S02 695-21-110 Drawings Part 3.pdf
PDF 4 MB Posted
- Solicitation number
- 36C25223B0030
About this file
This solicitation is for repair work on the North Campus Steam Tunnel at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The required work includes repairs and replacement of existing infrastructure in six segments of the steam tunnel, including replacement of lighting fixtures, electrical conduits, junction boxes, and other system components. The solicitation number is 36C25223B0030 and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12. The contractor shall complete all work by January 15, 2024. The solicitation includes plans, specifications, and details for civil, structural, architectural, and electrical scope.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01.31-24
01.31-25
01.31-26
02.01-2
02.01-5
02.01-7
02.01-8
02.01-9
02.01-12
02.01-18
02.01-25
02.01-22
02.01-28
02.01-26
02.01-30
02.01-31
02.01-32
02.01-33
02.01-35
02.01-37
02.01-38
02.01-39
02.01-44
02.01-45
02.01-42
02.01-43
13 1
14 4
2 1
14 2
4 1
4 9
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:1
P
M C
U s e rs \m la il\
D o c u m e n ts
\A
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ m la ilC
F J
.r v t
A-101
EXISTING CONDITIONS 2
2 4RF
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
CLA
DocuSign Envelope ID: BF3A282E-37F9-4F35-ABBD-8CF3F5B9B0F8
7/13/2023
EXISTING PIPE
SUPPORT FRAME,
COORD. W/ STRUCT.
EXISTING PIPE
SUPPORT FRAME,
COORD. W/ STRUCT.
EXISTING CONCRETE
TUNNEL
EXISTING LIGHT
FIXTURE TO BE
REMOVED, SEE ELEC.
VIF
6'-0"
EXISTING
CHAMFERED EDGE
EXISTING
CHAMFERED EDGE
EXISTING
CHAMFERED EDGE
EXISTING INSULATED
STEAM PIPES
EXISTING CONDUIT.
E.T.R. UNLESS
OTHERWISE NOTED,
REFER TO
ELECTRICAL
V
IF
EXISTING PIPE
SUPPORT BASE,
COORD. W/ STRUCT.
EXISTING
CHAMFERED EDGE
EXISTING 4'' DRAIN
PIPE
EXAUST COVER
AND FAN, SEE
CIVIL
SEALED MANHOLE,
SEE CIVIL
EXISTING
CONCRETE RISER
EXISTING
PRECAST TUNNEL
EXISTING VENTILATION
SHAFT V-2
EXISTING
MANHOLE M-1
VAULT C
EXISTING STEEL
RUNGS
EXISTING MOVEABLE
PLATE
EXISTING RAIL NOT
SHOWN FOR CLARITY
VIF
21'-3"
V
IF
NEW LADDER AND
LANDING, SEE
A-300
V
IF
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
CONTINUOUS SEALANT
AT EDGE (TYP)
CONTINUOUS
SEALANT AT EDGE
(TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT SYSTEM
(TYP)
2'-0" 2'-0"
LIGHTWEIGHT CONCRETE
1/8" PER FOOT SLOPE TO
SHED WATER
A-300
EXISTING TUNNEL TO
BUILDING 5 BEYOND
EXISTING PRECAST
TUNNEL
EXISTNG SERVICE
CHASE S-3
VAULT D
CONTINUOUS
SEALANT AT EDGE
(TYP)
4'-0"
4'-8"
VIF
14'-2"
V
IF
NEW LADDER AND
LANDING, SEE
A-300
CONTINUOUS
SEALANT AT EDGE
(TYP)
VENTILATION HOOD,
SEE CIVIL
V
IF
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
SYSTEM (TYP)
2'-0"
2'-0"
LIGHTWEIGHT CONCRETE
1/8" PER FOOT SLOPE TO
SHED WATER
A-300
JOINT FILLER AND
JOINT SEALANT
(TYP)
EXISTING
PRECAST TUNNEL
VENTILATION HOOD,
SEE CIVIL
EXISTING
GRATING
EXISTING STEEL
BEAM
EXISTING VENTILATION
SHAFT V-1.
VAULT B
DEMOLISH AND REMOVE (2) EXISTING
HURLING CHAMBERS. CONFIRM THEY
ARE NOT CONNECTED TO
ELECTRICAL, PLUMBING, OR
MECHANICAL BEFORE DEMOLITION
PRIMER (TYP)
VIF
15'-10"
V
IF
WATERPROOFING
MEMBRANE (TYP)
V
IF
WATER PROOFING SYSTEM
ADHERED TO EXISTING
CONCRETE
2'-0"
V
IF
LIQUID WATERPROOFING
MEMBRANE AT JOINTS
(TYP)
DRAINAGE MAT SYSTEM
(TYP)
CONTINUOUS SEALANT
AT EDGE (TYP)
LIGHTWEIGHT CONCRETE
1/8" PER FOOT SLOPE TO
SHED WATER
CONTINUOUS SEALANT
AT EDGE (TYP)
2'-0"
EXISTING CONCRETE
TUNNEL
LIGHT FIXTURE, COORD.
W/ ELECTRICAL
EXISITNG
CHAMFERED EDGE
EXISTING ARRAY OF
CONDUIT. E.T.R.
UNLESS OTHERWISE
NOTED, REFER TO
ELECTRICAL
EXISTING SERVICE
CHASE
SEALED MANHOLE,
SEE CIVIL
VIF
6'-0"
V
IF
JOINT FILLER AND JOINT
SEALANT
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
SYSTEM (TYP)
CONTINUOUS
SEALANT AT EDGE
(TYP)
CONTINUOUS
SEALANT AT EDGE
(TYP)
2'-0"
EXISTING CONCRETE
TUNNEL
LIGHT FIXTURE, COORD.
W/ ELECTRICAL
EXISTING
CHAMFERED EDGE
EXISTING VENTILATION
SHAFT V-3
EXAUST COVER AND
FAN, SEE CIVIL
VIF
6'-0"
V
IF
CONTINUOUS
SEALANT AT EDGE
(TYP)
CONTINUOUS
SEALANT AT EDGE
(TYP)
EXISTING ARRAY OF
CONDUIT. E.T.R.
UNLESS OTHERWISE
NOTED, REFER TO
ELECTRICAL
JOINT FILLER AND JOINT
SEALANT (TYP)
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
SYSTEM (TYP)
2'-0"
EXISTING MANHOLE,
SEE CIVIL
REMOVE EXISTING
WATERPROOFING
MEMBRANE (TYP)
REMOVE EXISTING
ADHESIVE (TYP)
REMOVE BURRS AND
IRREGUALR FEATUES.
