526). SUBMIT WRITTEN
SHUTDOWN REQUESTS TO VA-COR NOT LESS THAN 14 CALENDAR DAYS PRIOR TO THE REQUESTED
SHUTDOWN.
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text S
AutoCAD SHX Text
WALK
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text Affairs
AutoCAD SHX Text Date
AutoCAD SHX Text Project Number
AutoCAD SHX Text DRAWING No.
AutoCAD SHX Text Building Number
AutoCAD SHX Text Reviewed
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Const. Contract No.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Veterans
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Department of Veterans Affairs
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text Date
AutoCAD SHX Text By
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BC
AutoCAD SHX Text
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
REVISION DESCRIPTION
AutoCAD SHX Text
REVISION NO.
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
CONCRETE SHEAR WALL
AutoCAD SHX Text
SEE COVER SHEET FOR COORDINATION NOTES.
AutoCAD SHX Text Recommended Approvals:
AutoCAD SHX Text
1. MEDICAL DIRECTOR
AutoCAD SHX Text
6. OPERATIONS SERVICE LINE MANAGER
AutoCAD SHX Text
7. INFECTION CONTROL MANAGER
AutoCAD SHX Text
2. ASSOCIATE DIRECTOR
AutoCAD SHX Text
8. SAFETY MANAGER
AutoCAD SHX Text
3. CHIEF OF STAFF
AutoCAD SHX Text
4. ASSOC. DIRECTOR
AutoCAD SHX Text
9. GENERAL ENGINEER
AutoCAD SHX Text
5. SERVICE LINE MGRS.
AutoCAD SHX Text
10. COR
AutoCAD SHX Text Architect/Engineer Address
AutoCAD SHX Text
WWW.HARRELLDG.COM
AutoCAD SHX Text F 704.321.0833
AutoCAD SHX Text P 704.814.1320
AutoCAD SHX Text
CHARLOTTE, NC 28227
AutoCAD SHX Text
8016 TOWER POINT DRIVE
AutoCAD SHX Text
COPYRIGHT HARRELL DESIGN GROUP, PC
AutoCAD SHX Text c
AutoCAD SHX Text
AutoCAD SHX Text
HDG PROJECT # 17011
AutoCAD SHX Text
NO PIPING OR DUCTWORK SHALL BE ROUTED THROUGH ELECTRICAL AND/OR DATA ROOMS.
AutoCAD SHX Text HATCHING INDICATES AREAS OUTSIDE PRIMARY PROJECT LIMITS. SOME PROJECT LIMITS. SOME ACCESSORY WORK WILL OCCUR IN SHADED AREAS. REFER TO ALL DISCIPLINE DRAWINGS FOR COMPLETE SCOPE.
AutoCAD SHX Text
SYMBOL LEGEND
AutoCAD SHX Text
COORDINATION DRAWINGS
AutoCAD SHX Text
NORTHPORT VA MEDICAL CENTER
AutoCAD SHX Text
NORTHPORT, NY 11768
AutoCAD SHX Text
79 MIDDLEVILLE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL SHEET NOTES
AutoCAD SHX Text
KEYPLAN
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text
NW
AutoCAD SHX Text
SW
AutoCAD SHX Text
NE
AutoCAD SHX Text
SE
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
1-HOUR FIRE RATED WALL
AutoCAD SHX Text
NEW WALL
AutoCAD SHX Text EXISTING WALL, DOOR, WINDOW, MILLWORK, FIXTURE OR OTHER FIXTURE OR ASSEMBLY TO BE REMOVED..
AutoCAD SHX Text EXISTING WALL, DOOR, WINDOW, MILLWORK, FIXTURE OR OTHER FIXTURE OR ASSEMBLY TO REMAIN..
