S02 Electrical Drawings.pdf

PDF 2 MB Posted

Attached to
Z1DA--528-16-112 BUFFALO VAMC ROOF REPLACEMENT
Solicitation number
36C24220B0053
Issued by

About this file

This pre-solicitation notice describes an upcoming roof replacement project at the Buffalo VA Medical Center. The Department of Veterans Affairs will issue solicitation 36C24220B0053 on or about August 14, 2020 seeking offers to replace approximately 90,000 square feet of roofing. The project value is estimated between $1,000,000 and $5,000,000. Offerors must be small businesses with average annual receipts less than $16.5 million, as the procurement is 100% set aside for small business under NAICS code 238160, roofing contractors. Ancillary work may commence before winter with full roof replacement scheduled from March 15, 2021. Interested parties should monitor beta.sam.gov for solicitation materials and amendments. Bids are due electronically by the time specified in the solicitation. Questions shall be directed to the contracting officer via email only.

View the file

Other files

File Type Posted
Asbestos Abatement Roof Schematic Report.pdf PDF
36C24220B0053 0001.docx DOCX document
Core Samples - Roof Schematic Report.pdf PDF
S02 Specs.pdf PDF
S02 Structural Drawings.pdf PDF
S02 Hazardous Materials Drawings.pdf PDF
36C24220B0053_4.docx DOCX document
S02 Mechanical Drawings.pdf PDF
S02 Architectural Drawings.pdf PDF
S02 General Drawings.pdf PDF
S02 Plumbing Drawings.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL NOTES & LEGEND CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13 E-001

B1, B20, B28

528-17-S49

JFF MAW

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

GENERAL SYMBOLS

ROOF DRAIN

VENT PIPE

RD

ELECTRONIC LOCK

MOTOR, SINGLE-PHASE

A

EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL ARROWS AND FACES AS SHOWN

SWITCH (# SUBSCRIPT AS INDICATED BELOW):

BLANK = SINGLE POLE 2 = DOUBLE POLE

3 = THREE-WAY 4 = FOUR-WAY

D = DIMMER K = KEY OPERATED

LV= LOW VOLTAGE P = WITH PILOT LIGHT

LM= LOW VOLTAGE MASTER RC= REMOTE CONTROL

PB= PUSH BUTTON STATION WP= WEATHER PROOF

T = TIMER OPERATED OS= OCCUPANCY SENSOR

M

CARD READER WITH KEYPAD; LETTER INDICATES AS FOLLOWS:

M=MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN

P-PEDESTAL R-RACK S-SURFACE W-WALL

M-MULLION

RECEPTACLE, DUPLEX

RECEPTACLE, DUPLEX ON EMERGENCY POWER

RECEPTACLE, DUPLEX W/ GROUND FAULT CIRCUIT INTERRUPTER

RECEPTACLE, QUADRAPLEX

RECEPTACLE, SINGLE

RECEPTACLE, SINGLE WITH SWITCH

RECEPTACLE, SPECIAL PURPOSE

A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R

B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R

C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R

D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R

E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R

F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R

G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-30R

H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R

RECEPTACLE, SWITCHED DUPLEX

DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE,

GROUNDING TYPE, 20A, W/ #12 CONDUCTORS IN FLEXIBLE

CORD (CENTERLINE OF OUTLET: 6'-6" AFF MIN)

RECEPTACLE, DUPLEX W/ GROUND FAULT CIRCUIT INTERRUPTER

ON EMERGENCY POWER

GFCI

S

S

GFCI

1. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH

BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED EQUIPMENT

GROUNDING CONDUCTOR.

2. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND

NORMAL BRANCH WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.

1. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES, CONDUITS,

ETC., SHOWN ON PLANS TO BE REMOVED, COMPLETELY REMOVE CONDUIT AND WIRING TO

THE OVERCURRENT PROTECTIVE DEVICE.

2. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT

PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING.

3. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS

PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.

GENERAL NOTES

GENERAL NOTES - DEMOLITION

AT LIGHTNING ROD GND GROUND CONDUCTOR

DEMOLITIONX X

E ELECTRIC

C RF/ELECTRICAL/COMMUNICATION CABLING

LADDER CABLE TRAYC C

LINE TYPES

VENTILATION HOOD WITH CURB

X ROOF LEGEND KEY

X KEYED NOTE

ROOF OR SMOKE HATCH

LIGHT FIXTURE, WALL MOUNTED, LETTER INDICATES TYPE.A

ALARM, HORN/VISUAL APPLIANCE ONE ASSEMBLY

E=EXISTING

F ALARM, FIRE, MANUAL, PULL STATION

SECURITY ACCESS, VIDEO CAMERA WITH LENS, ANGLE OF VIEW

LIGHTING WALL PACK - EXTERIOR BUILDING

11/14/2019

GND

GND

GND

GNDGNDGND

GN

D

GN

D

GN

D

GND GND GND

GND

GND

GND

GND

GND GND

AT AT AT

AT AT

AT

AT

AT

AT

AT

ATATATAT

ATATATAT

AT

AT AT

AT

AT

AT AT AT AT

AT

AT AT

GND

GND

GND

GND GN

D

GN

D

ELECTRICAL PLATFORM

ELECTRICAL EQUIPMENT

C

C

C

C C C

E

E

E

C

C

10 6 2

XXXXXXXX

X X

X X

X X

X X

X X X X X X X

X X

X X

X X

X X

X X

X X X

X X

X X

X X

X

LIGHTNING ROD (TYP)

X X

X

X

X

X

X X X X

XX

X X

X

X X

X

X X

X

X

X

X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF AREA 1

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED101

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF AREA 11

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. VARIOUS MECHANICAL EQUIPMENT WILL NEED TO BE DISCONNECTED TO ALLOW FOR ROOF

REPLACEMENT WORK. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE BUFFALO VAMC.

KEYED NOTES

REMOVE EXISTING LIGHTNING PROTECTION SYSTEM EQUIPMENT AND CONDUCTORS.

EXISTING DOWN CONDUCTORS TO REMAIN FOR REUSE.

REMOVE EXISTING ANTENNAS & ASSOCIATED CONDUIT TO ALLOW ROOF REPLACEMENT.

COORDINATE REMOVAL WITH DEVICE OWNER AND THE BUFFALO VAMC. REINSTALL ACTIVE

DEVICES FOLLOWING ROOF WORK.

RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO SUPPORT ROOF

REPLACEMENT. COORDINATE WORK WITH EQUIPMENT OWNER AND BUFFALO VAMC.

EXISTING LIGHTNING PROTECTION SYSTEM LOCATED ON TOP OF METAL EQUIPMENT

ENCLOSURES TO REMAIN. RECONNECT TO NEW LIGHTNING PROTECTION SYSTEM FOLLOWING

ROOF CONSTRUCTION.

CONDUIT FOR SOLAR PANELS TO BE REMOVED.

EXISTING COMMUNICATIONS WIRING TO BE REMOVED FROM SCUPPERS. SCUPPERS NOT TO

BE USED AS MEANS OF CABLE ROUTING.

EXISTING COMMUNICATIONS CABLING TO BE REMOVED FROM ACCESS DOOR FRAME. NEW

ROOF PENETRATIONS TO BE INSTALLED FOR CABLE ROUTING. ACCESS DOOR FRAME NOT TO

BE USED AS MEANS OF CABLE ROUTING.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

PENTHOUSE ROOF - CORE 1 1

UPPER 14TH FLOOR ROOF - CORE 1 1

14TH FLOOR ROOF EAST - CORE 1 1

14TH FLOOR ROOF SOUTH - CORE 1 1

14TH FLOOR ROOF WEST - CORE 1 1

14TH FLOOR ROOF NORTH - CORE 1 1

13TH FLOOR ROOF EAST - CORE 1 1

13TH FLOOR ROOF SOUTH - CORE 1 1

13TH FLOOR ROOF WEST - CORE 1 1

13TH FLOOR ROOF NORTH - CORE 1 1

12TH FLOOR ROOF SOUTH EAST - CORE 1 1

12TH FLOOR ROOF SOUTH WEST - CORE 1 1

12TH FLOOR ROOF NORTH WEST - CORE 1 1

12TH FLOOR ROOF NORTH EAST - CORE 1 1

DAYCARE BALCONY ROOF 1 1

PATIO ENTRANCE ROOF 1 1

EMPLOYEE ENTRANCE ROOF 1 1

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA

ROOF

AREA 8

AT AT

AT

AT

SOLAR PANEL (TYP)

AIR CONDITIONING UNIT

SOLAR PANEL (TYP)

E

E

E

E

E

E

E

E

E

EEEEEE

E

EE

E E

E E

24 43

LIGHTNING ROD (TYP)

360° 2

GND GND GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GNDGNDGNDGNDGNDGNDGNDGND

GND

GND

GND

GND

TO GROUND RISER

AT COLUMN 207

X X X X X X X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X

X

X

X

X

X X

X

X

X

X X X X X X X X X X X X X X X X X X X X X X

X X

X X

X X

X X

X4

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

XXXXXXXXXXXXXX

X X

X X

XXXXX

X

X X

X X

X X

X X

X X

X

X

X

X

X

X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF AREA 2

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED102

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF AREA 21

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. VARIOUS MECHANICAL EQUIPMENT WILL NEED TO BE DISCONNECTED TO ALLOW FOR ROOF

REPLACEMENT WORK. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE BUFFALO VAMC.

KEYED NOTES

REMOVE EXISTING LIGHTNING PROTECTION SYSTEM EQUIPMENT AND CONDUCTORS.

EXISTING SECURITY CAMERA. REMOVE AND REINSTALL FOLLOWING ROOF WORK.

COORDINATE REMOVAL WITH THE BUFFALO VAMC.

REMOVE ALL SOLAR PANELS, BRACKETS, STANDS, ASSOCIATED CONDUIT AND BOXES AND

OTHER ASSOCIATED EQUIPMENT AND DISPOSE OF IN ACCORDANCE TO PROJECT

SPECIFICATIONS.

CONDUIT FOR SOLAR PANELS TO BE REMOVED.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - D WING 1 2

10TH FLOOR ROOF - D WING 1 2

STAIRWELL ROOF - D WING 1 2

STAIRWELL ROOF - D WING 1 2

AMBULANCE ENTRANCE ROOF - D WING 1 2

AMBULANCE ENTRANCE ATRIUM - D WING 1 2

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

ATAT

AIR CONDITIONING UNIT

ELECTRICAL CABLE TRAY

ELECTRICAL CABLE TRAY

ANTENNA EQUIPMENT FRAMING

ANTENNA EQUIPMENT FRAMING

LIGHTNING ROD (TYP)

1 2

RD

RD

RD

RD

C

CCCCCCCCC

C

C

C

C C

C

C C

C

C

C

CCC

C C

C

C

C C

C C

C

RD

360°

GND GND GND

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GNDGNDGNDGNDGND

GND

GND

GND

GND

GND

GND

TO GROUND RISER

AT COLUMN 234

X X X X X X X X

X X

X X

X X

X X

X X

X X

X X

X X

X

XXXXXXXXXXXXXXX

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X

X

X

X

XX

X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF AREA 4

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED104

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF AREA 41

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. VARIOUS MECHANICAL EQUIPMENT WILL NEED TO BE DISCONNECTED TO ALLOW FOR ROOF

REPLACEMENT WORK. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE BUFFALO VAMC.

KEYED NOTES

REMOVE EXISTING LIGHTNING PROTECTION SYSTEM EQUIPMENT AND CONDUCTORS.

REMOVE EXISTING ANTENNAS & ASSOCIATED CONDUIT TO ALLOW ROOF REPLACEMENT.

COORDINATE REMOVAL WITH DEVICE OWNER AND THE BUFFALO VAMC. REINSTALL ACTIVE

DEVICES FOLLOWING ROOF WORK.

EXISTING SECURITY CAMERA. REMOVE AND REINSTALL FOLLOWING ROOF WORK.

COORDINATE REMOVAL WITH THE BUFFALO VAMC.

RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO WORK WITH

EQUIPMENT OWNER AND BUFFALO VAMC.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - A WING 1 4

10TH FLOOR ROOF - A WING 1 4

STAIRWELL ROOF - A WING 1 4

STAIRWELL ROOF - A WING 1 4

ENTRANCE ROOF - A WING 1 4

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AT

AT

GND

GND

GND

GND GND GND GND GND GND GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND GND GND UNKNOWN (TYP)

CONDUIT SUPPORT

(TYP)

UNKNOWN (TYP)

UNKNOWN (TYP)

AIR CONDITIONING UNIT

ANTENNA EQUIPMENT FRAMING

ANTENNA EQUIPMENT FRAMING

C

C

C C C C C C C

C

C

C

C

C

C C

C C

C

C

C

C

C

C

C

C

C

C

1 2

LIGHTNING ROD (TYP)

360°

X X

X X

X X

X X

X X X X X X X X X X X X X X X X X X X X X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X X X X X X X X X

TO GROUND RISER

AT COLUMN 228

X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF AREA 5

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED105

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF AREA 51

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. VARIOUS MECHANICAL EQUIPMENT WILL NEED TO BE DISCONNECTED TO ALLOW FOR ROOF

REPLACEMENT WORK. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE BUFFALO VAMC.

KEYED NOTES

REMOVE EXISTING LIGHTNING PROTECTION SYSTEM EQUIPMENT AND CONDUCTORS.

REMOVE EXISTING ANTENNAS & ASSOCIATED CONDUIT TO ALLOW ROOF REPLACEMENT

COORDINATE WITH DEVICE OWNER AND THE BUFFALO VAMC. REINSTALL ACTIVE DEVICES

FOLLOWING ROOF WORK.

EXISTING SECURITY CAMERA. REMOVE AND REINSTALL FOLLOWING ROOF WORK.

COORDINATE REMOVAL WITH THE BUFFALO VAMC.

RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO WORK WITH

EQUIPMENT OWNER AND BUFFALO VAMC.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - B WING 1 5

10TH FLOOR ROOF - B WING 1 5

STAIRWELL ROOF - B WING 1 5

STAIRWELL ROOF - B WING 1 5

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AT

AT

GND

GND

GND

GND

GND

GND GND GND GND GND GND

GND

GND

GND

GND

GND

GND

GNDGNDGND

GLASS PANEL ROOF

ANTENNA EQUIPMENT FRAMING

AIR CONDITIONING EQUIPMENT

AIR CONDITIONING UNIT

AIR CONDITIONING UNIT

ELECTRICAL CABLE TRAY

ELECTRICAL CONDUITS

AND SUPPORTS

ANTENNA EQUIPMENT FRAMING

ELECTRICAL EQUIPMENT PLATFORM

C

C

C

C

C C C C C C C C

C

C

C C

C C

C

C C

C

C

C

50 29

1 2

LIGHTNING ROD

(TYP)

X X

X X

X X

X

X X X X X X X X X X X X X X X X X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

XXXXXXXXX

X

X

X

X

X

X

X

X

TO GROUND RISER

AT COLUMN 218

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF AREA 6

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED106

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF AREA 61

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. VARIOUS MECHANICAL EQUIPMENT WILL NEED TO BE DISCONNECTED TO ALLOW FOR ROOF

REPLACEMENT WORK. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE BUFFALO VAMC.

KEYED NOTES

REMOVE EXISTING LIGHTNING PROTECTION SYSTEM EQUIPMENT AND CONDUCTORS.

REMOVE EXISTING ANTENNAS & ASSOCIATED CONDUIT TO ALLOW ROOF REPLACEMENT.

COORDINATE REMOVAL WITH DEVICE OWNER AND THE BUFFALO VAMC. REINSTALL ACTIVE

DEVICES FOLLOWING ROOF WORK.

