The related federal contract opportunity is a solicitation for FY22 drydock repairs to the NOAA Ship Ronald H. Brown. The solicitation is issued by the Department of Commerce National Oceanic and Atmospheric Administration. It provides an opportunity for contractors to bid on repair work during the vessel's scheduled drydocking. The closure list may inform the scope of work for repairs and inspections of the ventilation system components.
View the file
Other files
Show 40 more
Latest 50 of 81 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOAA Ship Ronald H. Brown Ventilation Closure List
No. Location Frame Approx. Size (inches) Service Label Notes
04 DECK
1 04 Port 58 5 x 15 Radio Room Natural Exhaust FIRE CLOSURE N.E. FM RADIO CHART RM Dwg. 512-6932954 Detail 21A
03 DECK
2 03 Starboard 71 15 x 15 AC Supply 03-69-1 FIRE CLOSURE O.A. TO A/C 03-69-1 Dwg. 512-6932954 Detail 39B
02 DECK
3 02 Forward Port 16 24 x 24 Bio Lab Exhaust VENT EXHAUST EXHAUST FAN 1-19-2 BIO-ANA-CLEAN-LAB
4 02 Forward Port Inboard 16 24 x 24 Bowthruster Room Exhaust VENT EXHAUST NATURAL EXHAUST BT AND MG ROOM
5 02 Forward Centerline 16 30 x 32 Bowthruster Room Supply Missing
6 02 Starboard 47 30 x 20 Galley Exhaust FIRE CLOSURE EXH FM GALLEY, FIRE CLOSURE E02-48-1 Dwg. 512-6932954 Detail 9C
7 02 Starboard 48 6 in. round Paint Locker 02-46-1 Natural Exhaust FIRE CLOSURE N.E. DECK LKR
Dwg. 512-6932954 Detail 16A (stbd bulkhead of Paint Locker)
8 02 Starboard 49 6 in. round Paint Locker 02-46-1 Natural Supply FIRE CLOSURE N.S. DECK LKR (aft bulkhead of Paint Locker)
9 02 Starboard 67 24 x 24 AC Supply 02-64-1 FIRE CLOSURE E 02-67-1
10 02 Starboard 69.5 12 in. round Aft Paint Locker 02-64-3 Exhaust FIRE CLOSURE E02-68-1
11 02 Starboard 71 6 x 12 Paint Locker 02-64-3 Natural Supply FIRE CLOSURE N.S. TO PAINT STORES
12 02 Starboard (near CL) 73 24 x 33 Exh System 02-71-1 EXHAUST SYSTEM 02-71-1, FIRE CLOSURE E02-71-1
13 02 Port 92.5 8 x 15
Science Storeroom #2 (Exercise Room) Supply 2-90-1
(Double Intake) - Forward End Missing Dwg. 512-6932959 Detail 22E
14 02 Port 92.5 8 x 15
Science Storeroom #2 (Exercise Room) Supply 2-90-1
(Double Intake) - Aft End Missing Dwg. 512-6932959 Detail 22E
01 DECK
15 01 Deck, Bow, Forward Starboard 1 6 in. round Bosn Locker Supply FIRE CLOSURE S1-1-1 Gooseneck
16 01 Deck, Bow, Forward Port 1 6 in. round Bosn Locker Natural Exhaust FIRE CLOSURE P1-1-1 Gooseneck
17 01 Deck Port 16 6 x 10 Deck Locker 01-16-4 Natural Supply Missing Forward Bulkhead
18 01 Deck Port 18 6 x 10 Deck Locker 01-16-4 Natural Exhaust FIRE CLOSURE N.E. FM DECK LKR
Dwg. 512-6932953 Detail 18C (Port
Bulkhead Above Door)
19 01 Deck Starboard 24 9 in. round Scientific Office Natural Exhaust FIRE CLOSURE SCIENTIFIC OFFICE Dwg. 512-6932953 Detail 18A
20 01 Deck Port 26 20 x 16 Bio Analytical Lab Supply Missing
Dwg. 512-6932953 Detail 20D (Tall
Vent - Needs Ladder to Maintain)
21 01 Deck Port 47 9 in. round Computer Lab Natural Exhaust FIRE CLOSURE N.E. FM ELECT COMP LAB Dwg. 512-6932953 Detail 18A
22 01 Deck Starboard 64 12 x 12 Pantry Natural Supply FIRE CLOSURE N.S. TO PANTRY
23 01 Deck Starboard 67 6 in. round Deck Locker 01-67-1 Natural Supply FIRE CLOSURE N.S. DK LKR 01-67-1
24 01 Deck Starboard 70 6 in. round Deck Locker 01-67-1 Natural Exhaust FIRE CLOSURE N.E. DK LKR 01-067-1
25 01 Deck Port 70 9 in. round AC Supply 1-70-2 FIRE CLOSURE O.A. TO AC 1-70-2
26 01 Deck Port, Aft of Incinerator Room 96 12 x 18 ? Unknown Missing
27 01 Deck Port, Inboard 99 36 x 36 Winch Room Supply S2-101-2, Inboard FIRE CLOSURE WINCH RM S2-101-2 Dwg. 512-6932959 Detail 7A
28 01 Deck Port, Outboard 99 36 x 45 Winch Room Supply S2-101-2, Outboard FIRE CLOSURE WINCH RM S2-101-2 Dwg. 512-6932959 Detail 7A
MAIN DECK
29 Main Deck Starboard 64 (Outboard) 46 x 12 Main Lab Supply Missing Dwg. 512-6932955 Detail 23F
30 Main Deck Starboard 64 (Inboard) 26 x 13 Main Deck AC Supply
FIRE CLOSURE OA TO AC 1-42-1 & 2-26-1
W.T. CLOSURE R.A. AC 2-26-1 Dwg. 512-6932955 Detail 23F
31 Main Deck Starboard 67 15 x 15 Haz Mat Locker Natural Supply FIRE CLOSURE N.S. TO HAZ MTL LKR Dwg. 512-6932955 Detail 23F
32 Main Deck Starboard 70 8 x 15 Haz Mat Locker Exhaust FIRE CLOSURE EXH SYS 1-70-1
33 Main Deck Starboard 74 6 in. round Dive Locker Natural Supply
FIRE CLOSURE N.S. TO DIVE LKR
DIVE COMPRESSOR AIR INTAKE NO SMOKING
34 Main Deck Starboard 75 18 x 24 Wet Lab Natural Exhaust FIRE CLOSURE NAT EXH FM WET LAB
35 Main Deck Starboard 87 15 x 30 Staging Bay Supply FIRE CLOSURE T.A. 1-86-1
Dwg. 512-6932955 Detail 22A (high vent - can't be reached from deck)
36 Main Deck Starboard 96 18 x 13 Staging Bay Exhaust FIRE CLOSURE T5 FM STAGING BAY
Dwg. 512-6932955 Detail 23F (high vent - can't be reached from deck)
37 Main Deck Starboard 97 11 in. round Scientific Storeroom #2 (Exercise Room) Exhaust Missing
38 Main Deck Starboard 107 20 x 16 Winch Room Natural Exhaust
W.T. CLOSURE S2-90-1 NATURAL
EXHAUST FM WINCH ROOM On Crane Foundation, Forward
39 Main Deck Starboard 108 15 x 30 Winch Room Natural Exhaust Label only by forward closure, Add here On Crane Foundation, Stbd Fwd
40 Main Deck Starboard 110 12 x 12 Winch Room Natural Exhaust Label only by forward closure, Add here On Crane Foundation, Stbd Aft
File details come from the government source that posted it. Updated .