PREP SURFACE FOR NEW
WATERPROOFING
SYSTEM (TYP)
REMOVE EXISTING
JOINT SEALANT AND
JOINT FILLER (TYP)
EXCAVATE AROUND
VERTICAL SHAFTS AND
VAULTS, SEE CIVIL
REMOVE EXISTING
WATERPROOFING
MEMBRANE (TYP)
REMOVE EXISTING
ADHESIVE (TYP)
SHAFT
VAULT
TUNNEL
MANHOLE, SEE CIVIL
ROUGHEN SURFACE TO
1/4" AMPLITUDE AND
APPLY EPOXY BONDING
AGENT
LIGHTWEIGHT CONCRETE
1/8" PER FOOT SLOPE TO
SHED WATER
2'' PROTECTION
BOARD
CONNECT DRAINAGE
MAT SYSTEM TO
EXISTING 4'' DRAIN
PIPE, SEE CIVIL
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
SYSTEM (TYP)
DRAINAGE MAT SYSTEM
(TYP)
RISER
VAULT
TUNNEL
EXISTING CONCRETE
VAULT
WATERPROOFING
MEMBRANE (TYP)
PRIMER (TYP)
EXISTING CONCRETE
VAULT
JOINT FILLER AND
JOINT SEALANT
(TYP)
2'-0"
CONTINUOUS SEALANT AT
EDGE (TYP)
EXCAVATE AROUND
VERTICAL RISER, SEE
CIVIL
EXISTING TUNNEL
EXISTING VERTICAL
RISER
DRAINAGE MAT
SYSTEM WRAPPED
AROUND THE RISER
(18"- 24" RADIUS)
ANCHOR PIPE
EXTENSION TO
RISER
NEW PIPE
CONNECTION TO
AN EXISTING
DRAIN PIPE
EXISTING 4" DRAIN
PIPE
MANHOLE, SEE CIVIL
LIQUID
WATERPROOFING
MEMBRANE AT JOINTS
(TYP)
SEE 1/A-200 FOR
DEMOLITION NOTES
FOR VERTICAL RISER
TUNNEL
RISER
WATERPROOFING
MEMBRANE (TYP)
PRIMER (TYP)
EXISTING CONCRETE
VAULT
JOINT FILLER AND
JOINT SEALANT
(TYP)
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:2
P
M C
U s e rs \m la il\
D o c u m e n ts
\A
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ m la ilC
F J
.r v t
A-200
STEAM TUNNEL AND VAULT SECTIONS
3 4LBB
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
CLA
Scale: 3/4" = 1'-0"
TYPICAL EXISTING TUNNEL SECTION
Scale: 1/4" = 1'-0"
VAULT C SECTION
Scale: 1/4" = 1'-0"
VAULT D SECTION
Scale: 1/4" = 1'-0"
VAULT B SECTION
Scale: 1/4" = 1'-0"
SERVICE CHASE S1 AND S2
Scale: 1/4" = 1'-0"
VENT SHAFT V3
1. ALL EXISTING ELEMENTS ARE EXISTING TO
REMAIN UNLESS NOTED OTHERWISE.
2. CONTRACTOR TO PATCH AND REPAIR ANY
DAMAGE TO THE EXISTING CONCRETE THAT
OCCURS DURING THE PROJECT.
3. THOROUGHLY CLEAN OUT THE EXISTING JOINTS
PRIOR TO INSTALLING NEW JOINT FILLER AND
SEALANT. SEE DETAIL 4/A-300.
Scale: 1/4" = 1'-0"
TYPICAL VERTICAL SHAFTS
AND VAULT DEMOLITION DIAGRAM
1. REMOVE EXISTING WATERPROOF MEMBRANE
AND ADHESIVE, PROVIDE A SMOOTH CLEAN
SURFACE FOR INSTALLATION OF NEW
WATERPROOFING MATERIALS.
2. REMOVE AN BURRS AND ABNORMALITIES FROM
PRECAST CONCRETE SURFACE TO ELIMINATE
POTENTIAL PUNCTURS TO NEW
WATERPROOFING SYSTEM.
3. POWERWASH TO REMOVE BLEMISHES ON
PRECAST CONCRETE.
4. APPLY PRIMER BEFORE THE WATERPROOFING
IS APPLIED.
DEMO NOTES:
SHEET NOTES:
Scale: 1/4" = 1'-0"
TYPICAL VERTICAL SHAFTS
AND VAULT DIAGRAM
Scale: 1/4" = 1'-0"
TYPICAL VERTICAL RISER DIAGRAM
NOTES:
1. CLEAN ALL RESIDUE AND DAMAGED SURFACES
EXISTING CONC. JOINT
OUTSIDE OF
RISER
INSIDE OF
RISER
POLYURETHENE ELASTOMERIC
SEALANT
2'' WIDE LIQUID
MEMBRANE (TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
(TYP)
MANHOLE COVER,
SEE CIVIL
EXISTING STEEL
RUNGS ETR
A-300
EXISTING CONC.
SHAFT
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
(TYP)
CONTINUOUS SEALANT
AT EDGE (TYP)
2'-0" 2'-0"
POLYURETHENE
ELASTOMERIC
SEALANT & JOINT
FILLER (TYP)
EXISTING CONC CAP @ TUNNEL
C
O
N
D
U
I
T
POLYURETHENE
ELASTOMERIC SEALANT
EXISTING JOINT
FILLER & JOINT SEALANTOUTSIDE TUNNEL
INSIDE TUNNEL
EXISTING CONC WALL
COMPOSITE BOTTOM
DUCT DRAIN
COLLECTOR SYSTEM,
COORD. W/ CIVIL
OUTSIDE OF
VAULT
INSIDE OF
VAULT
POLYURETHENE
ELASTOMERIC
SEALANT
EXISTING CONC. JOINT
PROTECTION BD 2''
RIGID FOAM
PRIMER (TYP)
WATERPROOFING
MEMBRANE (TYP)
DRAINAGE MAT
(TYP)
2'' WIDE LIQUID
MEMBRANE (TYP)
4" DRAINAGE PIPE
DRAINAGE MAT SYSTEM (TYP)
ADHERED (60 MIL)
WP MEMBRANE
INSTALL CORNER AND
CANT DETAILS PER MFR'S
RECOMMENDATIONS
DRAINAGE MAT
ADHERED (60 MIL)
WP MEMBRANE
POLYURETHENE
ELASTOMERIC
SEALANT
8"
/2
OUTSIDE OF
VAULT
INSIDE OF
VAULT
POLYURETHENE
ELASTOMERIC
SEALANT
LIQUID
WATERPROOFING
MEMBRANE AT
JOINTS (TYP)
2'' WIDE LIQUID
MEMBRANE (TYP)
POLYURETHENE
ELASTOMERIC
SEALANT
LIGHTWEIGHT
CONCRETE
2'-1"
1'-10"
ELEVATION PLAN
5 RUNGS @ 1' O.C.
/8
2'-1 3/4"
ELEVATION PLAN
25 RUNGS @ 2 3/4" O.C.
2'-1 3/4"
2'-1 3/4"
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:2
:1
P
M C
U s e rs \l b y rd
\D o c u m e n ts
\A
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ lb y rd
V D
E K
F .r v t
A-300
REPAIR DETAILS
4 4LBB
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
CLA
Scale: 3" = 1'-0"
JOINT SEALANT DETAIL
Scale: 1/2" = 1'-0"
VERTICAL RISER
Scale: 3" = 1'-0"
CONDUIT SEALANT DETAIL
Scale: 3" = 1'-0"
COMPOSITE DRAINAGE DETAIL
Scale: 3" = 1'-0"
VERTICAL RISER TO VAULT TIE IN
Scale: 1/2" = 1'-0"
VAULT D LADDER
Scale: 1/2" = 1'-0"
VAULT C LADDER
L L
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TC TIMECLOCK
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TTB TELEPHONE TERMINAL BOARD
TTC TELEPHONE TERMINAL CABINET
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
UT UNDERGROUND TELEPHONE
UTP UNSHIELDED TWISTED PAIR
UTIL UTILITY
UV UNIT VENTILATOR OR
ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
ANGLE
@ AT
DELTA
' FEET
" INCHES
# NUMBER
Φ PHASE
C CENTER LINE
P PLATE
MTR MOTOR, MOTORIZED
MTS MANUAL TRANSFER SWITCH
NA NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT
SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OL OVERLOAD
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PBPU PREFABRICATED BEDSIDE PATIENT
UNIT
PCB POLYCHLORINATED BIPHENYL
PC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
POE POWER-OVER-ETHERNET
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QTY QUANTITY
R RELOCATE/RELOCATED
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
REQD REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SF SQUARE FEET/FOOT
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
1P 1 POLE (2P, 3P, 4P, ETC.)
