S02 - Damen 1-A Panel Breaker Survey.xlsx

XLSX spreadsheet 36 KB Posted

Attached to
J059--Triennial Electical Panel Maintenance and Survey Federal contract opportunity
Solicitation number
36C25226Q0359
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

This is an electrical panel breaker survey document for Building 1-A (Damen) at a Department of Veterans Affairs facility, dated January 2, 2025. The survey comprehensively catalogs circuit breaker panels across ten floors, documenting panel locations, types (normal, emergency, or distribution), panel names, number of breakers, and associated deficiencies requiring remediation. The survey identifies specific deficiencies including unlabeled breakers that are energized, missing filler plates, and discrepancies between breaker status and labeling across multiple rooms and floors. Deficiencies are concentrated in panels designated as GK, GB, GV, GBA, GBB, GECM-2, DGV, EGV, and various numbered panels (CB panels), with the most significant issues noted in emergency and normal panels on the 1st, 3rd, 4th, and 5th floors.

The document appears to support the triennial electrical panel maintenance and survey solicitation (36C25226Q0359) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12. The survey results provide detailed baseline data for identifying required corrective actions, including breaker labeling, installation of filler plates, and verification of panel operation status. This survey documentation would be essential for contractors responding to the maintenance solicitation to understand the scope of work required across the facility's electrical infrastructure and to develop accurate proposals for bringing all panels into compliance with federal safety standards.

View the file

Other files for this federal contract opportunity

Other files attached to J059--Triennial Electical Panel Maintenance and Survey, newest first.
File Type Posted
S02 - Substations and Switchgears.xlsx XLSX spreadsheet
36C25226Q0359 0004.docx DOCX document
S02 - Taylor bldg.pdf PDF
S02 - One Line Diagram - No Bedtower.pdf PDF
S02 - Damen bldg.pdf PDF
S02 - Atrium.pdf PDF
36C25226Q0359 0003.docx DOCX document
S02 - Ogden bldg.pdf PDF
S02 - Bed Tower One Line Diagram.pdf PDF
S02 - Bed Tower bldg.pdf PDF
36C25226Q0359 0002.docx DOCX document
36C25226Q0359 0001.docx DOCX document
S02 - WD 2015-5017 R 32 D 3.30.26.pdf PDF
S02 - Taylor Panel Breaker Survey.xlsx XLSX spreadsheet
S02 - Building 21-26-27 Panel Breaker Survey.xlsx XLSX spreadsheet
S02 - Temp Building Panel Breaker Survey.xlsx XLSX spreadsheet
S02 - Building 42 Panel Breaker Survey.xlsx XLSX spreadsheet
36C25226Q0359.docx DOCX document
S02 - Electrical Units 3Y Maintenance Total number of brakers.xlsx XLSX spreadsheet
S02 - Damen 1-C Panel Breaker Survey.xlsx XLSX spreadsheet
S02 - -Atrium Panel Breaker Survey.xlsx XLSX spreadsheet
S02 - -Bed Tower Panel Breaker Survey r1.xlsx XLSX spreadsheet
S02 - Building Schedule.docx DOCX document
S02 - Ogden Panel Breaker Survey.xlsx XLSX spreadsheet
S02 - Damen 1-B Panel Breaker Survey.xlsx XLSX spreadsheet
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1st

BUILDING 1-A: Damen 1st Floor
1.2.25
ITEM#FLOORROOMPANEL TYPEPANEL NAME# E PanelsFED FROMDEFICIENCY
11st1508NormalGK11GKBreakers on and no labeled: #30
21stPolk DockNormalGK1SS2/CB#14Breakers on and no labeled: #7,9,(8,10),12,14
31st15E2NormalGB1SS2/CB12Breakers on and no labeled: #6,34,36,38
41st15E4EmergencyEGBEDGVNone
51st15E4NormalCV1 SEC1CDGVNeeds (5) fillers
61st15E4NormalCV1 SEC2CDGVNeeds (1) filler
71st15E4NormalGL1SS2 1573 F6BNone
81st15E4NormalGV21SS2 1573 DGVBreakers on and no labeled: #14,16, 18, 19,20,22
91st1555NormalNo NameGECM-2None
101st1555NormalGBBDGVNone
111st1576NormalGBADGVNone
121st15E3Distribution EmergencyEDGVSS2-CB19None
131st15E3NormalGV11SS2-CB29Breakers on and no labeled: #2,4,6,8,10,12
141st15E3EmergencyEGV1EDGVBreakers on and no labeled: #25,27,29,31,33,30,34,36,38
151st15E3EmergencySPS TRAILER1EDGVBreakers on and no labeled: #12
161st15E3NormalDGVSS2-CB29None
7

2nd & 3rd

BUILDING 1-A: Damen 2nd & 3rd Floor
1.2.25
ITEM#FLOORROOMPANEL TYPEPANEL NAME# E PanelsFED FROMDEFICIENCY
12nd25E2Normal1BLD1BNone
22nd25E1Normal1BRSS-2 CBF-12-DNone
32ndNext to 25E1EmergencyC1B1CDGVBreakers on and no labeled: #3,6
42nd25E3Normal1L1L1None
52nd25E2NormalD1B51SS2 CB21-D1BBreakers on and no labeled: #7,9,20,24
62nd25E2Distribution NormalDIBSS2 CB21None
73rd3560ANormalCB411SS2Breakers on and no labeled: #1,3,5,29,24
83rd3560ANormalCB421SS2Breakers on and no labeled: #(21,23), 25,(16,18) Needs (1) Filler
93rd3547Normal2L11SS2 - CB#6Breakers on and no labeled: #12,19,21
103rdNext to Stair #3EmergencyC2B1CDGVBreakers on and no labeled: #5,9,11,15,17,23,25,31,33,35,37 39 41,8,10,16,18,20,24,26,28,32,34,36,38,40,42
113rd35E1Normal2BR1SS2 - CBF-12-DBreakers on and no labeled: #10
123rd35E1NormalD1B31D1BBreakers on and no labeled: #12
8

4th

BUILDING 1-A: Damen 4th Floor
1.2.25
ITEM#FLOORROOMPANEL TYPEPANEL NAME# E PanelsFED FROMDEFICIENCY
14th45E2NormalD3B11D3BBreaker on and not labeled: #16
24th45E2EmergencyE3B1EDGV 13-15-17Breaker on and not labeled: #4,16
34th45E2NormalH3B1HDGV72None
44th45E2NormalB3051SS2/CB44Breakers on and not labeled: #33 Breakers off and labeled:#21,18,40
54th45E2NormalC3L21C3LBreakers off and labels: #40,42 Breakers off and labeled:#5,2,4,6,26,28,30
64th45E2Distribution NormalD3BSS2 CB22None
74thHallway Next Rm #4588NormalD3B41D3BBreakers off and labeled: #1,3,11,13,12,14,16,20,30 Needs (4) fillers
84th4549 LABNormalD3B3D3BConstruction Area
94th4549 LABNormalD3B5D3BConstruction Area
104th4549 LABEmergencyC3L1SS2 CB20Breakers off and labeled:#35,37,39,34,36 Breakers on and not labeled: #(21,23),32
114th4549 LABNormalEPP1CLP - 4 - 1Breakers on and not labeled: #22,24,26
124th4544NormalD3B6D3BConstruction Area
134thNo RM # In Construction AreaNormal3DNSS2 CB30None
144thNo RM # In Construction AreaNormalC3DCDGVNone
154th45E1Normal3BR1SS2 - F-12-BBreakers on and not labeled: #29
164thNext to Rm 45E1EmergencyC3B1CDGVBreakers on and not labeled: #17,19,21,23,31,33,37,39,41,16 18,20,22,24,32,34,36,38
9

5th & 6th

BUILDING 1-A: Damen 5th & 6th Floor
1.2.25
ITEM#FLOORROOMPANEL TYPEPANEL NAME# PANELSFED FROMDEFICIENCY
15th55E2NormalC5B21CD5Breakers on and not labeled: #(32,34),(36,38),(40,42)
25th55E2NormalRP-5-21MCC-5LBreakers on and not labeled: #17,30
35th55E1Normal4BSS-2 F-12-BNone
45th55E3NormalCD51SS2 - F5BBreakers on and not labeled: #(10,12),(1,3,5),(7,9,11)
55th55E3EmergencyLSUnknownNone
65th55E3NormalRP-5-1MCC-5LNone
75th55E3NormalLP-5-11MCC-5LBreaker on and not labeled: #17
85th55E3NormalC5B11CD5Breakers on and not labeled: #35,37
96th65E1Normal5B1SS-2 F-12-BBreakers on and not labeled: #20,22,41,42
106th65E1EmergencyE5B1EDGVBreaker off and labeled: #17 Breaker on and not labeled: #19
116thNext to Rm 65E1EmergencyC5B1CDGVBreaker on and not labeled: #17
126thNext to Rm 65E1Normal5BNSS2 - CB#5None
8

7th & 8th

BUILDING 1-A: Damen 7th & 8th Floor
1.2.25
ITEM#FLOORROOMPANEL TYPEPANEL NAME# PANELSFED FROMDEFICIENCY
17thAcross From Rm 7554Normal6B2UnknownNone
27thAcross From Rm 7554Normal6BSS-2 F-12-ANone
37thAcross From Rm 7554EmergencyC6B1CDGVBreaker on and not labeled: #17
47thAcross From Rm 7554Normal6BNSS2 CB5None
58th8551Normal7BSS-2 F-12-ANone
68thNext to Rm 8551NormalC7BCDGVNone
78thNext to Rm 8551Normal7BNSS2 CB5None
1

9th & 10th

BUILDING 1-A: Damen 9th & 10th Floor
# PANELS1.2.25
ITEM#FLOORROOMPANEL TYPEPANEL NAMEFED FROMDEFICIENCY
19th95E1Normal8BSS-2 F-12-ANone
29thNext to 95E1EmergencyC8BCDGVNone
39thNext to 95E1Normal8BNSS2 CB5None
410th10520Normal9B1SS-2 F-12-ABreakers on and not labeled: #26,28
1

File details come from the government source that posted it. Updated .