REVISED ATTACHMENT C PLANS AND DRAWINGS Prineville Reservoir State Park Jasper Point Cabin Project.pdf
PDF 19 MB Posted
- Solicitation number
- S-63400-00012488
- Issued by
- Crook County, Portland City, Oregon
About this file
Structural Plans and Specifications for Prineville Reservoir State Park Deluxe Cabin
This document comprises the structural notes, foundation plans, framing details, and mechanical, plumbing, and electrical specifications prepared by VLMK Architects for the Oregon Parks and Recreation Department's Prineville Reservoir State Park Deluxe Cabin Project (OPRIS #1032437551; Contract #1224936729) in Prineville, Oregon. The project involves construction of a new accessible cabin facility incorporating site preparation, foundation work, structural framing, and integrated building systems. The design incorporates Douglas Fir lumber framing, concrete foundations with specific reinforcement schedules, and engineered connections per Simpson Strong-Tie specifications. Structural systems include light frame wood shear walls with capacities ranging from 310 to 600 PLF (seismic) and 435 to 840 PLF (wind), all designed in accordance with the 2022 Oregon Structural Specialty Code based on the 2021 International Building Code. Foundation requirements specify minimum 18-inch depth below final grade on firm soil with 1,500 PSF design pressure, while floor and roof systems are sized for 40 PSF and 75 PSF live loads respectively, with 25 PSF snow load requirements. Plumbing systems include domestic hot and cold water distribution via cross-linked polyethylene tubing, electric water heater capacity of 40 gallons with 25 GPH recovery, and fixture counts of four water closets, two showers, two lavatories, and two sinks. Mechanical systems incorporate a mini-split heat pump system (18 MBH cooling/22 MBH heating capacity) with energy recovery ventilation and electric cove heating for supplemental warmth, while electrical systems include a 100-ampere panelboard with circuits for interior and exterior lighting, equipment connections, and appliance loads.
Special inspection and materials testing requirements mandate continuous or periodic inspection of concrete placement, reinforcing steel installation, adhesive anchor placement, roof and wall diaphragm nailing, and prefabricated structural elements, with all inspections to be performed by an accredited testing laboratory and reported with professional stamps. The specifications require compliance with ASTM standards for concrete mixes (3,000 PSI minimum strength), reinforcing steel (ASTM A615 Grade 60), and all hardware connections, with post-installed anchors limited to Simpson, Hilti, or equivalent products pre-approved by the engineer. Corrosion protection requirements include hot-dip galvanized fasteners per ASTM A153 for all exterior and pressure-treated lumber applications, while all concrete mixes must incorporate water-reducing agents and air entrainment where specified. The design establishes seismic design category D with mapped spectral accelerations (Ss = 0.323; S1 = 0.163) and wind design speeds of 110 MPH ultimate and 85 MPH nominal. Construction coordination requirements emphasize verification of all dimensions and field conditions prior to fabrication, notification of the engineer 24 hours before required inspections, and submittal of shop drawings for all structural products in PDF format with engineer review and markup within two weeks.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL NOTES
OPRD - PRINEVILLE RESERVOIR STATE PARK DELUXE CABIN - VLMK JOB #20240088
DIVISION 1 - GENERAL
A. GENERAL
1. THESE DRAWINGS HAVE BEEN PREPARED SOLELY FOR USE IN THE CONSTRUCTION OF:
A. OREGON PARKS AND RECREATION DEPARTMENT, PRINEVILLE RESERVOIR STATE PARK.
B. PRINEVILLE RESERVOIR STATE PARK, JUNIPER CANYON RD., PRINEVILLE, OR 97754.
C. POSSESSION OF THESE DRAWINGS DOES NOT GRANT A LICENSE TO CONSTRUCT OR
FABRICATE THE WHOLE, OR PARTS OF THIS PROJECT IN OTHER LOCATIONS.
2. THESE NOTES SET MINIMUM STANDARDS FOR CONSTRUCTION. THE DRAWINGS GOVERN OVER
THE GENERAL NOTES TO THE EXTENT SHOWN.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON DRAWINGS AND IN FIELD.
COORDINATE LOCATIONS OF OPENINGS THROUGH FLOORS, ROOFS AND WALLS WITH
ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. NOTIFY ENGINEER OF ANY
DISCREPANCIES OR IF ACTUAL CONDITIONS DIFFER FROM THOSE SHOWN OR NOTED.
4. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF ALL
TEMPORARY BRACING, SHORING, ANCHORS, ETC., INCLUDING, BUT NOT LIMITED TO, WALL AND ROOF BRACING, LIFTING AND HANDLING INSERTS AND DEVICES, TRENCH SHORING, FORMS, ETC.
5. CONTRACTOR SHALL CONSIDER CONSTRUCTION LOADS WHENEVER SUCH LOADS ARE IN EXCESS OF NORMAL DESIGN LOADS. PARTICULAR ATTENTION SHOULD BE GIVEN TO CRANES, FORKLIFTS, WORKMAN, WHEEL LOADS, STORAGE OF MATERIALS, ETC. CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR ALL SHORING, BRACING, CRIBBING, ETC. REQUIRED TO SUPPORT
CONSTRUCTION LOADS.
6. INSPECTION AND/OR JOB SUPERVISION IS NOT PROVIDED BY ENGINEER.
7. WHERE REFERENCE IS MADE TO ASTM, AISC, ACI, ASCE OR OTHER STANDARDS, THE LATEST
ISSUE SHALL APPLY.
8. ALL WORK SHALL BE IN STRICT COMPLIANCE WITH:
A. 2022 OREGON STRUCTURAL SPECIALTY CODE.
(BASED ON THE 2021 INTERNATIONAL BUILDING CODE)
B. ALL OTHER STATE AND LOCAL BUILDING REQUIREMENTS THAT APPLY.
9. DESIGN CRITERIA:
a. FLOOR LIVE LOADS (PER IBC 1603.1.1)
CABIN FLOOR 40 PSF
b. ROOF LIVE LOADS (PER IBC 1603.1.2)
MINIMUM 20 PSF
c. ROOF SNOW LOAD (PER IBC 1603.1.3)
FLAT-ROOF SNOW LOAD (Pf) 25 PSF SNOW DRIFT SURCHARGE AND WIDTH (Pd, W) SEE DWGS SNOW EXPOSURE FACTOR (Ce) 1.0 SNOW LOAD IMPORTANCE FACTOR (Is) 1.0 THERMAL FACTOR (Ct) 1.0
d. WIND LOAD (PER IBC 1603.1.4) ULTIMATE DESIGN WIND SPEED (Vult) 110 MPH NOMINAL DESIGN WIND SPEED (Vasd) 85 MPH
RISK CATEGORY II
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT (GCpi) ±0.18
e. EARTHQUAKE DESIGN DATA (PER IBC 1603.1.5) SEISMIC IMPORTANCE FACTOR (Ie) 1.0
RISK CATEGORY II
MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss = 0.323 S1 = 0.163 SITE CLASS D (default) DESIGN SPECTRAL RESPONSE COEFFICIENTS Sds = 0.332 Sd1 = 0.247
SEISMIC DESIGN CATEGORY D
BASIC SEISMIC-FORCE-RESISTING SYSTEM LIGHT FRAME WOOD SHEAR WALLS
ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCE
10. MECHANICAL EQUIPMENT, MECHANICAL AND SPRINKLER PIPING LARGER THAN 2 INCHES IN
DIAMETER OR ANY OTHER ITEMS PRODUCING A HANGER OR SUPPORT LOAD OF OVER 50
POUNDS SHALL BE HUNG BY A SYSTEM APPROVED BY ENGINEER. ANY HANGER OR SUPPORT
PRODUCING A LOAD OVER 200 POUNDS SHALL HAVE ADDITIONAL FRAMING INSTALLED TO
TRANSFER THESE LOADS TO THE MAIN STRUCTURAL BEAMS OR WALL UNLESS OTHERWISE
APPROVED.
11. WHERE REQUIRED, SEISMIC BRACING FOR MECHANICAL AND ELECTRICAL EQUIPMENT,
SPRINKLER PIPING OR OTHER NON-STRUCTURAL COMPONENTS SHALL BE PROVIDED BY THE
CONTRACTOR IN ACCORDANCE WITH CHAPTER 13 OF ASCE 7. STRUCTURAL CALCULATIONS AND
DETAILS STAMPED BY A LICENSED ENGINEER SHALL BE SUBMITTED TO ENGINEER FOR REVIEW.
12. PROVIDE SHOP DRAWINGS FOR ALL STRUCTURAL PRODUCTS DELIVERED TO THE PROJECT.
ENGINEER WILL REVIEW AND MARK-UP ELECTRONIC SUBMITTALS IN PDF FORMAT OR A MAXIMUM
OF THREE HARD COPIES OF SUBMITTALS. THE CONTRACTOR WILL BE RESPONSIBLE FOR
DUPLICATING MARK-UPS IF ADDITIONAL COPIES ARE REQUIRED. SUBMITTALS WILL BE REVIEWED
AND RETURNED TO THE GENERAL CONTRACTOR WITHIN TWO WEEKS. ALL SUBMITTALS SHALL BE
REVIEWED AND STAMPED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE ENGINEER.
UNLESS OTHERWISE INDICATED, SHOP DRAWINGS SHALL BE PROVIDED ON THE FOLLOWING:
a. CONCRETE MIX DESIGNS.
b. ALL REINFORCING STEEL.
DIVISION 2 - SITE WORK
A. GENERAL
1. REMOVE ALL ORGANIC MATERIAL AND TOPSOIL FROM AREAS UNDER THE BUILDING OR UNDER
PAVED AREAS.
2. FILL MATERIAL TO CONSIST OF A GRANULAR MATERIAL OR CONDITIONED SITE MATERIAL. PLACE FILL IN LIFTS NOT TO EXCEED 8 INCHES AND COMPACT TO 95% STANDARD ASTM D-1557 UNDER
FOOTINGS, UNDER PAVED AREAS AND UNDER FLOOR SLABS.
3. BASE MATERIAL IMMEDIATELY UNDER SLAB TO BE 6 INCH LAYER OF COMPACTED CRUSHED ROCK
WITH LESS THAN 5% PASSING THE #200 SIEVE.
4. DESIGN SOIL PRESSURE 1,500 (DL + LL), (PER IBC 1806.2).
5. ALL FOOTINGS TO BEAR A MINIMUM 18 INCHES BELOW FINAL GRADE ON FIRM, UNDISTURBED SOIL
OR APPROVED COMPACTED FILL. NOTIFY ENGINEER BEFORE PROCEEDING IF ANY UNUSUAL
CONDITIONS ARE ENCOUNTERED IN THE FOOTING EXCAVATIONS.
6. DO NOT EXCAVATE CLOSER THAN 2:1 SLOPE BELOW FOOTING EXCAVATIONS.
7. CLEAN ALL FOOTING EXCAVATIONS OF LOOSE MATERIAL.
8. EXCAVATIONS MAY BE MADE UNDER CONTINUOUS FOOTINGS FOR PIPES. BACKFILL TO BE
APPROVED BY GEOTECHNICAL ENGINEER.
B. REINFORCING
1. ALL REINFORCING TO BE ASTM A615 GRADE 60 UNLESS OTHERWISE NOTED.
2. USE ONLY A706 WELDABLE REBAR IF REBAR IS TO BE WELDED. USE ONLY LOW HYDROGEN
ELECTRODES. ALL WELDING TO BE IN COMPLIANCE WITH AWS D1.4.