1PH 1 PHASE
2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)
2W TWO-WIRE (3W, 4W, ETC.)
3PH 3 PHASE
A AMPERE
AAP ALARM ANNUNCIATOR PANEL
AC ABOVE COUNTER
AIR CONDITIONER
ALTERNATING CURRENT
ACC ACCESSIBLE
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
A/E ARCHITECT/ENGINEER
AF AMP FRAME
AFC AVAILABLE FAULT CURRENT (KILOAMPS)
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT INTERRUPTER
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CAPACITY
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
APPROX APPROXIMATELY
ARCH ARCHITECT, ARCHITECTURAL
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BATT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISHED FLOOR
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
BYP BYPASS
C CONDUIT
CAB CABINET
CALC CALCULATED
CAP CAPACITY
CAT CATALOG, CATEGORY
CATV COMMUNITY ANTENNA TELEVISION
CB CIRCUIT BREAKER
CCR CONTROL CONTACTOR
CCT CORRELATED COLOR TEMPERATURE
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR-FURNISHED
CKT CIRCUIT
CLG CEILING
CO CONTRACTING OFFICER
COAX COAXIAL CABLE
COMM COMMUNICATION
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CTR CENTER
CU COPPER
CU FT CUBIC FEET
D DEMOLITION
dB DECIBEL
DB DIRECT BURIAL
DC DIRECT CURRENT
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLISH/DEMOLITION
DEPT DEPARTMENT
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EG EQUIPMENT GROUND
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EPO EMERGENCY POWER OFF
EQUIP EQUIPMENT
ESMT EASEMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WALL HEATER
ELECTRIC WATER HEATER
EX EXISTING
EXP EXPLOSION PROOF
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FU FUSE
FUDS FUSED SAFETY DISCONNECT
SWITCH
FVR FULL VOLTAGE REVERSING
FVNR FULL VOLTAGE NON-REVERSING
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HID HIGH-INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IES ILLUMINATION ENGINEERING SOCIETY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IR INFRARED
I/W INTERLOCK WITH
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LED LIGHT-EMITTING DIODE
LF LINEAR FEET/FOOT
LM LUMEN
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
METAL-CLAD (CONDUIT)
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT SWITCH
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MOA MULTIOUTLET ASSEMBLY
MSBD MAIN SWITCHBOARD
MT MOUNT
A1 b
E1 c d
T1
'LPN'
THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER
CASE LETTER AND NUMBER.
THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.
EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.
EXIT SIGNS: STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING
MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES
DIRECTIONAL ARROW ON ILLUMINATED FACE(S).
DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER
FOLLOWING THE UPPER CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR
THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER DESCRIPTION AND
REQUIREMENTS.
PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING
SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR
DESIGNATION CODES.
SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE
NUMBER INDICATED IN THE HEXAGON.
HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT
DESIGNATION ARE SHOWN ADJACENT TO THE HOME RUN ARROW.
CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL
SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.
SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE
A UNIT TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.
'LPN'-1,3,5
EXAMPLE 1: WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE
AND DIRECTIONAL ARROW.
EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE
FACE AND DIRECTIONAL ARROWS.
E2
EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS
CONTROLLED BY SWITCH 'c'.
EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING FIXTURES INDICATED BY 'd'.
EXAMPLE: TRANSFORMER TYPE 'T1'.
EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.
# DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE
NOTE NUMBER INDICATED IN THE SQUARE.
1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VA
STANDARDS.
2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE BUILDING
CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.
3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.
4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED MOUNTING HARDWARE TO
SUIT THE PARTICULAR INSTALLATION.
5. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.
6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.
7. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID CONFLICT DURING
CONSTRUCTION.
8. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR SPACE.
9. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST COMPLY WITH "BUY AMERICAN ACT".
10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR EQUIPMENT
MANUFACTURER'S SPECIFICATIONS.
11. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE DEVICE'S SCREW
TERMINALS.
12. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT UNLESS NOTED
OTHERWISE.
13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.
14. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.
15. ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND CONDUIT OR WHERE CONCRETE- ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE, LFMC CONDUIT SHALL BE USED (MAXIMUM SIX FEET) FOR
FINAL CONNECTIONS.
16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD
PARTY TESTING AGENCY.
17. FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS.
PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.
PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.
18. IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS DETERMINED BY THE GOVERNMENT, SHALL BE
PROVIDED.
19. COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.
20. MINIMUM CONDUIT SIZE TO BE USED IS 3/4".
21. FEEDER TAGS APPENDED WITH 'VD' ARE UPSIZED IN AMPACITY DUE TO VOLTAGE DROP.
22. DOWNTIME RESULTING FROM THE REWORKING AND SPLICING OF THE FIRE ALARM LOOP SHALL BE COORDINATED WITH
THE COR.
23. SOME COMPONENTS OF EXISTING SYSTEMS MAY HAVE CODE VIOLATIONS BEFORE AND DURING DEMOLITION, PARTICULARLY ABOVE CEILINGS, BEHIND CHASE WALLS, IN-WALL, AND ABOVE AND BELOW PRIMARY SPACES TO BE DEMOLISHED WHEN NOT DOCUMENTED ON DRAWINGS, AND NOT OBSERVED DURING SITE WALK-THROUGH.
24. RE-SUPPORT EXISTING SYSTEM COMPONENTS NOT PROPERLY SUPPORTED AFTER DEMOLITION AND NOT SCHEDULED
FOR WORK.
120V DUPLEX RECEPTACLE
RECEPTACLE MODIFIERS:
AC: 3" ABOVE COUNTERTOP/BACKSPLASH
GFI: GROUND FAULT CURRENT INTERRUPTER
WP: WEATHERPROOF ENCLOSURE
DED: DEDICATED CIRCUIT
120V DUPLEX RECEPTACLE EMERGENCY OUTLET
AND COVER PLATE SHALL BE RED IN COLOR
120V QUADRUPLEX RECEPTACLE
120V QUADRUPLEX RECEPTACLE EMERGENCY
OUTLET AND COVER PLATE SHALL BE RED IN COLOR
JUNCTION BOX, WALL MOUNTED, PURPOSE AS NOTED
DISCONNECT SWITCH NON-FUSED
DISCONNECT SWITCH FUSED
SINGLE POLE WALL SWITCH: 48" AFF STANDARD UNO
3: 3-WAY SWITCH
SYMBOL HEIGHT DESCRIPTION
18"
18"
18"
18"
AS
NOTED
72" TOP
72" TOP
SWITCH MODIFIERS:
M: MOTOR-RATED
48"
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO TOP OF DEVICE
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERSEDE THOSE LISTED HERE.
SPECIAL RECEPTACLE
EQUIPMENT CONNECTION
AS
NOTED
E
208V DUPLEX RECEPTACLE18"
18"
120V DUPLEX RECEPTACLE FLOOR BOX
120V DUPLEX RECEPTACLE EMERGENCY FLOOR BOX
OUTLET AND COVER PLATE SHALL BE RED IN COLOR
120V QUADRUPLEX RECEPTACLE FLOOR BOX
120V QUADUPLEX RECEPTACLE EMERGENCY
FLOOR BOX OUTLET AND COVER PLATE SHALL BE
RED IN COLOR
CLNG
J
J
J
JUNCTION BOX, CEILING MOUNTED, PURPOSE AS
NOTED
JUNCTION BOX, FLOOR MOUNTED, PURPOSE AS
NOTED
120V SIMPLEX RECEPTACLE18"2' X 2' RECESSED ARCHITECTURAL TROFFER
2' X 4' RECESSED ARCHITECTURAL TROFFER
SYMBOL
HEIGHT
AFF * DESCRIPTION
--- 2' X 4' RECESSED FLAT LENS TROFFER
2' LINEAR - WALL MOUNTED
7'-0"
CENTER
4' LINEAR - WALL MOUNTED
7'-0"
CENTER
WALL SCONCE
6'-0"
CENTER
6" DIAMETER RECESSED DOWNLIGHT---
EXIT SIGN - WALL MOUNTED
EXIT SIGN - CEILING MOUNTED---
7'-5"
BOTTOM
SINGLE POLE WALL SWITCH
SWITCH MODIFIERS:
OS: OCCUPANCY SENSOR, LOW VOLTAGE,
DUAL TECHNOLOGY
VS: VACANCY SENSOR, LOW VOLTAGE,
DUAL TECHNOLOGY
DR: DUAL RELAY
VSD: VACANCY SENSOR, LINE VOLTAGE, DIMMER
OSD: OCCUPANCY SENSOR, LINE VOLTAGE, DIMMER
LV: LOW VOLTAGE
LVD: LOW VOLTAGE DIMMER
D: LINE VOLTAGE DIMMER
T: DIGITAL TIMER
K: KEYED
3: 3 WAY
4: 4 WAY
48"
CENTER
OCCUPANCY SENSOR, LOW VOLTAGE,
DUAL TECHNOLOGY - CEILING MOUNTED
--- LOW VOLTAGE LIGHTING CONTROL DEVICE
OCCUPANCY SENSOR, LOW VOLTAGE, DUAL
TECHNOLOGY - WALL/CORNER MOUNTED
EMERGENCY LIGHT BATTERY
OPERATED - WALL MOUNTED
7'-6"
CENTER
RC
* - ANY HEIGHTS INDICATED IN PLANS SHALL SUPERSEDE THOSE LISTED HERE.
LIGHT LEVEL SENSOR, SINGLE ZONE
DIMMING CLOSED LOOP - CEILING MOUNTED
--- LOW VOLTAGE LIGHTING CONTROL
DEVICE WITH 0-10V DIMMING
RCD
OS
OS
LS
4' LINEAR STRIP - SUSPENDED---
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
E-001
ELECTRICAL GENERAL NOTES,
SYMBOL LEGENDS, AND
ABBREVIATIONS
1 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
ELECTRICAL ABBREVIATIONS LIST
ELECTRICAL SYMBOL NOTES
ELECTRICAL GENERAL NOTES
ELECTRICAL SYMBOL LEGENDLIGHTING SYMBOL LEGEND
DocuSign Envelope ID: 691F5C9B-B47B-4F99-8EB6-F65BAB2DAB16
7/13/2023 7/13/2023
ET-101
ET-102
ET-103
ET-104
ET-105
ET-106
SERVICE
CHASE S-1
SERVICE
CHASE S-2
SERVICE
CHASE S-3
VENT SHAFT V-2
MANHOLE M-1
SPUR
TUNNEL
VENT
SHAFT V-1
VENT SHAFT
V-3
TO BOILER PLANT VAULT B
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
VAULT D
VAULT C
SPUR TUNNEL
TO BUILDING 5
TUNNEL NOT IN SCOPE
LEGEND
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-100
ELECTRICAL SITE PLAN
2 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
Scale: 1" = 30'-0"
ELECTRICAL SITE PLAN
NORTH
0 3015 60
GFIW
P
GFIW
P
EXISTING
PANEL
'EPH-Q-VLTB-1'
EXISTING
PANEL
'EPL-Q-VLTB-1'
EXISTING XFMR
'EPH-Q-VLTB-1'
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'
- 13
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'
- 13
VAULT B
SPUR
TUNNEL
VENT
SHAFT V-1
MATCH LINE ET-102
MATCH LINE ET-101
EM
BUILDING
EM
EM
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-101
ENLARGED SITE PLAN - SEGMENT 1
3 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NORTH
0 4 8 16
1 REPLACE EXISTING LIGHTING FIXTURES
WITH NEW. RETAIN EXISTING CIRCUIT FOR
NEW INSTALLATION. SEE DETAILS 1 AND 3 ON
E-501 FOR MORE INFORMATION.
2 PROVIDE NEW GFI, WEATHER PROOF
RECEPTACLE FED FROM SPARE CIRCUIT IN
PANEL ‘EPL-Q-VLTB-1’. SEE PANEL SCHEDULE
ON E-501 FOR MORE INFORMATION.
3 EXISTING 2-INCH CONDUIT WITH 24 STRAND
FIBER TO REMAIN.
4 REPLACE 10’ OF 3/4” EMT CONDUIT. PROVIDE
2 J-BOXES FOR SPLICE CONNECTIONS.
REFER TO IMAGE ET-101-01 ON SHEET ET-101
FOR MORE INFORMATION.
5 EXISTING FIBER OPTIC CABLE IN INNERDUCT
AT CEILING TO REMAIN.
6 EXISTING FIRE ALARM PULL BOX WITH FIBER
TO REMAIN.
7 EXISTING PULL BOX WITH FIBER TO REMAIN.
8 EXISTING 1/2” CONDUIT TO LIGHTS TO BE
REMOVED ALONG NORTH SIDE OF SPUR
TUNNEL. INSTALL NEW LIGHTS AND
RECEPTACLES AS SHOWN. SEE DETAIL 2 ON
SHEET E-501 FOR MORE INFORMATION.
9 REMOVE EXISTING CONDUIT AND WIRING.
SEAL PENETRATION THROUGH TUNNEL
ROOF. REFER TO IMAGE ET-101-02 ON SHEET
ET-101 AND ARCHITECTURAL SHEETS FOR
MORE INFORMATION.
10 REPLACE 5’ OF CONDUIT GOING INTO VENT
SHAFT ALONG WITH J-BOXES. REFER TO
IMAGE ET-101-03 ON SHEET ET-101 FOR
MORE INFORMATION.
11 PROVIDE NEW LIGHTING FIXTURES. FED
FROM CIRCUIT AS SHOWN.
A. REFER TO DETAIL 2 ON SHEET E-501 FOR
TYPICAL ELEVATIONS FROM VAULT B TO
BLDG 43.
B. REFER TO DETAIL 3 ON SHEET E-501 FOR
TYPICAL ELEVATIONS FROM VAULT B TO
VAULT C.
C. ALL EM FIXTURES ARE FED FROM EXISTING
PANEL '7X' CIRCUIT 10.
D. REPLACE LIGHT FIXTURES ONE CIRCUIT AT
A TIME TO KEEP AS MANY LIGHTS ON AS
POSSIBLE DURING CONSTRUCTION.
E. REPLACE EXISTING CIRCUIT NUMBERS ON
WIRES IN J-BOXES WITH CORRECT CIRCUIT
NUMBERS.
F. CONTRACTOR TO SEAL AROUND CONDUIT
PENETRATION THROUGH TUNNEL
WALL/CEILING.
G. CLEAR OFF DEPOSITS ON EXISTING
CONDUIT.
Scale: 1/8" = 1'-0"
ENLARGED SITE PLAN - SEGMENT 1
ET-101-01
ET-101-02
ET-101-03
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
GFI
WP
SERVICE
CHASE S-1
'EPL-Q-VLTB-1'-
EM
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
EM
MATCH LINE ET-102
MATCH LINE ET-101
MATCH LINE ET-103
MATCH LINE ET-102
TUNNEL NOT IN SCOPE
LEGEND
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-102
ENLARGED SITE PLAN - SEGMENT 2
4 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NORTH
0 4 8 16
1 REPLACE EXISTING LIGHTING FIXTURES
WITH NEW. RETAIN EXISTING CIRCUIT FOR
NEW INSTALLATION. SEE DETAILS 1 AND 3 ON
E-501 FOR MORE INFORMATION.
2 SWITCHES AND GFI RECEPTACLE ARE
EXISTING TO REMAIN.
3 REPLACE 10’ OF 1” EMT CONDUIT AND
CONTROL CABLING FOR JOHNSON
CONTROLS. PROVIDE 2 J-BOXES FOR SPLICE
CONNECTIONS. REFER TO IMAGE ET-102-01
ON SHEET ET-102 AND DETAIL 3 ON SHEET
E-501 FOR MORE INFORMATION.
4 REPLACE 7’ OF 1” EMT CONDUIT AND
CONTROL CABLING FOR JOHNSON
CONTROLS TO PULL BOX. SEE DETAIL 3 ON
E-501 AND IMAGE ET-102-02 FOR MORE
INFORMATION.
5 EXISTING JOHNSON CONTROLS PULL BOX TO
REMAIN. SEE IMAGE ET-102-03 FOR MORE
INFORMATION.
6 EXISTING FIRE ALARM PULL BOX WITH
CONTACTS FOR MECHANICAL EQUIPMENT TO
REMAIN.
A. REFER TO DETAIL 3 ON E-501 FOR TYPICAL
ELEVATIONS FROM VAULT B TO VAULT C..
B. ALL EM FIXTURES ARE FED FROM EXISTING
PANEL '7X' CIRCUIT 10.
C. REPLACE LIGHT FIXTURES ONE CIRCUIT AT
A TIME TO KEEP AS MANY LIGHTS ON AS
POSSIBLE DURING CONSTRUCTION.
D. REPLACE EXISTING CIRCUIT NUMBERS ON
WIRES IN J-BOXES WITH CORRECT CIRCUIT
NUMBERS.
E. CONTRACTOR TO SEAL AROUND CONDUIT
PENETRATION THROUGH TUNNEL
WALL/CEILING.
F. CLEAR OFF DEPOSITS ON EXISTING
CONDUIT.
Scale: 1/8" = 1'-0"
ENLARGED SITE PLAN - SEGMENT 2
ET-102-01
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
ET-102-02
ET-102-03
WP
'EPL-Q-VLTB-1'-
EM
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
SERVICE
CHASE S-2
MATCH LINE ET-103
MATCH LINE ET-102
MATCH LINE ET-104
MATCH LINE ET-103
BUILDING
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-103
ENLARGED SITE PLAN - SEGMENT 3
5 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NORTH
0 4 8 16
1 REPLACE EXISTING LIGHTING FIXTURES
WITH NEW. RETAIN EXISTING CIRCUIT FOR
NEW INSTALLATION. SEE DETAILS 1 AND 3 ON
E-501 FOR MORE INFORMATION.
2 GFI RECEPTACLE IS EXISTING TO REMAIN.
3 REPLACE 6’ OF 3/4" CONDUIT FOR
EMERGENCY CIRCUIT. PROVIDE 2 J-BOXES
FOR SPLICE CONNECTIONS. SEE DETAIL 3 ON
E-501 AND IMAGE ET-103-01 FOR MORE
INFORMATION.
4 REPLACE 5’ OF 1 1/2" CONDUIT FOR POWER.
SEE DETAIL 3 ON E-501 AND IMAGE ET-103-01
FOR MORE INFORMATION.
5 REPLACE 6' OF 2" CONDUIT FOR SPARE
CONDUIT. SEE DETAIL 3 ON E-501 AND IMAGE
ET-103-01 FOR MORE INFORMATION.
6 REPLACE 7’ OF 2” CONDUIT AND CONTROL
CABLING FOR FIRE ALARM. SEE DETAIL 3 ON
E-501 AND IMAGE ET-103-01 FOR MORE
INFORMATION.
7 REPLACE 16’ OF 1” EMT CONDUIT AND
CONTROL CABLING FOR JOHNSON
CONTROLS. SEE DETAIL 3 ON E-501 AND
IMAGE ET-103-01 FOR MORE INFORMATION.
8 REPLACE 8”X10”X4” J-BOX FOR POWER TO
LIGHT FIXTURE. REFER TO IMAGE ET-103-02
FOR MORE INFORMATION.
9 REPLACE 2’ OF 1” CONDUIT AND CONTROL
CABLING FOR JOHNSON CONTROLS.
PROVIDE 2 J-BOXES FOR SPLICE
CONNECTIONS. SEE DETAIL 3 ON E-501 AND
IMAGE ET-103-03 FOR MORE INFORMATION.
A. REFER TO DETAIL 3 ON E-501 FOR TYPICAL
ELEVATIONS FROM VAULT B TO VAULT C.
B. ALL EM FIXTURES ARE FED FROM EXISTING
PANEL '7X' CIRCUIT 10.
C. REPLACE LIGHT FIXTURES ONE CIRCUIT AT
A TIME TO KEEP AS MANY LIGHTS ON AS
POSSIBLE DURING CONSTRUCTION.
D. REPLACE EXISTING CIRCUIT NUMBERS ON
WIRES IN J-BOXES WITH CORRECT CIRCUIT
NUMBERS.
E. CONTRACTOR TO SEAL AROUND CONDUIT
PENETRATION THROUGH TUNNEL
WALL/CEILING.
F. CLEAR OFF DEPOSITS ON EXISTING
CONDUIT.
Scale: 1/8" = 1'-0"
ENLARGED SITE PLAN - SEGMENT 3
ET-103-02
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
ET-103-01
3 4 5 6 7
ET-103-03
3 4
7 8
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'PP-7' -
8,10,12
VENT SHAFT V-2
MANHOLE M-1
VAULT C
EF-1
MATCH LINE ET-104
MATCH LINE ET-103
MATCH LINE ET-105
MATCH LINE ET-104
BUILDING
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-104
ENLARGED SITE PLAN - SEGMENT 4
6 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NORTH
0 4 8 16
1 REPLACE EXISTING LIGHTING FIXTURES WITH
NEW. RETAIN EXISTING CIRCUIT FOR NEW
INSTALLATION. SEE DETAILS 1, 3, AND 4 ON
E-501 FOR MORE INFORMATION.
2 GFI RECEPTACLE IS EXISTING TO REMAIN.
3 REPLACE 10’ OF 3/4" EMT CONDUIT FOR FAN
CIRCUIT. SEE IMAGE ET-104-09 FOR MORE
INFORMATION.
4 REPLACE 15’ OF 1/2” EMT CONDUIT FOR FAN
STARTER/DISCONNECT WITH 3/4" EMT.
REPLACE 3 #12 CONDUCTORS. SEE IMAGE
ET-104-10 FOR MORE INFORMATION.