RELOCATE OR REMOVE AND REINSTALL EXISTING CABLING AS NEEDED TO WORK WITH

EQUIPMENT OWNER AND BUFFALO VAMC.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - C WING 1 6

10TH FLOOR ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

2ND FLOOR ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

LOADING DOCK ROOF 1 6

EMERGENCY GENERATOR & TANK ROOF - C WING 1 6

POLICE TRAINING ATRIUM 1 6

POLICE TRAINING GARAGE ROOF - C WING 1 6

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

E E

E

RD

RD

RD

RD

RDRDRDRD

RD

RD RD RD RD

RD

RD

RD

ELECTRICAL EQUIPMENT

AT AT AT AT AT AT AT AT AT

AT AT

ATAT

AT

AT

AT AT

AT

AT AT

ATAT

AT AT

ATAT

AT

AT AT

AT AT

AT

AT AT AT

AT AT

ATAT

AT

ATATATATATATATATATATAT

AT

ATAT

ATAT AT

AT AT

GN

D

GN

D

GND GND

GND

GND

GN

D

GND GND

GN

D

GND

GND

GND GND

GN

D

GN

D

GND GND

AT

AT AT

AT

AT

2 2

GNDGN

DATAT AT

AT AT

ATAT

X X

X X X X X X

X X

X X

0°

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF AREA 8

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED108

B20, B28

528-17-S49

SBV CJR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 81

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. VARIOUS MECHANICAL EQUIPMENT WILL NEED TO BE DISCONNECTED TO ALLOW FOR ROOF

REPLACEMENT WORK. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE BUFFALO VAMC.

4. SEE SPECIFICATION 264100 FOR ADDITIONAL REQUIREMENTS.

5. EXISTING AIR TERMINAL LOCATIONS ARE SHOWN FOR REFERENCE ONLY. ACTUAL QUANTITY

AND LOCATION MAY VARY FROM THAT SHOWN.

6. CONTRACTOR TO PROVIDE DIMENSIONED AS - LEFT DRAWING OF LIGHTNING PROTECTION

SYSTEM.

KEYED NOTES

REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AS NEEDED TO SUPPORT ROOF

REPLACEMENT. REINSTALL FOLLOWING ROOF REPLACEMENT, REPLACE ANY PARTS FOUND

TO BE PAST THEIR USEFUL SERVICE LIFE. IF ANY AREA IS FOUND TO BE DEFICIENT UPON

INSPECTION, PROVIDE ADDITIONAL LIGHTENING PROTECTION AS NEEDED.

LIGHTNING PROTECTION SYSTEM DOWN CONDUCTOR PROTECT DURING ROOF

REPLACEMENT.

REMOVE AND REPLACE SECURITY CAMERA AND ASSOCIATED CONDUIT AND WIRE AS NEEDED

TO SUPPORT ROOF REPLACEMENT.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

HVAC CHILLER BUILDING ROOF 28 8

MEDICAL RESEARCH BUILDING ROOF 20 8

MEDICAL RESEARCH BUILDING STAIRWELL ROOF 20 8

MEDICAL RESEARCH BUILDING STAIRWELL ROOF 20 8

MEDICAL RESEARCH BUILDING ENTRANCE ROOF 20 8

MEDICAL RESEARCH BUILDING MECHANICAL ROOM

ROOF 20 8

MEDICAL RESEARCH BUILDING PASSAGEWAY ROOF 20 8

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA 8

LEGEND

NOT IN CONTRACT (NIC)

SOLARIUM

ANNEX A

T

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF 49

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED401

B1

528-17-S49

JFF MAW

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/2"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF 491

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA 8

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. ALL EQUIPMENT IN ROOM 107 IS TO BE REMOVED TO SUPPORT DEMOLITION ACTIVITIES. NOT

ALL EQUIPMENT MAY BE SHOWN ON DRAWING.

KEYED NOTES

SAVE ELECTRONIC DOOR LOCK HARDWARE AND TURN OVER TO VA COR.

SAVE EXISTING CAMERAS AND TURN OVER TO VA COR.

EXISTING HVAC EQUIPMENT. COORDINATE REMOVAL WITH MECHANICAL CONTRACTOR.

PATCH/REPAIR ALL EXISTING HOLES IN WALL SEPARATING ROOMS 107 AND 106 THROUGH

WHICH WIRING, CONDUIT, ETC. PASSES.

OS

A

A

A

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL DEMOLITION PLAN -

ROOF 44

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

ED402

B1

528-17-S49

SBV CJR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA 8

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. PROTECT EXISTING DEVICE TO REMAIN DURING CONSTRUCTION.

KEYED NOTES

REMOVE EXISTING POWER SLIDING DOORS; EXISTING POWER WIRING TO BE REUSED FOR

NEW DOORS.

REMOVE FIXTURE AND ASSOCIATED PHOTOEYE SENSOR. REMOVE ASSOCIATED CIRCUIT

BACK TO SWITCH.

REMOVE EXISTING LIGHT FIXTURE. ASSOCIATED WIRING TO BE REMOVED BACK TO SWITCH.