3. FABRICATE AND INSTALL REINFORCING STEEL ACCORDING TO THE MANUAL OF STANDARD
PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES - ACI STANDARD 315.
DIVISION 4 - MASONRY - NOT USED
DIVISION 3 - CONCRETE AND REINFORCING
A. CONCRETE MIX/MATERIAL
1. STRENGTH: AVERAGE 28 DAY CONCRETE STRENGTH DETERMINED BY JOB CAST LAB CURED
CYLINDER TO BE AS INDICATED BELOW PLUS INCREASE DEPENDING ON THE PLANT'S STANDARD
DEVIATION AS SPECIFIED IN ACI 318. PROVIDE MIX DESIGNS TO THE ENGINEER FOR ALL
CONCRETE TO BE USED. CLEARLY LABEL ALL MIX DESIGNS FOR PROPOSED AREA OF USE.
2. MINIMUM MIX REQUIREMENTS:
LOCATION MIN. COMP. SLUMP MIN. CEMENT ADMIXTURES
STRENGTH (a) CONTENT
FOOTINGS AND STEMWALLS 3,000 PSI 0"-5" 470 LB NONE
CONCRETE RAMP 3,000 PSI 2"-4" 517 LB (b), (c) MISCELLANEOUS 3,000 PSI 0"-5" 470 LB (b)
(a) - SLUMP EXCEEDING SPECIFIED LIMITS SHALL NOT BE INCORPORATED IN THE PROJECT
EXCEPT BY WRITTEN APPROVAL FROM ENGINEER.
(b) - WRA = WATER REDUCING AGENT.
(c) - AE = AIR ENTRAINMENT.
(d) - UP TO 1 1/2 PERCENT CALCIUM CHLORIDE ALLOWED DURING COLD WEATHER.
(e) - POZZUTEC 20 REQUIRED FOR CONCRETE PLACED BELOW 40 DEGREES FAHRENHEIT.
3. USE TYPE I CEMENT, PER ASTM C-150 UNLESS OTHERWISE APPROVED.
4. AGGREGATES PER ASTM C33. USE 3/4 INCH MINUS UNLESS OTHERWISE NOTED OR APPROVED.
5. WATER REDUCING AGENT (WRA) SHALL BE POLYHEED 900 OR DARACEM 55 (MINIMUM 6 OZ. PER
100 POUNDS CEMENT). COMPLY WITH ASTM C-494.
6. AIR ENTRAINMENT (AE) SHALL COMPLY WITH ASTM C-260 AND SHALL BE USED ONLY WHERE
SPECIFIED AND/OR APPROVED BY ENGINEER.
7. ACCELERATORS: POZZUTEC 20+ NON-CHLORIDE FOR COMPONENTS EXPOSED TO WEATHER IN
THE COMPLETED STRUCTURE (WALLS, EXTERIOR PAVING, ETC.), CALCIUM CHLORIDE IN THE
INTERIOR SLABS ON GRADE. QUANTITY (DOSAGE) TO BE DETERMINED BY CONTRACTOR AND
APPROVAL OBTAINED FROM ENGINEER BEFORE USE OF ACCELERATORS.
8. PLACE AND CURE ALL CONCRETE PER ACI CODES AND STANDARDS.
9. SLEEVES, PIPES OR CONDUITS OF ALUMINUM SHALL NOT BE EMBEDDED IN STRUCTURAL
CONCRETE UNLESS EFFECTIVELY COATED.
DIVISION 5 - METAL
A. GENERAL
1. ALL STRUCTURAL MEMBERS TO BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE
WITH THE LATEST EDITION OF AISC STANDARDS.
B. MATERIALS
1. ANCHOR BOLTS AND WOOD CONNECTIONS TO BE A307. PROVIDE STANDARD PLATE WASHERS
UNDER ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD.
2. ANCHOR RODS TO BE ASTM F1554, GRADE 36 UNLESS OTHERWISE NOTED.
3. LAG BOLTS IN WOOD TO BE SAE J429 GRADE 1 WITH MINIMUM DIMENSIONS MEETING ANSI/ASME B.18.2.1.
C. POST-INSTALLED ANCHOR BOLTS:
1. UNLESS A SPECIFIC ANCHOR PRODUCT IS NOTED IN THE DRAWINGS, POST-INSTALLED
ANCHORS MAY USE ONE OF THE ANCHORS LISTED BELOW FOR THE REQUIRED TYPE AND BASE
MATERIAL. OTHER ANCHORS ARE ACCEPTABLE ONLY WITH PRIOR WRITTEN APPROVAL OF THE
ENGINEER.
2. INSTALL ALL ANCHORS PER MANUFACTURER'S INSTRUCTIONS AND PRODUCT EVALUATION
REPORTS.
3. EMBEDMENT SPECIFIED ON DRAWINGS FOR ADHESIVE ANCHORS ARE ‘EFFECTIVE’ EMBEDMENT.
‘NOMINAL’ EMBEDMENT IS SPECIFIED FOR EXPANSION AND SCREW ANCHORS, UNLESS
OTHERWISE NOTED. REFERENCE MANUFACTURER LITERATURE FOR MEASURING TOTAL
EMBEDMENT AND HOLE DEPTH REQUIREMENTS.
4. NOTE THAT ADHESIVE ANCHOR INSTALLATION TEMPERATURES AND CURE TIMES VARY BY
PRODUCT. CONSULT MANUFACTURER LITERATURE FOR SPECIFIC REQUIREMENTS.
5. ALL EXPANSION AND SCREW ANCHORS SPECIFIED AT EXTERIOR LOCATIONS OR EXPOSED TO
THE ELEMENTS SHALL BE THE STAINLESS STEEL VERSION PER EACH APPROVED
MANUFACTURER. EPOXY ANCHORS SPECIFIED AT EXTERIOR LOCATIONS OR EXPOSED TO THE
ELEMENTS SHALL USE STAINLESS STEEL OR HOT DIPPED GALVANIZED THREADED ROD.
6. SPECIAL INSPECTION OF ANCHOR INSTALLATION IS REQUIRED UNLESS SPECIFICALLY NOTED
OTHERWISE IN DRAWINGS. SEE SPECIAL INSPECTION AND MATERIALS TESTING PROGRAM AND
NOTES.
7. NO STEEL REINFORCEMENT SHALL BE CUT TO INSTALL ANCHORS WITHOUT THE PRIOR WRITTEN
APPROVAL OF THE ENGINEER.
8. ADHESIVE ANCHORS:
BASE MATERIAL PRODUCT REPORT#
CONCRETE SIMPSON SET-3G EPOXY ADHESIVE ANCHOR ICC ESR-4057
CONCRETE SIMPSON AT-3G ADHESIVE ANCHOR ICC ESR-5026
CONCRETE HILTI HIT-HY 200 V3 ADHESIVE ANCHOR ICC ESR-4868
9. EXPANSION ANCHORS:
BASE MATERIAL PRODUCT REPORT#
CONCRETE SIMPSON STRONG-BOLT 2 WEDGE ANCHOR ICC ESR-3037
CONCRETE HILTI KWIK BOLT TZ2 ANCHOR ICC ESR-4266
10. SCREW ANCHORS:
BASE MATERIAL PRODUCT REPORT#
CONCRETE SIMPSON TITEN HD SCREW ANCHOR ICC ESR-2713
CONCRETE HILTI KWIK HUS-EZ SCREW ANCHOR ICC ESR-3027
2. PROVIDE FIRE BLOCKING AS REQUIRED AND BLOCKING FOR ALL SPECIFIED WALL-MOUNTED ITEMS
INCLUDING CABINETS, DOORSTOPS, ETC.
3. CONNECTORS:
a. TIE STRAPS, FRAMING ANCHORS, HANGERS, STIRRUPS, COLUMN CAPS, COLUMN BASES, ETC., TO BE SIMPSON AS DETAILED, OR AS APPROVED.
b. FULLY FASTEN ACCORDING TO MANUFACTURER'S SCHEDULE USING LARGEST SIZE SHOWN.
c. ALL BEAMS AND JOISTS NOT BEARING ON ANOTHER MEMBER TO CONNECT WITH 'U' TYPE
HANGERS UNLESS OTHERWISE NOTED ON DRAWINGS.
d. NAILING: ALL NAILS SPECIFIED IN THE DRAWINGS TO BE "COMMON" NAILS UNLESS OTHERWISE
NOTED. ALL NAILING SHALL COMPLY WITH IBC FASTENING SCHEDULE PER CHAPTER 23.
OBTAIN ENGINEERS APPROVAL OF ALL PROPRIETARY NAILING SYSTEMS.
e. NAILS AT ROOF, FLOOR, AND WALL DIAPHRAGMS TO BE DRIVEN SO THAT THEIR HEAD OR
CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. CHECK AND RESINK IF NEEDED,
IMMEDIATELY BEFORE ROOFING.
f. BOLTS - SEE DIVISION 5, METAL.
g. CORROSION PROTECTION:
1. CONFIRM REQUIRED CORROSION PROTECTION FOR HARDWARE AND FASTENERS WITH
SPECIFIC RECOMMENDATIONS FROM PRESSURE TREATING MANUFACTURER OR HANGER
MANUFACTURER (USE MOST CONSERVATIVE) FOR SPECIFIC WOOD TREATMENTS USED.
2. MINIMUM CORROSION PROTECTION ON METAL CONNECTORS EXPOSED TO THE
ENVIRONMENT OR PRESSURE TREATED LUMBER TO BE PER ASTM A653 CLASS 185
(SIMPSON ZMAX) OR ASTM A123.
3. FASTENERS FOR PRESSURE TREATED LUMBER MUST BE MINIMUM HOT-DIP GALVANIZED,
STAINLESS STEEL, SILICON BRONZE OR COPPER.
4. HOT-DIP GALVANIZED HARDWARE AND FASTENERS MUST COMPLY WITH ASTM A153,
STAINLESS STEEL FASTENERS TO BE TYPE 304 OR TYPE 316.
5. HARDWARE AND FASTENERS USED TOGETHER MUST BE THE SAME TYPE (E.G. HOT-DIP
GALVANIZED NAILS WITH HOT-DIP GALVANIZED HANGERS).
4. DELIVERY AND STORAGE: ALL LUMBER AND SHEATHING DELIVERED TO THE SITE, SHALL BE
STACKED OR STORED OFF THE GROUND AND PROPERLY PROTECTED AGAINST WEATHER.
5. CUTTING AND NOTCHING OF JOISTS NOT ALLOWED. A 1 INCH DIAMETER HOLE MAY BE DRILLED IN
THE CENTER 1/3 OF THE MEMBER DEPTH. ALL OTHER HOLES TO BE APPROVED BY ENGINEER.
6. STUDS MAY BE NOTCHED IN THE LOWER 1/5 OF THE HEIGHT OF THE STUD FOR ELECTRIC AND PLUMBING PIPES, BUT NO PART OF THE NOTCH IS TO BE DEEPER THAN 25 PERCENT OF THE WIDTH OF THE STUD. HOLES OF DIAMETERS UP TO 1/3 OF WIDTH OF STUD MAY BE DRILLED IN THE STUD.
DIVISION 6 - WOOD
A. ROUGH CARPENTRY
1. LUMBER SPECIES AND GRADES TO BE AS FOLLOWS UNLESS OTHERWISE SHOWN ON DRAWINGS:
JOISTS, BEAMS & STRINGERS: DOUGLAS FIR #2
6 INCH NOMINAL AND GREATER: DOUGLAS FIR #1
BUCKS, BLOCKING, BRIDGING AND MISCELLANEOUS: DOUGLAS FIR OR HEM FIR #3
2x STUDS: DOUGLAS FIR #2
SILLS, LEDGERS, STRIPPING, ETC. IN CONTACT PRESSURE TREATED HEM FIR #2
WITH CONCRETE, AND WOOD CURBS:
PLATES AND HEADERS: KILN DRIED DOUGLAS FIR #2
POSTS, COLUMNS (SAWN): DOUGLAS FIR #1
ROOF, FLOOR AND WALL SHEATHING:
APA RATED SHEATHING, EXPOSURE 1, CONFORMING TO APA PERFORMANCE STANDARD PS
1-95 AND EXCERPT NER-108. SEE DRAWINGS FOR REQUIRED THICKNESS OF SHEATHING
AND/OR SPAN RATING. INSTALL ROOF AND FLOOR SHEATHING WITH LONG DIMENSION
PERPENDICULAR TO SUPPORTS UNLESS OTHERWISE NOTED. USE SPACERS TO PROVIDE 1/8
INCH END AND EDGE JOINTS WHENEVER SHEATHING IS EXPOSED TO WET WEATHER. FILL ANY
JOINT SPACING OVER 3/8 INCH UNLESS OTHERWISE APPROVED BY ENGINEER. INSTALL 2x4
OR THICKER BLOCKING AT UNSUPPORTED JOINTS IN WALL SHEATHING. BLOCK ROOF AND
FLOOR SHEATHING WHERE NOTED ON DRAWINGS.
GLULAM BEAMS:
• Fb = 2,400 PSI, E = 1,800,000 PSI PER ANSI A190.1 SPECIFICATION.
• SIMPLE SPANS COMBINATION: 24F-V4
• CANTILEVER SPANS COMBINATION: 24F-V8
• SUBMIT CERTIFICATE OF CONFORMANCE INDICATING MEMBERS MEET THE REQUIREMENTS
OF ANSI A190.1
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S0.0
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
ST
RU
C
TU
RA
L N O
TE
S
JJ
E
JJ
E
RJ
S
AJ
S
EXP. 12/31/2025
Justin Elliott
CODE REQUIRED SPECIAL INSPECTION AND MATERIALS TESTING PROGRAM
SOILS AND FOUNDATION SUBGRADE:
GRADING AND SUBGRADE COMPACTION
FOOTING EXCAVATION AND COMPACTION
CONCRETE:
VERIFY USE OF ENGINEER APPROVED CONCRETE MIX DESIGNS
FOOTING FORMWORK AND REINFORCING PLACEMENT
PRIOR TO AND DURING CONCRETE PLACEMENT FOR
CAST ANCHOR BOLTS AND EMBEDMENT PLATES
POST-INSTALLED ADHESIVE ANCHORS, RODS AND DOWELS IN
CONCRETE, PLACED HORIZONTALLY OR UPWARDLY INCLINED
POST-INSTALLED ADHESIVE ANCHORS, RODS AND DOWELS IN
CONCRETE, PLACED DOWNWARDLY INCLINED
POST-INSTALLED EXPANSION/WEDGE ANCHORS IN CONCRETE
POST-INSTALLED SCREW ANCHORS IN CONCRETE
WOOD:
ROOF-DIAPHRAGM SHEATHING AND NAIL SPACING
PRE-FABRICATED WOOD SHEAR PANEL CONNECTIONS
AND HOLDOWNS
SHEARWALL SHEATHING, NAIL SPACING AND HOLDOWNS
PRE-FABRICATED STRUCTURAL ELEMENTS
ARCHITECTURAL:
CEILING CLIPS
STRUCTURAL OBSERVATION
FOOTING REINFORCING
WOOD FRAMING PRIOR TO COVER
AT COMPLETION OF ROOF DIAPHRAGM NAILING
(INCLUDING WALL ANCHORAGE CONNECTIONS)
STRUCTURAL OBSERVATION NOTES:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE ENGINEER OF RECORD A MINIMUM OF 24 HOURS IN ADVANCED OF REQUIRED OBSERVATION(S). APPROVAL BY THE MUNICIPAL INSPECTOR DOES NOT PRECLUDE OBSERVATION BY THE ENGINEER OF RECORD AND APPROVAL BY THE ENGINEER OF RECORD DOES NOT PRECLUDE THE INSPECTION PROCESS BY THE MUNICIPAL INSPECTOR AND ANY OTHER CODE REQUIREMENTS FOR INSPECTION.
2. UPON COMPLETION OF WORK THE STRUCTURAL OBSERVER SHALL SUBMIT A REPORT TO OWNER AND BUILDING OFFICIAL WITH WET STAMP AND SIGNATURE ATTESTING TO THE VISUAL OBSERVATIONS MADE. THE REPORT SHALL IDENTIFY ANY
REPORTED DEFICIENCIES WHICH HAVE NOT BEEN RESOLVED.
COMMENTS
REF. PROJECT SPECIFICATIONS
DURATION INSPECTION AGENCY
P
C
C
P
P
P
P
P
P
P
P
P
P
P
P
P
P
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
TESTING LAB
ENGINEER
ENGINEER
ENGINEER
PER ICC EVALUATION REPORT
SEE NOTE 4, ITEM B
PER ICC EVALUATION REPORT
SEE NOTE 4, ITEM B
PER ICC EVALUATION REPORT
SEE NOTE 4, ITEM B
PER ICC EVALUATION REPORT
SEE NOTE 4, ITEM B
PER ICC EVALUATION REPORT
1. DURATION REFERS TO TIME AND FREQUENCY OF INSPECTION FOR THE PORTIONS OF WORK INDICATED.
C = CONTINUOUS INSPECTION IN WHICH THE SPECIAL INSPECTOR IS ON SITE AT ALL TIMES, OBSERVING THE WORK
REQUIRING SPECIAL INSPECTION.
P = PERIODIC INSPECTION IN WHICH THE SPECIAL INSPECTOR IS ON SITE AT TIME INTERVALS NECESSARY TO CONFIRM
THAT THE WORK REQUIRING SPECIAL INSPECTION IS IN CONFORMANCE WITH APPROVED PERMIT DRAWINGS AND
SPECIFICATIONS.
2. THE INSPECTION AGENCIES ARE AS FOLLOWS:
TESTING LAB: TO BE DETERMINED
TESTING LAB SHALL PERFORM INSPECTIONS OF ALL PORTIONS OF WORK DESIGNATED IN THE PROGRAM. THE SELECTED INSPECTION AGENCY SHALL BE AN ACCREDITED, APPROVED SPECIAL INSPECTION AGENCY EMPLOYED BY THE PROJECT
MANAGER, NOT THE CONTRACTOR OR SUB CONTRACTOR, PER IBC SECTION 1704.2.
3. DUTIES OF THE CONTRACTOR INCLUDE, BUT ARE NOT LIMITED TO:
A. NOTIFY THE SPECIAL INSPECTOR THAT THE WORK IS READY FOR INSPECTION AT LEAST 24 HOURS BEFORE SUCH
INSPECTION.
B. ALL WORK REQUIRING SPECIAL INSPECTION SHALL REMAIN ACCESSIBLE AND EXPOSED UNTIL IT HAS BEEN OBSERVED
AND INDICATED TO BE IN CONFORMANCE BY THE SPECIAL INSPECTOR AND APPROVED BY THE BUILDING OFFICIAL.
C. PROVIDE THE SPECIAL INSPECTOR WITH ACCESS TO APPROVED PERMIT DRAWINGS AND SPECIFICATIONS AT THE JOB
SITE.
D. MAINTAIN AT THE JOB SITE, COPIES OF ALL REPORTS SUBMITTED BY THE SPECIAL INSPECTOR.
4. IN ADDITION TO THE INSPECTION AND TESTING REQUIREMENTS INDICATED IN THE IBC, THE FOLLOWING SHALL ALSO APPLY:
A. CONCRETE INSPECTION AND TESTING REQUIREMENTS ARE AS FOLLOWS:
1. OBTAIN (4) TEST CYLINDERS FOR EACH 100 CUBIC YARDS PLACED (OR PORTION THEREOF IF LESS THAN 100 CUBIC YARDS ARE PLACED). BREAK (1) CYLINDER AT 7 DAYS AND (2) CYLINDERS AT 28 DAYS. (IF THE FIRST 28 DAY CYLINDER BREAK IS LESS THAN REQUIRED STRENGTH, HOLD (2) CYLINDERS FOR 56 DAY BREAK) HOLD 4TH CYLINDER FOR 56 DAY BREAK. BREAK 4TH CYLINDER ONLY IF REQUIRED STRENGTH IS NOT MET WITH (2) CYLINDERS AT 28 DAYS
2. VERIFY THAT THE APPROVED MIX DESIGNS ARE BEING DELIVERED TO THE SITE. BATCH TICKETS SHOULD BE
CHECKED FOR ALL TRUCKS ENTERING THE SITE.
B. POST INSTALLED ANCHORS IN CONCRETE SHALL BE INSPECTED AS FOLLOWS:
1. PROVIDE 'CONTINUOUS' OR 'PERIODIC' INSPECTION AS INDICATED IN THE SPECIAL INSPECTION TABLE (THIS SHEET).
INSPECTIONS ARE TO BE IN ACCORDANCE WITH THE MANUFACTURER'S CURRENT PRODUCT EVALUATION REPORT
AND INSTALLATION INSTRUCTIONS.
2. A COPY OF THE EVALUATION REPORT AND INSTALLATION INSTRUCTIONS ARE TO BE MAINTAINED ON THE JOB SITE.
ICC EVALUATION REPORTS ARE AVAILABLE ONLINE AT WWW.ICC-ES.ORG, AND IAPMO EVALUATIONS REPORTS ARE
AVAILABLE AT WWW.IAPMOES.ORG.
3. WHERE PERIODIC INSPECTION IS ALLOWED:
• THE SPECIAL INSPECTOR MUST BE ON SITE INITIALLY DURING ANCHOR INSTALLATION TO VERIFY MATERIALS AND
PROCEDURES AS REQUIRED BY THE EVALUATION REPORT.
• SUBSEQUENT INSTALLATIONS OF THE SAME ANCHOR TYPE AND SIZE BY THE SAME CONSTRUCTION PERSONNEL
ARE PERMITTED TO BE PERIODICALLY INSPECTED.
• A NEW INITIAL INSPECTION SHALL BE MADE FOR ANY CHANGE IN PERSONNEL PERFORMING THE ANCHOR
INSTALLATION OR CHANGE IN THE ANCHOR PRODUCT BEING INSTALLED.
• FOR ONGOING INSTALLATIONS OVER AN EXTENDED PERIOD, THE SPECIAL INSPECTOR MUST MAKE REGULAR
INSPECTIONS TO CONFIRM CORRECT HANDLING AND INSTALLATION. IF DISCREPANCIES ARE NOTED, CONTINUOUS INSPECTION SHOULD BE PROVIDED FOR ALL SUBSEQUENT ANCHORS.
4. ADHESIVE ANCHORS IN CONCRETE SHALL ADDITIONALLY CONFORM TO THE FOLLOWING
• CONCRETE IS TO HAVE A MINIMUM AGE OF 21 DAYS AT THE TIME OF ANCHOR INSTALLATION.
• CONTINUOUS INSPECTION IS REQUIRED FOR ALL ADHESIVE ANCHORS INSTALLED IN A HORIZONTAL TO VERTICAL
OVERHEAD ORIENTATION.
• INSTALLATION OF ADHESIVE ANCHORS IN A HORIZONTAL TO VERTICAL OVERHEAD ORIENTATION ARE TO BE DONE
BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI
318-19, SECTION 26.7. (NOT REQUIRED IN OREGON).
• ADHESIVE ANCHORS INSTALLED IN A HORIZONTAL TO VERTICAL OVERHEAD ORIENTATION ARE TO UTILIZE A
PISTON PLUG OR RETAINING CAP IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
C. MOISTURE TESTS PRIOR TO INSULATION
SPECIAL INSPECTION PROGRAM NOTES:
APPROVED FABRICATORS:
CERTIFICATE OF COMPLIANCE MUST BE SUBMITTED TO THE
ARCHITECT OR ENGINEER OF RECORD FOR ALL OFF-SITE
FABRICATION SUCH AS STRUCTURAL STEEL AND GLU-LAMS
P TESTING LAB
TESTING LAB
TESTING LAB
REF. STRUCTURAL NOTES
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S0.1
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
SP
EC
IA
L
IN
SP
EC
TI
O N
JJ
E
JJ
E
RJ
S
RJ
S
1 2 3
C
B
A
12' - 10" 10' - 7 1/2" 8' - 11"
/2
/2
2' - 0"
NOTE:
ALL DIMENSIONS TO CENTERLINE OF BEAMS ABOVE
H D U
H D
U
D
TT2Z
D
TT2Z
3 3
8" CONCRETE STEM
WALL PER 3
S3.0
S3.0
S3.0
32' - 7 1/2"
25' - 10" 6' - 9 1/2" PER ARCH
TYP
TYP
S3.0
USE SIMPSON 'HB' TOP
FLANGE HANGER AT
FLOOR BEAM CONNECTION
S3.0
TYP
S3.0
USE SIMPSON 'HUC' CONCEALED
FACE MOUNT HANGER AT FLOOR
BEAM CONNECTION
FOOTING AT BOTTOM OF DECK
STAIRS PER FLOOR FRAMING PLAN
CONCRETE FOOTING PER SCHEDULE THIS SHEET
FOUNDATION LEGEND:
H D
U X
SIMPSON HOLDOWN PER PLAN
FLOOR BEAM PER
B
S1.0
1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ELEVATIONS WITH
ARCHITECTURAL DRAWINGS.
2. CONTRACTOR TO VERIFY ALL FOOTING ELEVATIONS WITH THE
FOLLOWING CRITERIA: TOP OF FOOTING TO BE MINIMUM 12"
BELOW FINISH GRADE AND FINISH FLOOR. BOTTOM OF FOOTING
TO BE A MINIMUM OF 18" BELOW FINISH GRADE.
FOUNDATION NOTES:
1 2 3
C
B
A 6x12 6x12 6x12
6x12
6x126x12 x x
6x126x126x12 x x x x
2x10 AT 24" O.C.
(TYPICAL U.O.N.)
x x x
H D U
H D
U
D
TT2Z
D
TT2Z
A
A
B
A
(3) 2x6
JA
M
B S
TU
D S
(3) 2x6
JA
M
B S
TU
D S
(3) 2x4
JA
M
B S
TU
D S
(3) 2x4
JA
M
B S
TU
D S
(3) 2x6
JA
M
B S
TU
D S
(3) 2x6
JA
M
B S
TU
D S
S3.0
S3.0
S3.0
S3.0
A
32' - 7 1/2"
25' - 10" 6' - 9 1/2"
S3.0
TYP
S3.0
TYP
S3.0
ABOVE
TYP
S3.0
TYP
S3.0
GUARDRAIL POST PER ARCH
POST AND
FOOTING
AT BOTTOM OF STAIRS, PROVIDE
12" WIDE x 12" DEEP x CONTINUOUS FOOTING WITH (2) #4xCONT BARS
TOP AND BOTTOM
(SEE NOTE 12)
(SEE NOTE 12)
(SEE NOTE 12)
(S E
N O
T E
(S E
E N
O T
E
2x6 DOUG FIR #2 STUDS AT 16" O.C. TYPICAL, U.O.N.
ON PLAN. ALIGN JOISTS WITH STUDS
FOOTING BELOW PER FOUNDATION PLAN
FLOOR FRAMING LEGEND:
6x6 DF#1 POST
X
SHEAR WALL TYPE PER SCHEDULE THIS SHEET. ALL
EXTERIOR WALLS TO BE TYPE 'A' SHEAR WALLS
UNLESS OTHERWISE NOTED
FLOOR BEAM PER PLAN
2x4 DOUG FIR #2 STUDS AT 24" O.C.
FLOOR FRAMING NOTES:
1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ELEVATIONS
WITH ARCHITECTURAL DRAWINGS.
2. FLOOR DESIGN CRITERIA:
DEAD LOAD = 15 PSF
LIVE LOAD = 40 PSF
DEFLECTION = SMALLER OF LL/360, TL/240
3. FLOOR SHEATHING TO BE T&G APA RATED STURD-I-FLOOR
SHEATHING WITH A MINIMUM SPAN RATING OF 24" O.C. AND
MINIMUM THICKNESS OF 3/4". GLUE WITH CONTINUOUS WAVY
3/8" BEAD AT ALL SUPPORTS AND NAIL AS INDICATED BELOW.
ORIENT STRONG AXIS OF SHEATHING PERPENDICULAR TO
SUPPORTS.
4. FLOOR NAILING TO BE 10d RING OR SCREW SHANK NAILS WITH A
MINIMUM 1 5/8" PENETRATION. NAIL AT 6" O.C. AT ALL
SUPPORTED EDGES AND AT 12" O.C. AT INTERMEDIATE
SUPPORTS. BLOCKING IS NOT REQUIRED.
5. SPLICE DOUBLE TOP PLATE AT ALL EXTERIOR WALLS AND
SHEARWALLS BY LAPPING 6'-0" MINIMUM AND NAILING WITH 16d
AT 4" O.C. STAGGERED.
6. TYPICAL HEADERS (HDR) TO BE PER DETAIL , U.O.N.
7. AT BEAM TO POST CONNECTIONS USE SIMPSON 'AC' OR 'ACE'
POST CAP TYPICAL, U.O.N.
8. ALL SOLID SAWN HEADERS, PLATES (OTHER THAN P.T.) AND
HORIZONTAL MEMBERS TO BE KILN DRIED (K.D.) LUMBER.
9. ALL EXTERIOR WALLS TO BE SHEATHED PER SHEAR WALL TYPE
'A'. SEE SCHEDULE FOR REQUIREMENTS.
10. PROVIDE DOUBLE JOIST BELOW INTERIOR NON-BEARING WALLS
RUNNING PARALLEL WITH JOISTS.
11. SOLID BLOCK AT RIM LOCATIONS WHERE POSTS OR BUILT-UP
STUDS ARE BEARING.
12. ALL PORCH BEAMS TO BE RIPPED PER DETAIL
S2.0
S3.0
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S1.0
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
FO
U N D
AT
IO
N
FL
O O R
PL
AN
S
JJ
E
JJ
E
RJ
S
AJ
S
S1.0 1/4" = 1'-0"
A FOUNDATION PLAN
STRUCTURAL FOUNDATION SCHEDULE
MK BEAM FOOTING REINFORCING PIER SIZE NOTES
1 BEAM PER PLAN 2'-0" x 2'-0" x 12" DEEP (3) #4 EACH WAY BOTTOM 16" DIA. SEE DETAIL 2/S3.0
2 BEAM PER PLAN 2'-6" x 2'-6" x 12" DEEP (4) #4 EACH WAY BOTTOM 16" DIA. SEE DETAIL 1/S3.0
3 BEAM PER PLAN 3'-0" x 3'-0" x 12" DEEP (4) #4 EACH WAY BOTTOM 16" DIA. SEE DETAIL 1/S3.0
4 BEAM PER PLAN 3'-6" x 3'-6" x 12" DEEP (5) #4 EACH WAY BOTTOM 16" DIA. SEE DETAIL 1/S3.0
S1.0 1/4" = 1'-0"
B FLOOR FRAMING PLAN
1 2 3
C
B
A
2x10 AT 24" O.C.
(TYPICAL U.O.N.)
2x10 AT 24" O.C.
(TYPICAL U.O.N.)
6x10 x H
D R x x
6x10
5 1/8x13 1/2 GLB (RIDGE BEAM) 5 1/8x13 1/2 GLB (RIDGE BEAM) 5 1/8x13 1/2 GLB (RIDGE BEAM)
S3.1
S3.1
S3.1
6x6A B O
VE
H D R
4x6A B O
VE
H D R
6x6A B O
VE
H D R
6x
AB
O
VE
H
D R
S3.1
S3.1
OPP
S3.1
32' - 7 1/2"
25' - 10" 6' - 9 1/2"
HDR HDRHDR
HDR HDR
H D
R H
D R
H D
R x H
D R x H
D R x H
D R
TYP
TYP
TYP
STRUCTURAL BEARING WALL BELOW
ROOF FRAMING LEGEND:
WOOD POST PER FLOOR FRAMING PLAN
HEADER PER PLANHDR
NON-STRUCTURAL WALL BELOW
1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ELEVATIONS
WITH ARCHITECTURAL DRAWINGS.
2. ROOF DESIGN CRITERIA:
DEAD LOAD = 15 PSF
SNOW LOAD = 75 PSF + DRIFT
DEFLECTION = SMALLER OF LL/360, TL/240
3. ROOF SHEATHING TO BE APA RATED EXPOSURE I SHEATHING
WITH MINIMUM SPAN RATING OF 40/20 AND A MINIMIM
THICKNESS OF 19/32".
4. ROOF NAILING TO BE 10d COMMON OR GALVANIZED BOX
NAILS. NAIL AT 6" O.C. AT ALL SUPPORTED PANEL EDGES AND
AT 12" O.C. INTERMEDIATE SUPPORTS. BLOCKING IS NOT
REQUIRED.
5. SPLICE DOUBLE TOP PLATE AT ALL EXTERIOR WALLS AND
SHEARWALLS BY LAPPING 6'-0" MINIMUM AND NAILING WITH 16d
AT 4" O.C. STAGGERED.
6. TYPICAL HEADERS (HDR) TO BE PER DETAIL , U.O.N.
7. AT BEAM TO POST CONNECTIONS USE SIMPSON 'AC' OR 'ACE'
POST CAP TYPICAL, U.O.N.
WHERE POST IS BEARING ON BEAM, PROVIDED INVERTED
SIMPSON 'AC' OR 'ACE' POST CAP, TYPICAL
8. ALL SOLID SAWN HEADERS, PLATES (OTHER THAN P.T.) AND
HORIZONTAL MEMBERS TO BE KILN DRIED (K.D.) LUMBER.
9. ALL EXTERIOR WALLS TO BE SHEATHED PER SHEAR WALL
TYPE 'A'. SEE SCHEDULE FOR REQUIREMENTS.
10. INTERIOR BEARING WALLS WITHOUT A SCHEDULED SHEAR
ASSEMBLY TO BE PER DRAWINGS.
11. SOLID BLOCK AT RIM LOCATIONS WHERE POSTS OR BUILT-UP
STUDS ARE BEARING.
ROOF FRAMING NOTES:
S2.0
1 2 3
C
B
A
2x6 AT 16" O.C.
4x8 HDR 4x8 HDR
S3.1
S3.1
S3.1
S3.1
32' - 7 1/2"
25' - 10" 6' - 9 1/2"
1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ELEVATIONS
WITH ARCHITECTURAL DRAWINGS.
2. ROOF DESIGN CRITERIA:
DEAD LOAD = 10 PSF
LIVE LOAD = 10 PSF
DEFLECTION = SMALLER OF LL/360, TL/240
3. SOFFIT SHEATHING PER ARCH
4. SOFFIT NAILING TO BE 10d COMMON OR GALVANIZED BOX
NAILS. NAIL AT 6" O.C. AT ALL SUPPORTED PANEL EDGES AND
AT 12" O.C. INTERMEDIATE SUPPORTS. BLOCKING IS NOT
REQUIRED.
CEILING/SOFFIT FRAMING NOTES:
2x6 DOUG FIR #2 STUDS AT 16" O.C. TYPICAL U.O.N.
ON PLAN. ALIGN JOISTS WITH STUDS
CEILING/SOFFIT FRAMING LEGEND:
WOOD POST PER FLOOR FRAMING PLAN
NON-STRUCTURAL WALL BELOW
2x4 DOUG FIR #2 STUDS AT 24" O.C.
HEADER PER PLAN, SEE ALSO FLOOR FRAMING NOTESHDR
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S1.1
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
C
EI
LI
N G
RO
O F
FR
AM
IN
G
PL
AN
S
JJ
E
JJ
E
RJ
S
AJ
S
S1.1 1/4" = 1'-0"
B ROOF FRAMING PLAN
S1.1 1/4" = 1'-0"
A CEILING FRAMING PLAN
WOOD STUD SHEARWALL SCHEDULE - 10d NAILS
MARK SHEATHING AND NAILING SILL PLATE AND ANCHORAGE CAPACITY NOTES
UPPER WALL: 2x SOLE PLATE WITH 16d NAILS
AT 6" O.C. STAGGERED
FOUNDATION: 2x P.T. SILL PLATE WITH 5/8" DIA
LAG BOLTS AT 18" O.C.
435 PLF
(WIND)
310 PLF
(SEISMIC)
TYPICAL
EXTERIOR
WALLS
U.O.N.
UPPER WALL: 3x SOLE PLATE WITH SIMPSON SDS 1/4" x 6" AT 8" O.C.
FOUNDATION: 3x P.T. SILL PLATE WITH 5/8" DIA
LAG BOLTS AT 12" O.C.
WOOD STUD SHEARWALL SCHEDULE NOTES
A
B
15/32" APA RATED, EXPOSURE 1 SHEATHING,
ONE SIDE, ALL EDGES BLOCKED, WITH 10d
COMMON WIRE NAILS AT 6" O.C. ALL PANEL
EDGES AND 12" O.C. IN-FIELD
15/32" APA RATED, EXPOSURE 1 SHEATHING,
ONE SIDE, ALL EDGES BLOCKED, WITH 10d
COMMON WIRE NAILS AT 3" O.C. ALL PANEL
EDGES AND 12" O.C. IN-FIELD
1. INSTALL SHEATHING HORIZONTAL OR VERTICAL. NO PIECE SMALLER THAN 2'-0" x 2'-0".
2. ALL INTERIOR WALLS WITHOUT A SCHEDULE SHEAR ASSEMBLY TO BE SHEATHED PER ARCHITECTURAL DRAWINGS.
3. APPLY GYPSUM BOARD OVER SHEATHING AS REQUIRED BY ARCHITECTURAL DRAWINGS.
4. AT POSTS EMBEDDED IN SHEAR WALLS, ATTACH SHEATHING PER THE EDGE NAILING REQUIREMENTS FOR THAT SHEAR WALL.
5. ALL SHEAR WALL NAILS TO BE COMMON WIRE (10d = 0.148") OR GALVANIZED BOX NAILS (10d DIA = 0.128"). MINIMUM PENETRATION TO BE 1 3/8" FOR 8d NAILS. STAPLES ARE NOT AN ACCEPTABLE SUBSTITUTION.
6. ANCHOR BOLTS TO BE STANDARD LAG BOLTS WITH 5" MINIMUM EMBED AND 1 1/2" MINIMUM EDGE DISTANCE. PROVIDE A
MINIMUM OF (2) LAG BOLTS PER WALL SECTION.
7. PROVIDE PLATE WASHERS - MINIMUM OF 1/4" x 3" x 3" IN SIZE, AT ALL SILL PLATE ANCHOR BOLTS.
8. DO NOT USE NAILS FOR ANCHORAGE OF 3x SILL/SOLE PLATES. PROVIDE SIMPSON 'SDS' SCREWS AS SPECIFIED.
9. WHERE SHEAR WALL CAPACITY IS GREATER THAN 350 PLF, PANEL EDGE FRAMING RECEIVING EDGE NAILING FROM ABUTTING PANELS TO BE 3x NOMINAL FRAMING. PLYWOOD JOINT AND SILL PLATE NAILING TO BE STAGGERED IN ALL CASES.
840 PLF
(WIND)
600 PLF
(SEISMIC)
V E
R
IF
Y
F
IE
L D
O P
E N
IN
G
H E
IG
H
T
V E
R
IF
Y
F
IE
L D
HEADER PER PLAN
SIMPSON 'CS20' x 2'-0"
LONG COILED STRAP,
TYPICAL TOP AND
BOTTOM OF OPENING,
TYPICAL
POST PER FLOOR
FRAMING NOTES,
TYPICAL
2x6 DF#2 EACH END OF HDR WITH (4) 16d NAILS INTO HDR
END, SISTER STUDS TOGETHER
PER DETAIL
2x BLOCKING
AS REQ'D,
TYPICAL
OPENING WIDTH
EQ EQ
S2.0
A
C
B C
B E
A D
1' - 4" TYP.
1' - 0" MAX
1. 2x6 EXTERIOR STUDS: #2 & BTR AT 16" O.C.
2. 2x4 INTERIOR STUDS: #2 & BTR AT 16" O.C.
3. R-21 WALL INSULATION
4. DOUBLE TOP PLATE THROUGHOUT
5. 7/16" OSB WALL SHEATHING PER SHEARWALL
SCHEDULE
6. HARDI-PLANK LAP SIDING, ACCENT SIDING AT
GABLE ENDS PER ELEVATIONS
7. 2x8 PRE-PRIMED SPRUCED FASCIA
WALL FRAMING NOTES
A. HEADER PER SCHEDULE
B. TRIMMERS PER SCHEDULE
C. KING STUDS PER SCHEDULE
D. (2) A35 AT MULTIPLE KING STUDS
E. BLOCKING AT 7'-0" O.C. AND PER
SHEARWALL SCHEDULE
F. BLOCK SOLID AT MULTIPLE STUDS AND
CONTINUE MULTIPLE STUD GROUPS TO
FOUNDATION, UNO
KEYNOTE LEGEND#
2x4 BEARING WALL OPENING SCHEDULE
OPENING SIZE
UP TO 4'-0"
4'-0" TO 6'-0"
6'-0" TO 8'-0"
8'-0" TO 10'-0"
BEAM SIZE (A)
4x4 4x6 4x8 4x10
TRIMMERS (B)
(1)2x4 (1)2x4 (1)2x4 (2)2x4
KING STUDS (C)
(1)2x4 (1)2x4 (1)2x4 (2)2x4
2x6 BEARING WALL OPENING SCHEDULE
OPENING SIZE
UP TO 4'-0"
4'-0" TO 6'-0"
6'-0" TO 8'-0"
8'-0" TO 10'-0"
BEAM SIZE (A)
4x4 4x6 4x8 4x10
TRIMMERS (B)
(1)2x6 (1)2x6 (1)2x6 (2)2x6
KING STUDS (C)
(1)2x6 (1)2x6 (1)2x6 (2)2x6
HOLDOWN NOTES:
SIMPSON SPECIFIED
FASTENERS
WOOD POST PER PLAN
SIMPSON HOLDOWN
PER SCHEDULE
P.T. SILL PLATE
PER SHEARWALL
SCHEDULE
PT EDGE BEAM PER
PLAN
LAG SCREW PER
SCHEDULE
POST THICKNESS
PER SCHEDULE
1. HOLDOWNS, MANUFACTURED BY SIMPSON STRONG TIE, INC. INSTALL PER
SIMPSON RECOMMENDATIONS.
2. SHEARWALL SHEATHING TO BE ATTACHED TO VERTICAL MEMBER WITH EDGE
NAILING REQUIREMENTS PER SHEARWALL SCHEDULE.
3. MULTIPLE STUDS TO BE ATTACHED TOGETHER WITH 16d NAILS AT 8" O.C.
STAGGERED. ANY POST WITH THICKNESS 5 1/2" AND GREATER TO BE A SOLID
MEMBER.
LAG BOLTHOLDOWN
MINIMUM
POST THICKNESS
SIMPSON HOLDOWN SCHEDULE
3"SIMPSON 'HDU2-SDS2.5' 5/8" DIA x REQ'D LEGTH
2, 3
CONCRETE PIER
PER PLAN
M
IN
3"SIMPSON 'DTT2Z' 1/2" DIA x REQ'D LEGTH
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S2.0
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
SH
EA
RW
AL
L
SC
H
ED
U
LE
AN
D D
ET
AI
LS
JJ
E
JJ
E
RJ
S
AJ
S
S2.0 1/2" = 1'-0"
1 TYPICAL SHEARWALL ELEVATION
S2.0 1/4" = 1'-0"
3 TYPICAL WALL FRAMING
S2.0 1" = 1'-0"
2 SHEARWALL HOLDOWN SCHEDULE
FLOOR SHEATHING
PER PLAN
JOISTS PER PLAN
BEAM PER PLAN
STUD WALL PER PLAN
SIMPSON 'LB210' TOP
FLANGE HANGER EACH END
OFFSET BEAM TO
FLUSH WITH
EXTERIOR FINISH
P E
N E
T R
A T
IO
N
M
IN
S C
R E
W
LAG SCREW PER
SHEARWALL
SCHEDULE
FLOOR SHEATHING
PER PLAN
BLOCKING AT 4'-0" O.C.
IN FIRST JOIST BAY
BEAM PER PLAN
STUD WALL PER
PLAN
SIMPSON 'HUS' FACE
MOUNT HANGER EACH END
OFFSET BEAM TO
FLUSH WITH
EXTERIOR FINISH
JOIST PER PLAN
P E
N E
T R
A T
IO
N
M
IN
S C
R E
W
LAG SCREW PER
SHEARWALL
SCHEDULE
0'-0"
GRADE
-1'-0"
T.O.F.
16" DIA CONCRETE PEIR
WITH (4) #5 VERTICAL
BARS WITH 4" HOOK
3" CLR
3" CLR
FOOTING SIZE AND
REINFORCING PER
SCHEDULE
ROUGHEN SURFACE
OR POUR MONOLITHIC
(3) #3 TIES AT TOP
BALANCE AT 12" O.C.
C L R
POST PER PLAN
3" COMPACTED CRUSHED
ROCK BELOW FOOTING
POST CAP PER DETAIL
S3.0
SIMPSON 'AC' OR 'LCE'
INVERTED POST CAP AS REQ'D
0'-0"
GRADE
-1'-0"
T.O.F.
SIMPSON COLUMN CAP PER
16" DIA CONCRETE PIER
WITH (4) #5 VERTICAL
BARS WITH 4" HOOK
3" CLR
3" CLR
FOOTING SIZE AND
REINFORCING PER
SCHEDULE
ROUGHEN SURFACE
OR POUR MONOLITHIC
(3) #3 TIES AT TOP
BALANCE AT 12" O.C.
C L R
A S
R E
Q 'D
PLAN VIEWS (AS OCCURS PER FOUNDATION PLANS)
A A
PROVIDE SIMPSON
'CCQM' POST CAP
PROVIDE SIMPSON
'ECCLQM' POST CAP
PROVIDE SIMPSON
'CCTQM' POST CAP
PROVIDE SIMPSON
'CCCQM' POST CAP
3" COMPACTED CRUSHED
ROCK BELOW FOOTING
CONCRETE RAMP PER PLAN,
SLOPE PER ARCH
#4 HORIZONTAL BARS AT 12" O.C.
M
IN
C L R
(2) #4 HORIZONTAL BARS AT
TOP AND BOTTOM
BACKFILL PER STRUCTRUAL NOTES
#4 SLAB DOWELS AT 24" O.C.
HOOK
1' - 6" MIN
MATCH
ADJACENT
FOOTINGS
LINE OF FOOTING BEYOND
NOTE:
CONTRACTOR TO BRACE
STEM WALL AS REQUIRED
FOR BACKFILL UNTIL
RAMP SLAB IS PRESENT
0'-0"
GRADE
-1'-0"
T.O.F.
3" CLR
3" CLR3
C L R
STUD WALL PER PLAN
BEAM PER PLAN
BEAM PER PLAN
2x DECKING
PROVIDE SOLID WOOD BLOCKING
AS REQUIRED AT STUD WALL
FOOTING SIZE AND
REINFORCING PER SCHEDULE
3" COMPACTED CRUSHED
ROCK BELOW FOOTING
POST CAP PER
DETAIL 1
S3.0
STUD WALL PER PLAN
2x DECKING
BEAM PER PLAN
JOISTS PER PLAN PORCH BEAM BEYOND, RIM AS
REQUIRED, SO THAT TOP OF
PORCH DECKING ALIGNS WITH
TOP OF FLOOR SHEATHING
AS REQ'D
PER ARCH
2x6 TOP RAIL. ROUTER
EXPOSED EDGES 1/2" AND
SAND SMOOTH
2x4 HORIZONTAL RAILS
WITH SIMPSON 'APLH24'
HANGERS EACH END
SIMPSON 'A34' EACH END
OF TOP AND BOTTOM RAIL
POSTS PER PLAN
PAINT AND FINISH RAILING
PER ARCH
2x6 BOTTOM RAIL
P E
R A
R C
H
2x2 VERTICAL PICKETS A 5" O.C.
WITH 2 1/2" STAINLESS STEEL
WOOD SCREW INTO TOP AND
BOTTOM RAIL
AS REQ'D
T.O.F.
FOOTING SIZE AND
REINFORCING PER SCHEDULE
POST PER PLAN
PROVIDE SIMPSON 'APW66Z'
WITH 1/2" DIA x 3" EMBED
SCREW ANCHOR
WOOD DECKING
BEAM PER PLAN
M
IN
M
IN
CONCRETE RAMP PER
PLAN, SLOPE PER ARCH
PIER REINFORCING PER DETAIL
STEM WALL REINFORCING PER DETAIL
POST CAP PER DETAIL
S3.0
S3.0
S3.0
CONCRETE STEM WALL PER PLAN
CONCRETE PIER
PER PLAN
AS REQ'D
T.O.F.
FOOTING SIZE AND REINFORCING
PER SCHEDULE
POST PER PLAN
PROVIDE SIMPSON 'APW66Z'
WITH 1/2" DIA x 3" EMBED
SCREW ANCHOR
WOOD DECKING
BEAM PER PLAN
M
IN
M
IN
SIMPSON 'HUC'
BEAM HANGER
CONCRETE RAMP PER
PLAN, SLOPE PER ARCH
#4 HORIZONTAL BARS AT 12" O.C.
CONTINUE WALL REINFORCING
THROUGH FOOTING
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S3.0
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
FO
U N D
AT
IO
N
AN
D
FR
AM
IN
G
D
ET
AI
LS
JJ
E
JJ
E
RJ
S
AJ
S
S3.0 1" = 1'-0"
6 FLOOR FRAMING DETAIL
S3.0 1" = 1'-0"
7 FLOOR FRAMING DETAIL
S3.0 1" = 1'-0"
2 PIER FOOTING AT POST
S3.0 1" = 1'-0"
1 PIER FOOTING AT BEAM
S3.0 1" = 1'-0"
3 RETAINING WALL SECTION
S3.0 1" = 1'-0"
8 FLOOR FRAMING DETAIL
S3.0 1" = 1'-0"
9 FLOOR FRAMING DETAIL
S3.0 1 1/2" = 1'-0"
10 WOOD RAILING DETAIL
S3.0 1" = 1'-0"
5 RETAINING WALL SECTION
S3.0 1" = 1'-0"
4 RETAINING WALL SECTION
EXP. 12/31/2025
P
NOTE:
COORDINATE VENTING
REQUIREMENTS WITH ARCHITECT
SAWN JOIST PER PLAN PROVIDE
'BIRDS MOUTH' CUT AT BEARING
PLATE DO NOT OVERCUT
SIMPSON 'H3' AT EACH JOIST,
TYPICAL
ROOF SHEATHING
PER PLAN
SIMPSON 'RBC' AT 48" O.C.
WHERE SHEAR WALLS OCCUR
SPACE AT 24" O.C.
2x SHEAR BLOCKING
WITH BOUNDARY NAILING
COORDINATE EAVE
EXTENSION AND FRAMING
WITH ARCHITECT
SHEARWALL SHEATHING PER
PLAN, EXTEND FULL HEIGHT
STUD WALL PER PLAN
ROOF FRAMING
PER PLAN, TYPICAL
ROOF SHEATHING
PER PLAN, TYPICAL
RIPPED BLOCKING
WITH EDGE NAILING
SIMPSON 'LSSJ210'
FACE MOUNT
HANGER, TYPICAL
BEAM PER PLAN
FINISHES PER
ARCHITECT, TYPICAL
SOFFIT JOIST PER
PLAN WITH SIMPSON
'LUS26' HANGER STUD WALL
PER PLAN
2x LEDGER WITH (2) 10d
NAILS AT EACH STUD
FINISHES PER ARCH
2x BLOCKING AT 4'-0" O.C.
WITH 'LUS26' HANGER
EACH END
STUD WALL
PER PLAN
2x LEDGER WITH (2) 10d
NAILS AT EACH STUD
FINISHES PER ARCH
BEAM PER PLAN
BEAM PER PLAN
POST PER PLAN
WITH SIMPSON
'APVT6' STRAP
EACH SIDE
POST PER PLAN WITH
SIMPSON 'APVT6' STRAP
EACH SIDE
JOIST PER DETAIL
BEAM PER PLAN WITH
SIMPSON 'APHH610' HANGER
POST PER PLAN
BEAM PER PLAN
SIMPSON 'APVL6'
EACH SIDE
SIMPSON 'APVT6'
JOIST PER DETAIL
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1032437551
A
D D
E N
D U
M
/1
/2
A J S
S3.1
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
FR
AM
IN
G
D
ET
AI
LS
JJ
E
JJ
E
RJ
S
AJ
S
S3.1 1" = 1'-0"
3 ROOF FRAMING DETAIL
S3.1 1" = 1'-0"
5 PENTHOUSE FRAMING DETAIL
S3.1 1" = 1'-0"
1 CEILING/SOFFIT JOIST PERPENDICULAR
S3.1 1" = 1'-0"
2 CEILING/SOFFIT JOIST PARALLEL
S3.1 1" = 1'-0"
6 EXTERIOR POST ELEVATION
S3.1 1" = 1'-0"
4 EXTERIOR POST ELEVATION
MISC. VALVES & COCKS
SHUTOFF VALVE
GLOBE VALVE
GATE VALVE OS&Y
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
WYE STRAINER
WYE STRAINER WITH BLOWDOWN
DRAIN VALVE
BALANCING VALVE
PRESSURE REDUCING VALVE
RELIEF VALVE
TWO-WAY CONTROL VALVE
DOUBLE CHECK VALVE ASSEMBLY (DCVA)
REDUCED PRESSURE BACKFLOW PREVENTER (RPBP)
THERMOMETER
PRESSURE GAUGE
PRESSURE-TEMPERATURE TEST PLUG
MANUAL AIR VENT
AUTOMATIC AIR VENT
FLOW SWITCH
TEMPERATURE SENSOR
SHOCK ARRESTOR
VACUUM BREAKER
SHUTOFF VALVE WITH TAMPER SWITCH
THRUST BLOCK
SOLENOID VALVE
S
S
S
V
T
F
AAV
MAV
CLEANOUT
FLOOR CLEANOUT
CLEANOUT TO GRADE
WALL CLEANOUT
AREA DRAIN
CATCH BASIN
FLOOR DRAIN
OVERFLOW ROOF DRAIN
ROOF DRAIN
TRENCH SHOWER DRAIN
TRENCH DRAIN
HOSE BIBB
GROUND HYDRANT
WALL BOX HYDRANT
FLOOR SINK
PLUMBING SPECIALITIES
SYMBOLS
A
E
B
X
K
R
F
ACCESS PANEL
POINT OF CONNECTION
EXISTING TO REMAIN
BELOW GRADE / FLOOR
REVISION NUMBER
NUMBERED NOTE
REMOVE EXISTING
CAP EXISTING / CAP FOR FUTURE
RELOCATE EXISTING
FUTURE
EQUIPMENT
XXX
TAG NUMBER
XX-XXX
XXX
EQUIPMENT PROVIDED
FIXTURE NUMBER
FIXTURE UNITS
FIXTURE TYPE
FIXTURES DETAIL CALLOUT
X
XX.XX
X
XX
RISER TAG
DETAIL NUMBER
SHEET NUMBER
SYSTEM TYPE
RISER NUMBER
MISC. FITTINGS & SYMBOLS
DIRECTION OF FLOW
DIRECTION OF SLOPE
PIPE SLEEVE
REDUCER
ANCHOR
ELBOW (90 DEGREE)
PIPING CONNECTIONS
TEE
JOINT OR COUPLING POINT
PIPE CONTINUATION
HEAT TRACE
FLEXIBLE HOSE CONNECTOR
TEE DOWN
TEE UP
ELBOW DOWN
ELBOW UP
RISER
PLUG OR BLIND FLANGE
CAP
FLANGED CONNECTION
UNION
ELBOW (45 DEGREE)
MC
MECHANICAL COUPLING
PLUMBING PIPING
G
W WASTE ABOVE GRADE
W WASTE BELOW GRADE
STORM DRAIN ABOVE GRADE
STORM DRAIN BELOW GRADE
DRAIN (CONDENSATE/INDIRECT)
VENT
COLD WATER
HOT WATER
RECIRCULATING HOT WATER
IRRIGATION
NON-POTABLE WATER
SD
SD
D
V
CW
HW
RHW
IRR
NPW
BY OTHERS
GENERAL NOTES:
A. THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY APPEAR ON THIS SHEET
THAT DO NOT APPEAR ON THE DRAWINGS.
UNIT NUMBER
FLOOR UNIT IS
LOCATED ON
EQUIPMENT TYPE
XX-XXX XXXX-XX-XXXXX
UNIT NUMBER
FLOOR UNIT IS
LOCATED ON
EQUIPMENT TYPE
STANDARD ABBREVIATIONS
AREA DRAINAD
AMERICANS WITH DISABILITIES ACTADA
ABOVE FINISHED FLOORAFF
ALTERNATIVEALT
APPROXIMATELYAPPROX
ARCHITECT, ARCHITECTURALARCH
ACCESS PANELAP
BELOW FINISHED FLOORBFF
BUILDINGBLDG
BOTTOM OF PIPEBOP
BOTTOM OF STRUCTUREBOS
BRITISH THERMAL UNITBTU
BRITISH THERMAL UNITS PER HOURBTUH
BUTTERFLY VALVEBTV
BALANCING VALVEBV
CATCH BASINCB
CUBIC FEET PER HOURCFH
CUBIC FEET PER MINUTECFM
CUBIC FEET PER SECONDCFS
CALCULATIONCALC
CENTERLINECL
CLEANOUTCO
CONNECT, CONNECTIONCONN
CONTINUED, CONTINUATIONCONT
CIRCULATING PUMPCP
CLEANOUT TO GRADECTG
CONCRETECONC
CHECK VALVECV
DRAINAGE FIXTURE UNITDFU
DIAMETERDIA
DRINKING FOUNTAINDF
DOWN (PENETRATES FLOOR)DN
DRAINDR
DRAIN VALVEDV
DRAWINGDWG
EXISTING(E), EXIST
ELECTRONICALLY COMMUTATED MOTORECM
EMERGENCY EYE WASHEEW
ELECTRIC, ELECTRICALELEC
ELEVATIONELEV
ENGINEERENGR
EFFICIENCYEFF
EQUALEQ
EQUIPMENTEQUIP
EMERGENCY SHOWERES
ELECTRIC WATER COOLEREWC
ELECTRIC WATER HEATEREWH
ENTERING WATER TEMPERATUREEWT
EXPANSION TANKET
EXTRACTOREX
EXPANSIONEXP
EXHAUST OR EXHAUST AIREXH
DEGREES FAHRENHEITF
FLOOR CLEANOUTFCO
FLOOR DRAIN (PLUMBING)FD
FIRE DEPARTMENT CONNECTIONFDC
FINISHED FLOOR ELEVATIONFFE
FIGUREFIG
FLOORFL
FULL LOAD AMPACITYFLA
FIRE PUMPFP
FEET PER MINUTEFPM
FEET PER SECONDFPS
FLEXIBLEFLEX
FLOOR SINKFS
FEET/FOOTFT
FIXTURE UNITFU
FLUSH VALVEFV
FUTURE(F)
GRADEG
FLUSH TANKFLT
GAGE/GAUGEGA
GALLONGAL
GALVANIZEDGALV
GLYCOLGLY
GALLONS PER HOURGPH
GALLONS PER MINUTEGPM
GATE VALVEGV
HEIGHTH
GROUND HYDRANTGH
HOSE BIBBHB
HUB DRAINHD
HORIZONTALHORIZ
HORSEPOWERHP
HEAT TRACEHT
HOURHR
INSIDE DIAMETER, INSIDE DIMENSIONID
MAXIMUMMAX
THOUSAND BTU PER HOURMBH
MINIMUM CIRCUIT AMPACITYMCA
MECHANICALMECH
MINIMUM EFFICIENCY REPORTING VALUEMERV
MANUFACTURERMFR
MISCELLANEOUSMISC
MAXIMUM OVERCURRENT PROTECTIONMOCP
MOP SINKMS
MOUNTEDMTD
MINIMUMMIN
NORMALLY CLOSEDNC
NOT IN CONTRACTNIC
NORMALLY OPENNO
NOMINAL PIPE SIZENPS
NOT TO SCALENTS
OVERFLOW DRAINOD
OUTSIDE SCREW & YOKE GATE VALVEOS&Y
PHASEPH
POST INDICATING VALVEPIV
POLYPROPYLENEPP
PRESSURE REDUCING VALVEPRV
PRESSURE GAUGEPG
PRESSURE SWITCHPS
POUNDS PER SQUARE INCHPSI
POUNDS PER SQUARE INCH (GAUGE)PSIG
POLYVINYL CHLORIDEPVC
RADIUSR, RAD
ROOF DRAINRD
REVISIONREV
REVOLUTIONS PER MINUTERPM
SINKS
STANDARD CUBIC FEET PER MINUTESCFM
SHOWER DRAIN (PLUMBING)SD
SMOKE DAMPER (MECHANICAL)SD
SEWAGE EJECTORSE
SQUARE FOOT, SQUARE FEETSF
SHOWERSH
SIMILARSIM
SECTIONSECT
SHUTOFF VALVESOV
SPECIFICATIONSPEC
SQUARESQ
STAINLESS STEEL (ALL)SS
SQUARE INCH, SQUARE INCHESSQ IN
TRENCH DRAINTD
TOTAL DEVELOPED LENGTHTDL
TEMPERATURETEMP
THERMOSTATIC MIXING VALVETMV
TOP OF PIPETOP
TOTAL DISCHARGE HEADTDH
TRAP PRIMER VALVETP
TAMPER SWITCHTS
TOTAL STATIC PRESSURETSP
TYPICALTYP
UNDERGROUNDUG
UP (PENETRATES FLOOR SLAB)UP
VOLTSV
URINALU
VACUUM BREAKERVB
VOLUME DAMPERVD
VELOCITYVEL
VERTICALVERT
VENT THROUGH ROOFVTR
WIDTHW
WATER CLOSETWC
VARIABLE FREQUENCY DRIVEVFD
WALL CLEANOUTWCO
WATER FIXTURE UNITSWFU
WATER GAUGEWG
WALL HYDRANTWH
WITHW/
WATER HAMMER ARRESTORWHA
WITHOUTW/O
LAVATORYLAV
POUNDLB
LINEAR FEETLF
KILOWATTKW
KILOWATT HOURKWH
ISOMETRICISO
LENGTHL
IRON PIPE SIZEIPS
INSULATIONINSUL
INVERT ELEVATIONIE
INCH, INCHESIN
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
1224936729
P0.01
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
PA
RK
D
EL
U
XE
C
AB
IN
SY
M
BO
LS
AN
D
LE
G
EN
D S
PL
U M
BI
N G
PA
E
PA
E
PA
E
PA
E
PLUMBING SHEET LIST
SHEET # SHEET NAME
P0.01 SYMBOLS AND LEGENDS - PLUMBING
P0.02 SCHEDULES - PLUMBING
P2.11 FLOOR PLAN - PLUMBING
P5.01 DETAILS - PLUMBING
Grand total: 4
L
R E
N
G
O
R
I
E
I
S
ST
S
E
E
N
ER
F
E
E
G
OD R
N
EXPIRES: 12/31/2024
P
A
I
82128PE
OREGON
M
A Y 2 2 , 2
15C
H A
RLES H. NOR
R
IS
10/17/24
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
P0.02
PA
E
PA
E
PA
E
PA
E
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
EL
U
XE
C
AB
IN
SC
H
ED
U
LE
S
PL
U M
BI
N G
36729 12249
SANITARY WASTE AND VENT SCHEDULE 40 SOLID WALL PVC: ASTM D2665-85a, ASTM D3311-82.
COPPER MANIFOLDS WITH INTEGRAL VALVES. PEX-A COLD EXPANSION TYPE FITTINGS, ASTM F1960.
NON-HEAT TRACE
CROSS-LINKED POLYETHYLENE (PEX): PEX-A OR PEROXIDE METHOD, ASTM F876, ASTM F877, CAN/CDA-B137.5.
ANSI B16.22 SOLDERED JOINTS.
DOMESTIC WATER
UNDER HEAT TRACE
COPPER: ASTM B88 HARD DRAWN COPPER TUBING, TYPE L, WROUGHT COPPER FITTINGS (150 PSI SERVICE), SERVICE MATERIAL
PIPE SCHEDULE
ALL WASTE PIPING SIZED AT 1/4"/FT. SLOPE UNLESS OTHERWISE NOTED.
BASIS OF DESIGN: 2023 OREGON PLUMBING SPECIALTY CODE, CHAPTER 7, 'SANITARY DRAINAGE'.
WASTE AND VENT PIPING SYSTEM:
AND NOT TO EXCEED 5 FT./SEC. (HOT WATER).
WATER SUPPLY SYSTEM'. PIPING SIZED ON 3 PSI/100 FT. DROP, VELOCITIES NOT TO EXCEED 8 FT./SEC. (COLD WATER)
BASIS OF DESIGN: 2023 OREGON PLUMBING SPECIALTY CODE, APPENDIX A 'RECOMMENDED RULES FOR SIZING THE
DOMESTIC WATER PIPING SYSTEM:
PLUMBING DESIGN CRITERIA (OREGON)
A. COORDINATE POWER SUPPLY WITH DIVISION 26
GENERAL NOTES:
EWH-101 ELECTRIC WATER HEATER DOMESTIC HOT WATER ELECTRIC TANK TYPE WATER HEATER 40 25 ELECTRIC 2 6 3 28.8 240/1 AO SMITH HNT-40
NUMBER DESCRIPTION SERVICE TYPE (GAL) (GAL/HR) TYPE ELEMENTS TOTAL kW ELEMENT FLA PHASE & MODEL NOTES
TAG CAPACITY @ 100F RISE NO. OF kW PER VOLT/ MANUFACTURER
STORAGE RECOVERY
ELECTRICAL
WATER HEATER SCHEDULE
WB-1 WALL BOX HYDRANT - - 3/4 - - - FREEZE PROOF, BOX/FLUSH TYPE w/LOCKING COVER, INTEGRAL VACUUM BREAKER
SH-1 SHOWER (2) 2 (2) 1-1/2 1/2 1/2 - 1.5 TILED ENCLOSURE, FIXED AND HAND HELD SHOWER HEADS, MIXING AND DIVERTER VALVES, LINEAR DRAIN AND SPOT DRAIN.
S-1 SINK 2 1-1/2 1/2 1/2 - 1.5 COUNTERTOP, STAINLESS STEEL, MANUAL SINGLE LEVER FAUCET
L-1 LAVATORY 2 1-1/2 1/2 1/2 - 0.5 WALL HUNG, MANUAL FAUCET, ADA
WC-1 WATER CLOSET 4 2 3/4 - - 1.28 FLOOR MOUNTED, TANK TYPE, ADA
NUMBER FIXTURE TYPE W V CW HW TW GPM/GPF DESCRIPTION NOTES
TAG ROUGH-IN SIZE (INCHES)
PLUMBING FIXTURE SCHEDULE
A
D D
E N
D U
M
/1
/2
P A
E
L
R E
N
G
O
R
I
E
I
S
ST
S
E
E
N
ER
F
E
E
G
OD R
N
EXPIRES: 12/31/2024
P
A
I
82128PE
OREGON
M
A Y 2 2 , 2
15C
H A
RLES H. NOR
R
IS
03/10/25
EXPIRES: 12/31/2026
SLEEPING
LIVING/DINING
BATHROOM
WC-1
SH-1
L-1
S-1
PEX DISTRIBUTION
MANIFOLDS
P5.01
3/4" CW DN
2" W DN
3" VTR
2" W DN
2" V DN
3" VTR
1 1/2" V DN
WB-1
B B
C C
A A
B 3/4" CW
EWH-101
1 1/2" V DN
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
P2.11
PA
E
PA
E
PA
E
PA
E
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
EL
U
XE
C
AB
IN
FL
O O R
PL
AN
U M
BI
N G
36729 12249
1/4" = 1'-0"
FLOOR PLAN - PLUMBING
A. RUN PIPING CONCEALED, UNLESS SPECIFIED
OTHERWISE, AND CLEAR OF CEILING
INSERTS. ALL PIPING SHALL BE INSTALLED AS
CLOSE AS POSSIBLE TO WALL AND
UNDERSIDE OF BEAMS AND JOISTS.