5 REPLACE 10’ OF 1” EMT CONDUIT AND
CABLING FOR JOHNSON CONTROLS. SEE
DETAIL 3 ON E-501 FOR MORE INFORMATION.
6 REPLACE 6”X6”X4” JOHNSON CONTROLS PULL
BOX AND CONTROL CABLING. REFER TO
IMAGE ET-104-01 FOR MORE INFORMATION.
7 REPLACE 6’ OF 2” EMT CONDUIT SERVING
FIRE ALARM CABLE WITH J-BOXES AND NEW
CONDUIT AND CABLING TO CONTINUE
CIRCUITRY.
8 REMOVE ALL RUST AND CORROSION FROM
EXISTING 2-4” RGS CONDUITS AND PAINT
WITH GRAY RUST INHIBITING PAINT. SEE
ARCHITECTURAL SHEETS AND REFER TO
IMAGE ET-104-02 FOR MORE INFORMATION.
9 REPLACE 6’ UNISTRUT SUPPORT WITH NEW.
REFER TO IMAGE ET-104-03 FOR MORE
INFORMATION.
10 REMOVE ALL RUST AND CORROSION FROM
EXISTING PULL BOX FOR CATV AND PAINT
WITH GRAY RUST INHIBITING PAINT. SEE
ARCHITECTURAL SHEETS AND REFER TO
IMAGE ET-104-03 FOR MORE INFORMATION.
11 REPLACE 20’ OF 1” EMT CONDUIT AND
CONTROL CABLING FOR JOHNSON
CONTROLS. SEE DETAIL 3 ON E-501 FOR
MORE INFORMATION.
12 REMOVE ALL RUST AND CORROSION FROM
EXISTING 2” CONDUIT AND PAINT WITH GRAY
RUST INHIBITING PAINT. SEE ARCHITECTURAL
SHEETS AND REFER TO IMAGE ET-104-04 FOR
MORE INFORMATION.
13 REMOVE ALL RUST AND CORROSION FROM
EXISTING AT&T PULL BOX AND PAINT WITH
GRAY RUST INHIBITING PAINT. SEE
ARCHITECTURAL SHEETS AND REFER TO
IMAGE ET-104-05 FOR MORE INFORMATION.
14 REPLACE FIRE ALARM PULL BOX WITH NEW.
PROVIDE REQUIRED SPLICING FOR RED WIRE
CONTROLLING ALARMS FOR NON-CRITICAL
SUMP PUMP. REFER TO IMAGE ET-104-06/07
AND DETAILS 5 AND 6 ON SHEET E-501 FOR
MORE INFORMATION.
15 PROVIDE SEALANT/CAULKING IN AND
AROUND VERTICAL CONDUIT. SEE IMAGE
ET-104-06 FOR MORE INFORMATION.
16 SUPPORT EXISTING SPLICE BOX AND
ADJACENT CONDUITS WITH UNISTRUT WALL
SUPPORTS. REMOVE RUST AND PAINT WITH
GRAY RUST INHIBITING PAINT. SEE IMAGE
ET-104-08 FOR MORE INFORMATION.
17 EF-1 DISCONNECT EXISTING TO REMAIN.
REFER TO IMAGE ET-104-09 FOR MORE
INFORMATION.
18 FAN HAND/OFF/AUTO SWITCH EXISTING TO
REMAIN. REFER TO IMAGE ET-104-10 FOR
MORE INFORMATION.
A. REFER TO DETAIL 3 ON E-501 FOR TYPICAL
ELEVATIONS FROM VAULT B TO C.
B. REFER TO DETAIL 4 ON E-501 FOR TYPICAL
ELEVATIONS FROM VAULT C TO BUILDING 7.
C. REPLACE LIGHT FIXTURES ONE CIRCUIT AT
A TIME TO KEEP AS MANY LIGHTS ON AS
POSSIBLE DURING CONSTRUCTION.
D. REPLACE EXISTING CIRCUIT NUMBERS ON
WIRES IN J-BOXES WITH CORRECT CIRCUIT
NUMBERS.
E. CONTRACTOR TO SEAL AROUND CONDUIT
PENETRATION THROUGH TUNNEL
WALL/CEILING.
F. CLEAR OFF DEPOSITS ON EXISTING
CONDUIT.
Scale: 1/8" = 1'-0"
ENLARGED SITE PLAN - SEGMENT 4
ET-104-01
ET-104-02
ET-104-03
ET-104-04
ET-104-05
ET-104-06
ET-104-07
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
ET-104-10
ET-104-09
ET-104-08
GFIWP
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
EM
MATCH LINE ET-105
MATCH LINE ET-104
MATCH LINE ET-106
MATCH LINE ET-105
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-105
ENLARGED SITE PLAN - SEGMENT 5
7 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NORTH
0 4 8 16
1 REPLACE EXISTING LIGHTING FIXTURES
WITH NEW. RETAIN EXISTING CIRCUIT FOR
NEW INSTALLATION. SEE DETAILS 1 AND 4 ON
E-501 FOR MORE INFORMATION.
2 GFI RECEPTACLE IS EXISTING TO REMAIN.
A. REFER TO DETAIL 4 ON E-501 FOR TYPICAL
ELEVATIONS FROM VAULT C TO BUILDING 7.
B. ALL EM FIXTURES ARE FED FROM EXISTING
PANEL '7X' CIRCUIT 10.
C. REPLACE LIGHT FIXTURES ONE CIRCUIT AT
A TIME TO KEEP AS MANY LIGHTS ON AS
POSSIBLE DURING CONSTRUCTION.
D. REPLACE EXISTING CIRCUIT NUMBERS ON
WIRES IN J-BOXES WITH CORRECT CIRCUIT
NUMBERS.
E. CONTRACTOR TO SEAL AROUND CONDUIT
PENETRATION THROUGH TUNNEL
WALL/CEILING.
F. CLEAR OFF DEPOSITS ON EXISTING
CONDUIT.
Scale: 1/8" = 1'-0"
ENLARGED SITE PLAN - SEGMENT 5
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
EXISTING
PANEL '7X'
3 4
5 6
SERVICE
CHASE S-3
VENT SHAFT V-3
EM
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
'EPL-Q-VLTB-1'-
EM
'EPL-Q-VLTB-1'-
EXISTING
PANEL 'PP-7'
VAULT D
MATCH LINE ET-106
MATCH LINE ET-105
BUILDING
BUILDING
'5X'- 5
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
ET-106
ENLARGED SITE PLAN - SEGMENT 6
8 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NORTH
0 4 8 16
1 REPLACE EXISTING LIGHTING FIXTURES
WITH NEW. RETAIN EXISTING CIRCUIT FOR
NEW INSTALLATION. SEE DETAILS 1 AND 4
ON E-501 FOR MORE INFORMATION.
2 GFI RECEPTACLE IS EXISTING TO REMAIN.
3 REPLACE 4’ OF 2” CONDUIT FOR FIRE
ALARM. REFER TO IMAGE ET-106-01 AND
DETAIL 4 ON E-501 FOR MORE INFORMATION.
4 REPLACE 4’ OF 2” CONDUIT FOR SPARE
CONDUIT. REFER TO IMAGE ET-106-01 AND
DETAIL 4 ON E-501 FOR MORE INFORMATION.
5 REPLACE 10’ OF 1” CONDUIT FOR JOHNSON
CONTROLS. REFER TO IMAGE ET-106-01 AND
DETAIL 4 ON E-501 FOR MORE INFORMATION.
6 REPLACE 5’ OF 3/4" CONDUIT FOR POWER
TO FAN. REFER TO IMAGE ET-106-01 AND
DETAIL 4 ON E-501 FOR MORE INFORMATION.
7 SHIFT OVER EXISTING PULL BOX AND
EXTEND EXISTING CABLING AS REQUIRED.
8 EXISTING JOHNSON CONTROLS SPLICE BOX
TO REMAIN. REFER TO IMAGE ET-106-03 FOR
MORE INFORMATION.
9 REPLACE 12”X12”X4” FIRE ALARM PULL BOX
WITH NEW ALONG WITH 2’ CONDUIT EACH
SIDE OF BOX. REFER TO IMAGE ET-106-04/05
AND DETAILS 5 AND 6 ON E-501 FOR MORE
INFORMATION.
10 REMOVE ALL RUST AND CORROSION FROM
EXISTING PULL BOX FOR CATV AND PAINT
WITH GRAY RUST INHIBITING PAINT. SEE
ARCHITECTURAL SHEETS FOR MORE
INFORMATION.
11 REMOVE ALL RUST AND CORROSION FROM
EXISTING PULL BOX FOR AT&T AND PAINT
WITH GRAY RUST INHIBITING PAINT. SEE
ARCHITECTURAL SHEETS FOR MORE
INFORMATION.
12 CLEAN RUST FROM CONDUIT, PAINT WITH
GRAY RUST INHIBITING PAINT, AND PROVIDE
SEALANT FROM CONDUIT PENETRATING
TUNNEL WALL. REFER TO IMAGES
ET-106-04/05 FOR MORE INFORMATION.
A. REFER TO DETAIL 4 ON E-501 FOR TYPICAL
ELEVATIONS FROM VAULT C TO BUILDING 7.
B. ALL EM FIXTURES ARE FED FROM EXISTING
PANEL '7X' CIRCUIT 10.
C. REPLACE LIGHT FIXTURES ONE CIRCUIT AT
A TIME TO KEEP AS MANY LIGHTS ON AS
POSSIBLE DURING CONSTRUCTION.
D. REPLACE EXISTING CIRCUIT NUMBERS ON
WIRES IN J-BOXES WITH CORRECT CIRCUIT
NUMBERS.
E. CONTRACTOR TO SEAL AROUND CONDUIT
PENETRATION THROUGH TUNNEL
WALL/CEILING.
F. CLEAR OFF DEPOSITS ON EXISTING
CONDUIT.
Scale: 1/8" = 1'-0"
ENLARGED SITE PLAN - SEGMENT 6
ET-106-01
ET-106-02
ET-106-03
ET-106-04
ET-106-05
3 4 5 6
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
NEW LOCATION
8 (BLK) 12 (BLU) 10 (RED)
1 1/2" C-3#12 CONTROL
3#6 POWER FOR RECEPTACLES
4#8 LIGHTING CKTS
1/2" SEALTITE - 2#12 & 1#12 GND (TYP)
2#10 & 1#10 GND
3/4"C (TYP)
J J J
F-1
GFI
EMERGENCY LIGHTING
LIGHTING AND POWER
SPARE
FIRE ALARM
AT&T
TELE
TELE
JOHNSON CONTROL
3/4" MC W/ 4"X4" J-BOX
1 1/2" C W/ 10"X8" J-BOX
2" C W/ 16"X24" J-BOX
2" C W/ 16"X24" J-BOX
4" C W/ 12"X48" J-BOX
1" (SCHED 80-PVC) INNER DUCT FIBER
4" C (SCHED 80-PVC)
4" C (SCHED 80-PVC)
1" C
BASIS OF DESIGN LIGHT FIXTURE
F-1, LITHONIA LIGHTING DMW2,
CAT. NO. DMW2 L24 4000LM PFL
MD MVOLT GZ1 40K 80CRI.
STEAM & WATER
8 OUT TO NEW TUNNEL
EXISTING 2" C
8 PAIRS OUT TO EXISTING TUNNEL
8 PAIRS IN FROM BLDG 113
REPLACE EXISTING PULL
BOX AND REPLACE WITH
NEW 8"DX14"X16" HOFFMAN
NEMA 4R ENCLOSURE
WITH HINGED DOOR
SPLICE EXISTING 12
GAUGE, 2 CONDUCTORS
FOR FIRE ALARM LOOP.
RETAIN PHENOLIC
LABELING
NEW TERMINAL STRIP
NEW JUMPERS
EXISTING 2" C
NEW TERMINAL BOX
EXISTING 2" C
8 PAIRS TO
BUILDING 5
REPLACE ALL EXISTING
BOX SUPPORTS WITH NEW
CLEAN RUST FROM CONDUIT. PAINT
WITH GRAY RUST INHIBITING PAINT.
PROVIDE SEALANT FROM CONDUIT
PENETRATING THE TUNNEL WALL.
BUILDING 7
JB3
JB4
JB5JB6JB8
JB7
JB9 JB10
TO BLDG 2 BY
EXISTING TUNNEL
TO BLDG 7
(FA BOARD)
VAULT D VAULT C
TO FIRE ALARM
PANEL IN BUILDING 5
TO HANDHOLE
FOR BLDG 4
AND OTHERS
VAULT B EXTERIOR
SUMP PUMP FLOAT
VAULT B
EYM, EYA,
EV1, EV2
TO BLDG 6 BY EXISTING TUNNEL
HIGHWATER ALARM
CONNECTED TO
PYROTRONICS
BUILDING 5
EYM, EYA,
EV1, EV2
3/4" C
3/4" C
TO GRAPHICS
BY MANHOLES
EYA, EYM, EV1,
EV2, DYA, DYM,
DV1, DV2
HIGHWATER
ALARM 5 IN PIT,
CONNECTED TO
FIRE ALARM
PANEL IN BLDG 5
EYM, EYA,
EV1, EV2
DYM, DYA,
DV1, DV2
DYM
DYA
EYM
EYA
COM LINE E - 2, 3, 4, 6, 7, 12
COM LINE D - 1, 20, 41, 97, 107, 108
1, 20, 97, 107, 108
3, 4
F-1
GFI
EMERGENCY LIGHTING
LIGHTING AND POWER
SPARE
FIRE ALARM
AT&T
TELE
TELE
JOHNSON CONTROL
3/4" MC W/ 4"X4" J-BOX
1 1/2" C W/ 10"X8" J-BOX
2" C W/ 16"X24" J-BOX
2" C W/ 16"X24" J-BOX
4" C W/ 12"X48" J-BOX
1" (SCHED 80-PVC) INNER DUCT FIBER
4" C (SCHED 80-PVC)
4" C (SCHED 80-PVC)
1" C
STEAM & WATER
3/4" C, EF-1 CIRCUIT
BASIS OF DESIGN LIGHT FIXTURE
F-1, LITHONIA LIGHTING DMW2,
CAT. NO. DMW2 L24 4000LM PFL
MD MVOLT GZ1 40K 80CRI.
F-1
GFI
EMERGENCY LIGHTING
LIGHTING AND POWER
BASIS OF DESIGN LIGHT FIXTURE
F-1, LITHONIA LIGHTING DMW2,
CAT. NO. DMW2 L24 4000LM PFL
MD MVOLT GZ1 40K 80CRI.
STEAM
2" PVC
BLDG 43 CONDENSER PUMP 1" EMT
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:1
A
M C
U s e rs \j g o s s e tt \D o c u m e n ts \E
-1
-V
A M ilw a u k e e
-S te a m
T u n n e l R e p r_ jg o s s e tt M
K V
T K
.r v t
E-501
ELECTRICAL DETAILS
9 9JHG
REPAIR NORTH CAMPUS
STEAM TUNNEL
CLEMENT J. ZABLOCKI VAMC
5000 WEST NATIONAL AVENUE
MILWAUKEE, WI 53295 JULY 14, 2023
100% BID DOCUMENTS
695-21-11022-177-Q30
N/A
KTK
NOTES:
TOTAL DEMAND AMPS: 3 A
TOTAL DEMAND LOAD: 1.26 kVA
CONNECTED AMPS: 3 A
CONNECTED LOAD: 1.26 kVA
LIGHTING (GENERAL) 0.00 kVA 0.00% 0.00 kVA
RECEPTACLES (GENERAL) 1.26 kVA 100.00% 1.26 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS
TOTAL AMPS: 3 A 5 A 3 A
TOTAL LOAD: 0.36 kVA 0.54 kVA 0.36 kVA
29 0.00 -- 1 -- SPACE 30
27 0.00 -- 1 -- SPACE 28
MAIN 60 A 3
0.00 -- 1 -- SPACE 26
23 0.00 -- 1 -- SPACE 24
21 0.00 -- 1 -- SPACE 22
SUMP 15 A 3
0.00 0.00 20
17 SPACE -- 1 -- 0.00
2 20 A PARKING LOT LIGHTS
15 SPACE -- 1 -- 0.00 1 20 A WEST RECPT 16
13 TUNNEL 43 RECPT (NEW) 20 A 1 0.36 0.00 1 20 A CONDENSER PUMP BLO 43 14
11 NEW CORRIDOR RECPT 20 A 1 0.00 0.00 1 20 A TUNNEL CKT 6 LIGHTING 12
9 NEW CORRIDOR RECPT 20 A 1 0.00 0.00 1 20 A TUNNEL CKT 10 LIGHTING 10
7 NEW CORRIDOR RECPT 20 A 1 0.00 0.00 1 20 A TUNNEL CKT 8 LIGHTING 8
5 FLYGHT PUMP 20 A 1 0.00 0.36 1 20 A TUNNEL CKT 12 RECPT 6
3 SUMP RECPT 20 A 1 0.00 0.54 1 20 A TUNNEL CKT 9 RECPT 4
1 SUMP RECPT 20 A 1 0.00 0.00 1 20 A VAULT B & TUNNEL 43 LIGHTS 2
CKT CIRCUIT DESCRIPTION TRIP POLE A B C A B C POLE TRIP CIRCUIT DESCRIPTION CKT
ENCLOSURE: NEMA 1 SHORT CIRCUIT RATING: 10,000 AMPS SYMMETRICAL
MOUNTING: SURFACE MAINS, TYPE: 100 A MAIN CB
BRANCH: CRITICAL PHASE CREATED: Existing VOLTAGE: 120/208V, 3PH, 4W
PANEL: EPL-Q-VLTB-1
NOTES:
TOTAL DEMAND AMPS: 0 A
TOTAL DEMAND LOAD: 0.00 kVA
CONNECTED AMPS: 0 A
CONNECTED LOAD: 0.00 kVA
LIGHTING (GENERAL) 0.00 kVA 0.00% 0.00 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS
TOTAL AMPS: 0 A 0 A 0 A
TOTAL LOAD: 0.00 kVA 0.00 kVA 0.00 kVA
29 0.00 -- 1 -- SPACE 30
27 0.00 0.00 28
PANEL 5X 50 A 3
0.00 0.00 26
23 SOUTH EM LIGHTING 20 A 1 0.00 0.00
3 20 A COMPRESSOR
21 SPARE 20 A 1 0.00 0.00 22
19 SPARE JCI PANEL B-9 20 A 1 0.00 0.00 20
17 SPARE 20 A 1 0.00 0.00
3 20 A SPARE
15 3RD FLR EM LIGHTING 20 A 1 0.00 0.00 1 20 A DOOR OPENER 16
13 3RD FLR EM LIGHTING 20 A 1 0.00 0.00 1 20 A ELEVATOR CAB LIGHT 14
11 3RD FLR EM LIGHTING 20 A 1 0.00 0.00 1 20 A BLDG 7 BASEMENT LIGHTING 12
9 0.00 0.00 1 20 A TUNNEL EM LIGHTING 10
AIR COMPRESSOR 20 A 2
0.00 0.00 1 20 A SPARE 8
5 BASEMENT EM LIGHTING 20 A 1 0.00 0.00 1 20 A SUMP PUMP BLDG 7 PIT 6
3 BASEMENT EM LIGHTING 20 A 1 0.00 0.00 1 20 A FACP 4
1 SPARE 20 A 1 0.00 0.00 1 20 A JC PANEL 2
CKT CIRCUIT DESCRIPTION TRIP POLE A B C A B C POLE TRIP CIRCUIT DESCRIPTION CKT
ENCLOSURE: NEMA 1 SHORT CIRCUIT RATING: 10,000 AMPS SYMMETRICAL
MOUNTING: SURFACE MAINS, TYPE: 100 A MAIN CB
BRANCH: EMERGENCY PHASE CREATED: Existing VOLTAGE: 120/208V, 3PH, 4W
PANEL: 7X
Scale: No Scale
NORMAL TYPICAL LIGHTING FIXTURE/RECEPTACLE INSTALLATION
Scale: No Scale
TYPICAL EXISTING ELEVATION THROUGH STEAM TUNNEL VAULT B TO VAULT C
Scale: No Scale
NEW FIRE ALARM TERMINAL BOX REPLACEMENT DETAIL
Scale: No Scale
EXISTING FIRE ALARM LOOP DIAGRAM
Scale: No Scale
TYPICAL EXISTING ELEVATION THROUGH STEAM TUNNEL VAULT C TO BUILDING 7
Scale: No Scale
TYPICAL EXISTING ELEVATION THROUGH STEAM TUNNEL VAULT B TO BLDG 43
| 1-Gen 22-177 100% to VA |
| 2-Civil 22-177 100% to VA |
| CD101 CIVIL DEMOLITION PLAN |
| CS101 CIVIL SITE, GRADING, AND UTILITY PLAN |
| CS501 CIVIL DETAILS |
| 3-Struct 22-177 100% to VA |
| S-001 GENERAL NOTES |
| S-002 EXISTING CONDITIONS PHOTOS |
| S-100 VAULT B RISER S-1 PLAN |
| S-101 VAULT C RISER S-2 PLAN |
| S-102 NORTH TUNNEL PLAN |
| S-103 VAULT D RISER S-3 PLAN |
| S-104 SPUR TUNNEL PLAN |
| S-200 REPAIR DETAILS |
| 4-Arch 22-177 100% to VA |
| 5-Elec 22-177 100% to VA |
| E-001 - ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS |
| ET-100 - ELECTRICAL SITE PLAN |
| ET-101 - ENLARGED SITE PLAN - SEGMENT 1 |
| ET-102 - ENLARGED SITE PLAN - SEGMENT 2 |
| ET-103 - ENLARGED SITE PLAN - SEGMENT 3 |
| ET-104 - ENLARGED SITE PLAN - SEGMENT 4 |
| ET-105 - ENLARGED SITE PLAN - SEGMENT 5 |
| ET-106 - ENLARGED SITE PLAN - SEGMENT 6 |
| E-501 - ELECTRICAL DETAILS |
File details come from the government source that posted it. Updated .