Report_Abestos Containing Mat Survey_PR-3.pdf

PDF 3 MB Posted

Attached to
Signs and Safety Repairs Project in PR-1, PR-2, and PR-3
Solicitation number
693C73-21-B-000006
Issued by

About this file

This solicitation seeks sealed bids from certified small business concerns for a signs and safety repairs project along highways PR-1, PR-2, and PR-3 in Puerto Rico. The project consists of repairing signs and guardrails damaged by Hurricanes Irma and Maria, including traffic sign assemblies, new guardrails and end terminals, bridge transition upgrades, traffic sign and guardrail demolition and removal, and temporary traffic control. The total cost of the project is expected to exceed $10 million and will be split into multiple schedules. Bids are due on a date specified in block 13a of the solicitation. Interested vendors must register at beta.sam.gov to receive email notifications and access solicitation documents, which will no longer be mailed. Bidders must have valid representation and certifications on sam.gov and dol.gov. Questions should be directed to eflhd.contracts@dot.gov.

View the file

Other files

File Type Posted
Results of the Bid Opening - PR ST ER PRMNT RPR (6).pdf PDF
Amended Plan Sheets_Standard Drawings_Amendment 2.pdf PDF
Amendment 0002.pdf PDF
Bid Schedule_Amendment 2.pdf PDF
Plan Sheet Changes Summary_Amendment 2.pdf PDF
B Pages Changes Summary_Amendment 2.pdf PDF
Amendment 0001 - PR ST ER PRMNT RPR(6).pdf PDF
NEPA_OGPE_PR-1.pdf PDF
NEPA_PR-3_Part1 (Pages 1 - 115).pdf PDF
Plans_Sch A_PR-2 Unit 1.pdf PDF
Plans_Sch B_PR-3 Unit 1.pdf PDF
NEPA_PR-1_Archeological Monitoring.pdf PDF
PRHTAs Standard Drawings_RPR(6).pdf PDF
Plans_Sch B_PR-3 Unit 2.pdf PDF
NEPA_PR-3_Part3 (Pages 231 - 346).pdf PDF
Report_Lead Based Paint Survey_PR-3.pdf PDF
Report_Lead-Abestos_PR-2.pdf PDF
Plans_Sch A_PR-2 Unit 4.pdf PDF
NEPA_PR-1.pdf PDF
Certification _No Presence of Asbesto_PR3.pdf PDF
Plans_Sch B_PR-3 Unit 3.pdf PDF
PRHTAs Standard Specifications.pdf PDF
Plans_Sch C_PR-1.pdf PDF
Plans_Sch A_PR-2 Unit 2.pdf PDF
NEPA_PR-2.pdf PDF
Letter_Procedure to Deliver Salvageable Materials.pdf PDF
IFB Solicitation - PR ST ER PRMNT RPR (6).pdf PDF
Report_Abestos Containing Material Survey_PR-1.pdf PDF
ADV_Bidders Qualifications Form.doc DOC document
Report_Limited Lead Paint Survey_PR-1.pdf PDF
Plans_Sch A_PR-2 Unit 3.pdf PDF
DTOPs Manual de Senales de Transito (MST).pdf PDF
NEPA_PR-3_Part2 (Pages 116 - 230).pdf PDF
VETS-4212 Form.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ACM SURVEY

FOR

GUARDRAILS ALONG PR3 FROM KM 0.0 IN SAN JUAN

TO KM 159.15 IN SALINAS

Prepared For:

Puerto Rico Highway and Transportation Authority

October 2019

Prepared By:

Analytical Environmental

Services International, Inc.

611 Monserrate Street

2nd Floor, Santurce, P.R. 00907

(787) 722-0220 / Fax (787) 724-5788

(EXCEPT 46.60 TO 48.90)

Rev. 11/5/19

General View of PR3 Guardrails Project from Km 0 to 159.15 San Juan to Salinas.

TABLE OF CONTENTS

I. SUMMARY

1.0 INTRODUCTION

2.0 GENERAL BACKGROUND

3.0 PROJECT IDENTIFICATION/DESCRIPTION

4.0 METHODS OF BUILDING INSPECTIONS

5.0 SAMPLING METHODS

6.0 INSPECTION RESULTS AND CONCLUSIONS

7.0 CONCLUSIONS

APPENDIX I - AESI Certifications and Accreditations

APPENDIX II - Hazard Assessment

APPENDIX III- Analytical Results

ADY PADAN, PH.D

ADY PADAN, PH.D 1

I. SUMMARY

A survey for Asbestos Containing Materials (ACM) was conducted by Analytical Environmental Services

International (AES International), Inc. for Road PR-3 from

Km 0.0 in San Juan to Km 159.15 in Salinas (not including

Km 46.60 to 48.90).

The inspection was conducted on October 4th, 7th & 8th, 2019 by Elme Rivera, an EQB/AHERA certified asbestos inspector.

The scope of the survey included sampling and physical assessments of suspected ACM from the road section.

Fifteen (15) samples were collected from suspected ACM present. Asbestos fibers were not detected in any of the samples collected and analyzed.

ADY PADAN, PH.D 2

1.0 INTRODUCTION

A survey for Asbestos Containing Materials (ACM) was conducted by Analytical

Environmental Services International, Inc. (AES International) for Road PR-3 from Km

0.0 in San Juan to Km 159.15 in Salinas (not including Km 46.60 to 48.90).

The survey was conducted on October 4th, 7th & 8th, 2019 by Elme Rivera, an

EQB/AHERA certified asbestos building inspector (see Appendix I for credentials).

The inspection was performed based on AHERA protocol, according to the following scenario:

• The road was divided in functional spaces (in Km)

• Visual inspection was performed

• Samples were collected from suspect material

2.0 GENERAL BACKGROUND

Asbestos was used in the construction industry from 1900 to 1989. It is still being used today in various products. The health effects of asbestos have been studied since the

1930's. More health studies have been conducted in asbestos than any other natural substance. The mere presence of asbestos containing materials does not necessary constitute a health hazard. However, when these materials become disturbed from building renovation, maintenance, or other every day activities that allow fibers to be released into the environment, a potential hazard does exist.

The relationship between exposure level and health risk is very complex. Although this relationship is not completely understood, asbestos exposure has been associated with various types of lung diseases including a debilitating lung disease called ASBESTOSIS;

a rare cancer of chest called MESOTHELIOMA; and cancers of the esophagus, stomach, colon and other organs. Asbestosis is not fatal; it is however incurable. One who has it cannot breathe easily and physical activity becomes limited. MESOTHELIOMA is

100% fatal, as there is no cure. These diseases can be directly linked to asbestos because of the mineral particles that can be found in the lining of the lungs and stomach, since the body cannot absorb these minerals. Tests have determined that asbestos can cause cancer, but scientists disagree on the amount of asbestos fibers that must be inhaled to cause cancer. The nose filters out all visible particles. Therefore, only the microscopic fibers are the one who cause the problems.

Studies indicate different health effect resulting from exposure to chrysotile asbestos versus exposure to the amphibole form of asbestos. The later, which include tremolite, amosite, actinolite, anthophyllite and crocidolite have more significant health impact than chrysotile.

ADY PADAN, PH.D 3

Some scientists cite studies concluding that is the size of the fibers deposited in the lungs that result in cancer. Long, thin fibers, greater than 8 microns in length and less than

0.25 microns in diameter show the highest potential of cancer development.

2.1 National Emission Standards for Hazardous Air Pollutants (NESHAP)

The EPA's rules concerning the application, removal, and disposal of ACM, as well as manufacturing, spraying and fabricating of ACM were issued under the asbestos

NESHAP regulation (U.S. EPA National Emission Standards for Hazardous Air

Pollutants, 40 CFR 61 Subpart M, October 30, 1987). The asbestos NESHAP regulation governs asbestos demolition and renovation projects in all facilities. The NESHAP rule usually requires owners or operators to have all friable ACM removed before the building is demolished and may require its removal before renovation. If friable ACM shall be disturbed, the NESHAP rule may require appropriate work practices, or procedures for emission control. The rule states that any ACM, which may become friable, poses a potential hazard that should be addressed.

A revised NESHAP ruling was released on November 20, 1990, effective February 20, 1991 which includes as the responsibility of the owner, or operator, to "prior to the commencement of the demolition or renovation, thoroughly inspect the affected facility or part of the facility where demolition or renovation operation will occur for the presence of asbestos, including Category I and Category II non-friable ACM." (40 CFR, Part 61, National Emission Standards for hazardous Air Pollutants, Asbestos NESHAP

Revision, Final Rule, November 20, 1990).

3.0 PROJECT IDENTIFICATION/DESCRIPTION

4.0 METHODS OF BUILDING INSPECTION

Each sample was classified according to the condition of Asbestos Containing Materials

(ACM) in that location and the potential for material disturbance. All the areas were visually inspected.

5.0 SAMPLING METHODS

Fifteen (15) samples were collected from guardrail rubber spacers.

Project consists of Hurricane Maria Efforts for signing and guardrails designs on the PR-3, kilometers 0.0 to Km 159.15 from San Juan to Salinas, PR.

ADY PADAN, PH.D 4

6.0 INSPECTION RESULTS

Suspected materials were observed during visual inspection. Fifteen (15) samples were collected and analyzed. Results are presented in Appendix III. Asbestos fibers were not found in any of the samples collected and analyzed.

7.0 CONCLUSIONS

A survey for ACM was conducted for Road PR-3 from Km 0 to 159.15, San Juan to

Salinas, PR. The materials surveyed were described above. No ACM were detected.

The ACM survey results do not include materials which are non-accessible, non-visible and may be present behind/inside the walls, or hidden inside the structures. These materials must be assessed at the time of the modernization.

Elme Rivera, EQB Asbestos Inspector

Lic#: ASB-0319-0201-SI

Forma P GC-009

GOBIERNO DE PUERTO RICO

OFICINA DEL GOBERNADOR

JUNTA DE CALIDAD AMBIENTAL

Área de Calidad de Agua

CERTIFICACION DE NO PRESENCIA DE ASBESTO

EN ESTRUCTURAS A DEMOLERSE

(Deberá completarse en letra de molde o impresa)

PGC-_____________________

PARA USO OFICIAL

(Nombre) (Estado Civil) (Municipio)

Dirección Postal__________________________________ _________________________________________________ demolición se encuentra libre de asbesto.

2. La información antes indicada es cierta y correcta.

3. Afirmo y reconozco las consecuencias de incluir y someter información falsa en este documento.

(Municipio)

Firma y Sello del Profesional o

Firma del Inspector de Asbesto registrado por la JCA (Original)

Nota: Ingenieros o Arquitectos deberán someter evidencia de que se encuentra al día en el pago de sus cuotas de colegiación e Inspectores de Asbesto deberán someter evidencia de la tarjeta de registro provista por la JCA.

Dirección Física: Ave. Ponce de León 1308, Carr. Estatal 8838, Sector el Cinco, Río Piedras, PR 00926

Dirección Postal: Apartado 11488, Santurce, PR 00910-

Elme Rivera Casado Yo, ______________________________, mayor de edad,______________, y vecino de__ _______________________ Vega Baja

Vega Baja Lakes Calle 11 L31 00693 (Pueblo) (Zip Code)

Vega Baja

787 724 5788

969 1311 787 722 0220

4. Para que así conste, firmo la presente certificación en ___________________ __________________ de Puerto Rico, Tel. (787) 767-8181 • Fax (787) 767-1962 hoy día ____ de ____________________ de ________

Teléfonos: Residencial (______) ______- ________ Oficina (______) ______- ________ Ext.________ Fax (______) ______- ________

Certifico que:

1. La estructura localizada en__________________________________________________, la cual será objeto de una

San Juan

15 octubre 2019

* Esta certificacion es exclusivamente para las areas muestreadas.

amarin Typewritten text *PR3 from Km 0.0 to Km 159.15 (except 46.60-48.90) from San Juan to Salinas, Puerto Rico.

Appendix I

ACM Inspector Credentials

Appendix II

ANALYTICAL ENVIRONMENTAL SERVICES INTERNATIONAL, INC.

ASBESTOS SAMPLE INSPECTION FORM FOR PHYSICAL & HAZARD ASSESSMENT

Client Name Behar Ybarra & Associates Road: PR3

Project Name: Guardrails along PR3 from Km 0.0 to Km 159.15 (San Juan to Salinas)

Inspection Date: 10/4, 10/7/19 Page: 1 of 3

Homogeneous Material Description Material Asbestos Friability Location Asbestos

Total

Square

AHERA

Assessment Hazard

I.D. Number Material Description

Category Content of Materials Contents Feet of

ACM

Category (1-7,X, None)

Ranking (1-7)

ER1

Rubber Spacer from Guardrail Km

8.8 Misc. No NF Km 0.0 to 159 ND X

ER2

Rubber Spacer from Guardrail Km

15.4 Misc. No NF Km 0.0 to 159 ND X

ER3

Rubber Spacer from Guardrail Km

18.7 Misc. No NF Km 0.0 to 159 ND X

ER4

Rubber Spacer from Guardrail Km

43.4 Misc. No NF Km 0.0 to 159 ND X

ER5

Rubber Spacer from Guardrail Km

51.4 Misc. No NF Km 0.0 to 159 ND X

ER6

Rubber Spacer from Guardrail Km

71.8 Misc. No NF Km 0.0 to 159 ND X

Inspected by: Elme Rivera Date:

Friability: F = friable, NF = nonfriable, X = not applicable (material is non-ACBM)

AHERA Assessment Category: 1 = Damaged of significantly damaged TSI ACBM; 2 = Damaged friable surfacing ACBM; 3 = Significantly damaged friable surfacing ACBM;

4 = Damaged or significantly damaged friable miscellaneous ACBM; 5 = ACBM with potential for damage; 6 = ACBM with potential for significant damage;

7 = Any remaining friable ACBM or friable suspected ACBM; X = Not applicable (material is non-ACBM or non-friable surfacing or miscellaneous materials);

None = No assessment category provided in original inspection.