SCALE: 3/4"=1'-0"

ELECTRICAL DEMOLITION PLAN - ROOF 441

GNDGN

D

GND

GND

GND

GND GND GND

GND

GND

GND

GNDGNDGND

ELECTRICAL PLATFORM

ELECTRICAL EQUIPMENT

10 6 2

LIGHTNING ROD (TYP)

AT

AT

AT

AT AT

ATAT

AT

AT AT

1'- 0"

(T

YP

1'-0"

(TYP)

AT

GN

D

ATAT AT

ATAT AT AT

ATAT

ATAT

GND

GN

DGND

GN

D

GND GN

D

'-2

" T

YP

1 2

GN

D

GN

D

GN

D

EXISTING

WARNING

LIGHTS

AT

AT

ATAT

APPROXIMATE

LOCATION OF

COLUMN

APPROXIMATE

LOCATION OF

COLUMN

APPROXIMATE

LOCATION OF

COLUMN

APPROXIMATE

LOCATION OF

COLUMN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL LIGHTNING

PROTECTION PLAN - ROOF AREA 1

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EG101

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 11

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. ALL GROUND WIRE SHALL BE MINIMUM #4/0 AWG BARE COPPER WIRING

4. SEE SPECIFICATION 264100 FOR ADDITIONAL REQUIREMENTS.

5. CONNECT ALL ANTENNAS TO LIGHTNING PROTECTION SYSTEM.

KEYED NOTES

TO GROUND RISER AT COLUMN 218

TO GROUND RISER AT COLUMN 207

TO GROUND RISER AT COLUMN 228 (NEW #4/0 AWG GROUND CONDUCTOR)

TO GROUND RISER AT COLUMN 234 (NEW #4/0 AWG GROUND CONDUCTOR)

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

PENTHOUSE ROOF - CORE 1 1

UPPER 14TH FLOOR ROOF - CORE 1 1

14TH FLOOR ROOF EAST - CORE 1 1

14TH FLOOR ROOF SOUTH - CORE 1 1

14TH FLOOR ROOF WEST - CORE 1 1

14TH FLOOR ROOF NORTH - CORE 1 1

13TH FLOOR ROOF EAST - CORE 1 1

13TH FLOOR ROOF SOUTH - CORE 1 1

13TH FLOOR ROOF WEST - CORE 1 1

13TH FLOOR ROOF NORTH - CORE 1 1

12TH FLOOR ROOF SOUTH EAST - CORE 1 1

12TH FLOOR ROOF SOUTH WEST - CORE 1 1

12TH FLOOR ROOF NORTH WEST - CORE 1 1

12TH FLOOR ROOF NORTH EAST - CORE 1 1

DAYCARE BALCONY ROOF 1 1

PATIO ENTRANCE ROOF 1 1

EMPLOYEE ENTRANCE ROOF 1 1

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA

ROOF

AIR CONDITIONING UNIT

24 43

LIGHTNING ROD (TYP)

360°

GND

GND

GND

GND

GND

GN

D

GND

GND

GND

GND

GND GND GND

GND

GND

GND

GND

GND

GND

GND GND GND GND GND GND

GN

D

GN

D

GN

D

GNDGNDGNDGNDGNDGNDGND

GND

GND

GND

AT

AT

AT

ATAT

AT AT

AT

AT

AT

AT

AT

AT AT

AT

AT AT

ATAT

ATATAT

AT

AT

AT

AT

ATAT

GND

'-0

" T

YP

5 GND

ATATAT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL LIGHTNING

PROTECTION PLAN - ROOF AREA 2

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EG102

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 21

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. ALL GROUND WIRE SHALL BE MINIMUM #4/0 AWG BARE COPPER WIRING

4. SEE SPECIFICATION 264100 FOR ADDITIONAL REQUIREMENTS.

KEYED NOTES

REINSTALL EXISTING CAMERAS, CONNECT TO NEW LIGHTNING PROTECTION SYSTEM.

NOT USED

PROVIDE NEW #4/0 AWG DOWN CONDUCTOR TO GROUND.

TO GROUND RISER AT COLUMN 207 (EXISTING #4/0 AWG GROUND CONDUCTOR). SEE EG101

FOR COLUMN LOCATION.

TO GROUND RISER AT COLUMN 234 (NEW #4/0 AWG GROUND CONDUCTOR) SEE EG101 FOR

COLUMN LOCATION.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - D WING 1 2

10TH FLOOR ROOF - D WING 1 2

STAIRWELL ROOF - D WING 1 2

STAIRWELL ROOF - D WING 1 2

AMBULANCE ENTRANCE ROOF - D WING 1 2

AMBULANCE ENTRANCE ATRIUM - D WING 1 2

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AIR CONDITIONING UNIT

ELECTRICAL

CABLE TRAY

ELECTRICAL CABLE TRAY

ANTENNA EQUIPMENT FRAMING

ANTENNA

EQUIPMENT

FRAMING

LIGHTNING ROD (TYP)

RD

RD

RD

RD

RD

360°

GND GND GND

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GND GND GND GND GND

GN

D

GN

D

GNDGNDGNDGNDGNDGNDGND

GND

GND

GND

GN

D

GN

D

GND

GND

GND

GN

D

GN

D

GN

D

AT

AT

AT

AT AT ATAT AT

AT

AT AT

ATAT

ATATAT

AT

AT

AT

AT

ATATAT

AT

ATAT

AT

AT

GN

D

AT AT

ATAT

GND

GND

GND

GND

'-0

" T

YP

GND

GNDGND

GN

D

AT AT AT

ATATAT

GND

GND

AT

AT

AT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL LIGHTNING

PROTECTION PLAN - ROOF AREA 4

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EG104

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 41

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. ALL GROUND WIRE SHALL BE MINIMUM #4/0 AWG BARE COPPER WIRING

4. SEE SPECIFICATION 264100 FOR ADDITIONAL REQUIREMENTS.

KEYED NOTES

REINSTALL EXISTING CAMERAS, CONNECT TO NEW LIGHTNING PROTECTION SYSTEM.

PROVIDE GROUND CONNECTIONS TO ROOF MOUNTED EQUIPMENT.

PROVIDE NEW #4/0 AWG DOWN CONDUCTOR TO GROUND.

TO GROUND RISER AT COLUMN 228 (NEW #4/0 AWG GROUND CONDUCTOR) SEE EG101 FOR

COLUMN LOCATION.

TO GROUND RISER AT COLUMN 234 (EXISTING #4/0 AWG GROUND CONDUCTOR) SEE EG101

FOR COLUMN LOCATION.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - A WING 1 4

10TH FLOOR ROOF - A WING 1 4

STAIRWELL ROOF - A WING 1 4

STAIRWELL ROOF - A WING 1 4

ENTRANCE ROOF - A WING 1 4

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

UNKNOWN (TYP)

CONDUIT SUPPORT

(TYP)

UNKNOWN (TYP)

UNKNOWN (TYP)

AIR CONDITIONING UNIT

ANTENNA EQUIPMENT FRAMING

ANTENNA EQUIPMENT FRAMING

LIGHTNING ROD (TYP)

360°

GND

GND

GND

GND GND GND GND GND GND

GND

GND

GND

GND

GND

GND GND

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GN

D

GND

GND

GND

GNDGND

GND

GND

GN

D

GNDGNDGNDAT

AT

AT AT AT

AT

AT

AT

AT

AT AT

ATAT

AT AT

AT

AT

AT

AT

AT

AT

AT

ATAT

AT

ATAT

AT

ATAT

AT

GND

GND

'-0

" T

YP

GND 2

GND

GND

GND

GND

GND

3 20'-0" TYP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL LIGHTNING

PROTECTION PLAN - ROOF AREA 5

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EG105

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 51

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. ALL GROUND WIRE SHALL BE MINIMUM #4/0 AWG BARE COPPER WIRING

4. SEE SPECIFICATION 264100 FOR ADDITIONAL REQUIREMENTS.

KEYED NOTES

REINSTALL EXISTING CAMERAS, CONNECT TO NEW LIGHTNING PROTECTION SYSTEM.

PROVIDE GROUND CONNECTIONS TO ROOF MOUNTED EQUIPMENT.

PROVIDE NEW #4/0 AWG DOWN CONDUCTOR TO GROUND.

TO GROUND RISER AT COLUMN 218 (NEW #4/0 AWG GROUND CONDUCTOR) SEE EG101 FOR

COLUMN LOCATION.

TO GROUND RISER AT COLUMN 228 (EXISTING #4/0 AWG GROUND CONDUCTOR) SEE EG101

FOR COLUMN LOCATION.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - B WING 1 5

10TH FLOOR ROOF - B WING 1 5

STAIRWELL ROOF - B WING 1 5

STAIRWELL ROOF - B WING 1 5

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

ANTENNA EQUIPMENT FRAMING

AIR CONDITIONING EQUIPMENT

AIR CONDITIONING UNIT

AIR CONDITIONING UNIT

ELECTRICAL

CABLE TRAY

ELECTRICAL CONDUITS

AND SUPPORTS

ANTENNA EQUIPMENT FRAMING

ELECTRICAL

EQUIPMENT

PLATFORM

C

C

C

C

50 29

LIGHTNING ROD

(TYP)

GNDGNDGNDGNDGNDGND

GND

GND

GND

GND GND GND

GN

D

GND

GND

GND GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GNDGND

GND

GND

GND

GND

GND

GND

AT

AT

AT AT AT

AT

AT AT

AT

AT AT

AT

AT

AT

AT

AT

AT

AT

AT

ATAT

AT

ATAT

AT

AT

AT

AT

ATATAT

GND

GND

'-0

" T

YP

GND

AT AT

ATAT

GND GN

D

GND

GND

GND

GND

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL LIGHTNING

PROTECTION PLAN - ROOF AREA 6

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EG106

B1

528-17-S49

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: 1/8"=1'-0"

ROOF AREA 61

JFF MAW

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

2. COORDINATE ALL ROOF WORK WITH THE BUFFALO VAMC. CERTAIN AREAS WILL REQUIRE

SHUTTING DOWN RADIO TRANSMISSION EQUIPMENT OWNED BY OTHERS. COORDINATE ALL

SHUTDOWN WORK WITH EQUIPMENT OWNERS.

3. ALL GROUND WIRE SHALL BE MINIMUM #4/0 AWG BARE COPPER WIRING

4. SEE SPECIFICATION 264100 FOR ADDITIONAL REQUIREMENTS.

KEYED NOTES

REINSTALL EXISTING CAMERAS, CONNECT TO NEW LIGHTNING PROTECTION SYSTEM.

PROVIDE GROUND CONNECTIONS TO ROOF MOUNTED EQUIPMENT.

PROVIDE NEW #4/0 AWG DOWN CONDUCTOR TO GROUND.

TO GROUND RISER AT COLUMN 207 (NEW #4/0 AWG GROUND CONDUCTOR) SEE EG101 FOR

COLUMN LOCATION.

TO GROUND RISER AT COLUMN 218 (EXISTING #4/0 AWG GROUND CONDUCTOR) SEE EG101

FOR COLUMN LOCATION.