AutoCAD SHX Text
2-HOUR FIRE/SMOKE RATED WALL
AutoCAD SHX Text
SMOKE TIGHT WALL
AutoCAD SHX Text
3-HOUR FIRE/SMOKE RATED WALL
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text 64'
AutoCAD SHX Text 1/32" = 1'-0"
AutoCAD SHX Text
BUILDING 200
AutoCAD SHX Text
INTERIM LIFE SAFETY PLAN
AutoCAD SHX Text E2
AutoCAD SHX Text
MS
AutoCAD SHX Text
LK
AutoCAD SHX Text
LIFE SAFETY SYMBOL LEGEND
AutoCAD SHX Text
RE
AutoCAD SHX Text
FE
ELECTRICAL MH
GRASS
WALK
WALK
EXISTING
TEMPORARY
GENERATOR
LIMIT OF DISTURBANCE (BLDG)
LIMIT OF DISTURBANCE (BLDG)
LI
M
IT
O
F D
IS
TU
R B
A N
C E
(B
LD
G
LI
M
IT
O
F D
IS
TU
R B
A N
C E
(B
LD
G
UPGRADE EMERGENCY
632-16-101
NOVEMBER 9, 2023
GENERATORS
H A R R E L L
DESIGN GROUP, PC
FULLY SPRINKLERED
BID DOCUMENTS
ICRA PLAN
GC101
1. PROVIDE TEMPORARY 1-HR FIRE-RATED FULL
HEIGHT PARTITION AS INDICATED. PROVIDE 1-HR
RATED DOOR. FINISH AND PAINT ANY EXPOSED
SURFACE OF TEMPORARY WALLS TO THE PUBLIC.
2. CONSTRUCTION ENTRY/EXIT.
3. EXISTING DOORS LEADING TO HOSPITAL INTERIOR
TO BE CLOSED SHUT DURING CONSTRUCTION. GC
WILL HAVE LIMITED ACCESS OUTSIDE OF PROJECT
LIMITS. GC TO COORDINATE ANY ACCESS WITH COR
PRIOR TO THE START OF THE SCHEDULE.
4. PROVIDE PROTECTION AT PORTION OF AREAWAY
TO BE REMOVED/REPLACED DURING
CONSTRUCTION.
5. FOR SITE WORK EXTENTS, SEE CIVIL DRAWINGS.
A. REFER TO SHEET AD001 AND AD101 FOR
DEMOLITION NOTES.
B. MAINTAIN CORRIDOR WIDTHS AT SIX FEET.
C. GC TO PROVIDE TEMPORARY 1 HOUR
CONSTRUCTION PARTITIONS TO SEPARATE ALL
OCCUPIED AREAS FROM DEMOLITION AND
CONSTRUCTION. PARTITIONS SHALL BE 1-HOUR
FIRE-RATED FULL HEIGHT, EXTENDING THROUGH
SUSPENDED CEILINGS TO THE FLOOR SLAB OR
ROOF DECK. AS CONTRACTOR OPTION, IF
SPRINKLERS REMAIN OPERATIONAL ON BOTH SIDES
OF THE TEMPORARY 1 HOUR PARTITION, AND
SPRINKLER HEADS ARE ROTATED UPRIGHT IN THE
CONSTRUCTION AREA, THEN 1 HOUR PARTITION
MAY BE PERMITTED TO TERMINATE AT THE CEILING.
D. GC TO PROVIDE ADHESIVE/TACKY MAT FOR
INFECTION CONTROL. CHANGE MAT AT LEAST DAILY
AND MORE FREQUENTLY AS MAT GETS CLOGGED.
E. CONTRACTOR TO SEAL ALL EXISTING
PENETRATIONS IN EXISTING WALLS AT PERIMETER
OF PROJECT AREA. SEAL PENETRATIONS WITH FIRE
CAULK.
F. ANY DEMOLITION WORK DISRUPTING DAILY
OPERATION OF HOSPITAL MUST BE COORDINATED
WITH RESIDENT ENGINEER AND END USER AT LEAST
TWO WEEKS IN ADVANCE.
G. PROVIDE TEMPORARY 1-HOUR ANTEROOMS
SEPARATING CONSTRUCTION ZONES FROM
OCCUPIED AREAS. MINIMUM SIZE 4'-0" X 6'-0".
H. DO NOT CART CONSTRUCTION DEBRIS THROUGH
HOSPITAL. VACATE DEBRIS THROUGH ADJACENT
CONSTRUCTION AREAS, DIRECTLY TO THE OUTSIDE.
1. EXECUTE WORK BY METHODS TO MINIMIZE RAISING
DUST FROM CONSTRUCTION OPERATIONS.
2. IMMEDIATELY REPLACE A CEILING TILE DISPLACED FOR
VISUAL INSPECTION.
