S02 Mechanical Drawings.pdf

PDF 816 KB Posted

Attached to
Z1DA--528-16-112 BUFFALO VAMC ROOF REPLACEMENT
Solicitation number
36C24220B0053
Issued by

About this file

This document package includes mechanical drawings and specifications for roof replacement work at the Buffalo VA Medical Center in Buffalo, New York. The project involves fully replacing approximately 90,000 square feet of roofing across eight roof areas as depicted in the mechanical equipment plans. Bids for the roof replacement work will be solicited through solicitation number 36C24220B0053, with an estimated value between $1-5 million. The solicitation is expected to be posted on August 14, 2020 on SAM.gov and will be a 100% small business set-aside for NAICS code 238160, roofing contractors, with a size standard of $16.5 million. Site visits will be scheduled in advance of the bid due date, which has not yet been specified. Bid bonds will be required to respond. The contract is anticipated to be awarded on or around September 20, 2020, with only ancillary work possible in 2020 and full mobilization slated for March 15, 2021. All correspondence should be directed to the contracting officer via email.

View the file

Other files

File Type Posted
Asbestos Abatement Roof Schematic Report.pdf PDF
36C24220B0053 0001.docx DOCX document
Core Samples - Roof Schematic Report.pdf PDF
S02 Specs.pdf PDF
S02 Structural Drawings.pdf PDF
S02 Electrical Drawings.pdf PDF
S02 Hazardous Materials Drawings.pdf PDF
36C24220B0053_4.docx DOCX document
S02 Architectural Drawings.pdf PDF
S02 General Drawings.pdf PDF
S02 Plumbing Drawings.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10 6 2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 1

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-101

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC.

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EQUIPMENT TO REMAIN IN SERVICE. COORDINATE TEMPORARY SUPPORT WITH COR AS

NEEDED.

PROPOSED VENTILATOR TO BE INSTALLED BY OTHERS. COORDINATE FLASHING AND FINAL

LOCATION WITH COR.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

PENTHOUSE ROOF - CORE 1 1

UPPER 14TH FLOOR ROOF - CORE 1 1

14TH FLOOR ROOF EAST - CORE 1 1

14TH FLOOR ROOF SOUTH - CORE 1 1

14TH FLOOR ROOF WEST - CORE 1 1

14TH FLOOR ROOF NORTH - CORE 1 1

13TH FLOOR ROOF EAST - CORE 1 1

13TH FLOOR ROOF SOUTH - CORE 1 1

13TH FLOOR ROOF WEST - CORE 1 1

13TH FLOOR ROOF NORTH - CORE 1 1

12TH FLOOR ROOF SOUTH EAST - CORE 1 1

12TH FLOOR ROOF SOUTH WEST - CORE 1 1

12TH FLOOR ROOF NORTH WEST - CORE 1 1

12TH FLOOR ROOF NORTH EAST - CORE 1 1

DAYCARE BALCONY ROOF 1 1

PATIO ENTRANCE ROOF 1 1

EMPLOYEE ENTRANCE ROOF 1 1

NOTE: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

SCALE: 1/8"=1'-0"

ROOF AREA 11

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA

ROOF

AREA 8

11/14/2019

AIR CONDITIONING UNIT

EXHAUST DUCT

EXHAUST VENT

24 43

4 1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 2

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-102

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 21

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC.

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

AIR HANDLING UNIT TO REMAIN IN SERVICE. COORDINATE WITH COR.

COORDINATE EQUIPMENT REMOVAL WITH COR. OPENING TO BE CAPPED AND SEALED.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - D WING 1 2

10TH FLOOR ROOF - D WING 1 2

STAIRWELL ROOF - D WING 1 2

STAIRWELL ROOF - D WING 1 2

AMBULANCE ENTRANCE ROOF - D WING 1 2

AMBULANCE ENTRANCE ATRIUM - D WING 1 2

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AIR CONDITIONING UNIT (TYP)

AIR CONDITIONING EQUIPMENT WITH

CONDUIT/PIPING ON 9 LOOSE SUPPORTS EACH

AIR CONDITIONING UNIT

AIR CONDITIONING UNIT

EXHAUST DUCT

HVAC UNIT AND PIPING

WITH 20 LOOSE SUPPORTS EXHAUST DUCT

GLASS PANEL ROOF

EXHAUST DUCT

AIR CONDITIONING UNIT

38 42

HOODS ON 2 LOOSE SUPPORTS EACH

LOOSE SUPPORTED AIR CONDITIONING

EQUIPMENT WITH CONDUIT/PIPING ON

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 3

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-103

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 31

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EQUIPMENT TO REMAIN IN SERVICE. COORDINATE TEMPORARY SUPPORT WITH COR AS

NEEDED.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

TEMPORARILY SUPPORT DURING ROOFING ACTIVITIES. COORDINATE WITH COR.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

PENTHOUSE ROOF - E WING 1 3

2ND FLOOR ROOF - E WING 1 3

1ST FLOOR ROOF - E WING 1 3

PATIENT ENTRANCE ATRIUM - E WING 1 3

PATIENT ENTRANCE ROOF - E WING 1 3

NOTES: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 4

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-104

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 41

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EQUIPMENT STRUCTURE TO REMAIN IN PLACE AND OPERATIONAL. COORDINATE ACCESS