B. ALL WORK SHALL BE COORDINATED WITH ALL
TRADES INVOLVED. OFFETS IN PIPING AND
TRANSITIONS AROUND OBSTRUCTIONS SHALL
BE PROVIDED AT NO ADDITIONAL COST TO
THE OWNER.
C. VERIFY ALL EQUIPMENT CONNECTIONS WITH
MANUFACTURER'S CERTIFIED DRAWINGS.
FIELD VERIFY AND COORDINATE ALL
DIMENSIONS BEFORE FABRICATION.
D. PROVIDE FINAL CONNECTION TO ALL
PLUMBING FIXTURES.
E. COORDINATE ACCESS PANEL LOCATIONS
WITH ARCHITECT.
F. COORDINATE ALL UNDERGROUND PIPE
ROUTINGS WITH AVOID STRUCTURAL
FOOTING LOCATIONS AND DEPTHS TO AVOID
CONFLICTS.
GENERAL NOTES:
1. CABIN COLD WATER SUPPLY FROM SITE
WATER DISTRIBUTION SYSTEM. REFER TO
CIVIL FOR CONTINUATION.
2. CABIN SANITARY WASTE CONNECTION TO
SITE SEWER SYSTEM. REFER TO CIVIL FOR
CONTINUATION.
3. WASTE PIPING ROUTED UNDERFLOOR
TIGHT TO STRUCTURE INSIDE INSULATION
LAYER.
4. WASTE PIPE CLEANOUT UNDER FLOOR
ACCESSIBLE TO MAINTENANCE STAFF.
5. WASTE MAIN TO DROP OUT OF INSULATION
LAYER TO BELOW GRADE. PROVIDE CAST
IRON SLEEVE AROUND PLASTIC WASTE
PIPING TO PREVENT RODENT DAMAGE.
6. LINEAR SHOWER DRAIN AT SHOWER
THRESHOLD.
NOTES:
NORTH
A
D D
E N
D U
M
/1
/2
P A
E
L
R E
N
G
O
R
I
E
I
S
ST
S
E
E
N
ER
F
E
E
G
OD R
N
EXPIRES: 12/31/2024
P
A
I
82128PE
OREGON
M
A Y 2 2 , 2
15C
H A
RLES H. NOR
R
IS
RELIEF VALVE
THERMOMETER
ELECTRIC
WATER
HEATER
DRAIN PAN
1. 3/4" COLD WATER SUPPLY FROM SITE DISTRIBUTION.
2. WATER HEATER T&P RELIEF SPILLS INTO DRAIN PAN.
3. WATER SUPPLY SHUT OFF VALVE BOX. REFER TO VALVE
BOX DETAIL.
NOTES:1
PEX MANIFOLDS
PEX TUBING (TYP)
PEX TRANSITION (TYP)
CONNECTIONS TO MANIFOLD
3/4"
EWH-101
DRAIN VALVE
WATER HEATER STAND
SH-1
L-1
S-1
WC-1
SH-1
L-1
S-1
WB-1
GRADE
4. CAST IRON PIPE SLEEVE THROUGH CRAWL SPACE TO
PROTECT UTILITY PIPING FROM RODENT DAMAGE.
5. SEAL PIPE SLEEVE AT CABIN FLOOR.
6. HEAT TRACE ANY EXPOSED WATER PIPING BETWEEN
GRADE LEVEL AND CABIN FLOOR FOR FREEZE
PROTECTION. ROUTE WATER PIPE IN COPPER FOR THE
SECTION THAT HAS HEAT TRACE.
CABIN FLOOR
CRAWLSPACE
PEX ROUTING OVERHEAD
TO EACH FIXTURE (TYP)
MAX. 24"
SHUTOFF
VALVE
DRAIN
VALVE
1. PLASTIC COVER AND FRAME.
2. CROWN TO SHED WATER.
3. 36" LENGTH OF 12" DIAMETER VALVE BOX AND RISER.
4. WATER SUPPLY TO CABIN.
5. 3/4" MINUS GRAVEL FILL.
6. WATER SUPPLY AT DEPTH TO PROTECT FROM FREEZING.
NOTES:
1 2
5 6
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
P5.01
PA
E
PA
E
PA
E
PA
E
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
EL
U
XE
C
AB
IN
D
ET
AI
LS
PL
U M
BI
N G
36729 12249
NONE
1 WATER SYSTEM DETAIL
NONE
2 VALVE BOX DETAIL
A
D D
E N
D U
M
/1
/2
P A
E
L
R E
N
G
O
R
I
E
I
S
ST
S
E
E
N
ER
F
E
E
G
OD R
N
EXPIRES: 12/31/2024
P
A
I
82128PE
OREGON
M
A Y 2 2 , 2
15C
H A
RLES H. NOR
R
IS
HVAC PIPING
REFRIGERANT LIQUID
REFRIGERANT SUCTION
RL
RS
STANDARD ABBREVIATIONS GENERAL NOTES:
A. THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY APPEAR ON THIS SHEET
THAT DO NOT APPEAR ON THE DRAWINGS.
AIR PRSSURE DROPAPD
BACKDRAFT DAMPERBDD
BREAK HORESPOWERBHP
BRITISH THERMAL UNITBTU
BRITISH THERMAL UNITS PER HOURBTUH
CUBIC FEET PER MINUTECFM
ENTERING AIR TEMPERATUREEAT
FEET PER MINUTEFPM
FEET PER SECONDFPS
FEET/FOOTFT
OUTSIDE AIROSA
RELIEF AIRRA
SUPPLY AIRSA
VARIABLE FREQUENCY DRIVEVFD
LEAVING AIR TEMPLAT
UNIT NUMBER
EQUIPMENT TYPE
XX-XXX
EQUIPMENT
XXXX-XX-XXXXX
UNIT NUMBER
FLOOR UNIT IS
LOCATED ON
EQUIPMENT TYPE EQUIPMENT PROVIDED
BY OTHERS
XXX
TAG NUMBER
TU-X-XXX
DETAIL CALLOUT
X
XX.XX
DETAIL NUMBER
SHEET NUMBER
SYMBOLS
A
E
B
X
K
R
F
ACCESS PANEL
POINT OF CONNECTION
EXISTING TO REMAIN
BELOW GRADE / FLOOR
REVISION NUMBER
NUMBERED NOTE
REMOVE EXISTING
CAP EXISTING / CAP FOR FUTURE
RELOCATE EXISTING
FUTURE
WALL-MOUNTED
PENDENT-MOUNTED
TEMPERATURE
HUMIDITY
DIFFERENTIAL
PRESSURE SWITCH
T
H
DP
T
H
DP
WALL-MOUNTED
PENDENT-MOUNTED
CARBON MONOXIDE
CARBON DIOXIDE
NITROGEN OXIDE
CO
CO2
NOX
CO
CO2
NOX
SENSORS
TERMINAL UNIT NUMBER
TERMINAL UNIT
FLOOR UNIT IS LOCATED ON
AIR HANDLER NUMBER
TERMINAL UNITS
24x16
R
R=1-1/2W
RADIUS ELBOW
W
MITER ELBOWS & TEES
TURNING VANES IN ALL
ELBOWS AND TEES FLEX
CONNECTION ACOUSTICAL LINER
SIZE SHOWN IS CLEAR
AIR PASSAGE
DUCT OFFSETS
R=1-1/2W W
LESS THAN 15° 15° TO 30° GREATER THAN 30°
30° MAX 30° MAX
TRANSITIONS
RECTANGULAR TO ROUND
45°
W
4" MIN OR
1/4W OR
12" MAX
RECTANGULAR DUCT FITTING
SPIN-IN
FITTING
CONICAL SPIN-IN
FITTING
RECTANGULAR TO ROUND FITTING
FS
D
CFM
TYPE
RETURN EXHAUST SUPPLY
FLOW DIRECTION
(NONE SHOWN
IF 4-WAY)
CFM
SIZE TYPE
TYPE REFERENCE
H = 6" BELOW CEILING
L = 6" ABOVE FLOOR
F = FLOOR
S = SLOT DIFFUSER
C = CEILING
T = DOOR TRANSFER
NECK SIZE (SIDEWALL & FLOOR GRILLE)
PLENUM INLET SIZE (SLOT DIFFUSER)
CEILING DIFFUSERS & GRILLES SIDEWALL, SLOT & FLOOR GRILLES
SUPPLY
AIR
RETURN
AIR
EXHAUST
AIR
OUTSIDE
AIR
DUCT SECTIONS
COMBINATION
FIRE/SMOKE FIRE
SMOKE
VOLUME
AUTOMATIC
RETURN OR EXHAUST AIR FLOW
SUPPLY OR OUTSIDE AIR FLOW
UNDERCUT DOORUC 1/2"
SECTION
R=2D FOR FLEX
PLAN
R=1-1/2D FOR ROUNDD
R
RETURN OR EXHAUST GRILLE CONNECTION
SECTION
D
R
R=2D FOR FLEX
PLAN
R=1-1/2D FOR ROUNDD
R
SUPPLY DIFFUSER CONNECTION
SECTION PLAN
SECTION PLAN
SECTION PLAN
SUPPLY DIFFUSER SIDE FLEX CONNECTION
SECTION PLAN
RETURN OR EXHAUST GRILLE
FLEX DUCT ROUND DUCT
FLEX DUCT ROUND DUCT
RECTANGULAR DUCT SQUARE NECK
SPIN-IN
FITTING
D
R
LINED PLENUM
FLEX DUCT
SEE SPEC FOR TYPE
SEE SCHEDULE FOR SIZE
DAMPERS
SECTION PLAN SECTION PLAN
SUPPLY DIFFUSER HARD CONNECTION SIDEWALL SUPPLY GRILLE CONNECTION
DUCT LEGEND
LOW PRESSURE DUCTWORK
DUCT DETAILS (LOW VELOCITY)
FD S
D
INCH, INCHESIN
P A R K
SO
N
E G
O R S T A T E
O
RE
G O N
PA
RK
S
AN
D
RE
C
RE
AT
IO
N
D
EP
AR
TM
EN
T
D E S
IG
N E D
B Y
A P P R O V E D
B Y
C H E C K E D
B Y
D R A W N
B Y
D A
TE
R E V
IS
IO
N
D A
TE
B Y
SHEET:
OPRIS#: CONTRACT #:
M0.01
PA
E
PA
E
PA
E
PA
E
O
PR
D
PR
IN
EV
IL
LE
RE
SE
RV
O
IR
ST
AT
E
EL
U
XE
C
AB
IN
SY
M
BO
LS
LE
G
EN
D S
AN
D
SC
H
ED
U
LE
S
M
EC
H
AN
IC
AL
36729 12249
MECHANICAL SHEET LIST
SHEET # SHEET NAME
M0.01 SYMBOLS, LEGENDS AND SCHEDULES - MECHANICAL
M2.11 FLOOR PLAN - MECHANICAL
Grand total: 2
A
D D
E N
D U
M
/1
/2
P A
E
A. OUTDOOR CONDITIONS BASED ON ASHRAE FUNDAMENTALS 2021 99.6% AND 0.4% DATA.
GENERAL NOTES:
INDOOR 70˚ F ± 2˚ F DB 75˚ F ± 2˚ F DB
OUTDOOR 5˚ F DB 94˚ F DB / 61˚ F MCWB
TEMPERATURE TEMPERATURE
SPACE
WINTER SUMMER
DESIGN CONDITIONS…