Hazard Ranking Category: 1 = Significantly damaged; 2 = Damaged and potential of significant damage; 3 = Damaged and potential for damage; 4 = Damaged;

5 = Potential for significant damage; 6 = Potential for damage; 7 = All remaining ACBM

* - See Floor Plans for Location of Functional Spaces; ** - Unless Specified, the Asbestos Type is Chrysotile; ND - None Detected

10/4, 10/7/19

Client Name Behar Ybarra & Associates Road: PR3

Project Name: Guardrails along PR3 from Km 0.0 to Km 159.15 (San Juan to Salinas)

Inspection Date: Page: 2 of 3

Homogeneous Material Description Material Asbestos Friability Location Asbestos

Total

Square

AHERA

Assessment Hazard

I.D. Number Material Description

Category Content of Materials Contents Feet of

ACM

Category (1-7,X, None)

Ranking (1-7)

ER7

Rubber Spacer from Guardrail Km

97.7 Misc. No NF Km 0.0 to 159 ND X

ER8

Rubber Spacer from Guardrail Km

118.2 Misc. No NF Km 0.0 to 159 ND X

ER9

Rubber Spacer from Guardrail Km

128.4 Misc. No NF Km 0.0 to 159 ND X

ER10

Rubber Spacer from Guardrail Km

139.0 Misc. No NF Km 0.0 to 159 ND X

ER11

Rubber Spacer from Guardrail Km

142.0 Misc. No NF Km 0.0 to 159 ND X

ER12

Rubber Spacer from Guardrail Km

153.0 Misc. No NF Km 0.0 to 159 ND X

Inspected by: Elme Rivera Date:

Friability: F = friable, NF = nonfriable, X = not applicable (material is non-ACBM)

AHERA Assessment Category: 1 = Damaged of significantly damaged TSI ACBM; 2 = Damaged friable surfacing ACBM; 3 = Significantly damaged friable surfacing ACBM;

4 = Damaged or significantly damaged friable miscellaneous ACBM; 5 = ACBM with potential for damage; 6 = ACBM with potential for significant damage;

7 = Any remaining friable ACBM or friable suspected ACBM; X = Not applicable (material is non-ACBM or non-friable surfacing or miscellaneous materials);

None = No assessment category provided in original inspection.

Hazard Ranking Category: 1 = Significantly damaged; 2 = Damaged and potential of significant damage; 3 = Damaged and potential for damage; 4 = Damaged;

5 = Potential for significant damage; 6 = Potential for damage; 7 = All remaining ACBM

* - See Floor Plans for Location of Functional Spaces; ** - Unless Specified, the Asbestos Type is Chrysotile; ND - None Detected

10/7, 10/8/19

Client Name Behar Ybarra & Associates Road: PR3

Project Name: Guardrails along PR3 from Km 0.0 to Km 159.15 (San Juan to Salinas)

Inspection Date: Page: 3 of 3

Homogeneous Material Description Material Asbestos Friability Location Asbestos

Total

Square

AHERA

Assessment Hazard

I.D. Number Material Description

Category Content of Materials Contents Feet of

ACM

Category (1-7,X, None)

Ranking (1-7)

ER13

Rubber Spacer from Guardrail Km

154.0 Misc. No NF Km 0.0 to 159 ND X

ER14

Rubber Spacer from Guardrail Km

156.4 Misc. No NF Km 0.0 to 159 ND X

ER15

Rubber Spacer from Guardrail Km

159.0 Misc. No NF Km 0.0 to 159 ND X

Inspected by: Elme Rivera Date:

Friability: F = friable, NF = nonfriable, X = not applicable (material is non-ACBM)

AHERA Assessment Category: 1 = Damaged of significantly damaged TSI ACBM; 2 = Damaged friable surfacing ACBM; 3 = Significantly damaged friable surfacing ACBM;

4 = Damaged or significantly damaged friable miscellaneous ACBM; 5 = ACBM with potential for damage; 6 = ACBM with potential for significant damage;

7 = Any remaining friable ACBM or friable suspected ACBM; X = Not applicable (material is non-ACBM or non-friable surfacing or miscellaneous materials);

None = No assessment category provided in original inspection.

Hazard Ranking Category: 1 = Significantly damaged; 2 = Damaged and potential of significant damage; 3 = Damaged and potential for damage; 4 = Damaged;

5 = Potential for significant damage; 6 = Potential for damage; 7 = All remaining ACBM

* - See Floor Plans for Location of Functional Spaces; ** - Unless Specified, the Asbestos Type is Chrysotile; ND - None Detected

Appendix III

Divisor Appendix I.pdf
Divisor Appendix II.pdf
Divisor Appendix III.pdf

File details come from the government source that posted it. Updated .