1. INCLUDES ALL ACTIVITIES REQUIRED BY CLASS I.
2. PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST
FROM DISPERSING INTO ATMOSPHERE.
3. WATER MIST WORK SURFACES TO CONTROL DUST
WHILE CUTTING.
4. SEAL UNUSED DOORS WITH DUCT TAPE.
5. BLOCK OFF AND SEAL SUPPLY AND RETURN AIR VENTS.
6. REPLACE ADHESIVE WALK-OFF MATS AT ENTRANCE AN
EXIT OF WORK AREA. REPLACE USED MATS IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS.
7. REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE
WORK IS BEING DONE TO PREVENT CONTAMINATION OF
DUCT SYSTEM.
1. INCLUDES ALL ACTIVITIES REQUIRED BY CLASS II.
2. OBTAIN INFECTION CONTROL PERMIT FROM HOSPITAL
SAFETY OFFICER OR FACILITIES MANAGEMENT
MAINTENANCE AND ENGINEERING DEPARTMENT
BEFORE CONSTRUCTION BEGINS.
3. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE
WORK IS BEING DONE TO PREVENT CONTAMINATION OF
DUCT SYSTEM.
4. COMPLETE ALL CRITICAL BARRIERS BEFORE
CONSTRUCTION BEGINS OR IMPLEMENT CONTROL CUBE
METHOD.
5. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA-EQUIPPED AIR FILTRATION UNITS.
6. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT
IN TIGHTLY COVERED CONTAINERS.
7. COVER TRANSPORT RECEPTACLES OR CARS. TAPE
COVERS.
8. WET MOP AND/OR VACUUM WITH HEPA FILTERED
VACUUM BEFORE LEAVING WORK AREAS.
9. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK IS BEING PERFORMED.
1. WIPE SURFACES TO REMOVE DUST.
1. WIPE WORK SURFACES WITH DISINFECTANT.
2. CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED CONTAINERS.
3. WET MOP AND/OR VACUUM WORK AREA WITH HEPA
FILTERED VACUUM BEFORE LEAVING WORK AREAS.
4. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS
WHERE WORK IS BEING PERFORMED.
1. REMOVE BARRIER MATERIALS CAREFULLY TO
MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
2. CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED CONTAINERS.
3. COVER TRANSPORT RECEPTACLES OR CARTS.
TAPE COVERING.
4. VACUUM WORK WITH HEPA-FILTERED VACUUMS.
5. WET MOP WITH DISINFECTANT.
6. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS
WHERE WORK IS BEING PERFORMED.
1. INCLUDES ALL ACTIVITIES REQUIRED BY CLASS III.
2. OBTAIN INFECTION CONTROL PERMIT FROM HOSPITAL
SAFETY OFFICER OR FACILITIES MANAGEMENT
MAINTENANCE AND ENGINEERING DEPARTMENT BEFORE
CONSTRUCTION BEGINS.
3. ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING
DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM.
4. COMPLETE ALL CRITICAL BARRIERS OR IMPLEMENT
CONTROL CUBE METHOD BEFORE CONSTRUCTION BEGINS.
5. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE
UTILIZING HEPA-EQUIPPED AIR FILTRATION UNITS.
6. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES
APPROPRIATELY. CONSTRUCT ANTEROOM AND REQUIRE
ALL PERSONNEL TO PASS-THROUGH THIS ROOM SO THEY
CAN BE VACUUMED USING A HEPA VACUUM CLEANER
BEFORE LEAVING WORK SITE OR THEY CAN WEAR CLOTH
OR PAPER COVERALLS THAT ARE REMOVED EACH TIME
THEY LEAVE THE WORK SITE.
7. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO
WEAR SHOE COVERS. SHOE COVERS MUST BE CHANGED
EACH TIME THE WORKER EXITS THE WORK AREA.
8. PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE TO WORK
AREA WITH ANTEROOM. REPLACE PER MANUFACTURER'S
RECOMMENDATIONS.
9. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL
COMPLETED PROJECT IS INSPECTED EACH BY THE
HOSPITAL SAFETY OFFICER, FACILITIES MANAGEMENT
MAINTENANCE AND ENGINEERING DEPARTMENT AND
THOROUGHLY CLEANED BY THE HOSPITAL ENVIRONMENTAL
SERVICES DEPARTMENT OR THEIR CONTRACTED
ENVIRONMENTAL SERVICES COMPANY.
10. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
11. COVER TRANSPORT RECEPTACLES OR CARS. TAPE
COVERING.
12. VACUUM WITH HEPA FILTERED VACUUM. WET MOP WITH
DISINFECTANT AFTER BARRIERS ARE REMOVED.
13. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK IS BEING PERFORMED.
1. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE
SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH
CONSTRUCTION.
2. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN
TIGHTLY COVERED CONTAINERS.
3. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE
COVERING.
4. VACUUM WORK WITH HEPA-FILTERED VACUUMS.
5. WET MOP WITH DISINFECTANT AFTER BARRIERS ARE
REMOVED.
6. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE
WORK WAS BEING PERFORMED.
DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE
FOLLOWING INFECTION CONTROL PRECAUTIONS DEPENDING UPON
THE AREA CLASS DESIGNATION
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE FOLLOWING INFECTION CONTROL PRECAUTIONS DEPENDING
UPON THE AREA CLASS DESIGNATION
CLASS I
CLASS II
CLASS III
CLASS IV
GROUP 1-LOW RISK
· OFFICE AREAS
(NON-CLINICAL)
PATIENT RISK GROUP TABLE
GROUP 2-MEDIUM RISK
· CARDIOLOGY
· ECHOCARDIOLOGY
· ENDOSCOPY-GI
· PHYSICAL THERAPY
· RADIOLOGY/MRI
· NUCLEAR MEDICINE
· RESPIRATORY CARE (EXCEPT
BRONCHOSCOPY AREA)
· CAFETERIA
· OUTPATIENT AREAS-CLINICS AND
OFFICES (EXCEPTION: TRANSPLANT AND
ONCOLOGY)
GROUP 3-HIGH RISK
· EMERGENCY ROOM
· POST ANESTHESIA
· CARE UNITS
· LABOR AND DELIVERY
· PEDIATRICS
· ADMISSION/DISCHARGE AREA
· LABORATORIES
· PHARMACY
· INPATIENT UNITS (NOT
OTHERWISE SPECIFIED)
GROUP 4-HIGHEST RISK
· ALL OPERATING ROOMS INCLUDING LABOR AND
DELIVERY
· ANESTHESIA AND PUMP AREAS
· CENTRAL EQUIPMENT/STERILE SUPPLY
· CARDIAC CATHETERIZATION AND ANGIOGRAPHY
AREAS
· INTERVENTIONAL RADIOLOGY
· RADIATION ONCOLOGY
· ALL INTENSIVE CARE UNITS
· NEWBORN NURSERIES, INCLUDING NICU
· DIALYSIS UNIT
· ONCOLOGY-INPATIENT AND OUTPATIENT
· TRANSPLANT-INPATIENT AND OUTPATIENT
· PHARMACY ADMIXTURE
· NEGATIVE PRESSURE ISOLATION ROOMS/AREAS
(INCLUDING BRONCHOSCOPY AREA)
INFECTION CONTROL MATRIX-CLASS OF PRECAUTIONS: CONSTRUCTION PROJECT BY PATIENT RISK
PATIENT RISK GROUP TYPE A TYPE B TYPE C TYPE D
LOW RISK GROUP 1 I II II III/IV
MEDIUM RISK GROUP 2 I II III IV
HIGH RISK GROUP 3 I III III/IV IV
HIGHEST RISK GROUP 4 III III/IV III/IV IV
NOTE: INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
INSPECTION AND NON-INVASIVE ACTIVITIES
INCLUDES BUT IS NOT LIMITED TO:
· REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO 1 TILE IN 50 SQUARE FEET
· PAINTING (BUT NOT SANDING), WALL COVERING
· ELECTRICAL TRIM WORK, MINOR PLUMBING, AND ACTIVITIES THAT DO NOT GENERATE DUST OR
REQUIRE CUTTING OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION
TYPE OF CONSTRUCTION/PROJECT ACTIVITY TABLE
TYPE A
SMALL SCALE, SHORT DURATION ACTIVITIES THAT CREATE MINIMAL DUST
