VBA B10_E500 Electrical One-Line Diagram and Schedules - Addendum 1.pdf

PDF 229 KB Posted

Attached to
Y1AZ--Renovate Building Number 10 Veterans Benefits Administration Office Space, West Palm Beach, FL.
Solicitation number
36C10E21R0006
Issued by

About this file

This pre-solicitation notice describes an upcoming solicitation for renovation services. The Department of Veterans Affairs Veteran Benefits Administration will solicit offers to renovate approximately 1,900 square feet of office space at the Veterans Affairs Medical Center in West Palm Beach, Florida. Renovations will include demolishing existing systems and installing new electrical, HVAC, data/voice, and interior finishes. The estimated value is between $5-10 million. The solicitation number will be 36C10E21R0006, and offers will be due on July 16, 2021. The contract will be a single-award firm-fixed-price contract awarded based on price, technical approach, and past performance. The project must be completed within 90 days of the notice to proceed. The solicitation will be set aside for a total service-disabled veteran-owned small business and will use NAICS code 236220 with a size standard of $36.5 million. The pre-solicitation notice provides contact information for any questions.

View the file

Other files

File Type Posted
36C10E21R0006 0009.docx DOCX document
36C10E21R0006 0008.docx DOCX document
Bldg 10 Fire Alarm.pdf PDF
2021-0811_RFI Responses VBA B10.pdf PDF
36C10E21R0006 0007.docx DOCX document
36C10E21R0006 0006.docx DOCX document
36C10E21R0006 0005.docx DOCX document
Electrical Pages from Bldg 10 Asbuilts.pdf PDF
230923 DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC_Addendum 1.pdf PDF
2021-0730 VBA B10 Addendum 1 Narrative.pdf PDF
VBA B10_MH101 First Floor Partial Plan HVAC - Addendum 1.pdf PDF
VBA B10_MH400 HVAC Schedules - Addendum 1.pdf PDF
VBA B10_EL101 First Floor Partial Plan Lighting - Addendum 1.pdf PDF
2021-0709 100_ Final CDs WPB Bldg 10 VBA3239_SPECS VOL2.pdf PDF
2021-0730 VBA B10 RFI Responses.pdf PDF
36C10E21R0006 0004.docx DOCX document
36C10E21R0006 0003.docx DOCX document
2021-0709 100 Final CDs WPB Bldg 10 VBA3239_SPECS VOL1.pdf PDF
000115 LIST OF DRAWING SHEETS.pdf PDF
2021-0709 WPB Drawings 100_ Final CDs.pdf PDF
36C10E21R0006 0002.docx DOCX document
S06-Construction Wage Determination FL20210220.pdf PDF
36C10E21R0006 0001.docx DOCX document
PROJECT NARATIVE.pdf PDF
PROJECT-VBA3239_DRAWINGS.pdf PDF
Bldg 10 VBA3239_SPECS VOL2.pdf PDF
Revised Bldg 10 Floor plan.pdf PDF
Wage Decision FL20200222.pdf PDF
36C10E21R0006_1.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

' 6

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V B

A

W P

B B u ild in g

R e n o va tio n D e si g n /W

P B

B u ild in g

R e n o va tio n

V

M E

P .r vt

/3

/2

:1

:5

P

M

JK DAW

VB3239

E-500

548 - WEST PALM BEACH

JULY 9, 2021

10-

ELECTRICAL ONE-LINE DIAGRAM AND

SCHEDULES

100% FINAL CONSTRUCTION

DOCUMENTS

WEST PALM BEACH BLDG. 10

RENOVATION

EXT ISOLITE ELT-EM-G-1M/2M-BA-SC/SW-UC-SD - OR APPROVED EQUAL UNV 5 LED

SINGLE FACE EDGE LIT EXIT SIGN, UNIVERSAL MOUNT, CHEVRONS AS INDICATED ON PLANS, FACE AS INDICATED ON PLANS, MOUNT AS

INDICATED ON PLANS, PROVIDE WITH MIRROR BACKING AND SELF TESTING BATTERY PACK

C1 COLUMBIA LCL4-35HL-E-U-ELL14-PAF - OR APPROVED EQUAL UNV 52 LED

4.5"W X 4'L ACRYLIC LENSED SURFACE MOUNTED LED STRIP FIXTURE, MOUNTED AT 6" ABOVE DOOR FRAME AND CENTERED IN SPACE, MIN 6,300 LUMENS, 50,000 HOURS AT L70, 1400 LUMEN EMERGENCY BATTERY PACK

B1 CLS A4-RM-10-EL2-35-50 - OR APPROVED EQUAL UNV 10 LED 6" ROUND RECESSED LED DOWNLIGHT, 1% DIMMING, 90CRI, 50,000 HRS AT L70

A11 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-2EM-1-3-5-7-28FT - OR APPROVED EQUAL UNV 132 LED 2.64"W X 4.5"H X 28'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F. W/3 EMERGENCY BATTERY PACKS.

A10 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-2EM-1-3-5-24FT - OR APPROVED EQUAL UNV 132 LED 2.64"W X 4.5"H X 24'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F. W/3 EMERGENCY BATTERY PACKS.

A9 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-2EM-1-3-5-20FT - OR APPROVED EQUAL UNV 110 LED 2.64"W X 4.5"H X 20'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F. W/3 EMERGENCY BATTERY PACKS.

A8 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-2EM-1-4-8FT - OR APPROVED EQUAL UNV 88 LED 2.64"W X 4.5"H X 8'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F. W/2 EMERGENCY BATTERY PACKS.

A7 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-2EM-2-3-16FT - OR APPROVED EQUAL UNV 88 LED 2.64"W X 4.5"H X 16'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F. W/2 EMERGENCY BATTERY PACKS.

A6 FOCAL POINT FSM2BS-BWFL-500DN-250UP-935K-1C-UNV-DLM1-C24-12FT - OR APPROVED EQUAL UNV 66 LED 2.64"W X 4.5"H X 12'L DIRECT INDIRECT LINEAR PENDEANT WITH 500 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP

LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F.

A5 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-12FT - OR APPROVED EQUAL UNV 66 LED 2.64"W X 4.5"H X 12'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP

LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F.

A4 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-2EM-1-3-6FT - OR APPROVED EQUAL UNV 66 LED 2.64"W X 4.5"H X 6'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F. W/2 EMERGENCY BATTERY PACKS.

A3 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-8FT - OR APPROVED EQUAL UNV 44 LED 2.64"W X 4.5"H X 8'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP

LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F.

A2 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-4FT - OR APPROVED EQUAL UNV 33 LED 2.64"W X 4.5"H X 4'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP

LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F.

A1 FOCAL POINT FSM2BS-BWFL-375DN-250UP-935K-1C-UNV-DLM1-C24-4FT - OR APPROVED EQUAL UNV 22 LED 2.64"W X 4.5"H X 4'L DIRECT INDIRECT LINEAR PENDEANT WITH 375 LUMENS PER FOOT DOWN LIGHT AND 250 LUMENS PER FOOT UP

LIGHT, 90 CRI, 1% DIMMING, 61,000 HRS AT L70, SUSPENDED AT 7'-6" A.F.F.

TYPE MANUFACTURER MODEL VOLTAGE INPUT WATTS LAMP DISCRIPTION

LIGHT FIXTURE SCHEDULE

Revisions: Date:

Addendum #1 7.16.21

Sheets
E-100 - ELECTRICAL LEGEND AND ABBREVIATIONS
E-400 - ELECTRICAL DETAILS
ED101 - PARTIAL GROUND FLOOR PLAN - LIGHTING DEMOLITION
ED102 - PARTIAL GROUND FLOOR PLAN - POWER & SYSTEMS DEMOLITION
EL101 - FIRST FLOOR PARTIAL PLAN - LIGHTING
EP101 - FIRST FLOOR PARTIAL PLAN - POWER
EP102 - FIRST FLOOR PARTIAL PLAN - MECHANICAL POWER
ET101 - FIRST FLOOR PARTIAL PLAN - ELECTRICAL SYSTEMS
FD101 - FIRST FLOOR PARTIAL PLAN - SPRINKLER DEMOLITION
FS100 - SPRINKLER LEGEND, DETAILS, SCHEDULES, AND ABBREVIATIONS
FS101 - FIRST FLOOR PARTIAL PLAN - SPRINKLER
M-100 - MECHANICAL LEGEND AND ABBREVIATIONS
MD101 - FIRST FLOOR PARTIAL PLAN - HVAC DEMOLITION
MH101 - FIRST FLOOR PARTIAL PLAN - HVAC
MH300 - HVAC DETAILS
MH400 - HVAC SCHEDULES
E-500 - ELECTRICAL ONE-LINE DIAGRAM AND SCHEDULES