Revised Bldg 10 Floor plan.pdf
PDF 475 KB Posted
- Attached to
- Y1AZ--Renovate Building Number 10 Veterans Benefits Administration Office Space, West Palm Beach, FL.
- Solicitation number
- 36C10E21R0006
About this file
This pre-solicitation notice provides an overview of a forthcoming solicitation for renovation services. The Department of Veterans Affairs Veteran Benefits Administration will issue a solicitation to renovate approximately 1,900 square feet of office space at their West Palm Beach, Florida facility for $500,000 to $1,000,000. Renovations will include demolition, construction, electrical, HVAC, data/voice, and interior finish work. The solicitation number is 36C10E21R0006 and offers are due by July 16, 2021. The contract will be a firm-fixed price award to a verified Service-Disabled Veteran Owned Small Business set aside for this requirement. The period of performance is expected to be approximately 90 days following a notice to proceed.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
AREA PLAN LEGEND
KEY NOTES
F E
C
24/48WB24/48WB
H K
O
B
.P
F
H K
O
B
.P
F
HK9OB30.P1F
24/48WB 24/48WB 24/48WB
BARRIER LEGEND
1. CONTRACTOR TO FIELD VERIFY EXISTING
STRUCTURAL COLUMN SPACING AND OVERALL
BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY
VA AND ARCHITECT IF ANY DISCREPANCIES ARE
FOUND BETWEEN FIELD DIMENSIONS AND
DRAWINGS.
2. GENERAL CONTRACTOR (GC) SHALL VERIFY
DIMENSIONS OF OWNER FURNISHED EQUIPMENT
AND COORDINATE INSTALLATION WITH ALL
TRADES WHERE REQUIRED.
3. REFER TO FINISH SHEETS FOR PARTITION
PROTECTION INFORMATION INCLUDING BUT NOT
LIMITED TO ALL CORNER GUARD TYPES AND
LOCATIONS.
4. GENERAL CONTRACTOR (GC) SHALL INSTALL
IN-WALL 16 GA METAL BACKING FOR ALL
PARTITION-MOUNTED EQUIPMENT, ACCESSORIES,
PARTITION STOPS, ETC.
5. GENERAL CONTRACTOR (GC) SHALL INSTALL
FIRE-RETARDANT WOOD BLOCKING WITHIN WALLS
BASED ON CASEWORK ELEVATIONS AND ALL
INTERIOR PARTITION ELEVATIONS.
6. ALL INTERIOR WALLS SHALL RECEIVE
5/8" TYPE 'X' GYPSUM BOARD.
7. GENERAL CONTRACTOR (GC) SHALL PROVIDE
UL APPROVED FIRE-RESISTIVE PENETRATION
SYSTEMS AT ALL FIRE- RATED PARTITION
ASSEMBLY.
8. ALL CORRIDOR WALLS SHALL BE CONSTRUCTED
AS NON-RATED SMOKE PARTITIONS.
9. ALL WALLS SHALL BE CONSTRUCTED FLOOR TO
DECK AND CONTAIN SOUND INSULATION AND
ACOUSTICAL CAULK. REFER TO 10-AF103 FOR
INTERIOR PARTITION TYPES & DETAILS.
10. REFER TO SHEET 1-AE703 FOR RATED PARTITION
DETAILS AND RATED PARTITION INTERSECTIONS.
11. PROVIDE 16 GA STUDS ON WET WALLS IN
RESTROOMS AND FOR THE DRINKING FOUNTAIN
WALL. 20 GA STUDS ON ALL OTHER WALLS.