STAIR REMOVAL AND REPLACEMENT WITH COR.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

AIR HANDLING UNIT TO REMAIN IN SERVICE. COORDINATE WITH COR.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - A WING 1 4

10TH FLOOR ROOF - A WING 1 4

STAIRWELL ROOF - A WING 1 4

STAIRWELL ROOF - A WING 1 4

ENTRANCE ROOF - A WING 1 4

NOTE: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

UNKNOWN (TYP)

UNKNOWN (TYP)

UNKNOWN (TYP)

AIR CONDITIONING UNIT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 5

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-105

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 51

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

AIR HANDLING UNIT TO REMAIN IN SERVICE. COORDINATE WITH COR.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - B WING 1 5

10TH FLOOR ROOF - B WING 1 5

STAIRWELL ROOF - B WING 1 5

STAIRWELL ROOF - B WING 1 5

NOTE: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

GLASS PANEL ROOF

LOOSE SUPPORTED AIR

CONDITIONING EQUIPMENT

WITH CONDUIT/PIPING ON 4

LOOSE SUPPORTS

EXHAUST DUCT

AIR CONDITIONING UNIT

AIR CONDITIONING UNIT

EXHAUST DUCT

C

C

C

C

50 29

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 6

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-106

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 61

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC.

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EQUIPMENT TO REMAIN IN SERVICE. COORDINATE TEMPORARY SUPPORT WITH COR AS

NEEDED.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

AIR HANDLING UNIT TO REMAIN IN SERVICE. COORDINATE WITH COR.

REMOVE EQUIPMENT. COORDINATE REMOVAL WITH OTHER TRADES.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - C WING 1 6

10TH FLOOR ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

2ND FLOOR ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

LOADING DOCK ROOF 1 6

EMERGENCY GENERATOR & TANK ROOF - C WING 1 6

POLICE TRAINING ATRIUM 1 6

POLICE TRAINING GARAGE ROOF - C WING 1 6

NOTE: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

EXHAUST DUCT

DUCT ON 4 LOOSE

SUPPORTS

DUCT ON 4 LOOSE

SUPPORTS

PIPING

MECHANICAL EQUIPMENT

ON 7 LOOSE SUPPORTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 7

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-107

B1

528-17-S49

SBV CGR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 71

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC.

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EQUIPMENT TO REMAIN IN SERVICE. COORDINATE TEMPORARY SUPPORT WITH COR AS

NEEDED.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

AIR HANDLING UNIT TO REMAIN IN SERVICE. COORDINATE WITH COR.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

SPS ROOF 1 7

STAIRWELL ROOF 1 7

KITCHEN PENTHOUSE ROOFAREA 1 7

KITCHEN ROOF AREA 1 7

KITCHEN ROOF AREA 1 7

NOTE: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

EXISTING STONE BALLASTED

SINGLE PLY EPDM ROOFING

MEMBRANE OVER 6"

INSULATION ON METAL DECK

METAL SLAT ENCLOSURE WALL.

BOTTOM OF SLATS 12" ABOVE

ROOF TYP.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

MECHANICAL EQUIPMENT PLAN -

ROOF AREA 8

90% DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 M-108

B20, B28

528-17-S49

SBV CGR

GENERAL NOTES

1. REFER TO A-001 FOR NOTES AND LEGENDS.

2. RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC.

KEYED NOTES

VENTILATOR TO REMAIN IN SERVICE DURING ROOFING ACTIVITIES.

EXHAUST DUCT BREECHING TO REMAIN. REFLASH AS NECESSARY.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

HVAC CHILLER BUILDING ROOF 28 8

MEDICAL RESEARCH BUILDING ROOF 20 8

MEDICAL RESEARCH BUILDING STAIRWELL ROOF 20 8

MEDICAL RESEARCH BUILDING STAIRWELL ROOF 20 8

MEDICAL RESEARCH BUILDING ENTRANCE ROOF 20 8

MEDICAL RESEARCH BUILDING MECHANICAL ROOM ROOF 20 8

MEDICAL RESEARCH BUILDING PASSAGEWAY ROOF 20 8

NOTE: SEE AD502 FOR ROOF TYPE DETAILS AND DESCRIPTIONS.

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA 8

SCALE: 1/8"=1'-0"

ROOF AREA 81

LEGEND

NOT IN CONTRACT (NIC)

DWG-18271-M-101.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 1
Sheets and Views
DWG-18271-M-101.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 1
DWG-18271-M-102.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 2
Sheets and Views
DWG-18271-M-102.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 2
DWG-18271-M-103.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 3
Sheets and Views
DWG-18271-M-103.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 3
DWG-18271-M-104.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 4
Sheets and Views
DWG-18271-M-104.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 4
DWG-18271-M-105.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 5
Sheets and Views
DWG-18271-M-105.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 5
DWG-18271-M-106.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 6
Sheets and Views
DWG-18271-M-106.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 6
DWG-18271-M-107.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 7
Sheets and Views
DWG-18271-M-107.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 7
DWG-18271-M-108.REV0 MECHANICAL EQUIPMENT PLAN - ROOF AREA 8
Sheets and Views
DWG-18271-M-108.REVX MECHANICAL EQUIPMENT PLAN - ROOF AREA 8

File details come from the government source that posted it. Updated .