ROOF LEGEND

KEY DESCRIPTION BUILDING ROOF AREA

11TH FLOOR ROOF - C WING 1 6

10TH FLOOR ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

2ND FLOOR ROOF - C WING 1 6

STAIRWELL ROOF - C WING 1 6

LOADING DOCK ROOF 1 6

EMERGENCY GENERATOR & TANK ROOF - C WING 1 6

NOT USED 1 6

POLICE TRAINING GARAGE ROOF - C WING 1 6

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

NOTES:

1. MAINTAIN A MINIMUM CLEARANCE OF 12" ON ALL SIDES OF ROOF PENETRATION

FROM WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER

FLASHING.

2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.

3. VERIFY ROOF AND STRUCTURAL SYSTEM WITH ARCHITECT.

4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO

ENSURE PROPER METHODS AND MATERIALS ARE USED TO MAINTAIN ROOF

WARRANTY.

ROOF MEMBRANE

SEALANT AT

PENETRATION TO

MEMBRANE JUNCTURE

BY ROOFING

CONTRACTOR

PREFABRICATED RUBBER

BOOT CAMP WITH

GRADUATED STEPS AND

WEATHER-PROOF

PRESSURE SEAL TO

COLLAR

STAINLESS CLAMP, TYP

SEAL-OFF

FITTING,

TYP

CONDUIT, TYP

BATT INSULATION

PREFABRICATED FORMED 0.06"

THICK ALUMINUM FLASHING

ROUND COLLAR WITH MIN 3" WIDE

FLANGE. ATTACH TO ROOF PER

MANUFACTURERS INSTRUCTIONS

MULTIPLE MEMBRANE STRIPPING

PLIES FEATHERED AT FIELD OF

ROOF BY ROOFING CONTRACTOR.

PRIME FLANGE BEFORE STRIPPING

STEEL

EXPANSION

ANCHOR

3/8" MIN GALVANIZED

THREADED ROD, TYP

LOCKING SQUARE

WASHER AND

LOCKNUT

INTEGRAL GALVANIZED

LIPPED STEEL

MOUNTING CHANNEL

CONDUIT CLAMP,

SIZE AS REQUIRED

ROOF

WATER CUT-OFF

MASTIC COMPATIBLE

WITH ROOF

MEMBRANE

CONDUIT CLAMP,

SIZE AS REQUIRED

TYPICAL PARAPET AIR TERMINAL

TYPICAL TOP MOUNT AIR TERMINAL

TYPICAL TRI-POD MID-ROOF AIR

TERMINAL

TYPICAL MID-ROOF AIR TERMINAL

TYPICAL AIR TERMINAL PLACEMENT

AT OUTSIDE CORNERS

POINT TO EXTEND A MINIMUM

OF 10” ABOVE TOP OF PARAPET

CABLE FASTENER

POINT BASE

POINT

ADHESIVE TYPE

CABLE HOLDER

ADHESIVE TYPE POINT BASE

POINT

LOOP TYPE MASONRY

CABLE ANCHOR

POINT BASE

2’ - 0” MAX

POINT (>24” HIGH)

ADHESIVE TYPE

TRIPOD HOLDER

ADHESIVE TYPE

CABLE HOLDER

ADHESIVE TYPE POINT BASE

TYPICAL FLASHING BOND

TYPICAL METALLIC WATER PIPE

BONDING CLAMP

TYPICAL ROOF DRAIN BOND TYPICAL CABLE SPLICERS

SECONDARY BONDING WIRE

CAST TERMINAL BONDING LUG.

SECURE WITH STAINLESS STEEL

MACHINE SCREW AND NUT

MAIN SIZE CONDUCTOR

CAST PIPE BONDING CLAMP

MAIN SIZE CONDUCTOR

ADJUSTABLE PIPE

BONDING STRAP

CAST PARALLEL

COMBINATION CABLE

SPLICER

CAST “TEE”

TYPE CABLE

SPLICER

CAST BRONZE TO ALUMINUM

BIMETALLIC CABLE SPLICER

SECONDARY

BONDING WIRE

SECONDARY

BONDING WIRE

ROOF SYSTEM

ROXTEC OR

EQUIVALENT

TRANSIT SYSTEM

EXISTING CABLES

(QTY AS REQUIRED)

SEALING

COMPONANT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL LIGHTNING DETAILS CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EG501

B1,B20, B28

528-17-S49

JFF MAW

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

SCALE: NTS

CONDUIT ROOF PENETRATION DETAIL1 SCALE: NTS

LIGHTNING PROTECTION SYSTEM DETAILS2 SCALE: 3

CABLE ROOF PENETRATION DETAIL3

OS

A

F

B

A A

EP201

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL POWER PLAN -

ROOF 44

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EP101

B1

528-17-S49

SBV CJR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA 8

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

KEYED NOTES

CONNECT TO EXISTING AREA LIGHTING CIRCUIT.

NEW POWER SLIDING DOORS TO BE CONNECTED TO EXISTING POWER DOOR CIRCUIT.

CONNECT TO EXISTING AREA RECEPTACLE CIRCUIT.

SCALE: 1/2"=1'-0"

ELECTRICAL POWER PLAN - ROOF 441

LIGHTING FIXTURE SCHEDULE

MARK DESCRIPTION

LAMPS

LENS FINISH MOUNTING BASIS OF DESIGN NOTES

TYPE VOLTS WATTS

A 1'X4' LED SUSPENDED LIGHT FIXTURE 3800 LUMEN,

4000K COLOR TEMPERATURE, MIN 80 CRI LED UNV (120-277V) 30 ACRYLIC

DIFFUSER

STANDARD

WHITE

SUSPENDED 10' ABOVE

FINISHED FLOOR

SIGNIFY SONA

7711LAEAG047DSWN

B 1'X1'X6" LED WALLPACK, 9600 LUMENS, 4000K

COLOR TEMPERATURE, MIN 70 CRI LED UNV (120-277V) 90 CLEAR BLACK WALL SIGNIFY LYTEPRO LED

LPW32-90-NW-G3-UNV-PCB-BK

TYPE 3 DISTRIBUTION WITH

INTEGRAL PHOTOCELL

TYPE B

1'- 0"

EQ EQ

6"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

ELECTRICAL POWER ELEVATIONS -

ROOF 44

CONSTRUCTION

DOCUMENTS

AE DESIGN SERVICES FOR ROOF

REPLACEMENT

3495 BAILEY AVENUE

BUFALO, NY 14215

2019/11/13

EP201

B1

528-17-S49

SBV CJR

REV 0 - CONSTRUCTION DOCUMENTS 2019/11/13

"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".

A WING

E

WING

D WINGC WING

B WING

ROOF AREA 6 ROOF

AREA

ROOF

AREA 2

ROOF

AREA 1

ROOF

AREA

ROOF AREA 5

ROOF

AREA 4

KEYPLAN

ROOF

AREA 8

GENERAL NOTES

1. SEE E-001 FOR E-SERIES NOTES & LEGENDS.

SCALE: 1/2"=1'-0"

ELECTRICAL POWER ELEVATIONS - ROOF 441

EP101

DWG-18271-E-001.REV0 ELECTRICAL NOTES & LEGEND
Sheets and Views
DWG-18271-E-001.REVX ELECTRICAL NOTES & LEGEND
DWG-18271-ED101.REV0 ELECTRICAL DEMOLITION PLAN - ROOF AREA 1
Sheets and Views
DWG-18271-ED101.REVX ELECTRICAL DEMOLITION PLAN - ROOF AREA 1
DWG-18271-ED102.REV0 ELECTRICAL DEMOLITION PLAN - ROOF AREA 2
Sheets and Views
DWG-18271-ED102.REVX ELECTRICAL DEMOLITION PLAN - ROOF AREA 2
DWG-18271-ED104.REV0 ELECTRICAL DEMOLITION PLAN - ROOF AREA 4
Sheets and Views
DWG-18271-ED104.REVX ELECTRICAL DEMOLITION PLAN - ROOF AREA 4
DWG-18271-ED105.REV0 ELECTRICAL DEMOLITION PLAN - ROOF AREA 5
Sheets and Views
DWG-18271-ED105.REVX ELECTRICAL DEMOLITION PLAN - ROOF AREA 5
DWG-18271-ED106.REV0 ELECTRICAL DEMOLITION PLAN - ROOF AREA 6
Sheets and Views
DWG-18271-ED106.REVX ELECTRICAL DEMOLITION PLAN - ROOF AREA 6
DWG-18271-ED108.REV0 ELECTRICAL DEMOLITION PLAN - ROOF AREA 8
Sheets and Views
DWG-18271-ED108.REVX ELECTRICAL DEMOLITION PLAN - ROOF AREA 8
DWG-18271-ED401.REV0 ELECTRICAL DEMOLITION PLAN - ROOF 49
Sheets and Views
DWG-18271-ED401.REVX ELECTRICAL DEMOLITION PLAN - ROOF 49
DWG-18271-ED402.REV0 ELECTRICAL DEMOLITION PLAN - ROOF 44
Sheets and Views
DWG-18271-ED402.REVX ELECTRICAL DEMOLITION PLAN - ROOF 44
DWG-18271-EG101.REV0 ELEC LIGHTNING PROT PLAN - ROOF AREA 1
Sheets and Views
DWG-18271-EG101.REVX ELEC LIGHTNING PROT PLAN - ROOF AREA 1
DWG-18271-EG102.REV0 ELEC LIGHTNING PROT PLAN - ROOF AREA 2
Sheets and Views
DWG-18271-EG102.REVX ELEC LIGHTNING PROT PLAN - ROOF AREA 2
DWG-18271-EG104.REV0 ELEC LIGHTNING PROT PLAN - ROOF AREA 4
Sheets and Views
DWG-18271-EG104.REVX ELEC LIGHTNING PROT PLAN - ROOF AREA 4
DWG-18271-EG105.REV0 ELEC LIGHTNING PROT PLAN - ROOF AREA 5
Sheets and Views
DWG-18271-EG105.REVX ELEC LIGHTNING PROT PLAN - ROOF AREA 5
DWG-18271-EG106.REV0 ELEC LIGHTNING PROT PLAN - ROOF AREA 6
Sheets and Views
DWG-18271-EG106.REVX ELEC LIGHTNING PROT PLAN - ROOF AREA 6
DWG-18271-EG-501.REV0 ELECTRICAL LIGHTNING DETAILS
Sheets and Views
DWG-18271-EG-501.REVX ELECTRICAL LIGHTNING DETAILS
DWG-18271-EP101.REV0 ELECTRICAL POWER PLAN - ROOF 44
Sheets and Views
DWG-18271-EP101.REVX ELECTRICAL POWER PLAN - ROOF 44
DWG-18271-EP201.REV0 ELECTRICAL POWER ELEVATIONS - ROOF 44
Sheets and Views
DWG-18271-EP201.REVX ELECTRICAL POWER ELEVATIONS - ROOF 44

File details come from the government source that posted it. Updated .