AREA WITHIN SCOPE OF WORK = 1,945 SQUARE FEET
AREA NOT IN CONTRACT
KEY PLAN
AREA OF
WORK
230 SF
LOBBY/WAITING
118 SF
OFFICE
118 SF
OFFICE
118 SF
OFFICE
160 SF
CORRIDOR
20 SF
ELEC
CLOSET
430 SF
WORK AREA
54 SF
COPIER/SUPPLIES
111 SF
SUPERVISOR
OFFICE
231 SF
CONFERENCE ROOM
HATCHED AREA NOT IN
PROJECT SCOPE
22222
3 4
5 6
3 4
5 6
3 4
5 6
3 4
5 6
3 4
5 6 3 4
5 6
3 4
5 6
3 4 5
128B130B131B
135A
131A 130A 128A
112 SF
OFFICE
135B
A
134B
A
46 SF
CORRIDOR
13 14
16 1716 17 17
1111 11 11
12 13 14
8 7
3 4 5
6 87
3 4
5 6
3 4
5 6
7 8
AE501
SB1 = SMOKE BARRIER (WALL TYPE R3)
NON-RATED INTERIOR PARTITION WALL (WITH
INSULATION)
EXISTING WALL TO REMAIN
SEE AF103 FOR WALL TYPE CONSTRUCTION
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
Spinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
B
IM
/V
B A
W
P B
B u ild in g
R e n o v a ti o n
D e s ig n /W
P B
B u ild in g
R e n o v a ti o n
V
.r v t
/2
/2
:1
:1
A
M
MK EM
VB3239
AE102
548 - WEST PALM BEACH
APRIL 12, 2021
10-
ENLARGED FIRST FLOOR PLAN 100% CONSTRUCTION
DOCUMENT SUBMISSION
WEST PALM BEACH BLDG. 10
RENOVATION
Note Number Note
1 EXISTING DOOR AND DOOR FRAME TO REMAIN.
2 EXISTING WINDOWS TO REMAIN.
3 PATCH, CLEAN, AND REPAIR WALLS AFTER DEMO TO MATCH ADJACENT
SURFACES. TYPICAL IN ALL AREAS.
4 PATCH, CLEAN, AND REPAIR FLOORS WHERE NEEDED AFTER DEMO. LEVEL
FLOORS WHERE NEEDED. TYPICAL IN ALL AREAS.
5 PAINT NEW WALLS. SEE FINISH MATERIAL SCHEDULE AF102 FOR DETAILS.
TYPICAL IN ALL AREAS.
6 INSTALL NEW CEILING GRID AND CEILING TILES. SEE REFLECTED CEILING
PLAN AE120 FOR DETAILS. TYPICAL IN ALL AREAS.
7 GYPSUM BOARD FROM EXISTING WALL PARTITION ASSEMBLIES TO
REMAIN. PATCH AND REPAIR EXISTING WALL TO ACCEPT NEW
FINISHES.REFER TO FINISH SCHEDULE SHEET 10-AF102 FOR NEW
FINISHES.
8 PROVIDE NEW FLOORING & NEW FLOORING FINISHES. SEE FINISH
MATERIAL SCHEDULE SHEET AF102 FOR MORE INFORMATION.
9 SOLID SURFACE COUNTERTOP AND UPPER CABINETS. SEE MILLWORK
SHEET AE501 FOR DETAILS.
10 CORNER GUARD WALL PROTECTION (6'-0" STARTING AT TOP OF BASE) TYP.
ALL CORRIDOR CORNERS AS NOTED ON PLANS - REFER TO SPECS FOR
DETAILS.
11 PROVIDE CARD READER, POWER SUPPLY, AND DOOR CONTACT FOR EACH
DOOR ASSEMBLY AND INCORPORATE/TIE-IN ALL COMPONENTS TO THE
EXISTING ACCESS CONTROL SYSTEM SO THAT IT IS OPERATIONAL PRIOR
TO SUBSTANTIAL COMPLETION. SEE SHEET ET101 ELECTRICAL SHEET FOR
MORE INFORMATION.
12 PROVIDE AUTOMATIC DOOR OPENING SYSTEM PUSH PANEL. SEE SHEET
ET101 ELECTRICAL SHEET FOR MORE INFORMATION.
13 PROVIDE REQUEST EXIT PUSH BUTTON. SEE SHEET ET101 ELECTRICAL
SHEET FOR MORE INFORMATION.
14 PROVIDE PASSIVE INFRARED SENSOR. SEE SHEET ET101 ELECTRICAL
SHEET FOR MORE INFORMATION.
15 PROVIDE DOOR BELL. SEE SHEET ET101 ELECTRICAL SHEET FOR MORE
INFORMATION.
16 PROVIDE NEW MOTORIZED ROLLER SHADES WITH 20% OPACITY AND
BLACKOUT SHADE REFER TO SPEC FOR PRODUCT INFORMATION.
17 PROVIDE NEW MANUALLY OPERATED ROLLER SHADE WITH 205 OPACITY.
REFER TO SPEC FOR PRODUCT INFORMATION.
PLAN NORTH
1/4" = 1'-0"
ENLARGED FIRST FLOOR PLAN
Revisions: Date:
| Sheets |
| AE102 - ENLARGED FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .