4Q1.7-218.pdf
PDF 1 MB Posted
- Solicitation number
- REFCFF81618
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Reference Procedure Screening Form Manual Number Procedure Number Revision
Facility Manager/Program Manager/SRNL R&D Line Manager/or Designees (print / sign / date)
APPROVED FOR USE
Reference Procedure AIM Form (Rev 3-9-2016)
Activity is not complex
– Examples of complex activities: Integration between multiple work groups; tasks that cannot be performed from memory
Steps performed out of sequence, inadvertently omitted, or performed erroneously are recoverable without significant consequence.
– Examples of significant consequence: Errors have an immediate effect and/or significant impact on personnel health and safety or plant or equipment operability; consequences of errors will not be detected and/or corrected prior to the end of the activity and declaration of operability; error in performance will affect the Hazards Analysis (e.g., AHA, JHA, etc.) or USQ that was done on the procedure, and error could result in a new activity that wasn’t analyzed
Procedure does not require documentation of completed steps
– Examples of steps requiring documented completion: TSR; Criticality; QA Hold Point; RPD Action Step;
Independent Verification; Second Person Verification; Packaging and Transportation
Warning, Caution, or ALARA statements within the procedure do not warrant requiring the procedure be in hand
(e.g., procedures do not include hazard controls that are outside of Individual Hazards Analysis (IHA) scope).
If the performance of the procedure meets all of the criteria listed above, then the procedure is properly categorized as a Reference Procedure.
The procedure is technically accurate and can be performed as written
If the procedure cannot be performed as written, then the procedure deficiencies must be corrected prior to release.
The required prerequisite training and/or position qualification are adequate to ensure the user has the skills and knowledge to perform the procedure in a logical sequence to accomplish the task.
APPROVAL AND CONCURRENCE
I have verified that the Reference Procedure is appropriately categorized, technically correct, and personnel are trained to allow performance of the procedure in a logical sequence.
Reviewer (print / sign / date)
CONCURRENCE
Procedure does not require entry of information into the procedure (in any section and/or attachment).
This criterion does not apply if the procedure in review requires completion of a separate data sheet or form.
Categorization
Technical Content
Procedure User Training
Manual: 4Q1.7 Procedure: 218
Revision: 5
INSTRUCTIONS FOR INSPECTION AND REPAIR OF
THE MSA OPTIMAIR MM2K RESPIRATOR EQUIPPED
WITH THE MSA ULTRAVUE FACEPIECE
Effective Date: 05/10/2016 Type-Class: Tech-REF Page: 1 of 25
1.0 INTRODUCTION
1.1 Purpose
To provide instructions for inspection and repair of the MSA MM2K Powered Air Purifying Respirator (PAPR) and the MSA Ultravue facepiece.
1.2 Scope
This procedure applies to the inspection and repair of air purifying MSA MM2K PAPR and the MSA Ultravue facepiece in the Respiratory Equipment Facility (REF) by personnel who are authorized to perform these inspections and repairs.
This is a Reference procedure. The user is not required to have this procedure present while performing the activity.
The following data/round sheets may be utilized in the performance of this procedure:
OSR 4-510, Respiratory Equipment Record and QA Form.
2.0 GENERAL INFORMATION
2.1 Responsibilities
1. The REF Lead is responsible for:
Evaluating results of OSR 4-510 to determine if significant defective items are reported and notifying the Respiratory Protection Program Administrator (RPPA) and Cognizant Quality Function (CQF)
Initiating and responding to Nonconformance reports (NCR) in accordance with Manual 1Q, Procedure 15-1, Control of Nonconforming Items
Defining acceptable condition of rust or discoloration on respirator parts.
2. Respiratory Equipment Facility Personnel are responsible for:
Performing respirator inspections and repairs (excluding the SRS Fire Department respirators)
Completing qualification training as specified in the Job Performance Standard or approved equivalent
Tracking quantity of products inspected, defective, repaired, rejected and new products put in service
Recording information daily on OSR 4-510.
3. The Respiratory Protection Program Administrator (RPPA) is responsible for:
Approving the release of respirators offsite
Responding to issues where significant defects are found.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Revision: 5 Page: 2 of 25
2.2 Information
1. Respirator equipment is worn by workers for protection against airborne hazardous materials and must be maintained in like-new condition to ensure maximum respiratory protection.
2. REF personnel repair air purifying and air supplied respiratory equipment at Building 705-C.
3. Cartridges marked New Cartridge (NC) should be disposed of at the job site.
Any cartridges returned to the REF marked NC are not to be reused and should be returned to the laundry for proper disposal.
4. Medium respirator nosecups are used in small respirators. Medium and large respirator nosecups are used in medium and large respirators.
5. MSA Ultravue MM2K PAPR are available in the following materials and sizes.
Material Description
Silicone
Size: Small, Medium, and Large Size is indicated on a tab inside the lens at the bottom of the lens as well as the color of the lens ring.
Small – Gray lens ring Medium – Black lens ring Large – Gold lens ring Silicone designation on the black colored MSA Ultravue respirator is located above the lens, immediately beneath the MSA logo.
2.2.1 Respiratory Equipment Repair Requirements
CAUTION
The use of substitute parts or altering the respirators voids NIOSH certification.
1. Perform respirator repairs using trained and qualified persons.
2. Repair faulty respirators and inspect all components in accordance with this procedure so that the devices are returned to a like-new condition.
3. Maintain National Institute for Occupational Safety and Health (NIOSH) certification of respirators by only using approved spare parts from the manufacturer of the respirator being repaired.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 3 of 25
2.2.2 Respirators That Cannot Be Repaired
1. Remove respirator from Respiratory Issuance Tracking System (RITS) database.
2. Disassemble MSA Ultravue Respirators that cannot be repaired for needed reusable parts.
3. Store all needed reusable parts for future use.
4. Discard all unneeded and unserviceable parts, including facepieces, in the designated waste container.
2.2.3 Inspection of Unopened Expired Respirators
Respirators returned to the REF unopened and expired will be disassembled and inspected following all steps outlined in this procedure.
2.2.4 Respirators for Offsite Use
Respiratory Protection Program Administrator (RPPA) approval is required to release respirators offsite.
1. Use new respirators only for offsite training, demonstrations, etc.
2. Return these respirators to the Respirator Equipment Facility for cleaning, sanitizing, and processing.
A. If circumstances require recycled respirators to be used offsite for a similar purpose, then contact Radiological Protection Department to perform an unrestricted use survey before release.
2.2.5 MM2K PAPR Description
1. Certified by NIOSH, the OptimAir MM2K PAPR consists of the following components:
motor/blower battery support belt charger with cable power cable facepiece cartridge sparkguard cover for cutting, grinding and welding (upon request only) cartridge cartridge thread sleeve (upon request only)
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 4 of 25
2.2.5 MM2K PAPR Description, (cont.)
2. The OptimAir MM2K PAPR uses a mask mounted motor/blower to draw air through a cartridge, which removes the particulate contaminant, and provides a constant flow of respirable air directly to the facepiece. The MM2K PAPR is available with High Efficiency Particulate Air (HEPA) cartridge only. The REF will be servicing the motor/blower, facepiece and cartridge. The operating facility will be responsible for servicing the battery, support belt, charger with cable, and power cable. The REF may service all components, if requested.
2.2.6 MM2K PAPR Battery
1. The OptimAir MM2K PAPR uses a nickel metal hydride battery (see Figure 8.3). The battery is encased in a hard plastic case and is water resistant and is designed for easy shower decontamination. The ON/OFF toggle switch is located on the top of the battery. There are loops on the back of the battery case for mounting onto a belt. The battery is charged with a dual rate smart charger.
2. The battery should be stored in temperature range between 50 to 85 degrees Fahrenheit when not in use.
3. The MM2K PAPR battery charger, shown as Figure 8.3, uses one light-emitting diode (LED). When the battery is charging, the LED will be Red.
The battery can stay connected to the charger until it is needed.
LED Signaling
Condition LED Indication Rapid Charge Red
Charge Complete Green Charge Pending Amber Charge Failure Red Flash
No AC or No Battery OFF
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 5 of 25
3.0 PRECAUTIONS AND LIMITATIONS
3.1 Safety
1. When using hand tools such as a screwdriver, a leather or puncture resistant glove shall be worn on the hand opposite of the hand holding the tool.
2. The use of substitute parts or altering the respirators voids NIOSH certification. Approved spare parts from the manufacturer of the respirator being repaired must be used to maintain NIOSH certification of respirators.
3. Do not use compressed air for cleaning purposes except where reduced to 30 pounds per square inch gage (psig) or less and appropriate personal protection equipment (PPE) is used. Never use compressed air to remove dust or other residue from an employee's body or to blow down an employee’s clothing.
4. Safety glasses with side shields are required when using airblow gun.
5. Read and obey all shop safety postings.
6. When handling material, wear proper PPE as required.
7. Review proper lifting techniques outlined in Manual 8Q, Procedure 12, General Site Safety Requirements.
8. Additional hazard analysis may be required to ensure that facility/job specific hazards are identified and that the appropriate actions are taken to eliminate/mitigate the identified hazard(s).
4.0 PREREQUISITES
4.1 Planning and Coordination
1. OBTAIN OSR 4-510 to document information.
5.0 PERFORMANCE
5.1 Respirator
1. INSPECT AND EXAMINE facepiece for water spots, makeup and dirt.
2. WIPE off any water spots, makeup or light dirt from facepiece using a damp cloth with water.
3. DRY damp areas with a lint free dry cloth.
4. IF any respirators have excessive makeup or heavy dirt, THEN
RETURN them to the laundry facility for rewashing.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 6 of 25
5.1 Respirator, (cont.)
5. INSPECT AND EXAMINE the facepiece for the issues below by gently stretching, pulling, and pressing the material in different directions.
A. ENSURE that careful examination is conducted in the area around the metal clamp and speaking diaphragm housing.
B. PROCEED to appropriate section of procedure for further instruction as needed.
missing or illegible respirator barcode (alpha numeric identifier and barcode) cracks, tears, holes, distortion inflexibility cracked or badly scratched lens incorrectly mounted lens cracked or broken filter cartridge receptacle, badly worn threads, or missing gaskets missing, deformed or damaged inlet valve, and spider gasket
5.1.1 Barcode
1. IF respirator alpha numeric identifier and barcode is illegible or if the barcode is missing, THEN
REPLACE OR ADD a new barcode tag using the key ring tool to open the key ring.
A. With key ring open, REMOVE illegible tag and/or SLIDE a new tag onto the ring until the tag is secure.
B. ATTACH the key ring to the D-ring on the lower right harness buckle.
See location of D-ring in Figure 8.1.
C. ADD new barcode number to RITS database.
5.1.2 Facepiece
1. IF cracks, tears, holes, distortion or inflexibility are found in the facepiece itself, THEN
A. REMOVE from RITS database.
B. DISASSEMBLE the facepiece
C. RETAIN any needed serviceable parts for future use.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 7 of 25
5.1.3 Lens
1. IF cracked or badly scratched lens is found, THEN
A. MARK the lens with masking tape to alert the respirator repair person that the lens needs replacing.
B. PLACE the respirator in the bin labeled “TO BE REPAIRED”.
C. PROCEED to Step 3 if replacing.
2. IF the lens is found to be incorrectly mounted, THEN
A. MARK the lens with masking tape to alert the respirator repair person that the lens needs realigning.
B. PLACE the respirator in the bin labeled “TO BE REPAIRED”.
C. PROCEED to Step 3 if replacing.
3. IF lens needs replacing, THEN
A. WHEN installing screws, THEN
ENSURE that head of screw is opposite of nut. Some lens rings require a nut be placed in the lens ring. Some lens rings have a nut built into the lens ring. The nut can be viewed by the metal on one end of the lens ring for those that are built in. See Figure 8.1, Page 1 of 2.
B. REMOVE the screws on both sides of the lens ring, AND
PULL lens rings away from lens.
C. PEEL back the rubber holding the lens in place, AND
REMOVE lens.
D. WIPE rubber groove with damp cloth or use 30 psig of air to remove dirt in the groove.
E. OBTAIN replacement lens.
F. PLACE lens inside rubber groove, AND
SECURE by running fingers around rubber and lens.
G. OBTAIN the appropriate lens ring for the size respirator being repaired.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 8 of 25
5.1.3 Lens, (cont.)
Step 3, (cont.)
H. PLACE lens ring over rubber and lens, AND
CENTER lens, THEN
SECURE using screws.
5.2 Head Harness
1. INSPECT AND EXAMINE the head harness for:
breaks loss of elasticity broken, malfunctioning, or rust on buckles and attachments excessively worn serrations on the head harness that might permit slippage dry rotting of the rubber
2. IF any defects are found on the head harness, THEN
REPLACE head harness.
5.3 Exhalation Flapper Valve and Exhalation Valve Body
1. REMOVE the exhalation valve cover.
2. INSPECT AND EXAMINE the exhalation flapper valve and exhalation valve body for the following:
foreign materials, such as detergent residue, dust particles, lint, or hair between valve and valve seat cracks, tears, or distortion of the valve improper insertion of the valve body in the facepiece cracks, breaks, or chips in the valve body, particularly on the sealing surface of the seat improper installation of the valve in the exhalation valve body
3. IF foreign materials are found, THEN
A. REMOVE foreign materials.
B. ENSURE valve seats.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 9 of 25
5.3 Exhalation Flapper Valve and Exhalation Valve Body, (cont.)
4. IF foreign materials cannot be removed, THEN
A. REMOVE the flapper valve.
B. REPLACE flapper valve.
5. IF crack, tear, or distortion of the flapper valve is discovered, THEN
A. REMOVE flapper valve.
B. REPLACE flapper valve.
6. IF exhalation flapper valve is not properly inserted in the exhalation valve body, THEN
A. PULL exhalation flapper valve tab on the inside of facepiece.
B. ENSURE flapper valve sits flush against the exhalation valve body after release of the tab.
7. IF the exhalation valve body has cracks, breaks, or chips, THEN
A. REMOVE body by pulling facepiece in one direction and pushing body inward into the facepiece.
B. OBTAIN replacement exhalation valve body.
C. OPEN hole left by removed exhalation valve body using the seat installation tool (see Figure 8.2).
D. INSERT replacement exhalation valve body.
E. IF the exhalation valve body is not properly inserted into the facepiece, THEN
REALIGN using fingers. The exhalation valve body is oblong shaped with the oblong body positioned horizontally in the facepiece.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 10 of 25
5.4 Inlet Valve, Inlet Valve Spider, Inlet Assembly, Speaking Diaphragm Housing, O-Ring, Speaking Diaphragm and Retainer Ring
1. INSPECT the inlet valve and inlet valve spider in the facepiece inlet assembly.
2. IF the inlet valve spider and/or the inlet valve is damaged or deformed, THEN
A. REMOVE by pulling inlet valve spider and inlet valve from inlet assembly.
B. REPLACE inlet valve and inlet valve spider by installing the inlet valve first then installing inlet valve spider into inlet assembly.
C. PRESS inlet valve spider into place, using fingers, until it is seated flat. The inlet valve spider has a groove around the entire base. This groove should be positioned downward into the facepiece.
NOTE
Inlet valve will always be under the inlet valve spider.
3. IF the inlet assembly is damaged, THEN
A. REMOVE clamp.
B. REMOVE inlet assembly from respirator.
C. OBTAIN replacement inlet assembly.
4. IF suspected the speaking diaphragm, O-ring, or retainer ring are damaged, THEN
A. DISASSEMBLE speaking diaphragm housing.
B. REMOVE retainer ring by turning counter clockwise.
C. INSPECT retainer ring for damage.
D. REMOVE speaking diaphragm, O-ring, AND
INSPECT for damage.
E. IF any damage is detected, THEN
1) REPLACE damaged part, AND
REASSEMBLE. See Appendix 8.1.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 11 of 25
5.4 Inlet Valve, Inlet Valve Spider, Inlet Assembly, Speaking Diaphragm Housing, O-Ring, Speaking Diaphragm and Retainer Ring, (cont.)
NOTE
Clamp screw should be placed at either the four o’clock or eight o’clock position and not overtightened.
5. INSERT inlet assembly into facepiece, AND
TIGHTEN the clamp.
5.5 Nosecup
1. INSPECT the nosecup valves and vale seats for damage, AND
ENSURE the inhalation valve discs and valves seats are in place.
2. IF nosecup is damaged, THEN
REPLACE parts as necessary.
3. INSTALL nosecup by fitting the circular position of the nosecup onto the retainer ring of the speaking diaphragm housing inside the facepiece.
4. ENSURE the nosecup is centered in the facepiece.
5.6 Removal of Excess Debris
NOTE
Use of safety glasses with side shields is required when using airblow gun.
1. ENSURE the pressure regulator to the airblow gun is set at 30 psig.
2. HOLD airblow gun approximately three inches from the inhalation valve when blowing respirators out to ensure that the inhalation valve is not dislodged.
3. BLOW each respirator out using the airblow gun for any:
dust lint detergent hair or other foreign material in facepiece.
4. WHEN blowing respirators out, THEN
ENSURE the inlet valve is in place and is not stuck.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 12 of 25
5.6 Removal of Excess Debris, (cont.)
5. ENSURE the exhalation flapper valve is in place and not stuck to the exhalation valve body.
NOTE
Respirators are returned from the Laundry Facility with the exhalation valve covers removed.
CAUTION
Use care when probing not to damage inlet valve.
6. INSPECT exhalation valve cover for damage.
7. IF damage is found, THEN
REPLACE exhalation valve cover.
8. CHECK tightness of lens screws and speaking diaphragm clamp.
9. Respirator Technician: REQUEST peer to perform the following:
A. USE a light probing device to verify that the inlet valve and inlet valve spider are in place and seated flat by visually viewing and gently probing the inlet valve of each respirator.
B. WHEN peer review is complete, THEN
Respirator technician may INSTALL the tested motor/blower and cartridge per Sections 5.9 and 5.10.
10. DISPOSE of any damaged exhalation flapper valves, bodies, and covers in the appropriate waste container.
5.7 MM2K PAPR Battery
1. IF battery has been stored in a “fully charged” condition after one week, THEN
CHARGE the battery until a full charge is indicated.
2. IF battery falls to the floor, THEN
INSPECT case for cracks or loose female connector.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 13 of 25
5.7 MM2K PAPR Battery, (cont.)
3. IF motor/blower no longer operates after battery impact, THEN
REPLACE the battery.
4. PLACE damaged battery in designated waste container.
5.7.1 Charging Battery
! WARNING !
Do not charge battery where there are explosive concentrations of combustible gases, vapors, or mists. An explosion or fire can result. Replace the charger if the cord is damaged or worn, or if the case is cracked or distorted. Do not use a damaged charger.
1. LINE-UP the key in the charge cable plug with the slot in the female connector on the battery.
2. PUSH the plug into the female connector, AND
TURN the ring 1/4 turn to secure it.
3. ENSURE secure connection of plug by slightly tugging on the female connector. Do not tug on cable wire.
4. PLUG the charger into a standard alternating current (AC) outlet.
5. CHARGE the battery until a full charge is indicated on charger.
5.7.2 Charger Description
1. IF the LED is Amber, the battery is not at the proper temperature, THEN
OBSERVE the charging will start when the battery reaches the optimum charging temperature of 35 to 100 degrees Fahrenheit.
2. IF the LED is flashing Red (indicating there is a failure), THEN
A. DISCONNECT battery.
B. UNPLUG charger.
C. PLUG charger back into outlet.
D. RECONNECT battery to reset charger.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 14 of 25
5.7.2 Charger Description, (cont.)
3. IF LED flashes RED during any part of the charge, after it has been reset, THEN
REMOVE the battery from service, AND
PLACE battery in designated waste container.
5.7.3 Discharging Battery
1. DISCHARGE each battery monthly as follows:
A. FULLY CHARGE the battery.
B. CONNECT battery, power cable and motor/blower.
C. TURN power on.
D. RUN motor/blower until battery is fully discharged (motor/blower has stopped).
E. FULLY CHARGE the battery.
2. PLACE a label with discharge date on the battery.
3. RECORD battery charges and monthly discharges. See example form shown as Appendix 8.2.
5.8 Inspect Cartridges
1. EXAMINE the cartridges for the following types of damage:
excess glue on the inside of cartridge at threaded end cartridge separation stress (evidenced by dye migration)
2. ENSURE that the cartridge label is legible.
3. DISCARD the faulty or illegible cartridges in the designated waste container.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 15 of 25
5.9 Inspect MM2K PAPR Motor/Blower
1. INSPECT motor/blower and coupling nut for cracks and broken areas.
2. IF cracks or broken areas are found, THEN
DISCARD motor/blower in designated waste container.
3. ENSURE gasket is present inside motor/blower.
A. IF gasket is missing, THEN
INSTALL gasket.
4. REMOVE AND INSPECT gasket for tears, cuts, and deformation.
A. IF no damage is detected, THEN
REINSTALL gasket.
! WARNING !
Do NOT over tighten cartridge.
5. INSTALL the cartridge by holding the motor/blower with one hand and threading the cartridge with the other and hand tighten as follows:
A. THREAD cartridge until cartridge engages with the cartridge gasket.
B. CONTINUE to thread cartridge 1/4 turn.
NOTE
Cartridges marked “NC” should be disposed of at the job site. Any cartridges returned to the REF marked “NC” are not to be reused and should be returned to the laundry for proper disposal.
6. IF the MM2K PAPR is for a non-radiological job, THEN
INSTALL new HEPA cartridges marked NC on the cartridge.
7. OBTAIN fully charged MM2K battery.
8. LINE-UP the key on the power cable plug with the slot in the female connector on the battery.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 16 of 25
5.9 Inspect MM2K PAPR Motor/Blower, (cont.)
9. PUSH the plug into the female connector, AND
TURN the ring 1/4 turn to secure it.
A. ENSURE secure connection of plug by slightly tugging on the female connector.
10. LINE-UP the key on the power cable plug with the slot in the female connector on the motor/blower.
11. PUSH the plug into the female connector, AND
TURN the ring 1/4 turn to secure it.
A. ENSURE secure connection of plug by slightly tugging on the female connector.
12. THREAD mask mounted adapter (part number 491046) to Flow-Check Meter (part number 487995), THEN
THREAD the motor/blower into the mask mounted adapter.
13. TURN battery power ON.
14. LISTEN for unusual motor/blower sound.
A. IF unusual sound is heard, THEN
REPORT to REF LEAD.
CAUTION
Do NOT block the vertical tube slots or filter during the test. This will result in inaccurate readings.
15. TILT the Flow-Check Meter to the left or right.
A. RETURN Flow-Check Meter to the vertical position
B. READ the position of the ball.
Ball must be above the lower line marked “Entire ball must be above this line for respirators with full facepieces”
16. IF the motor/blower meets the minimum flow requirements, THEN
PROCEED for use.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 17 of 25
5.9 Inspect MM2K PAPR Motor/Blower, (cont.)
17. IF the motor/blower does not meet the minimum flow requirements, THEN
A. REMOVE the motor/blower from service.
B. NOTIFY the REF Lead.
18. TURN battery OFF.
19. DISCONNECT the power cable from the motor/blower and the battery by applying a 1/4 turn counter clockwise, AND
REMOVE the plug.
20. PLACE the power cable and the battery in the facility designated location.
21. DISCONNECT the Mask Mounted Adapter and Flow Check Meter from motor/blower.
22. ATTACH the motor/blower to an inspected Ultravue facepiece by positioning the motor/blower so that the power cable connection is on the left side of the facepiece.
23. THREAD the motor/blower coupling nut into the facepiece until resistance is encountered.
24. CONTINUE tightening the coupling nut an additional 60 degrees (the distance of two notches on the coupling nut) into the facepiece.
25. MOVE respirators to the testing area to await Leakage Testing on the TSI Respirator Leak Tester per Procedure Manual 4Q1.7, Procedure 215, Operation of TSI Filter Tester 8127 and TSI 8119 Respirator Leak Tester.
5.10 Cartridge Thread Sleeve for OptiFilter XL P100 PAPR Cartridge
NOTE
The purpose of the cartridge thread sleeve is to increase the torque required to unthread the cartridge. It is intended for users working in enclosed areas that may subject the cartridge to impact.
1. IF requested by operating facility, THEN
INSTALL the Cartridge Thread Sleeve.
2. STRETCH the thread sleeve over the cartridge threads as shown in Figure 8.4.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 18 of 25
5.10 Cartridge Thread Sleeve for OptiFilter XL P100 PAPR Cartridge, (cont.)
3. PUSH the thread sleeve down to expose the end of the cartridge threads as shown in Figure 8.4.
4. FOLLOW Step 5.9.5 to install cartridge. When properly installed, the thread sleeve will be compressed between the cartridge body and the motor/blower.
5.11 Post Performance Activities
1. FORWARD completed OSR 4-510 forms to the REF Lead for filing.
6.0 REFERENCES
ANSI/ASQ Z1.4-2003, Sampling Procedure and Table for Inspection by Attributes
Hazard Analysis INF-20045
1Q, Quality Assurance, QAP 15-1, Control of Nonconforming Items
4Q1.7, Procedure 215, Operation of TSI Filter Tester 8127 and TSI 8119 Respirator Leak Tester
8Q, Employee Safety, Procedure 12, General Site Safety Requirements
OSR 4-510, Respirator Equipment Record and QA Form
7.0 RECORDS
Records generated as a result of implementing this procedure are maintained in accordance with Manual 1B, Procedure 3.31, Records Management.
OSR 4-510, Respirator Equipment Record and QA Form
8.0 ATTACHMENTS
Figure 8.1 Examples of Respirator Lens Rings and D-Ring for Barcode
Figure 8.2 Photo of the Seat Installation Tool
Figure 8.3 Photo of MSA Battery and Charger
Figure 8.4 Cartridge Thread Sleeve Information
Appendix 8.1 Assembly/Parts Diagram
Appendix 8.2 Example of Monthly Discharge/Recharge of PAPR Batteries Form (Sample)
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 19 of 25
FIGURE 8.1
Examples of Respirator Lens Rings and D-Ring for Barcode
D-Ring Respirator with nut inserted
D-Ring Respirator without visible nut
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 20 of 25
FIGURE 8.1
Examples of Respirator Lens Rings and D-Ring for Barcode
Respirator lens ring with built-in nut. The screw is inserted from other side of lens ring.
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 21 of 25
FIGURE 8.2
Photo of the Seat Installation Tool
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 22 of 25
FIGURE 8.3
Photo of MSA Battery and Charger
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 23 of 25
FIGURE 8.4
Cartridge Thread Sleeve Information
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 24 of 25
APPENDIX 8.1
Assembly/Parts Diagram
Instructions for Inspection and Repair of the MSA Optimair MM2K Respirator Equipped with the MSA Ultravue Facepiece
Page: 25 of 25
APPENDIX 8.2
Example of Monthly Discharge/Recharge of PAPR Batteries Form (Sample)
Monthly Discharge/Recharge of PAPR Batteries
Date Battery Serial
Number
Start Time for
Recharge
Start Time for
Discharge
Stop Time for
Discharge
Recharge after
Discharge
Verify Battery Fully
Charged
| 4Q1.7-218 Rev 5 Form |
| 4Q1.7-218 Rev 5 |
| Manual Number: 4Q1.7 | |
| Procedure Number: 218 | |
| Revision: 5 | |
| Check Box1: Yes | |
| Check Box2: Yes | |
| Check Box3: Yes | |
| 2016-05-11T08:43:55-0400 | |
| F1571 |
| 2016-05-23T12:02:19-0400 | |
| Kirk Morrell |
File details come from the government source that posted it.