INCLUDES BUT IS NOT LIMITED TO:
· INSTALLATION OF TELEPHONE AND COMPUTER CABLING
· ACCESS TO CHASE SPACES
· CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED
TYPE B
WORK THAT GENERATES A MODERATE TO HIGH LEVEL OF DUST OR REQUIRES DEMOLITION OR REMOVAL
OF ANY FIXED BUILDING COMPONENTS OR ASSEMBLIES
INCLUDES BUT IS NOT LIMITED TO:
· SANDING OF WALLS FOR PAINTING OR WALL COVERING
· REMOVAL OF FLOOR COVERINGS, CEILING TILES AND CASEWORK
· NEW WALL CONSTRUCTION
· MINOR DUCT WORK OR ELECTRICAL WORK ABOVE CEILINGS
· MAJOR CABLING ACTIVITIES
· ANY ACTIVITY THAT CANNOT BE COMPLETED WITHIN A SINGLE WORK SHIFT
TYPE C
MAJOR DEMOLITION AND CONSTRUCTION PROJECTS
INCLUDES BUT IS NOT LIMITED TO:
· ACTIVITIES THAT REQUIRE CONSECUTIVE WORK SHIFTS
· REQUIRES HEAVY DEMOLITION OR REMOVAL OF A COMPLETE CEILING SYSTEM
· NEW CONSTRUCTION
TYPE D
ICRA GENERAL NOTES
A. PROVIDE CONTAINMENT AS REQUIRED (BY HOSPITAL) INFECTION CONTROL REPRESENTATIVE FOR
WORK OUTSIDE MAJOR AREA.
B. PROVIDE CONTAINMENT AT THE FLOOR BELOW FOR ANY WORK IN THE CEILING PLENUM.
C. PROVIDE TEMPORARY DOOR WITH GASKETING TO PREVENT THE MOVEMENT OF DUST.
D. PROVIDE TEMPORARY EMERGENCY EXIT FROM CONSTRUCTION ZONE; HOWEVER, ALL GENERAL
CONSTRUCTION TRAFFIC SHOULD BE THROUGH VESTIBULE.
E. CONTRACTOR TO PROTECT ALL FINISHES INCLUDING (BUT NOT LIMITED TO) FLOORING, CEILING, WALL
SURFACES, DOORS, AND DOOR FRAMES DURING THE MOVEMENT OF MATERIALS TO/FROM LIMIT OF
WORK. COORDINATE WITH COR AND SPECIFICATIONS FOR PROCEDURES/REQUIREMENTS.
NOTE:
EXISTING BUILDINGS AND AREAS ADJACENT TO CONSTRUCTION REMAIN
OPERATIONAL AND OCCUPIED DURING ALL PHASES OF CONSTRUCTION.
ITEMS REMAINING IN SERVICE DURING CONSTRUCTION REQUIRING CONTRACTOR PROTECTION:
1. LOADING DOCK ACCESS: EXISTING LOADING DOCK ACCESS ROAD MUST REMAIN IN SERVICE
DURING THE ENTIRE CONSTRUCTION PERIOD FOR THIS PROJECT. COVER EXCAVATIONS DAILY W/
1-1/4” THICK ASTM A36 STEEL ROAD PLATES CAPABLE OF SUPPORTING H-20 TRUCK LOADS.
PROVIDE TEMPORARY PROVISIONS INCLUDING STEEL ROAD PLATES, PHASED TRENCH WORK,
FLAGMEN, AND CAUTION SIGNAGE.
2. 15KVA PRIMARY DUCT BANK: EXISTING 15KVA PRIMARY DUCT BANK MUST REMAIN IN SERVICE, PROTECTED, AND UNDISTURBED DURING THE PROJECT'S ENTIRE CONSTRUCTION PERIOD. INSTALL
SHEETING AND SHORING ALONG DUCT BANK EDGES ADJACENT TO CONSTRUCTION.
3. UNDERGROUND UTILITIES: UNDERGROUND UTILITIES IN PLAN SOUTH AREA OF THE PROJECT
AREA SHALL REMAIN IN SERVICE FOR THE PROJECT DURATION, WITHOUT DISTURBANCE. ALL
REQUESTED MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL SHUTDOWNS SHALL BE
REQUESTED FROM, COORDINATED WTH, AND APPROVED BY THE VA-COR. SHUTDOWN REQUESTS
MUST PROVIDE WRITTEN PLAN DESCRIBING AFFECTED UTILITIES, DURATION, AND SAFETY
PRECAUTIONS (ACTIVITY HAZARD ANALYSES--SEE SPEC SECTION 013526). SUBMIT WRITTEN
SHUTDOWN REQUESTS TO VA-COR NOT LESS THAN 14 CALENDAR DAYS PRIOR TO THE REQUESTED
SHUTDOWN.
DEDUCT ALTERNATE 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Q
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
SHFT. 5
AutoCAD SHX Text R.9
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text
DN
AutoCAD SHX Text
SWITCHGEAR
AutoCAD SHX Text D0-5
AutoCAD SHX Text
GENERATOR ROOM
AutoCAD SHX Text A0-11C
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text A0-C3B
AutoCAD SHX Text
ST. 5
AutoCAD SHX Text 148.75
AutoCAD SHX Text A0-C2
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text A0-11D
AutoCAD SHX Text
UTILITY
AutoCAD SHX Text D0-6
AutoCAD SHX Text
PUMP RM.
AutoCAD SHX Text D0-C2B
AutoCAD SHX Text
ST. 7
AutoCAD SHX Text D0-C2C
AutoCAD SHX Text
FEC
AutoCAD SHX Text A0-9A
AutoCAD SHX Text
CONSULTANT
AutoCAD SHX Text
AO-11B
AutoCAD SHX Text D0-4
AutoCAD SHX Text
ELEC.PANEL
AutoCAD SHX Text A0-11A
AutoCAD SHX Text
GENERATOR EQUIPMENT ROOM
AutoCAD SHX Text D0-3
AutoCAD SHX Text
ELEC. RM.
AutoCAD SHX Text A0-11
AutoCAD SHX Text
FIRE ALARM
AutoCAD SHX Text A0-C3A
AutoCAD SHX Text
FEC
AutoCAD SHX Text A0-9
AutoCAD SHX Text
CLASS ROOM
AutoCAD SHX Text D0-C5
AutoCAD SHX Text
SECRETARY/
AutoCAD SHX Text D0-11
AutoCAD SHX Text
TOILET
AutoCAD SHX Text D0-29
AutoCAD SHX Text
MRI CONSULTATION
AutoCAD SHX Text D0-C3
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text D0-22
AutoCAD SHX Text
H.R.LINKS
AutoCAD SHX Text D0-10
AutoCAD SHX Text
MRI
AutoCAD SHX Text D0-12
AutoCAD SHX Text H.A.C.
AutoCAD SHX Text D0-25
AutoCAD SHX Text
TOILET
AutoCAD SHX Text D0-48
AutoCAD SHX Text
PHYSICIAN
AutoCAD SHX Text D0-34
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text D0-35
AutoCAD SHX Text
PHYSICS
AutoCAD SHX Text D0-33
AutoCAD SHX Text
RADIATION ONCOLOGY
AutoCAD SHX Text D0-21
AutoCAD SHX Text D0-20
AutoCAD SHX Text
RADIOLOGY
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
RADIOLOGY
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
PANEL
AutoCAD SHX Text A0-11
AutoCAD SHX Text
ACCESS TO UTILITIES ROOM
AutoCAD SHX Text
MEDICINE
AutoCAD SHX Text
SCHOOL OF NUCLEAR
AutoCAD SHX Text D0-32
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
MEDICINE
AutoCAD SHX Text
NUCLEAR
AutoCAD SHX Text
ATTENDING PHYSICIAN
AutoCAD SHX Text
NUCLEAR MEDICINE
AutoCAD SHX Text D0-15
AutoCAD SHX Text
DRESSING AREA
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text A0 C2
AutoCAD SHX Text
CLIMATE CONTROL
AutoCAD SHX Text
CLIMATE CONTROL
AutoCAD SHX Text
EO-2
AutoCAD SHX Text
X-RAY # 1
AutoCAD SHX Text
EO-2A
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
EO-1A
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
DARK ROOM
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text Affairs
AutoCAD SHX Text Date
AutoCAD SHX Text Project Number
AutoCAD SHX Text DRAWING No.
AutoCAD SHX Text Building Number
AutoCAD SHX Text Reviewed
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Const. Contract No.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Veterans
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawn
AutoCAD SHX Text Checked
Auto…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .